Problem in syntax :- LEAVE TO SCREEN 0

Hi Experts,
I created a main program in se38.
I called a screen 100(that is module pool program).
in that i called dialog box. If i press ok in the dialog box i should come to screen 100
but it is gooing to screen 1000 that is main program.
Syntax i writen in dialog box is LEAVE TO SCREEN 0.
plz reply as soon as possible.

Hi,
You should use CALL SCREEN '0100'.  It will take you to 100 screen.
or
You can use LEAVE TO SCREEN '0100'. It will LEAVE the current screen and take you to the screen 100.
With Regards,
Rupinder

Similar Messages

  • Error in Leave Request screen

    Hi All,
    Particular group of employess are facing problem in accessing leave request screen in the portal. They are getting the following error.
    *********Error**************
    "There are no customizing settings for absence type".
    Please guide me in resolving this.
    Thanks,
    Steffler.

    Hi,
    Can you check if the absence is correctly maintained, also make sure absence which were available earlier are customised correctly and not delimited or removed.
    Check t-code "PTARQ" .
    Hope the tasks are set to "General Task"
    SPRO> Time Management>Web Application>Leave Request(new)>Link Absence types and workflow templates.
    Regards
    Puneet

  • ALV Leave to screen problem

    Dear Friends,
    i have interactive ALV so their flow as follows
    1. When i execute the program Load ALV (i named it ALV1)
    2. When  double click - another ALV displayed (I named it as ALV2)
    3. In the ALV2, there is a button to add data (suppose there are two records)
    4. When click on Add button, Screen is appear to enter data and also there is a Save button
    5. When click on the save button, data saved to Table and ALV2 refreshed (now there are three records)
    6. When I click on the Back button (tools) its come to ALV2 previous position (ALV2 with two records)
    my problem is, when click on the BACK button it must comes to ALV1
    not to ALV2 previous position
    how can i code this in the back button.
    I already used LEAVE TO SCREEN 0
    I hope, you will clear my doubt
    Thanks in Advanced

    HI,
    In the PAI of second screen(where you display ALV2)
    IF Sy-ucomm EQ 'SAVE'.
    " If you are calling the second screen using the call screen <second screen>
    " then replace this with these statements
    SET SCREEN <>second_screen>.
    LEAVE SCREEN
    ENDIF

  • Problems by holding the typed Values in Fields by using "LEAVE TO SCREEN"

    Hello Experts,
    I have created a Dynpro  with many field.
    Some Fields are Fields without searchhelps and a part of this Fields have searchhelps.
    One of this Field has a special function.
    It is a Field where you can choose a key value ( an ID number) about the searchhelp.
    After choosing I get the other values for this ID-Number in the returnparameter of the Searchhelp function
    ( values like name, surname ....)
    I set this return values  to the Fieldvariables in the PBO.
    For jumping to PBO I use "Leave to Screen" to the same screen.
    But the Problem is I can not hold the values wich I have typed before  in the Dynpro Fields (Field without serachhelps).
    After using the Field with the Searchhelp (for ID)  the Fields with typed Value go away.
    Please Hel me . Thanx in Advance
    Cetin

    Hi,
    In SE80 double click on your Screen Number and go to the Attributes Tab and Select Hold Data Check box,
    The Help Obtained from F1 Help is as follows, Kindly note this is Copied from F1 Help provided by Standard SAP,
    You too can Check it out
    "SAP Says --->
    If you activate this option, the following functions are supported for
    the screen at runtime:
    System -> User profile -> Hold data
                            -> Set data
                            -> Delete data
    The Hold data function allows you to hold onto any entries you have made
    on the screen. When the screen is next processed (even in a different
    mode), the system then automatically redisplays the data in the input
    fields.
    If the option is not activated, these functions are ineffective at
    screen runtime.
    The "Hold Data" option is not supported for include screens
    (subscreens). The automatic insertion of held data is exclusively
    controlled by the main screen.
    Cheerz
    Ram

  • Leave to screen 0 does not branch to initialization event (ALV)

    Hi All,
    I'm new at this forum thing so be gentle. I have created the standard custom control in a new screen, setup the field catalog and other parameters and when I call the screen and do the :
      IF g_custom_container IS INITIAL.
        CREATE OBJECT g_custom_container
           EXPORTING
              container_name = 'ZTMR_EVAL_GRID'.
        CREATE OBJECT g_grid
           EXPORTING
             i_parent = g_custom_container.
        CLEAR wa_disvariant.
        wa_disvariant-report = sy-repid.
        CALL METHOD g_grid->set_table_for_first_display
          EXPORTING
            is_variant      = wa_disvariant
            i_save          = 'A'
            is_layout       = wa_layout
          CHANGING
            it_outtab       = detail_tab[]
            it_fieldcatalog = itab_fldcat
            it_sort         = itab_sort.
        CREATE OBJECT event_receiver.
        SET HANDLER event_receiver->handle_top_of_page FOR g_grid.
      ENDIF.
    , everything works great. The problem occurs when hit the BACK button in my PAI module, it returns to the line after the CALL SCREEN XXX, ENDFORM, PERFORM output_alv_grid_report and then branches to :
    FUNCTION hrpy_process_fire_event in the source code of LHRST1U01 in the main program SAPLHRST1.
    It does this instead of branching to the INITIALIZATION event (selection-screen) which is what it's supposed to do?
    Any help would be greatly appreciated - Thanks in advance,
    Jim

    hi,
    REPORT  ZTEST1234_ALV_TOP    MESSAGE-ID ZZ                           .
    DATA: G_GRID TYPE REF TO CL_GUI_ALV_GRID.
    DATA: L_VALID TYPE C,
          V_FLAG,
          V_DATA_CHANGE,
          V_ROW TYPE LVC_S_ROW,
          V_COLUMN TYPE LVC_S_COL,
          V_ROW_NUM TYPE LVC_S_ROID.
    "The Below Definitions Must.....
    DATA:
    * Reference to document
           DG_DYNDOC_ID       TYPE REF TO CL_DD_DOCUMENT,
    * Reference to split container
           DG_SPLITTER          TYPE REF TO CL_GUI_SPLITTER_CONTAINER,
    * Reference to grid container
           DG_PARENT_GRID     TYPE REF TO CL_GUI_CONTAINER,
    * Reference to html container
           DG_HTML_CNTRL        TYPE REF TO CL_GUI_HTML_VIEWER,
    * Reference to html container
           DG_PARENT_HTML     TYPE REF TO CL_GUI_CONTAINER.
    "up to here
    *       CLASS lcl_event_handler DEFINITION
    CLASS LCL_EVENT_HANDLER DEFINITION .
      PUBLIC SECTION .
        METHODS:
    **Hot spot Handler
        HANDLE_HOTSPOT_CLICK FOR EVENT HOTSPOT_CLICK OF CL_GUI_ALV_GRID
                          IMPORTING E_ROW_ID E_COLUMN_ID ES_ROW_NO,
    **Double Click Handler
        HANDLE_DOUBLE_CLICK FOR EVENT DOUBLE_CLICK OF CL_GUI_ALV_GRID
                                         IMPORTING E_ROW E_COLUMN ES_ROW_NO,
        TOP_OF_PAGE FOR EVENT TOP_OF_PAGE              "event handler
                             OF CL_GUI_ALV_GRID
                             IMPORTING E_DYNDOC_ID.
    ENDCLASS.                    "lcl_event_handler DEFINITION
    *       CLASS lcl_event_handler IMPLEMENTATION
    CLASS LCL_EVENT_HANDLER IMPLEMENTATION.
    *Handle Hotspot Click
      METHOD HANDLE_HOTSPOT_CLICK .
        CLEAR: V_ROW,V_COLUMN,V_ROW_NUM.
        V_ROW  = E_ROW_ID.
        V_COLUMN = E_COLUMN_ID.
        V_ROW_NUM = ES_ROW_NO.
        MESSAGE I000 WITH V_ROW 'clicked'.
      ENDMETHOD.                    "lcl_event_handler
    *Handle Double Click
      METHOD  HANDLE_DOUBLE_CLICK.
      ENDMETHOD.                    "handle_double_click
      METHOD TOP_OF_PAGE.                   "implementation
    * Top-of-page event
        PERFORM EVENT_TOP_OF_PAGE USING DG_DYNDOC_ID.
      ENDMETHOD.                            "top_of_page
    ENDCLASS.                    "LCL_EVENT_HANDLER IMPLEMENTATION
    *&             Global Definitions
    DATA:      G_CUSTOM_CONTAINER TYPE REF TO CL_GUI_CUSTOM_CONTAINER,"Container1
                G_HANDLER TYPE REF TO LCL_EVENT_HANDLER. "handler
    DATA: OK_CODE LIKE SY-UCOMM,
          SAVE_OK LIKE SY-UCOMM,
          G_CONTAINER1 TYPE SCRFNAME VALUE 'TEST',
          GS_LAYOUT TYPE LVC_S_LAYO.
    *- Fieldcatalog for First and second Report
    DATA: IT_FIELDCAT  TYPE  LVC_T_FCAT,
          X_FIELDCAT TYPE LVC_S_FCAT,
          LS_VARI  TYPE DISVARIANT.
    *                START-OF_SELECTION
    START-OF-SELECTION.
      DATA:BEGIN OF  ITAB OCCURS 0,
           VBELN LIKE LIKP-VBELN,
           POSNR LIKE LIPS-POSNR,
           CELLCOLOR TYPE LVC_T_SCOL, "required for color
           DROP(10),
           END OF ITAB.
      SELECT VBELN
             POSNR
             FROM LIPS
             UP TO 20 ROWS
             INTO CORRESPONDING FIELDS OF TABLE ITAB.
    END-OF-SELECTION.
      IF NOT ITAB[] IS INITIAL.
        <b>CALL SCREEN 100.</b>
      ELSE.
        MESSAGE I002 WITH 'NO DATA FOR THE SELECTION'(004).
      ENDIF.
    *&      Form  CREATE_AND_INIT_ALV
    *       text
    FORM CREATE_AND_INIT_ALV .
      DATA: LT_EXCLUDE TYPE UI_FUNCTIONS.
      "attention.....from here
      "split your container here...into two parts
      "create the container
      CREATE OBJECT G_CUSTOM_CONTAINER
               EXPORTING CONTAINER_NAME = G_CONTAINER1.
      "this is for top of page
    * Create TOP-Document
      CREATE OBJECT DG_DYNDOC_ID
                       EXPORTING STYLE = 'ALV_GRID'.
    * Create Splitter for custom_container
      CREATE OBJECT DG_SPLITTER
                 EXPORTING PARENT  = G_CUSTOM_CONTAINER
                           ROWS    = 2
                           COLUMNS = 1.
    * Split the custom_container to two containers and move the reference
    * to receiving containers g_parent_html and g_parent_grid
      "i am allocating the space for grid and top of page
      CALL METHOD DG_SPLITTER->GET_CONTAINER
        EXPORTING
          ROW       = 1
          COLUMN    = 1
        RECEIVING
          CONTAINER = DG_PARENT_HTML.
      CALL METHOD DG_SPLITTER->GET_CONTAINER
        EXPORTING
          ROW       = 2
          COLUMN    = 1
        RECEIVING
          CONTAINER = DG_PARENT_GRID.
      "you can set the height of it
    * Set height for g_parent_html
      CALL METHOD DG_SPLITTER->SET_ROW_HEIGHT
        EXPORTING
          ID     = 1
          HEIGHT = 5.
      "from here as usual..you need to specify parent as splitter part
      "which we alloted for grid
      CREATE OBJECT G_GRID
             EXPORTING I_PARENT = DG_PARENT_GRID.
    * Set a titlebar for the grid control
      CLEAR GS_LAYOUT.
      GS_LAYOUT-GRID_TITLE = TEXT-003.
      GS_LAYOUT-ZEBRA = SPACE.
      GS_LAYOUT-CWIDTH_OPT = 'X'.
      GS_LAYOUT-NO_ROWMARK = 'X'.
      GS_LAYOUT-CTAB_FNAME = 'CELLCOLOR'.
      CALL METHOD G_GRID->REGISTER_EDIT_EVENT
        EXPORTING
          I_EVENT_ID = CL_GUI_ALV_GRID=>MC_EVT_ENTER.
      CREATE OBJECT G_HANDLER.
      SET HANDLER G_HANDLER->HANDLE_DOUBLE_CLICK FOR G_GRID.
      SET HANDLER G_HANDLER->HANDLE_HOTSPOT_CLICK FOR G_GRID.
      SET HANDLER G_HANDLER->TOP_OF_PAGE FOR G_GRID.
      DATA: LS_CELLCOLOR TYPE LVC_S_SCOL. "required for color
      DATA: L_INDEX TYPE SY-TABIX.
      "Here i am changing the color of line 1,5,10...
      "so you can change the color of font conditionally
      LOOP AT ITAB.
        L_INDEX = SY-TABIX.
        IF L_INDEX = 1 OR L_INDEX = 5 OR L_INDEX = 10.
          LS_CELLCOLOR-FNAME = 'VBELN'.
          LS_CELLCOLOR-COLOR-COL = '6'.
          LS_CELLCOLOR-COLOR-INT = '0'.
          LS_CELLCOLOR-COLOR-INV = '1'.
          APPEND LS_CELLCOLOR TO ITAB-CELLCOLOR.
          MODIFY ITAB INDEX L_INDEX TRANSPORTING CELLCOLOR.
          LS_CELLCOLOR-FNAME = 'POSNR'.
          LS_CELLCOLOR-COLOR-COL = '6'.
          LS_CELLCOLOR-COLOR-INT = '0'.
          LS_CELLCOLOR-COLOR-INV = '1'.
          APPEND LS_CELLCOLOR TO ITAB-CELLCOLOR.
          MODIFY ITAB INDEX L_INDEX TRANSPORTING CELLCOLOR.
        ENDIF.
      ENDLOOP.
    * setting focus for created grid control
      CALL METHOD CL_GUI_CONTROL=>SET_FOCUS
        EXPORTING
          CONTROL = G_GRID.
    * Build fieldcat and set editable for date and reason code
    * edit enabled. Assign a handle for the dropdown listbox.
      PERFORM BUILD_FIELDCAT.
      PERFORM  SET_DRDN_TABLE.
    * Optionally restrict generic functions to 'change only'.
    *   (The user shall not be able to add new lines).
      PERFORM EXCLUDE_TB_FUNCTIONS CHANGING LT_EXCLUDE.
    **Vaiant to save the layout
      LS_VARI-REPORT      = SY-REPID.
      LS_VARI-HANDLE      = SPACE.
      LS_VARI-LOG_GROUP   = SPACE.
      LS_VARI-USERNAME    = SPACE.
      LS_VARI-VARIANT     = SPACE.
      LS_VARI-TEXT        = SPACE.
      LS_VARI-DEPENDVARS  = SPACE.
    **Calling the Method for ALV output
      CALL METHOD G_GRID->SET_TABLE_FOR_FIRST_DISPLAY
        EXPORTING
          IT_TOOLBAR_EXCLUDING = LT_EXCLUDE
          IS_VARIANT           = LS_VARI
          IS_LAYOUT            = GS_LAYOUT
          I_SAVE               = 'A'
        CHANGING
          IT_FIELDCATALOG      = IT_FIELDCAT
          IT_OUTTAB            = ITAB[].
      "do these..{
    * Initializing document
      CALL METHOD DG_DYNDOC_ID->INITIALIZE_DOCUMENT.
    * Processing events
      CALL METHOD G_GRID->LIST_PROCESSING_EVENTS
        EXPORTING
          I_EVENT_NAME = 'TOP_OF_PAGE'
          I_DYNDOC_ID  = DG_DYNDOC_ID.
      "end }
    * Set editable cells to ready for input initially
      CALL METHOD G_GRID->SET_READY_FOR_INPUT
        EXPORTING
          I_READY_FOR_INPUT = 1.
    ENDFORM.                               "CREATE_AND_INIT_ALV
    *&      Form  EXCLUDE_TB_FUNCTIONS
    *       text
    *      -->PT_EXCLUDE text
    FORM EXCLUDE_TB_FUNCTIONS CHANGING PT_EXCLUDE TYPE UI_FUNCTIONS.
    * Only allow to change data not to create new entries (exclude
    * generic functions).
      DATA LS_EXCLUDE TYPE UI_FUNC.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_COPY_ROW.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_DELETE_ROW.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_APPEND_ROW.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_INSERT_ROW.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_MOVE_ROW.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_COPY.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_CUT.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_PASTE.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_PASTE_NEW_ROW.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
      LS_EXCLUDE = CL_GUI_ALV_GRID=>MC_FC_LOC_UNDO.
      APPEND LS_EXCLUDE TO PT_EXCLUDE.
    ENDFORM.                               " EXCLUDE_TB_FUNCTIONS
    *&      Form  build_fieldcat
    *       Fieldcatalog
    FORM BUILD_FIELDCAT .
      DATA: L_POS TYPE I.
      L_POS = L_POS + 1.
      X_FIELDCAT-SCRTEXT_M = 'Delivery'(024).
      X_FIELDCAT-FIELDNAME = 'VBELN'.
      X_FIELDCAT-TABNAME = 'IT_FINAL'.
      X_FIELDCAT-COL_POS    = L_POS.
      X_FIELDCAT-NO_ZERO    = 'X'.
      X_FIELDCAT-OUTPUTLEN = '10'.
      X_FIELDCAT-HOTSPOT = 'X'.
      APPEND X_FIELDCAT TO IT_FIELDCAT.
      CLEAR X_FIELDCAT.
      L_POS = L_POS + 1.
      X_FIELDCAT-SCRTEXT_M = 'Item'(025).
      X_FIELDCAT-FIELDNAME = 'POSNR'.
      X_FIELDCAT-TABNAME = 'IT_FINAL'.
      X_FIELDCAT-COL_POS    = L_POS.
      X_FIELDCAT-OUTPUTLEN = '5'.
      APPEND X_FIELDCAT TO IT_FIELDCAT.
      CLEAR X_FIELDCAT.
      L_POS = L_POS + 1.
      X_FIELDCAT-SCRTEXT_M = 'Drop'(025).
      X_FIELDCAT-FIELDNAME = 'DROP'.
      X_FIELDCAT-TABNAME = 'IT_FINAL'.
      X_FIELDCAT-COL_POS    = L_POS.
      X_FIELDCAT-OUTPUTLEN = '5'.
      X_FIELDCAT-EDIT = 'X'.
      X_FIELDCAT-DRDN_HNDL = '1'.
      X_FIELDCAT-DRDN_ALIAS = 'X'.
      APPEND X_FIELDCAT TO IT_FIELDCAT.
      CLEAR X_FIELDCAT.
    ENDFORM.                    " build_fieldcat
    *&      Module  STATUS_0100  OUTPUT
    *       text
    MODULE STATUS_0100 OUTPUT.
      SET PF-STATUS 'MAIN100'.
      SET TITLEBAR 'MAIN100'.
      IF G_CUSTOM_CONTAINER IS INITIAL.
    **Initializing the grid and calling the fm to Display the O/P
        PERFORM CREATE_AND_INIT_ALV.
      ENDIF.
    ENDMODULE.                 " STATUS_0100  OUTPUT
    *&      Module  USER_COMMAND_0100  INPUT
    *       text
    MODULE USER_COMMAND_0100 INPUT.
      CASE SY-UCOMM.
        WHEN 'BACK'.
          LEAVE TO SCREEN 0.
      ENDCASE.
    ENDMODULE.                 " USER_COMMAND_0100  INPUT
    *&      Form  SET_DRDN_TABLE
    *       text
    FORM SET_DRDN_TABLE.
      DATA:LT_DRAL TYPE LVC_T_DRAL,
            LS_DRAL TYPE LVC_S_DRAL.
      LOOP AT ITAB .
    * First listbox (handle '1').
        IF SY-INDEX = 1.
          LS_DRAL-HANDLE = '1'.
          LS_DRAL-VALUE =  ' '.
          LS_DRAL-INT_VALUE =  ' '.
        ELSE.
          LS_DRAL-HANDLE = '1'.
          LS_DRAL-VALUE =  ITAB-POSNR.
          LS_DRAL-INT_VALUE =  ITAB-POSNR.
        ENDIF.
        APPEND LS_DRAL TO LT_DRAL.
      ENDLOOP.
    **Setting the Drop down table for Reason Code
      CALL METHOD G_GRID->SET_DROP_DOWN_TABLE
        EXPORTING
          IT_DROP_DOWN_ALIAS = LT_DRAL.
    ENDFORM.                               " set_drdn_table
    *&      Form  EVENT_TOP_OF_PAGE
    *       text
    *      -->DG_DYNDOC_ID  text
    FORM EVENT_TOP_OF_PAGE USING   DG_DYNDOC_ID TYPE REF TO CL_DD_DOCUMENT.
      "this is more clear.....check it
      "first add text, then pass it to comentry write fm
      DATA : DL_TEXT(255) TYPE C.  "Text
    * Populating header to top-of-page
      CALL METHOD DG_DYNDOC_ID->ADD_TEXT
        EXPORTING
          TEXT      = 'Test Report'
          SAP_STYLE = CL_DD_AREA=>HEADING.
    * Add new-line
      CALL METHOD DG_DYNDOC_ID->NEW_LINE.
      CLEAR : DL_TEXT.
    * Move program ID
      CONCATENATE 'Program Name :' SY-REPID
             INTO DL_TEXT SEPARATED BY SPACE.
    * Add Program Name to Document
      PERFORM ADD_TEXT USING DL_TEXT.
    * Add new-line
      CALL METHOD DG_DYNDOC_ID->NEW_LINE.
      CLEAR : DL_TEXT.
    * Move User ID
      CONCATENATE 'User ID :' SY-UNAME INTO DL_TEXT SEPARATED BY SPACE
    * Add User ID to Document
      PERFORM ADD_TEXT USING DL_TEXT.
    * Add new-line
      CALL METHOD DG_DYNDOC_ID->NEW_LINE.
      CLEAR : DL_TEXT.
    * Move Client
      CONCATENATE 'Client :' SY-MANDT INTO DL_TEXT SEPARATED BY SPACE.
    * Add Client to Document
      PERFORM ADD_TEXT USING DL_TEXT.
    * Add new-line
      CALL METHOD DG_DYNDOC_ID->NEW_LINE.
      CLEAR : DL_TEXT.
    * Move date
      WRITE SY-DATUM TO DL_TEXT.
      CONCATENATE 'Date :' DL_TEXT INTO DL_TEXT SEPARATED BY SPACE.
    * Add Date to Document
      PERFORM ADD_TEXT USING DL_TEXT.
    * Add new-line
      CALL METHOD DG_DYNDOC_ID->NEW_LINE.
      CLEAR : DL_TEXT.
    * Move time
      WRITE SY-UZEIT TO DL_TEXT.
      CONCATENATE 'Time :' DL_TEXT INTO DL_TEXT SEPARATED BY SPACE.
    * Add Time to Document
      PERFORM ADD_TEXT USING DL_TEXT.
    * Add new-line
      CALL METHOD DG_DYNDOC_ID->NEW_LINE.
    * Populating data to html control
      PERFORM HTML.
    ENDFORM.                    " EVENT_TOP_OF_PAGE
    *&      Form  ADD_TEXT
    *       To add Text
    FORM ADD_TEXT USING P_TEXT TYPE SDYDO_TEXT_ELEMENT.
    * Adding text
      CALL METHOD DG_DYNDOC_ID->ADD_TEXT
        EXPORTING
          TEXT         = P_TEXT
          SAP_EMPHASIS = CL_DD_AREA=>HEADING.
    ENDFORM.                    " ADD_TEXT
    *&      Form  HTML
    *       text
    FORM HTML.
      DATA : DL_LENGTH  TYPE I,                           " Length
             DL_BACKGROUND_ID TYPE SDYDO_KEY VALUE SPACE. " Background_id
    * Creating html control
      IF DG_HTML_CNTRL IS INITIAL.
        CREATE OBJECT DG_HTML_CNTRL
             EXPORTING
                  PARENT    = DG_PARENT_HTML.
      ENDIF.
    * Reuse_alv_grid_commentary_set
      CALL FUNCTION 'REUSE_ALV_GRID_COMMENTARY_SET'
        EXPORTING
          DOCUMENT = DG_DYNDOC_ID
          BOTTOM   = SPACE
        IMPORTING
          LENGTH   = DL_LENGTH.
    * Get TOP->HTML_TABLE ready
      CALL METHOD DG_DYNDOC_ID->MERGE_DOCUMENT.
    * Set wallpaper
      CALL METHOD DG_DYNDOC_ID->SET_DOCUMENT_BACKGROUND
        EXPORTING
          PICTURE_ID = DL_BACKGROUND_ID.
    * Connect TOP document to HTML-Control
      DG_DYNDOC_ID->HTML_CONTROL = DG_HTML_CNTRL.
    * Display TOP document
      CALL METHOD DG_DYNDOC_ID->DISPLAY_DOCUMENT
        EXPORTING
          REUSE_CONTROL      = 'X'
          PARENT             = DG_PARENT_HTML
        EXCEPTIONS
          HTML_DISPLAY_ERROR = 1.
      IF SY-SUBRC NE 0.
        MESSAGE I999 WITH 'Error in displaying top-of-page'(036).
      ENDIF.
    ENDFORM.                    " HTML
    Regards
    Vijay

  • Leave to screen 0 acts different

    I have coded OLE automation to create a spreadsheet from the report program. When the spreadsheet is done, it automatically saves it and the control comes to the list output screen of the program. When I hit Back(F3)from here, instead of going back to the SAP/USER menu, it gives me a blue screen. When I commented the OLE automation part, the back arrow takes me right . Can anybody explain me why is this happening? I appreciate your help.
    I opened a thread 4/5 days back for the same issue, but then I thought this was happening because I was using the selection-screen begin/end of screen. But I have strong evidence now that this is happening only when the OLE automation part is on. 
    Thanks
    Anupama

    Hi ,
    I have free statements for all the objects. here is the code for the call selection screen 99.
    start-of-selection.
        call selection-screen 99.
        if sy-subrc eq 0.
          perform get_companies.
          perform get_licenses.
          perform get_bps.
          perform display_output_summ.
          perform prepare_excel_sheet.
        else.
          leave to screen 0.
        endif.
    The last subroutine prepare_excel_sheet is the one when commented out, I have no problem. That is the subroutine, where I do all the OLE automation. Thank you  all for your  help.

  • Sample prg how to use leave to screen

    hi,
    I am working on reports , BDC call transaction, application server or the presentation server has to be choosen, the problem is that i need to have the error message in the same screen where the file is entered.
    I tried giving leave to screen it not working.

    Hi anitha,
    1. I don't know whether i understood u r question.
    2. issue message of type S , or I
       and then write
      LEAVE LIST-PROCESSING.
    regards,
    amit m.

  • When loading video or tv shows it is taking as long as 14 hours plus - if I leave the loading screen it doesn't continue to load? So you have to wait without leaving the screen for 14 hours?

    When loading video or tv shows it is taking as long as 14 hours plus - if I leave the loading screen it doesn't continue to load? So you have to wait without leaving the screen for 14 hours? Unfortunately - I've been reading that this lengthy download problem is quite common - although I thought I saw where someone had loaded videos the day before and then had them to watch later. So, my first rental - I downloaded it overnight - then we go to watch it tonight and it proceeds to start loading again...saying it will be ready in 14 hours and 21 minutes!!! Am I doing something wrong here? If anyone has advice - I would greatly appreciate it. This is the first apple product that I am disappointed with

    When loading video or tv shows it is taking as long as 14 hours plus - if I leave the loading screen it doesn't continue to load? So you have to wait without leaving the screen for 14 hours? Unfortunately - I've been reading that this lengthy download problem is quite common - although I thought I saw where someone had loaded videos the day before and then had them to watch later. So, my first rental - I downloaded it overnight - then we go to watch it tonight and it proceeds to start loading again...saying it will be ready in 14 hours and 21 minutes!!! Am I doing something wrong here? If anyone has advice - I would greatly appreciate it. This is the first apple product that I am disappointed with

  • Modify generated leave approval screen

    I need to add a checkbox to the leave approval screen so that the manager can indicate if supporting documention has been sighted.
    Task TS20000193 usea BO FORM-HTMLPROCESS to call program SAPMWS2000081H with transaction code WS20000081.
    I tried copying the program and includes but there are more includes that are generated from I don't know where.
    What is the correct/best way to modify screen 150 in this program?
    Is there another way of going about it?

    Hi Neil,
    I probably shouldn't say this but... here's one exception to the rule about modifying SAP standard. Just change it. Make sure you have a backup available.
    a) It's hellishly complex to copy as there are a lot of little objects that interact & it's quite nasty code with individual tasks hardcoded. seen. Some OSS notes even recommend changing bits of code when you change the WF tasks.
    b) Any difficulties you may experience due to modding the standard will be less than the difficulties due to copying.
    c) That incarnation of leave request has reached the end of it's life. The ECC6 version has been completely rewritten form scratch and shares no common elements with it whatsoever, so upgrade problems are also not a factor.
    d) Because it's been around for some time I don't imagine there will be too many patches, which aren't that difficult to resolve anyway.
    Cheers,
    Mike

  • Differnece between EXIT and LEAVE TO SCREEN or LEAVE PROGRAM?

    HI Experts,
    Differnece between EXIT and LEAVE TO SCREEN or LEAVE PROGRAM?
    thanks in advance

    Syntax
    EXIT.
    Effect
    If the EXIT statement is executed outside of a loop, it will immediately terminate the current processing block.
    After the prodessing block has been executed, the runtime environment behaves in such a way that it follows with the exception Reporting Event Blocks START-OF-SELECTION and GET the schema from Leave Processing Blocks.
    After the Reporting Processing Blocks START-OF-SELECTION and GET have been exited using EXIT, the runtime environment does not trigger any further reporting events. Instead, it directly calls the list processor for displaying the basic list.
    Note
    We recommend using EXIT only within loops (see EXIT (loops) ). Instead, use RETURN to leave processing blocks.
    LEAVE [TO] SCREEN
    Syntax
    LEAVE { SCREEN | {TO SCREEN dynnr} }.
    Variants:
    1. LEAVE SCREEN.
    2. LEAVE TO SCREEN dynnr.
    Effect
    This statement ends the processing of the current screen. The current processing block of the ABAP program and the current processing block of the dynpro are left immediately.
    Variant 1
    LEAVE SCREEN.
    Effect
    The variant LEAVE SCREEN calls the current next screen. This is either statically specified in the properties of the current screen or has been set before using the statement SET SCREEN.
    Variant 2
    LEAVE TO SCREEN dynnr.
    Effect
    The variant LEAVE TO SCREEN calls the screen with the number dynnr as the next screen. A data object of the type n of the length 4 is expected for dynnr. It must contain either the screen number of a screen in the main program of the current program group or the value 0. Otherwise, an exception that cannot be handled is raised. This statement is a short form of the statements SET SCREEN dynnr and LEAVE SCREEN.
    Note
    This statement does not terminate the entire dynpro sequence; it branches to an additional screen in the same sequence. Only if the number 0 is used to branch to the next screen, LEAVE SCREEN terminates the screen sequence.
    LEAVE PROGRAM
    Syntax
    LEAVE PROGRAM.
    Effect
    This statement immediately ends the current main program and deletes its internal session - including all loaded programs, instances, and their data .
    The LEAVE PROGRAM statement can appear anywhere within any processing blocks. It ends the program regardless of the program/object or the program group of the internal session in which it is executed.
    Regards,
    Pavan P.

  • Leave the screen without process next instructions.

    Hi All,
    In my module pool program  in PAI modules I keep one information message after getting the information message the control should not go further program lines, it should stop there and selection screen should appear with input values the user will correct the input value and run the program.
    How can I forcefully exit the another modules(program lines).
    Thanks and regards,
    Krish.......

    Hi Krish,
    If i understood the problem correctly, you need to use EXIT statement.
       IF flag EQ 'X'.
          MESSAGE i087(ztest) DISPLAY LIKE 'E'.
          EXIT.
      ENDIF.
    Depending on screen sequence use it.
    If you want to skip some screens and come back to particular screen after some user action ;
    you can use SET SCREEN 0 and then LEAVE TO SCREEN 0.
    Please read F1 help for it.
    I hope this will help you.
    Regards,
    Rahul

  • What is the diffrence of 'call screen 100' and 'leave to screen 100'

    Thank u

    hi,
    You can insert a screen sequence. This adds another layer to a stack.
    You insert a screen sequence using the CALL SCREEN <nnnn> statement.
    Note: Layers created in this way must be removed afterwards. You can do this by setting the next screen
    statically or dynamically to the initial value (0) an the end of the inserted screen sequence.
    To interrupt processing of the current screen and branch to a new screen (or sequence of screens), use
    the CALL SCREEN <nnnn> statement. The screen <nnnn> must belong to the same program.
    In the program, the system constructs a stack. The stack has to be destroyed before the end of the
    program.
    To return to the statement following the CALL SCREEN statement, you can use either SET SCREEN 0.
    LEAVE SCREEN. or LEAVE TO SCREEN 0. The screen that called the other screen is then processed
    further.
    If you use the above statements outside a call chain, the program terminates, and control returns to the
    point from which it was called. You can also terminate a program using the ABAP statement LEAVE
    PROGRAM.
    To interrupt processing of the current screen and branch to a new screen (or sequence of screens), use
    the CALL SCREEN <nnnn> statement. The screen <nnnn> must belong to the same program.
    In the program, the system constructs a stack. The stack has to be destroyed before the end of the program.
    To return to the statement following the CALL SCREEN statement, you can use either SET SCREEN 0.
    LEAVE SCREEN. or LEAVE TO SCREEN 0. The screen that called the other screen is then processed
    further.
    To specify the next screen and leave the current screen in a single step, use the LEAVE TO SCREEN <nnnn> statement.
    Hope this helps, DO reward.
    Edited by: Runal Singh on Apr 3, 2008 3:11 PM

  • Problem with syntaxes and structures in unicode

    1. i have a problem with syntax
    this is old syntaxes
    TRANSLATE c ...FROM CODE PAGE g1 ... TO CODE PAGE g2
    new systems should use this class instead of above
    CL_ABAP_CONV_IN_CE
    it reads data from a container and converts it to the system format.
    my old syntax is TRANSLATE header-id FROM CODE PAGE file_tab-codepage.
    i need to change to new one by using above class how to do it
    2. I have a structure are_buffer and i am working on upgrade of a old report , i have used a sap predefined structure callled arc_buffer from se11, now when i am using offset in one of the perform statement like
    PERFORM read_file USING handle_tab_wa-offset record_len
    CHANGING arc_buffer(record_len)
    error_handling
    p_message.
    but the system throws a error called ''the structure arc_buffer(record_length) does not start with character-type field''.
    i cannot change the structure becoz its sap standard structure .
    how to get out of this.

    Moderator message - Cross post locked
    Rob

  • Kludge to make less, vim et al. leave the screen uncluttered enjoy!

    I have written a script which leaves the screen uncluttered when finishing less.
    This script is written for bash in the "good old terminal", but works well with
    iTerm too. I wrote this script because less is opposite of more as less is so
    much more as more is so much less.
    I hope you will use this script and reap the rewards of using less while reading
    textfiles, gaining from less's features, avoiding the cluttering which may have
    made you disliking using less. You can make a copy of the script and modify and wrap
    the script around any other characterbased program which clutters your terminal screen.
    The script works by beeing placed in your ~/bin which I assume is before
    /usr/bin in your $PATH where the binary less resides. You must modify the paths
    in the script if they are different from that. (both the binary less, the script,
    and the kludge.scr)
    The script installs an interrupthandler which are triggered by changing the
    windowsize. The interupthandler figures out what it must do to preserve
    your screen when you exit less, and just does so, except for four characters
    to the extreme left on one line. (wich may well be part of your prompt).
    The interrupthandler gets its work done, by calling a kludge which are
    relatively referenced in the script from your homefolder, -presumes ~/bin
    - YOU MUST EDIT THE SCRIPT OTHERWISE. The configuration is like it is because
    that is what it takes to make the correct things happen in bash.
    I think this could have been accomplished much easier using another shell,
    but most people uses bash, especially newcomers, and they deserve to have
    it as easy as possible, while reaping the productivity gains laying dormant
    in the Unix core, so I hope you will share the script with you liberally,
    if you think it is worth the time and the work it takes to "install" it.
    I hope you will give this script a try, as to make less work comfortably for you,
    I have included an environment variable with all settings I like in less, which
    you may modify.
    Less was the first program I had that made me think "wow" back in 1986, beeing used
    to the "more" command, - which was, and is so much less than less. You can for instance
    invoke BBedit with a file you are viewing in less by pressing "v" if you have BBedit
    specified in the $EDITOR variable. You can pipe some text to the clipboard.
    Or you can pipe some lines out of a document you are viewing in less and into
    a file while viewing, you can load it with multiple files, and search them all,
    a programemer can make less work with tagfiles; you can have less create a logfile
    of what you read and, you can even scroll backwards. All in all less is a very handy
    tool which I think everybody would gain from using,in opposite to more.
    Especially when it leaves the screen uncluttered.
    Great care have been taken in order to make this kludge work properly.
    Still I MAKE ABSOLUTELY NO WARRANTIES ABOUT WHATSOEVER AND ANYTHING.
    -USE IT AT YOUR OWN RISK.
    You may do whatever you wish to do with it, aside from selling it alone, but you
    are free to do whatever that you please with it, aside from distributing
    malfunctioning copies or incomplete copies or tinker with the Copyright notice
    in the scripts.
    -------------------------------------------------- here comes the kludge for less - sends with you a tar as well. 8859 - encoded I think.
    #! /bin/bash
    # Less - lets us keep our screen nice even after resize, having used less or any other
    # character based program - like vim, which may leave an unorderly screen.
    # The fact that programs do clutter up the screen is because they probably didn't figure
    # that we one day would be able to resize our terminals when they specified the standards at
    # Ansi back in the 60's.
    # Installing : put it together with "kludge.bash" in your $HOME/bin folder ( ~/bin ).
    # its intended to work with the bash shell under MacOsX, the binary less is supposed
    # to reside in /usr/bin, if it isnt; ("which less" reveals where), adjust the path.
    # less - to be placed in the ~/bin folder is the wrap around less to make it behave
    # Copyright 2008 Tommy Bollman Public Domain. -No WARRANTIES ABOUT WHAT SO EVER-
    # Please do modify it for other programs which need helps with its cleanup as well.
    # ~ is an expansion for your home directory aka /Users/John\ Doe
    # Please document your version properly if you are posting it, relieving others.
    export LESS=" -I -r -f -J -S -g -M -x 4"
    # -I ignore case when searching
    # -r "raw" do not preparate ctrl-chars,
    # -f force open special files (may be binary) BEWARE OF ANSISEQUENCES.
    # -J show status column
    # -S chop long lines.
    # -g highlight on last hit in the search.
    # -M Most Verbose status column...
    # -x 4 tabspacing = 4
    # -------------------------------------- the screen handling starts here.................
    ORIGLINES=$LINES
    ESC=`printf "\e"`
    ScreenRedraw_off=`echo -n "$ESC""[8m"`
    ScreenRedraw_on=`echo -n "$ESC""[0m"`
    function OkayScreen()
    export PS1="" # Turns off the prompt to avoid cluttering..
    echo -n ${ScreenRedraw_off}
    CURLINES=`bash -i < ~/bin/kludge.bash `
    # ^^^^^^^^^^^ NB! the path where kludge.bash should be placed.
    if [ $CURLINES -gt $ORIGLINES ] ; then
    TO_SKIP="$(expr "$CURLINES" '-' "$ORIGLINES")"
    if [ $TO_SKIP -lt 3 ] ; then
    TO_SKIP="$(expr "$TO_SKIP" '-' '2')"
    else
    TO_SKIP="$(expr "$TO_SKIP" '-' '1')"
    fi
    tput cuu 1 #cursor up one line
    echo -n ${ScreenRedraw_on}
    echo -n "\$####" #restores an erased '$' making only 3 chars disappear.
    # ^ $ = prompt - $PS1. .(I have just a dollar here but if yours is longer,
    # you can add the first four if it's static, and you'll loose nothing!!)
    echo -n ${ScreenRedraw_off}
    tput cud $TO_SKIP # move cursor to where it should be.
    echo -n ${ScreenRedraw_on}
    echo # activate the cli at correct position.
    else
    tput cuu 2
    echo ${ScreenRedraw_on}
    fi
    trap OkayScreen SIGWINCH
    /usr/bin/less $@
    # ^^^^^^^^ NB! The path where the BINARY less is installed.
    trap '' SIGWINCH
    -------------------------------------------------------------------------------- and here is the kludge wich makes it all work!
    #! /bin/bash
    # kludge.scr - to be placed in the ~/bin folder is the inner workings of the bash script named less
    # Copyright 2008 Tommy Bollman
    PS1=""
    shopt -s checkwinsize
    echo $LINES
    ----><---------------------- EOF.

    I have written a script which leaves the screen uncluttered when finishing less.
    This script is written for bash in the "good old terminal", but works well with
    iTerm too. I wrote this script because less is opposite of more as less is so
    much more as more is so much less.
    I hope you will use this script and reap the rewards of using less while reading
    textfiles, gaining from less's features, avoiding the cluttering which may have
    made you disliking using less. You can make a copy of the script and modify and wrap
    the script around any other characterbased program which clutters your terminal screen.
    The script works by beeing placed in your ~/bin which I assume is before
    /usr/bin in your $PATH where the binary less resides. You must modify the paths
    in the script if they are different from that. (both the binary less, the script,
    and the kludge.scr)
    The script installs an interrupthandler which are triggered by changing the
    windowsize. The interupthandler figures out what it must do to preserve
    your screen when you exit less, and just does so, except for four characters
    to the extreme left on one line. (wich may well be part of your prompt).
    The interrupthandler gets its work done, by calling a kludge which are
    relatively referenced in the script from your homefolder, -presumes ~/bin
    - YOU MUST EDIT THE SCRIPT OTHERWISE. The configuration is like it is because
    that is what it takes to make the correct things happen in bash.
    I think this could have been accomplished much easier using another shell,
    but most people uses bash, especially newcomers, and they deserve to have
    it as easy as possible, while reaping the productivity gains laying dormant
    in the Unix core, so I hope you will share the script with you liberally,
    if you think it is worth the time and the work it takes to "install" it.
    I hope you will give this script a try, as to make less work comfortably for you,
    I have included an environment variable with all settings I like in less, which
    you may modify.
    Less was the first program I had that made me think "wow" back in 1986, beeing used
    to the "more" command, - which was, and is so much less than less. You can for instance
    invoke BBedit with a file you are viewing in less by pressing "v" if you have BBedit
    specified in the $EDITOR variable. You can pipe some text to the clipboard.
    Or you can pipe some lines out of a document you are viewing in less and into
    a file while viewing, you can load it with multiple files, and search them all,
    a programemer can make less work with tagfiles; you can have less create a logfile
    of what you read and, you can even scroll backwards. All in all less is a very handy
    tool which I think everybody would gain from using,in opposite to more.
    Especially when it leaves the screen uncluttered.
    Great care have been taken in order to make this kludge work properly.
    Still I MAKE ABSOLUTELY NO WARRANTIES ABOUT WHATSOEVER AND ANYTHING.
    -USE IT AT YOUR OWN RISK.
    You may do whatever you wish to do with it, aside from selling it alone, but you
    are free to do whatever that you please with it, aside from distributing
    malfunctioning copies or incomplete copies or tinker with the Copyright notice
    in the scripts.
    -------------------------------------------------- here comes the kludge for less - sends with you a tar as well. 8859 - encoded I think.
    #! /bin/bash
    # Less - lets us keep our screen nice even after resize, having used less or any other
    # character based program - like vim, which may leave an unorderly screen.
    # The fact that programs do clutter up the screen is because they probably didn't figure
    # that we one day would be able to resize our terminals when they specified the standards at
    # Ansi back in the 60's.
    # Installing : put it together with "kludge.bash" in your $HOME/bin folder ( ~/bin ).
    # its intended to work with the bash shell under MacOsX, the binary less is supposed
    # to reside in /usr/bin, if it isnt; ("which less" reveals where), adjust the path.
    # less - to be placed in the ~/bin folder is the wrap around less to make it behave
    # Copyright 2008 Tommy Bollman Public Domain. -No WARRANTIES ABOUT WHAT SO EVER-
    # Please do modify it for other programs which need helps with its cleanup as well.
    # ~ is an expansion for your home directory aka /Users/John\ Doe
    # Please document your version properly if you are posting it, relieving others.
    export LESS=" -I -r -f -J -S -g -M -x 4"
    # -I ignore case when searching
    # -r "raw" do not preparate ctrl-chars,
    # -f force open special files (may be binary) BEWARE OF ANSISEQUENCES.
    # -J show status column
    # -S chop long lines.
    # -g highlight on last hit in the search.
    # -M Most Verbose status column...
    # -x 4 tabspacing = 4
    # -------------------------------------- the screen handling starts here.................
    ORIGLINES=$LINES
    ESC=`printf "\e"`
    ScreenRedraw_off=`echo -n "$ESC""[8m"`
    ScreenRedraw_on=`echo -n "$ESC""[0m"`
    function OkayScreen()
    export PS1="" # Turns off the prompt to avoid cluttering..
    echo -n ${ScreenRedraw_off}
    CURLINES=`bash -i < ~/bin/kludge.bash `
    # ^^^^^^^^^^^ NB! the path where kludge.bash should be placed.
    if [ $CURLINES -gt $ORIGLINES ] ; then
    TO_SKIP="$(expr "$CURLINES" '-' "$ORIGLINES")"
    if [ $TO_SKIP -lt 3 ] ; then
    TO_SKIP="$(expr "$TO_SKIP" '-' '2')"
    else
    TO_SKIP="$(expr "$TO_SKIP" '-' '1')"
    fi
    tput cuu 1 #cursor up one line
    echo -n ${ScreenRedraw_on}
    echo -n "\$####" #restores an erased '$' making only 3 chars disappear.
    # ^ $ = prompt - $PS1. .(I have just a dollar here but if yours is longer,
    # you can add the first four if it's static, and you'll loose nothing!!)
    echo -n ${ScreenRedraw_off}
    tput cud $TO_SKIP # move cursor to where it should be.
    echo -n ${ScreenRedraw_on}
    echo # activate the cli at correct position.
    else
    tput cuu 2
    echo ${ScreenRedraw_on}
    fi
    trap OkayScreen SIGWINCH
    /usr/bin/less $@
    # ^^^^^^^^ NB! The path where the BINARY less is installed.
    trap '' SIGWINCH
    -------------------------------------------------------------------------------- and here is the kludge wich makes it all work!
    #! /bin/bash
    # kludge.scr - to be placed in the ~/bin folder is the inner workings of the bash script named less
    # Copyright 2008 Tommy Bollman
    PS1=""
    shopt -s checkwinsize
    echo $LINES
    ----><---------------------- EOF.

  • ESS Leave request screen giving a critical Error in production server

    Friends,
    We are in a critical face of ESS implemetation.
    We are doing an ESS MSS implementation for country grouping 99.
    When we moved our changes to production server after succesful testing in quality, getting the following Critical error for Leave Request Screen.
    java.lang.IndexOutOfBoundsException: Index: 0, Size: 0
         at java.util.ArrayList.RangeCheck(ArrayList.java:512)
         at java.util.ArrayList.get(ArrayList.java:329)
         at com.sap.aii.proxy.framework.core.JcoBaseList.get(JcoBaseList.java:272)
         at com.sap.aii.proxy.framework.core.AbstractList.get(AbstractList.java:230)
         at com.sap.tc.webdynpro.modelimpl.dynamicrfc.DynamicRFCList.get(DynamicRFCList.java:281)
         at com.sap.tc.webdynpro.progmodel.context.Node$ModelElementList.getElement(Node.java:2543)
         at com.sap.tc.webdynpro.progmodel.context.Node.getElementAtInternal(Node.java:621)
    Other areas like personal Info & who is who are working fine.
    Leave request was working fine in Development and Quality servers and it never worked in Production server.
    It worked fine with same config, with same master data and same employee & org structure in quality server.
    We tried the following things:
    1. Checked and confirmed the sequence of transports for configs and Developments to Quality and Production.
    Even compared the table level entries and ABAP codings B/n dev and Production. All are same.
    2. Moved the workflow changes to production and activated the same. No change found after that.
    3. Gave SAP all authorization in R/3 and full authorization from portal side as well.
    4. Assigned the userid to different employees and checked the masterdata of employees.
    5. Checked the note 1388426.Every thing mentioned in the note is there in the system.
    6. Verified Rule groups and WEBMO feature are correct and same as in quality.
    As our go live date is very near, request your help .Thanks in advance for your help.
    Regards,

    Customisation of Leave request is mising in your system, please check the rule group using PTARQ.

Maybe you are looking for

  • How to create a new user in OWB that can only view other user's mappings

    Hello Everyone, I am new to OWB and want to know if possible to create different users that can only view other user's mappings without making any changes. Do you know if possible each user can have his own password? Thank you for your help! Jennifer

  • Loose backspace key

    Hi, this seems to be my fourth or fifth problem with my MacBook (I hope there aren't any more) but my backspace key seems to be worryingly loose. Is this the same on every MacBook?

  • Flat keyboard - no help key - eclipse

    Hi all, on eclipse, context-sensitive help is called by "help"-button. And it works fine with a standard mac-keyboard. But there's no help-button on the new flat keyboards or macbooks. Using AppleShift? doesn't work, creating a new shortcut in eclips

  • Re-install PS issues needing resolution

    I installed PS (CS5) on new Mac Pro (updated to Yosemite OS) and now it says I have color sync problems when I close PS. When I close out of PS, I get the following error message: "Could not save Preferences because the file is locked or you do not h

  • Scanner in cs2

    hello- I just got a G5 with OSX tiger...I am running CS2...i have installed 2 scanners, an Epson 4990 and a Nikon Coolscan 5000...they both work by themselves but I want to use them in Photoshop via the 'import "command...however when I go to file>im