Problem to activate an append structure

Hi Guys,
I'm trying to activate an append structure for a specific extractor, bu the next error is raised
Activity terminated because errors occurred during package checks
and then, itis telling me to follow up the the next procedure:
Keep note of the setting for the package check (system-wide property) in your SAP System; this setting defines in which form the package concept is to be applied.
In particular, check whether the package in which the incorrect dictionary object is located has sufficient usage applications. Then, if necessary, create the missing usage applications.
As soon as the package check errors have been removed, you must again activate the dictionary object.
Please, any help is appreciated.
I.

Thanks Roberto!.
When I tried to enhance the extractor the system asked for a package and then to create a transport, but when i try to active it. it raised the error.
How Can I change the package o see if it is correctly defined?
I.

Similar Messages

  • How to activate the transparent table along with append structure

    Hi,
    I add the new fields in existing append structure on tale VBAP.
    Initially i provide them the data type as Char with length 20.
    Similarly i added the fields in user exit on scree 8459 to add fields on screen.
    Until this eveything was working fine.
    Then my functional consultant ask me to delete one field from structure and change the length of other data types to 40 characters.
    I done this changes but when i go to activate that append structure its giving me error that certan structures in which it is been used are not adjusted and activated.
    The table is not adjusted through SE14 - Database Utlity.
    Its showing me that Runtime Object and Transparent table are different and not consistent.
    Can i delete the runtime object?
    The domains which i ave changed are also not geing activated.
    Suggest me the node of problem and solution also.
    What should be the problem.
    What should i do to solve the problem.
    Suggest me the solution if any.

    Give a trail that instead of activating all together, activate low-level objects (domains, data elements etc)first and then high levels (structures, tables) individually. With this approach you could find the errors easily and can resolve quickly.
    Regards,
    Prasanth

  • Append structure activation

    hi all,
    we have got some problems while dealing with append structure.
    actually ,we tried to add some fields to the append structure of mara table ,
    then when activating it showed activation logs.so the table mara and the append structure to it is partly active.
    so is ther any way i can undo the changes so that the mara table and append structure gets activated becaise while undoing the changes ,it is also not allowing us to activate.
    kindly suggest any way out.
    thanks

    hi
    once u add the fields in the structure & then when u append that in the database table ., then u have to adjust the database for the table.
    gotto se11... give ur table name ..diaplay..then utilities..click on database uitility, then at the bottom of the screen there is a push button "activate & adjust database"..
    clcik on tht button... table will adjusted for mass activation..
    try & let us know,,,
    reward points if it is useful..
    thanks,
    Manjunath MS

  • Append Structure for Table

    Hi All,
    I have added an append structure to a table in SE11. While adding the append structure i opened the table in display mode and added the append structure. I have also activated the append structure.
    But in my transport request i can  only see the append structure and not the original table. Is it safe to transport such a request ?

    Hello,
    When you're APPEND'ing a table you're not modifying the original table.
    You are linking the APPEND structure to the original table & the linkage is maintained in the APPEND structure(see the "Attributes" tab of the APPEND structure).
    Yes, the original table gets activated & adjusted when you activate the APPEND structure but it won't ask you for a TR. Whenever the TR is imported to the subsequent system the original table will automatically get activated & adjusted.
    Hope i'm clear. You can read the F1 documentation on APPEND structures for further info.
    BR,
    Suhas

  • Package check Error while activiating Append Structure

    Hi All,
    I have created an Append Structure for the Table HRP5136. When i am trying to activate the Append Structure the error "DDIC object TABL ZZHRS_EXTENDOFFER has package check errors" is thrown.
    How do i resolve this? Any input on this will be of great help.
    Thanks very much for your time
    Regards,
    Pavithra

    Hi,
    You r doing enhancements to the table .
    when ever u do any changes u need to give the package name.
    So find the package name of that table as follows.
    In the tables screen itself click on system-> status .
    there u will get the package name . give that name when u r activating the table.
    Reward If Helpful

  • Getting Error in Append Structure for Standard

    Hi all,
    Here i want to Append Structure in table RFPOS so i done all procedure . in this i have four field like ZZKUNNR , ZZNAMED , ZZLIFNR, ZZNAMEK. But when i active this structure this time i get error like
    "Field name INDEX is reserved (Do not use structure as include in DB table)"
    and
    "Field name ORDER is reserved (Do not use structure as include in DB table)"
    BUT structure is activated . now i can see my change in fbl3n T-code so i get proper change in this.
    But when i transport a request in Quality this time i am not getting same output which i get in Development .
    And yes request is transported with warning (YELLOW SIGN). So is it possible for this warning i am not geeting my proper output in FBL3N.
    Please kindly help me out
    Thanks
    Keyur

    Hello,
    Did you do anything else also that you might have missed to mention here?
    For example, was your Append structure already present in the table RFPOS & you deleted some of the fields & inserted the new ones. In this case, you might have to activate the table from database utility (transaction SE14).
    If this is an append structure & if it was pre-existing (not created by you), then this structure might already had been assigned to any other table. In such a case, system will not allow you to directly assign it to a different table. You may have to first assign it to an INCLUDE structure.
    Also, as you described, it indicates that there might be some problem with the fields named INDEX & ORDER. Try checking for it.
    May be you should check with your BASIS guy if the transport was successful & if not, the error description.
    Also, try checking the quality system for your changes.
    Hope that helps you in getting some direction.
    Let me know if that work out for you or not.
    Regards,
    Saurabh

  • Append structure -- to structure

    i made append structure to cekko and it's weel done i get zacekko.
    the problem is:  i want to delete the zacekko , how i can do it?
    what the steps..?

    1. Goto se11
    2. enter your append structure name.
    3. press delete
    4. It will delete this append,
    also in the original table/structure
    where it is used, AUTOMATICALLY.
    ******************************8
    or
    Select that structure and click on the '-' icon which will delete
    then goto SE14 , Adjust and Activate that table

  • Append Structure in Standard Table

    Hi Gurus,
    My problem Is:---
    I create an Append Structure on Standard Table..it create successfully..but after it, when i want to activate the standard table, it gives errors....
    Not standard table is partially active...
    I want to reverse it back...how it is possible....
    My Solution:.. I try my besy through SE14...there I give the Table name and click on EDIT...
    there i click on Activate and Adjust Database...but there it gives errors....
    Append structure ZMARC11 appended to table MARC
    Current enhancement classification 'enhanceable and numeric or char.type' is incorrect
    The following enhancement classifications can be selected:
        'Can Be Enhncd(Deep)'
    Field MATNR in table MARC is specified twice. Please check
    Field MATNR: Reference MATNR to class w/o interface cannot be used in DB table MARC
    Field MEINS: Reference MEINS to class w/o interface cannot be used in DB table MARC
    Attachment of search help MAT1 to field MARC-MATNR is deleted
    Activation of Table MARC not possible (please check)
    Request for MARC could not be executed..
    Plz. Help....

    Hi,
    I know the fields name...
    MARC-MATNR...and MARC-MEINS...
    How can i revert back....
    Plz Help...

  • Can not store data to append structure in mara

    Hi
    after make the following steps, I have problem, please give me some tips. thanks
    1, Append structure Zcode in MARA.
    2, Created a ZMGD1 via SE80 copy from function group MGD1.
    3, modify screen 0001, put this Zcode in this screen and FC MARA-Zcode.
    4, change SPRO, specify new program SAPLZMGD1 for this screen 0001.
    after these steps, I can find out this new field (Zcode) appear in MM02.
    but, the data of Zcode can not be store in MARA.

    Hi:
    the exactly problem is I don't know how to read this screen field value, and how to transfer to wmara-Zcode.
    anybody can help me?
    thanks
    Henry

  • What is diff b/w Include Structure and Append Structure at Database Level

    Hi Experts,
    Could you please let me know what is the main difference between .Include Structure and .Append Structure at SE11?
    Thanks in advance and for good answer will give good points.
    Sekhar

    Hi,
    1. Append Structures
    Append structures can only be assigned to a single table.
    Append structures are created in the custome rnamespace ( ZZ or YY)
    In case of new versions of the standard table during upgrade, the append structures are automatically appended to the new version of the standard table
    Append structures can not be used with cluster and pool tables
    Append structures are created in transaction SE11. Display the standard table fields and press the Append structure button.
    When you press the button, SAP sugests a name for the new append structure. After you has accepted the name,
    a screen will be shown where you can enter the new fields.
    Remember to activate.
    2. Customizing Includes
    Some of the SAP standard tables contains special include statements called Customizing includes. In contrast to Append structures,
    Note that customizing includes are created by SAP, but the customer supply the fields for the include.
    Customizing includes begin with CI_ and is part of the customer namespace
    One Customizing include can be inserted into more than one table.
    You can find Customizing includes in SE11 under structures.
    Try to take a look at table RKPF which uses the Customizing include CI_COBL (In an IDES system). Next try to add a field to CI_COBL, and activate it. If you go back to table RKPF you will se that your new field has been added.
    Regards,
    Ferry Lianto

  • Appending structures to fbl5n

    hi people. .
    I created a struct:ZINV_FBL5N with 4 fields and need to append them to RFPOS structure and RFPOSX structure.
    But when i try to do i get the error that the struct already exists. Also while creating the structure I have not used data element as shown in the pics below.
    Please guide.

    Hi,
    You first created the structure ZINV_FBL5N and then tried to create append structure. Actually, you should have done the following things. Firstly, you should press append structure;  then create; give a name to the structure; add the fields and activate the structure. The new fields added would then reflect in RFPOS and RFPOSX structure. In your case, system issued a message because you created the structure, and then tried to create append structure with the same name.
    The standard way of adding customized fields to append structure is to create a structure,say ZABC add the fields. Press append structure, create an append structure with different name ( name starts with ZZ* or YY* ) and then add the structure ZABC using  .include ( include structure from the menu )
    e
    Regards,
    DPM

  • Append structure

    hi ,
    i am getting an error message while am creating an append structure.
    what i have done is ..
    i created a structure in SE11 with 4 fields with name zstruct .
    and i have one ztable with 5 fields. when i am trying to append  a structure through Append Structure button , system is asking for the name of the structure.
    here is my problem...
    when trying to giving the structure name which i was created earlier ie., zstruct, it giving error that " structure name is already created."
    can any please help me in this regard.
    cheers,
    srak.

    hi..
    u cannt append the structure with the same name as it is already created.....
    u have to give the different name and thier u specify the field names....
    the u r table will get appended  with the new fields...
    hope it works...
    thanks
    sam

  • Package Check Error while activating the Appended Structure

    Hi CRM Gurus,
    A structure is appended to a standard structure. while activating the appended structure its throwing Error called-
    <b>Package Check for Table/Structure ZCDPR_BW_BUPA_LINKS</b> .     
    <b>The object TABL ZCDPR_BW_BUPA_LINKS uses SQLT DPR_BW_BUPA_LINKS</b>.
    plz help me to get the solution in this regard.
    Regards,
    Gokila

    Hi
       were you able to solve your problem?
       If so please update us. We are also facing same issue while activating the table.
       let us know the solution if you have solved the problem that will help us a lot.
    Thanks and regards,
    Amit

  • Error while appending structure into BSEG Table

    We had appended BSEG table with a ZSTRUCTURE to enable Custom field in MIRO. Subsequently there was a change required in the appended field. After Changing the field there was adjustment required to activate the appended table . However due to slow system performance during that time the Adjustment SE14 timed out. And created inconsistency in BSEG table.
    If I Do the Table adjustment now it is showing below error.
    We tried to delete the append structure also but the structure is not appearing in the append structure list to delete.
    Even if we try deleting the Z structure from se11 it is throwing below error.
    Any one could help me out to resolve this..

    hi Ramesh,
    Please First Check if the Database version and disctionary version are in sync.
    Also, it could be the case that you would have enhanced an already existing Append stucture. which might be being used in other BKPF dependent tables.
    Please check

  • Customer Master using Appended structure KNA1

    Hi
    We have to update few ZZ description fields in ZAKNA1, which are not part of user interface in XD01/02/03. The available options are such as LSMW, Batch input require code addition through user exit ZXF04U01/ EXIT_SAPMF02D_001.
    I would like to use BAPI as we have a plan to use web services. Any idea how to extend the BAPI's such as BAPI_CUSTOMER_CHANGEFROMDATA1 or BAPI_CUSTOMER_CREATEFROMDATA1 using best practice?  I donu2019t find any extension structures like other BAPIu2019s have. Without ExtensionIn and ExtensionOut parameters, a BAPI can not be enhanced correct?
    The version we are using is ECC 5.0. Any ideas with customer master BAPI will be greatly appreciated.
    Bala

    Hi Bala,
    Just some general comments without having looked at your specific problem. Since you're on ECC 5.0 you cannot use the new [Enhancement Framework|http://help.sap.com/saphelp_nw2004s/helpdata/EN/94/9cdc40132a8531e10000000a1550b0/frameset.htm], which would make such changes more easy...
    A rather awkward workaround for extending the BAPI's is sometimes to add append structures to an IMPORT parameter of the BAPI. However, this is a rather dangerous and limited approach, because you might get into trouble depending on where the structures are used (i.e. if you add a field, it might cause harm in other programs that use the structure) and you also have to study the source code to see if you even could utilize those additional fields.
    A pretty generic option in lieu of other approaches is to generate a custom wrapper function module around the standard BAPI. Within your custom BAPI you can add the missing fields as parameters, call the standard BAPI and then do the additional updates. The big advantage of such a solution is that
    <ol>
    <li>Your change/additional logic is obvious (not hidden in a customer exit or BAdI, which are often harder to find when troubleshooting or changing functionality)</li>
    <li>Any changes to the standard BAPI will automatically also take effect in your custom BAPI (since you didn't copy the original one); this excludes of course interface changes, but here you anyhow would have to do something...</li>
    </ol>
    Should you have custom fields that are already exposed on the customer maintenance screens via enhancements, then you might want to consider using the wrapper approach, but simply export the additional data to memory, then call the standard BAPI and within the customer/user exits handling the additional fields fill them via an import from memory.
    Cheers, harald

Maybe you are looking for

  • Can't see purchased music, movies, or TV shows after upgrade to iTunes 11.1.2

    I upgraded my Macbook to the new Mavericks OS and also updated iTunes to the newest version 11.1.2 on Wednesday. Since then I have been unable to view any of my purchased music on the iTunes Store. The purchased page comes up blank. However I am able

  • Auto-remount of root file system, like read only

    Hello, I'm a newbie compiling kernels, but wanna learn. (I came here bacause i don't know how to solve this or where to find an answer).  I compiled some few... but, in the last days i'm suffering an strange auto-remount of the root fs "/", (remounts

  • IC webclient -help...............

    Hi experts,              The following is a code of standard IC webclient  . <crmic:gridLayoutCell columnIndex="1" rowIndex="<%=lv_r5 %>" colSpan="3"><crmic:label design = "label"                      id = "AccountNo"                      for    = "/

  • Trophy:Back button activation area not as wide?

    i dont know if its supposed to be designed this way but with my back button i have to push the screen/button about 1mm from the left side of that arrow. but with the search button i can push/activate from the area about 3mm on the right of the image.

  • Perhaps same display problem...

    my wife was complaining lastnight that her ibook was locking up and doing "wierd screen things", so i let her use my powerbook adn went back to sleep. this morning, i was looking at her ibook, and here's what i found. after a minute or two after boot