..Primavera\Project Management\PM.ini cannot be set to read-write status

I have installed Primavera P6.1 in a laptop under Administrator Login.
After that, when I log in to the laptop with my user Id, primavera fails to start and gives the following message:
C:\Program Files\Primavera\Project Management\PM.ini cannot be set to read-write status.
Kindly let me know how to fix this problem.
Regards

Please tell your IT Admin to fix as following:
The following is a summary of the minimum system requirements Primavera 6.2.X requires for users to be able to access and run components of the
software :
Window Folders:
 C:\Windows\System32\
dbexpsda30.dll
dbexpint.dll
dbexpoda30.dll
DbExpPrC.dll
dbexpsda.dll
Read&Execute/Read permission for Borland DBExpress drivers
 C:\Program Files\Common Files\Borland Shared\DBExpress\DBXConnections.ini
C:\Program Files\Common Files\Borland Shared\DBExpress\DBXDrivers.ini
Read&Execute/Read/Write permissions to create and modify database alias connections
 C:\Program Files\Primavera
Read&Execute\Read permission to access files needed to run applications
 C:\Program Files\Primavera\Project Management\pm.ini
C:\Program Files\Primavera\Methodology Management\mm.ini
Read&Execute/Read/Write permission to access the ini file - required to log into the applications
 C:\Program Files\Common Files\Primavera Common
Read&Execute/Read permission to access files needed to run applications
 C:\Program Files\Common Files\Primavera Common\Java\BREBootstrap.xml
Read&Execute/Read/Write permission to change connection parameters for Claim Digger or API
(If user does not have WRITE access the Database Configuration Setup utility (C:\Program Files\Common Files\Primavera
Common\Java\dbconfig.cmd) for claim digger / API DOES connect to the database and read the configurations and will create a new configuration if
entered, but displays error "error writing to bootstrap file" and BREBootstrap.xml file will not be updated with the proper database connection information.
 Output directory for File > Export , Job Services output files and Log output files
Read&Execute/Read/Write to create and write output files
Registry Keys:
 HKEY_LOCAL_MACHINE\Software\Borland
READ
 HKEY_LOCAL_MACHINE\Software\Primavera
READ
Note: For the functions Claimdigger, Update Baselines, and Schedule Comparisons the key is opened in Read/Write/Delete mode.
 HKEY_LOCAL_MACHINE\Software\Primavera\Databases\[MM/PM]\Aliases
NOTE: By default, users have FULL CONTROL to their HKEY_CURRENT_USER\SOFTWARE registry keys
If a user does not have FULL CONTROL permission to these keys, when they create a new alias it will be stored under
HKEY_CURRENT_USER\Software\Primavera\Databases\[MM/PM]\Aliases and will be displayed and available to ONLY the user account on the
workstation that created the alias.
If user does have FULL CONTROL permission to to these keys, when they create a new alias it will be stored
under HKEY_LOCAL_MACHINE\Software\Primavera\Databases\[MM/PM]\Aliases and will be displayed and available to ALL user accounts on the
workstation.
Jawad
Novo Rail, Sydney
P6 Project Controls Co-ordinator and Administrator

Similar Messages

  • Not allowed to move (only copy) files within Shared Folder (yes, permissions are set to Read/Write)

    I have moved my media (Music, Movies, Pictures) to the Users/Shared folder.  As I'm doing some cleanup in these folders, I am trying to move several folders/files at once, all within the same Shared folder.  I have confirmed that the permissions settings under "Get Info" are set to "Read/Write" and I have verified and repaired permissions with Disk Utility.  However, every move I try to do is a copy.  I have tried the Command-Drag method, but I'm still left with the green plus sign indicating a copy.
    On smaller files/folders, this wouldn't matter so much as I would copy, then just delete the original.  But I'm dealing with many, many gigs of music and my HD doesn't have space for holding copies, even if the originals will be deleted.
    Very frustrating to have to spend so much time to figure out what would seem to be a very basic file management feature.
    I've searched and read and searched some more, but I'm stuck.  Thanks to any who can help. 

    Do have file sharing and remote login checked
    When on Betty's computer, Sign into Bob's computer with Bob's username & Bob's Password, instead of Betty's.
    BINGO!!!!  Problem solved.  Many thanks!!!

  • Automotive Diagnostic Command Set & kwp2000 Read/Write Memory By Address

    I used NI Automotive Diagnostic Command Set 1.0 Read/Write EEPEOM By Address of ECU base VW TP2.0  KWP2000 diagnostic protocol . I used NI example ReadWrite Memory.vi but not successful. I know must use below step. 
    Description
    The usual procedure for getting a security access to the ECU is as follows:
    Request a seed from the ECU using RequestSeed.vi with access mode = n.
    From the seed, compute a key for the ECU on the host.
    Send the key to the ECU using SendKey.vi with access mode = n + 1.
    The security access is granted if the ECU validates the key sent. Otherwise, an error is returned.
    Who has used NI Automotive Diagnostic Command Set 1.0 and know VW TP2.0 KWP2000 protocol. Please support some suggest and example VI.
    Thanks

    I modify NI example Read/Write Memory lool at attached files.
    Now I know how to calculate the key and successful.But sometimes ok and sometimes no ok. The best luck is pass three error.
    Attachments:
    pho0.JPG ‏99 KB
    ReadWrite ECU.vi ‏66 KB
    seedaddkey.vi ‏12 KB

  • Does anybody know whether Primavera Project Management software can be used under Mac OSX ?

    I itend to use the Primavera software which we are using under Windows with my Apple Notebook and would like to know whether there is an OS X version existing.

    Did you check with Oracle? http://www.oracle.com/us/products/applications/primavera/overview/index.html

  • Primavera Project Management 5.0 & Windows 7

    I am currently working with a customer who just upgraded their environment to Windows 7 and I'm having issues connecting to the database on their server after installing the Primavera client. I found a could posts on this forum and others, however nothing concrete regarding compatibility with W7. I am able to connect to the database from another computer, and I have everything configured the same way, however the client keeps returning a bad public user or password error. Any assistance would be greatly appreciated.
    -G

    Could you please upload the complete error here. There can be various reasons for failure.
    Try to connect to PMDB from SQL*Plus using PUBUSER. If this does not work then try to check your tnsnames entry.

  • Primavera Project Management

    Has anybody had any luck Thinapp'ing the Primavera P6 client and getting it to work in Windows 7?  I captured it on XP and it works on XP, but not 7.  I also tried capturing it on 7, but it still doesn't work on 7.  If I delete the %SystemSystem%\oleaut32.dll and rebuild it then the client will run on 7 and not crash, but I end up with an error about encryption not being available when trying to establish a connection to the database.  Any ideas?

    I know this is an old thread, but was wondering if anyone has any luck with the Primavera P6 stand-alone installation (client & the Oracle Express DB)? The client sounds like it might be a little easier, but I have having major issues trying to vApp the database portion.
    ZT

  • Error message - this project cannot be opened in read-write mode because a previous checkin for this project is not complete.

    Hi,
    I have read the previous posts about this error message and I have tried all resolutions suggested but to no avail.
    This week 4 Project Managers have reported this error message to me. Each time I have checked the Force Check-In Enterprise Objects, the queue and also the cache. None of the projects can be found anywhere. This is obviously frustrating for them and for
    myself.
    If anyone has any advice on where to find these project and check them in properly, and also how to avoid this happening going forward, I would be greatful.
    Thanks,
    Clair.

    Clair --
    Did you look at the local project Cache on the PC of each of the affected users?  Did you ask the affected users to clean out their Cache and try to open each project directly from the Project Server database, instead of opening it from the Cache?
    There is a possibility that the Cache has gotten corrupted on the PC of each of your affected users.  To resolve possible Cache corruption, ask each of the affected users to do the following:
    1.  Close Microsoft Project 2010.
    2.  Click the Start > All Programs > Accessories > Run.
    3.  In the Run dialog, enter the following command:
         %appdata%\Microsoft\MS Project\14\Cache
    4.  Click the OK button.
    Please let us know if this helps.
    Dale A. Howard [MVP]

  • Internal drive wont let me set to Read & Write

    Ok story here is, I had Mac OS X 10.4.8 running on the stock 30GB Maxtor and had a 80GB Seagate running as storage for a while. I decieded "I have enough space on the 80GB for Mac OS why not use it? I upgraded to a 80B Seagate Barracuda hard drive, so i used disk utility's restore button to swap everything over from the stock 30GB Maxtor drive and after that i wanted to move some of the files to folder's such as the Movies folder Documents folder and so on. But when I move the files to those folder's or anywhere else but the hard drive it wants to copy all the files. I looked at the hard drive's accessibility and the Onwership & permissions is grayed out so I cant even change it. What do I do?

    I looked at the hard drive's accessibility and the Onwership & permissions is grayed out so I cant even change it.
    You shouldn't change the ownership or permission settings on the Mac OS X startup disk; doing so may cause the disk to disappear and the computer to fail to start up properly. An administrator account should be able to move files and folders out of that folder that they are the owner of; to move other items out of the top level of the hard disk, press the Command key while dragging the file, click Authenticate if a dialog box appears, and type your administrator password.
    (21107)

  • Project management module not starting

    Hi
    I am facing problem in running
    primavera project management module.
    I had lock
    my system and then upon opning my login i faced an error
    which are shown below.
    Error:
    "The file C:program files\primavera\project
    management\PM.ini can not be set to read write
    status"
    After clik on OK.<br
    />Following error comes:
    "An application
    event has been intercepted.Please note the event code for
    the reference.<br />Event code: AVAA0-3953-8"<br
    />
    Kindly help me out in
    resolving this situation earliest.
    <br
    />
    Regards,
    Jyotir

    Thanks for your reply
    I resolved that
    issue.
    Your point of view is right,it's
    admin rights issue.
    I lost permission for
    read/write for controlling application in .ini file of
    project management.
    Once again thanks for
    your cooperation and advice.
    <br
    />Regards,
    Jyotir

  • P3 Project Manager Crashing with EBDClient error, when refreshing (F5)

    My company has 3 sql databases for Prima on a server; 2 are approximately 1.5GB, and the third is just over 2GB
    We have 5 client machines (xp sp3 32bit), that use the following setup:
    P3 Project Manager version 5 (no service packs installed, but have tried sp1-3 on my machine with the same error)
    oracle client 9.2 with tnsnames pointing to the sql server with the prima databases
    each machine has 2GB memory with a 3-4GB pagefile
    I do not have issues refreshing the other smaller databases.
    both the client and server do not take a significant hit on resources while refreshing.
    both the server and client are not reporting any errors under event viewer.
    they all receive the following error when refreshing (F5) while logged in the third and largest database:
    Message (Tab)
    Application exception
    type: EDBClient
    Event code: IMFTO-3501-8
    Description: Insufficient memory for this operation
    Context (tab)
    app title: primavera project management
    exe: pm.exe
    object: tmainmenu
    context:
         1. tfrmmain.refreshVDBengine
         2. tfrmmain.actrefreshExecute
         3. tfrmmain.actProjectActivitiesExecute
         4. tfrmmain.actProjectsExecute
         5. tfrmmain.actProjectsActivitiesExecute
         6. tfrmmain.actProjectWBSExecute
         7. tfrmmain.actProjectActivitiesExecute
    Evironment (tab)
    Components
    =============
    ORI: ORI Win32 #
    ORI/DB: PMDB,0500.0024.0001.0002
    IMG: IMG win32 #1000
    SYS INFO
    =============
    username: "user's name" Hostname: "their computer name"
    OS version:     winNT 5.1, build 2600, SP3

    ...\OracleBI\web\catalogmanager\catalogmanager.ini
    -vmargs
    -Xmx1024M
    -Djava.library.path=E:\OracleBI\web\bin
    -Declipse.noRegistryCache=true
    amend---------------------------------------------------------
    -vmargs
    -Xmx512M
    -Djava.library.path=E:\OracleBI\web\bin
    -Declipse.noRegistryCache=true

  • Project Management - Summarize Function

    Hi, All!
    I have been studying the integration process between P6 and EBS Projects and notice that we have to run the Summarize before execute the integration process from P6 to EBS.
    But, I did not conclude why I need to run this summarize because it was not possible to see any results after running this process on the activity or EPS columns. And why I would need to run this summarization out of the integration scope.
    So, Could anyone give any example on using this summarize function? Why is it needed/helpful?
    Menu Option: Tools -> Summarize
    Thanks in advance.

    "EBS Projects" stands for Oracle Enterprise Business Suite, module Projects.
    This Oracle ERP solution that has an integration solution with Primavera Project Management P6.
    Is there anyone who uses the Summarizer in order to keep the ETC and EAC updated and published to the team involved on the project? Besides the interface functionality, would you have any other situation where the summarizer is helpful?

  • System Level freeze When running Project manager...

    LOGIC PRO 7.2.3
    OSX 10.4.8
    G5 quad
    When I Attempt to initialize the preferences, the whole system FREEZES UP.
    This happens when it is attempting to rebuild the "Tree".
    AND...
    If I launch the "Project Manager" it locks up the system when reading the directory tree....
    This is a CLEAN INSTALL of 10.4.8.....
    BLACK SCREEN "You must restart your Computer"...
    Help!!!
    G5 Quad   Mac OS X (10.4.8)  

    Any advice?
    Yes, but you're not going to like it.
    Before I say more, let me tell you that I went through a similar situation when I first got my G5 (which was a dual 2.7). Kernel panics, every problem in the book. (I recently went through a similar episode with my Quad). And so the advice I'm going to offer you may seem absolutely radical. It might even make you mad. But most of what I'll advise was exactly the advice offered to me over a year ago by this forum's members and it got me up and running.
    First, try re-initializing the firmware on your computer. Best thing to do is take it to an Apple store and have them do it. It's a 2-minute process that could potentially cure all of your machine's ills.
    When you're there, ask them to show you how it's done. It's not something to be done on a regular basis and a pretty radical thing to do, but it could knock the sense back into your computer in a pinch.
    If that doesn't solve the problem, you will need to start from scratch. This means wiping your hard drive entirely (down to zeros). Then re-install the software from your factory OS CD and NOT a clone of your existing drive.
    The reason this is necessary is this: there is every possibility that the OS on your system -- as installed by Apple -- is the very thing that's corrupting your computer/making you unable to run Logic. If you want the explanation I'll give it to you, but suffice it to say that the OS on your factory install CD is correct for your computer, whereas the OS installed BY the factory on your computer may not be. This is not BS or voodoo. It's a documented fact (documentation can be found on Apple's very own website).
    Anyway, after you've wiped your drive and installed the OS from the disk, your very next step would be to install ProApps 3.1.
    Then install Logic and do not copy your preferences from an older backup, period.
    Yes, it will be a total PITA to re-establish all of your key commands from scratch, but by doing so you can guarantee that your preferences are absolutely virgin.
    The next step is to update the OS to whatever you want it to be.
    After this, start installing your 3rd party plugs and anything else you want to add to the computer.
    I suggest you follow these steps exactly in this order, as it worked for me, and worked very well.
    Message was edited by: iSchwartz

  • Read/write access on external drive set to none; can't see drive to change

    I was learning about profiles and permissions and set the Read/write access on my external drive to none. I wanted to protect my guests from accidentally viewing private files. I thought I was doing it for that profile only, but now I can't see the drive to change it back. I have already tried using the disk utitility and re mounting the drive, but still cannot see the drive icon on the desktop or anywhere. I know the drive is okay because I can see it in disk utility but disk utility says the read/write access is none.
    thanks for anyone that can advise me. I'm more of a PC expert, than a Mac expert.
    Gary

    Follow the instructions in this FAQ which are relevant to your situation; logging in as root is not needed.
    (18945)

  • Transportable tablespace (metadata export with READ WRITE tablespace set)

    Is it possible to use transportable tablespace backup for import if data files for tablespace set has been copied when tablespaces were READ ONLY but the metadata export (or a part of it) is taken after tablespaces has been set to READ WRITE?

    Actually the size of datafile(s) are too huge so unable to test the same on test box with TTS export backup.
    But my question is if there were no structural changes (DML might be there on tablespace objects) even after making tablespaces to READ WRITE till the time metadata export is completed(data files are copied to staging location already before tablespaces has been set READ WRITE), Shall I use these backup for import?

  • When I go to duplicate a presentation I get the following error:  Unsaved Keynote Document.  Autosave couldn't be moved because you don't have permission to access AutoSave Information?  My permissions are set at read

    When I go to duplicate a presentation I get the following error:  Unsaved Keynote Document.  Autosave couldn't be moved because you don't have permission to access AutoSave Information?  My permissions are set at read & write.

    I noticed that I have three different log in accounts on my computer, much to my surprise. Could that be causing this problem?
    That's unlikely. You would have had to save a document into another user's account and be trying to work on it - directly from their account.
    "“Unsaved Pages Document.pages” couldn’t be moved because you don’t have permission to access “Autosave Information”.
    Have you checked the permissions on your Autosave Information folder? Here are mine.

Maybe you are looking for

  • Mac Book Pro or Mac Book Air

    Hi, I'm new here. I am a student  and i want to buy a Mac for my study. I don't know which Mac is better for me, so i Hope you can help me to find the right Mac.

  • XMII Content

    Hi, I am very new in xMII area and trying to setup the system from the dashboard side. We have installed the xMII system successfully. I wanted to know if there is any preconfigured package / application  ( Like SAP PI/XI - we get content for SCM ) w

  • Adjustment Brushes not working (3.0 & 3.2)

    While processing some images the other night, using the adjustment brushes, burn, 3 large white squares appeared on the image for a few moments (5 seconds or so) before disappearing. Since then, the adjustment brushes have no effect what so ever on m

  • Differences in USER_SNAPSHOTS and USER_MVIEWS

    Hi, We're using Materialized Views to do replication of several remote databases. This with Oracle version 10.2.0 on a windows server. I've noticed following result when checking status of our Materialized Views. In Oracle SQL Developer, a detail of

  • Cannot initialize SecurID client-server communications

    Hi! I've installed RSA/Ace Server on a machine where iPortal is running too. The path to ace server's config files is /opt/ace/data. We've configured SecurID Server Identifier Name as "Server000". We don't really know what this means, so we didn't ch