Possible Version Conflicts

I am currently looking at SQL Server 2014 trial version and thinking about getting the developer edition. I have a potential client that has 2008 R2. My guess is that I will need to develop in 2008 R2 to avoid any version issues. If so, can 2008 Express
reside along side of 2014?
Alton Brisbane, Jr.

Hello,
Yes. You can have SQL Server 2008 or SQL Server 2008 R2 side-by-side with SQL Server 2014 without any issues.
Of the last 5 SQL Server versions, The only versions you may have issues when installing side-by-side is SQL Server 2008 and SQL Server 2008 R2.
https://msdn.microsoft.com/en-us/library/ee210714(v=sql.105).aspx
Hope this helps.
Regards,
Alberto Morillo
SQLCoffee.com

Similar Messages

  • Possible version conflict, sending purchase order to SUS in MM-SUS scenario

    We are currently trying to get the MM-SUS scenario working. In this
    scenario, we create a purchase order in the ERP/MM system. The
    purchase order is then transferred into SUS via XI/PI.
    After creating a purchase order in the MM system, the purchase order
    reaches the SUS system, but then errors-out in the SUS system upon
    posting. The specific error is paraphrased as follows:
    No interface action for sender or receiver found (from Trace)
    PARSE_APPLICATION_DATA
    CX_ST_MATCH_ELEMENT
    System expected the element http://sap.com/xi/SAPGlobal20/Global;
    PurchaseOrderRequest
    We suspect a version conflict. The SUS version is 7.01. The XI/PI
    system is version 7.11.
    Can you confirm or rule-out a version conflict?
    The Integration Builder scenario we are using is Plan
    Driven Procurement with Supplier Enablement.
    We have tryed many variations in Integration Builder, but all
    produce errors in SUS.  The test tool in Integration Builder also shows errors
    for certain message types.  The message type ORDERS.ORDERS02
    needed to be added manually, and did not come along with the scenario.
    Edited by: Bill Guderian on Mar 19, 2010 4:53 PM

    Any clue from here.
    Note 936003 - ERS Invoice causes conversion error within SRM
    When the SRM system attempts to process an ERS Invoice sent from the MM backend, a PARSE_APPLICATION_DATA CX_ST_DESERIALIZATION_ERROR fault is thrown.
    Other terms
    CX_ST_DESERIALIZATION_ERROR PARSE_APPLICATION_DATA SUS SRM EBP ERS Invoice XI Exchange Infrastructure Mapping
    Reason and Prerequisites
    This error will occur when the IDOC does not have a VPREI value; it is the result of an error within the divide logic of the XI mapping operation.  This operation is performed within the XI system.  A calculation of NETWR/MENGE is performed; however, the result is not properly formatted.  As such, 72.30/10 produces a result of 7.2300002. This value is too long for the inbound SRM proxy and hence the error is thrown.
    Solution
    The solution to this problem is to add a FORMATNUM function within the XI mapping operation.  This restricts the result to 2 decimal places, which adheres to the definition of the inbound proxy.
    Step by step directions on how one implements the FORMATNUM function are as follows:
    1. Log into the XI system with SAPGUI
    2. Start the Integration Builder:Design tool (for steps on how to do this, review the steps below):
        a. Run transaction sxmb_ifr
        b. This will cause a browser to come up.  Select the Integration Repository link
    3. In the left pane, select the Objects tab
    4. Navigate to the SAP SRM SERVER ' SAP SRM SERVER 5.0 ' http://sap.com/xi/SRM/SupplierEnablement/Global --> Mapping Objects --> Message Mappings folder
    5. Double-click on MM2SUSInvoice
    6. The right pane will display the mapping object
    7. Select Edit mode
    8. In the box that contains the output (Message Type: InvoiceRequest), navigate to InvoiceRequest ' Invoice ' Item ' Price ' NetUnitPrice
    9. Double-click on the Amount element and you should see the mapping, represented graphically in the bottom pane
    10. In the status line of the graphical editor, select Arithmetic from the list box:
    11. To the right of the listbox, scroll until you see the FormatNum function
    12. Click on FormatNum, which will cause the function to be added to the graphical editor.  You may drag the box as desired
    13. Select the connection that binds the if/then/else to the Amount box by grabbing the arrow within the input of the Amount
    14. Release the drag of the connection while over the input to the FormatNum box.  This will reassign the output of the if/then/else to the input of FormatNum
    15. Create a connection between the output of the FormatNum box and the input of the Amount box.  You accomplish this by clicking within the output and releasing within the input (respectively).
    16. Save the modified mapping object
    17. Activate the changes
        a. In the left pane, select the Change Lists tab
        b. Navigate to the Standard Change List entry
        c. Right-click the Standard Change List entry and select Activate
        d. Select only MM2SUSInvoice if more than one item is available, and press the Activate button
    18. This will complete the required modification.

  • File Transport: Version conflict.

    Hi,
    I have a doubt on a particular scenario while transporting object from QA to PRD using File transport.
    I have exported a tpz file say 1.tpz from QA with say the following objects
    Obj_1(ver 1.0)
    Obj_2(ver 1.0)
    Obj_3(ver 1.0)
    Now before this 1.tpz is imported in PRD few more changes happend to Obj_3 and I exported again a file say 2.tpz
    Now this 2.tpz has only Obj_3(ver 2.0)
    Now the basis has by mistake Imported this 2.tpz file before importing the 1.tpz file. SO in my PRD the object Obj_3 is existing  with a advance version i.e 2.0
    Now my doubt is can we Import 1.tpz now in PRD and then again import 2.tpz ?
    I am having a feeling that we will definately get in version conflict. Even if I ignore the warning during transport and go ahead with this procedure of importing 1.tpz and then 2.tpz again, will it impact my scenarios.
    I am lookign for a quick suggestions.
    Regards,
    Rahul.

    Hi Rahul,
    If you import V1 file first & later V2, it will not impact on your scenarion & you wil be able to see latest object in PRD.
    But V2 is already imported so import of V1 may not be successful.
    You may generate a new export if possible & transport this. It should include all object with their lastest version.
    Regards
    Sushil

  • Resolving version conflict

    1)Developer1,(Client as Client1)creted Hello.java file chked in now the version is 1.0
    2)Developer2,(Client as -
    ) checked out synched edited Hello.java file chked in version is 2.0
    Now both the developers checked out the version2.0 Devloper1 cheked in while developer2 got checkin conflict.
    Assume that by some means he deleted client,he wont remeber what client name he has given. How to merge this conflict.

    How can he check-in and get a version conflict if he doesn't have a client? Checking in is only possible if you have a client.
    Message was edited by: Pascal Willemsen

  • Version conflict in PI QA system

    Hi All,
    We are facing version conflict issue in QA system.
    We transported a Mapping object from Dev to QA and after transporting it is giving Version conflict at QA.
    This thing happen because some user has edited mapping program at QA level and activated .
    We thought of transporting a deleted object first then the latest active version. But my doubt is that when we transport the same mapping program with same name PI will bring back object along with its history.
    Can anyone having any idea about how to resolve this conflict.
    Regards,
    Navneet

    Hi Ninu,
    Thanks.
    We activated the conflicting version from conflict tab and then transported the dummy changes from DEV to QA to verify it wont give version conflict any more.
    it worked fine and conflicting version which we activated at QA considered as latest version for transport.
    Regards,
    Navneet

  • What's all this "possible midi conflict", "missing extensions" jazz?

    Recently I installed Leopard, 2gb of Ram, and Pro 8 in my Powermac. I have an emagic amt8 and a motu 828mkII connected. I installed the latest motu drivers. No problem.
    A little later I installed the exact same thing on my friend's powermac, which is the same generation as mine. He has a motu 828mkII and an 8pre daisy chained to the mac. Every time we launch logic we get "possible midi conflict...old drivers..blah blah", and the "missing extensions...go to Pace website...blah blah..." After closing those boxes (often several times for the "possible midi conflict") logic launches and says "core midi not available", or some such.
    We've learned that we simply need to quit logic and relaunch and the problem usually goes away and everything works as it should. Sometimes I have to do the routine twice. This happens even if I quit logic and launch it the same day.
    Going to the Pace website didn't help. I could find no old drivers to remove. My friend's system used to have Pro Tools on it, but I think those drivers are gone. I've messed with audio/midi setup in utilities. I've gone to the library to try to find old drivers.
    I know other people have complained of similar problems. Can anyone shed any new light on this?

    Open Hard Drive go to library-> Audio-> Midi Drivers. Move drivers to Trash but don't trash.
    Now go to library->Audio->Plug-Ins->Components. Drag this folder to desktop & move contents of this folder to trash but again don't trash anything yet. Now still in the hard drive section go to your user file i.e the house logo with your name next to it. Go Library->Audio->Plug-Ins->Components & check this file is empty. It should be but if not do the same as with the previous component file. Restart the computer & try opening Logic. Hopefully it should work now. You'll have to decide whether you want to trash the drivers if you don't use them or if you want to get in touch with the third party company to open the iLock but for the time being Logic should work

  • XI 3.0 Version Conflict after SP 10 import

    My XI 3.0 integration builder shows a version conflict for IDOC adapter meta data after we have implemented support package 10.
    What needs to be done ?

    Hi Peter,
    We have this issue as well. not sure it is too much of an issue though.
    Cheers
    Colin

  • Version conflict while targeting a vi to RT engine

    When i  am targeting a vi to Labview RT engine the message "Version Conflicts between Host Labview and RT engines" is coming.
    I am using a CFP-2100 and want to run a vi on it. (No PC should be connected with it)
    After targetting how will i execute it on CFP? is it automatically executable?
    Please reply me
    --Alok Trivedi
    Pune
    -AL☼K

    Thanx for replying me so soon.
    I am still stucked with the problem.
    I have Labview 7.0 installed on my computer and where i am making a vi which is to b loaded into CFP - 2100.
    Here are other versions i am using.....
    Field point VI manager 3.1.0
    Field point Drivers 5.1.0
    Data socket for Labview Real Time 4.2
    Labview Real Time 7.1
    NI-Irda RT 1.0.1
    NI-Serial RT 2.5.4
    NI-VISA 3.2
    NI-Watchdog 2.1.2
    When i switch the execution target to RT engine for remote device and enter the machine IP address it shows me "Version Conflict while targeting a VI to RT engine".
    I talked to Rahul about this and he well told me how to repair version conflicts between Host machine and RT engine. I went to remote machine and by right clicking on "software" installed all the versions to remote machine according to the host machine.
    the interesting thing is here it's not showing any version mismatch all the versions shown above are same as the host machine......but whenever i try to target the execution to RT engine it shows the version conflict.
    now what all questionis running in my mind are :
    1. Why the version conflict is occuring?
    2. If I get succeed to targeting the execution of vi onto RT engine how would i install it to CFP, if i just copy and paste it via FTP how will it know what vi is to run? i think we'r missing some way to "install" the vi into CFP.
    3 What is "RT Communication wizard for".......why it makes 3 other vi's....
    4. what are the total ways to run a vi onto CFP
    Waiting for your reply...
    thanks again
    -Alok Trivedi
    Pune
    -AL☼K

  • Version conflict between XE's ODP and VS2005/ODT's ODP

    Suppose you've just built an application with VS2005, .NET Framework 2.0, and Oracle Developer Tools for Visual Studio .NET with Oracle10g Release 2 ODAC 10.2.0.2.20 which uses Oracle.DataAccess.dll version 2.102.2.20. You want to be able to run the application on a client machine that has an Oracle XE database installed locally. Perhaps you even require that the client machine runs the Oracle XE Client. Unfortunately, even with both there seems to be a version conflict regarding Oracle.DataAccess.dll. Can anyone say what are the best practices for such a situation?

    Situation:
    1) Oracle XE (database with/without client) installs with the following two files in the <ORACLEXE_SERVER_HOME>/BIN directory:
    Oracle.DataAccess.dll v10.2.0.100 (for .NET Framework 1.0)
    OraOps10.dll v10.2.0.100 (for .NET Framework 1.0)
    2) Applications built with VS2005, .NET Framework 2.0, and Oracle Developer Tools for Visual Studio .NET with Oracle10g Release 2 ODAC 10.2.0.2.20 use Oracle.DataAccess.dll v2.102.2.20 (for .NET Framework 2.0).
    3) The client machine will be missing the following two files vital to the application: Oracle.DataAccess.dll v2.102.2.20 (for .NET Framework 2.0), OraOps10w.dll v2.102.2.20 (for .NET Framework 2.0). These two files can be found on the development machine in the <ORACLE_ODAC HOME>/odp.net/bin/2.x  and <ORACLEODAC _HOME>/bin directories, respectively.
    Action:
    When installing the application on the client's machine, place copies of the two missing files into the client's <ORACLEXE_SERVER_HOME>/BIN directory, overwriting the existing Oracle.DataAccess.dll v10.2.0.100 (for .NET Framework 1.0).
    Result:
    The application performs as expected.
    My immediate concern is that the client may object to replacing the existing Oracle.DataAccess.dll v10.2.0.100 (for .NET Framework 1.0). What are the best practices for such a situation?

  • Version conflict resolution failure - catch 22

    Hi,
    I have a situation where I am trying to delete a DIRECTORY object (a receiver determination for example), but when I attempt to activate the change list a version conflict is reported.
    When I attempt to resolve the conflict through the editor, I always get a 'MERGE RELATION IS NULL' error and cannot resolve the conflict and therefore cannot delete the object.
    I am using SP 13.
    Any help will make me VERY happy !
    Cheers,
    Guy

    Hi,
    Use TCODE : SXMB_IFR then Exhange Infrastructure Browser Will Display then
    GoTo--> Administration by using PISUPER or XISUPER ->select ID->Select Administration of Locks and Caches -> Select Lock Overview>Delete if ur userid is display.
    Then Refresh Cache once.
    Plz allot points if u satisfy with the answar....
    With Regards,
    Mahesh

  • How do I correct version conflicts between host and RT engine?

    I was running LabVIEW RT7.0 on a host PC (WinXP) and PXI-8145 system. I installed LV7.1 and LVRT7.1 on the host. However, the software versions in MAX still report as 7.0
    I would like to upgrade to 7.1 on my 8145-RT. I cannot run 7.1 on the host and target the 7.0 RT engine (results in version conflict). Version 7.0 is installed on C:, but 7.1 is installed on D: due to space.
    How can I get MAX to recognize my latest version (which should allow my to download it to the PXI)?
    Thanks.
    Laine

    Thank you for the response.
    C:\RT Images contains only a single folder for NI-PAL
    However, I backed it up and copied the RT Images folder from D:, but still the same effect (MAX thinks 7.0 is the latest LabVIEW version).
    D:\RT Images\LabVIEW\7.0 contains subfolders and install scripts (e.g., 7002.rts)
    D:\RT Images\LabVIEW\7.1 contains subfolders but no install scripts. Also, there are many fewer files in these subfolders than in the 7.0 folder. I'm worried about trying to manually install from the 7.1 folder.
    Any other suggestions? Thanks.
    Laine

  • Target fieldpoint connection failed due to version conflicts

    I have set up a small network of fieldpoint (fp-2015) and laptop with Ethernet. Then, I have succesfully configured this fp with MAX and downloaded the iak file to it. Now, I want to target the labview RT of this fp. However, the the connection failed with following message "Version Conflicts between host labview and RT Engine". I'm using Labview 7.1 released in August.

    It sounds like the FP-2015 that you have has an older version of software on it (probably LabVIEW 7.0). To upgrade the software on the FP-2015, first launch Measurement & Automation Explorer. Locate the FP-2015 under Remote Systems. Right click on the software item and select Install Software. This will allow you to install the new software image and upgrade the controller to LabVIEW 7.1. Note: You will need FieldPoint Explorer 4.1 which shipped with LabVIEW 7.1. If you have an older version of FieldPoint Explorer, it will not have the 7.1 image for the FieldPoint controller.
    Regards,
    Aaron

  • I have a 2007 MacBook and I want to install the latest possible version of OS X. What version is that?

    Like I said, I have a mid-2007 MacBook (note that it is NOT a MacBook Pro) and I want to install the latest possible version of OS X on it. I would like to know what the latest version that it can handle is. I know that the latest version of OS X is Mavericks, but I'm pretty sure that won't work on it, so will Lion or Snow Leopard?

    System requirements for OS X Lion
    OS X Lion (10.7) - Apple Store

  • Version conflicts between host labview and RT engine

    there is problem that i cannt switch target to feild point. It said that "version conflicts between host labview and RT engine" . But my labview is version 7.0 and the real time module is version 7.0 too. Anyone can give me hand? Thanks

    Depending on your version of MAX, you should be able to change the version on the FP (in remote systems). If you can't do it in 3.0, try upgrading to 3.1 (you will have to search for it on the site). If that doesn't work, you can try resetting to factory default and then see if you can do this.
    Another tip, which for some reason seems to help, is updating the OS\Run-Time Engine when windows is in safe mode.
    Try these and see if they help.
    BTW, as a tip for next time, you're more likely to get a good answer for something like this if you post in the FieldPoint board.
    Try to take over the world!

  • SDM version conflict error

    Hi guys,
    I'm trying to apply a note on a portal with MSSQL on a Windows system using SDM.
    When I run SDM from
    usr\sap\<sid>\<instance>\SDM\program\RemoteGui.bat
    and enter the password(which I know is correct) I get this error
    Request for Logon rejected because the version conflict- Server version 1.70, Gui version 1.60
    How can I upgrade the version of Gui?
    J2ee engine has  SP7 on 7.0
    I would really appreciate it if anyone can help me here
    Thank you

    Have you upgraded the database or OIM to 9.1.0.2.
    You can ignore this as per Oracle guys told me.

Maybe you are looking for

  • Can I use a Time Capsule on a hard wired iMac and get wireless to other devices?

    I have a 6 year old iMac that does not have an airport extreme card.  I have it connected to a cable modem ARRIS model TM502G which is also the VOIP for my telephone.  My question is, if I buy a Time Capsule, will I be able to have wi-fi for other de

  • Macbook pro 1,1 2006 10.6.8 TRIM utility

    Hi folks Back again. So, I'm running a first gen Macbook Pro, in good health. I have a macpro at home and an i7 imac at home, so the heavy lifting is taken care of, I want to upgrade my macbook, to give it a couple of extra years (hopefully) for ligh

  • Case function in where clause

    i insert the below rows in a table cash_book. PRJ_CODE PRJ_NAME 1203 SHIFA 1203 SHIFA 1203 SHIFA 1202 FATIMA 1202 FATIMA 1203 SHIFA if i select 1202 code then return 1202 code rows, if i select 1203 then returns 1203 code rows, if i select other than

  • Problem with executing script in sql*plus

    I have Oracle Database 10g Express Edition Release 10.2.0.1.0 - Production installed And I have a script for generating Packages with more than 1000 rows. when I try to execute I get this: SQL> @c:\gen_pkg\gen_pkg.sql Package created. 977 The Package

  • How does one highlight Text in Imail messages

    I understand how one uses the "Fonts" of "Colors" Icon on the message dialog box to change the font color of selected text in a message so it stands out, but have NOT FIGURED OUT how one can instead (or in addition) "highlight" the text. By that I me