Problem idn displaying data in table control

hi
i have searched almost every forum and tried to execute my program but still it is giving problem.
means it does not display the data when i execute the trasanction. it keeps tablecontrol blank.
pls see my code below and give me soloution. plz
In SE51
PROCESS BEFORE OUTPUT.
MODULE STATUS_0100.
loop at itab with control tcb.
module mapdata.
endloop.
PROCESS AFTER INPUT.
MODULE USER_COMMAND_0100.
loop at itab.
endloop.
In SE38
MODULE STATUS_0100 OUTPUT.
SET PF-STATUS 'xxxxxxxx'.
SET TITLEBAR 'xxx'.
select * from zpvcust into table itab.
*read table itab into tcb.
ENDMODULE.                 " STATUS_0100  OUTPUT
*&      Module  mapdata  OUTPUT
      text
MODULE mapdata OUTPUT.
zpvcust-custno = itab-custno.
zpvcust-custname = itab-custname.
ENDMODULE.                 " mapdata  OUTPUT

Hi Vikas
This code you follow the i am sure tou will get the values
process before output.
  module status_0103.
  module get_data.
  loop at   it_bapi3008_2
       into lw_bapi3008_2
       with control tc_data
       cursor tc_data-current_line.
    module tc_data_get_lines.
  endloop.
module getdata output.
  call function 'BAPI_AP_ACC_GETOPENITEMS'
    exporting
      companycode       = 'RS01'
      vendor            = name
      keydate           = ket_data
   noteditems           = 'X'
* IMPORTING
*   RETURN            =
    tables
      lineitems         =  it_bapi3008_2.
  call function 'BAPI_AR_ACC_GETOPENITEMS'
    exporting
      companycode       = 'RS01'
      customer          = lfa1-kunnr
      keydate           = ket_data
*      NOTEDITEMS        = ' '
*      SECINDEX          = ' '
*    IMPORTING
*      RETURN            =
    tables
      lineitems         = it_bapi3007_2.
  loop at it_bapi3007_2 into lw_bapi3007_2.
    lw_bapi3008_2-doc_no = lw_bapi3007_2-doc_no.
    lw_bapi3008_2-doc_date = lw_bapi3007_2-doc_date.
    lw_bapi3008_2-lc_amount = lw_bapi3007_2-lc_amount.
    lw_bapi3008_2-db_cr_ind = lw_bapi3007_2-db_cr_ind.
    lw_bapi3008_2-doc_type  =  lw_bapi3007_2-doc_type.
    lw_bapi3008_2-amt_doccur = lw_bapi3007_2-amt_doccur.
    append lw_bapi3008_2 to it_bapi3008_2.
    clear lw_bapi3008_2.
  endloop.
endmodule.                 " GETDATA  OUTPUT
module tc_data_get_lines output.
  data g_tc_data_lines type sy-loopc.
  g_tc_data_lines = sy-loopc.
endmodule.                    "
try it you will get the values
Regards Nilesh

Similar Messages

  • How to display data in Table control?

    Hi Experts,
    Can anyone please explain me how to display the data from two different tables(those two table is related with 1 field) into a single table control?
    For Example: T1 has fields (F1,F2) and
                         T2 has fields (F3,F4) --> here F3 is foreign key for F1
    I need to display the data F1,F2,F3,F4 into the table control.
    Can anyone explain me?
    Thanks in Advance,
    Regards,
    Raghu

    Hi,
    If F3 is foreign key for F1, then both fields will have same values.  Then why do you need to display both F1 and F3?  Either one of them is enough.  Try the following code.
    types: begin of t_table,
                 F1 type T1-F1,
                 F2 type T1-F2,
                 F4 type T2-F4,
              end of t_table.
    data: i_table type standard table of t_table with header line.
    select F1 F2 F4 into table i_table from T1 inner join T2 on T1F1 = T2F3.
    You should create three columns in the table control with names i_table-F1, i_table-F2, i_table-F3.
    After populating the internal table, refresh the control with the following statement.
    REFRESH CONTROL <NAME> FROM SCREEN <SCREEN_NO>.
    All the above statements should be in your PBO Module.
    Regards,
    Hema
    Message was edited by:
    Sorry, Declarations can be in the common include.  Select statement and refresh statement should be in PBO.
            Hema Nagarajan

  • Problem in displaying data  in table

    Hi all,
    Below is the select statement.Here i am getting values for ls_class_overview-CLASS
    but for ls_class_overview-CLINT.....i am getting 0000000.
    Scenerio : when i select class....i will enter then description(KSCHL) will come and at the same time another table will get display with all characterstics(ATBEZ) and value (AWRT)
    read table lt_class_overview into ls_class_overview index 1.
           select single s~KSCHL
                    into corresponding fields of ls_class_overview
                    from ( SWOR AS s INNER JOIN KLAH AS k
                       ON sCLINT = kCLINT
                      AND k~CLASS = ls_class_overview-CLASS ).
            select single ATBEZ  from CABNT
                    into corresponding fields of ls_class_overview
                    where ATINN = ls_class_overview-CLINT.
             select single ATWRT  from CAWN
                    into corresponding fields of ls_class_overview
                    where ATINN = ls_class_overview-CLINT.
          APPEND  ls_class_overview to lt_class_overview.
    lo_nd_class_overview->bind_table( lt_class_overview )
    Thanks
    Kiran

    I assume when reading table lt_class_overview into the ls you are already getting this as 00000 as in the select you are not populating it. How are you populating the table lt_class_overview?

  • How to modify data in table control

    hi
    i have created table control where i have displayed  data into table control
    logic used
    screen 200
    PROCESS BEFORE OUTPUT.
    MODULE SELECT_RECORD.
    *&SPWIZARD: PBO FLOW LOGIC FOR TABLECONTROL 'TBC_200'
      MODULE TBC_200_CHANGE_TC_ATTR.
    *&SPWIZARD: MODULE TBC_200_CHANGE_COL_ATTR.
      LOOP AT   IT_MARA
           INTO WA_MARA
           WITH CONTROL TBC_200
           CURSOR TBC_200-CURRENT_LINE.
        MODULE TBC_200_GET_LINES.
    *&SPWIZARD:   MODULE TBC_200_CHANGE_FIELD_ATTR
      ENDLOOP.
    MODULE STATUS_0200.
    PROCESS AFTER INPUT.
    *&SPWIZARD: PAI FLOW LOGIC FOR TABLECONTROL 'TBC_200'
      LOOP AT IT_MARA.
        CHAIN.
          FIELD WA_MARA-MATNR.
          FIELD WA_MARA-ERSDA.
          FIELD WA_MARA-ERNAM.
          MODULE TBC_200_MODIFY ON CHAIN-REQUEST.
        ENDCHAIN.
        FIELD WA_MARA-MARK
          MODULE TBC_200_MARK ON REQUEST.
      ENDLOOP.
      MODULE TBC_200_USER_COMMAND.
    *&SPWIZARD: MODULE TBC_200_CHANGE_TC_ATTR.
    *&SPWIZARD: MODULE TBC_200_CHANGE_COL_ATTR.
    module -
    MODULE SELECT_RECORD.
    MODULE SELECT_RECORD OUTPUT.
    SELECT MATNR ERSDA ERNAM
            FROM MARA
            INTO CORRESPONDING FIELDS OF TABLE it_mara.
    ENDMODULE.                 " SELECT_RECORD  OUTPUT
    and
    another thing
    i have made  field  MARA-ERSDA. and  FIELD WA_MARA-ERNAM editable by
    input possible using layout
    so
    now those 2 fields contents  are editable
    i want to know how to edit and save the data
    some body guide.
    and i want to put the lock so that i can update
    can tell how to implement lock.
    Thanks
    Edited by: viju bangalore on Jan 27, 2011 10:40 AM

    Hi Viju,
    In PAI do something like this
    LOOP AT itab.
        MODULE mod_table_control.
    ENDLOOP.
    MODULE user_command_0100.
    at module mod_table_control put this
    MODULE mod_table_control INPUT.
      MODIFY itab FROM demo_conn INDEX flights-current_line.
      if sy-subrc ne 0.
           insert itab.
      endif.
    ENDMODULE.
    for saving you can create at custom gui status with a save button, and at MODULE user_command_0100 save the data.

  • Regarding PAI event display of data in table control

    Hi all,
    I have a drop down list in my module pool screen and based on my selection the value in not getting captured as i have to display table control data (or item level data ) based on the delivery that is selected from the drop down.
    The first level of items are getting displayed in the table control for the first time but after i select the delivery for the next time no delivery is getting captured in the screen field and so on no items are getting changed in the table control.
    Pls let me know how to capture the delivery number selected from the drop down list box and so on i can write the code for displaying the new set of items in the table control for the new delivery number selected.
    Thankyou for your help.
    Amar.

    Hi All,
    I have solved my problum of getting the values in the drop down list using the function module vrm_set_values.
    Earlier it dint capture the values in the list because i am not aware of the key field its having apart from the text field.
    I have passed some numberic value to the key field earlier and the actual text to be displayed in the TEXT field.
    Anyways i came to know that we need to pass the same field values in both key field and text field only then the values wud be captured. So my problum is solved.
    I have another question on the same now
    My requirement is on selecting a value in the dropdown list the delivery items shud come in the dropdown list which is coming.
    I have another drop down in the item level so i wrote the vrm set values in the item level for one field based on that value the other fields in the table control needs to get data.
    I have provided the drop down item level field also but the problum is let us say we have 3 items and in the table control has 15 items that can be displayed. The dropdown for that field shud come only upto 3 records but it is coming for the entire column as the screen field name is same for the entire column.
    example
    f1   f2  f3 are the fields
    and the table control can accomodate 10 records
    Let us say we have 3 line items
    now the drop down is appearing for all the 15 records for field f2 where it shud appear for only  3 records.
    pls let me know if there any option in such a way that we can restrict upto 3 records.
    Thanks in advance.
    Amar.

  • How to populate data in table control  .

    hi all,
    i put matnr no. in screen no. 103
    validation is done at that screen only.
    now when i want to modify dat record
    when i put matnr no. at screen 103
    so how i will get all  data of dat number to table control screen.

    Hi Darshan,
       Here is a detailed description of how to update data in table controll.
      Updating data in table control
    The ABAP language provides two mechanisms for loading the table control with data from the internal table and then storing the altered rows of the table control back to the internal table.
    Method 1: Read the internal table into the Table Control in the screenu2019s flow logic.  Used when the names of the Table Control fields are based on fields of the internal table.
    Method 2: Read the internal table into the Table Control in the module pool code. Used when the names of the Table Control fields are based on fields of the database table.
    Method 1 (table control fields = itab fields)
    In the flow logic we can read an internal table using the LOOP statement. Define the reference to the relevant able control by specifying WITH CONTROL <ctrl>
    Determine which table entry is to be read by specifying CURSOR <ctrl>-CURRENT_LINE.
    After the read operation the field contents are placed in the header line of the internal table. If the fields in the table control have the same name as the internal they will be filled automatically. Otherwise we need to write a module to transfer the internal table fields to the screen fields.
    We must reflect any changes the user makes to the fields of the table control in the internal table otherwise they will not appear when the screen is redisplayed after PBO processing, (eg, after the user presses Enter or scrolls) However, this processing should be performed only if changes have actually been made to the screen fields of the table control (hence the use of the ON REQUEST)
    PROCESS BEFORE OUTPUT.
    LOOP AT ITAB_REG WITH CONTROL TCREG
    CURSOR TCREG-CURRENT_LINE.
    ENDLOOP.
    PROCESS AFTER INPUT.
    LOOP AT ITAB_REG.
    MODULE MODIFY_ITAB_REG.
    ENDLOOP.
    MODULE MODIFY_ITAB_REG INPUT.
    MODIFY ITAB_REG INDEX TCREG-CURRENT_LINE.
    ENDMODULE.
    Method 2 (table control fields = dict. fields)
    If using a LOOP statement without an internal table in the flow logic, we must read the data in a PBO module which is called each time the loop is processed.
    Since, in this case, the system cannot determine the number of internal table entries itself, we must use the EXIT FROM STEP-LOOP statement to ensure that no blank lines are displayed in the table control if there are no more corresponding entries in the internal table.
    PROCESS BEFORE OUTPUT.
    LOOP WITH CONTROL TCREG.
    MODULE READ_ITAB_REG.
    ENDLOOP.
    PROCESS AFTER INPUT.
    LOOP WITH CONTROL TCREG.
    CHAIN.
    FIELD: ITAB_REG-REG,
    ITAB_REG-DESC.
    MODULE MODIFY_ITAB_REG
    ON CHAIN-REQUEST.
    ENDCHAIN.
    ENDLOOP.
    MODULE READ_ITAB_REG OUTPUT.
    READ TABLE ITAB_REG INDEX TCREG-CURRENT_LINE.
    IF SY-SUBRC EQ 0.
    MOVE-CORRESPONDING ITAB_REREG TO TCREG.
    ELSE.
    EXIT FROM STEP-LOOP.
    ENDIF.
    ENDMODULE.
    MODULE MODIFY_ITAB_REG INPUT.
    MOVE-CORRESPONDING TCREG TO ITAB_REG.
    MODIFY ITAB_REG INDEX
    TCREG-CURRENT_LINE.
    ENDMODULE.
    Updating the internal table
    Method 1
    PROCESS AFTER INPUT.
    LOOP AT ITAB_REG.
    CHAIN.
    FIELD: ITAB_REG-REG,
    ITAB_REG-DESC.
    MODULE MODIFY_ITAB_REG ON CHAIN-REQUEST.
    ENDCHAIN.
    ENDLOOP.
    MODULE MODIFY_ITAB_REG INPUT.
    ITAB_REG-MARK = u2018Xu2019.
    MODIFY ITAB_REG INDEX TCREG-CURRENT_LINE.
    ENDMODULE.
    Method 2
    PROCESS AFTER INPUT.
    LOOP WITH CONTROL TCREG.
    CHAIN.
    FIELD: TCREG-REG,
    TCREG-DESC.
    MODULE MODIFY_ITAB_REG ON CHAIN-REQUEST.
    ENDCHAIN.
    ENDLOOP.
    MODULE MODIFY_ITAB_REG INPUT.
    MOVE-CORRESPONDING TCREG TO ITAB_REG.
    ITAB_REG-MARK = u2018Xu2019.
    MODIFY ITAB_REG INDEX TCREG-CURRENT_LINE.
    ENDMODULE.
    Updating the database
    MODULE USER_COMMAND_100.
    CASE OK_CODE.
    WHEN u2018SAVEu2019.
    LOOP AT ITAB-REG.
    CHECK ITAB_REG-MARK = u2018Xu2019.
    MOVE-CORRESPONDING ITAB_REG TO TCREG.
    UPDATE TCREG.
    ENDLOOP.
    WHEN u2026
    u2026
    ENDCASE.
    ENDMODULE.
    Hope this will solve your problem.
    Regards,
    Pavan.
    Edited by: PAVAN CHANDRASEKHAR GANTI on Aug 3, 2009 12:48 PM

  • How to delete data in table control

    Hi,
    I am doing module pool programming. After the user enters the data in table control after saving the data. if the user wants to  remove the line item the line item shd be removed from the screen and data base.
    Please Give me vaulable Suggestions
    Regards

    Hi,
    Screen 8002 (with table control) --> select records --> press delete button --> delete selected records
    Now you wan to delete those records selected by the user at runtime when DELETE button is clicked.
    Take another internal table and work area same as the initial internal table and work area used in screen 8002 which is to be used to delete the selected data.
    Take the names of the input/output fields as work_area-field_name and select column in table control as work_area-flag.
    Also take a flag field of size 1 datatype character as the last field in the internal table and work area while declaration.
    You must have passed a code in PBO of the screen for reading internal table into the table control.
    So it reads the internal table into the table control whenever you perform any action on use command.
    All you need to do is to write a code to modify the internal table form the table control while performing any user action.
    Remember to change the LINE SEL option in attributes of table control as MULTIPLE.
    At screen logic,
    PROCESS BEFORE OUTPUT.
      MODULE status_8002. "for pf-status
      LOOP WITH CONTROL po_tab. "po_tab is table control
        MODULE pass_data. "to pass data into table control from internal table
      ENDLOOP.
    PROCESS AFTER INPUT.
      MODULE user_command_8002. "for user command(back and exit)
      LOOP WITH CONTROL po_tab.
        MODULE modify_data. "to modify data from table control into table control
      ENDLOOP.
      MODULE delete. "to delete the selected records
    In PBO,
    *&      Module  STATUS_8002 OUTPUT
    MODULE status_8002 OUTPUT.
      SET pf-status 'ZAB_PFSTA'. " pf-status
      DATA : line_count TYPE i.
      DESCIRBE TABLE it_ekpo
      LINES line_count.
      po_tab-lines = line_count + 10.
      " to make table control scrollable
    ENDMODULE.                 " STATUS_8002  OUTPUT
    *&      Module  PASS_DATA  OUTPUT
    MODULE pass_data OUTPUT.
      READ TABLE it_ekpo into wa_ekpo INDEX po_tab-current_line.
    ENDMODULE.                 " PASS_DATA  OUTPUT
    "it_ekpo is internal table and wa_ekpo is the work area
    In PAI,
    *&      Module  MODIFY_DATA  INPUT
    MODULE MODIFY_DATA INPUT.
      MODIFY IT_EKPO INDEX PO_TAB-CURRENT_LINE FROM WA_EKPO.
      "modify records from table control into the internal table
    ENDMODULE.                 " MODIFY_DATA  INPUT
    *&      Module  DELETE  INPUT
    MODULE DELETE INPUT.
      OK_CODE = SY-UCOMM.
      CASE OK_CODE.
        WHEN 'DELETE'. "when delete button is clicked
          SORT IT_EKPO BY FLAG DESCENDING. "sort by flag(selection column value)
          CLEAR WA_EKPO1.
          CLEAR WA_EKPO.
          REFRESH IT_EKPO1.
          LOOP AT IT_EKPO INTO WA_EKPO WHERE FLAG = 'X'.
            DATA : J TYPE I.
            CLEAR J.
            J = SY-TABIX. "assign index value if a record is selected
            MOVE-CORRESPONDING WA_EKPO TO WA_EKPO1. "append selected records to another
            "work area and append to another internal table to delete
            APPEND WA_EKPO1 TO IT_EKPO1.
            DELETE IT_EKPO. "delete the selected records from initial internal table
            " to reflect the changes on the table control
          ENDLOOP.
          IF J = 0.
            MESSAGE I006. "if no record selected
          ELSE. "if some records are selected
            DELETE ZEKPO FROM TABLE IT_EKPO1. "delete from database table
            COMMIT WORK.
            IF SY-SUBRC = 0.
              MESSAGE S007. "success message (records deleted)
            ENDIF.
          ENDIF.
      ENDCASE.
    ENDMODULE.                 " DELETE  INPUT
    Now at PAI, you have delete records and these changes are reflected back to the internal table.
    Now when PBO is executed it will again read the initial internal table and will not show the deleted records.
    Hope this solves your problem.
    Thanks & Regards,
    Tarun Gambhir

  • How to clear data in Table Control.

    hi! all
    How to clear the data in table control.
    i have a Table control which displays column A data from the previous screen and allows to enter column B and column C and i have a button CLEAR, when i click CLEAR button the Data displaying in table control has to be cleared. how to do it.
    Regards,
    Nagulan

    Hi,
    Loop over the internal table of table control & clear data from table control.
    loop at tctab.
    clear tctab.
    modify tctab.
    endloop.
    Best regards,
    Prashant

  • How to Populate Internal table data to Table Control in a Report Program

    Dear All,
           How to Populate Internal table data to Table Control in a Report Program? It is a pure report program with out any Module pool coding involved, which is just used to display data. Till now it is being displayed in a report. Now the user wants the data to be displayed in a table control. Could someone tell me how to go about with this.
    Thanks in Advance,
    Joseph Reddy

    If you want to use a table control, you will need to create a screen.
    In your report....
    start-of-selection.
    perform get_data.  " Get all your data here
    call screen 100. " Now present to the user.
    Double click on the "100" in your call screen statement.  This will forward navigate you to the screen.  If you have not created it yet, it will ask you if you want to create it, say yes.  Go into screen painter or layout of the screen.  Use the table control wizard to help you along the process.  It will write the code for you.  Since it is an output only table control, it will be really easy with not a lot of code. 
    A better way to present the data to the user would be to give it in a ALV grid.  If you want to go that way, it is a lot easier.  Here is a sample of the ALV function module.  You don't even have to create a screen.
    report zrich_0004
           no standard page heading.
    type-pools slis.
    data: fieldcat type slis_t_fieldcat_alv.
    data: begin of imara occurs 0,
          matnr type mara-matnr,
          maktx type makt-maktx,
          end of imara.
    * Selection Screen
    selection-screen begin of block b1 with frame title text-001 .
    select-options: s_matnr for imara-matnr .
    selection-screen end of block b1.
    start-of-selection.
      perform get_data.
      perform write_report.
    *  Get_Data
    form get_data.
      select  mara~matnr makt~maktx
                into corresponding fields of table imara
                  from mara
                   inner join makt
                     on mara~matnr = makt~matnr
                        where mara~matnr in s_matnr
                          and makt~spras = sy-langu.
    endform.
    *  WRITE_REPORT
    form write_report.
      perform build_field_catalog.
    * CALL ABAP LIST VIEWER (ALV)
      call function 'REUSE_ALV_GRID_DISPLAY'
           exporting
                it_fieldcat = fieldcat
           tables
                t_outtab    = imara.
    endform.
    * BUILD_FIELD_CATALOG
    form build_field_catalog.
      data: fc_tmp type slis_t_fieldcat_alv with header line.
      clear: fieldcat. refresh: fieldcat.
      clear: fc_tmp.
      fc_tmp-reptext_ddic    = 'Material Number'.
      fc_tmp-fieldname  = 'MATNR'.
      fc_tmp-tabname   = 'IMARA'.
      fc_tmp-outputlen  = '18'.
      fc_tmp-col_pos    = 2.
      append fc_tmp to fieldcat.
      clear: fc_tmp.
      fc_tmp-reptext_ddic    = 'Material'.
      fc_tmp-fieldname  = 'MAKTX'.
      fc_tmp-tabname   = 'IMARA'.
      fc_tmp-outputlen  = '40'.
      fc_tmp-col_pos    = 3.
      append fc_tmp to fieldcat.
    endform.
    Regards,
    Rich Heilman

  • How to show data through table control

    Hi Experts,
    I have created an table control through wizard using table EKKO.
    I have to populate one internal table( type ekko ), and then show it in output  through table control.
    Please advise, how to do that and in where i have to write the codes.
    I will reward points for every suggestion
    Thanks in advance.
    regards

    hi saubrab,
                    This is kiran kumar.G.I am sending some sample code to populate data into table control check it once.
    i will give input in 100 screen. and display table control in 200 screen.check it once once ..ok....
    SE38 :(CODE)
    *& Module pool       YMODULEPOOL_TABLECONTROL1                         *
    *& DEVELOPER   : KIRAN KUMAR.G                                         *
    *& PURPOSE     : TABLE CONTROL DEMO                                    *
    *& CREATION DT : 17/12/2007                                            *
    *& T.CODE      : YMODTABLECONTROL1                                     *
    *& REQUEST     : ERPK900035                                            *
    PROGRAM  ymodulepool_tablecontrol1.
    Tables
    TABLES: yvbap,  "Sales Document: Item Data
            vbak.   "Sales Document: Header Data
    Controls
    CONTROLS: my_table TYPE TABLEVIEW USING SCREEN 200.
    Global Variables
    DATA: gv_lines    TYPE i,
          gv_lines1   type i,
          gv_temp     type i,
          gv_flag(20) TYPE c VALUE 'DISP',
          gv_mode1    TYPE c,
          gv_mode     TYPE c VALUE 'C'. " C: Change, D :Display
    Internal Table
    DATA: BEGIN OF gt_item OCCURS 0,
            vbeln LIKE vbap-vbeln,  "Sales Document Number
            posnr LIKE vbap-posnr,  "Sales Document Item
            matnr LIKE vbap-matnr,  "Material Number
            matkl LIKE vbap-matkl,  "Material Group
            arktx LIKE vbap-arktx,  "Short Text for Sales Order Item
            cflag,                  "Deletion Indicator
          END OF gt_item.
    *&      Module  STATUS_0100  OUTPUT
          text
    MODULE status_0100 OUTPUT.
      SET PF-STATUS 'ZTABLECONTROL' OF PROGRAM 'YMODULEPOOL_TABLECONTROL'.
    SET TITLEBAR 'xxx'.
    ENDMODULE.                 " STATUS_0100  OUTPUT
    *&      Module  USER_COMMAND_0100  INPUT
          text
    MODULE user_command_0100 INPUT.
      CASE sy-ucomm.
        WHEN 'DISP'.
          SELECT single vbeln
                        erdat
                        angdt
                        bnddt
                   FROM vbak
                  INTO (vbak-vbeln,vbak-erdat,
                        vbak-angdt,vbak-bnddt)
                  WHERE vbeln = vbak-vbeln.
            IF sy-subrc EQ 0.
    *Fetch the table control data and place them in Internal Table
              SELECT vbeln
                     posnr
                     matnr
                     matkl
                     arktx
                FROM yvbap
                INTO TABLE gt_item
                WHERE vbeln = vbak-vbeln.
              IF sy-subrc EQ 0.
    *NO OF line in the Internal Table
                DESCRIBE TABLE gt_item LINES gv_lines.
                my_table-lines = gv_lines + 20.
              ENDIF.
            ENDIF.
    *Call Screen 200.
            SET SCREEN 200.
          WHEN  'EXIT' OR 'BACK' OR 'CANCEL'.
    *Exit from the Program
            CALL TRANSACTION 'SESSION_MANAGER'.
        ENDCASE.
      ENDMODULE.                 " USER_COMMAND_0100  INPUT
    module STATUS_0200 output.
    SET PF-STATUS 'ZTABLECONTROL1'.
    endmodule.                 " STATUS_0200  OUTPU
    *&      Module  copy_data  OUTPUT
          text
    module copy_data output.
    *Fetch the current line data from the Table control
    read table gt_item index my_table-current_line.
    if sy-subrc eq 0.
    *Populating data into screen fields
    gt_item-vbeln = gt_item-vbeln.
    gt_item-posnr = gt_item-posnr.
    gt_item-matnr = gt_item-matnr.
    gt_item-matkl = gt_item-matkl.
    gt_item-arktx = gt_item-arktx.
    endif.
    SE51:CODE (SCREEN 100)
    PROCESS BEFORE OUTPUT.
    MODULE STATUS_0100.
    PROCESS AFTER INPUT.
    MODULE USER_COMMAND_0100.
    SE51 :CODE (SCREEN 200)
    PROCESS BEFORE OUTPUT.
    MODULE STATUS_0200.
    loop at gt_item with control my_table cursor my_table-current_line.
    module copy_data.
    endloop.
    PROCESS AFTER INPUT.
    loop at gt_item.
    MODULE USER_COMMAND_0200.
    endloop.
                             HAVE A NICE DAY..
    Award points if helpful,kiran kumar.G

  • Sample pgm for moving data from table control to internal table

    Hi Experts,
          I am newbi to ABAP. I don't have good material for Table control . Appreciate if you direct me to some good source of knowledge on Table control.
    The problem at hand : I am trying to move info/data from table control (in screen painter/ input and output mode ) to ITAB but couldn't . Sample pgm if possible.
    <b>Modify ITAB index TC-Current_Line .</b>
    The above statement is not inserting new lines to ITAB . Help me!
    Thanks for your time

    hi,
    do like this...
    <b>PROCESS AFTER INPUT.</b>
    *&SPWIZARD: PAI FLOW LOGIC FOR TABLECONTROL 'TAB1'
      LOOP AT itab_det.
        CHAIN.
         FIELD itab_det-comp_code.
          FIELD itab_det-bill_no.
          FIELD itab_det-bill_date.
          FIELD itab_det-vend_cust_code.
          FIELD itab_det-bill_amt.
          MODULE <b>tab1_modify</b> ON CHAIN-REQUEST.
        ENDCHAIN.
        FIELD itab_det-mark
          MODULE tab1_mark ON REQUEST.
      ENDLOOP.
    <b>MODULE tab1_modify INPUT.</b>
      APPEND itab_det.
    <b>ENDMODULE.                    "TAB1_MODIFY INPUT</b>

  • How to transfer data in table control in bdc

    hi
    how to transfer data in table control in bdc . I need the theory regarding this
    bye

    Hi,
    just check in the forum , there is many threads available to ur questions.
    Table control in BDC
    http://www.sap-img.com/abap/bdc-example-using-table-control-in-bdc.htm
    You can even refer to these related threads
    bdc table control
    Re: table control in bdc
    table control in BDC
    Reward if helpful.
    Thanks
    Naveen khan

  • How to insert data into table control

    hi experts,,
           i have inserted data into data base table through table control .
    now i want to insert data into table control through database table.
      how to delete data from table control for selected row

    Hi
    go through this link.
    http://www.****************/Tutorials/ABAP/TableControl/Demo.htm

  • Problems with retrieving data from tables with 240 and more records

    Hi,
    I've been connecting to Oracle 11g Server (not sure exact version) using Oracle 10.1.0 Client and O10 Oracle 10g driver. Everything was ok.
    I installed Oracle 11.2.0 Client and I started to have problems with retrieving data from tables.
    First I used the same connection string, driver and so on (O10 Oracle 10g) then I tried ORA Oracle but with no luck. The result is like this:
    I'm able to connect to database. I'm able to retrieve data but from small tables (e.g. with 110 records it works perfectly using both O10 and ORA drivers). When I try to retrieve data from tables with like 240 and more records retrieval simply hangs (nothing happens at all - no error, no timeout). Application seems to hang forever.
    I'm using Powerbuilder to connect to Database (either PB10.5 using O10 driver or PB12 using ORA driver). I used DBTrace, so I see that query hangs on the first FETCH.
    So for the retrievals that hang I have something like:
    (3260008): BIND SELECT OUTPUT BUFFER (DataWindow):(DBI_SELBIND) (0.186 MS / 18978.709 MS)
    (3260008): ,len=160,type=DECIMAL,pbt=4,dbt=0,ct=0,prec=0,scale=0
    (3260008): ,len=160,type=DECIMAL,pbt=4,dbt=0,ct=0,prec=0,scale=1
    (3260008): ,len=160,type=DECIMAL,pbt=4,dbt=0,ct=0,prec=0,scale=0
    (3260008): EXECUTE:(DBI_DW_EXECUTE) (192.982 MS / 19171.691 MS)
    (3260008): FETCH NEXT:(DBI_FETCHNEXT)
    and this is the last line,
    while for retrievals that end, I have FETCH producing time, data in buffer and moving to the next Fetch until all data is retrieved
    On the side note, I have no problems with retrieving data either by SQL Developer or DbVisualizer.
    Problems started when I installed 11.2.0 Client. Even if I want to use 10.0.1 Client, the same problem occurs. So I guess something from 11.2.0 overrides 10.0.1 settings.
    I will appreciate any comments/hints/help.
    Thank you very much.

    pgoel wrote:
    I've been connecting to Oracle 11g Server (not sure exact version) using Oracle 10.1.0 Client and O10 Oracle 10g driver. Everything was ok.Earlier (before installing new stuff) did you ever try retrieving data from big tables (like 240 and more records), if yes, was it working?Yes, with Oracle 10g client (before installing 11g) I was able to retrieve any data, either it was 10k+ records or 100 records. Installing 11g client changed something that even using old 10g client (which I still have installed) fails to work. The same problem occur no matter I'm using 10g or 11g client now. Powerbuilder hangs on retrieving tables with more than like 240 records.
    Thanks.

  • Urgent!!!!!  Inserting data in table control of infotype.

    Hi Experts,
    I want to insert data in custom infotype.I am using FM HR_INFOTYPE_OPERATION for this purpose.But custom infotype contains a table control.
    Table control of infotype has 20 rows containing  fields name01 , addr01 upto name20 , addr20.
    How do i insert data in table control fields of infotype if i want to use FM HR_INFOTYPE_OPERATION .
    Pls suggest if there is another way to do it.
    Thanks.

    Thanks for your reply.
    I am Calling FM HR_INFOTYPE_OPERATION in a loop of a table.
    Table contains multiple employee numbers-PERNR.There can be all different PERNR or some records of same PERNR.
    Suppose if there are four records in the table.First two records are of the same PERNR.Then how would name01 or name02 will be assigned.
    Now, third record is  of new PERNR .Again it should be name01.
    So the question is how everytime in a loop i will assign nameNN for different PERNR.
    nameNN and addrNN was an example. I am sending my code here.
    Loop at it_data.
    gs_9000-PERNR = it_data-pernr..
    gs_9000-currentamount03 = it_data-curramt.
    gs_9000-mtdamount03 = it_data-mtd.
    gs_9000-qtdamount03 = it_data-qtd.
    gs_9000-ytdamount03 = it_data-ytd.
    gs_9000-roll12amount03 = it_data-roll.
    CALL FUNCTION 'BAPI_EMPLOYEE_ENQUEUE'
    EXPORTING
    NUMBER = gs_9000-pernr
    IMPORTING
    RETURN = RETURNE.
    CALL FUNCTION 'HR_INFOTYPE_OPERATION'
    EXPORTING
    INFTY = '9000'
    NUMBER = gs_9000-PERNR
    VALIDITYBEGIN = '20080801' 
    RECORD = gs_9000
    OPERATION = 'INS'
    TCLAS = 'A'
    DIALOG_MODE = '0'
    IMPORTING
    RETURN = RETURN
    KEY = KEY.
    IF RETURN IS NOT INITIAL.
    WRITE :/ 'Error Occurred'.
    ENDIF.
    CALL FUNCTION 'BAPI_EMPLOYEE_DEQUEUE'
    EXPORTING
    NUMBER = gs_9000-PERNR
    endloop.
    So in above code...
    gs_9000-currentamount03 = it_data-curramt.
    gs_9000-mtdamount03 = it_data-mtd.
    gs_9000-qtdamount03 = it_data-qtd.
    gs_9000-ytdamount03 = it_data-ytd.
    gs_9000-roll12amount03 = it_data-roll.
    these are table control fields , so how i wud i assign for
    gs_9000-currentamount04 = it_data-curramt.
    gs_9000-mtdamount04 = it_data-mtd.
    gs_9000-qtdamount04 = it_data-qtd.
    gs_9000-ytdamount04 = it_data-ytd.
    gs_9000-roll12amount04 = it_data-roll.
    in loop of a table.
    Thanks

Maybe you are looking for

  • Automated csv Export from a specific Tab in a Excel Workbook

    Hi, i would like to export a specific tab from an excel workbook on a application server in csv format - how can i do this? Query Extractor doesn´t - about OpenHub i am not shure. thx in advance! cu Dominik

  • Using still images in PP CS6?

    Hi all, newbie to this forum so hello, happy christmas and love to the lot of ya haha   I am trying to make a video for my girlfriends artwork so am using purely still images and text but for the life of me, i cannot get the pics to show at their cor

  • Dynamically ALV  Titles  Using Events - How To

    Dear All, There is a selection screen. Depending upon the selection, there will be output in ALV grid or list. This output doesn't contain any field of selection. So the output must be grouped on the basis of selection as their common title. Eg. If m

  • Legacy serial/parallel

    I am a newbie who just purchased a new Imac G5. Well, not exactly, I had an ancient Performa that we used with our electric piano and a serial MIDI device to help the kids learn. My question is, is there any device that I can reuse the serial MIDI de

  • PLANT NOT AVAILABLE DURING MIGO PURCHASE ORDER

    Hello, When selecting a PO during MIGO