Problem: logical system has been changed once it has already been assinged

hai,
we have started ebp configuration with a fresh client.and we assinged logical systems,but unfortunately someone has worked in the same client and made his own logical name...but later in console transaction the system promts that you have no backend rfc connection.my senior told that someone has changed..i tried to rectify in smoeac trx....but the system cannot takes the receiver logical id....plz tell me anyone how to solve my problem...hx in advance

Hi
Please check first in scc4 what is the logical system for your client . Ask your administaror to broadcast a message not to change a logical system to every one.so that everyone uses only one logical system for one client.
regards
Muth

Similar Messages

  • Scm:Logical system Name is changed. cannot access BW system.

    Hi,
       plz help me to solve thi problem.
    SCM : Logical system Name is changed. cannot access BW system. system throw an error "Logical System has changed".

    Hi Raj,
    We can create the Logical system name in SALE or BD54 and we can assign the same logical system name in SCC4 for that particular Client.
    If you want to change the logical system name after a client copy or System copy. Use BDLS.
    Thanks,
    Pundari

  • OCI Catalog for Vendor problem : Logical system for catalog not maintained

    We have set up an OCI catalog with on of our vendors. This works fine untill we transfer shopping basket data from Vendor sysem into our SRM-system (SRM5.0). Then data is not being transfered and Vendor Webshop screen remains 'open'.
    in SLG1 i have found an error "Logical system for catalog not maintained. Inform system administrator'
    Anyone an idea what the cause of this error can be or what we need to check ?
    Thanks in advance

    Hi,
    I have not seen that error before. However, I think it may have to do with the LOGICAL_SYSTEM OCI field. Can you check if your punch-out catalog vendor is populating that field? Also, check if you have the correct BP# populated in the catalog configuration and the LOGICAL SYSTEM Field on the define External Webservices is blank.
    SG

  • What is the best way to update a help file once it's already been compiled

    As programs get updated, many of the programmers I write for don't highlight their Microsoft Word help document changes.  This leaves me to re-compile their newest document - creating many headaches for me if the previous document needed hyperlinks and such - I then have to re-create all these again.  Please let me know what suggestions you have - I'm very new to all of this.

    You could start by using Word's compare feature to compare the last document with the current one, then make those changes in the online help.
    After amending the help, use RH's Printed Documentation to push back out the content including your changes. That way, next time you will only have their changes for the current period without the clutter of what you had to edit the previous time.
    Visit www.grainge.org for RoboHelp and Authoring tips

  • How can I edit the author´s info or the book´s titles once they have already been downloaded into ibooks?

    I downloaded several ibooks but some author´s names and titles are not correct.
    When i try to correct them ,it does not allow me to edit that information (author and titles).
    Please help me find a way to fix these books.
    Thank you.

    SocialMediaObsessed.com wrote:
    Is there anyway to tell if he downloaded or accessed any of my apps or downloaded anything?
    You can look at your account in iTunes to view any recent purchases. Change your password as well. 

  • Contract end has some changed !  I was already out of contract..... HELP !!!

    I started service in October 2012 with 3 lines, I've since added 2 more, a few weeks ago I called what I thought was my local asking about the new LG headsets, somehow I spoke to an Ella at the Corporate Store she told me I qualified for $10 off per line because of the 18gb plan we have, and asked if I wanted to do that (I'm all for saving money) NOW I NOTICED THE CONTRACT END ON ALL MY LINES ARE IN 2015, and I was very specific about asking if this would affect my upgrade.........We've been out of contract since January 2014 and was holding on to it because the S5 was coming out........so what's the deal with that, Ella was very sweet but I didn't want my contract status tapered with.

    How To: Direct Message  and   ArnettH_VZW

  • Logical System Change for Production System

    Hi experts
    We have new CRM and BI project.  Logical System name of our ERP production system is not in naming standart. So we want to change logical system name and run BDLS in production system.
    Is there any risk about this prosedure?
    Best Regards...

    Hi,
    It is not advisable to change the logical system in production client once its assigned.
    Regards,
    Nisit

  • Logical System Name changing

    Dear Team,
    We had upgraded BI system from 3.0B to BI 7.0. At the time of upgrade dev
    copy(shadow system) logical system was not changed because most of the data is coming from ETL. Now we want to test the extraction from R/3 Dev.
    R/3 Dev is already connectwed to BW dev 3.0B, Now we need to test
    extraction from R/3 Dev to BW dev copy server( NW2004SR1 ).
    Here we are facing a problem with Logical system. While upgrading the
    same logical sys was copied to BW dev copy.
    What is the procedure to change the existing logical system name in BW
    dev copy and establish connectivity with R/3 dev?
    what is the impact if we run BDLS transaction.
    Thanks& Regards,
    Satish.K.Neni

    Hi Satish,
    Go to transaction SALE -> Basic settings -> Logical systems -> execute "Define logical system" to create a new logical system -> then execute "Assign Logical System to Client"
    That should solve your problem
    Regards
    Juan
    Please reward with points if helpful

  • How to change name of a logical system

    Hi SDN,
                 I am trying to customizing intial download data transfer from ECC to CRM. But in outbound queue of ECC it is showing an error of SYSFAIL with description of logical system name changed. Given note 558701.
    But I don't know old name of logical system.
    1) Can you guys please help how to find the old logical system name there are many logical systems defined in my system.
    2) and how to change it?

    Hi Ravi,
    Since logical system name is changed sombody in past must have ran BDLS to conver logical system name.
    Check tcode SLG1, this tcode will tell you whether there were any logical system conversion done in Past, if it is done then it will tell you from which old logical system its converted to new one. So you can find out old logical system name.
    Once you find out old logical system run BDLS again. It might possible BDLS ran unsuccessfully last time.

  • How do I prove that  signed and finalized PDF has not been changed?

    My organisation would like to use the PDF signing facility that comes with Adobe Reader. Users will be working on Windows 8.1 touchscreen devices and they will ask clients to sign documents using a stylus on the screen. I have been asked how we would know if the PDF has been changed after it has been signed.

    I have heard of this possibly happening after insurance claims but nothing coming from a sealed box. I'm so frustrated by this as my touch screen doesn't work sometimes and this is causing big problems trying to answer calls. I have only had the phone since August. I set the phone up myself from the sealed box and its never been away from me, never have I had to send the phone away for repair or insurance claim.
    Feel like I've got a faulty phone and no one will help me...I trully believe all my phone is all Apple and always has been. I wish I could get photo evidence of inside the phone so i could see for myself.
    Its a very expensive phone which is driving me crazy.

  • How to disable a button once it has been clicked

    Hi!
    I need to disable a button once the user has clicked it! I also need the colour of the button to change once it has been clicked as well (I need it to just grey out - not sure if this can be solved using actionscript??)
    The only method I could think of of accomplishing this is to put each button in their own UILoader, but I'm hoping there is a simpler method!?

    Here's what you do:
    1. Open the Components panel and drag a button on the Stage (do NOT create button symbol).
    2. For now, give it an instance name of "aButton" - that's what the code below uses. However, you probably want to use a different name. Also, you can open up the Components Inspector panel (CS4) to change the label on the button - use the Component Parameters section on the Properties panel if you have CS5.
    3. In the Actions panel use this code:
    aButton.addEventListener(MouseEvent.CLICK, disableButtonHandler);
    function disableButtonHandler(event:MouseEvent):void
         //do whatever (gotoAndStop, fscommand...)
         aButton.enabled = false;
    4. Test it. If it was done correctly (I tested it on my computer), the button should deactivate and go greyish when clicked.
    Make sure you use a Button Component. I don't know it this code would work with a Button or a MovieClip symbol.

  • New outputs generated when changing logical system in output master record

    Hi!
    We are sending documents from ECC 5 to a legacy system via XI/PI. We are about to move from an old XI installation to a new PI installation. The output record used (for example in a billing document) is set up based on logical system. When moving from the old to the new platform, we need to change the output records from the old logical syste to the new logical system. However this leads to generation of new outputs in all billing docs when opened in change mode. This goes also for billing docs where we already generated outputs via lthe old logical system in the past. Is there any solution to prevent the automatic generation of outputs for documents where the condition type already was successfully processed (as it works when the logical system is not changed)?
    Best regards
    /Björn

    Normally the same output is not supposed to be generated, unless 'Multiple issuing' checkbox is checked in the output type configuration.
    Also you can probably add a requirement in the output determination procedure and check if output record already exists. Take a look at the standard 'Reprint' routine, kind of the opposite is needed in this case.

  • How to find out if a table has been changed?

    hello
    how can I find out in a zreport, if a specific table has been changed and  data has been added or deleted?
    like for instance the date of last change to the table?
    thanks
    Alisa

    Alisa...you can do it following manner
    * Execute the report RSVTPROT to extract the changes done to database table
    * table with output going into memory
    TYPES: BEGIN OF ty_abap_list.
            INCLUDE STRUCTURE abaplist.
    TYPES: END OF ty_abap_list.
    DATA: gt_abap_list  TYPE STANDARD TABLE OF ty_abap_list.
      SUBMIT rsvtprot AND RETURN
        EXPORTING LIST TO MEMORY  USING SELECTION-SCREEN 1000
                                  WITH cusobj   EQ c_tabname "Table Name
                                  WITH dbeg     EQ gv_begdate
                                  WITH tbeg     EQ c_begtime
                                  WITH dend     EQ gv_enddate
                                  WITH tend     EQ c_endtime
                                  WITH objfirst EQ ''
                                  WITH tabfirst EQ 'X'.
    * Extract the list from memory
      CALL FUNCTION 'LIST_FROM_MEMORY'
           TABLES
                listobject = gt_abap_list
           EXCEPTIONS
                not_found  = 1
                OTHERS     = 2.

  • Conversion of logical system name fails

    Hi,
    when trying to transport a transformation on BW7 the logical conversion name is failing. When i check the setup (on rsa1 menu "Conversion of logical system names") it seams to be ok on source and target system.
    Any tips to solve this ?
    thx in advance

    Hi,
    when you are not maiantained the logical systems properly , then you will get that error when you are transporting the objects
    in Bi production system ( to which server you are moving objects) in that  you should maiantain the all logical systems as below
    1) for examaple BI deve --- BI prd
    one logical systm should be bi Dev to BI prd
    2) ECC production connected to BOI production
    Then one more logical assignment  ECC prd to BI prd
    normally those two you are maintained i think so.
    but when you are moving the objects from the BI development to Bi production
    the daat sources are pertaining to the ECC developmet
    so that ECC deve to BI Dev ( here there is no problem)
    when those daat source s you are moving to production it shows error
    because that ECC deve Data source logical system should be changed to BI production
    so you main tain one more logical system ECC dev to ECC PRD
    in your BI system
    Then try reimport the same.
    Thansk & Regarsd,
    sathish

  • Assign Logical System both in GTS and R3

    Hello all,
    We are using Two different system for R3 and GTS , and defined logical system both systems ( for R3 QR1CLNT100 and for GTS QG1CLNT100 , now do I need to assign logical system both system for clients in R3 and GTS ( I mean at the time of assignment both clients QR1CLNT100 & QG1CLNT100 i have to assign in both systems  or only one.   For Feeder system only I need to assign GTS system logical system as QG1CLNT100 vice versa ( for GTS system need to only Feeder system logical client QR1CLNT100)
    Thanks in advance for valuable inputs.
    Thanks & Regards
    Tarun

    There are following steps  for doing connection between R/3 and GTS
    1. Define Logical System
      Here you have to define both R/3 logical system as well as  
      GTS logical system.
    2. Assign Logical System.
    Here actually when u get in you will see the physical system
    detail on which you are logged in , suppose you are on R/3 you will find detail of R/3 system with different clients. Some clinet willcome as default like 00 which is waldrof client the SAP client and other are are those which are created at the time of installation.
    Here you have to assign the logical system of R/3 to the physical system client combination on which you looged in.
    you will find a field  of logical system on the top once you get in detail of the client system combination.
    Now here we have assigned the Logical system of R/3 this is required as when GTS will communicate wiht R/3 it willtry to look for  R/3 logical system as for RFC connection we always define logical system to which the system will talk.
    this configuration we do under Maintain RFC connection for RFC call Tcode SM59
    3.  Maintain RFC connection for RFC call Tcode SM59.
       Here we define the Target host, and logon detail like 
       language , client, user passwaord.
       We need to define the detail for GTS for RFC connection and   so we need here the logical system of GTS.
    4. Maintain RF destination for method call
      Here again you will require GTS logical system .
    5. Maintain ALE distribution here you will require both R/3 and GTS logical system.
    Hope it helps
    Kind Regards,
    Sameer

Maybe you are looking for

  • VF11 wrongly created with RV Doc type and with not clear status.

    Hi All Issue: There are 2 billing documents which were created(VF01) in March are canceled (VF11) in May. Cancel document is saved with a message (No automatic clearing of billing document XXXXXXXXX) and message diagnosis saying that u201CThe Automat

  • Can I change different background and font color on each records?

    Hi, I had a Data_Block which contains some records, I had a field name 'currency' which contains value such as (HKD, JPY, CNY, CND, USD etc..) Let there there are 5 Records contain in that Data_Block and I wanted to change the background and font col

  • Datatags, Error Handling, Formatting

    I've build JSP Pages on BC4J components using Datatags. I was wondering when applying DML changes how can i get write my own error code? Do I have the posibility to get the state of the attribute out of the datatags? Can i ask if the attribute is man

  • Report on column

    I want a report which on running will ask about a column of some table and then value of that column and display the data. say we have a table T and two fields f1 and f2. On running it should receive f1 or f2 as column names and then in the second pa

  • ABAP core book

    Hi everybody, can you please post that core book book to my gmail . [email protected] Thanks in advance