Power Redundancy problem for cisco 3750 stack switches

Hi Team,
I have installed and configured cisco 3750X series switches in stackwise. Those are having dual power supply.
Power redundancy test performed:
1. Removed one of the power supply and inserted it back.
2. once the first power supply is ready, removed another power supply and switch got rebooted.
please find the below stack-power output:
JP2-RDC-DIS-02#sh stack-power detail
Power Stack           Stack   Stack    Total   Rsvd    Alloc   Unused  Num  Num
Name                  Mode    Topolgy  Pwr(W)  Pwr(W)  Pwr(W)  Pwr(W)  SW   PS
Powerstack-2          SP-PS   Stndaln  700     477     223     0       1    2
Powerstack-1          SP-PS   Stndaln  700     477     223     0       1    2
Power stack name: Powerstack-2
    Stack mode: Power sharing
    Stack topology: Standalone
    Switch 2:
        Power budget: 223
        Power allocated: 223
        Low port priority value: 22
        High port priority value: 13
        Switch priority value: 4
        Port 1 status: Not connected
        Port 2 status: Not connected
        Neighbor on port 1: 0000.0000.0000
        Neighbor on port 2: 0000.0000.0000
Power stack name: Powerstack-1
    Stack mode: Power sharing
    Stack topology: Standalone
    Switch 1:
        Power budget: 223
        Power allocated: 223
        Low port priority value: 22
        High port priority value: 13
        Switch priority value: 4
        Port 1 status: Not connected
        Port 2 status: Not connected
        Neighbor on port 1: 0000.0000.0000
        Neighbor on port 2: 0000.0000.0000
Can anyone help what went wrong here?
Thanks
Manish

Cosmetic bug
CSCui21029    3750X Stack no standalone stays in running configureation as standalone
Symptom:
When you are configuring a 3750x stack and initially putting it into a stack ring topology by configuring the following.
Switch(config)#stack-power switch 1
Switch(config-switch-stackpower)#sta
Switch(config-switch-stackpower)#no stan
Switch(config-switch-stackpower)#no standalone
You will see that in the running configuration it shows up as standalone mode
stack-power switch 1
switch mode: standalone
stack-power switch 2
switch mode: standalone
Conditions:
3750X stacks with any license level
Workaround:
none

Similar Messages

  • I have a problem for cisco catos 4232 switch.

    i have entered the enable mode in cisco catos 4232 switch,but always there have been a remarks appearing all the time as follows:
    2006 Feb 23 14:23:34 %SYS-4-P2_WARN: 1/Host 02:01:00:00:00:00 is flapping betwee
    n port 3/34 and port 3/33
    why?
    thank you!
    Best Respects!
    guominquan

    Hi Friend,
    The message indicates that your Catalyst 4500/4000 switch has learned a MAC address that already exists in the content-addressable memory (CAM) table, on a port other than the original one. This behavior repeatedly occurs over short periods of time, which means that there is address flapping between ports.
    If the message appears for multiple MAC addresses, the behavior is not normal
    If the error message appears for one or two MAC addresses, locate these MAC addresses in order to determine the cause. Issue the show cam mac_addr command in order to identify from where these MAC addresses have been learned. In this command, mac_addr is the MAC address that the error reports as flapping.
    After you determine between which ports this MAC address is flapping, track down the MAC address. Connect to the intermediate devices between your Catalyst 4500/4000 and the device that has the problem MAC address. Do this until you are able to identify the source and how this device connects to the network.
    Note: Because the MAC address is flapping between two ports, track down both of the paths.
    These are other issues that can cause this message to appear
    1) Server NIC redundancy problem
    2) HSRP
    3) EtherChannel misconfiguration
    4) Host reflects packets back onto the network
    Check this link for complete details of this problem and how to troubleshoot
    http://www.cisco.com/warp/customer/473/176.html#subtopic1k
    HTH, if yes please rate the post.
    Ankur

  • Magic number mismatch: bad mzip file in 3750 stack switch

    Hi All can anybody help me in this error msg
    "magic number mismatch: bad mzip file"
    I am trying to upgrade the switch  with"c3750e-ipbasek9-tar.122-55.SE5.tar" in 3750 stack switch it is  showing this error msg while booting
    thanks in advance

    Hi,
    The reason you are getting this error message on the switch is a corrupt or wrong IOS image "c3750e-ipbasek9-tar.122-55.SE5.tar".
    If the switch is in rommon mode, and you have any other image in the switch, boot it using that image. Once the switch is up, download and copy the correct IOS image once again on the switch and try to upgrade.
    If you need help in finding the correct IOS image, give me the exact switch model number, i will help you with that.
    But forsure the image is wrong or corrupt and that is why you are getting this error.
    Thanks
    Ankur
    "Please rate the post if found useful"

  • Help for Cisco 2960 48port switch not working

    I had downloaded the template from the wiki for Cisco 48 port switch,unfortunately, it seems doesn't work.Are there other places where i can find WS-C2960S-48TS-L switch ? I also search the internet to find most people like to buy cisco product at Router-Switch.com with reliable quality and competitive price.Can give me the advice if i want to buy switch on this website ?

    Please read over this FAQ and see if any of it might apply to you.
    http://www.blackberryfaq.com/index.php/Errors_syncing_the_BB_with_Desktop_Manager
    1. If any post helps you please click the below the post(s) that helped you.
    2. Please resolve your thread by marking the post "Solution?" which solved it for you!
    3. Install free BlackBerry Protect today for backups of contacts and data.
    4. Guide to Unlocking your BlackBerry & Unlock Codes
    Join our BBM Channels (Beta)
    BlackBerry Support Forums Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • Etherchannel two cisco 3750 stacks for iscsi?

    I have two sites connected by 96 strands of fibre. At each site I have an IBMv7000 relicating to the other one. For iSCSI traffic I have two Cisco 3750 switches, each are in 2 switch stack. 
    SAN A                         Fibre Link                          SAN B
            |                                                                        |
    Cisco Stack A =========================Cisco Stack B
            |                                                                        |
            |                                                                        |
    iSCSI Clients                                                       iSCSI Clients
    My question: Is it ok to connect the the two stacks with etherchannel using the fibre links? Will is provide the necessary redundancy, if one of the interfaces goes down?

    What model numbers of 3750 are you using?
    What is the distance between the stacks as this will dictate your fiber run modules.

  • MAC address flapping on 2 x Cisco 3750 (Stacked)

    Hi All,
    I am having some issue with my connectivity.
    The setup with HP virtual connect (VC) is as below:
    Server A NIC 1 -- VC 1 -- Switch A
                 NIC 2 -- VC 2 -- Switch A
    Server B NIC 1 -- VC 1 -- Switch A
                 NIC 2 -- VC 2 -- Switch A
    The VLAN configuration are done on individual NIC card on the servers and the switchport on Switch A facing the VC connect are all on trunk mode.
    Currently I am seeing MAC address flapping on my Switch. The switches are CISCO 3750 and are being stacked so it appears logically as 1 switch.
    Any idea what might be the problem?
    Below is an output of the flapping on the switch.
    %SW_MATM-4-MACFLAP_NOTIF: Host xxxx.xxxx.0637 in vlan 1 is flapping between port Gi2/0/3 and port Gi2/0/5
    %SW_MATM-4-MACFLAP_NOTIF: Host xxxx.xxxx.46eb in vlan 1 is flapping between port Gi1/0/5 and port Gi1/0/7
    %SW_MATM-4-MACFLAP_NOTIF: Host xxxx.xxxx.661d  in vlan 1 is flapping between port Gi2/0/15 and port Gi2/0/7

    Hi,
    Problem of MAC FLAP could resolve by following methods:.
    Check with the server providers to see if the OS and server platform support 'NIC' Teaming (NIC Bonding).
    FYI - NIC teaming allows users to group two or more physical NICs into a single logical network device called a bond. Once a logical NIC is configured, the virtual machine is not aware of the underlying physical NICs. Packets sent to the logical NIC are dispatched to one of the physical NICs in the bond and packets arriving at any of the physical NICs are automatically directed to the appropriate logical NIC. If one of the underlying physical NICs is broken or its cable has been unplugged, server will detect the fault condition and automatically move traffic to another NIC in the bond.
    Hope that help
    If helpful do rate
    Ganesh.H

  • Visibility of 3750 Stack Switches on SCH Portal

    We have implemented Smart Call Home in one of our customer network. Customer has 34 3750 switches configured in stack. We have done SCH configuration for all 34 devices, problem over here is on SCH portal under “Global Summary Report” only 17 switches are reflecting however in “Device Report” all 34 devices are reflecting.
    Can you please confirm/suggest to whom we can coordinate to resolve “Global Summary Report” discrepancy issue.

    When a stack boots, each stack of switches determines a master switch. The master switch is the switch handling coordination for all of the other switches in the stack and outside communication.
    It looks like the global summary report is reporting only the master switch for the stack. This makes sense to me. All of the other switches in the stack are suppose to be invisible to the outside world and the stack is supposed to operate as a single virtual switch. Since it is a virtual switch, each virtual switch should be counted once as a single entity.
    All of the devices in the stack are available for view if you drill down, but from a Smart Call Home view, only the stack master is communicating with Smart Call Home.
    But the bottom line is this is only software and can be written differently if it is too confusing to the customer.

  • 3750 Stack Switch Issue

    Hi
    I have Stack of 7 3750 Switches. In that Switch 1 is master with 15 Priority and other switches are Member but because of some reason switch 1 rebooted and then Switch 2 becomes Master because it’s having 14 Priority.
    We have 2 uplinks which connected on switch 1 (1/1/1) and switch 6 (6/1/1) Tengig port. Also we have 4 AP connected on switch 6.
    So we observed that the Switch 1 came up and after that 3 AP is disconnected from WLC. if we disconnect the uplink port on Switch 1 (1/1/1) AP will connect the WLC and using uplink 6/1/1 but if we connect uplink port 1/1/1 and disconnect the uplink port 6/1/1 all 4 AP will disconnect from Network.
    We try to connect the Uplink 1/1/1 to Switch 1 other port 1/1/2 but face the same issue. So we reconnect the port 6/1/1 and used the same link which connect on 1/1/1 to switch 7 (7/1/1) and AP will connect on WLC. So as per this troubleshooting we thought some issue with Network Module or Switch of Switch1.
    So we Swap the Network module between Switch1 and Switch7 and connect the uplink on 1/1/1 but face the same issue and if we connect the same uplink on Switch 7 Ap connect to WLC.
    So we thought that Switch is having issue. But before raising an RMA for Switch we observer 1 more thing that. Earlier that when the Switch 1 is Master all 4 AP's connected to WLC and working fine but when the Switch1 became rebooted and Switch2 became Master issue started. So we rebooted the Switch 2 and make switch master and found that while connecting on port 1/1/1 of Switch port AP's are able to connect to WLC and Issue resolved.
    So I wants to know that is there any requirement that If the high priority switch rebooted and after came up it should not be Master then connected uplink will not work.
    Also let us know what’s happen if the high priority switch came up in network. Means it’s will became Master or Menber.

    Just now i Found one bug which is matching on our issue.
    3750x stack fails to update ARP table after reboot causing traffic loss
    BUG ID:-CSCtz98066
    Symptoms: When the master switch (Switch A) is reloaded or loses power and
    rejoins the stack as a member switch, any traffic stream being sent through
    Switch A is unable to be received by the destination because the newly joined
    member is not able to establish an ARP entry for the next hop router/switch.
    Debugs confirm that Switch A does not send a GARP/ARP for the next hop, though
    traffic continues to be sent to the switch.
    Conditions: The symptom is observed when only Switch A has a physical
    connection between the source and destination router/L3 switch. The newly
    elected master (Switch B) does not.
    Workaround: Ping destination from Switch A, forcing ARP request/response.
    Also affected version is 12.2(58)SE and15.0(1)SE2 and we are using IOS 12.2(58)SE.
    So we are going to upgrade the devices by this weekend with IOS 15.0(2)SE5.
    Will update you once we upgraded the switches.

  • How to set up VLANs for Cisco SG500 - 28 switch

    Hi,
    First of all, this is my first post in here, I hope someone can help me, and please be patient since I am very little experienced.
    OK, so let me explain you the scenarion that I am facing and hopefully someone will be able to help me.
    We have a Cisco SG500 - 28 port gigabit switch in our workplace.
    Our goal, is to create 3 VLANs and seperate the networks between different departements.
    VLAN1 (which is the default VLAN in the switch) - will be used for IT department and the management.
    VLAN100 - will be used for business .
    VLAN200 - will be used for guests who need to connect to the internet through WiFi.
    I have created VLAN100 and VLAN200, and VLAN1 is there by default.
    I want to use port 13 for VLAN200 and to connect the Wifi access-point there.
    The uplink is in port 25.
    I would be glad if you could explain me the stuff first in a abstract more general level, and then we can look at the specific scenario that we have.
    The Cisco SG500 - 28 gets internet from a Sophos UTM 9 router.
    I will need to take care of inter-VLAN routing as well, and subnet, and DHCP
    Thanks in advance,
    Kindest regards,
    D

    Hello Desmond,
    You have two different options:
    Option 1:
    Configure Sg500 switch as a Layer 2 switch and let the Sophos firewall do all the Layer 3 routing along with internet access. If you choose this option, then, you need to configure your uplink port as a trunk port and allow all 3 vlans to pass through. Also, you need to make sure that the Sophos device supports VLANs and trunking (or at least sub interfaces and create sub interfaces for each vlan). Also, all LAN devices will have the respective sub-interface/VLAN interface IP on the Sophos as their default gateway.
    Option 2:
    Configure SG500 switch as a Layer 3 device and configure intervlan routing to manage internal network traffic locally and send just the internet traffic to Sophos device.
    You need to create Layer 3 interfaces for VLAN1, VLAN100, and VLAN200 on SG500 and then make those Layer 3 interfaces default gateway for respective VLAN.
    You can configure the uplink port as an access port in one of the VLANs.
    Make sure that the Sophos device has an IP on the same subnet as the VLAN you chose for the uplink port.
    You also need to enter static routes on the Sophos device for the remaining two subnets on the SG500 (next hop address pointing to the IP address of the VLAN that the uplink port belongs to).
    Also, on the SG500, you need to configure a default route, next hop address pointing to the Sophos interface IP address.
    Hope this helps.
    Nagaraja

  • Reverse SSH not working for Cisco 3750.Plz help.

    Hi,
    I have configured the reverse ssh mentioned on the cisco document:http://www.cisco.com/en/US/docs/ios/12_3t/12_3t11/feature/guide/gt_rssh.html#wp1051457.
    But now I am running into the issue that When I  issue command ssh -l alex:rotary1 192.38.6.8 from the cli of the router  I’m presented with a password prompt.
    I  enter my password and get connected. However at this point when I type, for  example, the atdt command I don’t see any output  displayed.
    So I  tried typing command atdt <tel no.> and at the same time ran a debug modem  on a separate session. It was from the separate session I could see the call  been made to the remote device and connected successfully. However almost  immediately the modem debug displays message 0236596: Dec  7 2010  12:18:18.236 GMT: TTY69: cleanup pending. Delaying DTR. At no point do I see  output displayed on the session where I connected to the  modem.
    When using telnet to  connect, i.e using the same modem and the same remote device, we have had no  problems it is just with SSH.
    Any suggestion on this will be highly appriciated.
    Thanks
    Alex.

    Philip,
    I first thank you for coming forward to help me on this.
    I use the 30DM(Digital Modem) Card on the router. I have configured on of this modem  on the PRI card(1/18) to make outbound calls. We use this dailup to cyclades the devices located on our remote office. Hence we loose the main internet connectivity we use this option as a backup.
    Show ver:Cisco IOS Software, 3700 Software (C3725-ADVSECURITYK9-M), Version 12.3(11)T5
    ine con 0
    transport output none
    line 72 92
    modem InOut
    modem autoconfigure type mica
    transport input all
    transport output all
    autoselect during-login
    autoselect ppp
    line 93
    absolute-timeout 60
    modem InOut
    modem autoconfigure type mica
    rotary 1
    no exec
    transport input ssh
    transport output none
    line aux 0
    no exec
    transport output none
    line vty 0 4
    logging synchronous
    transport input ssh
    transport output ssh
    Please let me know is this a bug or anything else. AS the same setup works fine when I use TElnet rather than ssh.
    Thanks in advance.
    REgards
    Alex.

  • Scripting reboot for Cisco 300 Series switches

    I would like to have some help putting together a script for rebooting our 300 series POE switches. I have about 150 at this stage to administer and it would make it much easier not to have to remotely reboot them. The IP settings will be the same for each location and we have about 2-5 in each location. I will be logging in through logmein to each remote server, and will run the scripts from this to the local switches. Any help would be appreciated.

    I was playing with my Indigo on an SG-500 and it seems to work.  Create a session for each switch and in the session properties for each switch enter your crendentials (user/pass) IP/port, etc, I was using telnet, port 23 for this and then under the send command tab, on connection I entered:
    reload
    y
    One command per line up to 20 commands I believe and it connected, I saw my prompts and replies and then shutting down.
    So if you try this you can just go down the file tree list for switches with cameras than need a reboot and restart the entire switch if you like, quick and easy.
    You could also add a folder for each switch and a session in that folder possibly for each camera/port with online port number changing for each camera in the session properties and then selectively cycle power for just the affected cameras.
    Example for port 22/camera xxxx:
    conf t
    int gi22 
    power inline never
    power inline auto
    It would take a fair amount of time to set up but once done you could just pick a switch folder and the port in that switch to cycle.  If you have multiple port on a switch you could use
    conf t
    int range gi22-24
    or 
    int range gi1,6,16,20
    power inline never
    power inline auto
    might have to verify that syntax

  • Rack / Cabinet for Cisco 6513/6509 switches

    Hi
    I'm currently engaged in a IT definition project and I have to define 4 racks or cabinets (42U) for 2 core switches (6509E) and 2 datacenter switches (6513). Another network equipments will be deployed in these racks (firewalls, VPN concentrators, stackable switches, etc). The racks will be located on the enterprise datacenter and the chassis switches have all slots filled. The datacenter cooling is under the racks.
    In this scenario, which kind of rack or cabinet is recommended? What is accepted? (open racks, closed cabinets, forced ventilation, etc). Who are the main manufacturers?
    Thanks in advance
    Wesley

    Hi,
    The most important thing in general the rack or cabinet width, i think you have to choose either 75 or 80 cm width, this is very important for the cable management for the patch cord cables from the network modules "RJ45".
    Another important issue, is the cooling for the 6500 switches, since these Cisco switches have a special case, the fresh air enter the chassis from the right and the bad air exit the chassis from the left. So, take care for this case.
    We are using APC brand for the racks and also we choosed special cooling device from APC for the 6500 cooling.
    http://www.apcc.com/
    And also i think the great lakes cabinets are good.
    Please rate helpful posts!
    Thanks
    Abd Alqader

  • Etherchannel issue between 3750 stack and WS-CBS3012 for IBM blade centre

    Hi,
    We are trying to configure Etherchannel between four ports of cisco 3750 stack(2ports from one switch of stack and two ports from another switch of same stack). We are facing issues with this setup. The ports in WS-CBS3012 are going to err disable mode.
    Is  there any limitations associated with such a cross-stack etherchannel configuration. Please suggest if there is any particular sequence of configuration involved.
    Switch1 in stack
    int gi 3/0/3
    switchport mo trunk
    switchport trunk allowed vlan 10-30
    sw tr en dot1q
    channel-group 1 mode on
    spanning-tree guard root
    switch 2 in stack
    int gi 3/0/3
    switchport mode trunk
    switchport trunk allowed vlan 10-30
    sw tr en dot1q
    channel-group 1 mode on
    spanning-tree guard root
    int port-channel 1
    switchport mode trunk
    switchport trunk allowed vlan 10-30
    sw tr en dot1q
    channel-group 1 mode on
    spanning-tree guard root
    in WS-CBS3012 ports are configured with trunk,allowed vlan and etherchannel configuration with mode on.
    With Regards,
    Madhan kumar G

    Hi,
    The commnad "no spanning-tree etherchannel guard misconfig" on WS-CBS3012 resolved the issue.
    Regards,
    Madhan kumar G

  • Using 37xx stack switch can I send snmp messages as syslog ?

    In my environment, we are having cisco 37xx stack switches, I want to know is it possible to use the switch config to send snmp traps as syslog messages to the Syslog-server.
    In our case, we are using siem which has the ability to process syslog messages from different networking switches. What specific event I'm after is related to bandwidth utilization of the interface. It would have been great if there was existing syslog-event for exceeded bandwidth or increase in bandwidth beyond certain bps rate. The only place such information can be obtained is from snmp, but the siem station doesn't understand snmp, So I hope there are some setting which allows the conversion of snmp traps to syslog msg to be forwarded to destination.
    Thanks.

    The iPad cannot use your Android phone number at all so it will not in any way be associated with the device or your Apple ID. You will be using your Apple ID email address as your connect address to use Messages. If you want to look at it this way, your iPad/iMessages will be associated with your Apple account/Apple ID, not with the Android phone number.
    Where some users get into problems is if they go from an iPhone number to an Android phone number. That is not what you are doing.

  • Unable to hard code the ports of cisco 3750x series switch

    hello,
    I have tried with hardcode to 1000 7 Full on the ports which are connected to another switch.
    After changing the port to auto from one side of the switch port came up. Is there any solution to make port up when both sides are hard coded to 1000 & full duplex.
    Simple Words:
    Switch 1 --> Switch 2 --> Hard coded to 1000 & Full --> Down.
    Switch 1 --> Switch 2 --> Auto on one end to Switch 1  --> Up.
    Switch model:
    Switch 1 Cisco 3750x (Gi Switch)
    Switch 2 Cisco 3750 (Gi Switch)
    Regards,
    Ezra.

    Disclaimer
    The  Author of this posting offers the information contained within this  posting without consideration and with the reader's understanding that  there's no implied or expressed suitability or fitness for any purpose.  Information provided is for informational purposes only and should not  be construed as rendering professional advice of any kind. Usage of this  posting's information is solely at reader's own risk.
    Liability Disclaimer
    In  no event shall Author be liable for any damages whatsoever (including,  without limitation, damages for loss of use, data or profit) arising out  of the use or inability to use the posting's information even if Author  has been advised of the possibility of such damage.
    Posting
    Yes, it's possible without a straight through cable, enable auto/auto both sides.    Otherwise you'll need a cross-over cable.
    BTW, if your standard is hard coding copper gig ports, for speed and duplex, you might consider bringing your standard up to date.  Copper gig standard went much further in how auto/auto is supposed to work.  By disabling auto/auto, I believe, you're also disabling some error monitoring too.  Generally, all the major players, e.g. Cisco, would recommend auto/auto for copper gig Ethernet.

Maybe you are looking for

  • How to get values and not index in case of SOC?

    I have created a SOC and i need the values in the bean on valuechange event which are present in the dropdown(i.e 20,50,100). But in this case instead of value me getting the index value(i.e 0,1,2) How can i get the values and not the index value. Qu

  • Captivate 5 and preloader: Error #1065: Variable CPPreloader is not defined.

    Hi, If I add a preloader swf (any of those which ship with Captivate 5 - in \Gallery\Preloaders\AS3) - then when I publish the movie - the flash player throws an error: ReferenceError: Error #1065: Variable CPPreloader is not defined. Then (mostly) c

  • Sync two blackberrys to one outlook calander

    My wife and I bought our first Blackberry's on Saturday to replace our aging phones and Palm PDAs.  So far we have been very impressed with the new phones. I have been successful in setting up both blackberrys to sync a single outlook calander.  Howe

  • Win Explore has screwy FTP drive actions!

    Win 7 Home [Ver. 6.1 Build 7601: Service Pack 1]...Big powerful PC...web-domains =www.here-ugo.com and mavpca.org...running Win Explorer. I can create "FTP Drives" that appear in the left pane of WE. Some times they work. Work = drag & drop to drive

  • Footage goes from progressive to 1080i when dropped in timeline?

    Hi there, Please help! When I drop my 25p pro res progressive footage into FCP timeline the sequence settings switch to 1080i?? This means that i'm having to de-interlace in compresor which looses quality? Is this correct? Footage from AVCHD to pro r