Prime Infrastructure 2.1 - Power supply alarms on switchs

Hi,
How can i manage to get a email if one of my power supply on a switch die (see the attached file).
I tried to activate all snmp traps possible on my switch and all i can get is configuration management events on PI.
I changed the Severity Configuration on PI for Environmental monitor detects a testpoint reaching a critical state to critical.
Any ideas?
Sorry for grammar, english is not my native language.
*** Prime Infrastructure 2.1, we will upgrade for 2.2 in few weeks***

Hello,
It's tracked by the following bug:
CSCui46231    Processing Alarm on power supply failure and Fan failure conditions 
Should be resolved in PI 2.2
Ram

Similar Messages

  • Prime 2.2 Power supply alarms

    doing some testing in a new data centre with Prime 2.2 and wondering if there is a way to be immediately notified in the event I lose a power supply or a fan.
    I thought I had all the monitoring turned on but when I pulled a power supply I had to re-sync the device before Prime knew about it and then it still never notfied me.

    hey
    i have issue aswell to get snmp poll working optimal so atm in pi i am working more on snmp trap and syslog as the way to get the notification.
    snmp-server trap-source [interface]
    snmp-server host [pi-ip] (vrf [vrf name]) version 2c [community string]
    snmp-server enable traps envmon supply
    secend minor issue is pi only set this a minor error so if you treshold on email notification is set to  critical you wil never get and email alarm so if that is a must you must edit the servirity og the alarm og send warning email as well

  • Cisco Prime Infrastructure and no new events / alarms since update to 2.2.1

    Hello,
    I have upgraded our Cisco Prime Infrastructure from version 2.1 to 2.2.1 (with a backup and restore). We have round about 700 APs and three 5208 Controller. So far everything seems to work really fine. The only problem is that there are no new alarms/events under "Monitor", "Alarms and Events".
    The last entries (events and alarms) are dated before the upgrade. Other informations (like client counts for example) are correct.
    Is there a known bug related to my problem? Can anybody help?
    Thanks

    I have done some research:
    I see the following problems in the log-package (downloaded from Prime):
    ===
    <msg time='2015-04-07T12:10:50.620+02:00' org_id='oracle' comp_id='rdbms'
     client_id='' type='UNKNOWN' level='16'
     host_id='rzprime' host_addr='xxx.xxx.xxx.xxx' module='JDBC Thin Client'
     pid='9499'>
     <txt>ORA-1652: unable to extend temp segment by 128 in tablespace                 TS_EVENTS 
     </txt>
    </msg>
    <msg time='2015-04-07T12:10:50.727+02:00' org_id='oracle' comp_id='rdbms'
     client_id='' type='UNKNOWN' level='16'
     host_id='rzprime' host_addr='xxx.xxx.xxx.xxx' module='JDBC Thin Client'
     pid='15177'>
     <txt>ORA-1652: unable to extend temp segment by 128 in tablespace                 TS_EVENTS 
     </txt>
    </msg>
    ===
    I think that there is a problem with a too small tablespace. But I can´t fix that. Anybody? ;)

  • Prime Infrastructure 2.1 - SFP port alarms to email/show total network traffic speed

    Hello,
    Running Prime Infrastructure 2.1 with assurance license.
    I have two questions:
    1. Setting up alarms in PI 2.1. I've set up a port group of my main switches that have TenGig links to our main router. I have set up a monitor template that has only interface availability on it and then deployed it. In theory, this should email me, the contact (where I put my email address in), when the ports that I have set up go down, correct?
    2. I want to monitor the entire traffic of the network going in to the router from our TenGig ports. I've messed around with the dashlets and adding my port group to the WAN utilization dashlet but only see % of utilization. I'd like to be able to see raw traffic stats from those ports. I'm sure I'm missing something. Where do I need to look in PI to check raw traffic data in Mbps/Gbps from my ports. 

    In my first question, I do not get an email when a port goes down. I set up a test port and when I pulled it, after about 10 minutes, it had never sent me an email. I will continue to look through what I've been doing to see if I can figure it out.

  • Cisco Prime Infrastructure 2.0 not showing alerts from switch

    Hello,
    I have a prime  infrastructure 2.0 running at a customer place and the customer now complains that he is not receiving link up/down messages from the switch. When i checked I have seen that if I shut down a port in the switch the prime identifies after a long time, but its not generating an alarm still. How can I fine tune the prime to fix this issue. Please help on this.
    Thanks in advance

    Hi,
    Same problem here.
    I am using Cisco Prime Infrastructure 2.0 (evaluation version for 60 days). I want to deploy port monitoring for my trunk ports between switches and some other important ports e.g. servers. Basically I want to get alarms when these ports are down, there are errors on ports and etc.
    So in Design>Port Grouping I created User Defined group with important ports. In Deploy>Monitoring Deployment I selected Interface Health (default)>Deploy selected Port Groups and when selected port group I created.
    Now the rule shows Deployed: Yes and Status: Active. After that I just pulled out one port which was in monitored group, waited 5min as it is set in Interface Health (default) template, and nothing happened, and worse, alarms started to show up of other ports where regular users are connected (computers was turned off), which I do not want to see at all. I tried redeploy template, I even created my own template but still no desired result.
    Any suggestions how to make port monitoring work?

  • Power supply error, Cisco switch 3750

    Hello,
    Can someone help me with a  power supply problem...?
    Switch cisco WS-C3750-24P is showing "Unavail" from sh env all
    Switch3750#sh env all
    FAN is OK
    TEMPERATURE is OK
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    1  Built-in                                         Unavail
    2  Built-in                                         Good
    3  Built-in                                         Good
    4  Built-in                                         Good
    Does it means that power supply 1 was removed? failed?
    Do you know about another command to see more details?
    Thanks,

    Hi All,
    Can you please help to fix the issue,
    sw03#sh env all
    FAN is OK
    TEMPERATURE is OK
    Temperature Value: 45 Degree Celsius
    Temperature State: GREEN
    Yellow Threshold : 58 Degree Celsius
    Red Threshold    : 68 Degree Celsius
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    1  Built-in                                         Unavail
    SW  Status          RPS Name          RPS Serial#  RPS Port#
    1   Active          <>
    sw03#sh env st
    SWITCH: 1
    FAN is OK
    TEMPERATURE is OK
    Temperature Value: 45 Degree Celsius
    Temperature State: GREEN
    Yellow Threshold : 58 Degree Celsius
    Red Threshold    : 68 Degree Celsius
    POWER is FAULTY
    RPS is SUPPLYING
    As per the sh env stack, seem like power is faulty ?. Can Someone please tell how to rectify the problem.
    Madan

  • Cisco Prime Infrastructure - Is there a report of unused switch ports?

    Hello,
    Is there a report in Cisco Prime Infrastructure 1.4 showing the unused switch ports?
    There used to be one in Cisco Prime LMS (Reclaim Unused Up/Down Ports Report).
    Thank you,
    Luke

    Hello,
    I now have Cisco Prime Infrastructure 2.0 running, and I don't see a report like the "Reclaim Unused Up/Down Ports" report that existed in LMS.
    I found one called "Interface Capacity", but it only shows the number of ports that are "connected", "notconnect" or "disabled".
    Does anyone know if a report of Unused ports exists in Prime Infrastructure 2.0 or if it will be available later on?
    Thank you,
    Luke

  • Cisco Prime Infrastructure 2.2: Catalyst 2960X-24TS-LL Switch Collection Failure

    Hello,
    I've Upgraded Prime Infrastructure to Version 2.2.0.0.158. Now our Catalyst 2960X-24TS-LL switches show an error message, when they are added to the inventory. The error is as follows:
    Partial Collection Failure; Collection Status : Failed feature(s).
    The 2960X-24TS-LL is listed under the supported devices list and other switches (e.g. WS-C2960X-48FPS-L) got inventorized without any problems.
    Did anybody see this issue and can tell me how to solve it.
    - Benjamin

     - Getting that one too, since running 2.2 (Failed Features) ; suggest opening a TAC case.
    M.

  • Two dc power supply precisely timed switching

    Hi,
    i am trying to controll switching  between two E3631A DC Power supply with different period,in my programm i am using to timed switching  case structur for controlling DC Power switch,but because of kommunication overhead doesn‘t  timing result  always agree with specified period,how can i modify my code to precisely controll this Switching?if f anyone can give me some ideas that would be appreciated.
    Note:Labview 2009 sp1
    Solved!
    Go to Solution.
    Attachments:
    power switch.vi ‏70 KB

    Dennis_Knutson wrote:
    The on/off is part of the Configure Output function with the Enable input. There is going to be some lag between enabling the supplies because the commands will execute sequentially. It might be possible to set them both to software triggering and then issue a GET (Group Execute Trigger) bus command. That would be as close to switching them on at the same time as you are going to get. It has been a while since I've done this. I know the lower level GPIB functions has the TriggerList function for doing this but I'm not sure about VISA.
    A hardware switching solution does make more sense here since you seem to desire deterministic timing.  Windows is not going to get you reliable switch timing nor is the devices communications interface (The device needs to receive and process the command before the action is taken.)  Many power supplies also have  hardware trigger inputs and outputs and can be configured to execute actions on these line state transitions.  This gets around all the communications and processing lag of the controller and allows a rapid response. 
    Jeff

  • Prime Infrastructure 2.0 Link-Down Alarm severity level

    Hi,
    i have been looking for a way to lower the severity level of link-down Alarms. I use the threshhold utilization feature and want to generate an alarm when CPU or Memory goes over 90%, this works fine. Problem is that when you enable "Switches and Hubs" or "Routers" category to receive alarms under: Operate -> Alarms & Events -> Email Notifications, you define only Critical alarms should generate an email and Link-down is by default Critical.
    Well you figure that you should be able to change this, but i can't find anything to change the severity under: Administration -> System Settings -> Severity Configuration.
    Do anyone know if this is even possible? If so please tell me how..

    Hi,
    Yes it is possible.
    Changing Alarm Severities
    You can change the severity level for newly generated alarms
    Note Existing alarms remain unchanged.
    To change the severity level of newly generated alarms:
    Step 1 Choose Administration > System Settings .
    Step 2 Choose Severity Configuration from the left sidebar menu.
    Step 3 Select the check box of the alarm condition whose severity level you want to change.
    Step 4 From the Configure Severity Level drop-down list, choose the new severity level ( Critical , Major , Minor , Warning , Informational , or Reset to Default ).
    Step 5 Click Go, then click OK.
    Check the attached screen shot ..
    Thanks-
    Afroz
    ***Ratings Encourages Contributors ***

  • Prime Infrastructure 2.0 Link Status Alarms

    Hi,
    we are used SNMP traps sent from our core switches to our PI 1.3 server to notify us about link down events. In this scenario we got emails only for link down events on our core switches.
    Now, we are using PI 2.0. It seems PI 2.0 checks link status of all devices on its own. We got an email for a link down event on any of our switches. To avoid that I configured PI 2.0 to treat Link down events as Informational instead of Critical (Administration > System Settings > Severity Configuration, Link down). Now, we don't get email notification for link down events at all.
    Is there a way to configure PI 2.0 to inform us on link down events on our core switches, but not on a link down event on any of our other devices?
    Timo

    Disable the trap from the configuration on the switches you don't want to get messages from.  So depending on what kind of switch it would be something like:
    conf t
    no snmp-server enable traps linkdown linkup
    Your string may different, there are several options that can be included in this line.  You may have to remove the whole line and readd it with only the options you want.
    If this posts answers your question or is helpful, please consider rating it and/or marking as answered.

  • Which power supply for which switch

    have 2 different switchs with 2 different power supplys.
    EZXS88W v3 andEZXS16W v2.1 - i have a 9v and a 12v linksys power brick both @1000mha. which one goes to which?
    i also have a BEFSR81 v3 - with no powersupply. can anyone linkme to a GOOD seller on ebay or amazon for one please?

    EZXS88W power specs is 5V 6A, 3 PRONG and 100~240V.
    EZXS16W v2.1 Power specs is 12V 1000MA, BIG BARREL and 120VAC.
    BEFSR81 v3 Power specs is 12VDC 1000ma, BIG BARREL and 120VAC. 
    This are the specs for the power adapter for this devices. You will find this power adapter on any of the stores, or else you get a Universal Power Adapter which is compatible with all the Router and the Electronic Device. Just you need to adjust the power as per your Routers power specs. 

  • Why my hp 625 notebook needs the power supply cable to switch on ?

    i had windows 7 and now vista ....(don t ask)... .. although i have fully charged battery?

    The battery can register as charged but not actually put out enough juice to boot the machine. The only way to really test it is to get another known good battery. I assume this is the original battery and is at least a couple years old?

  • Cisco Prime Infrastructure 1.2 - web browser freezes when managing rogue APs alarms

    Hello all,
    has anybody faced a freezing problem when you click in Cisco Prime Infrastructure 1.2 down on alarm bar and then to Rogue AP alarms and then try to add an annotitation or change a rogue alarm to Friendly?
    I tried it on different PC, different browsers (Firefox 14.0.1. Chrome ...) and the problem is still there.
    Has anybody an idea?
    Thanks.
    Regards
    Karel

    I just tried it from my lab VM and had no problems.  I use Chrome and the browser does sometimes not refresh for a while but that is just when I start to  click around.
    Thanks,
    Scott
    Help out other by using the rating system and marking answered questions as "Answered"

  • Cisco Prime Infrastructure 1.3 - SNMPv3 can´t get CPU, memory info.

    Hi,
    I have a Cisco Prime Infrastructure 1.3 deployment with Catalyst 2960S switches. Switches are running IOS 15.0(2) SE2. All switches have SNMPv2 configured, and all appears to be fine. I'm migrating one switch to SNMPv3, and PI have reachability to the switch, but PI doesn´t receive traps from the switch, and neither poll CPU and memory information (all displays 0.00%).
    Somebody have a sample configuration of SNMPv3 with Cisco Prime (Infrastructure or LMS)? I cannot find a Cisco official (or unofficial) document related to this version, usually all mention SNMPv2.
    Thank you.
    Eduardo

    Hi Eduardo:
    SNMPv3 is indeed supported for general administration.  There's a bug with SWIM using SNMPv3 (CSCud92758), but you should be fine for just monitoring.  Have you deleted the switch, waited until Prime Infrastructure told you it was gone, then readded it as SNMPv3 natively?  Bug CSCug78869 keeps things from working well when changing SNMP versions. 
    If you don't have the new Update-1 patch for Prime Infrastructure 1.3.0.20 installed (filename PI_1.3.0.20_Update_1-12.tar.gz) installed, I'd suggest you get it.  While it's not going to specifically address this issue, there are a lot of really good fixes in it.
    Release Notes for Update 1 for Cisco Prime Infrastructure 1.3.0.20

Maybe you are looking for

  • Downloaded mavericks for one mac can i use the same download to install on another mac

    I have downloaded for 12 hours initial installation on one mac for mavericks, and all installed successfully. Rather than download again for another mac, can I use the same download and copy on to the other mac..and if yes, where will I find it?

  • "Open in Smart View" option. Hyperion Planning version 11.1.1.3

    Failure to download planning form to Smart View using the "Open in Smart View" option. Hyperion Planning version 11.1.1.3. Error message "Web launch operation has been cancelled. Your feedback is appreciated.

  • Problem in writing data to excel spread sheet

    Hi Folks, I have developed a jdbc application that writes data to excel spread sheet.while trying to write data to excel, it could not write date values properly.it is writing 00.00.0 for all the date feilds. Can some one help here. Thanks in advance

  • Target Disc Mode and only showing the windows partition:

    Hi, two weeks ago I purchased Aperture 2 for my MacBook Pro, and during the install, it stated that the install had failed and then froze. I did a hard-shutdown, and when I attempted to boot it back up, it kept trying to boot in Windows-- (It is runn

  • Execute ANYTYPE Parameter in pl/sql

    any one help me, its very important how to execute this procedure for insert data in table using type object CREATE OR REPLACE PROCEDURE gen_insert1 ( p_table VARCHAR2, p_anydata ANYDATA) IS l_statement VARCHAR2 (32767); BEGIN l_statement := ' DECLAR