Suddenly my iMac G5 has stopped printing to my Kyocera-Mita FS1010 laser printer. The printer has done over 6,000 pages in this set-up.
The printer is set as USB to an Airport Express, the computer is an iMac G5 running Mac OS X (10.4.11).
The message in the print window is The process "cgpdftops" stopped unexpectedly with status 1.
the cups log is:
I [11/Nov/2008:16:41:57 +1100] Adding start banner page "none" to job 2000.
I [11/Nov/2008:16:41:57 +1100] Job 2000 queued on 'KyoceraFS1010' by 'ian'.
I [11/Nov/2008:16:41:57 +1100] Started filter /usr/libexec/cups/filter/cgpdftops (PID 1625) for job 2000.
I [11/Nov/2008:16:41:57 +1100] Started filter /usr/libexec/cups/filter/pstops (PID 1626) for job 2000.
I [11/Nov/2008:16:41:57 +1100] Started filter /usr/libexec/cups/filter/kyofilter (PID 1627) for job 2000.
I [11/Nov/2008:16:41:57 +1100] Started backend /usr/libexec/cups/backend/mdns (PID 1628) for job 2000.
E [11/Nov/2008:16:41:57 +1100] [Job 2000] Couldn't create CGPS Context. The likely problem is a permissions problem with the /tmp directory.
E [11/Nov/2008:16:41:57 +1100] PID 1625 stopped with status 1!
I [11/Nov/2008:16:41:57 +1100] Hint: Try setting the LogLevel to "debug" to find out more.
I ran disk utility to fix permissions, but the printing didn't work
I booted from the install disk and repaired the disks (no problems found)
I am now able to print using Adobe Reader, but not Microsoft Word or TextEdit (the only two I have tested)
Printing to my inkjet printer works fine for all applications.
I desperately need help as I have heaps of stuff to print for a meeting this Friday.
Thanks
Ian
I have completed all you suggested, including re-installing drivers. The result is the same.
The printer is physically attached to my Airport Extreme as a USB Printer.
I can print successfully to the printer from the iMac G5 when using Adobe Reader.
I cannot print using Word, Excel, TextEdit, Safari, Mail or Preview using iMac G5. Others not tested.
I can print from my MacBook to the printer for every application thus tested.
Thus there is nothing wrong with the Printer, nothing wrong with the Airport Extreme.
The problem lies within the iMac G5 and the software/server used by the G5 to print. Presumerably the Adobe Reader prints using its own software/server.
What else can I do?
Ian
Similar Messages
-
Printing Problem - the process "mdns" stopped unexpectedly with status 1
I have been trying to get my Epson Stylus rX620 to print wirelessly for a while. It actually worked once and printed two separate documents. Then however it decided not to work any longer and it seems that nothing I do changes it. The same error message appears each time in the print monitor:
the process "mdns" stopped unexpectedly with status 1
It has printed wirelessly with the same equipment. It is attached to an airport express that is linked to extend my wireless network from an Airport Extreme. It has no problem printing when the USB cable is plugged in directly. I have tried everthing that I can think of. Any ideas??Hi John,
Okay, that was some new information...
Given that the hub is causing the problem then I would concentrate on testing it. Try connecting the Mac and the printer directly to the hub. Ensure the IP addresses of each device (Mac and Printer) are set to the same subnet (if printing via TCP/IP) or if AppleTalk is being used, make sure it is enabled on both devices.
You may also have to create a new printer. When you had the printer connected to the USB port of the AEBS, it will have been configured as a local device but printing via a virtual USB port. When the printer was connected to the hub, it would have been configured as a network device.
If this works then at least you know that the hub and the network cables are okay. The next step would be to ensure the AEBS, the printer and the Mac are all set to use the same protocol.
If they are all correct then try deleting the printer from the Printer List, running the Reset Printing System function and adding the network printer again. If you are using TCP/IP, you could even try pinging the printer to ensure the path to the printer is open.
Regards,
Paul -
MAC OS-X 10.4.11 PRINTER SAMSUNG SCX-4521 SAMSUNG CLX-3185 The process "rastertoqpdl" stopped unexpectedly with status 1
Hi Paolo,
Might try these two...
Mac OS X: About the Reset Printing System feature ...
http://support.apple.com/kb/HT1341?viewlocale=en_US
Might try Printer Setup Repair 5.1...
http://www.fixamac.net/software/index.html -
Question: MacBooK won't print PDF files, after selecting print it states; The process "pstopdffilter" stopped unexpectedly with status 1. I am currently using a HP Deskjet 4400 series printer and it works fine with all our other lap top computers. Thanks for any help.
The pictwpstops filter on OS X machines, converts the job to straight Postscript before the normal CUPS filters get it.
If the Adobe APPs have a choice of what kind of PS to send, like Binary or ASCII, try toggling that setting to the opposite of what it is.
Though, if a reboot fixed it then likely the problem was a remporary bit flip, which may or may not happen again. -
Our C8100 printer has worked well with our wireless setup for a few years. It is now not printing from any of our home computers (wireless is working fine on these Mac's). I've already turned off both computers and printer, waiting a few minutes and turned them back on.
Message on computer screen -- The process "usb" stopped unexpectedly with status 81. What does this mean?Yes it is a photosmart C6380 all in one
You are lucky. That model gives you an option not offered on cheaper printers.
You could abandon the USB connection completely and use ethernet to print. That model has, in addition to USB, an ethernet (or "network") port and wireless connectivity. Wireless can be flaky but ethernet is an amazing way to print--faster and more stable that using USB. The port should should be just above or below the USB port.
If your computer is already connected to the internet via ethernet, you can get an inexpensive ethernet router to create enough ports. The router goes between your modem and the computer gear. One router port is usually marked "WAN" and is where you connect an ethernet cable going from the modem. The router will have several other ports marked "LAN" that those connect yo you computer equipment.
You are basically splitting one ethernet line into several. If you have only the iMac and the HP printer, each one would connect to its own LAN port and you can print without USB issues. Normally setting up a wired router takes no software and no tweaking on your part. You connect the wires and it's running.
Here's a start on learning about home networking. In teh picture, what's labeled "gateway" is the router.
http://en.wikipedia.org/wiki/Home_network -
Unable to print: "hppostprocessing" stopped unexpectedly with status 2
Hello
I have several printers installed in my mac and have used since ever without any problem. Lately i tried to install a new HP photo-printer in the printer setup but not managed. The problem is that since then, i can't use any of my previously used printers. For any print i try with any of the printers i used before i get the systematic message:
"The process "hppostprocessing" stopped unexpectedly with status 2"
and nothing get printed, the job just dissapears from the queue.
Any hint?
thanks in advance
Diana1Thanks a lot for the link.
The best tip was using Printer Setup Repair:
http://www.fixamacsoftware.com/software/psr5/PSR5ug/512.html
This allowed me to realise that all, and only, the HP drivers had disappeared from my Mac- don;t know how...
Anyway, i installed them from HP:
http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en &cc=us&prodTypeId=18972&prodSeriesId=412144&prodNameId=412155&swEnvOID=219&swLan g=8&mode=2&taskId=135&swItem=lj-57300-1
And know all seems OK
Thanks a lot
Diana1 -
Network printer error: the 'ipp' process stopped unexpectedly with status 1
i have [3] macs connected to my studio airport extreme network. i have a powerbook G4, with our plotter and epson photo R1800 connected to it. my mac book pro can print to the epson just fine, but my primary workstation [G5] will not print to it. i get an error message "the 'ipp' process stopped unexpectedly with status 1". please help, i need to print.
- all printers are excessable and work via the airport network
- the printer is available in the shared printer list [duh]
- as stated above the printer connection trys to open than shuts down, over and over.
- the epson use to be connected directly to the G5 and worked fine, the G4 as the proper driver and can print files fine.You might try checking the Console log (in Utilities/Console) and look to see if you have this error:
Dec 19 00:22:33 PowerBook crashdump[367]: PrintJobMgr crashed
Dec 19 00:22:33 PowerBook crashdump[367]: crash report written to: /Library/Logs/CrashReporter/PrintJobMgr.crash.log
You can also look in the above referenced /Library/Logs/CrashReporter/PrintJobMgr.crash.log file for any Exception for the PrintJobMgr process.
This currently seems to only affect PPC but not Intel processors. Is this the same for your case?
Message was edited by: kae -
How do I fix it :: pictwpstops stopped unexpectedly with status 1
I get this message only when printing from Quark
pictwpstops stopped unexpectedly with status 1
I have deleted and replaced all ppd's and drivers relevant to the Xerox and have re-installed QuarkXpress 6.5 an it still does it I dont't have the problem with any other app, does anyone know how to fix this, it's sending my insane!!!!!!
[email protected]'pictwpstops' stands for 'PICT with PostScript'. PDF is the standard spool file format, but for backward compatability with applications like Quark that generate their own PostScript, the 'pictwpstops' filter is used to create the spool file.
As has been mentioned in these forums, corrupt Fonts can cause this error as can permissions.
The first thing I would do is open Disk Utility and run Repair Disk Permissions.
If the error continues after that has been performed, then look at your Font Book for duplicate fonts (marked with a dot). OS X loads fonts in an order based on the search path, the users library first, then the all users library and then the system library. You might have a case of your user font conflicting with other fonts, especially if you are using a font management utility.
Regards,
Paul -
Hello All
We have a server 2008 R2 HyperV server and during the last few months it started to reboot randomly.
Initially we thought its related to the issue fixed by the following hotfix so we applied it but even with the hotfix it still keeps rebooting.
http://support.microsoft.com/kb/2732595
Unlike what's mentioned in the hotfix , the faulting module is not "ntdll.dll" but "msvcrt.dll".Also came up with the following indication the reboots could be related to KB2871997 but that update is not installed
on this system.
Following are the events from system log.
Log Name: System
Source: LsaSrv
Date: 2/9/2015 11:58:12 PM
Event ID: 5000
Task Category: None
Level: Error
Keywords:
User: SYSTEM
Computer: HV2008-Host
Description:
The security package Kerberos generated an exception. The exception information is the data.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="LsaSrv" Guid="{199FE037-2B82-40A9-82AC-E1D46C792B99}" />
<EventID>5000</EventID>
<Version>0</Version>
<Level>2</Level>
<Task>0</Task>
<Opcode>0</Opcode>
<Keywords>0x8000000000000000</Keywords>
<TimeCreated SystemTime="2015-02-10T04:58:12.415529200Z" />
<EventRecordID>8091130</EventRecordID>
<Correlation />
<Execution ProcessID="736" ThreadID="5888" />
<Channel>System</Channel>
<Computer>HV2008-Host</Computer>
<Security UserID="S-1-5-18" />
</System>
<EventData>
<Data Name="Package">Kerberos</Data>
<Binary>050000C00000000000000000000000001111F6FEFE070000020000000000000000000000000000008EEB1802000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000</Binary>
</EventData>
</Event>
Log Name: System
Source: USER32
Date: 2/9/2015 11:58:24 PM
Event ID: 1074
Task Category: None
Level: Information
Keywords: Classic
User: SYSTEM
Computer: HV2008-Host
Description:
The process wininit.exe has initiated the restart of computer HV2008-HOST on behalf of user for the following reason: No title for this reason could be found
Reason Code: 0x50006
Shutdown Type: restart
Comment: The system process 'C:\Windows\system32\lsass.exe' terminated unexpectedly with status code 255. The system will now shut down and restart.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="USER32" />
<EventID Qualifiers="32768">1074</EventID>
<Level>4</Level>
<Task>0</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2015-02-10T04:58:24.000000000Z" />
<EventRecordID>8091132</EventRecordID>
<Channel>System</Channel>
<Computer>HV2008-Host</Computer>
<Security UserID="S-1-5-18" />
</System>
<EventData>
<Data>wininit.exe</Data>
<Data>HV2008-HOST</Data>
<Data>No title for this reason could be found</Data>
<Data>0x50006</Data>
<Data>restart</Data>
<Data>The system process 'C:\Windows\system32\lsass.exe' terminated unexpectedly with status code 255. The system will now shut down and restart.</Data>
<Data>
</Data>
<Binary>06000500000000000000000000000000000000000000000000000000000000000000000000000000</Binary>
</EventData>
</Event>
Following are the events from Application logs.
Log Name: Application
Source: Application Error
Date: 2/9/2015 11:58:14 PM
Event ID: 1000
Task Category: (100)
Level: Error
Keywords: Classic
User: N/A
Computer: HV2008-Host
Description:
Faulting application name: lsass.exe, version: 6.1.7601.22653, time stamp: 0x534893ed
Faulting module name: msvcrt.dll, version: 7.0.7601.17744, time stamp: 0x4eeb033f
Exception code: 0xc0000005
Fault offset: 0x0000000000001111
Faulting process id: 0x2e0
Faulting application start time: 0x01d03c91dbe5854f
Faulting application path: C:\Windows\system32\lsass.exe
Faulting module path: C:\Windows\system32\msvcrt.dll
Report Id: 6af0ff3d-b0e1-11e4-83ca-0026b9340d61
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="Application Error" />
<EventID Qualifiers="0">1000</EventID>
<Level>2</Level>
<Task>100</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2015-02-10T04:58:14.000000000Z" />
<EventRecordID>267648</EventRecordID>
<Channel>Application</Channel>
<Computer>HV2008-Host</Computer>
<Security />
</System>
<EventData>
<Data>lsass.exe</Data>
<Data>6.1.7601.22653</Data>
<Data>534893ed</Data>
<Data>msvcrt.dll</Data>
<Data>7.0.7601.17744</Data>
<Data>4eeb033f</Data>
<Data>c0000005</Data>
<Data>0000000000001111</Data>
<Data>2e0</Data>
<Data>01d03c91dbe5854f</Data>
<Data>C:\Windows\system32\lsass.exe</Data>
<Data>C:\Windows\system32\msvcrt.dll</Data>
<Data>6af0ff3d-b0e1-11e4-83ca-0026b9340d61</Data>
</EventData>
</Event>
Log Name: Application
Source: Windows Error Reporting
Date: 2/9/2015 11:58:23 PM
Event ID: 1001
Task Category: None
Level: Information
Keywords: Classic
User: N/A
Computer: HV2008-Host
Description:
Fault bucket , type 0
Event Name: APPCRASH
Response: Not available
Cab Id: 0
Problem signature:
P1: lsass.exe
P2: 6.1.7601.22653
P3: 534893ed
P4: msvcrt.dll
P5: 7.0.7601.17744
P6: 4eeb033f
P7: c0000005
P8: 0000000000001111
P9:
P10:
Attached files:
C:\Windows\Temp\WER5001.tmp.appcompat.txt
C:\Windows\Temp\WER535C.tmp.WERInternalMetadata.xml
C:\Windows\Temp\WER53DA.tmp.hdmp
C:\Windows\Temp\WER6690.tmp.mdmp
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_lsass.exe_3c1aa5eeba75bf26fcebc4f54e714efe7b5162a2_cab_20a56871
Analysis symbol:
Rechecking for solution: 0
Report Id: 6af0ff3d-b0e1-11e4-83ca-0026b9340d61
Report Status: 0
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="Windows Error Reporting" />
<EventID Qualifiers="0">1001</EventID>
<Level>4</Level>
<Task>0</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2015-02-10T04:58:23.000000000Z" />
<EventRecordID>267650</EventRecordID>
<Channel>Application</Channel>
<Computer>HV2008-Host</Computer>
<Security />
</System>
<EventData>
<Data>
</Data>
<Data>0</Data>
<Data>APPCRASH</Data>
<Data>Not available</Data>
<Data>0</Data>
<Data>lsass.exe</Data>
<Data>6.1.7601.22653</Data>
<Data>534893ed</Data>
<Data>msvcrt.dll</Data>
<Data>7.0.7601.17744</Data>
<Data>4eeb033f</Data>
<Data>c0000005</Data>
<Data>0000000000001111</Data>
<Data>
</Data>
<Data>
</Data>
<Data>
C:\Windows\Temp\WER5001.tmp.appcompat.txt
C:\Windows\Temp\WER535C.tmp.WERInternalMetadata.xml
C:\Windows\Temp\WER53DA.tmp.hdmp
C:\Windows\Temp\WER6690.tmp.mdmp</Data>
<Data>C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_lsass.exe_3c1aa5eeba75bf26fcebc4f54e714efe7b5162a2_cab_20a56871</Data>
<Data>
</Data>
<Data>0</Data>
<Data>6af0ff3d-b0e1-11e4-83ca-0026b9340d61</Data>
<Data>0</Data>
</EventData>
</Event>
Log Name: Application
Source: Windows Error Reporting
Date: 2/9/2015 11:58:22 PM
Event ID: 1001
Task Category: None
Level: Information
Keywords: Classic
User: N/A
Computer: HV2008-Host
Description:
Fault bucket , type 0
Event Name: APPCRASH
Response: Not available
Cab Id: 0
Problem signature:
P1: lsass.exe
P2: 6.1.7601.22653
P3: 534893ed
P4: msvcrt.dll
P5: 7.0.7601.17744
P6: 4eeb033f
P7: c0000005
P8: 0000000000001111
P9:
P10:
Attached files:
C:\Windows\Temp\WER5001.tmp.appcompat.txt
C:\Windows\Temp\WER535C.tmp.WERInternalMetadata.xml
C:\Windows\Temp\WER53DA.tmp.hdmp
C:\Windows\Temp\WER6690.tmp.mdmp
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_lsass.exe_3c1aa5eeba75bf26fcebc4f54e714efe7b5162a2_cab_20a56871
Analysis symbol:
Rechecking for solution: 0
Report Id: 6af0ff3d-b0e1-11e4-83ca-0026b9340d61
Report Status: 4
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="Windows Error Reporting" />
<EventID Qualifiers="0">1001</EventID>
<Level>4</Level>
<Task>0</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2015-02-10T04:58:22.000000000Z" />
<EventRecordID>267649</EventRecordID>
<Channel>Application</Channel>
<Computer>HV2008-Host</Computer>
<Security />
</System>
<EventData>
<Data>
</Data>
<Data>0</Data>
<Data>APPCRASH</Data>
<Data>Not available</Data>
<Data>0</Data>
<Data>lsass.exe</Data>
<Data>6.1.7601.22653</Data>
<Data>534893ed</Data>
<Data>msvcrt.dll</Data>
<Data>7.0.7601.17744</Data>
<Data>4eeb033f</Data>
<Data>c0000005</Data>
<Data>0000000000001111</Data>
<Data>
</Data>
<Data>
</Data>
<Data>
C:\Windows\Temp\WER5001.tmp.appcompat.txt
C:\Windows\Temp\WER535C.tmp.WERInternalMetadata.xml
C:\Windows\Temp\WER53DA.tmp.hdmp
C:\Windows\Temp\WER6690.tmp.mdmp</Data>
<Data>C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_lsass.exe_3c1aa5eeba75bf26fcebc4f54e714efe7b5162a2_cab_20a56871</Data>
<Data>
</Data>
<Data>0</Data>
<Data>6af0ff3d-b0e1-11e4-83ca-0026b9340d61</Data>
<Data>4</Data>
</EventData>
</Event>
Would really appreciate if someone can point us to the correct direction on how to get this issue sorted.
Regards,
DhanushkaHi Sir,
Please try the following items:
1. if ther is anti-virus installed , please uninstall it temporarily
2. run " sfc /scannow "
3. keep windows up-to-date
4. if you updated some hardware driver please roll it back
5. if the issue persists , please use windows installation media to perform inplace-upgrade for the system
Also please refer to reinstall C++ runtime within the similar thread:
https://social.technet.microsoft.com/Forums/windows/en-US/bf69eeff-24c4-499f-b280-b6a3098f4f9f/problem-with-msvcrtdll-version-70760117744?forum=w7itprogeneral
Best Regards,
Elton Ji
Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] . -
AC100 - the process android.process.acore stopped unexpectantly
Our AC100 suffers from frequent and annoying messages: the process android.process.acore stopped unexpectantly (well it is said in Dutch, so I hope the translation is right). After googeling I have found many people with the same problems (but for other devices than a computer from Toshiba), and it seems that the only solution is resetting the original settings (after making a back-up).
But since all downloaded widgets and applications will be gone then, I am looking for another possibility. Does anyone have experience with this message? How did you solve the problem?
And who knows how this problems starts?Hi
I would also recommend setting the Android back to factory settings. The widget could be saved on external source before setting the notebook to factory settings. -
'Services.exe Terminated Unexpectedly with status code 128' on SAP server
get message 'Services.exe Terminated Unexpectedly with status code 128' on SAP Server when start windows 2000. & SAP server shut down
Hi,
Please check the link below.
http://support.microsoft.com/kb/318447
Rgds,
Suman -
BO4 - 30270+ Frequent webi processing server crashes/processing server stopped unexpectedly
Hi ,
We are seeing relatively frequent 30270 error messages - when check event logs often see them preceded by webi porcessing server stopped unexpectedly messages.
Have split the aps as per best practice and have 4 webi processing servers ( 2 on each node)
Any thoughts?
Faulting application name: WIReportServer.exe, version: 14.0.8.1229, time stamp: 0x525dbf5c
Faulting module name: ntdll.dll, version: 6.1.7601.17725, time stamp: 0x4ec4aa8e
Exception code: 0xc0000374
Fault offset: 0x00000000000c40f2
Faulting process id: 0x12dc
Faulting application start time: 0x01cf32eaa201a083
Faulting application path: C:\bo4\SAP BusinessObjects Enterprise XI 4.0\win64_x64\WIReportServer.exe
Faulting module path: C:\Windows\SYSTEM32\ntdll.dll
Report Id: e4a37101-9efd-11e3-9ebb-000c29ccd95d
30270 message soften preceded by below in event logs (estimate 80% of time)
[User Name: <username>]
Server Intelligence Agent: server<server_name>.WebIntelligenceProcessingServer2 stopped unexpectedly.
Node Name: <node_name>]Hi Philip,
I can feel like few of the heavy webi reports in your environment causing webi processing server down.
1) first we need to find which reports are causing the issue.
2) Enable monitoring to know the failure status of WIPC by email
3) Try to enable audit and capture the reports which are consuming more data and running when WIPS moved to stopped state
Then you will come to know the report with help of audit .
I have noticed the similar issue and noticed few reports which are retrieving more no of records and More no input cantrols in the report caused WIPS down. -
IDOC is not processing in R/3 with status 64(Urgent)--Production issue.
Dear Folks,
Here we are implementing MIRROR sytem for data extraction in to BIW.
I had gone through the steps in PDF file(How to minimize down thime for Delta Initialization) which has given by SAP.
These are following steps I had performed in BW production
1. Using RSADMIN transcation- Assigned one user as a Debugging user.
2. With the Debugging user Created one infopackage on Purhcasing ITM datasource--
In data selection tab, I given date as from 2002 to 2003
In Update tab, I selected update mode as Initialize Delta process- without data transfer and Uncheck Update Data in master system immediately
In schedule tab I selected option Start Data load immediately then Start extraction.
3.Data was requested and It was intialized properly with green status 1 from 1 Records.
4. In details tab Request, Extraction, transfer(IDOC and TRFC), Processing everything in Green color.
5.As per document I have checked in R/3 for IDOC with status 64 using transaction BD87/WE05
Problem is that IDOC is not processing in R/3 system. for that IDOC I have checked in BW montior screen using the option <b>IDOC list in Source sytem</b>, here also it is not showing any IDOCs.
Please let me know why BW sytem is not sending any IDOCs to source sytem.Is there any settings I could have miss in BW aswell as in R/3 system.
Note: In BW production I successfully loaded master data from R/3. aswell as I triggered infopackage-Initialization with data transfer, it is showing IDOC number properly in R/3 system.
Points is Assured for all replies.Hi,
- check you RFC destination (normal test + authorization test)
- Check you partner profiles in WE20 and its ports WE21
- from the source system tree (RSA13) right click your source system and perform a check
- the best is to restore your source R/3 source system from BW (right click on it ans select RESTORE); you'll need to be able to log in the source system as an admin as well as opening the source system for customizing in SCC4 so that BW can recreate the correct partner parameters automatically; the best is to do that with your basis group.
hope this helps,
Olivier. -
Want to do mass processing for inspection lots with status SPRQ
Hello,
My company using early lot creation for 04 inspection type. We have thousands of inspection lots with status "UD ICCO SPRQ PRII PRSI STUP". Now due to SPRQ status, system is not closing process orders associated with thousands of inspection lots.
Is there any transaction where I can do mass processing of inspection lots to change the status "SPCO" from "SPRQ"?
Thanks
BhaveshDear Bhavesh
You may have to modify the standard program to do so. Modify this program RQEVAI30.
This can help you
Regards
gajesh -
Process in SM35 cannot be processes after stopping unexpectedly.
Hello,
I was running a process through SM35 and pc just expectedly turned off.
After reloging again I tried to rerun the same process in SM35.
I get an error "The requested session cannot be processed
Message no. 00309
Diagnosis
Only sessions with the statuses 'still to be processed' or 'contains errors' can be processed."
Please suggest what to do.
Regards
VijayGot the solution,
Just released it and processed again.
Regards
Vijay
Maybe you are looking for
-
I have a new ipod and added all my apps to it. When I sign in to Words with Friends it says that "user name is already in use" because it is linked to my old ipod. How can I use the same user name with my new ipod?
-
How to revert back to the old code in NWDI ??
Hi, I have done some changes to one of the DC and have released the activities and imported that in consolidation tab in transport studio of CMS. Now my client do not want the changes we did, and he is asking me to revert back to the code that was pr
-
Xf86homepage opens up my home directory
Hi, I use Gnome and in Keyboard Shortcuts / Launch web browser is tied to xf86homepage. So when I use this extra key on my keyboard it opens up firefox (as it is supposed to do) but opens a new tab with my home directory. I would like to see the last
-
Send HR Form (tcode Pe51) to employee email
Hi friends, Is it possible to send the HR form PF01 (of the remuneration statement report RPCEDTP0) defined in tcode PE51 by email, to the employees, entering, for example, email address in infotype 0105 (communication), subtype 0010 (email)? I mean,
-
Newbie - help with a SQL query for a bar chart - Originally posted in APEX
I originally posted this in the APEX forum but someone there suggested this is more of a SQL question. Anyone out there who can provide some assistance? Hi, I'm a new user on APEX with no real SQL knowledge and I'm trying to build a dashboard with c