Plant Connectivity

Hi,
Is there some detailled information available for Plant Connectivity? (both functional and technical)
I have found this so far, but it does not give enough information:
http://help.sap.com/saphelp_pco20/helpdata/EN/46/a00344d44852b7e10000000a155369/frameset.htm
kind regards,
Michel

Here are some additional notes:
The u201CSAP ME PCo Extensionsu201D have now been made available to customers and partners via SAP Developer Network (SDN). Included with the extensions are an implementation guide and example scripts. The package delivers a file monitor agent and an ME destination to support the integration of factory floor equipment to SAP ME for discrete manufacturing industries. The package provides a light-weight, configurable, transformation and transaction engine and scripting capability, in the ME Destination, to support conditional processing. The delivered examples illustrate the parsing of a machine generated data file and the communication of some of this data to SAP ME via web services.
PCo and the SAP ME PCo Extensions enable SAP ME to:
u2022 Ensure that the correct components are going to be installed
u2022 Track the Work in Process
u2022 Collect traceability information from equipment
u2022 Stop equipment to prevent the creation of bad product
u2022 Log a nonconformance when a problem occurs at equipment
u2022 Supply equipment with needed information, such as component material data
Find out more:
u2022 Download the extensions, implementation guide and example scripts via the SDN SAP Software download Catalog Link: http://www.sdn.sap.com/irj/scn/downloads?rid=/library/uuid/e04e4288-1208-2d10-48a7-e63029f1fe18

Similar Messages

  • Plant Connectivity - RFC Destination

    Hi,
    I configured Plant Connectivity 2.0 (V2.0.0.33) according to the following document:
    SAP Plant Connectivity 2.0 - Configuration Guide for EWM
    On the EWM side one have to create a TCP/IP connection. There is a brief instruction in the EWM help:
    Setting Up the Material Flow System > System Settings > 7.
    The RFC Client connection test succeeds. The Connection Test in the SCM/EWM system results in error.
    There are some ambiguous points in the configuration for me.
    PCo Management Console > Destination Systems > RFC Settings > Server Settings
    - Program ID
    Should the Program ID be the same as the  name of the TCP/IP Connection?
    - Gateway Service ?
    Here I took the sapgwxx which is listed in the error message.
    - Application Server ?
    What is meant by Application Server? It is the server where Plant Connectivity is installed? Or is it the SAP server?
    SCM > SM59
    The instruction in the MFS System Settings number 7 about the RFC destination doesnt specifies which settings to make here. Also the EWM-MFS-PCo guide doesnt give any detail about that. There is only a hint on page 15 that one can test the connection.
    I would appreciate any help! Thanks in advance!
    Kind Regards,
    Bahit A.
    Edited by: bahitaktas on Jun 8, 2010 2:04 PM

    I solved the problem!
    TCP/IP Settings:
    - Activation Type -> Registered Server Program
    - Registered Server Program > Program ID -> Program ID from PCo
    PCo Settings:
    PCo Management Console > Destination Systems > RFC Settings > Server Settings
    - Gateway Service ? Gateway listed in the error details if the TCP/IP connection in sm59 fails
    - Application Server ? Analogous the host listed in the error details ...
    http://help.sap.com/saphelp_nw70/helpdata/EN/22/042652488911d189490000e829fbbd/frameset.htm
    Edited by: bahitaktas on Jun 8, 2010 2:53 PM

  • Plant Connectivity Error failed to create ConnectivityAgentProxy

    Dear experts,
    I currently installed installed PCo on a XP Machine and after I change the network ID of the PC and the workgroup the agent instance is not able to start properly. I receive the following message:
    10.10.2011 22:28:32,.,6,1016,TEST_OPC,Error,Host,failed to create ConnectivityAgentProxy,"The server process could not be started because the configured identity is incorrect.  Check the username and password.
    Server stack trace:
       at System.ServiceModel.Channels.ServiceChannel.HandleReply(ProxyOperationRuntime operation, ProxyRpc& rpc)
       at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs, TimeSpan timeout)
       at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs)
       at System.ServiceModel.Channels.ServiceChannelProxy.InvokeService(IMethodCallMessage methodCall, ProxyOperationRuntime operation)
       at System.ServiceModel.Channels.ServiceChannelProxy.Invoke(IMessage message)
    Exception rethrown at [0]:
       at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
       at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
       at SAP.Manufacturing.Connectivity.IPCoAgentControl.Start()
       at SAP.Manufacturing.Connectivity.ConnectivityAgentProxy.Start()
       at SAP.Manufacturing.Connectivity.WcfHost.Start()"
    10.10.2011 22:28:32,.,8,1016,TEST_OPC,Error,ServiceFaultManager,Manufacturing Fault: REASON = The server process could not be started because the configured identity is incorrect.  Check the username and password.
    As the other applications like OPC Scout are able to connect to the DCOM (at least this is my understanding) in order to query the OCP Server, it seems to me that there is a Plant Connectivity problem. I tried to find out where the settings ConnectivityAgentProxy are detailed - I thought something like an .ini, .xml file - but unfortunately I did not find anything. Do you have any suggestion, advice?
    Thanks in advance,
    Florin
    Before I start with installing image of the PC with the image before doing the network id name change i would like to ask you if there is any setting, configuration file

    Do you have a named user entered for the Agent Instance Service User name/password?  If so, you may have to delete and re-enter the name\password to reset this.  If you are using DCOM over a workgroup, the same workgroup user name/password must be set up on both the PCo server and the OPC Server PC's.
    Hope this helps.
    - Steve

  • SAP Plant Connectivity Error

    Hi All,
    We are using Plant Connectivity 2.0.1.7 with SAP MII 12.1.4.
    we have configured two agents which are running automatically but agents got stopped whenever there is upgrade in MII and again we need to reconfigure agents.
    Please resolve this issue.
    Regards,
    Manoj Bilthare

    Hi, just to follow up on what Manoj has mentioned.  MII was always on 12.1, but patches were updated.  When this happened, we got errors that the PCo couldn't connect to the Destination (MII).  What happened, was the PCo Agent would start and work for a period, but then when it tried to re-connect (I think after the initial session timed out), it wasn't able to, saying invalid version of MII.  If we stopped and started the PCo, it would run for a time and then fall over again.
    We reconfigured the MII Destination (still just selected 12.1) and then deleted the PCo agents and re-configured them.  Now we're getting the error that there's an invalid date format - not too sure where it could pick that up other than from the OPC Server.  All the Agents are doing is monitoring one tag each.  If the tag value = 1, then the notification fires and calls the MII transaction.
    The OPC Source hasn't changed, all that's changed is we've patched MII.
    Has anyone else experienced this same sort of behaviour from the PCo 2.0?
    Edited by: Lawrence Prinsloo on Mar 15, 2010 4:44 PM
    Edited by: Lawrence Prinsloo on Mar 15, 2010 4:45 PM

  • Plant Connectivity Active Monitor Service

    Hi,
    I was wondering if somebody could tell me exactly what the Plant Connectivity's ActiveMonitor service is used for.  I tried to google and search the forums for ActiveMonitor and have not found anything useful.  I have also done some testing with enabling and disabling the service, and have yet to figure out exactly how it is utilized.
    Any help would be appreciated.
    Thanks,
    Justin

    I solved the problem!
    TCP/IP Settings:
    - Activation Type -> Registered Server Program
    - Registered Server Program > Program ID -> Program ID from PCo
    PCo Settings:
    PCo Management Console > Destination Systems > RFC Settings > Server Settings
    - Gateway Service ? Gateway listed in the error details if the TCP/IP connection in sm59 fails
    - Application Server ? Analogous the host listed in the error details ...
    http://help.sap.com/saphelp_nw70/helpdata/EN/22/042652488911d189490000e829fbbd/frameset.htm
    Edited by: bahitaktas on Jun 8, 2010 2:53 PM

  • SAP Plant Connectivity SDK 2.1 for download

    u2009Hello. Excellent info.
    Please, we cant find SAP  Plant Connectivity SDK 2.1 for download. The note 1399331 - Plant Connectivity 2.1, says that we can download from:
    https://service.sap.com/swdc ->Downloads -> SAP Installations & Upgrades -> Entry by Application Group -> Composite Application -> SAP Manufacturing Integration and Intelligence -> Plant Connectivity SDK -> Plant Connectivity SDK 2.1 but this path is not correct.
    Please, can you help us?
    Thanks.
    Gustavo Barboza
    PROPILCO

    Gustavo,
    Yes it seems that the note is wrong. I will contact the author and let them know. To find it go to .../sdwc > Search All Categories > copy and paste "Plant Connectivity SDK 2.1" in the field > click the link for Installation product > click the download tab.
    That should do the trick
    Regards,
    Kevin

  • Using Plant Connectivity

    Hi,
    Is there a blog or document explains detailly using of Plant Connectivity?
    Thanks.

    Cemil - I see you now have dual identities on SDN with 2 different logins?
    If your company or customer was part of the ramp-up process for PCo 2.0 you would have access to the ramp-up knowledge transfer materails on service marketplace (http://service.sap.com/rkt).  The learning map for PCo contains numerous learning objects that used in conjunction with the help would probably address your question.
    Perhaps phrasing your inquiry as to what it is you are trying to accomplish would give the community better insight on how to help.
    Think of PCo 2.0 as a trigger agent that sends an xml message to a business logic transaction that starts a workflow, business process, or in essence just 'does something' based upon the PCo trigger condition being met.  From an integration standpoint it's a matter of creating the necessary transaction in MII and defining the InputXML property to receive the message from the PCO agent trigger.

  • MII and Plant Connectivity 2.2 Bi-directional Socket Connection

    Hi,
    I have to send a command to a serial device from within MII via a socket connection to be able to have a respons from the device.  I know in Plant Connectivity a socket connector can be setup. But is it also possible to send a message from MII to the serial device over Plant Connectivity, because it seems that the socket can only be setup to trigger notifications based on received messages from sources (and not from destinations). I read this functionality was planned to be build into Plant Connectivity 2.2, but I can't figure out how to set it up?
    kind regards,

    Hi Bram,
    We can set up connection between PCO & MII through "UDC" connector. UDC connector is available in MII through
    Data Services --> Data Servers --> New --> UDC and click on "OK" button.
    You need to provide all PCO system details like server name, Port number etc and save the connection. Check the status of connectivity through Data Services --> Connection Status.
    Go through the URL : http://help.sap.com/saphelp_mii121/helpdata/en/43/e80b59ad40719ae10000000a1553f6/frameset.htm
    Navigate to Data Services --> SAP MII Workbench --> Query Template --> Tag Query
    Upon successful connection, open SAP MII workbench (Data Services --> SAP MII Workbench) and create a new "Tag Query" template to pull details from PCO.
    So far, we pulled information from PCO, manipulated those values in MII and send these values to ERP to create notification. Let us know business scenario on which you need to send back information to PCO from MII.
    Thanks
    Rajesh.S

  • SAP Plant Connectivity  2.1.0.55 on Windows 7 Enterprise 32bit problem

    I tried to install SAP PCO version .1.0.55 on Windows 7 Enterprise/32bit, whenever i try to start
    the agent, i get the following error in the Log:
    =================================================
    Server stack trace:
       bei System.ServiceModel.Channels.ServiceChannel.HandleReply(ProxyOperationRuntime operation, ProxyRpc& rpc)
       bei System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs, TimeSpan timeout)
       bei System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs)
       bei System.ServiceModel.Channels.ServiceChannelProxy.InvokeService(IMethodCallMessage methodCall, ProxyOperationRuntime operation)
       bei System.ServiceModel.Channels.ServiceChannelProxy.Invoke(IMessage message)
    Exception rethrown at [0]:
       bei System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
       bei System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
       bei SAP.Manufacturing.Connectivity.IPCoAgentControl.Start()
       bei SAP.Manufacturing.Connectivity.ConnectivityAgentProxy.Start()
       bei SAP.Manufacturing.Connectivity.WcfHost.Start()"
    02.11.2011 13:04:37,.,9,3684,ya,Error,ServiceFaultManager,Generating Manufacturing Fault: REASON = General PCo Fault: [severity = Fatal] COM Exception
    [Unable to decode an error code.]
    02.11.2011 13:04:37,.,9,3684,ya,Error,OpcDaAgent,COM Exception [HRESULT = -2147024809] from LegacyOpcWrapper,"Unable to decode an error code.
       bei SAP.Manufacturing.Connectivity.Agents.Opc.DaServer.DecodeResult(Int32 errorCode)
       bei SAP.Manufacturing.Connectivity.Agents.Opc.OpcServer.CheckResult(Int32 hr)
       bei SAP.Manufacturing.Connectivity.Agents.Opc.DaServer.CreateGroup(String name, ValueType updateRate, ValueType timeBias, Single deadband, Boolean requiresAdvise)
       bei SAP.Manufacturing.Connectivity.Agents.Opc.Da.OpcDaAgent.CreateTagQueryGroup()
       bei SAP.Manufacturing.Connectivity.Agents.Opc.Da.OpcDaAgent.EstablishConnection()"
    02.11.2011 13:04:04,.,1,2868,ya,Error,Host,failed to create ConnectivityAgentProxy,"General PCo Fault: [severity = Fatal] COM Exception
    =======================================
    Did anybody has the same Problem? Is this somehow cause by a .Net problem? (i do have 4 Client and 4 Extended installed)
    Thank you very much in advance for helping me
    best regards,
    Thomas L.
    Edited by: Thomas Lustig on Nov 3, 2011 12:48 PM
    Edited by: Thomas Lustig on Nov 3, 2011 2:03 PM

    Thomas,
    Did you ever get an answer to this? I am facing the exact same problem.
    Many Thanks,
    Colm

  • Error on Add Destination in Plant Connectivity Notification Management

    Hello Experts,
    I am creating a Notification in PCI > Notification Management.
    In Notification Details details screen, in the Destinations tab when i click on 'Add Destination' i get a poup with following message.
      Error while fetching Destinations
      Cannot read property '0' of null
    PCoConenctor Data server is created and is running.
    When i do the same in PCo, it works.
    Version:
    MII: 15.0 SP03
    PCo: 15.0 SP03
    Am i missing any configuration?
    Any help would be highly appreciated.
    Regards,
    Shridhar.

    Hi Sindhu,
    Thanks, I created a Simulation Destination and now i see values in 'Add Destination'.
    Now, upon saving, when we click on Activate or Publish button, i get the following message.
    ERROR
    Cannot Publish:Mandatory fields not entered
    Trigger type is 'Always'; Expression is default
    Nothing set in Output
    In Message delivery, values are default.
    Am i missing anything.
    Thanks in advance.
    Regards,
    Shridhar..

  • Plant Connectivity: failed to create ConnectivityAgentProxy

    Hello
    I have a problem with PCo.
    After running insatnce of agent I have an error in log:
    Date Time, Machine, Thread ID, Process ID, Process Name, Event Type, Source, Message, Stack Trace
    07.06.2011 17:25:23,.,6,7728,agent,Error,Host,failed to create ConnectivityAgentProxy,"General PCo Fault: Invalid server information.
    Parameter name: input
    [Invalid server information.
    Parameter name: input]
    07.06.2011 17:25:23,.,8,7728,agent,Error,ServiceFaultManager,Generating Manufacturing Fault: REASON = General PCo Fault: Invalid server information.     
    Parameter name: input     
    [Invalid server information.     
    Parameter name: input]      SEVERITY = Fatal,""
    What is it? What's problem?

    Dear Dimitry,
    I have a similar problem - I think I cause it because I change the name of the PC (Network ID) - I was wondering if you were able to repair the russian version or you just installed the pco on another pc? If you repaired the windows version what have you done?
    Thanks  a lot for your time!
    Florin

  • Creating a central DC for plants that have mutliple company codes

    Hi,
    We are looking to consolidate all of our distribution from 5 manufacturing plants (which all have different company codes) to one central distribution center in a single company code.   Has anyone had any experience with this scenario?  We will need to turn on warehouse management at the central DC and have been told that any plants connected to a warehouse in WM, have to be all in the same company code.

    Karen,
    We are looking to consolidate all of our distribution from 5 manufacturing plants (which all have different company codes) to one central distribution center in a single company code. Has anyone had any experience with this scenario?
    Yes
    We will need to turn on warehouse management at the central DC
    Presumably this is for reasons other than the consolidation.  Using or not using WM will have no impact on company codes.  From what little I know about your business model change, there is no reason for you to use WM (other than the additional functionality, which will intrinsically improve warehouse efficiency).
    and have been told that any plants connected to a warehouse in WM, have to be all in the same company code.
    This is not a SAP limitation!  There may, however, be business reasons why you need to do this.
    A Distribution Center is not the same as a Warehouse in SAP.  A DC is a special kind of plant.  Plants are assigned to company codes, and the ownership of the goods in this plant are generally held by that one company code.
    As Jurgen mentioned, a SAP Warehouse can encompass many plants, with many storage locations, each of which may belong to several company codes.  WM doesn't care. 
    Storage locations are members (subsets) of plants.  A given storage location will always be connected to a single plant, and the inventory of all storage locations in a given plant will be owned by the company that owns the plant.
    From your short list of requirements, I believe that your logistics model should be to ship the product from your originating plant(s) to the DC (plant).  The traditional way to do this is via Stock Transport orders.  STOs can be intercompany or intracompany, required financial documents and postings can be configured to meet your company's needs.  Other methods are also possible.
    You mentioned that your DC would be one company code.  Therefore, the sales orders will be placed against one plant (the DC).  Delivery splitting would not be an issue.
    Now, I notice in subsequent responses you seem to be thinking that you will ship from multiple company codes (plants).  This is contrary to your original requirement list.   As asked by Jurgen, where do you wish to consolidate your stock and where do you wish to consolidate your shipments?
    Best Regards,
    DB49

  • Can we run xMII without Plan Connectivity?

    Gurus:
    We are previewing the install guide for xMII and Plan Connectivity.
    I do not see the dependency between the two components.
    Do we have to install Plan connectivity if we run xMII?
    Thanks!

    Plant Connectivity (PCo) and the Universal Data Servers (UDS) are optional supporting components of MII, for certain types of data connectivity and specialized alerting, but are only required when necessary.
    http://help.sap.com/saphelp_pco21/helpdata/en/46/a00344d44852b7e10000000a155369/frameset.htm
    Take a look at the Source Systems mentioned here for example of data type use cases.
    http://help.sap.com/saphelp_xmiiuds40/helpdata/en/index.htm
    Here you can see the types of connections available.

  • Scheduling agreement from a plant of different co. code

    is it possible to create a scheduling agreement to procure items for a plant connected to co.code 1 from a plant connected to co.code 2 ? if yes , how ?

    Hi,
    Since sheduling aggrement is at Plant level, I dont think so we can create a Schduling aggrement for plant connected to ccode1 and other plant connected to  ccode 2.
    Also it shall have other financial impact
    Rrds,
    Shiva

  • Seimens HMI Integration with SAP MII

    Dear MII Experts,
    We are trying to integrate shop floor systems with SAP MII for discrete manufacturing industry.
    I came across the client has 70+ machines in the plant .the vendor is "DMG"
    Seimens HMI is installed on each machine .
    What are the possible ways here to connect to PLC from MII
    I am very new to this integration part .
    Can MII directly connect to Seimens HMI .
    I am very new to this area , client is ready to pay extra cost for any extra interfaces .
    Please suggest me the architecture to follow .
    Please give me a detailed explanation here , please correct me if I my explanation is wrong here
    Please reply me for any other clarification

    Hi Eswaraiah,
       To access the PLC data in MII, you would need couple of things more.
    1. OPC Server where the PLC stores the data.
    2. PCo (SAP Plant Connectivity) that can read the data from OPC Server and send the data to MII for manipulation.
    From PCo MII can read the data and you can then perform your business logic. Also, PCo has built-in notification settings which can trigger MII's transactions based upon some conditions.
    So I believe, your landscape would look like
    Siemens HMI --> OPC Server  -> PCo --> MII
    Check these out...
    PLC Integration with SAP MII
    Connecting MII to PLC devices
    Communicating with PLC
    Regards
    Tufale Ashai