Problem in variable

hi,
i created one variable of type customer exit zc00000n42 single value .
ZC00000N39 is a variable of type manual input for date .
let say ZC00000N39 = 30.04.2007
i need all values less than 01.04.2007
error in enhancement
in cmod  :
WHEN 'ZC00000N42'   .
    LOOP AT i_t_var_range INTO loc_var_range
        WHERE vnam = 'ZC00000N39'.
     l_s_range-low(6) = loc_var_range-low(6) .
     l_s_range-low+6(2) = '01' .
     l_s_range-opt = 'LT'.
     append l_s_range to e_t_range .
     endloop .
i gave it as LT less than value in low but its showing me error
my scenario is i have to return all dates less than 01.04.2007
plz let me know where i m wrong .

<FONT FACE = "Tahoma", Font Color = "Blue">
Hi
<Br>
Declare temp1 and temp2 as suitable date variables and try below code:<Br><Br>
WHEN 'ZC00000N42' .<Br>
LOOP AT i_t_var_range INTO loc_var_range<Br>
WHERE vnam = 'ZC00000N39'.<Br>
temp1 = loc_var_range-low.<Br>
temp2 = temp1(6).<Br>
temp2+6(2) = '01'.<Br>
l_s_range-low = temp2.<Br>
l_s_range-opt = 'LT'.<Br>
append l_s_range to e_t_range .<Br>
endloop .<Br>
<Br><Br>Hope it helps.
<Br>
Cheers
Abhijit
<Br>* It's a good habit to reward someone with points in SDN if you think his/her
response was helpful to you
</FONT>

Similar Messages

  • Problem with variables in formulas when using CrystalReportViewer

    Post Author: Aksu
    CA Forum: Formula
    Hi! I have a problem with variables in Crystal Reports formulas, when using CrystalDecisions.Windows.Forms.CrystalReportViewer class from VS2005-project. ReportViewer always gives error:*************Crystal Report Windows Forms ViewerThis field name is not known.Details: errorKindError in File C:\{dir&#93;}\{file}.rpt:Error in formula <mCustomerAttributes>.'Dim result As String'This field name is not known.Details: errorKind ************* Report without variables works fine with Viewer and in Crystal Reports Designer report with variables works also fine. I have tried with both "formula-syntaxes" - basic and crystal. But Viewer always gives error when trying to define new variable.I think the problem might be with CR -versions, because VS-project has formerly been designed to VS2003 and CR9 or 10. Now I'm using VS2005 and CR11. Though I have changed all references to new CrystalDecisions-asseblies (Ver.11.0.3300.0), when I debug the project and checkout the Viewers ReportSources FormatEngine Shows version CR9_2.... I have no idea where it gets this version...***************DEBUG-view when Viewer is created *******************CrystalReportViewer    |_        ReportSourceClassFactoryName ... , Version=11.0.3300.0 , ...    |_            ReportSource            |_                FormatEngine    {CrystalDecisions.CrystalReports.Engine.FormatEngine}                        |_                        ClientVersionHeader    {CrystalDecisions.Shared.ReportServiceVersionHeader}                            |_                            |    version = 920     (int)                            |_                                Static members                                            |_                                        VER_CR9    = 920    (int)**************************************** Could anyone have any answers or tips for this problem? I'd really appreciate it... ---Aksu

    Has anyone been able to answer this question?
    I am having the same problem:
    I am designing a report in Crystal Reports XI Developer that contains parameters, which are passed to a stored procedure and are also used within formulas ( in Crystal Syntax ie. {?FORMAT_ID} ) in the report itself.
    I can run the report successfully in CRXI Developer.  The formulas use the correct values from the parameters entered during execution and everything looks good.
    I then deploy the report to Business Objects Enterprise XI.  I do all of the things necessary to manage the report including setting up the proper database connection information and default parameter values.
    When I run the report using the Crystal Report Viewer, I get the following error message:
    Error in File Forecasting.rpt:
    Error in formula <Report Format>.
    'if (not isNull({?FORMAT_ID} ) ) then
    This field name is not known.
    Details: errorKind
    This happens when I press the "Preview" button in the Manage Object dialog from Crystal or when I run the report using InfoView.
    I have changed the formulas and it doesn't seem to matter what the specific content of the formula is; other than the existence of a parameter reference in the formula.  If I comment out the parameter and replace it with a hard-coded value, it gets through the formula fine.
    Does Business Objects Enterprise XI support crystal reports with parameter references in the formulas?
    Thanks,
    Tim H.
    Edited by: Tim Haley on Nov 25, 2008 11:11 PM
    Edited by: Tim Haley on Nov 25, 2008 11:12 PM

  • Problem returning variables from dynamic SQL/PLSQL

    Hi, I have a problem I am trying to solve using a very short piece of dynamic SQL or PLSQL but I am having problems getting the variable values out of the dynamic block.
    I have 16 counters whose names are made up of three variable parts - 'scheme', 'contributory category' and 'employment category'
    The 'scheme' can be either 'no1', 'no2', 'off', 'cg' or 'amc'
    The 'contributory category' can be either 'cont' or 'noncont'
    The 'employment category' can be either 'ft' or 'pt'
    (There are only 16 because only 16 combinations are possible)
    For example the total counter name could be 'v_cg_noncont_ft_count'
    I have created a variable by concatenating the various elements called v_incr_count_name which holds the name of the counter I want to increment.
    I am running this whole thing within an anonymous PLSQL block so I cannot use global variables meaning that my variables are not visible within a dynamic PLSQL block.
    I believe this means that either I need to bind the variables within a PLSQL block or use a SELECT FROM INTO SQL block.
    I have tried a few solutions with no luck such as the following PLSQL:
    v_incr_count := 'v_'||v_scheme||'_'||v_cont_cat||'_'||v_emp_cat||'_count';
    sql_stmt := 'BEGIN :a := :a + 1; END;';
    EXECUTE IMMEDIATE sql_stmt USING v_incr_count_name;
    Unfortunately I am getting the 'IN bind variable bound to an OUT position' error which I believe is because it is trying to return a value into v_incr_count_name which has been defined by default as an IN variable. The problem is that I need to store the returned value into the variable whose name is stored in v_incr_count_name.
    Another solution I tried is:
    v_incr_count_name := 'v_'||v_scheme||'_'||v_cont_cat||'_'||v_emp_cat||'_count';
    sql_stmt := 'SELECT '||v_incr_count_name||' + 1 FROM DUAL';
    EXECUTE IMMEDIATE sql_stmt INTO v_return;
    This solution gives me an 'Invalid colum error'
    Any help would be greatly appreciated
    Cheers, Dan

    Repost:
    Problem with variables in dynamic SQL/PLSQL

  • Problem with variable

    Hi. I'm making a form for work for people to book places on
    training courses. Having an annoying problem with variables that
    i'm hoping has a simple solution. Any help with this will be much
    appreciated.
    All the info is held in an external text file which looks
    like this (but much longer):
    &totalcourses=2&
    &course0=Please choose a course&
    &course1=my course one&
    &totaldates1=3&
    &c1date0=Select a date...&
    &c1date1=15 September 2006&
    &c1time1=Time: 10:00 to 16:00&
    &c1date2=23 January 2006&
    &c1time2=Time: 11:00 to 16:00&
    &c1date3=28 February 2007&
    &c1time3=Time: 12:00 to 16:00&
    &course2=my course 2&
    &totaldates2=3&
    &c2date0=Select a date...&
    &c2date1=15 September 2006&
    &c2time1=Time: 11:00 to 16:00&
    &c2date2=08 January 2007&
    &c2time2=Time: 9:00 to 16:00 &
    &c2date3=15 February 2007
    &c2time3=Time: 12:00 to 16:00&
    The course titles are loaded into an array and then into a
    combobox. When a course is chosen a second combobox loads the
    relevant dates array for that course. When a date is chosen the
    time is shown in a dynamic text box.
    Problem is - if more than one course is on the same date it
    will show the time for the latest course with that date. For
    example - course 1 is on 15 sept at time 10:00 to 16:00, course 2
    is also on 15 sept at time 11:00 to 16:00. When 15 Sept is chosen
    for course one it displays the time for course 2 on this date -
    presumably because it comes later in the text file.
    I've attached the actionscript for this - Can anyone help me
    sort this out??

    Hi. I'm making a form for work for people to book places on
    training courses. Having an annoying problem with variables that
    i'm hoping has a simple solution. Any help with this will be much
    appreciated.
    All the info is held in an external text file which looks
    like this (but much longer):
    &totalcourses=2&
    &course0=Please choose a course&
    &course1=my course one&
    &totaldates1=3&
    &c1date0=Select a date...&
    &c1date1=15 September 2006&
    &c1time1=Time: 10:00 to 16:00&
    &c1date2=23 January 2006&
    &c1time2=Time: 11:00 to 16:00&
    &c1date3=28 February 2007&
    &c1time3=Time: 12:00 to 16:00&
    &course2=my course 2&
    &totaldates2=3&
    &c2date0=Select a date...&
    &c2date1=15 September 2006&
    &c2time1=Time: 11:00 to 16:00&
    &c2date2=08 January 2007&
    &c2time2=Time: 9:00 to 16:00 &
    &c2date3=15 February 2007
    &c2time3=Time: 12:00 to 16:00&
    The course titles are loaded into an array and then into a
    combobox. When a course is chosen a second combobox loads the
    relevant dates array for that course. When a date is chosen the
    time is shown in a dynamic text box.
    Problem is - if more than one course is on the same date it
    will show the time for the latest course with that date. For
    example - course 1 is on 15 sept at time 10:00 to 16:00, course 2
    is also on 15 sept at time 11:00 to 16:00. When 15 Sept is chosen
    for course one it displays the time for course 2 on this date -
    presumably because it comes later in the text file.
    I've attached the actionscript for this - Can anyone help me
    sort this out??

  • Problem with Variable Client Support

    Hello,
    I work with Labview 8.5 and Crio 9014.
    I have a problem with  Variable Client Support. When I try to compile my project I have the following error:
    "The Network Variable Engine and Variable Client Support must be installed on the RT target for this application to function properly..."
    I have read that we have to install the Variable Client Support in Measurement and Automation by right-clicking on the software and then choosing add/remove software but I can't install the appropriate shared variable components because I can't see neither Network Variable Engine and Variable Client Support. So what can I do?
    Can somebody help me?
    Thanks

    I have exactly the same problem. I wanted go through the "Getting Started with the LabVIEW RT module" and when I use wizard for generating new project I get same notification in my VI... 
    The Network Variable Engine and Variable Client Support must be installed on the RT target
    for this application to function properly. If the Network Variable Engine is not supported on
    the target (e.g. FP-2000 with <32MB of RAM), open the project and move the variable library
    to My Computer in the project. Doing this will deploy the variables to localhost but
    will still require that Variable Client Support be installed on the RT target.
    Could someone help please ? 
    Attachments:
    ni.png ‏95 KB

  • Problem with variable in the woorkbook selection screen.

    Hi All,
    I have Problem with Variable in the selection screen. I have four variable in the report in this sequence
    <b>Plant (optional), calendar month (mandatory),  material (optional), Customer (mandatory). </b>
    In Development system, I changed the query to fix the problem for a formula. saved and executed the query. In the selection screen appeared four variables and executed. after executing the query and I saved the work book also. I logged out of the Bex Analyzer. In the RSRT I generated the report by clicking the Generated Report push button. and again logged into the Bex analyzer and ran the work book, now in the selection screen, appeared three Variables only, I am missing the variable <b>Customer</b>.
    The old report which is already  in the Production system is working fine. What could be the mistake I did in the development system.
    It is very urgent, I need to deliver this object as soon as possible.
    Can I anybody help on the same.
    Thanks in advance
    Narendra

    Yunus,
    I did what you said. I removed the variable from characteristic restrictions, saved the query and executed the query, appeared three variables Plant, Calender month and material. executed and saved the work book. disconeted from Bex analyzer, in RSRT Generated Report and logged into Bex analyzer ran the work book for selection Plant, calender month and material and went into change query definition and added the variable for customer which was removed earlier and and ran the query for selections Plant, Calender monmth, Material and customer. saved the work book. disconnected from Bex analyzer and closed all excel sheets and work books. In RSRT Generated Report and again connected to Bex analyzer and ran the work book, now appeared only three variables again missed variable customer.
    Yunus does any missed n the procedure what i did.
    It is helped what Chris was answered.
    Many Many Thaks for your time and replies.
    Thaks in advance
    Narendra

  • Problem with Variable screen in WAD

    Hi ,
    I have a problem with variable screen in WAD , in the varable seen it is displaying only Key , it is not giving any description , but in BEX is is displaying both Key and Description , can any only have an idea why is this happening . this is occuring only for one variable , rest are working fine .
    Thanks,
    Abraham

    Hi Abraham,
    thsi could be a problem from the specisic setting of the infocube. Please check the BEx Settings from the infocube. You can find them by the following steps:
    - search for the infocube
    - doubleclick on the infocube
    - choose an specific infoobjekt
    - right mousebutton and click "specific dataprovider settings"
    - check if the right entries are set
    Hope this will help.
    André

  • Localizing Analytics Web Catalog - problem with variables

    I tried to localize strings in OBI EE Web Catalog. I exported those captions using catalog manager, translate messages in XML file and put them to \Web\Res\l_xx\Captions. It works quite good.
    But there is problem with variables in Title. Replacement of variables STOP working :-( At the page is displayed for example: "@{biServer.variables['MaxDate']}". Variable replacemen works fine in narrative views.
    Do you have some ideas?
    Thanks.

    We have the same problem with presentation variables in titles using externalize strings option, they stopped working after tranlation.
    We tried with Oracle BI EE 10.1.3.2.1 and 10.1.3.3.3 with same result.
    Any ideas?
    Thanks

  • Problem in variable substitution

    Hi experts,
    I need help for a strange problem:
    I have a proxy to file scenario in which I create an xml file; I need to use a field of the mapping to create filename.
    In Receiver CChannel I have used variable substitution, but in message monitoring I got this error:
    Delivery of the message to the application using connection File_http://sap.com/xi/XI/System failed, due to: com.sap.aii.af.ra.ms.api.RecoverableException: Error during variable substitution: com.sap.aii.adapter.file.varsubst.VariableDataSourceException: The following variable was not found in the message payload: Folio: com.sap.aii.adapter.file.configuration.DynamicConfigurationException: Error during variable substitution: com.sap.aii.adapter.file.varsubst.VariableDataSourceException: The following variable was not found in the message payload: Folio.
    FileName Scheme is: DM65_%Folio%.xml
    In variable substitution I have used this reference:
    Folio =    payload:MT_MexicanElectronicInvoice_MyFirm,1,CABFAC,1,Folio,1
    This is the payload of the message that ends in error:
    <?xml version="1.0" encoding="UTF-8" ?>
    - <ns0:MT_MexicanElectronicInvoice_MyFirm xmlns:ns0="urn:MyFirm-EDICOM:MexElectronicInvoice">
    - <CABFAC>
      <IdLabel>CABFAC</IdLabel>
      <Version>3.0</Version>
      <Folio>2100000003</Folio>
      <FecHac>16-11-2011 17:11:17</FecHac>
      <FPago>Advance payment</FPago>
      <Subtotal>9.976,00</Subtotal>
      <TotalFac>11.568,16</TotalFac>
    What is the problem? wrong reference?
    thanks
    Fabio

    Hi,
         Everything looks fine.
    Make sure that there is no extra space after your "%Folio%" under the Variable Substitution.
    Make sure that "Adapter Specific message Attributes" is unchecked in the CC.
    You can do a change in message mapping to create a header field<occurence: 1> map to a constant and call it in var substitution.
    As Mickael suggested above make sure using only lowercase on your variant name  %folio% instead of %Folio%.
    For 1:N muti-mapping with variable substition go through the below links:
    Re: 1: N File Scenario..
    Using Variable Substitution
    i hope it will help you.
    regards,
    ganesh.

  • Problem with Variable Substitution Receiver Adapter

    Hi,
    I need to use a dynamic filename so I'm using the variable substitution in my receiver adapter. BUT, the filename can't appear in the file. So i used this blog in reference --> Solution to the problem encountered using Variable Substitution with XI-SP12
    The PROBLEM is I still get and extra blank line in the file. How can I eliminate this extra line?
    Thanks in advance.
    Using XI 7.0

    Hi Gaurav,
    Data Type:
    Lines
       Line
    Config
       FileName
    XML - example:
    <?xml version="1.0" encoding="utf-8"?>
    <nr1:MT_TP_TipoCambio_Detalle_ECC_Req xmlns:nr1="urn:erplatam/tipocambio:tp:ecc">
    <Lines>
    <Line>USDSOL0000000000003.10000013-09-200813-09-2008V</Line>
    </Lines>
    <Lines>
    <Line>USDSOL0000000000002.50000014-09-200814-09-2008V</Line>
    </Lines>
    <Config>
    <FileName>SIGMA_TCSAP_F081031.DAT.TXT</FileName>
    </Config>
    </nr1:MT_TP_TipoCambio_Detalle_ECC_Req>
    Output - File, has 3 lines should have only 2:
    USDSOL0000000000003.10000013-09-200813-09-2008V
    USDSOL0000000000002.50000014-09-200814-09-2008V
    FCC parameters:
    RecordSet Structure: Lines,Config
    Lines.fieldSeparator 'nl'
    Lines.endSeparator 'nl'
    Config.fieldSeparator 'nl'
    Config.endSeparator 'nl'
    Thanks in advance!

  • Problems with variable speed

    problems with clips switching from constant to variable speed.

    Could you be more specific? What are you doing exactly and what is happening when you do it? Which version of FCP?

  • Problem with variables in dynamic SQL/PLSQL

    Hi, I have a problem I am trying to solve using a very short piece of dynamic SQL/PLSQL but I am having problems getting the variable values out of the dynamic block.
    I need to increment a counter which could be any one of 16 counters I am using and I want to avoid using nested IF statements.
    The variable to be incremented is made up of the 'scheme', the 'contributory category' and the 'employment category' (although not every combination is valid)
    The 'scheme' can be either 'no1', 'no2', 'off', 'cg' or 'amc'
    The 'contributory category' can be either 'cont' or 'noncont'
    The 'employment category' can be either 'ft' or 'pt'
    For example the total variable name could be 'v_cg_noncont_ft_count'
    I have created a variable by concatenating the various elements called v_incr_count_name which holds the name of the variable I want to increment.
    I am running this within an anonymous PLSQL block so I cannot use global variables meaning that my variables are not visible within a dynamic PLSQL block.
    As a result I think I will need to use bind variables with a PLSQL block or a SELECT FROM INTO SQL string
    I have tried various solutions including the following PLSQL solution:
    v_incr_count_name := 'v_'||v_scheme||'_'||v_cont_cat||'_'||v_emp_cat||'_count';
    sql_stmt := 'BEGIN :a := :a + 1; END;';
    EXECUTE IMMEDIATE sql_stmt USING v_incr_count_name;
    Unfortunately I am getting the 'IN bind variable bound to an OUT position' error which I suppose makes sense as I am trying to change the value of a variable in the main PLSQL block from within the dynamic block.
    Another (SQL) solution I tried was:
    v_incr_count_name := 'v_'||v_scheme||'_'||v_cont_cat||'_'||v_emp_cat||'_count';
    sql_stmt := 'SELECT '||v_incr_count_name||' + 1 FROM DUAL';
    EXECUTE IMMEDIATE sql_stmt INTO v_return;
    While this executes and returns the incremented value into v_return, I am still left unable to copy the returned value into the variable whose name is stored in v_incr_count_name
    Any help appreciated
    Cheers, Dan

    this shows the syntax for the using clause
    declare
    a number := 1;
    b number := null;
    v varchar2(10) := 'A';
    begin
    execute immediate 'begin :v1 := :v1 + 1; end;' using in out a;
    dbms_output.put_line(a);
    end;
    /but what you want cannot be done
    SQL> declare
      2  a number := 1;
      3  b number := null;
      4  v varchar2(10) := 'A';
      5  begin
      6  execute immediate 'begin '||v||' := :v1 + 1; end;' using in out a;
      7  dbms_output.put_line(a);
      8  end;
      9  /
    declare
    ERROR at line 1:
    ORA-06550: line 1, column 7:
    PLS-00201: identifier 'A' must be declared
    ORA-06550: line 1, column 7:
    PL/SQL: Statement ignored
    ORA-06512: at line 6the variable "V" contains the name of the desired output variable ("A"). this errors because "A" is not defined within the scope of the dynamic sql.
    "into the variable whose name is stored in v_incr_count_name"
    pl/sql does not support dereferencing variables, so you can't do it.

  • Problem in Variable Substitution (Receiver File Adapter)

    Hi,
    I am facing problem in the variable substitution in receiver file Communication channel. My expected file name is A_C.xml; but my actual output filename obtained is C_C.xml for the below example target file:
    <ProductionSch>
    <CustomField>
    <value>
    <ValueString>A</ValueString>
    </value>
    </CustomField>
    <CustomField>
    <value>
    <ValueString>B</ValueString>
    </value>
    </CustomField>
    <CustomField>
    <value>
    <ValueString>C</ValueString>
    </value>
    </CustomField>
    </ProductionSch>
    I have used the following parameters in the file communication channel:
    File Name Schema: %var1%_%var2%.xml
    Variable Substitution:
    Variable Name                     Reference
    var1                                     payload:ProductionSch,1,CustomField,1,value,1,ValueString,1
    var2                                     payload:ProductionSch,1,CustomField,3,value,1,ValueString,1
    When I try using either of the one in the file name schema and the corresponding variable reference in the variable substitution I am getting the correct output filename as A.xml or C.xml. However, when I give either of the one variable in file name schema and both the variable references in the variable substitution I am getting only C.xml as per the example file.
    Can any of you suggest me where I am wrong or any other suggestion which I can try?
    I cannot use dynamic configuration as I am using multimapping. Multiple file names cannot be generated using dynamic configuration.
    Regards
    Sowmya

    hi Sowmya,
    refer you to this [Note 1581988 - Variable Substitution option does not work properly|https://service.sap.com/sap/support/notes/1581988] (2011.05), as SAP says " when there is more than one variable using the same name as the last element, File Adapter does not select the correct one.... ".
    regards.
    Mickael

  • Problem with Variable imported from SAP in universe

    I am using BO XI R3 with SAP based OLAP Universe.
    I am using a BEx query with a variable to create the universe.
    While using the variable in WebI report, the prompt comes but it has no effect in the report. I have noticed that if I select any measure object in the WebI query, then the prompt is working fine. But If I select dimension objects only, then the filter doesn't work.
    I need to see some dimensions only in the report based on the filter prompt. Is there any specific way to achieve that without selecting a measure object in the WebI query panel ?
    I can delete the filter object in the universe and create my own. But why the filter imported from SAP is malfunctioning ?

    Let me elaborate the problem.
    I am using BEx query (version 7) to build the universe.
    In the BEx query, I have one characteristic "Cons Area" in Rows and one key figure "No of Records" in Columns. In the Characteristic Restrictions, I have one variable B_AREA on Cons Area.
    In my universe, by default, I have :
    1. One dimension object L01 Cons Area for the characteristic Cons Area.
    2. One measure object No of Records for the key figure.
    3. Two LOVs LovB_AREA and LovB_AREABase as hidden dimension objects.
    4. One hidden filter object under class Cons Area for the variable. "Use filter as mandatory in query" checkbox is checked and "Apply on universe" is selected.
    The formula of the objects are as below:
    L01 Cons Area : [0BCS_AREA].[LEVEL01]
    No of Records:     [Measures].[D6UXU0FKYVITGHUL4JRNT6XRH]
    LovB_AREA :     [!V000001].[NAME]
    LovB_AREABase :     [!V000001].[CAPTION]
    Filter :     
    <OPTIONAL>
         <FILTER KEY="[!V000001]">
              <CONDITION OPERATORCONDITION="Between">
                   <CONSTANT TECH_NAME="@Prompt('B_AREA From','A','Cons Area\LovB_AREABase',mono,primary_key)"/>
                   <CONSTANT TECH_NAME="@Prompt('B_AREA To','A','Cons Area\LovB_AREABase',mono,primary_key)"/>
              </CONDITION>
         </FILTER>
    </OPTIONAL>
    Note : LovB_AREABase has a primary key defined on it as [!V000001].[TECH_NAME]
    Now when I am building a WebI report using this universe, If I select Cons Area Object only, then the prompt is coming but has no effect on the result. The data is not being restricted by the prompt.
    But If I select the measure object along with the dimension object in my WebI report, then the prompt is working fine.
    If I delete the filter from universe and build my own filter in WebI query panel, then it is working absolutely fine.
    I can create a filter object in universe also as below which will work.
    <OPTIONAL>
         <FILTER KEY="[0BCS_AREA].[LEVEL01]">
              <CONDITION OPERATORCONDITION="Between">
                   <CONSTANT CAPTION="@Prompt('B_AREA From','A',,mono,free)"/>
                   <CONSTANT CAPTION="@Prompt('B_AREA To','A',,mono,free)"/>
              </CONDITION>
         </FILTER>
    </OPTIONAL>
    But I want to know why the default filter is not working as expected.

  • Problem with variable refresh in WAD

    Hi Experts,
    I have a query in which currency and cal quarter are the variables. The cal quarter is populated using a customer exit to have the current quarter. I have built a webtemplate on this query. Now the problem is:When I run the webtemplate and try to change the currency value (for example EUR to CAD) and select show all values for the cal quarter, i see that the cal quarter is being reset to the default value i.e (current quarter). When i pass a value (say 2.2008) to the cal quarter in the variable screen or in the characteristic restictions in the webtemplate and try to change the currency in the currency drop down, the cal quarter remains same (2.2008) and the keyfigures are displayed with the selected currency.
    Could you provide some inputs so that the cal quarter value is not reset upon selection of "show all values" in the variable screen/drop down and change in currency.
    P.S. No changes at query level are allowed and both query and webtemplate are in 7.0
    Regards,
    Naveen.

    HI Naveen,
    WHere is the customerr Exit of the calquarter used in teh Query. is it in the Filter section or in teh Default values section.
    If the customer Exit variable is used in teh filter section , you will not be able to see data other than the value returned by the customer exit.
    Regrads.
    Shafi.

  • Problem with variable inside split-join

    Hello,
    I'm using Oracle BOM Suite 10.3.0.0 and i want to use the split gateway.
    In general the split activity ends with a join.
    the problem is when i affect a value to a variable between the split and join, it could not get this value after the join, which means after the join the variable becomes empty just like it was before the split.
    could anyone help me please.
    thanks

    HI
    Case 1: Instance variables are not shared:
    At join you can copy the variables from one of the branches to the main instance (that waits at join).
    this.instanceVar = copy.instanceVar
    This will copy the value of variable 'instanceVar' from the instance that just arrived at join to the instance that was waiting at join (main instance)
    Case 2: Instance variables are shared:
    This would mean that the main instance shares its variables with the child instances (instances between split - join). In such a case, when a variable is updated by any of the branches, the change is reflect in all the copies.
    You can set the property to share or not to share instance variables, in the advanced properties of the split activity.
    HTH
    SAtinder

Maybe you are looking for

  • Separate Doc.Type for MRP generated PRs

    Dear All We are facing an issue with MRP process where we want to automate the process from MRP run to PO creation. In source list we will add the existing contracts and make it relevant to MRP so that after MRP run we will get source (vendor defined

  • HOW TO CREATE A COST CENTER

    HI ! ALL I WANT TO KNOW ABOUT HOW TO CREATE A COST CENTER IN SAP . EXAMPLE - ADMINISTRATION DEPT , MARKETING DEPT , PACKING DEPT. REPLAY ME - 09558175176

  • Create table with dynamic table name.

    I'm trying to create a table like select x.*,  convert(nvarchar(20), getdate(), 101) AS LoadDate into table1_20140512 from (        select c1,c2,c3 from table2_20140512        WHERE(LoadDate = (select MAX(LoadDate) FROM table2_20140512   )        uni

  • Selecting "open in new tab" from right click menu does nothing

    I just updated to firefox 24 on OXS. The right click menu now makes no sense. When I right click on a web link, then select "open in new tab" nothing happens. No tab opens. On the other hand, I now see countless irrelevant options for that link, like

  • Show long format date in menue bar

    how do i get the long format -- i.e., Sat. Mar 5, 08 AND the time -- to show in my menu bar? as the help menu suggested, i pulled up the date and time window and specified the long format in international but the menu bar still only shows Mon and the