Hi Experts,
When execute LX16 for PI, is this process updates last inventory date at bin level or quant level table ?
After completing LX16 process, and continue to execute Cycle count in LICC , the same materials in which physical inventory were completed using LX16 are praposing for inventory?
Question : why is this even thou PI is completed in LX16, and again same materials were praposed for physical inventory in LICC ?
Is this a SAP standard behaviour?
How Can i avoid for not letting the LICC process to consider materials  in which PI completed with LX16.
Edited by: Loki TV on Nov 9, 2010 11:28 AM
Edited by: Loki TV on Nov 9, 2010 11:30 AM

There is a customizing to define the default values for MI31 selection. But you only need to customize it if you want certain fields in MI31 differently proposed.
Just check in MI31 selection what is behind the button ACC to STOCK in the middle of the screen.
If the boxes for include already counted material / include already counted batches are empty, then it will not include counted materials into the next physical count.
Regards,

Similar Messages

  • Is it possible to enter more than 333 items in a physical inventory Doc.?

    Hi Gurus
    I want to enter more than 10000 line items in a physical inventory document. how can I achieve this please help. We are using SAP IS Retail.
    Regards
    Muneer . V.K

    Hi
    We are using PDA device to enter counted qty before that we will arrange all articles based on MC and we will distribute the work to different counting teams. We have a Z program developed for PDA with following logic.
    Pseudo Logic     
    1)     Application is used to create Physical Inventory Count.
    2)     There are 2 options provided for physical Inventory Count
          i)  With Reference of Physical Inventory document
          ii) Without Reference.
    3)     If with reference is chosen , Inventory document no. is available for input
    4)     If stock type is entered in without reference then vendor is mandatory for input.
    5)     User can enter the site, storage location and the following validations will be done on these screen inputs
    u2022     Validate the site against SAP entry and check whether the ser has authorization in the site
    u2022     Validate the storage location
    u2022     Validate Vendor if entered
    u2022     Validate Physical Inventory doc no. if entered
    6)     In second screen, user will scan EAN/UPC number of the article and the following validations will be done.
    u2022     Validate the EAN/UPC number. Check whether the number is available in SAP
    u2022     Check whether the article is extended for the site
    u2022     Get the base unit of measurement for the article
    u2022     Get the article description from the table
    u2022     Get the conversion factors for the barcode unit of measurement
    u2022     Get Stock on hand for the article
    7)     Perform the following validations on the unit of measurement input
    u2022     Check whether the unit of measurement is available in the system
    u2022     Check whether the unit of measurement is defined for the article
    8)     Perform the following validations on the quantity entered by the user
    u2022     Check the format of the quantity input
    9)     Move all the details along with quantity to a buffer table. Clear all the input fields for the next set of scan and move the current details to the last scanned variable for display
    10)     In case duplicate scanning of article, cumulate quantities instead of adding new entry to the buffer table
    11)     If the user click on option DISP, call the third screen
    12)     In third screen, all the EAN/UPC numbers will be displayed with an option for scrolling and removal
    13)     When the user choose option SAVE from the third screen, create physical Inventory document and update the count by following the below steps
    u2022     Prepare the header parameters for the BAPI
    u2022     Prepare the line Item parameters for the BAPI
    u2022     Create PI document using the BAPI_MATPHYSINV_CREATE_MULT and BAPI_MATPHYSINV_COUNT
    u2022     Trigger error message in case of any failure
    14)     Clear and refresh all the variables and internal tables to proceed
    15)     Create HTML templates for the screen in SE80 under the internet service ZNESTO
    16)     Publish the IAC templates for the screens in SE80 under the internet service ZNESTO
    Regards
    Muneer V.K

  • View Table to update Physical Inventory Number Range.

    Hi,
    I am looking for the 'View Table' Name to update Physical Inventory Number Range in OMMB transaction.
    I will have to do it using SM30 as OMMB is display only.
    Thanks

    Hi,
    OMBT still cant help me because I dont have write access on this client.
    Are you aware on how to get the View Table to Maintain Number Ranges for Physical Inventory?
    Thanks,
    Rohit.

  • Problem in MARC Table - when count A, B, C Physical Inventory Indicator

    Hi,
    We have 75000 material in MARC table of 1 Plant.
    But when we saw materials with Physical Inventory CC indicator- ABCIN (A + B + C), there are approx. 63000 material's.
    How it's possible??? what is the diff. of 12000 material's...
    Note: - There is no D indicator material's in MARC.
    Plz help..
    Regards..

    No, there is no problem. It can be done if you are sure that all entries should contain value D instead of space. But before doing this, you should probably analyse and find out a reason why it happened. Maybe there were an error in migration program (if the materials were migrated). Or probably there is some user-exit implemented for maintaining material master and it contains error. Which plant is for such materials in MARC table if there is no plant view maintained? Should these entries be in MARC table? I do not know. I am not MM consultant, just an ABAP developer. But from technical point of view, there is no risk in such update, there is a risk only from business point of view and I am not the one to judge this risk.
    Adrian

  • Updation of Physical Inventory Blocking Indicator

    Dear All,
    I would like to know how the Physical Inventory Blocking Indicator is updated in the material master recored storage location stock Tab....
    Is there any setting in customizing for this as its not getting updated when I create a Physical Inventory document... ?

    the indiactor is not getting updated at all, If I do it manually by table maintainance the posting block works fine....
    but need a programme name thru which this field is updated. Can anyone tell me where  which programme MARD-SPERR field is being used.
    I dont have access to any standard system where this indicator is updated automatically
    Thanks in advance---

  • Table and field name for Physical Inventory

    Hi Experts,
    As i have to put radio buttons with 2 blocks in a report for Phys. Inventory. Please tel me the following fields:-
    Block1.   Table name and field ( flag field) that shows physical inventory completed & not completed. (so many indicator fields but i want exaact one) or any other way to no PI done or not.
    Block 2.  Table name and Field( flag field ) for Physical Inv. Still to be executed , Physical Inv. Still to be Closed, Phy Inv. Executed, Phy Inv. Active Again.
    Regards
    Nikhil

    <b>go to se80
    click on repository information system  
    expand ABAP Dictionary
    expand fields
    double click on table fields</b>
    on the right side of the screen type the description of the field you want to know and execute to know the field name and the table where it is used.
    <i>follow the above steps to search by yourself rather than posting each time</i>
    regards,
    srinivas
    <b>*reward for useful answers*</b>

  • Lx16  physica inventory

    hi kishore,
    how are you,
    here one issue is relating to physical inventory here they asking while runing the lx16 the report is not coming
    issue is
    AU15-NHILL Missing Bins in report
    We have run the continuous counting process LX16 for:
    Warehouse No: AC1
    Storage type: S01
    Storage Bin:  A1 to I6
    The report did not give me bins B1 and I1 to I6 - why
    there is stock sitting in B1, I2 and I3
    See report in LI04n for listing
    i think if once the counting is happened it will not show ,how can we see the counting is already take place are not yet take is there any t.code or what is the process and suggest me how to solve this issue
    thanks inadvance.

    remove the two flags (only...)in the lower part of your LX16 selection screen .

  • Physical inventory tables

    Hi,
    Can anyone let me know what is the table for physical inventory which are carried out for warehouse.
    I want to know the table in which my before count  and after count results gets posted.
    Sunil

    Hi
    Check the table ISEG and element ERFMG and MENGE for counted quantity and book quantity.
    Thanks

  • Physical Inventory Count Document TABLE

    Hi ,
    Can anyone please tell me the TABLE for physical Inventory Count .
    In which TABLE , all the datas such as physical document number etc will be saved .
    Regards,

    Hello Sandeep,
    You will find count entry in
    - ISEG if using IM.
    - LINV if using WM.
    Thanks & regards,
    Arif Mansuri
    Reward the point if answer is useful.

  • Physical inventory document was missing in the table

    Dear all,
    My client have done a physical inventory means they have counted and post the difference also.
    but i was trying to see the document not showing in the table or mi20 or any other transaction.
    after that lot of documents has been created, only particular phy. inventory document was missing.
    Please help me resolve this issue.

    how do you know that the count was posted if the document is not in the tables?
    A document is deleted physically if the document has no counts posted and you delete it in MI02.
    The only other legal option to get a document off the tables is with archiving.
    In transaction SARA for object MM_INVBEL click the button for Adminstration to see if there was an archiving done.

  • Maintain Table T158I-Transaction Control: Physical Inventory

    Dear Expert,
    How to maintain table T158I - Transaction Control: Physical Inventory in Customizing?
    Thanks for your help!
    ICBUMA

    This is a SAP internal control table for physical inventory and not designed as customizing  activity for customers.

  • Physical Inventory in WM

    Hi,
    I got some questions related to physical inventory.
    Our customer wants a physical inventory based on the material (both for IM and WM). In WM "next empty bin" for putaway and "FIFO" for picking are used.
    During the physical inventory process the following should be possible:
    1) Per day a certain amount of materials should be inventoried (depending on the time the warehouse worker has time for that). That means in case of WM it should be possible to enter the quantity of materials to be inventoried and the inventory document then contains all the bins where the material is.
    2) A report that shows which materials are already inventoried and which are not inventoried so far.
    The only possible physical inventory method in SAP for 1) could be cycle counting as this provides the information in MARC when the last inventory was done. For all other methods (annual, continous) this information is stored in the bin only. But I could not find anything to enter the amount of materials I want to inventory. If I use cycle counting I would get all materials the first time running LX26. Sure I can select 50 bins per document and only activate some of the documents but then it could happen that the same material is in more than one document.
    2) No standard report available.
    Is there a way to do that in standard SAP? In case it involves changes where do you see them?
    Cheers
    Mathias

    Hello Mathias,
    <b>1) Per day a certain amount of materials should be inventoried (depending on the time the warehouse worker has time for that). That means in case of WM it should be possible to enter the quantity of materials to be inventoried and the inventory document then contains all the bins where the material is.</b>
    I suggest you to use Quant based cycle count inventory (Transaction code LICC), with this transaction you will be able to give your material input and you can also select the quant for which you want to carry out the inventory, it will not block entire bin
    For more informaiton <a href="http://help.sap.com/saphelp_erp2005vp/helpdata/en/7b/bb0bc8b3c911d3b2ad0050045571f7/frameset.htm">Cycle count for Quant</a>
    2) A report that shows which materials are already inventoried and which are not inventoried so far.
    If you are using the inventory other than cycle count in that case, it will update the inventory details at bin level, but if you use Quant Cycle count inventory it will update Quant data as well so you can generate report from LQUA table or use the standard report LI15 transaction code
    <b>The only possible physical inventory method in SAP for 1) could be cycle counting as this provides the information in MARC when the last inventory was done. For all other methods (annual, continous) this information is stored in the bin only. But I could not find anything to enter the amount of materials I want to inventory. If I use cycle counting I would get all materials the first time running LX26. Sure I can select 50 bins per document and only activate some of the documents but then it could happen that the same material is in more than one document.</b>
    to resolve this use LICC instead of LX26
    2) No standard report available.
    There are couple of reports available which are more business user friendly with detailed invormations.
    Go to SAP Menu --> Logistics --> Logistics Execution -> Information system --> Warehouse --> Phy Inv --> with bin inventory
    Hope this helps.
    Regards
    Arif Mansuri

  • Handling Unit Status (0031) - Physical Inventory

    Hello Friends,
      We need to know when the system change HU status to 0031 in table VEKP (HU Header) .  We assumed that, it will be during physical inventory posting for HU's and for testing the following transactions are executed -
    1. HUINV01 -
    2. HUINV03
    3. HUINV04
    4. HUINV05
    However after physical inventory doc posted and material document generated for difference, system still showing the HU Status as 0020.
    In this regard, please suggest whether we are doing the correct way or what is the method to adjust the HU's and when the system update the status 0031 in HU table.
    Appreciate your supprt.
    Thanks
    Best Regards,
    Goutham

    Hello Friends,
      Very greatful for your support.
    Best Regards,
    Goutham

  • Physical inventory - Last inventory date

    Hi,
    We carry out physical inventory using LICC.  Two parts were counted on previous day, however when a new list was generated to count parts  two parts that were counted previously also appeared in this list.
      'Old inventory date' field on table LAGP for these two parts did not get updated either. 
    Please can anyone let me know whey this could be happening ?
    Thanks
    Mira

    I thought the same thing when i checked quant values in LINV and LAGP. 
    1.  I did find more than one quant for the same material.
    2.  User did not give any values in LICC except range of material (to include all the parts in given warehouse and storage type), warehouse number and storage typ.
    Should not this take into account whatever quants there are in the system ?
    I am not IM expert and appreciate your quick reply.
    Thanks
    Mira

  • Problems with Batch Number in WM Physical Inventory

    I am trying to troubleshoot a client that has the following scenario:
    1. Material in storage bin doesn't have batch number
    2. Batch management has been activated.
    3. A physical inventory document was created for the location where the material is.
    4. The physical inventory has been counted.
    5 When trying to write off differences in LI20 it is giving an error to enter a batch number.
    I understand clearly that the system is interpreting that the batch number is required and missing in master data. I am not able to modify batch number for the quant in LS22.
    The implications behind deactivating batch number right now would be too complicated and not the right procedure either.
    What is the correct procedure in this case?
    Thanks!

    Hi José, I do not think your point 2 can be right. If a user tries to switch on batch management when there is stock or any open transactional data (POs, Sales orders etc) the SAP throws an error. The only way to activate BM with stock in hand is, as Jurgen has pointed out, through a report or a direct table update that causes inconsistencies.
    That said, please have a look at the below document. It details the report provided by SAP to deactivate/activate BM with stock. Please use them with the utmost caution, carefully reading all the disclaimers given by the author, before performing these steps to avoid further inconsistencies.
    http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/b009b1e5-f3df-2b10-7289-ff87d139dce1?QuickLink=index&…