Problem after makinf loopback adapter
after installing oracle I make the loopback adapter to calling the report
then this good
but when I connect to I nternet The report not calling but after disconnect fron Internet report work good
what is the solution
my windows xp2
database 10g R2
developer 19g
thanks
How are you making the call to the report
Similar Messages
-
Multicasting problem with MS Loopback Adapter
My IBM software dispatcher requires Microsoft Loopback Adapter on my Application Servers.
Unfortunatly, multicasting does not work with MS Loopback Adapter. I am running WebLogic
6.1 on Windows 2000 Application Server. Is this a known problem? Has it been fixed
in a Service Pack? Is there a way around it?
Thanks in advance,
Guylaine.
Installing Service Pack 2 for Windows 2000 AS fixed the problem.
Guylaine.
-
Why oracle 11g needs loopback adapter???
Hi
i have installed obi11g on my windows 32.
initially i couldnt install as microsoft loopback adapter wasnt configured on my system...
but after configuring loopback adapter on my system i am able to successfully installl.
my question is that why oracle need microsoft loopback adapter,
even though i hav manually assigned the ip address in the network configuration. tcp ip settings..
plz help guyshi mahis,
my question is that why oracle need microsoft loopback adapterIts a pre-requisite for OBIEE 11g to call the IP of the host file.It is defined that way,you can go through the documentation for it.
mahis,please mark points to your previous threads and close it along with this.Follow rules http://forums.oracle.com/forums/ann.jspa?annID=939
By,
KK -
Inventory and MS Loopback Adapter problem
I have a couple hundred imaged machines that all have a MS Loopback Adapter
in addition to the NIC used for network communication. The MAC address of
the loopback is always the same. For it's purpose, it is not a problem. For
whatever reason, ZEN inventory assigns the machines an inventory storer
string with this MAC number so that each inventory replaces the last. Only
the last machine inventoried is in the DB. Is there a fix?
Erick Larson
Perkins Library
Duke UniversityApparently, the tech who deployed the machines, deployed our image to one,
inventoried it, recaptured the image, imaged the rest and deployed the
machines with the same Inventory ID. That's my guess, anyway. Only machines
deployed by this one tech, and all of the machines deployed by this tech,
have this issue. Deleting the HKLM\Software\Novell\Workstation
Manager\InvScanner key (ZEN app to remove key works fine,) setting machines
to do full inventory and re-inventorying fixes things. PitA, but it works.
All machines have the same MAC prefix on the Scan File Name but all get
unique suffix during the process. Is there any documentation on this
"hidden" part of the process?
Erick
"Erick Larson" <[email protected]> wrote in message
news:hRWSf.5072$[email protected]..
>I have a couple hundred imaged machines that all have a MS Loopback Adapter
>in addition to the NIC used for network communication. The MAC address of
>the loopback is always the same. For it's purpose, it is not a problem. For
>whatever reason, ZEN inventory assigns the machines an inventory storer
>string with this MAC number so that each inventory replaces the last. Only
>the last machine inventoried is in the DB. Is there a fix?
>
> Erick Larson
> Perkins Library
> Duke University
> -
How to configure MS Loopback Adapter in Windows 7
Hello all,
I installed SAP NetWeaver 7.02 SP06 ABAP Trial Version mainly to teach myself some
WebDynpro Programming for ABAP. Unfortunately this does not work correctly.
I created a View in a Web Dynpro Component and the Layout Preview does not work.
I activated the services suggested in
http://www.sdn.sap.com/irj/scn/index?rid=/library/uuid/30129979-011c-2e10-fb9b-a60e0d704c1d&overridelayout=true
and did use the report RSICF_SERVICE_ACTIVATION with the variants
WEB DYNPRO ABAP
WEB DYNPRO ABAP DESIGN TIME
WEB DYNPRO ABAP TEST APPS.
In Addition I have set the FQDN as described in the document. I think the problem is the
MS Loopback Adapter. It is displayed with "No connection" in the Network and Sharing Center. I have no idea
how to change this. I have set the IP Adress to the on suggested in the Installation Instructions (10.10.0.10, Subnet-Mask 255.255.255.0) but the Loopback Adapter is displayed with no connection.
If I call a test webdynpro with the Hostname "localhost" it does work, so I think the webserver is running.
Any ideas ?
How do I set up the MS Loopback adapter under Windows 7 correctly ?
Thank you in advance,
AxelHi Axel,
Now that you know your local network works correctly for a computer not connected to internet or intranet, you have to do this:
1- For "No Connection" error (it is not necessary for the sap system to work), it's normal.
Create a local intranet with a 2nd computer if possible and make a configuration for home network after you will see "Connected"
2-Use of Pc hostname
You must configure the "profile parameters" by using transaction RZ10 and activate services (it's not easy, you have to take your time).
3- Webdynpro
To see the result of the webdynpro appli, you may know that not all web browser versions are compatible. The recent browsers don't work, use iexplorer8 or mozilla but not google ==> you will solve the problem of "timeout".
After that:
Activate the "internet communication framework" by using Transaction SICF. It takes you to "Maintain Services" and then fill Hierarchy Type ==>services, execute to reach at this step:
default_host/sap/bc/gui and icf ( If you've installed sap java, you will see both sap and sap_java)
do a mouse right click and select "Activate Service" and choose activate all.
You can now test the sample via web browser by using locahost.
Best regards.
Edited by: Tchounkeu Magloire on Nov 1, 2011 3:48 PM -
Select query problem in JDBC sender adapter
Hello Experts,
We have a problem with PI sender adapter that PI has started to miss records in database some database records are missing and we are using the below selet query :
SELECT * FROM [database name].[dbo].[Material_Movement] WHERE [Process_Order_Number] = (Select TOP 1 [Process_Order_Number] FROM [database name].[dbo].[Material_Movement] WHERE ([PI_Read_Date] IS NULL AND [Movement_Type] = (SELECT TOP 1 [Movement_Type] FROM [database name].[dbo].[Material_Movement] WHERE [Transaction_Code] = 'xyz' AND [PI_Read_Date] IS NULL ORDER BY Created_Date ASC))) AND [Transaction_Code] = 'xyz' AND [Movement_Type] = (SELECT TOP 1 [Movement_Type] FROM [database name].[dbo].[Material_Movement] WHERE [Transaction_Code] = 'xyz' AND [PI_Read_Date] IS NULL ORDER BY Created_Date ASC) AND [PI_Read_Date] IS NULL ORDER BY [Transaction_ID] ASC
I am weak in select query could you please check and suggest how the query can be modified to avoid this issue .
Thanks,
SomenathHi ,
After looking into These Query .. I found ...
Your Query Will run such Kind of scenario ..
1.) Movement Type will be fetched from from below Query
SELECT TOP 1 Movement_Type
FROM database name.dbo.Material_Movement
WHERE Transaction_Code = 'xyz'
AND PI_Read_Date IS NULL
ORDER BY Created_Date ASC
2.) on the basis of abovr fetched moment code . your Query will fetch 1 Process Order number
Select TOP 1 Process_Order_Number
FROM database name.dbo.Material_Movement
WHERE ( PI_Read_Date IS NULL
AND Movement_Type = Moment Type will be same as 1.
3.)
After Getting 1 and 2 . Query will fetch Data from table " dbo.Material_Movement "
On the basis of ..
Movement_Type = value from 1.
Process_order_type = value from 2.
Transaction_Code = 'xyz'
ORDER BY Transaction_ID ASC
So check Missed record Fullfill this Condition or not ....................
If not ... You will get why they are not picked by your given Query ...........
Hope it helps ..
regards
Prabhat Sharma. -
Problem in sender JDBC adapter
hello,
I am facing one typical problem in sender JDBC adapter.
Here is the issue,
JDBC API method getString threw an exception: java.sql.SQLException: Cursor state not valid.
Can anyone please help me out in solving this problem?
Actually after a retry of 3 times the message has been successfully sent. Till then i am getting these error
On 1st attempt ,
Error during conversion of query result to XML java.sql.SQLException: Cursor state not valid
On 2nd attempt,
Error during conversion of query result to XML java.sql.SQLException: Internal driver error
(class.java.lang.InterruptedException)
On 3rd attempt,
Processing finished successfully.
This is the scenario that i can see in the audit log.
Can you please help me out in solving this issue.
Thanks,
SooryaHi gaurav,
It was a good response from your side.
I have gone through the FAQ but could not able to find anything.
Can you please help me out in this regard ?
Also i am using select query of this kind,
SELECT
SEFVHRC.VHRBRCD,SEFVHRC.VHRCUCD,SEFVHRC.VHRVIN,SEFVHRC.VHRMOCD,SEFVHRC.VHRCHAS,
SEFVHRC.VHRSLOR,SEFVHRC.VHRDIVI,SEFVHRC.VHRMGCD,SEFVHRC.VHRMOCH,SEFVHRC.VHRVHTY,
SEFVHRC.VHRBDTY,SEFVHRC.VHRMFYR,SEFVHRC.VHRMOYR,SEFVHRC.VHRMODS,
SEFVHRC.VHRMDTL,SEFVHRC.VHRCLBR,SEFVHRC.VHRRCID,SEFVHRC.VHRARDT,
SEFVHRC.VHRLUTM,SEFVHRC.VHRLUDT,SEFVHRC.VHRKEYN,SEFVHRC.VHRCTORN,
SEFVHRC.VHRCTIMP,SEFVHRC.VHRPRDT,SEFVHRC.VHRPRDT,SEFVHRC.VHRRCDT,
SEFVHFT.VHFCLCD,SEFVHFT.VHFCAT,SEFVHFT.VHFCADSC,SEFVHFT.VHFKEY,SEFVHFT.VHFTEXT1,
SEFVHFT.VHFTEXT2,SEFVHFT.VHFTEXT3,SEFVHFT.VHFTEXT4
FROM
SAPTESTLIB.SEFVHRC,SAPTESTLIB.SEFVHFT
WHERE
SEFVHRC.VHRVIN = SEFVHFT.VHFVIN AND SEFVHRC.VHRSTTS = ' '
and update query of this kind,
Update SEFVHRC SET VHRSTTS = 'R' WHERE VHRSTTS = ' '
I am using prity big select query. is there any option to optimize it?
Can you please help me out in solving this problem
urs,
Soorya -
How to Configure Microsoft loopback adapter in windows 2008
Hi all,
I am trying to install SAP IDES 6.0..... while i m trying to install it , it is asking forUnlimited Strength Jurisdiction Policy Files at runtime.
I do have local and US policy jar file, but i guess its asking for JCE extension file, i dont know about it. so i m not able to proceed
further. it gives osme error about local host. i think its about Microsoft loopback adapter. can anyone have idea abt it.How to
Configure Microsoft loopback adapter in windows 2008?
Can anyone help me ASAP coz i m stucked like anythng.
thanks
CheersHi vinay
Thanks for reply...I m Installing SAP IDES...with DB2
I have upload JCE zip file...after clicking next button i m getting following Errors,
ERROR 2014-10-02 09:52:29
MOS-01185 The subkey 'HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\DPS' does not exist on the 'localhost' host.
ERROR 2014-10-02 09:52:29
FCO-00011 The step collect with step key |NW_Onehost|ind|ind|ind|ind|0|0|NW_Onehost_System|ind|ind|ind|ind|1|0|NW_GetSidNoProfiles|ind|ind|ind|ind|2|0|collect was executed with status ERROR .
i guess its about Loopback adapter configuration. Still i m not sure... DO u have any idea about it.
How i can get rid of it.
Thanks -
Loopback adapter not working - can't install Oracle.
I'm attempting to install 10g on a Win XP box that is not connected to a network. Installation instructions dictate to install the MS loopback adapter before database installation. I installed it, but I can't get the loopback adapter to work. It can't find itself with ping and the 10g software won't install without it.
I'm up for a big job using Oracle and I want to upgrade my skills before I interview. This is very important to me. This may sound a bit corny, but I need to pay for a few medical bills and this job has enough of a pay raise to cover my expenses.
I don't like my current job and I love working with Oracle. Can someone please help me?
-EarlNvm, solved the problem myself using driver genius pro 10
-
Problems with my power adapter!!!!
I just got a new adapter for my Powerbook G4 the other day because the wiring at the plug on my old one wore out. My problem is that the new adapter, when plugged into my computer, sometimes just stops working like it has been unplugged or something. After unplugging the adapter from the wall socket and reinserting, it works fine until my computer goes to sleep. At some point in sleep mode, the little light from the plug in the computer turns off and my computer is only running on battery. This in itself is not that bad, but it gets to be a hassle having to unplug and then re-plug the wall plug everytime my computer goes to sleep. Can anyone help me understand this a little better?
I purchased by G4 six months ago. Since Day one, I have had problems with the power. If I leave the computer plugged into the outlet 24 hours a day, the battery will slowly begin to drain. Even if I never unplug the power source from my computer, the computer begins to drain battery life. For example, I went to bed with my computer charged @ 100%. This morning (all while my computer was sleeping), I have 8% Battery Life left.
I've spent 5-6 phone calls with Apple Care on this issue with no resolution. I sent my G4 off to Apple Care 2 weeks ago and they returned it with a "We Don't Recognize a Problem". I about went through the roof. And, yes, this happens with any outlet I use.
I expect more from a $2500+ machine and their "award winning" customer service.
Help? -
Mac friends
I am facing a problem concerning the creation of loopback adapter.Why do i need a loopback adapter???
Well my intention is to build a network lab on my imac.
The first step is to install GNS3 (Lately available in dmg package).Then we got to upload some router IOS's.So far so goodThe routers work without causing any problem to our powerful machine.
The second step is to install vmWare Fusion,which is a fantastic application to test virtual machines.Now we should install something like OS X Server or Windows Server 2003 or other OS we want to use. I did install Windows XP for network monitoring purposes...
And now the problem....How can i connect my routers to a loopback adapter in case i want to monitor my network through my mac????
Does anybody have an idea about connecting my routers to the virtual interfaces that are created through the OS intallation in vmWare????
Fellows we got excellent machines in our hands and sometimes it makes me angry the fact that i should test somethings in Windows PC's...
Any help will be acceptable....ThnxExcellent test case, may by you should raise an SR and hope it ends up as a bug.
What happens if you "ping box01.data.local" what IP Address do you get back? You should be looking to get back the loopback address.
What happens if you do a nslookup 192.168.30.64 and 192.168.1.100?
Have you tred setting ORACLE_HOSTNAME? Not sure if this is just for the installer or not. -
Problem after SP19 Installation
Hy guys,
ich have the following problem after the SP19 INSTALLATION:
I cannot see the adapter in Adapter Monitor and no communication channel works.
I already read thread about the problem and already imported SAP_BASIS Software components but doesn't work.
Could someone give a tip.
Thank's a lot and a nice day.
Matitype the folllwoing url
http://<yourservrname>:<yourserverport>/mdt/channelmonitorservlet. this is checks whether the adapter is running or not.
Regards
Sreeram.G.Reddy -
Problem with JCA compliant adapter in XI
Hi
I have problem with JCA compliant adapter in XI (SP15).
Adapter works in PCK but doesn't work in XI (periodically).
Sometimes messages delivered with successful status but
very often after send message i have following message in
Message Display Tool (Detail Display):
Engine All
Status System Error
Repeatable Yes
Cancelable Yes
Start 29.03.2006 17:26:57
End 29.03.2006 17:26:57
Quality of Service Exactly Once
Error Category XICACHE
Error Code COMMUNICATIONIncrease the trace level of AFW components to "info" with the Log Configurator J2EE service using VisualAdmin.
When the error happens again, crawl into the most recent DefaultTrace, either by opening the file or by using the more confortable NetWeaver Administrator log viewer (defaulttrace), reachable via browser at http://xiboxhostname:5<sysnr>00/nwa
Good luck.
Alex -
Windows 2008 R2 - Question About Loopback Adapter
Hello,
I have the following situation:
I have two Windows Server 2008 R2 Enterprise with Service Pack 1.
I use a load balancer (Radware Alteon) in DSR mode, to load balance traffic for between these servers.
To use DSR, I have to configure a loopback adapter on each of the, with the IP address of the VIP that is configured on the load balancer.
Everything is working ok, the adapter is recognizing the network and traffic is being loadbalanced perfectly.
The issue starts here:
I also configure a health check on the load balancer, so it can check the health of the server, and stop forwarding traffic to a server when it fails.
One of the failure conditions, is when the loopback adapter fails.
When the physical adapter fails, it is easy to recognize, because the health check, on its basic, is sent to the IP address and MAC address of the physical NIC of the server.
When it is not responding, the server is considered as failed.
However, to recognize a failure of the loopback adapter, the health check is being sent to the IP address of the loopback adapter (that is the VIP) and to the MAC address of the physical NIC.
The load balancer is doing that perfectly and the health checks are passed when the loopback is up.
However, when we simulate a loopback failure, by disabling it, the load balancer does not recognize the failure.
Instead, we just see, in the load balancer statistics, that the server response time is very high (more than 3500000 ms) but the server is up.
The check that we use is a simple ICMP ping request, and we are expecting an ICMP reply withing the specified configured period of time (that is, the timeout).
We started a sniffer catpure on the switch connected to the server.
We saw the following behavior:
When the loopback is disabled, the server still replies to the ICMP requests, but with ICMP redirect (redirect for network)
The ICMP redirect message is sent fromt the source IP address and MAC of the physical NIC.
Then, another ICMP request is sent, and here is also a weird behavior:
The request is sent from the source IP address of the load balancer and source MAC of the server, destination IP address of the loopback adapter (that is the VIP) and destination MAC of the load balancer.
It is clear that this ICMP request is from the same "ICMP session" that was just sent, because it is being sent milliseconds after the first request and ICMP redirect reply. It is not a new health check, because a new health check will be sent after
the interval configured (5 seconds after the first ICMP request).
I don't know if this request is being sent from the server, which means that it spoofs a request from the load balancer by using its IP address as the source, or is it a request being sent from the load balancer, which means it spoofs a request from the server
by using its MAC address as the source.
My question is, if anyone saw such behavior of:
1.) ICMP redirect from the server on Windows 2008 R2 when the loopback is disabled.
2.) A seconds request within the same timeframe of the first request, not a part of a second health check.
I configued the loopback adapter properly, with the weakhostsend and weakhostreceive enabled, and with forwarding enabled (using netsh).
I tested the same topology with Windows Server 2003 Enterprise Edition Service Pack 2.
On this OS, when the loopback is disabled, it just not sending an ICMP reply at all.
Thanking in advance, Udi Dahan.Did you get an answer?
-
Hello,
I need help with configuring MS Loopback Adapter. I am trying to setup Oracle 11g r2 on my Windows 7 Professional laptop which is not connected to any network. There is no virtual network like VMWare either. I followed the instructions in the Oracle release notes but the loopback adapter still says "No Network Access"
The Device Manager for the adapter says, "This device is working properly"
C:\Windows\system32>ipconfig/all
Windows IP Configuration
Host Name . . . . . . . . . . . . : P7One
Primary Dns Suffix . . . . . . . :
Node Type . . . . . . . . . . . . : Hybrid
IP Routing Enabled. . . . . . . . : No
WINS Proxy Enabled. . . . . . . . : No
Ethernet adapter Local Area Connection 2:
Connection-specific DNS Suffix . :
Description . . . . . . . . . . . : Microsoft Loopback Adapter
Physical Address. . . . . . . . . : 02-00-4C-4F-4F-50
DHCP Enabled. . . . . . . . . . . : No
Autoconfiguration Enabled . . . . : Yes
IPv4 Address. . . . . . . . . . . : 10.10.10.10(Preferred)
Subnet Mask . . . . . . . . . . . : 255.255.255.0
Default Gateway . . . . . . . . . :
NetBIOS over Tcpip. . . . . . . . : Disabled
Control Panel>>System shows:
Computer Name: P7One
Full Computer Name: P7One
My laptop is not on any domain. I edited the hosts file as follows:
10.10.10.10 P7One P7One
Network Connections>>Local Area Connection 2
Properties:
I check IPv4 and unchecked everything else.
IPv4 Properties>>Advanced>>WINS
I disabled NetBIOS over TCP/IP <--------- Not sure if this was required.
I disable all other Network connections like Bluetooth and Wireless while trying to use MS Loopback Adapter but the Local Area Connection 2 Status dialog box says:
IPv4 Connectivity: No Network Access
IPv6 Connectivity: No Network Access
Media State: Enabled
Duration: 00:00:00
Speed: 10 Mbps
Activity:
Packets sent: 31. Received:0
Please help me out here. Thank you!DBCA again failed during reinstallation of Oracle with the following error messages:
DIM-00019
OS-1053
ORA-12560
INS-20802
The description of these messages are 3 posts above in this thread.
Updated cmd results after reinstallation:
C:\Windows\system32>ping p7one
Pinging P7One [10.10.10.10] with 32 bytes of data:
Reply from 10.10.10.10: bytes=32 time<1ms TTL=128
Reply from 10.10.10.10: bytes=32 time<1ms TTL=128
Reply from 10.10.10.10: bytes=32 time<1ms TTL=128
Reply from 10.10.10.10: bytes=32 time<1ms TTL=128
Ping statistics for 10.10.10.10:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms
C:\Windows\system32>lsnrctl start
LSNRCTL for 32-bit Windows: Version 11.2.0.1.0 - Production on 21-MAY-2011 13:24
:27
Copyright (c) 1991, 2010, Oracle. All rights reserved.
TNS-01106: Listener using listener name LISTENER has already been started
C:\Windows\system32>lsnrctl status
LSNRCTL for 32-bit Windows: Version 11.2.0.1.0 - Production on 21-MAY-2011 13:24
:46
Copyright (c) 1991, 2010, Oracle. All rights reserved.
Connecting to (DESCRIPTION=(ADDRESS=(PROTOCOL=IPC)(KEY=EXTPROC1521)))
STATUS of the LISTENER
Alias LISTENER
Version TNSLSNR for 32-bit Windows: Version 11.2.0.1.0 - Produ
ction
Start Date 21-MAY-2011 13:18:30
Uptime 0 days 0 hr. 6 min. 19 sec
Trace Level off
Security ON: Local OS Authentication
SNMP OFF
Listener Parameter File D:\app\P7\product\11.2.0\dbhome_1\NETWORK\ADMIN\listen
er.ora
Listener Log File d:\app\p7\diag\tnslsnr\P7One\listener\alert\log.xml
Listening Endpoints Summary...
(DESCRIPTION=(ADDRESS=(PROTOCOL=ipc)(PIPENAME=\\.\pipe\EXTPROC1521ipc)))
(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)(HOST=127.0.0.1)(PORT=1521)))
Services Summary...
Service "CLRExtProc" has 1 instance(s).
Instance "CLRExtProc", status UNKNOWN, has 1 handler(s) for this service...
The command completed successfully
C:\Windows\system32>lsnrctl service
LSNRCTL for 32-bit Windows: Version 11.2.0.1.0 - Production on 21-MAY-2011 13:25
:56
Copyright (c) 1991, 2010, Oracle. All rights reserved.
Connecting to (DESCRIPTION=(ADDRESS=(PROTOCOL=IPC)(KEY=EXTPROC1521)))
Services Summary...
Service "CLRExtProc" has 1 instance(s).
Instance "CLRExtProc", status UNKNOWN, has 1 handler(s) for this service...
Handler(s):
"DEDICATED" established:0 refused:0
LOCAL SERVER
The command completed successfully
C:\Windows\system32>
Please note that it is still not using 10. address.
C:\Windows\system32>sqlplus
SQL*Plus: Release 11.2.0.1.0 Production on Sat May 21 13:34:41 2011
Copyright (c) 1982, 2010, Oracle. All rights reserved.
Enter user-name: / as sysdba
ERROR:
ORA-12560: TNS:protocol adapter error
Enter user-name:
I believe I have not been able to successfully configure MS Loopback Adapter.
In Control Panel >> Network Connections it is still showing:
Local Area Connection 2
Unidentified Network
Microsoft Loopback Adapter
No Network Access
Edited by: 859535 on May 21, 2011 10:40 AM
Maybe you are looking for
-
Hi Gurus, I m working on SRM 7.0, Ehp6, I want to configure MM-SUS scenario. I have activated the Business function LOG_MM_P2PSE_1 and also activated the start event CL_SE_PUR_PO_WF_OUT(Create and Change) for the Workflow WS53800008 in the MM system.
-
Calculating directions (frozen)
Why is it that my program is frozen. I type in an address and click drive to, and then it calculates directions and doesn't move beyond that.
-
MDX Question - roll up to parent value
Hi, I have a relatively simple issue that I am not able to solve. I have the following calculation as a calculated member in my cube: SUM([Territory].[State - City Hierarchy].[City].CurrentMember.Parent, [Measures].[Total Sales]) What I would expect
-
All of a sudden File compatability issues with IPhoto & digital camera
Anyone have issues or solutions for solving file compatability issues with IPhoto & digital camera? Worked okay for years but all of a sudden giving me error messages about file format. My camera uses Jpeg.
-
BAPI to create inbound delivery
Is there any BAPI to create a new inbound delivery without reference to a PO? As far as I know, there is bapi to create outbound deliveries: BAPI_OUTB_DELIVERY_CREATENOREF. Thanks.