Problem with Local Currency field in PIPE monitor

Hello, We have configured PIPE in BW and sent idoc WPUBON (sales) there.
But the task u2013 u201CSupply to BW immediatelyu201D are failed :
The error message is :
"Field Local Currency does not have a value (initial).
System Response
Current processing requires the field to be enriched within the master data checks.
Procedure for System Administration
Check Customizing for the master data checks."
My question is if the problem are reffered to PIPE configuration problems or BW master data downloading ?
I didnu2019t find this field anywhere in /POSDW/img. Maybe this is BW master data problem?
But I am confused the phrase u201CCustomizing for the master data checksu201D . Is it still the PIPE cutomizing problem?
Where is the "Customizing for the master data checks"? What does it mean?
Thank You.

Hi
Can any one please tell me do you have any solution for this. I am getting problem in quality box.
Regards
Mark

Similar Messages

  • Problem with non currency field calculations to become curr

    Hi guys,
    Is there a problem if I have a QUAN field and DEC field forming to become a CURR field? I mean a have this computation below:
    v_var1 = v_var2 * v_var3.
    where v_var1 type QUAN, v_var2 type DEC and v_var3 type CURR...
    would it incur any problem with the calculations?
    Thanks!

    Hi,
    Did you try ?
    Worked for me flawlessly
    tables bseg.
    parameters : qty like bseg-menge,
                       amt like bseg-dmbtr.
    data : result like bseg-dmbtr.
    result = qty * amt.
                write result.
    The only issue is that the result will be rounded upto 2 decimals.
    But if you declare result as
    data : result(13) type p decimals 3.
    Then there will be no issues.
    regards,
    Advait
    Edited by: Advait Gode on Oct 3, 2008 3:59 PM

  • Problem with a Currency field in Adhoc Query - HR

    Hi,
    I have an Adhoc query that uses Custom infotype fields (Z infotype and z fields).
    The currncy field also has a reference field in the infotype (of type waers).
    Wehen we try to get the ouput of the Adhoc Query it gives following error:
    The report cannot be generated because the internal description is invalid or incomplete, or because the selection screen is too large.
    Regenerate the assigned InfoSet, and read the log. If the InfoSet is OK, make sure that at least one field is given as output.
    If you used the 'Refresh' icon to start the query, use the 'Output' menu option to execute the query. This gives you a full screen display of the data.
    If an output was generated, the query cannot work with actual data in the construction view. In this case, always use the 'Output' function to execute the query.
    I have already tried a number of solutions:
    1> Regenerate the infoset...
    2> make the field as an additional field and write my own code for it (the error comes before the code as i kept a breakpoint but it stopped before that)
    if i add other fields of this infoset instead of this field, then those appear in the output.
    Any solutions ??
    thanks in advance,
    Anuj

    Hi,
    Is the problem not clear or no one has an answer?
    Please reply with some suggestions..
    Regards,
    Anuj.

  • Problem with the currency fields in the table cdpos

    Hi Gurus,
           I have observed one thing with the cdpos table like whenever we made changes to the currecy( and numeric fields also ,i am not sure ) fields ,then in the cdpos table it is showing a new entry for that change but not showing that old value, why? .But when we made any changes to date fields ,then it is storing that old date.
    So Is there any specific feature in this table.
    Thanks & Regards,
    Rakesh.

    Hello
    In ABAP-programm try this:
    DATA:       NEW LIKE CDPOS-VALUE_NEW,
          OLD LIKE CDPOS-VALUE_OLD,
          NEW1 TYPE MENGE_D,
          OLD1 TYPE MENGE_D.
    FIELD-SYMBOLS: <f> TYPE ANY.
    * make select from CDHDR and CDPOS
    IF CDPOS-FNAME = 'MENGE'.
      MOVE CDPOS-VALUE_NEW TO NEW.
      MOVE CDPOS-VALUE_OLD TO OLD.
      ASSIGN NEW TO <f>.
      CATCH SYSTEM-EXCEPTIONS CONVT_NO_NUMBER = 2
           OTHERS = 4.
           NEW1 = <f>.
      ENDCATCH.
      ASSIGN OLD TO <f>.
      CATCH SYSTEM-EXCEPTIONS CONVT_NO_NUMBER = 2
           OTHERS = 4.
           OLD1 = <f>.
      ENDCATCH.
    ENDIF.
    After this in NEW1 and OLD1 you will see values.

  • Problem with Group Currency

    I looking for help!!
    We do a initial loading of financial postings with LSMW. We had a big problem!!
    The postings were made without the amount at the group currency.
    Now we show it at the reports of Controlling, too late for change the postings.
    We need a solution for change this without do a new posting. Someone can help us?
    The values at the local currency ARS are correct, we have just the problem with the group currency EUR.

    IF the posting were made with out group currency, There is no way you will get the group currency. What you need to do is just load the balances in group currency using the tcode FBB1 and leave document and local currency fields zero.
    Assign points if helpful

  • What is second local currency fields used for?

    Hi experts,
    Please tell me what is the this second local currency fields like DMBE2, BDIF2, MWST2, present in BSIK, BSAK fields.
    Thanks,
    vinay

    A Company Code can be setup more than one Local Currency. For instance, many organizations will setup the Company Code for operations located in Singapore with a Local Currency of Singapore Dollars (SGD). But, they will also set it up with a Local Currency 2 of US Dollars (USD), because Singapore organizations often do trading business in US Dollars. Therefore, when an FI transaction is posted, all identified Local Currency values will be updated to it (there's also a Local Currency 3 too, but it's rarely used - if I recall it was initially setup for EU companies when transitioning to the EURO).

  • Problem with local editing after update to SP13

    Hallo,
    we have updated our Enterprise Portla 7.00 to SP13. Now many user have Problem with local editing. The error message is "The download of the document fail".
    I know that every PC needs the "Docservice" Active X component installed. The "Docservice" is also installed.
    At my PC theres only this problem with "html" documents.
    What could be the problem. ?
    Please help.
    Many thanks
    Ronald

    We found that there is a problem with the Docservice Active X Component.
    If we work in a deeper folder there is a problem with the length of the url. I changed the TEMP Setting
    "Setting a different TEMP directory:                                     
    In cases that it is problematic to use the standard %TEMP% directory,   
    setting the environment variable SAPKM_USER_TEMP pinpointing to a       
    corresponding directory path (e.g.                                      
    X:\SHARES\USERS\xxx\CheckedOutDocuments) will be also supported. If the 
    access to that directory fails the standard %TEMP% directory will be    
    used as fallback."
    I used "C:\TEMP" and now it works.......  but this cant be the solution....
    thans Ronald

  • Problem with Local Intranet in IE 11

    Hi
    We are experiencing a strange problem with Local Intranet in IE 11. We have a public company site which has been put into the Local Intranet site. The site contains content from 3 internal sites, which of course are part of Local Intranet per default.
    Sometimes when I refresh the public company site I receive a security warning because IE says it's between zones.
    Why? :-)
    Might this be an issue because the 3 internal sites aren't hardcoded into Local Intranet through policy?
    Lasse
    /Lasse

    Hi Lasse,
    I would like to know if this issue happened in all user's IE browser.
    Meanwhile,please post the screenshot here
    so that we can help you analyze the issue.
    Regards,
    Kelvin Xu
    TechNet Community Support

  • Problem with Local DCs View in NWDS 7.0

    Hi!
    I' ve got a problem with Local DCs view in NWDS: None of the standard-DCs (BI_MMR, BI_UDI, CAF a.s.o.) can be expanded and show their content. I already reinstalled IDE, but without success.
    Has anybody got an idea?
    Thanks a lot in advance!
    Regards,
    Thomas

    Hi,
    This is due to some files missed in Local development.
    Let me know Are you able to see <b>.confdef, .syncdb</b> and <b>buildvariant.config </b> files under Local Developement.
    If you are not able to see, UnInstall your NWDS, Remove Local developement under .dtc folder, then Re-Install NWDS.
    Hope this will help you.
    Thanks & Regards
    Vasundhara

  • Problem with Local DCs View in NWDS

    Hi!
    I' ve got a problem with Local DCs view in NWDS: None of the standard-DCs (BI_MMR, BI_UDI, CAF a.s.o.) can be expanded and show their content. I already reinstalled IDE, but without success.
    Has anybody got an idea?
    Thanks a lot in advance!
    Regards,
    Thomas

    Your setup might be incomplete: The SAR file extraction creates very long paths on your filesystem. If you do not extract to the rootfolder of disk, chances are the paths become too long and the installation exits, without any warning.
    If this is not the cause of your problem, check if the .dcdef files for the local DCs (plugin com.sap.tc.ap if I'm correct) were copied during installation.

  • Problem with a Dynpro field (type numc)

    hi everybody.
    I'm developping a ModulPool application in wich i have 2 RadioButtons with 2 textbox fields.
    What i pretend to do is, when the user clicks a radiobutton and strikes Intro, enable the corresponding textbox field and disable the other one.
    My code runs fine, but i have a little problem. When I loop the screen table, to set the appropiate value to the 'input' property, in this case, when i try to disable it (input = '0'), I get a zero character in that field. This field has NUMC type, i'm sure this is the problem
    'cos i've got no problem with the other field (type char). But i can't solve it.
    Anybody's got an idea?
    Thanks

    What you are seeing is the normal behavior of a numeric field represented by the SAPgui.  This is how all numeric fields are displayed via SAPgui.  If you don't want to see the 0,  then you just change the field type to CHAR and handle accordingly.
    Regards,
    Rich Heilman

  • Problem with the quantity field

    hi every one
    i am facing a problem with the quantity field (vbap-kwmeng)
    as per my requirement i need to display this quantity field along with some other item fields from VBAP in an alv grid.
    among all the fields displayed in the alv grid only this quantity field is editable(end user can change this quantity)
    once end user changes this quantity and press save button i need to capture this new quantity in my internaltable.
    problem is input of length of quantity is 15 and the output length is 19
    so when i am pressing save
    say my quantity is 50 when i am pressing save '0.050' is coming because of the length difference
    how can i capture the original changed value.
    vamsi

    what about define two fields in  you inner table ,one as char and the other as vbap-kwmeng, you can show the char one in the ALV gird , when user input value and press SAVE ,you can move the value to vbap-kwmeng.
    you can test it,mybe some one has one better idea.

  • Problem with adding new field to the mass change screen in FBL5N

    Hi,
    We have a problem with adding the field XREF3 to the mass change screen. We followed steps described in the SAP Note 640908, but the result is that when we try to mass change some documents in FBL5N and enter some values in the mass change screen, a message appears: "Please enter at least one new value" and nothing is changed.
    If you have faced with such a problem, we would be grateful if you give us some tips.
    Regards,
    Miłosz Włodarczyk

    The problem has been resolved: we didn't activate a code in SE80.

  • Amount in Local Currency Field not showing up under PO history tab

    Hi Freinds,
    I have faced a strange situation where one of the Business user can see the field Amount in Local currency under PO history tab , however the other user can not see this field.
    When the second user( who can not see this field) checked for the Layout Settings, the field Amount in Local currency is not present there also.
    Kindly guide me what needs to be done for the second user to be able to see the needed field.
    A quick reply will be highly appreciated
    Thanks& Regards,
    Anshul

    Hi Jain,
    The issue was realted to authorisation, if you have chekced the layout and it doesnt concern the layout settings then ask BASIS to provide authorisation to the user who is not able to see amoutn in local currency field under PO History tab
    Cheers,
    Anshul

  • Problem with locale

    I have a problem with locale.
    When I put the locale command in the console.
    This is the output:
    locale: Cannot set LC_CTYPE to default locale: No such file or directory
    locale: Cannot set LC_MESSAGES to default locale: No such file or directory
    locale: Cannot set LC_ALL to default locale: No such file or directory
    LANG=en
    LC_CTYPE="en"
    LC_NUMERIC="en"
    LC_TIME="en"
    LC_COLLATE="en"
    LC_MONETARY="en"
    LC_MESSAGES="en"
    LC_PAPER="en"
    LC_NAME="en"
    LC_ADDRESS="en"
    LC_TELEPHONE="en"
    LC_MEASUREMENT="en"
    LC_IDENTIFICATION="en"
    LC_ALL=
    Whats the problem?

    Here's mine, just for comparison:
    locale.gen
    en_GB.UTF-8 UTF-8
    en_GB ISO-8859-1
    en_US.UTF-8 UTF-8
    locale.conf
    LANG=en_GB.UTF-8 UTF-8
    Output of locale:
    LANG=en_GB.UTF-8
    LC_CTYPE="en_GB.UTF-8"
    LC_NUMERIC="en_GB.UTF-8"
    LC_TIME="en_GB.UTF-8"
    LC_COLLATE="en_GB.UTF-8"
    LC_MONETARY="en_GB.UTF-8"
    LC_MESSAGES="en_GB.UTF-8"
    LC_PAPER="en_GB.UTF-8"
    LC_NAME="en_GB.UTF-8"
    LC_ADDRESS="en_GB.UTF-8"
    LC_TELEPHONE="en_GB.UTF-8"
    LC_MEASUREMENT="en_GB.UTF-8"
    LC_IDENTIFICATION="en_GB.UTF-8"
    LC_ALL=
    Have you also run the command sudo locale-gen?
    Last edited by clfarron4 (2013-09-04 00:04:26)

Maybe you are looking for

  • Unable to load XDB library

    Hi, i have just created a new database but i keep getting the following error ORA-00600: internal error code, arguments: [unable to load XDB library], initializing SGA: sga_pass1Dynamic link error: Could not load module /u03/app/or acle/product/10.2.

  • BW Statistic reports has 'VIRTUAL-00001' entries

    Hi all; I ran a BW stat report which comes from BW stat multiprovider, to see what are the reports that were used for last year and I got some entries with report name VIRTUAL-000011 VIRTUAL-000016 VIRTUAL-000006 Also I have on entry with just letter

  • Is my Mac good enough really?

    I think that I have the minimum Mac requirements for FCE HD. Does anyone out there have a mac similar to mine that can attest to FCE HD working properly or you being able to use all of its functions/ options? Thanks for the feedback (in advance), Jos

  • Lost/stolen iPod - Can you track serial number to current owner/thief?

    Recently I have either lost or had my iPod stolen while traveling across country. I had a brand new 30GB - Black iPod that disappeared from Point A to Point B. I took a red-eye, so either could have easily happened given the delays, weather condition

  • Air app limitations . . . ?

    Hi there. Two questions. Is there a file size limit to an Air application and is it possible to add around 12,000 audio files in one go? On the Air Application and installer setting you can only add included files one by one. Is there any way to sele