Problem in Unit of measure

Dear Guru,
There is a problem with one material
One material on jan converion ( material master) should change
1 to 7.369 to 1 to 6.39
at the end of feb order is created for that material, Now po will take the old conversion
at the time of R&D iam deleting the info record from Po, then it will take right conversion
Please suggest me why it is happened
Regards
Kashyap Kumar

1 to 7.369 to 1 to 6.39 is this convertion maintained info record.if yes ,after deleting inforecord system will pick convertion from material master.Check inforecord what convertion factor maintained.

Similar Messages

  • Problem with Unit of measurement

    Hi,
    I am having problem with Unit of measurement with different languages.
    Eg:
    In SPRO, I am able to see the unit of measure T3 Description: (Trading unit).  in SAP 200 client .the logon language is EN(english).
    But if I logon into same client(200) with different language DE(german) version, I am not able to see the description in German, the description field is blank.
    Kindly give me a solution for this problem as it is very urgent.
    Thanks in advance.
    Regards,
    Shankar

    Hi Aishwarya,
    I can think of 2 possibilities:
    1. You need to verify passing the Target UoM with the ISO Code as well as the update flag in the 'X' structures.
    2. The material that you are trying to pass some UoM does not have the conversion maintained in the Material Master. (Base UoM --> Target UoM conversion in Material Master, contact Functional Consultant).
    Also, if you can verify by performing the action manually and check if the Sales Order is getting created manually with the Target UoM .
    Regards,
    Pranav.

  • Problem of unit of measurment in production system

    Hi Friends,
    I'm facing a peculiar problem of unit of measurement like error in all quantity and curreny fields in report output after transporting a query from quality system to production system but this query is generated from multiprovdier. what might be the problem.   
    Regards,
    Srinivas.

    Hi Dave,
    Thanks for ur reply. but to trace in monitor it is not showing any error message.
    My Mail ID is [email protected]  Please the send the document
    Regards,
    bharat

  • Conversion Problem in Unit of measure 1PAC=100,000 EA

    Hi Experts,
    I am facing the problem in conversion of Unit of Measures.
    If some material has the conversion unit when we order to Vendor.
    The Unit of measure is EA, the Order unit is PAC.
    The conversion is 1PAC=100,000 EA
    But the System is allowing as 1PAC=10,000 EA only and it is not allowing to enter 100,000 EA and throughing the error
    Entry too long (enter in the format __,___)
    Message no. 00089
    How can we increase the characters of the Unit of measure. Like this we have some 50 Materials, I need to increase the length of the conversion spaces. How to do it, Please guide me.
    rgds
    Swamy

    Hi
    you can check this out the denominator factor is Stored in structure - SMEINH - field UMREN.
    Best option is to maintain decimal place for the UOM , which is more easier to mainatin.
    Even if you go through the note the same is explained. Please read below for Too large numerators and denominators
    When 120000 CM3 = 0,2 tons (TO), you can no longer save numerator and denominator of conversion ratio 600000 CM3 = 1 TO as numerator and denominator may have maximally five digits.
    Here, you must either select a larger volume unit or a smaller unit of weight: With DM3 the conversion ratio would be 600 DM3 = 1 TO, with KG the conversion ratio would be 600 CM3 = 1 KG.
    Generally, the alternative units of measure and the base unit of measure should result in quantities that are in the same dimension since the conversion factors may not be larger than 99999/1 and not smaller than 1/99999.
    Thanks & Regards
    KK
    Edited by: Kishore Kumar Chiluka on Apr 22, 2008 8:25 AM

  • Pricing Record Problem (alternative Unit of Measure)

    I am facing a problem in Pricing i.e that the Price is mainly maintained in Base unit of measure(CRT) but the selling is both in Crates and Bottels and the bottels is alternate UOM and Crate is the main unit of measure 90 % sales in crates. but when i enter the qty in alternative uom i.e is bottel price is not calcuated propery
    Example
    1 crt 24 bt
    Price of one crate =216
    when i enter bottels as uom the price should be 9 but system is showing 9.07

    Hi
    Litres is the Base unit of measure and Bottles and Carats are Sales unit of Measure in Ur case and u have maintained wrong figures
    Please maintained in this fashion
    1) 1 bottle  =  x litres
    2) 1 carat  = y litres
    in this way when u enter the 1 carat in Sales order system will go here and take the price of  1 litre and then multiply by ( This conversion factor in ur case y units)
    so u will get price as 1*y rs .
    In pricing please check what condition record u have maintained . Generally condition records are maintained in Base unit of measure i.e the condition record will say 1litre cost Rs  11 .
    Hope this calrify .
    Please reward -

  • Round off problem in unit of measurement

    Dear Experts
    We are in SAP 4.7 , we are having more than 12 plants using same client.
    One of our plant requirement we were changed the UOM 'Nos' with 3 decimels allowed.So where ever we not useing decimel places we have to use UOM as 'EA' (each).This is dont have any decimel places.
    Now we are in implementation project for our one more new plant in same client. But for them we are going to introduced Batch specific unit of measurement. Base unit of measurement is KG and Batch specific UOM is EA.
    All sale material have both unit of measurement , inward or production posting in KG and we will create batch number. We will enter the coversion value of how many quantity per kg for each batch.This will be in 'EA'
    While i'm doing transfer posting or consumption or sales for the material in UOM 'EA' , it is coming with 3 decimel places.
    If the same UOM 'EA' in normal condition (without batch specific UOM) it is working correctly.It is getting roundoff correctly.
    Please help me out on this.I need the consumption should not be decimel places for UOM 'EA'.
    Suresh

    Hi Senthilkumar SD,
    You have not read the thread before posting.
    It quite clearly states that the UOM EA already has NO DECIMAL PLACES.
    Quote "<b>we have to use UOM as 'EA' (each).This is dont have any decimel places."</b>
    It is good to see lots of people trying to help and so I am pleased to see you trying, but it really doesn't help if you haven't read the question before posting the answer.
    Steve B

  • Unit of measure in BOM

    Hi...
    I have one problem with unit of measure in BOM.
    We can maintain item quantity upto 3 decimal point.My problem is with one of material having consumption of  0.01042 for 1pc of header material.
    Due to constraint in maintining decimal point in BOM we maintained it as 0.011 & it leads to undesired result after BOM explosion.
    I know there is one way of going with base qty. of header to be changed.
    Suggest  other else?How to get out of this.....
    Regards
    Tushar

    Hi Brhamankar...Thanx for your valuable i/p.
    We have got solution to the said problem as below(Without increasing the base quantity of header)...
    1)Create new unit of measure say TP
    2)Maintain it as alternate unit of measure with conversion as 1000TP=1042PC in material master of that component
    3)Maintain the quantity in BOM as 0.01TP
    4)Make plan entry for header level say for 50000
    5)After MRP run , procurement proposal for component as 521PC(Previously it was 550PC because restriction of 3 decimal point, in BOM rounded with 0.01042 =0.011PC)
    6)After MFBF, material consumption is also found ok
    Regards
    Tushar

  • Problem in displaying totals based on the Unit of measurement.

    Hi,
    I have Problem in displaying totals based on the Unit of measurement.
    I want to display the total in the output of the alv based on the unit of measurement. for example i have three fields in the output namely
    Matnr           Quantity      UOM
    51                10              EA
    61                10              KG
    71                10              KG
    In the total i should get
                    10         EA
                    20         KG
    Can anyone tell me how to do this?
    The basic req is the exclude the qty with unit EA(each) in the totals.
    Thanks,
    Amit

    H i,
    you can use the collect statement
    to get the proper result
    loop at itab.  ( all the records)
    move all the fields from itab to another
    collect itab1.
    write: itab1-fields, itab1-fields.
    endloop.
    this will solve your problem
    reward points if helpful,
    thanks & regards,
    venkatesh

  • Unit of measure language problem

    Hi experts,
    I'm selecting matnr and meins from MARA. In SE11 I see the meins in my language (DB), but when I'm executing my program than I see the Unit of measure as 'ST' (Stück).
    Could you help me in how can I get the unit of measure in a certain language?

    Wenonah that won't work since the meins in MARA cannot be found in T006.
    But finally I found a function module which solves my problem:
    CONVERSION_EXIT_CUNIT_OUTPUT
    Thanks everybody to trying to help me, I appreciate it.

  • Alternative Unit of Measurement Problem

    Dear Gurus,
    My problem is once I activate altyernative UOM in material master, while issuing materials it is accepting any UOM along with the UOM which is mentioned .
    For example my Base unit of measure is TO and my alternative UOM is FT3 . But while i am issuing material using HL or CD3 it is accepting and post the entry without any message.
    Kindly help me out to restrict alternative UOM which i am defined in Material Master.
    Thanks in advance
    Best regards
    Soumen

    I am not getting what u are saying. We are using ECC 6.0.
    In bottom left under conversion block
    Numerator
    Denominator
    Exponent
    Additive Constant
    Decimal Pl rounding
    Unit of meas family
    And one more block Convert unit of measuremnt
    Value entry                        1.00 TO
    Conversion to target unit    1000.00000 KG
    Conversion to SI unit          1000.00000 KG
    Apart from this anything is ther kindly describe me the path how to find out.
    Regards
    Soumen

  • Inches as unit of measure causes leading problems

    In Freehand MX 11.0.2 for Windows (using winxp sp2), I cannot
    select inches as my unit of measurement without causing serious
    leading issues. If I set type at 10 point with 12 point leading,
    the program will convert the leading to 12 inches, making it like
    864 points. When using millimeters, it does a similar problem, but
    make it 34 mms, or 34 points. Really frustrating. Anyone else have
    an issue like this? I've reinstalled several times, and
    redownloaded, but to no avail. Also, nothing like this on the known
    issues on Macromedia.com. HELP!!!

    > In Freehand MX 11.0.2 for Windows (using winxp sp2), I
    cannot select inches as
    > my unit of measurement without causing serious leading
    issues. If I set type at
    > 10 point with 12 point leading, the program will convert
    the leading to 12
    > inches, making it like 864 points. When using
    millimeters, it does a similar
    > problem, but make it 34 mms, or 34 points. Really
    frustrating. Anyone else have
    > an issue like this? I've reinstalled several times, and
    redownloaded, but to no
    > avail. Also, nothing like this on the known issues on
    Macromedia.com. HELP!!!
    So it happens with inches too.
    Kevin (adplus91) asked the same question with the title
    "Leading measurements changing".
    My reply was:
    Only solution is to use Points as measurement units. I've
    made keyboard shortcuts for changing between
    millimeters and points. Changing units, however, reset grid
    value to 6 points or 5mm.
    This is a bug Macromedia probably made when they fixed a
    conversion bug in Objects palette. Also Macromedia
    claimed that this is WinXP only problem but it happens in Win
    2000 as well.
    Jukka

  • Material upload: alternate unit of measure problem

    Hello,
    I'm uploading materials using LSMW (BAPI nethod: BUS1001006). I have a problem for the records with alternate units of measure. I put the units in a separate file and map the ISO code and the Numerator. However, I receive an error M3333 for the materials with 2 rows (one basic UoM and other alternate), which says that I have to maintain conversion factors for the alternate UoM. I thought, I'm doing so by providing Numerator (E1BP_MARM-NUMERATOR), but somehow it's not enough.
    Any assistance will be highly appreciated
    Thanks in advance,
    Eli

    Wrong definition in MARMX structure.

  • Alternate unit of measure problem

    Dear All,
    here we have one material.
    1. Base unit of measure is Each ( Ea)
    2. alternate unit of measure is Meter ( M )
    conversion is 2000 M = 1 Each
    here if business is entering 2001 M than system is taking 2 Ea means 4000 Meter..
    so please guide me how to solve this problem
    Thanks
    H shah

    Hi,
    Check any Rounding the UOM in MM purchasing view.
    SAM

  • Unit of measurement problem

    Hi,
    A material has its base unit as "Number" & additional unit as "KG" while creating PR it takes only NO not KG and same follows in PO. How can that be solved?

    Hello
    It will take NO while creating the PR even if you change in Material master purchasing view. i.e. Ordering unit as KG and also in info record. while creating the PO, the unit will be changed to KG based on conversion factor. After Gr, the system will show the stock in NO as NO is base unit of measure. (stock keeping unit).
    If you want to change the base unit of measure, then please refer the following poitns :
    As per the SAP standard functionality , We  want to change the base unit of measure (base unit). for material master,  during the change, the system performs extensive checks in order to avoid inconsistencies in the applications which use the material master .
    In particular, the following checks are performed:
    The base unit must not be defined as an alternative unit of measure for the material
    No International Article Number must be assigned to the base unit
    No proportion/product units must be defined for the material
    No configurable material must be assigned
    The material must not be used as a configurable material-
    Stock must neither exist for the previous period nor for the current period -
    No physical inventory must be active -
    No reservations or dependent requirements must exist for which the deletion indicator is not set
    No planned orders must exist -
    No purchase requisitions, purchase orders or scheduling agreements must exist for which the deletion indicator is not set-
    No WM transfer requirements, no WM quants or no WM posting change notices must exist -
    The material must not be a bill of material
    The material must not be contained in a bill of material -
    The material must not be used as a production resource/tool -
    The material must not be used in task lists -
    No standard cost estimate must exist for the current or future period
    No production orders must exist
    No planned independent requirements must exist
    No run schedule headers must exist
    If the base unit has dimensions, no serial number profile must be assigned
    No sales and distribution documents must exist which have status Not processed or Partially processed
    Other alternative solution in case of Urgency:  
    Creation of a new material master similar to the current material and using the new code for further usage.
    Warm regards
    Ramakrishna

  • Met problem to change unit of measure in material master

    Our prime made mistake when creating material master with MM01. He used wrong unit of measure EA instead of right one M. And when he recognized this issue and tried to change it with MM02 in view Basic1, system prompt him an error message that "Standard cost estimates for the current period already exist".
    So, please help to let me know how can I delete related records about cost estimates and avoid this error. Thanks a lot.

    Robbie,
    You can delete Cost estimates using T-code:  CKR1 , I am not sure if you can change UoM if you have any goods movements  on the material. The best option would be create new material with correct UoM and transfer stock from old Material to New one with proper Conversion.
    Thanks
    Sivaram

Maybe you are looking for

  • ABAP+JAVA stack and oracle dataguard

    Hi all, I use Oracle Dataguard for my Data recovery System. How can I manage tha Java part of nw2004s. In case of failover or switchover, the ABAP part is OK but the J2EE cannot start. Thank's for your help, Regards Oracle 10.2.0.2 on Windows 2003 x6

  • Call sql file from plsql

    Hello, I am stuck for many days in this issue. Hope someone helps me out. I am using Oracle 11. I am writing an utility of Purging the data from the database base on certain criteria. We don't have physical(actual) partitions present on our system(si

  • How do you count the frequency of a booloen signal?

    Hi, I'm new to LabVIEW, so I suspect this is propbably quite a simple problem. I'm developing an optical tacometer for a model gas turbine engine. I have a boolean signal in labview switching between 4 and 26Hz. I need a live readout of the frequency

  • Network render engine with projects over 2gb?

    I recently set up a network render farm using Adobe CS4 and adobe's render engine.  I have no problem collecting my files over my network using the renderfarm for projects with resource files and project files smaller than 2 GB.  However, working wit

  • Why does music differ in quality between devices,do ipod classic/iphone/macbook and nano have different power output ratings

    Why does my music sound so differant on seperate devices ?. same song differs in quality between ipod classic , nano , macbook and ipad. do the devices have power output ratings if so is one more powerful than the other ?. same song , same headphones