Problems using event structure to write new parameter values to VISA

Attachments:
FMA_event_2.vi ‏28 KB
FMA_event_2.vi ‏28 KB

It seems I'm also having trouble using forums..not sure what happened...updated and corrected thread: http://forums.ni.com/t5/LabVIEW/Problems-using-event-structure-to-write-new-parameter-values-to/td-p...

Similar Messages

  • Can I use Event structures in a subVI?

    Hi,
    I have a subVI (ProvaEv1.vi) that use an event structure inside. But when I use it in a VI (ProvaVI.vi) the event structure in the subVI doesn't catch the events.
    I tried to insert the event structure in a while loop but it doesn't work too.
    Could you help me?
    Thanks Ius
    Attachments:
    ProvaVI.vi ‏11 KB
    ProvaEv1.vi ‏15 KB

    "iusn" <[email protected]> wrote in message news:[email protected]...
    Thanks to all for your answers!
    Wiebe! I tried to do as you suggested but I am not able to link the Event Reference Number inside te SubVI with the Event Register Number of the Register for Event in Main VI. There is e class conflict. Another question: how the SubVI can know the structure of the Register event outside?My aim was to create a modular structure but it seems very difficult, wath do you think about these problems?
    The broken wire is related to your question. The event structure inside the sub vi knows about the events you register in the main, because the reference wire/control has a "strong" type. It contains information about the registered events. That is also why the wire is broken. You have to register all events, then create an indicator/control of the output. Use that control in the subvi. You have to do this every time the events change (you might use a type def if you use the control a lot).
    Usually, the events that you would want to put inside subvi's are those related to user interface objects. I've had this a lot. You make a nice interface, but it's not reuseable, because the events are mixed with all the other events. Only solotion is to manually add the needed event cases in your program, and copy the code.
    Even if you can put the events in a sub vi, I'd expect hanging vi's when more subvi's are registered for the same event. It's hard to tell without trying. So it's not a real solution either.
    Like Chrisger suggested, the event callback might help a little, but they are tricky, and actually ment for this (they are intended for activex callbacks).
    Perhaps you should look at XControls (if you use 8.2). It would be more work to replace your code to XControls, but once you're done, you have reusable code.. Haven't worked with them jet, but they are invented for this problem...
    Regards,
    Wiebe.
    I have already create my application using event structure just in Main VI but it seems very complicate to read and keep update, I would have wanted to give modularity to my application.
    Thanks Ius
    SubVIEventMain.vi:
    http://forums.ni.com/attachments/ni/170/203225/1/SubVIEventMain.vi
    SubVIEvent.vi:
    http://forums.ni.com/attachments/ni/170/203225/2/SubVIEvent.vi

  • Exit from the application using event structures

    Hi
    In my project i used event structure it working fine.
    Now i want to exit(close) the application when i press EXIT button on the front panel.
    Here i attached my project give an idea.
    Regards
    hari
    Solved!
    Go to Solution.
    Attachments:
    Sledge.zip ‏40 KB

    Hi SAM
    U saw my ok.i have one more problem when i run the program(main vi) all the remain sub vi's also opened.
    i want open sub vi when i press a button on front panel.
    i have made small changes to it.
    Regards
    hari 
    Attachments:
    Sledge.zip ‏41 KB

  • Firing events from a Menu using Event Structure - all in the same Event Window?

    I have an ap where I have three menus, and several selections from
    those three menus. I'm trying to keep everything within the Event
    Structure, but it seems that ALL of the events fired from the Menu must
    be contained within one "frame" of the Event Structure, that being the
    Menu Selection (user) Event. In other words, if I have 16 events that
    can be fired from the menu, do I have to put them ALL in this one event
    frame?
    I can't seem to use a T/F indicator within the Menu Selection (user)
    Event to access another Event. For example, within the Menu Selection
    (user) Event, I placed a boolean named X and can turn it on with a menu
    selection. Now, make a new Event Structure to look for X Value Change -
    doesn't work.
    Message Edited by Broken Arrow on 11-30-2005 10:24 AM
    Richard

    I use one event, Menu Selection (user). to trap all of my menu events.  Use Item Path and / or Item Tag to figure out what menu item was selected then branch code based on selection.  Wtih Booleans and menus you need to update the state of the boolean on the menu by setting it True or False.  It doesn't automatically toggle like you would expect.
    Matt
    Matthew Fitzsimons
    Certified LabVIEW Architect
    LabVIEW 6.1 ... 2013, LVOOP, GOOP, TestStand, DAQ, and Vison
    Attachments:
    menuSelect.JPG ‏45 KB

  • How to run the two events at the same time by using event structure

    In my project, I have to run two stepper motor which can run both forward and reverse direction by changing the control in front panel so I am using event structure. In front panel I gave two separate controls for both stepper motor such as forward,reverse and stop. I would like to do motor1 will rotate alone, motor2 will rotate alone and both motor will rotate at the same time when user click the control in front panel. My doubt is how to run a motor2 while motor1 is running at the same time please tell me the suggestion for this problem
    Attachments:
    motor.png ‏192 KB

    How do you control your motors?
    Most motion control systems do supply two modes:
    a) position based motion: The motion axis has a positioning system (most often some kind of encoder system) which enables the motion control to know where the axis is currently located. Passing the target location to the controller will result in the axis to move to that location. This is, for most applications, the recommended approach. It does require some sort of motion controller device.
    b) direction based motion: This essentially tells the periphery device for the motor to move at a certain speed into a certain direction. As it does not stop at a dedicated location, it induces great risks for many applications if there are no kill- and/or end-switches. Depending on the setup, this can be either done with motion controllers or pure by software control (e.g. "controlling" the voltage level for the motor).
    If you go for a), there is not much preventing parallelism as you request.
    Option b) depends on the setup. If you have a control loop in the software itself, you have to move to an architecture like the producer/consumer. Please note that this does not incorporate any security measures for the external devices.
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • How to use event structure of event data nodes event filter nodes in programming

    hi,
    I need manual of how to use 'event structure' events of 'event data nodes' and 'event data filters'...please help me....
    Regards
    Ravindranath

    I'm not really sure what you are looking for here.  Did you do a search in the LabVIEW help for Event Structure?
    The Event Data Node just returns information about the event, like control data, control reference, what caused the event, etc.
    The Event Data Filters are just used in Filter Events.  This allows you to discard an event or change the data that the event will recieve.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Stop graph using event structure

    How could I stop the wavform chart during running the loop using event structure?

    duplicate post
    Best regards,
    GerdW
    CLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 on WinXP+Win7+cRIO
    Kudos are welcome

  • How to control the tab control using event structure?

    Hi,
    I am using tab control and event structure in the program.
    When i run the application event is not happening for the active page.
    When user switches from active page to the other page then event is taking place for all pages
    So, how to get the event trigger for the active page when the application is started
    For more clarification i am attaching the code "Test Control Tab using Event Structure.vi"
    Attachments:
    Test Control Tab using Event Structure.vi ‏52 KB

    You have a basic misunderstanding of dataflow. Maybe you should start with some tutorials or study some of the examples that ship with LabVIEW.
    The event structure belongs inside the while loop, and not vice versa. RIght now, the event structure only runs exactly once and never again.
    If the stop is pressed first, the VI will stop. Game over.
    If the tab control is changed (from any state to any other state!), the inner loop will spin forever as fast as the CPU allows, either executing one or the other case. It just reads the tab terminal to decide which case to execute. Changing tab never triggers any events. The VI is trapped inside the event until stop is pressed to stop the VI.
    you were closer to a reasonable program in the other thread:
    http://forums.ni.com/ni/board/message?board.id=170&view=by_date_ascending&message.id=287905
    Have you tried execution highlighting? Maybe things would become more clear of you do.
    LabVIEW Champion . Do more with less code and in less time .

  • Problems with event source using event structure

    Hello!
    I'm using an event structure block. It works correctly when the event source is a control and the event is change value. But i want to use an indicator like event structure or a variable (like a matrix or a vector). I want that when the value changes, an event occurs, but it doen't work, I dont' know why?. What i have to do to work with indicators or variables in a event structure block?
    Thank you in advance
    Larson

    of course!
    regards timo
    Attachments:
    change_detection.vi ‏20 KB

  • Using Event Structures with Array of Clusters

    Using LabVIEW 8.5
    Hi all,
    I'm trying to convert an existing application to one that can be used
    through a touch screen. I updated the UI and added an event structure
    to listen for mouse ups on controls that require a HMI keyboard or
    numpad to show up. Although I've been programming for a while, I'm new
    to LabVIEW and am struggling with a problem:
    Is there any way to have an event case listen to an event within
    arrays? I've seen a few examples on the forums, but they all start with
    breaking up the arrays into individual variables. Using the variables,
    they build arrays. This seems pretty tedious, and I'm pretty sure I
    can't apply it to one of my arrays. Essentially, I just want to know
    which cluster in which array the user has clicked on, so I can open the
    HMI keyboard or numpad and send the text to that cluster. In my watered down app (Array of Clusters.vi), I've put 3 arrays of clusters and a few stand-alone controls to give you guys an idea of what I'm taking about.
    BTW, I'm using the HMI Keyboard and Numpad built by the Beta Community (http://decibel.ni.com/content/docs/DOC-1062) and modified it to add a "Clear" button to the keyboard and numpad. Please let me know if I implemented this in the best way.
    Thanks for the help,
    Kunal
    Message Edited by bhatiak on 08-04-2008 03:55 PM
    Attachments:
    Array of Clusters4.llb ‏274 KB

    My old tic tac toe example shows how to determine which square of a 2D array has been clicked.
    http://forums.ni.com/ni/board/message?board.id=170&view=by_date_ascending&message.id=247044#M247044
    You probably can adapt some of it for the arrays on the right. If the array can be scrolled, you also need to account for the "indexvals" offset.
    The Layers controls is easiest, because you only show one element. Just read the "index vals" property to get the array element and parse the coordinates to get the cluster element.
    btw: the small while loop on the right serves no purpose at all and acts just as a CPU burner. You can delete it without any change in functionality. Is there anything else to it?
    LabVIEW Champion . Do more with less code and in less time .

  • Labview 2013 cannot use event structure

    Event structure can be added into the back panel, however when i add event case or try to edit the default event case, the program is crask and cannot response to my mouse. 
    when i launch windows task manager, it present " running" properly.
    However this program run properly at my another computer with sample Win7 OS.
    Can anyone tell me what the problem is?

    Aaron1978 wrote:
    sir, this issue does not related to code, even i create new empty VI, the event structure cannot work properly, i cannot add new event or edit the default even!
    However, i installed the same eval version into my another computer, this event structure can work properly, both computers use same Win 7 OS.
    Okay in that case I would recommend a repair install of LabVIEW.  
    Unofficial Forum Rules and Guidelines - Hooovahh - LabVIEW Overlord
    If 10 out of 10 experts in any field say something is bad, you should probably take their opinion seriously.

  • Problem using events to control robot

    We are using an event structure to control a robot. As you see in the included example, we are using the serial port to transmit data to the robot (actually hyper terminal for now). NOw that the last event has been added (including the graph at lower right), the VI stops responding and must be aborted whenever a button is pressed more than twice in a row. Perhaps the problem is that the serial port is getting overwhelmed (though we are only sending 4 bytes on each button click).
    The graph event is taken from the vi called "Draw Graph With Events" that is included with labVIEW. However, instead of drawing on the graph, we send the coordinates to the robot. When the user clicks on the graph first, it works as intended, but then the
    buttons don't work and vice versa.
    Thanks for any help you can give.
    Sean and Josh

    sorry, I've had a problem posting it. I should be able to put it up soon. Please check back if you can!

  • Locked panel using event structure

    Hi!
    I'm using an event structure block to run a sequence only when a value of a control has changed.....when I edit this event I set the option NOT to lock the front panel.
    When I run the vi's I can change the controls of the front panel......but all the code outside of the event structure block does'nt run....what i have to do?
    I've attached a simple example.....boolean2 can change his value but the code is not executed
    Thanks in advance
    Larson
    Attachments:
    example_event_error.vi ‏42 KB

    hi there
    the while-loop waits for all the code contained in it to finish until it turns again. the event-structure has no time-out case defined, so if "Boolean" dosn't change it waits eternally. that's why the "Boolean 2" seems to be locked, because this code is not executed any more until the next turn of the while loop.
    add a timeout-event (event source = Application) and connect the event timeout (e.g. 100 ms). be aware that the reaction to a change of "Boolean 2" takes up to timeout ms. another option is to put the code inside the timeout-case.
    best regards
    chris
    Best regards
    chris
    CL(A)Dly bending G-Force with LabVIEW
    famous last words: "oh my god, it is full of stars!"

  • Use event structure and while loop in parallel

    Hello, I would like to use an event structure in parallel with a while loop. I have a camera that needs to constantly take pictures and I have that setup in the while loop. I also however need to do other functions in conjunction with the picture taking. I have about 50 or so events that need to have access to while the pictures are taken. Is there any way to do this? If not is there any way to have a global stop variable that is attached to all 50 of the events. I know I can do this the hard way and have each boolean event in the event structure be attached to the while loop stop control. This is however very inefficient. I would also like to know if I can simply use a mouse click as the stop of the while loop. Am I able to have a variable that goes from false to true on mouse click without using the event structure to do this? Thanks.

    Yes, just place the event structure in a second while loop.
    Add a stop button to the other while loop and add an event for the stop button to stop both loops. For a simple example, see my VI posted here:
    http://forums.ni.com/ni/board/message?board.id=170&message.id=176367&jump=true
    Simply add more event cases as needed.
    LabVIEW Champion . Do more with less code and in less time .

  • Cut text using event structure

    Hi everyone.
    I'm making a project with LV Student E. 7.1.1. I have an event structure, its function is scanning a value change in a "control text". Any change in the control text is detected by the event structure, except when I CUT the text (selecting part of the text and presing CTRL+X). The NEW VALUE isn't detected!!! Somebody knows why?

    It works if Update Value while Typing is not checked, provided you change the focus after the cut. But then you do not get events for each character as entered.
    It works as you would expect in LV8.
    Lynn

Maybe you are looking for

  • Lumia 1520 radio issues

    I recieved an update on my 1520 and the reboot problem I was having seems to have stopped. YEA!  BUT - now I'm having radio issues.  My Bluetooth will just turn off at random times, sometimes in middle of a conversation.  Also, my wifi will not recon

  • Is there an hp wireless printer that uses 21 & 22 ink?

    I have an old hp printer and want to purchase a wireless. I have ink for the old printer can I use on a new hp wireless printer?

  • Problem using mplayer [solved]

    Hi - I'm trying to run mplayer through its gui gmplayer. It doesn't run either from my normal user account or from root. From my user account I get this - process:2900): Gtk-WARNING **: This process is currently running setuid or setgid. This is not

  • Re calicutae values

    Hi Friends, i recently came accross an issue, actually for asset our users uploade from legacy in 2008 and in the same year they posted all the depriciation and later in 2009 there is nothing to depriciate. Now in 2010 they are trying to scrap it, th

  • Password export server 3.1 - 64x link broken

    i can't download the file PES 3.1 (i need 64x) http://go.microsoft.com/fwlink/?LinkId=147653 it forward  me to: http://www.microsoft.com/library/errorpages/smarterror.aspx if there is another location , where i can download it? Thanks,