Problem with numeric screen field....
hi,
I've gotta situation that,
In sales order we gotto determine WBS element(ps_psp_pnr) based on some conditions, if none of the condition is satisfied then the 'project definition'(prps-pspid) has to be concatenated with '.99' and displayed as WBS element.
Now the actual problem is, WBS element is of numeric character type whereas the projectdefinition(pspid)+.99 is of charcter type. So it throws me a dump. Even then, the screen field of WBS element doesnt shows any non numeric character and shows error message.
So how do i overcome this situation? Can anyone help me? Its quiet urgent.
Prompt answeres will be rewarded with points.
with regards,
praveen.
Hi Praveen,
If you take SE16 and PRPS, you can see how SAP store it internally and show externally. In the first screen where it shows the line items, the WBS element value is the one stored internally and if you double click and see the WBS value in the next screen it is the one showed in the transaction screen.
For the conversion routine, even if the parameters are type less, you have to pass the variable with type.
For example
data: w_POSNR type PS_POSNR,
w_wbs(8).
w_wbs = '123.55'.
CALL FUNCTION 'CONVERSION_EXIT_ABPSP_INPUT'
EXPORTING
input = w_wbs
IMPORTING
OUTPUT = w_posnr
EXCEPTIONS
NOT_FOUND = 1
OTHERS = 2.
IF sy-subrc <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
Similar Messages
-
Problem with adding new field to the mass change screen in FBL5N
Hi,
We have a problem with adding the field XREF3 to the mass change screen. We followed steps described in the SAP Note 640908, but the result is that when we try to mass change some documents in FBL5N and enter some values in the mass change screen, a message appears: "Please enter at least one new value" and nothing is changed.
If you have faced with such a problem, we would be grateful if you give us some tips.
Regards,
Miłosz WłodarczykThe problem has been resolved: we didn't activate a code in SE80.
-
Problem with a Dynpro field (type numc)
hi everybody.
I'm developping a ModulPool application in wich i have 2 RadioButtons with 2 textbox fields.
What i pretend to do is, when the user clicks a radiobutton and strikes Intro, enable the corresponding textbox field and disable the other one.
My code runs fine, but i have a little problem. When I loop the screen table, to set the appropiate value to the 'input' property, in this case, when i try to disable it (input = '0'), I get a zero character in that field. This field has NUMC type, i'm sure this is the problem
'cos i've got no problem with the other field (type char). But i can't solve it.
Anybody's got an idea?
ThanksWhat you are seeing is the normal behavior of a numeric field represented by the SAPgui. This is how all numeric fields are displayed via SAPgui. If you don't want to see the 0, then you just change the field type to CHAR and handle accordingly.
Regards,
Rich Heilman -
Does anyone has a problem with the screen of the new ipad? (there's a part of the screen which the color in it is "very" bright) and when I move the aluminium part of the smart cover when it's attached to the ipad the colors change!! Help!!!
I'd take it into my local APple store and have them look at it. There may be something wrong inside your device.
-
Problem with Variable screen in WAD
Hi ,
I have a problem with variable screen in WAD , in the varable seen it is displaying only Key , it is not giving any description , but in BEX is is displaying both Key and Description , can any only have an idea why is this happening . this is occuring only for one variable , rest are working fine .
Thanks,
AbrahamHi Abraham,
thsi could be a problem from the specisic setting of the infocube. Please check the BEx Settings from the infocube. You can find them by the following steps:
- search for the infocube
- doubleclick on the infocube
- choose an specific infoobjekt
- right mousebutton and click "specific dataprovider settings"
- check if the right entries are set
Hope this will help.
André -
Problem with sub-screen actions on Cancel button
Hi all,
I have a problem with sub-screen.
I created a subscreen (screen sequence in MM01/MM02/MM03). When users leave this screen, I call POPUP_TO_CONFIRM to ask if they want to save the data.
1) My goal is: when they choose Cancel, no actions are performed and users will see the current screen. However, I cannot use command: SET SCREEN 0 or LEAVE TO SCREEN 0 because the system gives an error message:
*SET SCREEN not allowed in subscreens*.
2) How can we determine when the user leaves the screen? which value of SY-UCOMM will be used to check this?
Thanks in advance.for dis SET SCREEN is not required.
Consider d code given below as n eg:
CALL FUNCTION 'POPUP_TO_CONFIRM'
EXPORTING
titlebar = 'SAVE'
text_question = 'SOME _QUS'
text_button_1 = 'YES'
text_button_2 = 'NO'
default_button = '2'
display_cancel_button = ' '
IMPORTING
answer = l_ans
EXCEPTIONS
text_not_found = 1
OTHERS = 2.
IF sy-subrc <> 0.
MESSAGE e066.
ENDIF.
IF l_ans EQ '1'. " when yes is pressed
MODIFY db.
commit work.
leave program.
ELSEIF l_ans EQ '2'. "when no is pressed
leave program.
ELSE. " when cancel is pressed
ENDIF.
In above module when Yes is pressed it saves data den leave prog.
As no action is specified for cancel button it will remain on that screen only from which popup is called, in this way ur problem can be solved.
Reward properly. -
Not sure if this is the correct forum.
Okies, a user of mine has a problem with her SAP screens. It seems that she can't view the full screen of CJ20N She has to drag the window bigger to be able to see the content. She uses this window in a split monitor view, i.e. some of the applications are displaying on the laptop window while other applications display on the monitor.
Details of her SAPGUI:
Release 640 Final
File version: 6404.4.16.1015
Build: 774474
Patch Level : 16
Do note that her primary monitor (notebook) is always set to 1280x800 and the secondary monitor is set to 1024x768. Anyone encounter this problem before?Hi,
This is problem with windows screen resolution. Better to use, maximum supported window size and make sure to use same size for both the screens.
Regards,
Ganesh -
Problem with matrix/screen in Qosmio F55-Q502
Hello
For a few weeks I have strange problem with matrix/screen in my laptop.
The matrix flickers very often - no matter if power cable is plugged or not.
The screen is full bright and suddenly it starts to blink - it is getting darker, than lighter, usually for few/dozen seconds. It does it when nobody touches it or when I work on it.
It very annoying and making eyes tired - it does it very quickly and there are few levels of screen brightness.
Moreover sometimes the screen turns off - You can see what is on desktop but the screen is very very dark (but not blank or completely switched off). It happens without any reason - sometimes just in the middle of working, sometime for example when I touch (not pull) the power cable between laptop and power supply.
Then, the only way to get back to normal brightness of screen id to close the lid just for half a second and open it
- matrix lights then normally, but can "turns off" moment later and I must do it once again - sometimes even few times..
After "action" with lid screens seems like nothing ever happen..
Does anyone have idea what is the cause of such behaviour or how to diagnose it in details?
Or maybe solve this problem?
Best regards
300mSounds like the Backlight or Inverter is failing or there is a loose connection.
Is the unit under warranty? Send it to an ASP for repair.
You should avoid repairing it yourself, the backlight is very high voltage! -
X220:Graphics problem with full screen videos
I have got my X220 laptop last month. I am facing problem while playing youtube videos full sceen.
videos can be seen best with smaller window but there is major graphics problem with full screen.
Can someone help on this?
I am using Windows 7 Enterprise edition.
Thankswhat do you mean by major graphics problem, please elaborate.
Regards,
Jin Li
May this year, be the year of 'DO'!
I am a volunteer, and not a paid staff of Lenovo or Microsoft -
Ok I am getting problems with full screen graphics on some computers.
I am writing an internet based RPG and this is really eating into my time...
Can any one explain why my graphics will not show some times (works others) with the exact same code running....
I am using a BufferStratagy with a frame.
Any help would be gladly apreashiated thank you in advance,
PhibredNot a thread issue, no thread on this side of the program and yes there is a media tracker. However I have learned that my problem was that my screen does not like to flip to 800x600 for java applications for some reason thx any way.
-
with the new IOS 7 mi iPhone has problems with the screen, I go out once stripes, and Apple told me it is the software. help when there is a new update?????
We are users here. We cannot possibly know when a new update will be available.
-
Problems with share screen in lion
Hello
I have had problems with share screen since i have installed Lion. I can't share screen even inside the Lan, between Macs and between Mac and Iphone. It's like Lion would had some port block in any hidden place. Anyone knows something about it?FINALLY! Got Screen Sharing to work! REPLACE ARDAgent (v3.5.1) with the older v3.4
Instructions by tchaga:
1. Download ARD 3.4 (http://support.apple.com/kb/DL1350 RemoteDesktopClient.dmg), mount it, look inside the package/Contents, copy the Archive.pax.gz to the desktop
2. Expand the Archive.pax.gz and navigate inside the resulting folder Archive to /System/Library/CoreServices/RemoteManagement
3. Navigate to the same folder at the root of your HD (i.e. HD/System/Library/CoreServices/RemoteManagement)
4. Copy ARDAgent from your HD/System/Library/CoreServices/RemoteManagement to the Desktop and then delete it from the HD/System/Library/CoreServices/RemoteManagement folder (you need admin password).
5. Copy ARDAgent from Archive/System/Library/CoreServices/RemoteManagement to HD/System/Library/CoreServices/RemoteManagement (you need admin password again).
6. Restart -
Problem with the quantity field
hi every one
i am facing a problem with the quantity field (vbap-kwmeng)
as per my requirement i need to display this quantity field along with some other item fields from VBAP in an alv grid.
among all the fields displayed in the alv grid only this quantity field is editable(end user can change this quantity)
once end user changes this quantity and press save button i need to capture this new quantity in my internaltable.
problem is input of length of quantity is 15 and the output length is 19
so when i am pressing save
say my quantity is 50 when i am pressing save '0.050' is coming because of the length difference
how can i capture the original changed value.
vamsiwhat about define two fields in you inner table ,one as char and the other as vbap-kwmeng, you can show the char one in the ALV gird , when user input value and press SAVE ,you can move the value to vbap-kwmeng.
you can test it,mybe some one has one better idea. -
I am looking for anyone in the west Tennessee area using Wild Blue along with Apple IMac who is having a problem with their screen going complelely white every so often. Have had the maching into the Apple store in Memphis. They could not get it to fail. Help
TutorDaddy, if this Mac is still covered by the initial warranty or under AppleCare, take it in and have it looked at. As the old label used to say, there truly are "no user serviceable parts inside." Kernel panics very usually indicate failing hardware.
I have an older iBook G4 that started developing kernel panics and like you, despite reinstalling the OS from a freshly formatted volume, they kept continuing. I looked at the crash log and saw that in each instance of panic, the last bit of code to be accessed had something to do with AirPort. Knowing that the AirPort software was at then current levels, I surmised the problem to be a bad AirPort networking card which, on that particular model of the iBook, was a very small module attached directly to the logic board. Since the computer was out of AppleCare, I broke the machine down myself (I didn't realize that there could be so many barely visible screws in one machine) and removed the offending piece of hardware. My iBook lives but without WiFi, it now sits as a more or less desktop machine needing an ethernet connection to stay connected to a network.
I do not suggest you break into your iMac. First of all, I'm guessing one would need to be able to pull off the glass and have the necessary glue to reattach it, which is not really available to us consumers. If you're feeling adventurous enough to read the crash logs from each panic, you might be able to surmise the hardware component (or badly written application or library; it can happen) that's causing the panic. If it's a software issue, remove the offending software app and see if the panics return. If it's a hardware issue, it's best to let a competent service tech qualified on Apple hardware to handle it.
[edited to add:]
After browsing through related problems in the discussions, I saw this link to a third-party web site being handed out. Perhaps you'll find it useful: http://www.thexlab.com/faqs/kernelpanics.html
Message was edited by: Stephen Adams -
Macbook Pro late 2013 - problem with login screen resolution
Hi,
I've got problem with login screen resolution, after upgrade to Yosemite. I use the 4rd resolution (last one) on my Mac Pro (late 2013), and after restart login screen is always on optimum mode... But it's only about the login screen.
Do you know how can I fix it? I would like to have the same resolution on every screen.
thx in advanceI Reformatted the CF card on the new computer it works fine now on the new Mac Pro
Interesting point about the low power of the usb ports I had to deal with all devices ejecting them selves when the mac pro was idle or slept Drobo needed a Firmware update and another drives needed me to change the sleep setting or the Mac Pro to never and i also had to deploy a script to write to each device ever minute, this kind of sold the problem with external Hard drives. I wonder if the lowering power to a CF card can eject it in a manor which would make the computer think it is corrupt.
I have looked at buying a power usb Hub but seems only one or two of the ports are powered.
Seems to be a bit problem with the mac pro especially as everything has to be connected externally
Will assume the Firewire Connector does not work.
Maybe you are looking for
-
Blank CD's do not show up on desktop
I have a G5 Imac. When is insert a blank disc it does not show on desktop. Recorded disc do. It work the day before and now it will not let me copy files or burn.
-
Custom Transaction for maintence of custom table
hi friends, i have created a custom table. and for it i need to have a custom maintenence transactions.the custom transaction should consits of insert, copy a row and upload.... but i dont think we have an upload feature in SM30, now my d
-
CS_BOM_EXPLOSION
Hi, I want to know from which table can I get STPOX-STUFE used in function module CS_BOM_EXPLOSION. Actually i need to know material level in BOM. Thanks/Regards.
-
Hi, I am using APEX 4.0 ver .I have created SQL report with 1 column and its looks good but problem is, This columns has huge amount of data for example 1000 words and in the report it is displaying like **********************************************
-
Pull Merchandize distribution with 3rd party SO
Hello, i want to build process with collective PO and 3rd party order. I like classical 3rd party order, but in case of vendor is internal vendor = supplying site, i am facing restriction. 3rd party can be only used for vendor which is not connected