Photoshop CS5: how many files can be opened at once?

I've just tried to open about 400 jpg's in Photoshop CS5, as I needed to crop them to the best ratio for display on my iPod Touch, and I got an error message saying I'd tried to open too many images at once, and it stopped at about 200.
My system is a Win7 Pro 64Bit, 3.4GHz i7 machine, with 16GB RAM, and I thought actions like this were driven by the amount of system resource available, but Photoshop seems to have an internal limit, regardless of the resources.
Has anyone else come across this apparent limit, and is there a way 'round it?
Thanks
Paul

In that case if a center crop will do you can download my crafting actions package. It contains a plug-in script that I wrote based on Adobe plug-in script Fit Image its name is AspectRatioSelection you can record using it in an action set its dialog to have it set a new selection that is a rectangle with a aspect ratio 3 2 that is centered and not feathered.  This script will select a 3;2 center selection for lanscape images and a 2:3 selection for Portrait images.  When the action is played the diaqlog will not show for the plug-in will record the settings you used when you recorded the action into the actions step.  These setting will be passed to the script when the action is played and the script will not display its dialog unless you turn on the dialog in the action step.  Once this setp is recorded follow it with a Image Crop step.  Once you have recorded this two setp action you can run the Image processor set its dialog to run this action and heve it save and resize the crop to fit 1920x1920 or you could include a Fit Image step in the action after the Image crop step and set the Fit Image dialog  width and height to 1920. You will find Fit image and AspectRatioSelection under menu File>Automate>...... You will also find Imahe Processor Pro there if you download it from Russell Browns web site.
If a center crop will not do for you add an additional step to the action to make it interactive by adding an interactive transform selection after the aspectratioselection step.  The step need to be recorded with a 180 degree rotation and  have its dialog turned on and you will need to hold the shift or shift+alt keys down and use a cornor point as you transform the 3:2 selection to constrain the selection to have the same 3:2 aspect ratio.
Crafting Actions Package Contains
Action Actions Palette Tips.txt
Action Creation Guidelines.txt
Action Dealing with Image Size.txt
Action Enhanced via Scripted Photoshop Functions.txt
CraftedActions.atn Sample Action set includes an example Watermarking action
Sample Actions.txt Photoshop CraftedActions set saved as a text file.
12 Scripts for actions
Download

Similar Messages

  • How many databases can be opened simultaneously in a single file?

    To all:
    I don't known how many databases can be opened simultaneously in a single file. After my application open 499 databases in a single file simultaneously, DB->open return error 12.(can not allocate memory ?).
    How can i do ? Thanks.

    I found it:
    Berkeley DB Reference Guide:
    Locking Subsystem
         PrevRefNext
    Configuring locking: sizing the system
    The lock system is sized using the following three methods:
    DB_ENV->set_lk_max_locks
    DB_ENV->set_lk_max_lockers
    DB_ENV->set_lk_max_objects
    The DB_ENV->set_lk_max_locks, DB_ENV->set_lk_max_lockers, and DB_ENV->set_lk_max_objects methods specify the maximum number of locks, lockers, and locked objects supported by the lock subsystem, respectively. The maximum number of locks is the number of locks that can be simultaneously requested in the system. The maximum number of lockers is the number of lockers that can simultaneously request locks in the system. The maximum number of lock objects is the number of objects that can simultaneously be locked in the system. Selecting appropriate values requires an understanding of your application and its databases. If the values are too small, requests for locks in an application will fail. If the values are too large, the locking subsystem will consume more resources than is necessary. It is better to err in the direction of allocating too many locks, lockers, and objects because increasing the number of locks does not require large amounts of additional resources. The default values are 1000 of each type of object.
    When configuring a Berkeley DB Concurrent Data Store application, the number of lock objects needed is two per open database (one for the database lock, and one for the cursor lock when the DB_CDB_ALLDB option is not specified). The number of locks needed is one per open database handle plus one per simultaneous cursor or non-cursor operation.
    Configuring a Berkeley DB Transactional Data Store application is more complicated. The recommended algorithm for selecting the maximum number of locks, lockers, and lock objects is to run the application under stressful conditions and then review the lock system's statistics to determine the maximum number of locks, lockers, and lock objects that were used. Then, double these values for safety. However, in some large applications, finer granularity of control is necessary in order to minimize the size of the Lock subsystem.
    The maximum number of lockers can be estimated as follows:
    * If the database environment is using transactions, the maximum number of lockers can be estimated by adding the number of simultaneously active non-transactional cursors open database handles to the number of simultaneously active transactions and child transactions (where a child transaction is active until it commits or aborts, not until its parent commits or aborts).
    * If the database environment is not using transactions, the maximum number of lockers can be estimated by adding the number of simultaneously active non-transactional cursors and open database handles to the number of simultaneous non-cursor operations.
    The maximum number of lock objects needed for a single database operation can be estimated as follows:
    * For Btree and Recno access methods, you will need one lock object per level of the database tree, at a minimum. (Unless keys are quite large with respect to the page size, neither Recno nor Btree database trees should ever be deeper than five levels.) Then, you will need one lock object for each leaf page of the database tree that will be simultaneously accessed.
    * For the Queue access method, you will need one lock object per record that is simultaneously accessed. To this, add one lock object per page that will be simultaneously accessed. (Because the Queue access method uses fixed-length records and the database page size is known, it is possible to calculate the number of pages -- and, therefore, the lock objects -- required.) Deleted records skipped by a DB_NEXT or DB_PREV operation do not require a separate lock object. Further, if your application is using transactions, no database operation will ever use more than three lock objects at any time.
    * For the Hash access method, you only need a single lock object.
    For all access methods, you should then add an additional lock object per database for the database's metadata page.
    Note that transactions accumulate locks over the transaction lifetime, and the lock objects required by a single transaction is the total lock objects required by all of the database operations in the transaction. However, a database page (or record, in the case of the Queue access method), that is accessed multiple times within a transaction only requires a single lock object for the entire transaction.
    The maximum number of locks required by an application cannot be easily estimated. It is possible to calculate a maximum number of locks by multiplying the maximum number of lockers, times the maximum number of lock objects, times two (two for the two possible lock modes for each object, read and write). However, this is a pessimal value, and real applications are unlikely to actually need that many locks. Reviewing the Lock subsystem statistics is the best way to determine this value.
    I created DB_CONFIG file, and add three lines:
    set_lk_max_locks 20000
    set_lk_max_lockers 20000
    set_lk_max_objects 20000
    As the default values are 1000 of each type of object, my applicaton open 499 database(except internal database) simultaneously(CDB modal) . After changed parameters, my application opend above 6000 database.

  • With one package of Adobe Creative Suite 2 and the upgrade CS5 how many computers can use it?

    With one package of Adobe Creative Suite 2 and the upgrade CS5 how many computers can use it?

    You have 2 activations and no more.
    Mylenium

  • How many meetings can be opened by one account at the same time?

    I've tried Adobe Connect trial version.
    There are few questions about the product.
    1.How many meetings can be opened by one account at the same time?
       I could open 9meetings at the same time using other PCs. What is the limit?
    2.What is the maximum of students in a meeting?
       I'm thinking of buying monthly/Individual product.
    3.The meeting never end even though host is out of it. But we want to control.
       Can host close a meeting so that all participants are out of the session?
    Thanks for your attention.

    This depends on your licensing.
    If you are using a Named Host license, then you can open one meeting at a time. If other members of the Meeting Host group are present in a room, then it should allow you to have multiple rooms open, one for each Meeting Host licensing being used.
    If you are using the Concurrent Learner license, then each meeting you join uses a different licenses, so as long as you have concurrent seats available, you can open as many rooms as you want/need.
    Maximum number of attendees (students) would be your room's concurrent maximum, less your self. The monthly version of Connect offers 25 concurrent attendees in each room, so that would be 24 students and you.
    The meeting does end after it is dormant (no host) for ~15 min, however you can use the End Meeting function (Meeting > End Meeting) to close the meeting and remove everyone, including yourself, from the room.

  • I purchased one photoshop licence, how many computers can install it?

    I purchased one photoshop licence, how many computers can install it? And If you have a limit of computers that can be installed, how can i exceed it? for example, pay addition and ETC. I'm not company, but personal user.

    Two current activations.  If you need more, then you need to pay for a new license.  ISTR a poster in a similar position a month or so back.  I can't remember if he persauded Adobe to change his licens to a Teams Subscription.  What are you hoping to achieve?

  • How many keys can be pressed at once

    i want to play an online rhythm music game.. which would require the pressing of more than one key at one time.. so I wish to know how many keys can be pressed at once without the computer hanging or the keyboard jamming?
    I'm using a Macbook, 2.0ghz, Black with 1 gig ram. Thanks.

    By and large the keyboard does what the programmer of the software tells it to do - part of the programming is to address the input/output devices required by the application. By the same token the programmer can't require you to use keystrokes that can't be addressed through the OS involved.
    It doesn't make much sense for someone to write software that can't be used.
    Regards |:>)
    Bob J.

  • How many files can I combine using PDF Pack?

    Its telling me I can only combine 12 pages?  I need to combine more

    Hi there,
    You can combine up to 12 PDFs at once with Adobe PDF Pack--if you have more to combine, then you can combine in batches of 12, and then combine those combined files. (How many times can I say "combine" in one sentence?)
    Best,
    Sara

  • With the iphone 5, how many people can you text at once?

    how many people can you text at one time, using the iphone5?

    Hi Gabriel38, and a warm welcome to the forums!
    Try less than 100 at a time, (less than 50 for some ISPs).
    You may get your answer here, but It's quite acceptable to start a new topic of your own, feel free to start a new topic to attract more helpers to your particular situation, here's a link if as is often the case, it's hard to find out where to do it...
    http://discussions.apple.com/post!default.jspa?forumID=753

  • How many computers can use final cut once I purchase the license?

    How many computers can use final cut X once I purchase the license through the App store? Will it give me a code I can use to download the serial on a separate computer? Thanks for the answer.

    TYou can use it in as many computers as you own and control. No serial number, just your Apple ID to download. Or just copy it from one machine to the other.

  • How many apps can be open at one time?

    My friend did not know how to close apps. I showed her and was shocked at how many she had open at one time. Everything since she got her ipad over a year ago. She must have had 30 games, pictures, internet, lists, contacts, mail, video, everything was open.
    It made me curious if there is a maximum number that can be open at one time, and if at some point will they automatically close themselves?
    Thanks

    Open apps consume almost no resources, unless they run background refresh. Once they have been inactive for a while, iOS writes the current state back to storage, to free up RAM for other processes. You can see this when some apps, particularly big heavy games like Infinity Blade, relaunch from the starting splash screens instead of taking up precisely where they were left.
    It's still good practice to close down stuff every so often, but not necessary, as you've discovered.

  • How many sockets can be opened to one port

    Hi All,
    There is a service installed on port 4444 of our server. In order to do some work with that service we open sockets to it with socket:localhost:4444. The thing we are finding is that it is quiet expensive to initialise these socket connections per request to our website and I'd like to pool connections. I have implemented a pool but currently this closing the connection when returning to the pool. I would actually like them to stayalive in the pool but I do not know if I can have many sockets open to one port?
    Thanks!

    You are unlikely to get an exact answer.
    The first limit you'll probably run into is the number of file descriptors that can be open at a time. This depends on your OS and configured per-process limits.
    Socket buffers use memory. Amount of memory, allowed process size (if your OS enforces that with in-kernel buffers), and size of send/receive buffers give another limit.
    Other OS-dependent limits, such as a max global file descriptor count, may exist.
    TCP/IPv4 (if you use that) connections are defined by a 4-tuple {source address, source port, destination address, destination port}. As long as source address&port are unique, the same destionation address&port can be used. So theoretically you could have some two hundred trillion connections to a port (32 bit addresses * 16 bit ports minus non-allowed addresses.)
    In practical terms: check max file descriptor count. A few dozen to a few hundred should be ok for web server -class systems. Try and see what works.

  • How many instruments can you open in Main Stage?

    I have got to a point with Main stage where I can no longer open any instruments. Im not going to try to count how many Ive got in there but theres over 100 in about 40 patches. I can open all the ones Ive created, but cant create any more. I'm not sure if this is just a limit in Mainstage or not. It's very frustrating in any case as the handbook seems to say there's no limit to the number you can create.
    By the way what's happened to this site? Where did my old profile go? And all the questions on it? I'm totally confused.

    Hi Joe,
    There is no "upper limit" on the number of tasks that you can have in a plan. Having said that, the complexity of a plan -- including conditions and the use of external tasks -- can certainly be a factor in response times.
    Having said this, 30 seconds seems like a long time and I strongly suggest that you open a case with customer care on this item.
    We have alerted them to be looking for a case from you.

  • How many pages can be open in one single tab before I lose the first page of the tab?

    I use a tab for weather info on many places and I have lost the first few ones if I put too many places. Example: First page is Vancouver, last New York, and in the middle many places. How much pages is it safe to put in a single tab without losing ANY places from the beginning of the tab? EXTREMELY irritating to lose ones as I have to put all the places again (of course in fewer numbers)!
    PS.Mozilla: If I shut down Firefox and I'm in the end of the tab containing the previous weather pages, I only get around 10 or so places backwards and lose all others, this SHOULD CHANGE! I want to have at least 30 places backwards there when I come back! Weather is not the only thing where people want tab-pages to be saved and safely there for the next session. This has bothered me for a year, please change this!

    I'm not totally sure how many pages Firefox can remember. Its a lot though. If you want to view them, and count them if you want, click the back icon and hold it and a list will come up of recent web pages. I like your change idea though.
    Cheers
    Jon

  • How many InputStreams can I open?  seriously

    This came up in a design meeting recently, one of us wants to have this nifty data structure that opens a bunch of FileInputStreams, and the others think it's a bad idea due to possibly OS <-> JVM limitations. So is there a rational limit, and are there any other considerations we're missing? Also, would it be safer to user FIle objects, as from what I understand, the file isn't actually located/accessed on the disk until we open a stream from the file.
    FYI, we're building a library that builds a datastructure to create arbitrary data structures from disk, and then hands them off to a central processing servlet that will manipulate the streams.
    Thanks in advance for the help.

    Operating systems typically have a limit on the number of files that can be open at the same time. This limit depends on the operating system and hardware and can be user or application specific, it's not possible to give a number. But if there are a lot of files and you don't need to read from all of them at the same time it's best not to open them.
    Also, would it be safer to user FIle objects, as from what I
    understand, the file isn't actually located/accessed on the disk
    until we open a stream from the file. If you open a FileInputStream to a file that doesn't exist you'll get a FileNotFoundException, so File objects would definitely be safer.

  • Is there a limit to how many windows can be open on a screen?

    Bored at work again and playing around, is there a limit (real or theoretical) of the numbers of windows that can be open on a Mac at any given time?

    There is an infinite number that can be up at any given time. Just to test it, one fun thing I like to play around with is this:
    Open up a Finder window and hit Command-N, about 100 times. Then push F9 or F8 to see all the windows you opened!
    It's fun to see 10,293 Finder windows open at once. To close them, just hit Command-W the same number of times, or go to Force Quit and Relaunch Finder.
    Have fun!!!
    ~Christoph

Maybe you are looking for

  • Pro's and Cons 2012 vs 2013 Mac Pro

    I can pick up a new (open box) 2013 Mac Pro for a decent price. This is the base machine, 3.7ghz and 12gb ram. I currently have mid-2012 tower model, again the base 3.2ghz and still at 6gb ram. I have upgraded to dual 5770 video cards and a 256gb SSD

  • Is there a problem with itunes (11.1 latest version) on a windows 7 non-administrator (standard) account?

    When I tried to update my dad's iphone 5 to iOS 7 on a windows 7 standard account an unknown error was encountered and he lost everything! It also doesn't recognise my mum's iphone 4s (already updated to iOS 7), it gets an error, but her phone works

  • Syncing ipad 2 calendar with yahoo calendar

    When I go into my ipad calendar my yahoo calendar is atomatically listed, and it shows items from my yahoo calendar from the past year.  but as I add to my yahoo calendar it is not updating to my ipad 2. I'd like it to sync everytime I open the calen

  • In PL26 its not printing

    Hi Experts, We are facing the issue regarding printing which is not printing 5 at a time. Print Setup had assigned in: PLD-> Document Properties-> Number of copies 5. In PL26 only its not printing .. Can any one give the solution regarding this issue

  • MS Active Directory and SAP NetWeaver ID Mgmt..

    Hi Experts, We have NW IDM 7.1 installed on HP UX with Oracle 10.2 . I was wondering if; 1.This architecure will workwith AD 2000 for User / group creation on AD. ( I am refering to slide 97 in ManagementIDM Connector Overview document) 2. Our AD iwi