Prime Infrastructure 2.0 possible to grab SNMP poll from WAN?
Our objective is to monitor all our network devices using Cisco Prime Infrastructure 2.0 which include LAN site and WAN site. LAN site we have various of equipments example cisco router 3800, ASA 5510, Catalyst switch 6500 and other access switches. WAN site we have ASA 5520. Currently our ASA is located at ISP which has its own public IP. Question is, it is possible to monitor our ASA 5520 which at WAN site? Attached is our topology sample.
Note: We has no issues on monitoring LAN equipments.
Hi Remysyaku
Are you able to do snmp polling on ASA from any other software like net-snmp etc.
I mean you need to check whther problem is snmp connectivity or PI is not able to manage ASA.
Also there is a bug due to which ASA5515x will be shown as unsupported in PI 2.0 but ASA 5520 and further should show managed correctly.
Thanks
Mahavir
Similar Messages
-
SNMP Polling from UCS Manager 1.4
I am having trouble with SNMP Polling from UCS Manager 1.4(1j).
I seem to only get SNMP data from Nexus such as those described in (http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/mib/reference/NX5000_MIBRef.html) I don't see any OIDs corresponding to those mentioned specifically for UCS listed in (ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-manager-supportlist.html).
Documentation on the cisco web site said that UCS Manager 1.4(1) and above will have MIBS such as CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB available.
Is there a separate IP addresses I should poll for these or any specific things that need to be set up?
I am not sure how we can gain access to the UCS related MIB objects exactly. The description on SNMP enable for UCS Manager is very brief (http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/1.4/UCSM_GUI_Configuration_Guide_1_4_chapter6.html#task_2054446421216050764)
It only described the community string set up under UCS Manager ->Admin->Communication Management -> Communication Services, bu didn’t really say anything about which IP addresses from the Management Interfaces should be used to get them.
Has anyone successfully polled data from say the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB and be able to help?
Thanks in advance.Yes indeed.
I learnt about the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB and the other Cisco UCS Manager MIB Support list by selecting UCS Manager under the Unified Computing drop down on this http page you quoted.
(http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/mib/reference/UCS_MIBRef.html)
Is there anything specific from those docs you are referring to that would make it such that we get the Nexus MIBs rather than ones under UCS Manager?
The two IP addresses for Fabric Interconnect A and B under Management Interface only give us info from MIBs listed under the Nexus documentation only. Nothing fir say 1.3.6.1.4.1.9.9.719.1.15.
No SNMP data form the virtual IP address.
Not sure where data under 1.3.6.1.4.1.9.9.719.1.15 would be accessible -
Cisco Prime Infrastructure 2.0 - no traps/info are pushed from devices
Good evening,
I have setup Cisco Prime Infrastructure 2.0 and, though I have added manually my 4 network cores as devices without any problem, I can't get a single trap or a single SNMP information to be pushed into my Cisco Prime Infra.
Here is my SNMP config on my core :
snmp-server user *edited* *edited* v3
snmp-server group *edited* v3 noauth notify *tv.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF.FFFFFFFF0F
snmp-server community *edited* RO
snmp-server enable traps snmp authentication linkdown linkup coldstart warmstart
snmp-server enable traps flowmon
snmp-server enable traps transceiver all
snmp-server enable traps call-home message-send-fail server-fail
snmp-server enable traps tty
snmp-server enable traps rf
snmp-server enable traps memory
snmp-server enable traps cpu_threshold
snmp-server enable traps eigrp
snmp-server enable traps ospf state-change
snmp-server enable traps ospf errors
snmp-server enable traps ospf retransmit
snmp-server enable traps ospf lsa
snmp-server enable traps ospf cisco-specific state-change nssa-trans-change
snmp-server enable traps ospf cisco-specific state-change shamlink interface
snmp-server enable traps ospf cisco-specific state-change shamlink neighbor
snmp-server enable traps ospf cisco-specific errors
snmp-server enable traps ospf cisco-specific retransmit
snmp-server enable traps ospf cisco-specific lsa
snmp-server enable traps flex-links status
snmp-server enable traps fru-ctrl
snmp-server enable traps entity
snmp-server enable traps ethernet cfm cc mep-up mep-down cross-connect loop config
snmp-server enable traps ethernet cfm crosscheck mep-missing mep-unknown service-up
snmp-server enable traps ether-oam
snmp-server enable traps aaa_server
snmp-server enable traps flash insertion removal
snmp-server enable traps l2tc threshold sys-threshold
snmp-server enable traps power-ethernet police
snmp-server enable traps rep
snmp-server enable traps vswitch dual-active vsl
snmp-server enable traps udld link-fail-rpt status-change
snmp-server enable traps vtp
snmp-server enable traps vlancreate
snmp-server enable traps vlandelete
snmp-server enable traps auth-framework sec-violation
snmp-server enable traps dot1x auth-fail-vlan guest-vlan no-auth-fail-vlan no-guest-vlan
snmp-server enable traps envmon fan shutdown supply temperature status
snmp-server enable traps entity-diag boot-up-fail hm-test-recover hm-thresh-reached scheduled-test-fail
snmp-server enable traps port-security
snmp-server enable traps ethernet evc status create delete
snmp-server enable traps energywise
snmp-server enable traps ipsla
snmp-server enable traps vstack
snmp-server enable traps bfd
snmp-server enable traps bgp
snmp-server enable traps bulkstat collection transfer
snmp-server enable traps cef resource-failure peer-state-change peer-fib-state-change inconsistency
snmp-server enable traps config-copy
snmp-server enable traps config
snmp-server enable traps config-ctid
snmp-server enable traps event-manager
snmp-server enable traps hsrp
snmp-server enable traps ipmulticast
snmp-server enable traps isis
snmp-server enable traps msdp
snmp-server enable traps pim neighbor-change rp-mapping-change invalid-pim-message
snmp-server enable traps bridge newroot topologychange
snmp-server enable traps stpx inconsistency root-inconsistency loop-inconsistency
snmp-server enable traps syslog
snmp-server enable traps isakmp policy add
snmp-server enable traps isakmp policy delete
snmp-server enable traps isakmp tunnel start
snmp-server enable traps isakmp tunnel stop
snmp-server enable traps ipsec cryptomap add
snmp-server enable traps ipsec cryptomap delete
snmp-server enable traps ipsec cryptomap attach
snmp-server enable traps ipsec cryptomap detach
snmp-server enable traps ipsec tunnel start
snmp-server enable traps ipsec tunnel stop
snmp-server enable traps ipsec too-many-sas
snmp-server enable traps errdisable
snmp-server enable traps ethernet cfm alarm
snmp-server enable traps vlan-membership
snmp-server enable traps mac-notification change move threshold
snmp-server enable traps vrfmib vrf-up vrf-down vnet-trunk-up vnet-trunk-down
snmp-server host *ip-address-edited* version 3 noauth *edited*
Basically all traps are enabled but absolutely nothing is showing up in my Prime Infra except that my 4 devices are "Reachable".
Here is a show snmp on the same device :
sh snmp
Chassis: *S/N Edited*
38554534 SNMP packets input
0 Bad SNMP version errors
14 Unknown community name
0 Illegal operation for community name supplied
0 Encoding errors
38453185 Number of requested variables
0 Number of altered variables
17790703 Get-request PDUs
20583581 Get-next PDUs
0 Set-request PDUs
0 Input queue packet drops (Maximum queue size 1000)
38490708 SNMP packets output
0 Too big errors (Maximum packet size 1500)
0 No such name errors
0 Bad values errors
0 General errors
38371069 Response PDUs
13 Trap PDUs
SNMP global trap: enabled
SNMP agent enabled
SNMP logging: enabled
Logging to *edited*, 0/10, 13 sent, 0 dropped.
Can anyone point out what is wrong or missing in my configuration? I can't seem to single it out myself.
Thanks
JeremyHi Jeremy,
SNMP traps are shown in the events and alerts section of PI.
SNMP config looks fine. Can you run the SNMP debug (debug snmp packets ) .check the logs and see if the device is actually sending the TRAPS to the PI server.
Thanks-
Afroz
[Do rate the useful post]
****Ratings Encourages Contributors **** -
Prime Infrastructure 2.x - Possible to Install On Own Hardware NOT as a VM?
Hi All -
At my company, we're doing everything we can to improve PI performance, but it's still god-awful slow.
- 24 GB RAM
- 16 vCPUs
- Moved it to its own ESXi host
Has anyone heard of taking the ISO and installing PI on your own bare-metal server with crazy specs?
Or, installing the PI application on top of your own Redhat Enterprise server, again with crazy specs?
We have 82 WLCs and thousands of LAPs in our implementation. We haven't even added switches or autonomous APs yet!
We've followed all recommendations in the Performance Tuning section of the system guide.
Ideas?
Thanks!I have attached the output of ps -ef, and I notice there are many instances of some processes, like:
migration
ksoftirqd
kblockd
oraclewcs
Also, CPU utilization shown:
ade # mpstat -P ALL
Linux 2.6.18-238.1.1.el5 (scea4nms2001) 12/30/14
16:31:16 CPU %user %nice %sys %iowait %irq %soft %steal %idle intr/s
16:31:16 all 24.26 0.00 2.30 8.62 0.13 1.46 0.00 63.23 1227.89
16:31:16 0 22.01 0.00 1.82 0.34 0.00 1.28 0.00 74.55 251.97
16:31:16 1 21.97 0.00 1.95 0.35 0.07 1.49 0.00 74.16 66.04
16:31:16 2 23.41 0.00 1.96 0.30 0.00 1.37 0.00 72.96 0.00
16:31:16 3 23.41 0.00 1.95 0.30 0.00 1.37 0.00 72.97 0.00
16:31:16 4 23.39 0.00 1.95 0.30 0.00 1.38 0.00 72.98 0.00
16:31:16 5 23.35 0.00 1.95 0.29 0.00 1.38 0.00 73.02 0.00
16:31:16 6 23.42 0.00 1.95 0.30 0.00 1.38 0.00 72.96 0.00
16:31:16 7 23.32 0.00 1.95 0.29 0.00 1.38 0.00 73.05 0.00
16:31:16 8 25.56 0.00 2.17 11.12 0.00 1.20 0.00 59.95 0.00
16:31:16 9 25.53 0.00 2.18 11.12 0.00 1.19 0.00 59.97 0.00
16:31:16 10 25.48 0.00 2.17 11.09 0.00 1.19 0.00 60.07 0.00
16:31:16 11 25.39 0.00 2.15 11.11 0.00 1.19 0.00 60.16 0.00
16:31:16 12 25.34 0.00 2.15 11.11 0.00 1.19 0.00 60.21 0.00
16:31:16 13 25.24 0.00 2.14 11.12 0.00 1.19 0.00 60.30 2.36
16:31:16 14 25.24 0.00 3.44 31.44 0.61 2.00 0.00 37.28 302.52
16:31:16 15 26.10 0.00 4.87 37.54 1.45 3.17 0.00 26.88 605.00
ade # -
Cisco prime infrastructure 2.0 inventory SFP
hello,
anyone knows if it is possible with cisco prime infrastructure 2.0 create inventory to obtain data from SFP (serial number and model)?
thank youHi ,
Can you try the below report and see if you are able to see the information , you are looking for
Report > Report Launch Pad > Device > Detailed Hardware
Thanks-
Afroz
***Ratings Encourages Contributors **** -
Monitoring Power Supplies in Prime Infrastructure 2.1
Hi,
Prime Infrastructure is capable of monitoring the power supplies from Cisco devices? Where can I see this feature on PI 2.1? is there any option to enable this, if it's capable?
ThanksThere are two options :
1. You poll the devices for Power supply and see the report based on it.
2. You can configure your devices for environment traps and the device will send traps to PI which can be used as an alert/Alarm in PI.
Envmon traps in Cisco devices can be configured using snmp-server enable traps envmon command.
This command enables or disables Environmental Monitor (EnvMon) status notifications for supported systems. Cisco enterprise EnvMon notifications are triggered when an environmental threshold is exceeded. If none of the optional keywords are specified, all available environmental notifications are enabled.
When the shutdown keyword is used, a ciscoEnvMonShutdownNotification (enterprise MIB OID 1.3.6.1.4.1.9.9.13.3.1) is sent if the environmental monitor detects a testpoint reaching a critical state and is about to initiate a shutdown.
When the voltage keyword is used, a ciscoEnvMonVoltageNotification (enterprise MIB OID 1.3.6.1.4.1.9.9.13.3.2) is sent if the voltage measured at a given testpoint is outside the normal range for the testpoint (that is, at the warning, critical, or shutdown stage). For access servers, this notification is defined as the caemVoltageNotification (enterprise MIB OID 1.3.6.1.4.1.9.9.61.2.2).
When the temperature keyword is used, a ciscoEnvMonTemperatureNotification (enterprise MIB OID 1.3.6.1.4.1.9.9.13.3.3) is sent if the temperature measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). For access servers, this notification is defined as the caemTemperatureNotification (enterprise MIB OID 1.3.6.1.4.1.9.9.61.2.1).
When the fan keyword is used, a ciscoEnvMonFanNotification (enterprise MIB OID 1.3.6.1.4.1.9.9.13.3.4) is sent if any one of the fans in a fan array fails.
When the supply keyword is used, a ciscoEnvMonRedundantSupplyNotification (enterprise MIB OID 1.3.6.1.4.1.9.9.13.2.5) is sent if a redundant power supply fails.
For a complete description of these notifications and additional MIB functions, see the CISCO-ENVMON-MIB.my and CISCO-ACCESS-ENVMON-MIB.my files, available on Cisco.com at http://www.cisco.com/public/mibs/v2/.
Status of the Environmental Monitor can be viewed using the show environment command.
The snmp-server enable traps envmon command is used in conjunction with the snmp-server host command. Use the snmp-server host command to specify which host or hosts receive SNMP notifications. To send SNMP notifications, you must configure at least one snmp-server host command.
HTH
-Thanks
Vinod
**Encourage Contributors. RATE Them.** -
Prime Infrastructure 1.1 LMS and NCS installation.
Dear all
I have purchase below mention product. Now my question is that.
A> 1). Prime (2). LMS 4.2 (2). NCS 1.1 are they different software and has to install them separately ?
B> or The prime is the only virtual(.ova) software where there LMS and NCS works as a feature?
C> Please help me with the download link and installation guide..
CISCO
R-PI-1.1-K9
Cisco Prime Infrastructure 1.1
CISCO
R-PI-1.1-100-K9
Prime Infrastructure 1.1 Software - 100 Device Base Lic
CISCO
L-PILMS42-100
Prime Infrastructure LMS 4.2 - 100 Device Base Lic
CISCO
L-PINCS11-100
Prime Infrastructure NCS 1.1 - 100 Device Base Lic
CISCO
L-PINCSW11-100
Prime Infrastructure NCS WAN 1.1 - 100 Device Base Lic
With Regards
Tanmay
[email protected]SOme of the similar discussion happened here, which would be helpful.
To answer your questions :
A.> Yes all three of them are separate software.
LMS :--> Ciscoworks Prime LMS is about to be end-of-life software which will phase out in favour of its successor Cisco Prime Infrastructure. This Software was the key application from Cisco to help manage the entire Wired Infrastructure for cisco devices, like Routers, switches, VPN, FW's, etc.
NCS:--> Wireless Control System (WCS) was the LMS equivalent software to manage Cisco's wireless infrastructure. It evolved as a new Generation Network Control System (NCS).
Cisco Prime Infrastructure :--> Cisco felt market demand to have a unified experience to manage both Wired and Wireless Infrastructure, hence Cisco Prime Infrastructure was introduced which is NCS+LMS. Not all features of LMS are migrated, hence customer's are allowed to use LMS latest version 4.2.x for wired network devices, if required.
B.> Prime is now provided with an inbaked Linux kernel to remove dependency from Windows or Unix (Solaris) OS, hence it is only available as OVA deployment image to be used under virtualized environment and can take benefit of virtualized infrastructure.
FOllowing are the download links :
Download LMS 4.2 here
Download PI 2.1 here
-Thanks
Vinod
**Encourage Contributors. RATE Them.** -
Default netflow port in Prime Infrastructure 1.3
Is there any way to change the default port Prime Infrastructure Assurance 1.3 listens for Netflow on from 9991 to 9996?
I don't think so.
The PI 1.3 docs are pretty silent on Assurance but the Prime Assurance Manager 1.1 Quick Start Guide notes that port 9991 must be open for the Netflow Data Receiver -
Cisco Prime Infrastructure 1.3, Mail Configuration
Hi,
I have a Cisco Prime Infrastructure 1.3 and I want to set up the mail. When I test it, I get this error:
Failed to send mail to primary SMTP server. Failed to send mail to secondary SMTP server. Please make sure that you save mail configuration by hitting 'Save' button.
I have the ip address, and the username and password. Do I need to create a new buzon for the prime? because by default the "From" field appears with
[email protected]
Thanks!!Some extra info that has just come to my attention. At one point we were running (we're actually still running) CiscoWorks with LMS3.2 and Cisco NCS 1.x. I merged these two things together into Cisco Prime Infrastructure (upgraded the licensing to get 450 lifecycle licenses to cover the APs + all of the devices coming from LMS3.2). I followed all of the documented procedures to upgrade the NCS appliance to Prime Infrastructure. But when I type "show application" from the CLI of the NCS appliance (now the Prime Infrastructure appliance) I see this:
HQ-NCS1/admin# show application
NCS Cisco Prime Network Control System
Is that normal? Maybe this is my problem. Should this output list "Cisco Prime Infrastructure" instead of (or in addtion to) Cisco Prime Network Control System? When I login to the GUI it shows "Cisco Prime Infrastructure" and the GUI has changed considerably (menus are different) so I'm assuming that the application upgrades I launched from the CLI to go to Prime Infrastructure worked fine. -
Cisco Prime Infrastructure Scheduled Configuration Archive not executing
We have a deployment of Cisco Prime Infrastrcuture 1.3 (1.3.0.20).
Configuration Archive is a feature that collects and archives the device configurations i.e. cisco switches.
You have an option to schedule this to run, say daily, weekly etc. Once scheduled you can see it in the "Jobs Dashboard" and with the "next start time" of what you configured. I have a situation whereby the time it is suppose to start - it doesnt - howevere flags the job as a "success". Not newe device configurations are archived and the "next start time" remain the same. Its almost like it is failing to execute, but some other process under the hood thinks that it was been executed correctly?
Any ideas or experience that could help here would be appreciated!Some extra info that has just come to my attention. At one point we were running (we're actually still running) CiscoWorks with LMS3.2 and Cisco NCS 1.x. I merged these two things together into Cisco Prime Infrastructure (upgraded the licensing to get 450 lifecycle licenses to cover the APs + all of the devices coming from LMS3.2). I followed all of the documented procedures to upgrade the NCS appliance to Prime Infrastructure. But when I type "show application" from the CLI of the NCS appliance (now the Prime Infrastructure appliance) I see this:
HQ-NCS1/admin# show application
NCS Cisco Prime Network Control System
Is that normal? Maybe this is my problem. Should this output list "Cisco Prime Infrastructure" instead of (or in addtion to) Cisco Prime Network Control System? When I login to the GUI it shows "Cisco Prime Infrastructure" and the GUI has changed considerably (menus are different) so I'm assuming that the application upgrades I launched from the CLI to go to Prime Infrastructure worked fine. -
Prime Infrastructure 2.2 snmp-server location
We have implemented Cisco Prime Infrastructure 2.2 in our facility. We have each switch loaded in with an "snmp-server location" set for the switches for easier identification and quicker troubleshooting. We would like that location to show in the network topology map as well as in the email alerts it sends if one of those switches goes down. Is this something I am overlooking, and if so, can someone please explain to me how to make this happen?
Hi William,
snmp-server location is synced from the devices & also the info available in various report.
But, if i'm not wrong you want to customize the e-mail body of notifications sent out from the prime.
This functionality is no where discussed in PI user guide & i'm afraid not possible as of now.
Also, there's bug related to snmp-server location even retrieving it from the reports
CSCuj09556 : PI 2.0 corrupts device config by doing snmp set for location after sync
https://tools.cisco.com/bugsearch/bug/CSCuj09556
CSCuo16889 : PI 2.0 - Does not poll sysLocation for 3750 device
https://tools.cisco.com/bugsearch/bug/CSCuo16889
- Ashok
Please rate the post or mark as correct answer as it will help others looking for similar information -
Hello,
we're running Prime Infrastructure 2.0 (version VA-2.0.0.0.294).
I was scared as I figured out one hour ago that running an inventory sync (Device Work Center) removes the command snmp-server location and adds the command snmp-server host "PI-ip address" "snmp rw community" in the running-config.
Has someone the same behaviour or can reenact this scenario?!
Can someone imagine that this behaviour has something to do with a configuration setting in PI?
I'm perplexed and got gray hair now.
Thank you for your answers or tips.
BastianHello Rob,
I just successfully installed the patch. The snmp-server location is not touched anymore while running a inventory job.
But PI still enters this string in the running-configuration:
snmp-server host "PI-IP address" " our snmp RW community- string"
although there already exists the entry:
snmp-server host "PI-IP address" version 2c "community-string (not the snmp rw-community-string)"
Do you or anyone else has the same behaviour that PI adds automaically himself as snmp trap receiver with the SNMP-RW community?
Regards
Bastian -
Prime Infrastructure 2.1 - Fan-Failure SNMP-Trap Issue
Hello,
I am facing the following Prime Infrastructure (v2.1) issue:
- A Fan-Failure SNMP-Trap from a Cisco 3650 switch doesn't appear on Prime, but a Link-Failure from the same switch does.
- The both events appears on Prime with Syslog.
- The command "snmp-server enable traps envmon fan shutdown supply temperature status" is set up.
- The switch is in "Managed" state in PI, I have checked the ACL at the "snmp-server community" command, it is okay.
- I have set up an SNMP-Trace for the switch on PI, but only "SNMP Null was returned for class com.cisco.server.managedobjects.bridge.Fan3KStats attribute fanIndex" arrived. Please find the log below.
07/02/14 12:39:53.211 TRACE [presence-9] [] Adding attributes for object Fan3KStats[151206060_,1012]
07/02/14 12:39:53.211 TRACE [presence-9] [] Index name : fanIndex
07/02/14 12:39:53.211 TRACE [presence-9] [] Index Value : 1012
07/02/14 12:39:53.211 TRACE [presence-9] [] Device MIB table index: .1012
07/02/14 12:39:53.211 TRACE [presence-9] [] MIB table row index: .1012
07/02/14 12:39:53.211 TRACE [presence-9] [] OID for : fanIndex = 1.3.6.1.2.1.47.1.1.1.1.1.1012
07/02/14 12:39:53.211 TRACE [presence-9] [] OID for : fanOperStatus = 1.3.6.1.4.1.9.9.13.1.4.1.3.1012
07/02/14 12:39:53.211 TRACE [presence-9] [] Get fragment
07/02/14 12:39:53.211 TRACE [presence-9] [] Creating PDU: Get
07/02/14 12:39:53.211 TRACE [presence-9] [] VarBind OID=1.3.6.1.2.1.47.1.1.1.1.1.1010
07/02/14 12:39:53.211 TRACE [presence-9] [] VarBind OID=1.3.6.1.4.1.9.9.13.1.4.1.3.1010
07/02/14 12:39:53.211 TRACE [presence-9] [] VarBind OID=1.3.6.1.2.1.47.1.1.1.1.1.1011
07/02/14 12:39:53.211 TRACE [presence-9] [] VarBind OID=1.3.6.1.4.1.9.9.13.1.4.1.3.1011
07/02/14 12:39:53.211 TRACE [presence-9] [] VarBind OID=1.3.6.1.2.1.47.1.1.1.1.1.1012
07/02/14 12:39:53.211 TRACE [presence-9] [] VarBind OID=1.3.6.1.4.1.9.9.13.1.4.1.3.1012
07/02/14 12:39:53.218 TRACE [presence-9] [] Error Status: 0
07/02/14 12:39:53.218 TRACE [presence-9] [] Error index: 0
07/02/14 12:39:53.218 TRACE [presence-9] [] SNMP Null was returned for class com.cisco.server.managedobjects.bridge.Fan3KStats attribute fanIndex
07/02/14 12:39:53.218 TRACE [presence-9] [] Setting attribute: fanOperStatus
07/02/14 12:39:53.218 TRACE [presence-9] [] SnmpInt Value : ?
07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes, storing result, class=com.cisco.server.managedobjects.bridge.Fan3KStats, attr=fanOperStatus
07/02/14 12:39:53.218 TRACE [presence-9] [] SNMP Null was returned for class com.cisco.server.managedobjects.bridge.Fan3KStats attribute fanIndex
07/02/14 12:39:53.218 TRACE [presence-9] [] Setting attribute: fanOperStatus
07/02/14 12:39:53.218 TRACE [presence-9] [] SnmpInt Value : ?
07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes, storing result, class=com.cisco.server.managedobjects.bridge.Fan3KStats, attr=fanOperStatus
07/02/14 12:39:53.218 TRACE [presence-9] [] SNMP Null was returned for class com.cisco.server.managedobjects.bridge.Fan3KStats attribute fanIndex
07/02/14 12:39:53.218 TRACE [presence-9] [] Setting attribute: fanOperStatus
07/02/14 12:39:53.218 TRACE [presence-9] [] SnmpInt Value : ?
07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes, storing result, class=com.cisco.server.managedobjects.bridge.Fan3KStats, attr=fanOperStatus
07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes, assembling attributes
07/02/14 12:39:53.218 TRACE [presence-9] [] MIB lookup, OID for: powerSupplyIndex = 1.3.6.1.2.1.47.1.1.1.1.1
07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes needs class=com.cisco.server.managedobjects.bridge.PowerSupply3kStats, field=powerSupplyIndex
07/02/14 12:39:53.218 TRACE [presence-9] [] MIB lookup, OID for: powerSupplyOperStatus = 1.3.6.1.4.1.9.9.13.1.5.1.3
07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes needs class=com.cisco.server.managedobjects.bridge.PowerSupply3kStats, field=powerSupplyOperStatus
07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes invoked
07/02/14 12:39:53.218 TRACE [presence-9] [] GetMultiAttributes building OIDs for next PDU
07/02/14 12:39:53.218 TRACE [presence-9] [] Adding attributes for object PowerSupply3kStats[151206060_,1009]
- The switch sends the SNMP Trap, based on the followings:
Jul 7 13:38:30 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:30 UTC: %PLATFORM_THERMAL-6-FRU_FAN_OIR: Switch 1: System fan 1 removed
Jul 7 13:38:30 UTC: %PLATFORM_THERMAL-1-FRU_FAN_NOT_PRESENT: Switch 1: System fan 1 not present
Jul 7 13:38:30 UTC: SNMP: Queuing packet to IP_ADDRESS
Jul 7 13:38:30 UTC: SNMP: V2 Trap, reqid 33202, errstat 0, erridx 0
sysUpTime.0 = 576753333
snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, NotExist
ciscoEnvMonFanStatusEntry.3.1010 = 5
Jul 7 13:38:30 UTC: SNMP: Queuing packet to IP_ADDRESS
Jul 7 13:38:30 UTC: SNMP: V2 Trap, reqid 33203, errstat 0, erridx 0
sysUpTime.0 = 576753333
snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, NotExist
ciscoEnvMonFanStatusEntry.3.1010 = 5
Jul 7 13:38:30 UTC: SNMP: Queuing packet to IP_ADDRESS
Jul 7 13:38:30 UTC: SNMP: V2 Trap, reqid 33204, errstat 0, erridx 0
sysUpTime.0 = 576753333
snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, NotExist
ciscoEnvMonFanStatusEntry.3.1010 = 5
Jul 7 13:38:30 UTC: SNMP: Queuing packet to IP_ADDRESS
Jul 7 13:38:30 UTC: SNMP: V2 Trap, reqid 33205, errstat 0, erridx 0
sysUpTime.0 = 576753333
snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, NotExist
ciscoEnvMonFanStatusEntry.3.1010 = 5
Jul 7 13:38:31 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:31 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:31 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:31 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:45 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:51 UTC: %PLATFORM_THERMAL-6-FRU_FAN_OIR: Switch 1: System fan 1 inserted
Jul 7 13:38:54 UTC: SNMP: Queuing packet to IP_ADDRESS
Jul 7 13:38:54 UTC: SNMP: V2 Trap, reqid 33206, errstat 0, erridx 0
sysUpTime.0 = 576755733
snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, Normal
ciscoEnvMonFanStatusEntry.3.1010 = 1
Jul 7 13:38:54 UTC: SNMP: Queuing packet to IP_ADDRESS
Jul 7 13:38:54 UTC: SNMP: V2 Trap, reqid 33207, errstat 0, erridx 0
sysUpTime.0 = 576755733
snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, Normal
ciscoEnvMonFanStatusEntry.3.1010 = 1
Jul 7 13:38:54 UTC: SNMP: Queuing packet to IP_ADDRESS
Jul 7 13:38:54 UTC: SNMP: V2 Trap, reqid 33208, errstat 0, erridx 0
sysUpTime.0 = 576755733
snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, Normal
ciscoEnvMonFanStatusEntry.3.1010 = 1
Jul 7 13:38:54 UTC: SNMP: Queuing packet to IP_ADDRESS
Jul 7 13:38:54 UTC: SNMP: V2 Trap, reqid 33209, errstat 0, erridx 0
sysUpTime.0 = 576755733
snmpTrapOID.0 = ciscoEnvMonMIBNotifications.8
ciscoEnvMonFanStatusEntry.2.1010 = Switch 1 - FAN 1, Normal
ciscoEnvMonFanStatusEntry.3.1010 = 1
Jul 7 13:38:55 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:55 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:55 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
Jul 7 13:38:55 UTC: SNMP: Packet sent via UDP to IP_ADDRESS
It seems like PI and the switch doesn't understand each other concerning the fan...
Thanks for any ideas, comments and feedbacks,
CsabaI have the very same problem.
The switch has a power supply error (one of the two is down). There is the syslog message in PI about it, but no event has created, so nor alarm is there as well.
When I check the status of the switch in the Device Work Center, and choose the Environment in Device Details I can see that PI has not realized the power supply error.
However when I click on the Sync for this very device the power supply status is updated, but still no event or alarm.
This is the case with the FANs as well. -
Cisco Prime Infrastructure 1.4 SNMP Traps are not converted into Alarms
Hi everybody,
I just configured SNMP Traps on a Cisco Catalyst 3750-x to send to our Cisco Prime Infrastructure 1.4 Appliance.
Now I forced the Switch to send some traps (Power off a Power Supply, Interface errdisable). The only events I see in Alarms & Events on PI is the same information message everytime:
Configuration management event has been recorded in ccmHistoryEventTable.
I think the forced traps should be converted into alarms? Why can't I see them?
Thanks,
MarcOk, I started debugging as you said. I get the following output:
Mar 13 09:28:13.711: SNMP: V2 Trap, reqid 11689, errstat 0, erridx 0
sysUpTime.0 = 198609846
snmpTrapOID.0 = ciscoSyslogMIB.2.0.1
clogHistoryEntry.2.1688 = PM
clogHistoryEntry.3.1688 = 5
clogHistoryEntry.4.1688 = ERR_RECOVER
clogHistoryEntry.5.1688 = Attempting to recover from bpduguard err-disable state on Gi1/0/13
clogHistoryEntry.6.1688 = 198609844
Mar 13 09:28:13.737: SNMP: Queuing packet to xx.xx.xx.xx
Looks like the Switch is sending SNMP Traps from the ciscoSyslogMIB. Is this why PI can't show the Traps and convert it into a alarm?
After this test I configured logging (syslog) to the PI. Now the errors are showed but still not converted into alarms. I just want to be notified by email when such errors occurs.
Thanks,
Marc -
Is it possible to manage the switch SMB 300 series using Cisco Prime Infrastructure?
Is it possible to manage the switch SMB 300 series using Cisco Prime Infrastructure 1.2?
SF300 series is targeted for support in PI 2.0.
Maybe you are looking for
-
Communication problem between ASA 5510 and Cisco 3750, L2 Decode drops
Having problem with communication between ASA 5510 an Cisco Catalyst 3750. Here is the Cisco switch port facing the ASA 5510 configuration: interface FastEthernet2/0/6 description Trunk to ASA 5510 switchport trunk encapsulation dot1q switchport trun
-
Hi When i am trying to open query I can able to see the the query when I click on Change it is giving error message. "Inconsistency in loading. Please check use of deleted objects" When I try to execute that query it is giving error and disconnecting
-
What is so "Pro" about the MacBook Pro?
"Pro" is short for professional and the Apple brand has been synonymous with creative professionals for at least 20 years... I know, asI am one of them. Now, the MAC PRO (tower) is no doubt, a professional grade machine. With 4 hard drives, 2 DVD dr
-
When trying to open a PDF format using Adobe XI I get an error message that there's a problem opening the document (57)
-
How can I synchronize the photos and videos on my iphone with my mac mini or macbook pro?
Hello, I took some pictures and videos with my iphone 4s. Now I want to synchronize them with my mac mini and my macbook pro. But when I try to sync it via iTunes I can only sync from mac to iphone but not from iphone to mac. If I import them via iph