Power injector for 1300 bridge

It is possible to use a AIR-PWRINJ-BLR1 power injector with a 1300 series bridge?  I know the BLR2 injector is the proper one but need to know if they are at all compatible.

Hi,
AIR-PWRINJ-BLR1 = ONLY for 1410 Bridges.. and should not be used with 1310 Bridges..
lemme know if this answered your question..
Regards
Surendra
====
Please dont forget to rate the posts which answered your question and mark it as answered or was helpfull

Similar Messages

  • Can not find Power Injector for wap2000.

    Hello everybody.
    Not long ago i was bought Cisco wap2000 access point for small business, and now the problem is to find power injector for this device.
    I am already tried to use AIR-PWRINJ3, but access point did't turn on.
    Why?
    Which power injector should i use with this device?
    Thanks.
    PS.
    Please, don't judge me, for my bad english. =)

    I would think that:
    http://www.google.com/products/catalog?hl=en&biw=1168&bih=723&q=cisco+AIR-PWRINJ4%3D&um=1&ie=UTF-8&tbm=shop&cid=1924636136971570879&sa=X&ei=oGf_TcGfHoy40AH2xLDjAg&ved=0CIMBEPICMAU#
    should work, Cisco should be able to confirm . . .
    If not then I would try:
    http://www.versatek.com/products/cisco_power_injector.htm?_kk=cisco%20PoE%20injector&_kt=90d05a21-707c-456a-8dc9-c92b9a334f1b&gclid=CPnpz-nlxKkCFUqM5godGH4Mmw
    I know your original post was in January and you may have created that 100m power cord but I hope this helps others.

  • Power Injector for WAP200

    Hello
    I need your advice on whether power Injector for Aironet AP’s can be also used for SB WLAN products.
    Is AIR-PWRINJ4= compatible with WAP200??
    Any advice would be very appreciated.
    Best Regards,
    Allan Kim

    Hi, My name is Eric Moyers. I am a Network Support Engineer in the Cisco Small Business Support Center.
    Currently there are no Cisco/Linksys POE approved injectors for this device or any of our other small business products. Our recommendation for powering these units are to use either the supplied power adapter or a POE Switch that is 802.3af compliant. Any of our switches with a P in the model number would be perfect. Here is a link for you to our switches.
    http://www.cisco.com/cisco/web/solutions/small_business/products/routers_switches/index.html
    While it is possible for that Cisco Enterprise Injector to mentioned above should work, It has just not been tested so we can not completely recommend it.
    Hope this helps.
    Eric Moyers
    Cisco Network Support Engineer
    1-866-606-1866

  • Power Injector for 1310 wireless bridge

    Hello,
    We have a failed power injector on a 1310 series bridge. Will the "Power Injector LR" from a 1410 series bridge work on the 1310?
    Thank you,
    Matt

    No... both have a different output and should not be used interchangeably.    
    See this post by Surendra:
    https://supportforums.cisco.com/message/3280050#3280050
    Thanks,
    Scott
    Help out other by using the rating system and marking answered questions as "Answered"

  • Power Injector for Airport Extreme (Generation 5)

    Hello.
    Is there any support for using Power Injector (PoE) instead of the supplied power apdater to run Airport Extreme.
    Cheers
    Mr Apro

    Sorry, but Power over Ethernet is not supported on the AirPort Extreme.

  • Power Injector for a AP541N?

    Hi,
    Is there a power adaptor that you can purchase to use with the AP541N.
    Thanks
    Lisa

    Cisco Unified IP Phone Power Injector
    http://www.cisco.com/en/US/prod/collateral/voicesw/ps6788/phones/ps379/ps6951/product_data_sheet0900aecd804b4649.html
    Q&A:  Cisco Unified IP Phone Power Injector
    http://www.cisco.com/en/US/prod/collateral/voicesw/ps6788/phones/ps379/ps6951/prod_qas0900aecd804b4694.html
    Please don't forget to rate useful posts.  Thanks.

  • Power injector compatibility - air-pwrinj4

    Does anyone know if the air-pwrinj4 (power injector for the 1250 and 1140 series) will power a 1240 and/or 1210 series AP?

    Great, this will help with an AP upgrade this weekend. Thanks!

  • Power injectors don't work with APs

    Has someone got experience on cisco power injectors for Aironet APs.
    I bought 3 injectors, and 3 power supplys(injectors need power supply, but don't come with the boxes) from cisco.
    I connected a switch(2960) port to the port ‘to network’ on the power injector, and connected a AP(1142N) Ethernet port to the port ‘to Device’ on the power injector.
    The power injector was powered on by the DC supply. But the AP couldn't be powered on by the injector, and the switch port also showed 'noconnect'.
    No particular commands setup on the switch port’s settings.  I tried the switch port auto-auto and 100-full, Vlan access and trunk, but no luck with the injectors.
    Connected the same power supply to the same AP, used the same switch port and same cables, the AP worked fine with the switch.
    Thought of faulty injector, but it's weird that all 3 new purchased injectors are faulty.
    Am I doing anything wrong? do I need to put any commad on switch interface to use power injector?(I cannot believe that)  or just had bad luck of having 3 faulty injectors?
    Please help.  Thanks a lot.

    20W Single Port Midspan
    Have a look at the link above.
    Thanks for the ratings.

  • 1300 Series Access Point/Bridge Power Injector - Using power over ethernet

    Can I use power over ethernet to supply the Injector with power?

    Hi Mikael,
    Sorry, this will not work. Have a look at these specs;
    1300 Series Power
    Power
    The access point/bridge receives inline power from the Cisco Aironet Power Injector (hereafter called the power injector). Dual-coax cables are used to provide Ethernet data and power from the power injector to the access point/bridge. The power injector is an external unit designed for operation in a sheltered environment, such as inside a building or vehicle. The power injector also functions as an Ethernet repeater by connecting to a Category 5 LAN backbone and using the dual-coax cable interface to the access point/bridge.
    The power injector is available in two models:
    Cisco Aironet Power Injector LR2 standard version (included with the access point/bridge)
    48-VDC input power
    Uses the 48-VDC power module (included with the access point/bridge)
    Cisco Aironet Power Injector LR2T optional transportation version
    12- to 40-VDC input power
    Note The power injector and the power module must not be placed in an outdoor unprotected environment. The power module must not be placed in a building's environmental air space, such as above a suspended ceiling.
    http://www.cisco.com/en/US/products/ps5861/products_installation_guide_chapter09186a008079b93b.html#wp1051840
    Dual coaxial cable to run from the power injector to the 1300. See attached notes:
    Cisco Aironet 1300 Series
    Cisco Aironet 1300 Series Access Point/Bridge Power Injector
    The Cisco Aironet 1300 Series Outdoor Access Point/Bridge Power Injector,converts the standard 10/100 BaseT Ethernet interface that is suitable for weather protected areas to a dual F-Type connector interface for coax cables that are more suitable for harsh outdoor environments. The Power Injector also provides power to the outdoor unit over the same cables with a power discover feature and surge protection. To support longer cable runs from your wireless network switch or router, the Power Injector LR is designed to accommodate up to a 100 meter coaxial cable run plus 100 meters of indoor cat5 cable?enabling total cable runs up to 200 meters. The Cisco Aironet 1300 Series Outdoor Access Point/Bridge ships with the Power Injector LR2 and an AC power supply.
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_data_sheet09186a008022551d.html
    Cisco Aironet 1300 Series Outdoor Access Point/Bridge Hardware Installation Guide
    Ethernet Ports
    The access point/bridge dual-coax Ethernet ports consists of a pair of 75-ohm F-type connectors, linking the unit to your 100BASE-T Ethernet LAN through the power injector. The dual-coax cables are used to send and receive Ethernet data and to supply inline 48-VDC power from the power injector to the access point/bridge.
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_installation_guide_book09186a00804d3095.html
    AIR-PWRINJ-BLR2
    F-Type Connectors
    Dual coaxial cable carries full-duplex Ethernet, DC power, and full-duplex console port (RS-232 connection)
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_data_sheet09186a00802252e1.html
    Hope this helps!
    Rob

  • Show power-injector issue (Bridge 1410)

    Hello All,
    We have set up a point to point link using two 1410 wireless bridges. The connection has been working for more than 1 year without a major issue.
    This morning, we have noticed  that on one of the bridge the result of the show power-injector is as follows:
    #sh power-injector
    =========== Power Injector Statistics ===============
    ==Power Injector port 0 is disabled
    ==Power Injector port 1 is disabled
    ==Power Injector port 2 is disabled
    ==Power Injector port 3 is disabled
    ==Power Injector port 4 link down
    ==Power Injector port 5 is disabled
    ==Power Injector port 6 is disabled
    Both bridges are associated. The problem is that you can't ping the bridge that displayed the aforementioned command through its power injector. We have even replaced the power injector with a  new one and we are still facing the same issue.
    Both bridges are using the following image c1410-k9w7-mx.124-21a.JY.
    Did someone has encountered the same issue and how did he/she fix it ?
    Thank you,

    Hi,
    Actually port on the power injector switch are in auto-duplex and auto-speed mode
    you need to ensure external devices which you connected to power injector switch ports are not hardcoded in full-duplex, they needed to be in auto-duplex mode.
    because in result of duplex mismatch you connection could be slow down and even ports may shutdown.
    and also check both bridge with the latest firmware release
    Cisco Aironet equipment operates best when you load all components with the latest version of the software. 
    You can download the latest software and drivers from the Wireless Downloads Page ( registered customers only) . 

  • Report for Power Injector State

    I need a report for all Power Inyector installed with a AP, how i have this information in a report?
    please i need help

    The is no way to detect if your using a power injector or not.  There are commands to enable if your using a power injector, but that doesn't mean its not connected to a PoE switch.  
    That would be a manual process of going to each ap and looking.

  • Need help on Aironet 1300 bridges

    Greeting,
    We have just upgraded two Aironet 1300 bridges (from cisco 350) on two buildings about 100 yards apart. They are only running as bridges. One is set up as root bridge and another one is setup as non-root bridge. Root bridge is in the main building direct connect to Cat 4506. For some reason the root bridge has some intermittant problem connect to the network. We are running the IOS 12.3(8). We changed the cable but the problem still occured. Everytime we have to reboot the root bridge in order to get it back. but all the interfaces in the root bridge show " up / up" prior to reload. The "show tech" looks fine on the root bridge. Any suggestion? Shall I change root bridge to workgroup bridge?
    really appreciate for any helps,
    Gene

    Hi Steprodr,
    I just need to clearify that the power injector is on the non-root bridge? I think the power are fine on both bridges when the problem occured. We used cisco 350 bridges before the upgrade. So the cable and port are still remain the same. The problem is more going towards from root bridge come back to Cat 4506 because both root and non root bridges can ping each other when the problem occured.
    thanks,
    Gene

  • Aironet 1310, power injector and poe cable

    Hello,
    Can the power injector delivered with aironet 1310 be supplied by a PoE RJ45 cable rather than the traditionnel DC adapter?
    The problem is, i thought Aironet 1310 was PoE. Which means it can be power supplied by a rj45 cable.
    But, when i openned my brand new 1310 box, i realized that 1st, it needs that Power Injector to work and that 2nd, Power injector needs a power supply...
    Usually when i buy a PoE access point, I just plug in my PoE rj45 cable and its power supplied :)
    Anyway, i hope there's an issue for this because where the 1310 should be placed, there's only a PoE rj45 cable arriving.
    Thanks in advance,
    lachapelle

    Hi lachapelle,
    Sadly the 1310 cannot be powered by PoE ,but, the Power Injector can be up to 100 meters away from the unit.
    Dual coaxial cable to run from the power injector to the 1300. See attached notes:
    Cisco Aironet 1300 Series
    Cisco Aironet 1300 Series Access Point/Bridge Power Injector
    The Cisco Aironet 1300 Series Outdoor Access Point/Bridge Power Injector,converts the standard 10/100 BaseT Ethernet interface that is suitable for weather protected areas to a dual F-Type connector interface for coax cables that are more suitable for harsh outdoor environments. The Power Injector also provides power to the outdoor unit over the same cables with a power discover feature and surge protection. To support longer cable runs from your wireless network switch or router, the Power Injector LR is designed to accommodate up to a 100 meter coaxial cable run plus 100 meters of indoor cat5 cable?enabling total cable runs up to 200 meters. The Cisco Aironet 1300 Series Outdoor Access Point/Bridge ships with the Power Injector LR2 and an AC power supply.
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_data_sheet09186a008022551d.html
    Cisco Aironet 1300 Series Outdoor Access Point/Bridge Hardware Installation Guide
    Ethernet Ports
    The access point/bridge dual-coax Ethernet ports consists of a pair of 75-ohm F-type connectors, linking the unit to your 100BASE-T Ethernet LAN through the power injector. The dual-coax cables are used to send and receive Ethernet data and to supply inline 48-VDC power from the power injector to the access point/bridge.
    Power
    The access point/bridge receives inline power from the Cisco Aironet Power Injector (hereafter called the power injector). Dual-coax cables are used to provide Ethernet data and power from the power injector to the access point/bridge. The power injector is an external unit designed for operation in a sheltered environment, such as inside a building or vehicle. The power injector also functions as an Ethernet repeater by connecting to a Category 5 LAN backbone and using the dual-coax cable interface to the access point/bridge.
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_installation_guide_book09186a00804d3095.html
    AIR-PWRINJ-BLR2
    F-Type Connectors
    Dual coaxial cable carries full-duplex Ethernet, DC power, and full-duplex console port (RS-232 connection)
    From this link:
    http://www.cisco.com/en/US/products/ps5861/products_data_sheet09186a00802252e1.html
    Hope this helps!
    Rob

  • AP 1300 Bridge Design/Change

    I have a client w/ an AP 1300 bridged across two buildings (Building A Building B).  Past history - Building A had Internet, Building B did not.  The link was constantly going down, so it was turned off and both locations now have Internet.  From time to time, Building B's Internet goes down (cheaper service) and would like to resurrect the wireless for failover.  There is zero documentation and we found the Air-PWRINJ-BLR2 unit, but cannot find the actual AP unit without climbing into attics.  Is this the unit we use to configure it?  It has a console port - Also the IP's configured on the unit appears to be on the same LAN segment as Building A (192.168.10.250 & 192.168.10.251).  I'd like to place both ends of the wireless bridge (Building's) into a DMZ port and static route route.  How the heck can I accomplish this if the bridge is configured w/ the same LAN segments as Building A?  I have a router w/ multiple ports ready to plug in.
    I just need Building B to be able to access the Internet via Building A if their default Internet goes down.
    Building A Network
    192.168.10.0/24
    Building B Network
    10.20.190.0/24

    Hi
    yes the console port on the power injector is is console port for the AP. probably the best way to recover the bridge is to connect the 1310 to a laptops etherernet port and use the console port to learn the IP of the 1310 then manage the 1310 with the GUI it can be done with the CLI but if you have not done a wireless bridge before stick with the GUI. Both 1310's need to be on the same subnet, this is for management not for bridging. the bridging is at level 2 unless you use VLANS but with the routers that should not be an issue. once you have configured the Root router save the config and use it to to congigure the non-root router changing the IP address and the role to Non Root. plug the network cables into the the apropriate router ports and you should be set.
    this is assuming you know the userid/passwords for the AP's  the default was Cisco/Cisco.
    if the antennas are alinged your bridge should be reliable.
    based on the signal level between the AP's i would disable the B data rates use the G data rates and possibley disable the higher data rates if the radio stats show to many retrys, mor than 10%.
    Bill

  • 1300 Bridge fa0 port status down

    I have a remote 1300 bridge whose fa0 port consistently goes down after working well for over a week. It shows the port as admin up but line status down - no carrier. It plugs directly into a 1200 ap. I have tried to hard code the speed and duplex but the option to hard code the speed is not available. Any ideas?

    Hi
    yes the console port on the power injector is is console port for the AP. probably the best way to recover the bridge is to connect the 1310 to a laptops etherernet port and use the console port to learn the IP of the 1310 then manage the 1310 with the GUI it can be done with the CLI but if you have not done a wireless bridge before stick with the GUI. Both 1310's need to be on the same subnet, this is for management not for bridging. the bridging is at level 2 unless you use VLANS but with the routers that should not be an issue. once you have configured the Root router save the config and use it to to congigure the non-root router changing the IP address and the role to Non Root. plug the network cables into the the apropriate router ports and you should be set.
    this is assuming you know the userid/passwords for the AP's  the default was Cisco/Cisco.
    if the antennas are alinged your bridge should be reliable.
    based on the signal level between the AP's i would disable the B data rates use the G data rates and possibley disable the higher data rates if the radio stats show to many retrys, mor than 10%.
    Bill