Prime Infrastructure 2.0 Assurance issue

Hi together,
I have a problem with our Prime Infrastructure 2.0 regarding the assurance features.
The appliance can only handle flows exported from our WLAN controller, but not from any wired device (neither standard netflow nor flexible netflow!).
Flows are received correctly on port 9991 on the PI appliance, I validated that via tcpdump. But the sending devices are not listed on "data sources".
Has anyone experienced the same problems, or even has a solution for the problem explained?
Regards
Sebastian

we need to have Assurance license for NAM to work with PI 2.0.  have you installed that ?
Assurance License: Provides access to the  Assurance feature set, which provides end-to-end network visibility of  application and service performance to help ensure end-user quality of  experience. The Assurance feature set also provides the ability to  manage and aggregate data and views across multiple Cisco Prime Network  Analysis Modules (NAMs). The Assurance license is based on the number of  managed NetFlow-enabled interfaces. Assurance licenses are available in  bundle sizes of 15, 50, 100, 500, 1000, and 5000 NetFlow-enabled  interfaces. The 15 interface license has a restriction that allows you  to manage only up to 5 NAMs, whereas the other Assurance license bundles  do not place a restriction on the number of NAMs that you can manage.  The 15 interface license can only be used standalone and not combined  with the Lifecycle licenses. You need to purchase a 50 interface  Assurance license or larger to use with other Cisco Prime Infrastructure  feature licenses.
Thanks-
Afroz
[Do rate the useful post]

Similar Messages

  • CISCO PRIME INFRASTRUCTURE 1.2 CONFIG ISSUE

    hello all,
    this is my fist time running a cisco prime infrastructure1.2  but it seem not to be working properly as i have errors on it,
    I had issues from the very begining and had to write erase the config but the appliance only boots to a blank screen wit a cursor.
    can anyone advice on how to restore it back to initial setup
    and please whats the effect of the RESET button on the device.
    thanks

    I don't know if this has been fixed in 2.0 or not.  By the looks of the bug it hasn't.  However, there is a workaround-
    https://tools.cisco.com/bugsearch/search?kw=prime%20infrastructure%20copy%20run%20start&pf=prdNm&sb=anfr&srtBy=byRel&bt=custV
    BugID
    CSCuf89957
    Prime Infrastructure - No option to save running config to startup
    Conditions:
    Prime Infrastructure 1.2/1.3
    Workaround:
    Create a Configuration Template that runs either:
    "do write mem"
    Or for devices which no longer support "write mem", use:
    "file prompt quiet
    do copy run start
    no file prompt quiet"

  • PRIME INFRASTRUCTURE 1.2 STARTUP ISSUES

    I have had to do a second restore in 2 months from backup of the entire system, on this occasion NCS is not starting fully,
    Health Monitor Server is starting.
    Reporting Server is Starting
    Ftp Server is running
    Database server is running
    Tftp Server is running
    Matlab Server is running
    NMS Server is stopped.
    SAM Daemon is running ...
    DA Daemon is running ...
    Syslog Daemon is running ...
    This is getting very frustrating, has anyone experienced this issue?
    I did an ncs db reinitdb, restored the system from a recent backup......

    I have had that issue in my lab, but really don't know why. It might be due to the resources that was allocated to my VM and maybe changing it and then rebooting the server which then I could never get to startup again. I have just learned to take a snapshot and revert back to a good snapshot if I run into the issue again.
    Sent from Cisco Technical Support iPhone App

  • Cisco Prime Infrastructure 1.3 - Assurance reporting

    We have Assurance license and we are exporting netflow and pretty much everything is working fine. Traffic is seen, recognized by protocol, DSCP, source/destination IPs, etc.
    Now, the question is, can dashlet present data that is less than one hour?
    For example, you select Serial interface on MPLS router and it will show you IP addresses that used most amount of bandwidth in last hour, but it would be much better if we could chose much less amount of time (like 5 minutes or lower), because in case of temporary congestion it won’t give exact information who is using most of the traffic. We would like to see who is currently consuming most of the bandwitdth.
    Or is there any other way to get info for interface level (or device) who’s using most and what type of traffic (something similar to show ip cache flow command on the router).

    Under the "Detailed Dashboards" pages, you can customise the Time Frame in there.  Default is past hour but you can specify smaller and/or more specific time periods as necessary... I've checked that this works ok in CPI 1.3 for both the "Interface" and the "End User Experience" tabs.
    Richard

  • Prime Infrastructure Demo License

    If I apply the Demo license to a licensed Prime Infrastructure server will it enable all the features so I can test the Netflow features for the demo period?  I have never used the Netflow features and would like to test drive for a little and decide if we want to move of our current platform.
    Thank you all.

    You purchase licenses to access the Prime Infrastructure features required to manage your network. Each license also controls the number of devices you can manage using those features.
    You need a base license and the corresponding feature licenses (such as Assurance or Data Center licenses) to get full access to the respective Prime Infrastructure features to manage a set number of devices.
    If you have installed Prime Infrastructure for the first time you may access the lifecycle and assurance features using the built-in evaluation license that is available by default. The default evaluation license is valid for 60 days for 100 devices. You can send a request to [email protected] if:
    You need to extend the evaluation period
    You need to increase the device count
    You already have a particular feature license and need to evaluate the other feature licenses
    To troubleshoot licenses, you will need to get details about the licenses that are installed on your system. Click Help > About Prime Infrastructure to access your license information.When troubleshooting licenses, it is important to remember that Prime Infrastructure has five types of licenses:
    Base: Required for every Prime Infrastructure installation. The requirement stems primarily from the need to do accurate royalty accounting by knowing how many Prime Infrastructure instances have been purchased. A Base license is required for each instance of Prime Infrastructure, and is a prerequisite for all other license types.
    Lifecycle: Regulates the total number of devices under Prime Infrastructure management.
    Assurance: Regulates the total number of NetFlow devices under Prime Infrastructure management.
    Collector: Regulates the total number of NetFlow data flows per second that Prime Infrastructure can process.
    Data Center: Regulates the total number of data-center devices under Prime Infrastructure management.This license type was introduced in Prime Infrastructure version 2.2.
    All five types of licenses are supplied as either evaluation or permanent licenses:
    Evaluation: These licenses permit or extend access to Prime Infrastructure for a pre-set period. You can apply only one evaluation license of each type (that is, only one Lifecycle evaluation license, one Assurance evaluation license, and so on). You cannot apply an evaluation license over a permanent form of the same license.
    Permanent License: These permit access to Prime Infrastructure features as specified and are not time-limited. Permanent licenses can be applied over evaluation licenses, and can also be applied incrementally (that is, you can have multiple permanent Assurance licenses, and so on).
    http://www.cisco.com/c/en/us/td/docs/net_mgmt/prime/infrastructure/2-2/administrator/guide/PIAdminBook/licensing.html#pgfId-1055426

  • Prime Infrastructure 2.1 Client Statistic Report Issues

    Hello Community,
    I hope you can help with a couple of issues I am seeing on Prime Infrastructure 2.1, running an evaluation 60 day license.
    My PI 2.1 build is currently managing a WLC 5508 running 7.4.121.0, which has been added successfully. No configuration changes were applied to the WLCs, other than SNMP community. No AVC or medianet configuration is applied.
    When looking in the 'Operate>Client and Users' dashboard; I can see connected clients and if I select one of them, I can see further details like session, security and client statistics (showing traffic and 802.11 metrics). These are the table views that show current values, however, further down I see graphs but they do not contain any information for RSSI, SNR or traffic sent & received (packets or bytes).
    Question: Should I see this information under an evaluation license and if so, what could be stopping it?
    Also, when I run the reports 'Report>Report Launch Pad' and select 'Client>Client Traffic' or 'Client>Client Throughput' the resulting report contains 0 bps, when I select 'Report By' AP by Floor Area. I have created a single floor area and placed three access points into it.
    Out of interest if I do a report of the same type using 'Report By' All or AP by Controller, I do see traffic graphs for 3 out of 333 access points. Just not the access points that are in my floor area. Also the amount of traffic utilization is tiny (less than a kbps) for a WLC with 800 users.
    For a 'Client>Client Count' report using AP by Floor Area, I do see the client numbers connected to the WLC/APs in my configured floor area.
    Question: Should I see reports for client traffic and throughput under an evaluation license for floor areas and if so, what could be stopping it?
    I have checked the background task and the 'Client Statistics' task is enabled and run time is being updated.
    Kind regards,
    Ian

    Hi,
    here is an update:
    There are more than one Report you need to start to get data for Device, FAN, Power Supply, Module - look at these reports:
    Report > Report Launch Pad > Device > Inventory
    Report > Report Lauch Pad > Device > Wired Detailed Device Inventory
    Report > Report Lauch Pad > Device > Wired Module Detail > Wired Module Detail Report Details
    SFPs and GBICs cannot be reported til now - there are working on it.
    br,
    chris

  • Prime Infrastructure 2.1 - Fan-Failure SNMP-Trap Issue

    Hello,
    I am facing the following Prime Infrastructure (v2.1) issue:
    - A Fan-Failure SNMP-Trap from a Cisco 3650 switch doesn't appear on Prime, but a Link-Failure from the same switch does.
    - The both events appears on Prime with Syslog.
    - The command "snmp-server enable traps envmon fan shutdown supply temperature status" is set up.
    - The switch is in "Managed" state in PI, I have checked the ACL at the "snmp-server community" command, it is okay.
    - I have set up an SNMP-Trace for the switch on PI, but only "SNMP Null was returned for class com.cisco.server.managedobjects.bridge.Fan3KStats attribute fanIndex" arrived. Please find the log below.
    07/02/14 12:39:53.211 TRACE [presence-9] [] Adding attributes for object Fan3KStats[151206060_,1012]
    07/02/14 12:39:53.211 TRACE [presence-9] [] Index name : fanIndex
    07/02/14 12:39:53.211 TRACE [presence-9] [] Index Value : 1012
    07/02/14 12:39:53.211 TRACE [presence-9] [] Device MIB table index: .1012
    07/02/14 12:39:53.211 TRACE [presence-9] [] MIB table row index: .1012
    07/02/14 12:39:53.211 TRACE [presence-9] []     OID for : fanIndex = 1.3.6.1.2.1.47.1.1.1.1.1.1012
    07/02/14 12:39:53.211 TRACE [presence-9] []     OID for : fanOperStatus = 1.3.6.1.4.1.9.9.13.1.4.1.3.1012
    07/02/14 12:39:53.211 TRACE [presence-9] [] Get fragment
    07/02/14 12:39:53.211 TRACE [presence-9] [] Creating PDU: Get
    07/02/14 12:39:53.211 TRACE [presence-9] []     VarBind OID=1.3.6.1.2.1.47.1.1.1.1.1.1010
    07/02/14 12:39:53.211 TRACE [presence-9] []     VarBind OID=1.3.6.1.4.1.9.9.13.1.4.1.3.1010
    07/02/14 12:39:53.211 TRACE [presence-9] []     VarBind OID=1.3.6.1.2.1.47.1.1.1.1.1.1011
    07/02/14 12:39:53.211 TRACE [presence-9] []     VarBind OID=1.3.6.1.4.1.9.9.13.1.4.1.3.1011
    07/02/14 12:39:53.211 TRACE [presence-9] []     VarBind OID=1.3.6.1.2.1.47.1.1.1.1.1.1012
    07/02/14 12:39:53.211 TRACE [presence-9] []     VarBind OID=1.3.6.1.4.1.9.9.13.1.4.1.3.1012
    07/02/14 12:39:53.218 TRACE [presence-9] [] Error Status: 0
    07/02/14 12:39:53.218 TRACE [presence-9] [] Error index:  0
    07/02/14 12:39:53.218 TRACE [presence-9] [] SNMP Null was returned for class com.cisco.server.managedobjects.bridge.Fan3KStats attribute fanIndex
    07/02/14 12:39:53.218 TRACE [presence-9] []     Setting attribute: fanOperStatus
    07/02/14 12:39:53.218 TRACE [presence-9] []     SnmpInt Value : ?
    07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes, storing result, class=com.cisco.server.managedobjects.bridge.Fan3KStats, attr=fanOperStatus
    07/02/14 12:39:53.218 TRACE [presence-9] [] SNMP Null was returned for class com.cisco.server.managedobjects.bridge.Fan3KStats attribute fanIndex
    07/02/14 12:39:53.218 TRACE [presence-9] []     Setting attribute: fanOperStatus
    07/02/14 12:39:53.218 TRACE [presence-9] []     SnmpInt Value : ?
    07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes, storing result, class=com.cisco.server.managedobjects.bridge.Fan3KStats, attr=fanOperStatus
    07/02/14 12:39:53.218 TRACE [presence-9] [] SNMP Null was returned for class com.cisco.server.managedobjects.bridge.Fan3KStats attribute fanIndex
    07/02/14 12:39:53.218 TRACE [presence-9] []     Setting attribute: fanOperStatus
    07/02/14 12:39:53.218 TRACE [presence-9] []     SnmpInt Value : ?
    07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes, storing result, class=com.cisco.server.managedobjects.bridge.Fan3KStats, attr=fanOperStatus
    07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes, assembling attributes
    07/02/14 12:39:53.218 TRACE [presence-9] []     MIB lookup, OID for: powerSupplyIndex = 1.3.6.1.2.1.47.1.1.1.1.1
    07/02/14 12:39:53.218 TRACE [presence-9] []     GetMultiAttributes needs class=com.cisco.server.managedobjects.bridge.PowerSupply3kStats, field=powerSupplyIndex
    07/02/14 12:39:53.218 TRACE [presence-9] []     MIB lookup, OID for: powerSupplyOperStatus = 1.3.6.1.4.1.9.9.13.1.5.1.3
    07/02/14 12:39:53.218 TRACE [presence-9] []     GetMultiAttributes needs class=com.cisco.server.managedobjects.bridge.PowerSupply3kStats, field=powerSupplyOperStatus
    07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes invoked
    07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes building OIDs for next PDU
    07/02/14 12:39:53.218 TRACE [presence-9] [] Adding attributes for object PowerSupply3kStats[151206060_,1009]
    - The switch sends the SNMP Trap, based on the followings:
    Jul  7 13:38:30 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    Jul  7 13:38:30 UTC: %PLATFORM_THERMAL-6-FRU_FAN_OIR: Switch 1: System fan 1 removed
    Jul  7 13:38:30 UTC: %PLATFORM_THERMAL-1-FRU_FAN_NOT_PRESENT: Switch 1: System fan 1 not present
    Jul  7 13:38:30 UTC: SNMP: Queuing packet to IP_ADDRESS
    Jul  7 13:38:30 UTC: SNMP: V2 Trap, reqid 33202, errstat 0, erridx 0
    sysUpTime.0 = 576753333
    snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
    ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, NotExist
    ciscoEnvMonFanStatusEntry.3.1010 = 5
    Jul  7 13:38:30 UTC: SNMP: Queuing packet to IP_ADDRESS
    Jul  7 13:38:30 UTC: SNMP: V2 Trap, reqid 33203, errstat 0, erridx 0
    sysUpTime.0 = 576753333
    snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
    ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, NotExist
    ciscoEnvMonFanStatusEntry.3.1010 = 5
    Jul  7 13:38:30 UTC: SNMP: Queuing packet to IP_ADDRESS
    Jul  7 13:38:30 UTC: SNMP: V2 Trap, reqid 33204, errstat 0, erridx 0
    sysUpTime.0 = 576753333
    snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
    ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, NotExist
    ciscoEnvMonFanStatusEntry.3.1010 = 5
    Jul  7 13:38:30 UTC: SNMP: Queuing packet to IP_ADDRESS
    Jul  7 13:38:30 UTC: SNMP: V2 Trap, reqid 33205, errstat 0, erridx 0
    sysUpTime.0 = 576753333
    snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
    ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, NotExist
    ciscoEnvMonFanStatusEntry.3.1010 = 5
    Jul  7 13:38:31 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    Jul  7 13:38:31 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    Jul  7 13:38:31 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    Jul  7 13:38:31 UTC: SNMP: Packet sent via UDP to IP_ADDRESS 
    Jul  7 13:38:45 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    Jul  7 13:38:51 UTC: %PLATFORM_THERMAL-6-FRU_FAN_OIR: Switch 1: System fan 1 inserted
    Jul  7 13:38:54 UTC: SNMP: Queuing packet to IP_ADDRESS
    Jul  7 13:38:54 UTC: SNMP: V2 Trap, reqid 33206, errstat 0, erridx 0
    sysUpTime.0 = 576755733
    snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
    ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, Normal
    ciscoEnvMonFanStatusEntry.3.1010 = 1
    Jul  7 13:38:54 UTC: SNMP: Queuing packet to IP_ADDRESS
    Jul  7 13:38:54 UTC: SNMP: V2 Trap, reqid 33207, errstat 0, erridx 0
    sysUpTime.0 = 576755733
    snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
    ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, Normal
    ciscoEnvMonFanStatusEntry.3.1010 = 1
    Jul  7 13:38:54 UTC: SNMP: Queuing packet to IP_ADDRESS
    Jul  7 13:38:54 UTC: SNMP: V2 Trap, reqid 33208, errstat 0, erridx 0
    sysUpTime.0 = 576755733
    snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
    ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, Normal
    ciscoEnvMonFanStatusEntry.3.1010 = 1
    Jul  7 13:38:54 UTC: SNMP: Queuing packet to IP_ADDRESS
    Jul  7 13:38:54 UTC: SNMP: V2 Trap, reqid 33209, errstat 0, erridx 0
    sysUpTime.0 = 576755733
    snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
    ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, Normal
    ciscoEnvMonFanStatusEntry.3.1010 = 1
    Jul  7 13:38:55 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    Jul  7 13:38:55 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    Jul  7 13:38:55 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    Jul  7 13:38:55 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
    It seems like PI and the switch doesn't understand each other concerning the fan...
    Thanks for any ideas, comments and feedbacks,
    Csaba

    I have the very same problem.
    The switch has a power supply error (one of the two is down). There is the syslog message in PI about it, but no event has created, so nor alarm is there as well.
    When I check the status of the switch in the Device Work Center, and choose the Environment in Device Details I can see that PI has not realized the power supply error.
    However when I click on the Sync for this very device the power supply status is updated, but still no event or alarm.
    This is the case with the FANs as well.

  • Cisco Prime Infrastructure patch 2.1.1 - HA issue

    Hello,
    I have a problem with the Cisco Prime Infrastructure patched to version 2.1.1. I did exactly what Installation Guidelines say:
    http://www.cisco.com/c/en/us/td/docs/net_mgmt/prime/infrastructure/2-1-1/release/notes/cpi_rn.html
    – Install the Prime Infrastructure 2.1.1 patch by using the Administration > Software Updates page on the primary server.
    – Restart the primary server.
    – Verify that the patch installation is complete. If you find the installation complete, decommission and reinstall the secondary server and add it back to the primary server.
    I reinstalled HA server and I'm trying to add it to HA but I get "Failed to authenticate - Primary(xx.xx.xx.xx) and Secondary(xx.xx.xx.xy) PI version does not match"
    Can you help me with that? What I'm doing wrong? or maybe this patch is not prepared to work in HA mode?
    Regards

    Symptom:
    The installation instructions of PI 2.1.1 patch in a High Availability environment are not accurate and following these steps will result in the inability to re-pair the Primary and Secondary servers.
    Conditions:
    If the instructions are followed, then when the user attempts to re-pair the servers, an error will be encountered:
    "High Availability Registration Failed - Failed to authenticate - Primary (x.x.x.1) and Secondary (x.x.x.2) PI version does not match".
    Instead, the following steps have proved to work correctly:
    1. Upload and install patch on primary.
    2. Upload and install patch on secondary.
    3. Stop NCS services on secondary
    4. Stop NCS services on primary
    5. Start services on secondary
    6. Start services on primary
    7. Re-pair HA servers from primary
    Workaround:
    Workaround 1:
    On the secondary, go under root and issue:
    # cd /opt/CSCOlumos/bin/
    # ./hamode.sh primary
    Answer 'yes' when prompted.
    Go to admin user and execute
    # ncs stop
    After the services are stopped:
    # ncs start
    When the services are back up, login to the secondary GUI as you would login to a primary server
    Go under Administration > Software update, upload the patch and install it.
    Go to admin user and execute
    # ncs stop
    After the services are stopped:
    # ncs start
    When the services are up, go under root and issue:
    # cd /opt/CSCOlumos/bin/
    # ./hamode.sh secondary
    Answer 'yes' when prompted.
    Go to admin user and execute
    # ncs stop
    After the services are stopped:
    # ncs start
    After the message that services started successfully on the secondary, initiate a new High Availability configuration from the primary. Now the synchronization between the two servers should succeed.
    Workaround 2:
    Redeploy or reinstall the Primary server, restore the backup which was taken prior to applying the patch, reconfigure the High Availability and continue with the steps described in the Conditions section.
    Further Problem Description:
    Release Notes have been updated with more precise instructions.
    Known Affected Releases:
    (1)
    2.1(0.0.85)

  • Cisco Prime Infrastructure 1.2 and Aironet 1250 + VSS issues

    Hi,
    I  am new to the NCS implementations and configurations. I have one very  specific case with Cisco Prime Infrastructure 1.2 and autonomnous APs  and several issues with Cisco VSS on 6500 switches.
    So here is the version from Prime:
    NCS/admin# show version
    Cisco Application Deployment Engine OS Release: 2.0
    ADE-OS Build Version: 2.0.1.038
    ADE-OS System Architecture: x86_64
    Copyright (c) 2005-2010 by Cisco Systems, Inc.
    All rights reserved.
    Hostname: NCS
    Version information of installed applications
    Cisco Prime Network Control System
    Version : 1.2.1.012
    IOS version on our APs (which are autonomnous) is:
    AP-N-1>show ver
    Cisco IOS Software, C1250 Software (C1250-K9W7-M), Version 12.4(25d)JA1, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2011 by Cisco Systems, Inc.
    Compiled Thu 11-Aug-11 03:23 by prod_rel_team
    Well  the issue what we have now is that access point has been added but its  not recognized by the NCS prime. I have tried all three versions of SNMP  but I get the same result. The SNMP configuration is valid since I use  the same for my switching infrastructure. When I enter "debug snmp packets" and "terminal monitor" I can see the SNMP communication between Prime and Aironet 1250 which is standalone.
    When  I switch to Lifecycle theme and go to Operate > Device Monitor  Center I see all devices I have added. The Aironet 1250 is reachable but  under collection status I get Managed with Warnings. When I hover over  with my mouse I get "None available".
    I  have successfully added my switching infrastructure in total, which is  operating perfectly for Catalyst 2960/3650/3750/4500 series but for 6500  under VSS I have some warnings. The device is recognized by the system  which is excellent and all is operational. I get the following errors  under Collection Status:
    feature_sensor
    SNMP request timed out
    feature_powerSupplyFanStatus-6k
    SNMP request timed out
    IdentityCapability
    The device is unreachable.
    feature_flashdevice
    SNMP request timed out
    sam_ipsla_feature
    The device is unreachable.
    What can be done to resolve these issues ? I have attached a screenshot of this particular issue. The affected access point is 172.16.165.241.
    Predrag Petrovic       

    Hi rajeeshp,
    Currently I am not allowed to upgrade it because of internal procedures involved in upgrading a specific piece of software (obtaining permissions from various departments). Is it free to upgrade from 1.2 to 1.3 or there is a specific charge for that.
    Predrag Petrovic

  • Cisco Prime Infrastructure MESH LINK ISSUE

    Hi,
    a Customer of us has a trouble with cisco Prime Infrastructure 1.2.0.12 and AP mesh link.
    There is an huge database ( i suppose the issue can be here ) and when we display some map ( each floor has about 6 RAP and 24 MAP ) we cannot see the MESH information and link draw.
    The only way to dipley them is to disable "refresh from network": this way I'm able to show these link..... until a click before.
    What i noticied when all was working fine, after i click to some floor:
    1) the software started to show the map with normal color and no mesh info displayed ( just ap and coverage cloud )
    2) after few time ( less than 1 second ) the map was becoming a little bit lighter and the mesh info was merged to the map
    We are missini the second step
    Anyone had the same issue ?
    best regards
    Luigi
    PS: I opened a case with WCS version 6.0 ( same issue ) but, after some months, no risult. The last version working fine was WCS 5.2

    Just to add some more informations:
    - disabling "refreshj from network" ( building properties ) the link and mesh info are showed
    - while I'm on a floor, after some refresh, i loose the mesh link draw and, if i click on an AP, i loose also mesh info in the popup. It' s like, after some refresh, the AP are no more recognized as Mesh ( !?!? )
    regards
    Luigi

  • Cisco prime infrastructure 1.1 issue

    hi:
    i purchase a R-PI-1.1-K9 with  R-PI-1.1-100-K9,but now i find the cisco website can't download Prime infrastructure 1.1 anywhare,only 1.2 and above version exist.but the device base licences(R-PI-1.1-100-K9) is  based RI version 1.1.how do we resolve this issue.somebody tell me that R-PI-1.1-100-K9 can use in prime infrastructure 1.2 ,anyone can help me and tell me how to use it and give me the step by step guide,thanks very well.
    jerry

    A 1.1 license file should work with PI 1.2. See the note at the bottom of Table 3 here.
    Hopefully your product was ordered with Software ApplicationSupport with Upgrade (SASU) option. That will further entitle you to upgrade to PI 1.3 and, soon, to PI 2.0. Each release ins incrementally more functional and many bug fixes are incorporated.

  • Assurance feature set license on Prime Infrastructure 1.2

    Hi,
    I have installed Cisco Prime Infrastructure 1.2 separately from LMS4.2. LMS4.2 is in production. I just want to run PI1.2 in parallel with LMS4.2 before migrating to PI1.2. Currently I have LifeCycle permanent license. Why don't I have the assurance lfeature set license. it is running in evaluation mode. please look below:

    Assurance is a separate license for PI 1.2. Unless and until you install an assurance license you will see that message.
    The appropriate part number would be L-PI12-AS-xx where "xx" is the number of licensed devices (15, 50, 100, 500, 1k, and 5k are the options).
    More information can be found in the Ordering and Licensing Guide.

  • Cisco Prime Infrastructure - Assurance. Upgrade from 1.2 to 2.0

    Hi,
    We had purchased Prime Infrastructure 1.2 with SAU smartnet. Before we deployed 1.2 now I see 2.0 version is out and we qualify for upgrade license. However when I login to CCO to download the OVA file, I see 3 different editions. Express, Pro and Standard. Which one do I qualify to install? I have purchased following part numbers with 1.2 version.
    R-PI12-K9     -     Qty 1
    L-PI12-LF-100-LIC     -     Qty 1
    L-PILMS42-100     -     Qty 1
    L-PI12-LF-100     -     Qty 1
    Thanks in advance,
    Sam

    Hi,
    Check the below link for difference between [ Express, Pro and Standard ]
    http://www.cisco.com/en/US/docs/net_mgmt/prime/infrastructure/2.0/quickstart/guide/cpi_qsg.html#wp46865
    http://www.cisco.com/en/US/docs/net_mgmt/prime/infrastructure/2.0/quickstart/guide/cpi_qsg.html#wp75315
    L-PI12-LF-100-LIC and
    L-PI12-LF-100   :: Prime Infrastructure 1.2 - Lifecycle - 100 Device Lic PAK
    are same as per my understanding and you can use these license to installed PI 2.0 with device count of 100.
    Note: you  can also add additional licenses(feature license ) for more Lifecycle (via R-PI12-K9 skus), which can be used for both Prime Infrastructure and LMS.
    Thanks-
    Afroz
    [Do rate the post if you find it useful]

  • Cisco Prime infrastructure 1.2.1.012 -- HA issue

    Hi All
    I will explain the background before, our customer using Cisco Prime Infrastructure 1.2.1.012 and do HA. However I got error message wcss1 (in attaced file) from HA configuration. (First I had done HA configuration before and it worked. But I get error message wcss1 after i tested failover on cisco prime). I found bug case CSCud12229 that is same error message. But i still confuse with work around "Workaround:Change the database mode to Read-Write by executing query ?alter database open? or execute the shell script - /opt/CSCOlumos/bin/recover_HADeadLock.sh" anyone understand please help.
    And another option I tried to upgrade with version 1.3 also but it have a bug no CSCud80157. It is the problem with HA registration fial so, i would like to ask you all that if i need to do HA on Cisco Prime infrastructure which version i should to install ? coz  I saw 1.2 or 1.3 also have a bug with HA
    Thanks
    V

    Hi rajeeshp,
    Currently I am not allowed to upgrade it because of internal procedures involved in upgrading a specific piece of software (obtaining permissions from various departments). Is it free to upgrade from 1.2 to 1.3 or there is a specific charge for that.
    Predrag Petrovic

  • Prime Infrastructure issues with collection, dscp, mos, etc

    We have a virtual Prime Infrastructure appliance installed.  It currently shows collection status managed with warnings for several devices, i.e. Nexus 7k's, cat 3750x. cat 3850x.  It is not all stacks though, most are collected accurately only a few are not showing up. 
    All four of my Nexus 7k's are not collected accurately.
    Also when I goto Detail/Voice-video dashboards,  I do not get any MOS, DSCP, voice call, IPSLA stats etc etc
    Just for clarification we use Microsoft Lync for communications with Polycom phones using dscp 46, so perhaps it is not even possible but I wouod think Prime would be polling off of traffic on the port and look for DSCP values.
    I am able to poll IPSLA and mos scores via PRTG.
    on many of my ports in Detail Dashboards/Interface "polling enabled" shows as "no"  I am not sure why it shows up as no but there is some date being polled. 
    Is there something simple I am missing?  TAC does not seem to know the product and I am unable to find a decent manual.  So I am at a loss. 
    Thanks in advance!

    Bump

Maybe you are looking for

  • Dynamic photo gallery with XML

    My photo gallery works fine when I test movie in gallery.fla I have a thumbnail scroller that moves the thumbnails right when you move mouse left and left when you move mouse right. When you click on a thumb a larger picture is displayed. This all wo

  • SQL-Loader and Pipes

    I have to insert 300.000.000 datasets (generated dynamically by a seperate process) into an Oracle 8.1.6 database. I'd like to do this via SQL-Loader but since Linux (kernel 2.2 at least) supports only files up to 2Gigs and I don't have the necessary

  • How to continuous data acquisition and save to an excel file using vc++

    Hi, I’m trying to build an MFC application with MSVC++6, where I would continuously acquire samples from 2 channels of a USB-6289. I’m using the DAQmx C functions.  I use the following codes to continuously get data: DAQmxErrChk(DAQmxCreateAIVoltageC

  • Monitor keeps sleeping after hp update

    My computer alarted for an hp update, so I click it and once my computer turned off. The next day, I restarted it and it finished the update. However, after it finished the update, my screen went into sleep mode. I have tried to restart my computer,

  • Filling Cache for a Web Template

    HI Folks, We are in BI7.0. We have some reports which are taking huge amount of time to get executed. So we would like to fill the OLAP cache for these reports. I know the concept of pre calculating web templates in BW3.5. I am not sure, whether do w