Problem in BW System in Portal..Its urgent.. Please guide

Hello All,
Scenario:
Working in a load balancing landscape
Requirement:
Need to create a BW Report iView (which isnt working)
Problem / Questions:
1. Created a BW System in portal but since its load balancing, please confirm if this is all right:
- Using Logon Tickets Name
- Group = ?group?
- Message Server = ?server?:?port?
- SID = ?r3name?
- Server Port = blank
- SAP Client = blank
- System Type = SAP_BW
- WAS Host = ?server?:?port?
- WAS Protocol = http
- User Mapping Type = admin
2. Tested the connection and the WAS & Connector Tests fail.
3. When I preview the SAP BW Report iView, get a prompt error saying
" session management will not work!
Please check the DSM log file for details.
you can turnoff this alert ..... "
Now, Ive seen many posts which show how can I disable this prompt message but it would not solve the problem. On clicking on "ok" from the above mentioned prompt, I get an error saying "Page cannot be displayed"..
Please guide.....
Its kinda urgent....
Awaiting Reply.
Thanks and Warm Regards,
Ritu

Hi,
Do the following:
<b>1. Property Category : Connector</b>
<b>Group</b> -> You can check this from the SAP Logon Pad. Click on groups and then click on generate list.
<b>Logical System Name</b> -> <SID>CLNT<Client Number>
<b>Message Server</b> -> You can also find the message server from the SAP Logon Pad or ask the BASIS team. On SAP Logon Pad, click on groups -> You can see the servers in the group.
<b>Remote Host Type</b> -> 3
<b>SAP Client</b> -> You can get this from SAP Logon Pad or contact the BASIS team. A system can have many clients to be particular.
<b>SID</b> -> System ID of your BW system. This would also be available from SAP Logon Pad or contact the BASIS team for information
<b>Server Port</b> = The server port would be 80<System Number> i.e. 8000 if the system number is 00 and 8001 if system number is 01
<b>System Type</b> -> SAP_BW
<b>2. Property Category : ITS</b>
<b>ITS Host Name</b> -> If it's WAS6.40 and above, it would be an integrated ITS which means the ITS hostname is same as your BW System Host Name. i.e. xxxx.abc.com:80<system number>
<b>ITS path</b> -> /sap/bc/gui/sap/its/webgui/
<b>ITS Protocol</b> -> http
<b>3. Property Category : User Management</b>
<b>Logon Method</b> -> SAPLOGONTICKET
<b>User Mapping Type</b> -> admin, user
<b>4. Property Category : WAS</b>
<b>WAS Host</b> = Fully Qualified Domain Name of BW System : 80<system number>
<b>WAS Protocol</b> = http
Check the connection then.
Cheers,
Sunil

Similar Messages

  • Hi All,Please send me abap-hr material .Its urgent please.

    Hi All,Please send me abap-hr material .Its urgent please.

    These are the FAQ's that might helps you
    http://www.sap-img.com/human/hr-faq.htm
    http://www.sapgenie.com/faq/hr.htm
    http://www.sapgenie.com/sapfunc/index.htm
    http://www.sap-img.com/abap/sample-hr-reports-allocate-petrol-allowance.htm
    http://www.sap-img.com/hr021.htm
    http://www.sap-img.com/human/hr-faq.htm
    http://www.sap-img.com/human/finding-the-list-of-hr-module-tables.htm
    additional info......
    Download the ABAP e-book for HR in the below link under the section 'Free ABAP eBook Download'
    http://www.sap-img.com
    Also have a look at the following links-
    http://www.sapbrain.com/TUTORIALS/FUNCTIONAL/HR_tutorial.html
    http://www.sapdevelopment.co.uk/hr/hrhome.htm
    http://planetsap.com/index.htm
    http://www.atomhr.com/library_full.htm
    http://www.sap-basis-abap.com/saphr.htm
    http://help.sap.com/saphelp_erp2005/helpdata/en/60/d8d8c7576311d189270000e8322f96/frameset.htm
    http://www.sapfriends.com/sapstuff.html
    http://www.atomhr.com/know_preview/Reading_Payroll_Results_with_ABAP.htm
    http://searchsap.techtarget.com/originalContent/0,289142,sid21_gci1030179,00.html?track=NL-142&ad=500911#Payroll
    http://www.sap-press.com/product.cfm?account=&product=H967
    http://www.sapdevelopment.co.uk/hr/payres_abap.htm
    http://www.sapdevelopment.co.uk/hr/payres_tcode.htm
    http://help.sap.com/printdocu/core/Print46c/en/Data/Index_en.htm
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PAPA/PAPA.pdf
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PAPD/PAPD.pdf
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PYINT/PYINT_BASICS.pdf
    http://www.atomhr.com/training/Technical_Topics_in_HR.htm
    http://www.planetsap.com/hr_abap_main_page.htm
    you can see some Standard Program examples in this one..
    http://www.sapdevelopment.co.uk/programs/programshr.htm
    http://searchsap.techtarget.com/originalContent/0,289142,sid21_gci1030179,00.html?Offer=SAlgwn12604#Certification

  • Its urgent.Please send me the solution.

    Please find me a solution for the specifications.
    Its urgent.
    Please send me the details as early as possible.
    Requirements:
    1.     EDI Invoice requires populating bottle UPC number not case UPC in IDOC and also populates customer PO number when invoice billing type is a credit.  These changes need to be reflected on EDI invoice (Idoc INVOIC02).
    Investigation:
    Requirement 1. EDI invoices are populating segment E1EDP19 qualifier 003 based on the unit of measure in the line item.  If shipment unit is CSE then it populates CSE upc, if shipment unit is EA then it populates Bottle UPC. 
    a.     It was found that the UPC populated on the EDI invoice was being read from material master – Additional data tab.  (Field SMEINH-EAN11).  For the EDI invoice, the customers expect the bottle UPC on this column.
    Requirement 2.  Need to always populate Segment E1EDK02 Qualifier 001 (customer PO) on the INVOIC02 idoc.  Standard SAP populates this information only when the billing type is F2 (regular invoice) and if the customer PO was entered in the Sales Order.
                                a) Premier requires this information to be populated in the idoc if the billing type is G2, RE, L2 also.
    Solution:
    Requirement 1.
           IDOC_OUTPUT_INVOIC function module needs to be changed to always populate the UPC number for the bottle UPC in segment E1EDP19 qualifier 003, field IDTNR.  This number is found on the material master – Basic data 1 view.  Field name is MARA-EAN11.   Please see screenshot of where in the material master to find the bottle UPC. 
         a. This change applies to all billing types (F2, G2, L2, RE etc).
           Requirement 2.
                 Change IDOC_OUTPUT_INVOIC function module to always populate customer PO information in Segment E1EDK02 qualifier 001, field BELNR.
    If billing type is equal to G2, L2, RE and VBRK-XBLNR not equal blanks then make BELNR = VBRK-XBLNR.
    Segment:  E1EDK02
                                  Field:  QUAL = 001
                                  Field:  BELNR = VBRK-XBLNR
    Waiting for your immediate reaction.
    Thanks,
    Chandra.

    Please provide me a solution

  • Problem with abap code in lsmw.its urgent

    Hello guys iam migrating open ar line items using lsmwand i need to create reconciliation key automatically so iam using below code which is working fine in abap editor but i inserted in the lsmw abap code block at step 5 mapping fields iam getting error as that function module does not exits .can any body go through the code and give me suggestion.your will be greatly appreciate.
    types: begin of ty_fikey,
           fikey type fikey_kk,
           resob type resob_kk,
           end of ty_fikey.
    data: wa_fikey type ty_fikey.
    CALL FUNCTION 'FKK_FIKEY_CHECK'
      EXPORTING
        I_FIKEY                      = 'jana56481'
      I_OPEN_ON_REQUEST            =
      I_OPEN_WITHOUT_DIALOG        =
      I_FOR_MASS_POSTING           =
       I_RESOB                      = '24 '
      I_RESKY                      = ' '
      I_NON_EXISTING_ALLOWED       = ' '
      I_FOR_POSTING_IN_UPD         = ' '
    EXCEPTIONS
      NON_EXISTING                 = 1
      OTHERS                       = 2
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    select single  fikey resob from dfkksumc into corresponding fields of wa_fikey where resob = '24'.
    e1bpdfkkko-fikey = wa_fikey-fikey.
    Regards
    Janapathi

    Hi,
    Refer link:
    <a href="http://www.scmexpertonline.com/downloads/SCM_LSMW_StepsOnWeb.doc">http://www.scmexpertonline.com/downloads/SCM_LSMW_StepsOnWeb.doc</a>
    Pls do reward points.
    Regards,
    Ameet

  • Problem while loading applet in opera- very urgent please

    hi,
    I am having problem while loading applet in opera browser. Showing "Applet loading " continuously. I am trying to use URLConnection to read information from applet's own host. I cant find the exact problem what is happening, Since there is no error message in browser Javaconsole.
    If anybody have idea on this please help me. I am in great hurry.
    Thanks in advance.
    Rao. V

    hi this is rao,
    I inserted a lot of System.out statements throughout applet life cycle. But they are not displaying in java console. I think the problem is in Opera-java settings. Since i am new to the opera environment i cant get right solution.
    Please help me if anybody having clear idea on this aspect.
    thanks in advance

  • Its urgent please help me( Drop Down list box)

    Hi i am writing th eBDC for VA32 t-code in that screen it is having the dropdown box for the line items i want to select the drop down list in that screen through BDC how we can do this?
    Thanks in advance

    yes but when we are transfering that value it is not accepting
    0     Assigned by the System (Internal)
    1              Delivery date too late
    2     Poor quality
    3              Too expensive
    4     Competitor better
    5     Guarantee
    10            Unreasonable request
    11     Cust.to receive replacement
    50     Transaction is being checked
    the thing is in the drop downbox these text values are coming
    but how can i?

  • Unable to view HFM System Messages - Very Very Urgent Please.............

    I am having issues with seeing Users on system or system messages in release HFM 11.1.2.1 I get a message that *"You do not have the proper access rights to perform this task."* and I ensured that in the configuration the creator group and administrator group are set up as administrators. I have not been able to find anything that I can change security wise.
    The details of the error are below:
    *" System Messages "*
    You do not have the proper access rights to perform this task.+
    Show Details:
    Error Reference Number: {5F81E0EB-52C5-4C96-8F5A-DD9ECBAE4233}
    Num: 0x8004021d;Type: 0;DTime: 5/9/2011 8:32:22 AM;Svr: GITSHYPT01;File: CHsxServer.cpp;Line: 2457;Ver: 11.1.2.1.000.3082;
    Num: 0x8004021d;Type: 0;DTime: 5/9/2011 8:32:22 AM;Svr: GITSHYPT01;File: CHsxClient.cpp;Line: 4175;Ver: 11.1.2.1.000.3082;
    Num: 0x8004021d;Type: 0;DTime: 5/9/2011 8:32:22 AM;Svr: GITSHYPT01;File: CHFMwManageApplications.cpp;Line: 1060;Ver: 11.1.2.1.000.3082;
    *" Users on System "*
    You do not have the proper access rights to perform this task._
    Show Details:
    Error Reference Number: {1B34A605-F996-4CB9-8D7D-30C0A467170F}
    Num: 0x8004021d;Type: 0;DTime: 5/9/2011 8:33:36 AM;Svr: GITSHYPT01;File: CHsxClient.cpp;Line: 3857;Ver: 11.1.2.1.000.3082;
    Num: 0x8004021d;Type: 0;DTime: 5/9/2011 8:33:36 AM;Svr: GITSHYPT01;File: CHFMwManageApplications.cpp;Line: 1891;Ver: 11.1.2.1.000.3082;
    can anyone please assist....?
    Regards,
    Shan...

    I believe your user ID is not contained within the group set up in the HFM configuration's "application administrator". This group is independent of the role "administrator" since it is set at the server level, not application level. The same group controls access to the enable/disable connnections, and logout users feature.
    --Chris                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   

  • Tv tuner problem!!!!  this is urgent please help....

    Hi,
    I'm trying to capture vidfeo from tv tuner I've done it before with several kinds of tuners
    I'm using " Ati All In Wonder 128 " -display adapter with tv tuner- now and it is giving strange colors on JMF
    studio although it runs fine on Ati software
    any help will be good even any wild guesses will be helpful
    duke

    thanks for your reply
    this problem is fixed now after I captured another format UYVY instead of YUV
    but there is a nother problem if capture with 16 pits per pixel the screen is fine but with 24 a thick black line is at the top of the screen
    the problem is I can change the pits per pixel parameter in jmf studio
    but in my code
    I query the CaptureDeviceManager with a VideoFormat object (it has no way to set the pits per pixel)
    and it is giving the black line
    and when I try to query the CaptureDeviceManager with RGBFormat object to set teh pits per pixel
    It returns a 0 length array of capture device info
    are you familiar with such a problem
    thanks in advance

  • Parameters issue in discoverer while writing a view...its urgent please

    Hi Everybody,
    I have written a view in which i have a where condition which says something like
    where abc IN ( Select xyz from table2).
    Now in my desktop, i want a parameter to pass for the subquery as
    select xyz from table2 where column1='bla bla bla'
    please tell me how is this possbile.
    thank you
    kumar

    Kumar.
    1. Are you trying to show a LOV at run time? If so, you can create a LOV directly in the EUL via Disco Admin which will present a list of the items a user can choose from at run time (and not have to worry about a sub-query).
    2. If it's an actual sub-query you need, then first of all, Disco v4 (maybe it was v9, but that was an ugly child anyway) is the last version that supported 'pseudo' sub-queries.
    3. It's been written up in the forum many times about how to pass run time parameters to a folder in the EUL. There's one method that's popular for actually passing the parm to the folder.
    4. Another method is to create a worksheet that only calls a function, to kick off a PL/SQL routine that builds a table using your parameter and then have the main worksheet call that new table.
    So, if it's a LOV you want - that's a whole lot easier.
    Russ

  • Its urgent please

    Hi,
    Has anyone here had experience with the WAd web application design .Please post me some reagrding this ?
    Thanks in Adv
    Praveen Yagmurthy

    Please search for the documents in SDN. There are also a lot of threads with links to documents on WAD.

  • PLZ ITS URGENT!!!!!!!!!!

    hi i developed a smartforms......
    in it i am using 'SSF_OPEN' and 'SSF_CLOSE' functions to suppress the print preview box which was coming again n again.....
    firstly it was working properly bt i made some changes in my smartforms and then it started giving me the problem n giving the error after executing'Previous Output Request was not finished'...
    plz help me out how to solve this problem....
    PLZ ITS URGENT!!!!!!!!!!!!!!!!!
    plz tell me anyone...........
    Edited by: Pardeep Sharma on Dec 24, 2007 11:38 AM
    Edited by: Pardeep Sharma on Dec 24, 2007 11:57 AM
    Edited by: Pardeep Sharma on Dec 24, 2007 12:12 PM

    Hi,
    Is the requirement to supress the print preview or the dailog box containing the parameters for the print?
    Regards,
    Kk

  • Hi, recently purchased macbook 13", I have problem with sound when connect to my LG Smart tv with sound system. When i change sounds effect on my sound system also LG its all go quiet didn't have this problem with my laptop. Any advise ?

    Hi, recently purchased macbook 13", I have problem with sound when connect to my LG Smart tv with sound system. When i change sounds effect on my sound system also LG its all go quiet didn't have this problem with my laptop. Any advise ?

    Some progess I see. To be honest, i would not waste your time with trying to connect using wireless.
    You are likely to get poor connections and dropping out.
    If its working using a cable, then there is no need to bother with giving me the network settings, bu see how it goes, because sometimes giving the TV a static IP address can give better results.
    There is an example of a couple of powerline adapters on the diagram below. Just ignore the network switch unless you want to connect other devices which are near to the TV.
    http://forumhelp.dyndns.info/networking/powerline3.jpg
    I will monitor the subject line of this thread, should you want to post any more information.
    There are some useful help pages here, for BT Broadband customers only, on my personal website.
    BT Broadband customers - help with broadband, WiFi, networking, e-mail and phones.

  • Process chain problem...., its urgent

    Hi all
    in my process chain we are loading 4 loads into ODS. After 3 loads, 4th load didn't take place. its not yet started even 3rd one successfully ran. its not showing error also. what can i do. after 4th one ODS activation process is there.
    Please advice me. will i go for manual loading. if i do manual, what abt activation after 4th load. will i do activation also manual or else it will trigger automatically as part of process chain........../
    Advice me frnds..., its urgent
    Regards
    swetha

    Hi Swetha,
    Sometimes, it doesn't help to just set a request to green status in order to run the process chain from that step on to the end.
    You need to set the failed request/step to green in the database as well as you need to raise the event that will force the process chain to run to the end from the next request/step on.
    Therefore you need to open the messages of a failed step by right clicking on it and selecting 'display messages'.
    In the opened popup click on the tab 'Chain'.
    In a parallel session goto transaction se16 for table rspcprocesslog and display the entries with the following selections:
    1. copy the variant from the popup to the variante of table rspcprocesslog
    2. copy the instance from the popup to the instance of table rspcprocesslog
    3. copy the start date from the popup to the batchdate of table rspcprocesslog
    Press F8 to display the entries of table rspcprocesslog.
    Now open another session and goto transaction se37. Enter RSPC_PROCESS_FINISH as the name of the function module and run the fm in test mode.
    Now copy the entries of table rspcprocesslog to the input parameters of the function module like described as follows:
    1. rspcprocesslog-log_id -> i_logid
    2. rspcprocesslog-type -> i_type
    3. rspcprocesslog-variante -> i_variant
    4. rspcprocesslog-instance -> i_instance
    5. enter 'G' for parameter i_state (sets the status to green).
    Now press F8 to run the fm.
    Now the actual process will be set to green and the following process in the chain will be started and the chain can run to the end.
    Of course you can also set the state of a specific step in the chain to any other possible value like 'R' = ended with errors, 'F' = finished, 'X' = cancelled ....
    Check out the value help on field rspcprocesslog-state in transaction se16 for the possible values.
    Try this solution with your 3rd ODS..hope this will solve your problem for this instance. This is just a workaround.
    Before next scheduel of the process chain..remove the link between 3rd ODS and 4th ODS and then reconnect once again and activate the process chain and schedule it as per your schedule cycle. From next upload onwards everything works fine.
    Assign points if it is helpful.
    Regards,
    Sreedhar

  • Problem with connecting ipad 2 with crestron cp2e...help plss its urgent... I hv a ipad 2 with mobile pro g connected with cp2e. when i pressed any button in ipad its connet with cp2e but after 4-5 sec one error comes (warning wifi was powered off while t

    problem with connecting ipad 2 with crestron cp2e...help plss its urgent...
    I hv a ipad 2 with mobile pro g connected with cp2e. when i pressed any button in ipad its connet with cp2e but after 4-5 sec one error comes (warning wifi was powered off while the device was in auto -lock(sleep)press connect to reconnect) when i pressed again its connected with cp2e. i am using netgear wireless access point . i also has been changed access point as well as updated ipad firmware bt problem is as it is .. pls help.

    Hi have you solved the issue ?
    Cause I have the same problem.
    Tnx

  • Remedy system to Portal - HTTPS problem

    Hello folks,
        I am integrating remedy system to portal using R/3. We are not able to consume the webservice directly from the Iview using portal services(not supporting for the remedy system). So we have created a RFM(using SOAP). Portal connects to R/3 using this RFM and R/3 connects to remedy system and returns the ticket created which is passed to the portal.
       This works fine if the webservice is HTTP based but doesn't work after enabling HTTPS. Keeps giving authentiocation/HTTP communication err. Does the webservice supports HTTPS using ABAP?.They do have an option to accept HTTPS but it's not working.(Scheme 1= HTTP , 2 = HTTPS )
    call method cl_http_client=>create
    exporting
    host = 'arsdev'
    service = '8883'
    scheme = '2'
    importing
    client = http_client.
    Has anyone encountered the same problem ? Is there anyway we can consume the webservice thru' ABAP after enabling HTTPS?
    Thanks,
    Vikram

    Hi, gurus.
    I thought you have successfully configured Solman-BMC connection before?
    Can you share some thoughts on it, especially where I can found decent documentation that tells step I should take. I've configured it for days, but I can't understand how Solman will pass message to Remedy and vice versa.
    Do you have email or messenger so I can ask about it?
    I've followed SAP guidances from service marketplace and here http://tknight.org/sdn/show/9985 but with no luck.
    Thanks gurus.

Maybe you are looking for

  • Change book size after design?

    Is there any way to do this?  I've created a book in Extra Large, then looked at the price and though, "maybe a smaller size would be OK, and cheaper." But I can't seem to find a way to change the book size.  Is this not possible?  Do I have to redo

  • New Inkjet Printer Recommendations?

    My little trusty HP 932c (from the stone age) has finally given up the ghost. I'm interested in getting something in the $200ish range to replace it, though I would consider going higher if features would warrant the additional cost. I've only just s

  • Need a help regarding planning layout

    Hi, I am designing a planning layout in OPO1. I have defined a column for Cost Eelemnt and next four columns with Period and Fiscal years, for these each column in the header line, i typed "&$1". Also created a Total Forecasted column for the sum of

  • Ahhhhh... change the description for "Reset printing system"!!!!!!!!!!

    It reads exactly like this: "Are you sure you want to reset the printing system? This will delete all of your existing printer queues and all pending print jobs." Who would expect this will delete all the installed printers?? Apple should really chan

  • Quest: using ClamAV - Setting

    Hi at all, have a short quest, what is the right setting for ClamV for Mac? and is .. ClamAV good for Snow Leopard protection? Sorry for poor and simply english Thanks a lot