Problemi di startup con field point 1000

Gentile Signore,
Nella nostra azienda Electrolux Home Products stiamo usando i vostri moduli Field Point tipo FP 110, FP 120 e FP 1000.Il SW che stiamo usando è fornito dalla CANARY LABS e la versione del Field Point è la 3.0. Vi allego la risposta del tecnico della CANARY LABS che ha visionato gli errori e mi ha consigliato di contattarvi.
Saluti
Attachments:
errors.txt ‏2 KB

I only know of the standard stuff on FieldPoint from NI.  The Quickstart Guide is good for wiring, and there is HELP>FieldPOINT in LabVIEW itself (you need to make sure the FieldPOINT software option is installed on your computer as it isn't in the default installation of LabVIEW).
After connecting you FP-1000 to an RS-232 COM Port, the next step is to open a new LabVIEW Project and Add New "Targets and Devices...":
From there you can get to the configuration screen:
-- James
 BTW, after the initial learning hurdle, FieldPOINT is very easy to use.

Similar Messages

  • Hello, I have created a distribution kit for my program.The problem is that the when the program is installed onto another computer, it fails to communicate with field point (Using FP-AO-200 and FP-AO-1000). Help is greatly appreciated, Thanks faen9901

    Hi Everyone,
    I have a program that sends information(analog output) to lab windows cvi in the form of a text file or user input.
    The program runs on the computers that I have the field point explorer and lab windows cvi installed on. In order to run the program without always installing labwindows/cvi and field point; I wanted to create an executable file that could be load on another computer.
    I used the create distribution kit part of labwindows/cvi to do this.After creating the distribution kit, I then installed it
    to another computer.
    My user interface appears on the screen, when the user clicks on the exe. file, but no data is sent to the field point module. I know that the data is being read from the user and textfile because in it appears in the uir.
    The following are some details about the problem:
    1. On another computer without labwindows/cvi and field point explorer not installed - no data is sent to field point module
    I know this because a current is being read on the current meter connected to field point module.
    My questions are the following:
    1. What are the possible reasons for the data not being sent to the field point module?
    2. Do I still need to create an iak. (Installing Field point Explorer) file stored on any new computer that I install my created distribution kit file too?
    Thankyou very much for any help that you can provide. I greatly appreciate it.
    Faen9901

    Re: Hello, I have created a distribution kit for my program.The problem is that the when the program is installed onto another computer, it fails to communicate with field point (Using FP-AO-200 and FP-AO-1000). Help is greatly appreciated, Thanks faen9901Faen9901,
    1) If you do not install FieldPoint Explorer, the FieldPoint Server is not installed so there is nothing on the target computer that knows how to talk to the FieldPoint system.
    2) Yes, you need an IAK file on the target computer. Assuming the settings (i.e. com port#) are identical you can simply include the iak file as part of the distribution.
    3) You also need to include as part of your installer the file "fplwmgr.dll". If this file is not installed, your program will not be able to access the FieldPoint Server. Alternatively, this file is installed automatically if FieldPoint Explorer detects LabWindows/CVI or Measurement Studio Development versions on the target computer or if you choose to do a custom FieldPoint Explorer installation and
    choose to provide LabWindows/CVI support.
    Regards,
    Aaron

  • Field Point FP-1000 communication issue - Device found but offline in MAX

    Hello,
    I am trying to control several field point PLCs in a level tank. They are communicating through a FP-1000 module. I am able to add the devices through a configuration file in MAX. But there is an error saying " The device is offline. Make sure the device is connected and its power is on. " All of the field point PLCs have green light on for both " Power" and "Ready". I am not sure what the issue is here. I am using Labview 2014 and Field Point , VISA drivers are installed. Please see attached pictures for details.
    Many Thanks
    FLiu
    Attachments:
    IMG_1359.JPG ‏4812 KB
    IMG_1360.jpg ‏2220 KB
    IMG_1361.jpg ‏2251 KB

    Thanks for your reply. I installed the most updated version for both ones. It turns out the configuration file for FP-1000 bank points to the wrong COM port for the Serial communication. I am able to communicate with the system now. I do have another problem through. I only have excutable labview files and a configuration file for the control system that I am working with. The original VI project file were lost. After importing the right configuration file in MAX, I installed the excutables and tried to run it. There is no response at all.The labview only last a few seconds and stopped. Any thoughts are greatly appreciated.
    Thanks
    Fliu

  • I have problem in transfeering data using field point via tcp

    I am reading the values from the filed point, which is connected, to the RT controller and transferring the values to the client PC via TCP at a specified acquisition rate.
     Case1 when the acquisition rate is 0.1 minutes I get the values from the controller correctly i.e. 5v, 5v, and the chart shows no change. The timed out of the TCP read is default value i.e. is 250ms
     But when I change the acquisition rate to .5 minutes I get the values as 5v, 0v, 5v, and 0v. The time out of the TCP read is same as first case. The inputs to the field point are at the constant 5v.
    Please tell how to solve the problem so as to see the plot in the chart continuously as inputs for the field points the read
    ing are at constant rate of input 5v.

    Suresh,
    Since this question deals with using the LabVIEW TCP/IP functions, you are better off posting it to the LabVIEW discussion forum.
    Regards,
    Aaron

  • I have a FP-1600 and a FP-AO-200 module, 0-20 ma. When I use Field Point Explorer 3.0.1, I can not command any of the channel output current. The current remains in the lowest value 0.0035 A. What is the problem ?

    I have a FP-1600 and a FP-AO-200 module, 0-20 ma. When I use Field Point Explorer 3.0.1, I can not command any of the channel output current. The current remains in the lowest value 0.0035 A. What is the problem ? The communications with the module are OK, because it shows when the current are open or closed.

    Jorg,
    I noticed that you claimed to be using the module in 0-20mA mode, yet the reading you are seeing is 3.5mA. This is the minimum value (with overranging) when the module is set to 4-20mA mode. My guess is that your module is defaulting back to 4-20mA mode, but your IAK file still thinks the module is in 0-20mA mode. You can verify this by using the find devices button in FieldPoint Explorer and then trying to write to the channel.
    To fix this problem, you should use the snapshot feature to change the default power-up mode for that channel.
    Regards,
    Michael Shasteen
    Applications Engineering
    National Instruments
    www.ni.com/ask
    1-866-ASK-MY-NI

  • Comment effacer un startup.exe dans un field point

    Je désire effacer le programme startup.exe d'un field point, je posséde labview 6.1 et field point explorer 3.0.2. Il est possible e le faire en démontant le FP , enlever la carte mémoire flash et la formater. Ensuite il faut tout réinstaller ce qui est laborieux.

    Oui j'ai essayé la simplicité avant le formatage. Je sais qu'il existe un Vi sous labview 7 qui gére ce cas, je me renseigne pour avoir le même en 6.1

  • Problem in startup of Shadow Instance (START_SHDI_FIRST)

    Hi Experts
    I am having problem in 4.6B - ERP6.0 Upgrade. I have problem in startup of Shadow Instance. Here is log description.
    DEVTRACE.LOG
    trc file: "dev_ms", trc level: 1, release: "700"
    Thr 01 Fri Feb 22 19:53:01 2008
    Thr 01 MsSSetTrcLog: trc logging active, max size = 20971520 bytes
    systemid 370 (Solaris on SPARCV9 CPU)
    relno 7000
    patchlevel 0
    patchno 133
    intno 20050900
    make: multithreaded, ASCII, 64 bit, optimized
    pid 7614
    Thr 01 ***LOG Q01=> MsSInit, MSStart (Msg Server 1 7614) http://msxxserv_mt. 1824
    Thr 01 SigISetDefaultAction : default handling for signal 18
    Thr 01 load acl file = /usr/sap/put/<SID>/SYS/global/ms_acl_info
    Thr 01 MsGetOwnIpAddr: my host addresses are :
    Thr 01 1 : http://192.168.21.21 <hostname> (HOSTNAME)
    Thr 01 2 : http://127.0.0.1 localhost (LOCALHOST)
    Thr 01 MsHttpInit: full qualified hostname = <hostname>
    Thr 01 HTTP logging is switch off
    Thr 01 ms/icf_info_server : deleted
    Thr 01 *** I listen to port sapmsSHD<SID> (3602) ***
    Thr 01 CUSTOMER KEY: >L0506167855
    trc file: "dev_rd", trc level: 1, release: "700"
    Fri Feb 22 15:25:15 2008
    ***LOG S00=> GwInitReader, gateway started ( 1059) http://gwxxrd.c 1691
    systemid 370 (Solaris on SPARCV9 CPU)
    relno 7000
    patchlevel 0
    patchno 133
    intno 20050900
    make: single threaded, ASCII, 64 bit, optimized
    pid 1059
    gateway runs with dp version 232(ext=109) (@(#) DPLIB-INT-VERSION-232)
    gateway (version=700.2007.10.01)
    gw/local_addr : 0.0.0.0
    CCMS: AlInitGlobals : alert/use_sema_lock = TRUE.
    CCMS: Initalizing shared memory of size 40000000 for monitoring segment.
    Bind service sapgw02 (socket) to port 3302
    GwPrintMyHostAddr: my host addresses are :
    1 : http://192.168.21.21 <hostname> (HOSTNAME)
    2 : http://127.0.0.1 localhost (LOCALHOST)
    Full qualified hostname =
    DpSysAdmExtCreate: ABAP is active
    DpSysAdmExtCreate: VMC (JAVA VM in WP) is not active
    Fri Feb 22 15:25:20 2008
    DpShMCreate: sizeof(wp_adm) 70080 (960)
    DpShMCreate: sizeof(tm_adm) 51017496 (25496)
    DpShMCreate: sizeof(wp_ca_adm) 184800 (88)
    DpShMCreate: sizeof(appc_ca_adm) 8800 (88)
    DpCommTableSize: max/headSize/ftSize/tableSize=2000/8/2192040/2192048
    DpShMCreate: sizeof(comm_adm) 2192048 (1088)
    DpSlockTableSize: max/headSize/ftSize/fiSize/tableSize=0/0/0/0/0
    DpShMCreate: sizeof(slock_adm) 0 (104)
    DpFileTableSize: max/headSize/ftSize/tableSize=0/0/0/0
    DpShMCreate: sizeof(file_adm) 0 (72)
    DpShMCreate: sizeof(vmc_adm) 0 (1840)
    DpShMCreate: sizeof(wall_adm) (224040/346312/80/104)
    DpShMCreate: sizeof(gw_adm) 48
    DpShMCreate: SHM_DP_ADM_KEY (addr: ffffffff5bc00000, size: 54051296)
    DpShMCreate: allocated sys_adm at ffffffff5bc00000
    DpShMCreate: allocated wp_adm at ffffffff5bc01cc0
    DpShMCreate: allocated tm_adm_list at ffffffff5bc12e80
    DpShMCreate: allocated tm_adm at ffffffff5bc12ee0
    DpShMCreate: allocated appc_ca_adm at ffffffff5ece77d8
    DpShMCreate: allocated comm_adm at ffffffff5ece9a38
    DpShMCreate: system runs without slock table
    DpShMCreate: system runs without file table
    DpShMCreate: allocated vmc_adm_list at ffffffff5ef00ce8
    DpShMCreate: allocated gw_adm at ffffffff5ef00d68
    DpShMCreate: system runs without vmc_adm
    DpShMCreate: allocated ca_info at ffffffff5ef00d98
    MtxInit: -2 0 0
    Fri Feb 22 15:25:26 2008
    GwDpInit: attached to gw_adm at ffffffff5ef00d68
    Fri Feb 22 15:25:44 2008
    caught SIGINT (2)
    ***LOG S30=> GwStopGateway, gateway stopped () http://gwxxrd.c 14586
    STARTSFI.LOG
    1 ETQ201XEntering upgrade-phase "START_SHDI_FIRST" ("20080222195300")
    2 ETQ367 Connect variables are set for standard instance access
    4 ETQ399 System-nr = '01', GwService = 'sapgw01'
    4 ETQ399 Environment variables:
    4 ETQ399 dbs_ora_schema=SAPR3
    4 ETQ399 auth_shadow_upgrade=0
    4 ETQ399 Set environment for shadow connect:
    4 ETQ399 ENV: dbs_ora_schema=SAPR3
    4 ETQ399 ENV: auth_shadow_upgrade=1
    4 ETQ399 Set RFC variables for shadow connect:
    4 ETQ399 System-nr = '02', GwService = 'sapgw02'
    4 ETQ399 Set tool parameters for shadow connect:
    4 ETQ380 computing toolpath for request "TP_SHADOW_CONNECT"
    4 ETQ381 request "TP_SHADOW_CONNECT" means "tp needs to connect to shadow system"
    4 ETQ382 translates to group "R3UP_TOOL_GROUP_NEW"
    4 ETQ383 translates to path "exe"
    4 ETQ383 translates to path "exe"
    4 ETQ399 default TPPARAM: SHADOW.TPP
    4 ETQ380 computing toolpath for request "TP_ALWAYS_NEW"
    4 ETQ381 request "TP_ALWAYS_NEW" means "always tp from DIR_PUT/exe, for phase KX_SW<SID>H"
    4 ETQ382 translates to group "R3UP_TOOL_GROUP_NEW"
    4 ETQ383 translates to path "exe"
    4 ETQ383 translates to path "exe"
    2 ETQ399 Starting shadow instance
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2 ETQ353 Starting system
    4 ETQ399 ext. env.: DIR_LIBRARY=/usr/sap/put/<SID>/homeshd/<SID>
    4 ETQ399 ext. env.: LD_LIBRARY_PATH=/usr/sap/put/<SID>/homeshd/<SID>:/usr/j2se/jre/lib/sparc/c
    lient:/usr/j2se/jre/lib/sparc:/usr/j2se/jre/../lib/sparc:/oracle/<SID>/102_64/lib:/usr/sap/I
    TC/SYS/exe/run:/oracle/client/10x_64/instantclient
    4 ETQ399 2008/02/22 19:53:00: put_execute: (startsap) forkpid:7500
    2 ETQ370 starting test RFC
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2WETQ372 test RFC failed, rc="-2"
    2 ETQ370 starting test RFC
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2WETQ372 test RFC failed, rc="-2"
    2 ETQ370 starting test RFC
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2WETQ372 test RFC failed, rc="-2"
    2 ETQ370 starting test RFC
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2WETQ372 test RFC failed, rc="-2"
    2 ETQ370 starting test RFC
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2WETQ372 test RFC failed, rc="-2"
    2 ETQ370 starting test RFC
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2WETQ372 test RFC failed, rc="-2"
    2 ETQ370 starting test RFC
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2 ETQ231 RFC Login failed
    4 ETQ359 RFC Login to: System="<SID>", Nr="02", GwHost="<hostname>", GwService="sapgw02"
    2 ETQ231 RFC Login failed
    2WETQ372 test RFC failed, rc="-2"
    2EETQ399 Starting shadow instance failed
    2EETQ399 Test RFC failed finally
    2EETQ399 Dialogue: ERROR
    2EETQ399 Starting system failed, rc=0
    Please let me know if you have any ideas.
    Thanks & best Regards
    L Raghunahth

    Hi ,
    I am forwarding the dev_w0 log.
    dev_w0 ==> log is as follows
    M Fri Feb 22 15:25:26 2008
    M  ab_init o.k.
    M  ThrInitGlobals o.k.
    M  ThrCreateShObjects           allocated 150834 bytes at ffffffff52200000
    M  SosRegisterMemAddr: add mem addr ffffffff52200000 / >thr_serv_info<
    M  SosRegisterMemAddr: add mem addr ffffffff52200010 / >thr_wpadm<
    M  ThrCreateShObjects o.k.
    M  SosRegisterMemAddr: add mem addr 1050aace0 / >ztta<
    M  SosRegisterMemAddr: alloc/realloc table
    M  SosRegisterMemAddr: add mem addr 105328a60 / >spa<
    M  ThrRegisterMemAddrs o.k.
    M  ThJRegNatives3: java not active
    M  ThrInitRunTime: ThrtRegJavaNatives failed (-1)
    M  ThJRegNatives3: java not active
    M  ThrInitRunTime: ThrtRegWpWriterJavaNatives failed (-1)
    M  ThJRegNatives3: java not active
    M  ThrInitRunTime: ThrtHttpRegWpJavaNatives failed (-1)
    M  ThJRegNatives3: java not active
    M  ThrInitRunTime: ThrtHttpRegUsrJavaNatives failed (-1)
    M  ThJRegNatives3: java not active
    M  ThrInitRunTime: ThrtHttpRegMemJavaNatives failed (-1)
    M  ThJRegNatives3: java not active
    M  ThrInitRunTime: ThrtHttpRegSysJavaNatives failed (-1)
    M  ThrInitRunTime o.k.
    M  ab_startup o.k.
    N  SsfSapSecin: putenv(SECUDIR=/usr/sap/put/<SID>/DVEBMGS02/sec): ok
    N
    N  =================================================
    N  === SSF INITIALIZATION:
    N  ===...SSF Security Toolkit name SAPSECULIB .
    N  ===...SSF trace level is 0 .
    N  ===...SSF library is /usr/sap/put/exe/libsapsecu.so .
    N  ===...SSF hash algorithm is SHA1 .
    N  ===...SSF symmetric encryption algorithm is DES-CBC .
    M  load shared library (/usr/sap/put/exe/libsapsecu.so), hdl 1
    N  ===...sucessfully completed.
    N  =================================================
    M
    M  Returncode of AlMCCreateAttach (): 50
    M  Returncode of AlMOCreateAttach (): 50
    M  Returncode of AlSmesCreateAttach (): 50
    M  *** Start of API function likey_init ***
    M  likey_init: sid = "<SID>"
    M  likeymem_calloc (2, 21) for type "List of the SW products" returns 1050a55e0.
    M  likey_init: products [0] = "R3_ORA              "
    M  likey_init: products [1] = "R3_BASIS            "
    M  likey_init: basis_release = "700"
    M  likey_init: temporary license keys allowed.
    M  likey_init: running within the SAP WebAS ABAP.
    M  Generated absolute filename of the verify PSE: "/usr/sap/put/<SID>/DVEBMGS02/sec/LASVerif
    y.pse"
    M  PSE name "/usr/sap/put/<SID>/DVEBMGS02/sec/LASVerify.pse" memorized.
    M  The contents of the PSE file "/usr/sap/put/<SID>/DVEBMGS02/sec/LASVerify.pse" is the 2038
    version.
    M  SAPSECULIB initialized by calling SsfLibGetToolkit ().
    M  likeyper_init: insert_record memorized.
    M  likeyper_init: update_record memorized.
    M  likeyper_init: delete_record memorized.
    M  likeyper_init: get_record memorized.
    M  likeyper_init: get_all_records memorized.
    M  likeyper_init: cleanup memorized.
    M  likeyche_get_existing_buffer: buffer found in EG memory.
    M  likeyche_get_existing_buffer: magic number okay, reserved entries = 5, used entries = 0
    M  *** End of API function likey_init ***
    M  SAPlicense: LIKEY initialisation done
    M  ThBtcClnZombies o.k.
    M  Enq-Reset-Registration o.k.
    M  SosRegisterHook: add hook >rsts_storage_free(101a2ee78)< for event AFTER_STORAGE_FREE
    M  SosRegisterHook: add hook >rsts_before_commit(101a2efb0)< for event BEFORE_COMMIT
    M  SosRegisterHook: add hook >rsts_after_commit(101a2f098)< for event AFTER_COMMIT
    M  SosRegisterHook: add hook >rsts_after_rollback(101a2f168)< for event AFTER_ROLLBACK
    M  SosRegisterHook: add hook >rsts_after_rollback(101a2f168)< for event AFTER_ROLLBACK_WOR
    K
    M  SosRegisterHook: add hook >rsts_after_rollin(101a2acd0)< for event AFTER_ROLL_IN
    M  SosRegisterHook: add hook >rsts_before_rollout(101a2acec)< for event BEFORE_ROLL_OUT
    M  DpISetTrcLog: trc logging active, max size = 20971520 bytes
    M  DpISetTrcLog: sw<SID>h off trace logging global is off
    M  DpISetTrcLog: trc logging active, max size = 20971520 bytes
    M  ThSetTrcLogParam2 o.k.
    M  register db commit/rollback hook o.k.
    N  MskiInitLogonTicketCacheHandle: Logon Ticket cache pointer retrieved from shared memory
    N  MskiInitLogonTicketCacheHandle: Workprocess runs with Logon Ticket cache.
    M  MskiInitLogonTicketCacheHandle o.k.
    M  ThrtRegisterJCoNatives o.k.
    M  JrfcVmcRegisterNativesDriver o.k.
    M  ThJRegNatives3: java not active
    M  EnqVmcRegisterNatives failed
    M  ThJRegNatives3: java not active
    M  JMonVmcRegisterNatives failed
    M  ThJRegNatives3: java not active
    M  JTSAuthorityRegisterNatives failed
    W  =================================================
    W  === ipl_Init() called
    W    ITSP ICMAN is not active: Disable Kernel Web GUI functionality
    W  === ipl_Init() returns 2, ITSPE_DISABLED: Service is disabled (sapparam)
    W  =================================================
    M  ipl_Init returns 2 ITSPE_DISABLED: Service is disabled (sapparam)
    M  SosRegisterHook: add hook >DbgBeforeSessionEnd(100495c64)< for event BEFORE_SESSION_END
    M  SosRegisterHook: add hook >DbgBeforeTaskSw<SID>h(10049575c)< for event BEFORE_TASK_SW<SID>H
    M  ThDbgInit returns 0
    M  ThJRegNatives3: java not active
    M  ThDSysEnv: delete environment
    M  REL WP ca_blk 56
    M  ThDtWpBlk: detach WP ca_blk 56
    M  REL APPC ca_blk 2
    M  ThDtAppcBlk: detach APPC ca_blk 2
    M  ThIEmFree: delete hyper context (hyperHdl=fffffffdd99f1e60)
    M  ThIEmFree: call EmContextDelete (em_hdl=0)
    M  set act fields to T-1/M255
    M  ThSetProcessPriority o.k.
    M  SosRegisterMemAddr: add mem addr ffffffff57412e80 / >tm_adm_list<
    M  SosRegisterMemAddr: add mem addr ffffffff57412ee0 / >tm_adm<
    M  SosRegisterMemAddr: add mem addr ffffffff57401cc0 / >wp_adm<
    M  SosRegisterMemAddr: add mem addr ffffffff53000000 / >wp_ca<
    M  SosRegisterMemAddr: add mem addr ffffffff5a4ba5f8 / >wp_ca_adm<
    M  SosRegisterMemAddr: add mem addr ffffffff5a4e9a38 / >comm_adm<
    M  SosRegisterMemAddr: add mem addr ffffffff5702edc0 / >appc_ca<
    M  SosRegisterMemAddr: add mem addr ffffffff5a4e77d8 / >appc_ca_adm<
    M  SosRegisterMemAddr: add mem addr 0 / >vmc_adm<
    M  SosRegisterMemAddr: alloc/realloc table
    M  SosRegisterMemAddr: add mem addr ffffffff57400000 / >sys_adm<
    M  ThCheckComOrRb (event=1, full_commit=0)
    M  ThCallHooks: call hook >ASTAT-collect commit handling< for event BEFORE_COMMIT
    M  ThCallHooks: call hook >rsts_before_commit< for event BEFORE_COMMIT
    M  SosCheckAbapEnv: invalid tid/mode T-1/M255
    M  ThCheckComOrRb (event=3, full_commit=0)
    M  ThCallHooks: call hook >dyKeyTableReset< for event AFTER_COMMIT
    M  ThCallHooks: call hook >ThNoClearPrevErr< for event AFTER_COMMIT
    M  ThNoClearPrevErr: clear prev no err
    M  ThCallHooks: call hook >rsts_after_commit< for event AFTER_COMMIT
    M  SosCheckAbapEnv: invalid tid/mode T-1/M255
    M  ThCallHooks: call hook >SpoolHandleHook< for event AFTER_COMMIT
    M  SosCheckAbapEnv: invalid tid/mode T-1/M255
    M  db_commit98 (keep resources) o.k.
    M  SigSave o.k.
    M  rdisp/rfc_use_quotas : 1
    M  rdisp/rfc_max_queue : 5
    M  rdisp/rfc_max_login : 90
    M  rdisp/rfc_max_own_login : 25
    M  rdisp/rfc_min_wait_dia_wp : 1
    M  rdisp/rfc_max_own_used_wp : 75
    M  rdisp/rfc_max_comm_entries : 90
    M  rdisp/rfc_max_wait_time : 15
    E Fri Feb 22 15:25:29 2008
    E  Replication is disabled
    E  EnqCcInitialize: local lock table initialization o.k.
    E  EnqId_SuppressIpc: local EnqId initialization o.k.
    E  EnqCcInitialize: local enqueue client init o.k.
    M  init lock table o.k.
    M  ThrSetMemHdl o.k.
    M  ThInit o.k.
    M  SigIRegisterExitRoutine: exithandler installed (ThSigHandler)
    M  TskhLoop: tell dispatcher: I'am ready for processing
    M  LOCK WP ca_blk 56
    M  LOCK APPC ca_blk 2
    M  ThIEndBg: end background processing of T-1 (type=0x41, logoff=1, freeResources=0)
    M  ThISend: (tm/user/type/info = -1/           ?/0x41/0x0, mode_deleted=1)
    M    TASK_SW<SID>H
    M    DISP
    M  abap strategy ROLL / O.K.
    M  ThRqOutCheck: o.k.
    M  ThNewWpStat (type=0x41, task_sw<SID>h=1, inline_hold=0, hand_shake=0, debug=0, ..)
    M  ThISend: new wp stat: 0x2
    M  rdisp/wp_auto_restart = 0 sec
    M  rdisp/wp_abap_restart = 0
    M  ThSetThToolParam : restartable_wp[0] = FALSE
    M  ThSetThToolParam : restartable_wp[1] = TRUE
    M  ThSetThToolParam : restartable_wp[2] = TRUE
    M  ThSetThToolParam : restartable_wp[3] = FALSE
    M  ThSetThToolParam : restartable_wp[4] = TRUE
    M  ThSetThToolParam : restartable_wp[5] = TRUE
    M  ThSetThToolParam : restartable_wp[6] = TRUE
    M  ThDtWpBlk: detach WP ca_blk 56
    M  ThISend: clear stat record
    M  PfClearAllRec: clear statistic area
    M  ThISend: stat_state = TH_STAT_CLEAR
    M  ThISend: th_wp_waits_for_rq = TH_WP_WAITS_FOR_RQ
    M  make DISP owner of wp_ca_blk 56
    M  DpRqPutIntoQueue: put request into queue (reqtype 0, prio LOW, rq_id 18)
    M  -OUT- sender_id WORK_PROCESS      tid  -1    wp_ca_blk   56      wp_id 0
    M  -OUT- action    SEND_TO_DP        uid  -1    appc_ca_blk -1      type  NOWP
    M  -OUT- new_stat  WP_WAIT           mode 0     len         8       rq_id 18
    M  wake_evt_udp_now 1, no dgram needed
    M  REL APPC ca_blk 2
    M  ThDtAppcBlk: detach APPC ca_blk 2
    M  ThCallHooks: call hook >SAP-Trace buffer write< for event BEFORE_TASK_SW<SID>H
    M  TrThHookFunc: called for task sw<SID>h
    M  ThCallHooks: call hook >ImcResetPtr< for event BEFORE_TASK_SW<SID>H
    M  ThCallHooks: call hook >HttpResetPtr< for event BEFORE_TASK_SW<SID>H
    M  ThCallHooks: call hook >DbgBeforeTaskSw<SID>h< for event BEFORE_TASK_SW<SID>H
    M
    M  ********* W0 LOOP (DIA) *********
    M  TskhLoop: save spa pointer 105328a60 and install dummy spa
    M  ThRqWaitFor: wait for next request (new time slice)
    M  event-handling: W0, key 50240, flag 50240
    M  ThAlarm: no previous alarm
    M  ThRqWaitFor: wait for request
    M Fri Feb 22 15:25:42 2008
    M  in_ThErrHandle: 1
    M  ThIErrHandle: new stat of W0 is WP_SHUTDOWN
    M  ThIErrHandle: I'm during shutdown
    M  PfStatDisconnect: disconnect statistics
    M  Entering ThSetStatError
    M  ThCallDbBreak: use db_sqlbreak
    M  ThIErrHandle: don't try rollback again
    M  ThShutDownServer: shutdown server
    M  PfStatIndInit: Initializing Index-Record
    M  PfWriteIntoFile: copied shared buf (0 bytes) to local buf
    M  ThIErrHandle: do not call ThrCoreInfo (no_core_info=0, in_dynp_env=0)
    M  Entering ThReadDetachMode
    M  call ThrShutDown (1)...
    M  ThDBDisconnect: disconnect from data base
    B  Disconnecting from ALL connections:
    B  Wp  Hdl ConName          ConId     ConState     TX  PRM RCT TIM MAX OPT Date     Time
    DBHost
    B  000 000 R/3              000000000 INACTIVE     NO  YES NO  000 255 255 20080222 152515
    <hostname>
    C  Disconnecting from connection 0 ...
    C  Closing user session (con_hdl=0,svchp=105b54538,usrhp=105b51478)
    C  Detaching from DB Server (con_hdl=0,svchp=105b54538,srvhp=105b56868)
    C  Now I'm disconnected from ORACLE
    B  Disconnected from connection 0
    B  statistics db_con_commit (com_total=2, com_tx=0)
    B  statistics db_con_rollback (roll_total=0, roll_tx=0)
    M  ThDBDisconnect: disconnect o.k.
    M  ***LOG Q02=> wp_halt, WPStop (Workproc 0 1060) [dpuxtool.c   260]
    M  Good Bye .....
    Best Regards,
    L Raghunahth

  • Configurar un nuevo field point

    Saludos, he adquirido un nuevo cFP-2020, este obviamente viene sin ninguna configuracion ni software. Mi problema es, que aunque el cFP2020 debe de tener una IP de 00.00.00.00 en el MAX no se aprecia.
    Alguien puede indicarme por favor, como configurar este nuevo field point para verlo en el MAX?
    Gracias

    Que tal Anghell,
    Si ya instalaste el software de FieldPoint asgúrate de lo siguiente:
    -Si estás conectando el cable directamente a la computadora asegúrate que se trate de un cable cruzado y verifica que esté funcionando correctamente haciendo "ping" a otra computadora con ese cable. Si te estás conectando directamente a la red utiliza un cable "straight".
    -Verifica que el Firewall esté desactivado en el host.
    -Posteriormente verifica el status tanto de los leds del controlador y de acuerdo al patrón de parpadeo en los mismos (si es que lo hay). Tras haber verificado el patrón identifica a que status corresponde de acuerdo al apéndice A del manual. 
    http://www.ni.com/pdf/manuals/370708b.pdf
    -Si el status es 1 (el controlador está desconfigurado o con el switch de RESET IP en la posición "ON") probablemente esté desconfigurado. Si este es el caso cambia la posición del switch RESET IP a "ON", presiona el botón RESET, posteriormente apaga y enciende el controlador y regresa el witch IP a "OFF".
    -Si este no es el caso probablemente, tienes la version 4.2 de MAX probablemente el problema radique en la version que tienes de MAX, para lo cual necesitas descargar la version más reciente de los drivers de FieldPoint que te instale la version más reciente de MAX, o en su defecto utilizar el parche citado en el siguiente documento:
    http://digital.ni.com/public.nsf/allkb/D3076C71B32910D9862572A30064528A?OpenDocument
    Espero que esta información te sea de utilidad para resolver el problema. Si esto no resuelve el problema no dudes en contactarte nuevamente con nosotros.
    Saludos

  • Can FTP-access to field point log file interrupt the running program?

    Can FTP-access to field point log file interrupt the running program?
    We have a problem where our factory process control program on a Field Pointer suddenly stops the process. We are running the development system on a PC, wich deploys the program on the Field point, with user interface on the PC. Quite often the process stops for no apparent reason. I'm not sure right now if the control program on the Field Point is still running or if it stops. We use FTP from a distant PC (over VPN) directly to the Field Point to check if the process is running, by looking for date and size of log files produced during running process. I've never opened och copied any log file during process run, because this I'm sure this would cause problems for new log entries to be written. But can the mere looking at the log folder via XP-pros ftp-functionality cause the Field Point to have problems writing data to a log file?
    I'm not sure how windows XP pro handles "my network places" when it comes to FTP, it look that it keeps some kind of local copy of the folders, or at least the files opened.
    Next version of the program will have only basic functionality on the Field Point, leaving logging etc. to another program on the PC, but right now we are stuck with this system.
    Ola A

    It turned out that the problem lies in the harware of the production machine, it was not a labiew-program problem at all!
    Ola

  • Problems displaying rtf memo fields

    Post Author: Davidm
    CA Forum: General
    We use Crystal Reports X to run reports on an Access database with a significant number of rtf memo fields. We use Total Access Memo to allow extended use of rtf within Access as our users require the additional formatting capabilities that this offers.
    However, there are considerable problems displaying items like bullet points, tables and hyperlinks in the Crystal Viewer with tables in particular coming out in a real mess with all entries in the table being displayed in a list with a small square marking each cell at the end of each line.
    Curiously, if you preview the report in the full version of Crystal X, it appears a bit better with the hyperlinks still underlined (bullet points still vanish) and rows in rtf tables are at least presented as a row even if the columns are not ordered and mixed (with no bounding cells visible).
    Firstly, is this disparity of end result between full Crystal X Print Preview and the Crystal X Viewer fixable?
    Secondly, is the limited handling of rtf tags likely to be solved in the next release of Crystal?

    Hi Mathias,
    If I caught you correctly, you want to display data in Adobe forms in form of tabel, right?
    So, follow the steps:
    1. Insert one sub form on your adobe form.
    2. Set its type as "flow content" in object->subform property.
    3. Set flow direction as "Table".
    4. Insert another subform inside this subform.
    5. set its type as "flow content" and flow direction as "Table row".
    6. Now, choose binding tab, and there check "repeat subform for each Data item check box" and specify min. count for your rows.
    7. Now, insert your column fields inside this sub form once.
    8. Format its look and feel as you want.
    When you run this application, it will show you multiple data as table on Adobe form.
    Regards,
    Bhavik

  • Problem to modify the field "location" in an AP on WCS

    Hello everybody,
    I have a problem to modify the field "location" in an access point on WCS.
    In fact, when i try to modify this field and then apply the modification, i have this error message :
    "Error(s): You must correct the following error(s) before proceeding:
    Error:Global Username and Password are not configured on the associated controller.  Please configure username and password on the associated controller before disabling 'Override Global Username Password'."
    I made the modification on Chrome and Firefox but I always have the error message.
    Nevertheless, i don't have this error message with other access points and other access points are configured without the option "Override Global Username Password".
    I'm obliged to make the modification directly in the controller and not in WCS.
    The problem is that i want to make the modification directly in WCS.
    Could you help me please ?
    Thank you in advance.

    When i make the modification directly in WCS, i have no problem, it syncs good.
    The version of WCS is 7.0.230.0.
    The version of the controller is 7.0.240.0 and the field recovery image version is 7.0.112.21.
    Version
    7.0.230.0
    Version
    7.0.230.0
    Version
    7.0.230.0

  • OIM11 R2 - Problem with custom LOV field

    I created UDF LOV field pointing at lookup. I'm able to set value for this field by API. Now I want to show this field at user details form. Following http://docs.oracle.com/cd/E27559_01/admin.1112/e27149/customattr.htm#BABGDEIC I see my field in 'UserVO1'(Data Component - Manage Users) object, but when I select it and choose 'ADF Output Formatted w/Label' (or 'ADF Output Text') only lkv_encoded (key of lookup) is shown, not a lkv_decoded (value of lookup).
    Am I doing something wrong or it's not supported in current release?
    Did somebody successfully add UDF LOV to user details form?

    Hello,
    We are with the same problem, could you find the solution to your case?
    We can see the correct values (lkv_decoded) in the Create and Modify Page, but not in the Manage Users.
    Please can anyone help?

  • Problem in Startup 10g DB

    Dear all
    i m facing a little problem in startup 10g DB i m using 10g DB on Windows 2000 Professional operating system
    when i start data base from enterprize manager i log on SYS user then i select Startup then i feed some parameter like
    1) Host Credentials
    Specify the OS user name and password to login to target database machine
    i feed there operating system user name & passowrd
    then
    2)Specify the credentials for the target database.
    To use OS authentication, leave the user name and password fields blank.*
    i enter sys user and his password
    Database yasir
    Connect As SYSOPER
    when i pressed OK button then ii face that error
    Error Message
    RemoteOperationException: ERROR: Wrong password for user
    but my both password operatin system & sys password are correct
    any one have any idea what is problem & how can i slove my problem
    Thanks
    Rizwan

    From control panel go to
    1. Administrative tool---local security policy---local security settings
    2.From the local security settings windows: local policies---user rights assignment
    3.double click "log on as a batch job, add the administrative user you want to assign on the OEM.
    Hope this works for you.

  • Field point Fpquad510

    Hi,
    In the driver of field point i have a problem configuration range, channel
    configuration coerce the setting of analog input channel (speed) at the
    default value, but for my best read measure i setting this item of the minum
    resolution.
    I have quadrature encoder with 2500 ppt resolution, i have a problem also
    with position control, how is possible to set the count in radiant angle?
    If You know site or linking at this problem thank for send me.
    Thank' at all for the certainly answer
    Nic

    Thank's for answer,Buddy
    The first problem is the FP explorer in the channel configuration ,
    accepted the range indicated in analog channel of the encoder channel,but
    when i restart the computer it set the default value.
    The encoder is a 2500 point/tour quadrature tipe differential.
    I think the analog input of this channel is a speed read.
    the problem of position is by if the read channel position shown a position
    at 0-65536 and in the other side is 65536-0, where is a correct method for
    display the position for one tour and know the angle?
    thank
    "Buddy Curtis" ha scritto nel messaggio
    news:[email protected]..
    > For your first question about configuration, you will have to clarify
    > your exact problem (wha
    t resolution,accuracy,speed issues are you
    > experiencing).
    >
    > For second question about position measurement. There is no "built-in"
    > option to translate the current position to radiant angle in hardware.
    > You will have to read the current count and convert it to position in
    > software.

  • Installer promblem lv8 and field point

    I have the professional version of labVIEW 8.  I installed it and couldn't find the fieldpoint vi's. I moved them over from my old labVIEW 7.1. But, it seems that I am missing some menu files that one knowledge base refers to: http://digital.ni.com/public.nsf/websearch/7B21ADB6CD5ADCDF86256A3B0052D2A0?OpenDocument
    Copy the FieldPoint folder into your Program Files\National Instruments\LabVIEW 7x\vi.lib folder.
    Copy the fpConfiguration.mnu, fpOptomux.mnu, fpPublish.mnu, and fpRT.mnu files into your LabVIEW 7x\vi.lib\addons folder.
    Copy the ExpresFP.mnu file into your LabVIEW 7x\menus\default\Express folder.
    I don't have the fpPublish or the fpRT mnu files, or the ExpresFP.mnu files
    I have renamed all of my old versions of labVIEW (ie. oldlabview7.1).  I have uninstalled the fieldpoint 4.1 through the windows control panel and downloaded the field point 4.1 zip and reinstalled it.  There seems to be no support files for labVIEW 8.  After doing this, the above files are not anywhere on my computer.  Also, when I go to create an installer, under the additional installers there is no field point choice.
    I have tried numerous uninstalls and reinstalls of fieldpoint 4.1 and well as trying both cds of device drivers.  Another thing is that on the knowledge base about creating installers: http://zone.ni.com/devzone/conceptd.nsf/webmain/5ADBC06AC32E508A8625706E0062EBD1
    The example shows the box checked for fieldpoint "5", is there such a thing?
    When I get everything working, a question about the iak file.  I know that it needs to be put on the target computer in the same place the vi will look for it. If it is something like  C:/myapp.iak, is there a way that the installer could put it there so it wouldn't have to be done manually from the app/install cd?
    Thanks
    Jim

    I seemed to have fixed some of the problem with: http://digital.ni.com/public.nsf/allkb/B62BA881D8ED1FF48625709E00680BF0
    However, when creating an installer there still is no fieldpoint checkbox under additional installers
    Jim

Maybe you are looking for

  • ASA 5515 management interface

    I started to configure a new ASA 5515 to replace an 5510.  When I attempted to remove the "management-only" command from the Management0/0 interface I was greeted with the following error: "ERROR: It is not allowed to make changes to this option for

  • Film from Computer to i Pad

    I have converted a .mov clip (produced on Final Cut Express) to both Mpeg4 and H.264 file formats, loaded into i Tunes, and my i Pad 2 will still not accept it. It will accept low resolution and it will accept 4:3 aspect ratio, but not acceptable qua

  • My 5s font size grows way to big all by itself and I can't reduce it.

    My 5s font size grows way to big all by itself and I can't reduce it

  • Using Deployable Proxy in J2ee Server library

    Hallo experts, i want to use a deployable proxy in a j2eelibrary. In the j2eelibrary i have a plain java class, that consumes the deployable proxy. with a webdynpro i tested it and got a classaCastException in the java class (in j2eelibrary) where "c

  • Oracle by example new link

    Any one know what is the new link for http://www.oracle.com/technology/obe/fusion_middleware/im1014/ovd-oam/oam-ovd/install_oam/install_oam.htm address? This one takes you to the index page I am not able to search the OAM-OVD integration example. Tha