Producer consumer design pattern

Hello,
I am trying to build a simple program that does the following:
1. when program starts, the indicator is initialized to -999
2. when Measure button is clicked, the indicator shows random number continuously.
3. when Save button is clicked, the indicator shows 1
I use the event-based producer-consumer design pattern and it works great. However, I cannot find a way to allow the CONTINUOUSLY generating of random number when Measure is clicked. Can someone shed a light on it? Thanks a lot for the help. 
Attachments:
CommandList.ctl ‏6 KB
Untitled 1.vi ‏25 KB

One simple way to do it is to use the Timeout event case. You can modify the timeout value based on what events have occurred. See attached mod.
Not saying this is the best way. Kind of depends on where the program goes from here. 
Attachments:
Untitled 1-2 MOD.vi ‏27 KB

Similar Messages

  • Producer/Consumer Design Pattern with Classes

    I'm starting a new project which involves acquiring data from various pieces of equipment using a GPIB port.  I thought this would be a good time to start using Classes.  I created a GPIB class which contains member data of:  Address, Open State, Error; with member vis such as Set Address, Get Address, Open, Close...general actions that all GPIB devices need to do.  I then created a child class for a specific instrument (Agilent N1912 Power Meter for this example) which inherits from the GPIB class but also adds member data such as Channel A power and Channel B power and the associated Member Functions to obtain the data from the hardware.  This went fine and I created a Test vi for verfication utilizing a typical Event Structure architecture. 
    However, in other applications (without classes) I  typically use the Producer/Consumer Design Pattern with Event Structure so that the main loop is not delayed by any hardware interaction.  My queue data is a cluster of an "action" enum and a variant to pass data.  Is it OK to use this pattern with classes?  I created a vi and it works fine and attached is a png (of 1 case) of it.
    Are there any problems doing it this way?
    Jason

    JTerosky wrote:
    I'm starting a new project which involves acquiring data from various pieces of equipment using a GPIB port.  I thought this would be a good time to start using Classes.  I created a GPIB class which contains member data of:  Address, Open State, Error; with member vis such as Set Address, Get Address, Open, Close...general actions that all GPIB devices need to do.  I then created a child class for a specific instrument (Agilent N1912 Power Meter for this example) which inherits from the GPIB class but also adds member data such as Channel A power and Channel B power and the associated Member Functions to obtain the data from the hardware.  This went fine and I created a Test vi for verfication utilizing a typical Event Structure architecture. 
    However, in other applications (without classes) I  typically use the Producer/Consumer Design Pattern with Event Structure so that the main loop is not delayed by any hardware interaction.  My queue data is a cluster of an "action" enum and a variant to pass data.  Is it OK to use this pattern with classes?  I created a vi and it works fine and attached is a png (of 1 case) of it.
    Are there any problems doing it this way?
    Including the error cluster as part of the  private data is something I have never seen done and ... well I'll have to think about that one.
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Producer/Consumer Design Pattern + DAQmx + Event Structure

    Dear community users,
    at the moment I try to implement the Producer/Consumer Design Pattern into my current project. For this purpose I am trying to make a "minimal-example" in which I use the Producer/Consumer Design Pattern for the data acquisition and analysis (display in GraphXY, calculation etc..) process. In the Producer Loop I perform the data readings via DAQmxRead.VI and in the Consumer Loop, in this example only, I display the data in a GraphXY. At the same time I want to control the data acquisition via an Event Structure, for example Start Measurement/Stop Measurement Buttons. To configure the measurement time, for example if the user only wants to measure 150 sec, I use the Time Out Event of the Event Structure. This is a technique which is often used, when data acquisition and Event Structures are used at the same time (Excuse me if this is wrong!). Due to understand the Producer/Consumer Design Pattern I looked up in the Template\Framework of LabVIEW.
    In the attachment you will find my "minimal-example", which -sadly-, not working. What should I do ? 
    Thank you.
    Best regards,
    tugrul öztürk
    Attachments:
    daqEngine_PCP.vi ‏35 KB

    Your VI will never stop due to the Ok Button that stops the producer loop is read OUTSIDE of the loop.  Add an event case for it.
    Move the Start and the Ok Button inside of their respective event cases.  This will allow the latch to reset when they are read.
    Change the Ok Button to a stop button.
    Use a Greater Or Equal instead of Equal for the measurement time comparison.  What if somebody randomly changes it to 0 on you?  Again, you will never stop.
    Is the DAQ only supposed to read for "Measurement Time".  Right now, it constantly reads.  So if you don't use the DAQmx Read, you will get a buffer overflow error.  You need to put the DAQmx Start Task inside of the Start event case and then the Stop DAQmx Task inside of the Timeout event case when the measurement time is exceeded.  You should also perform the read regardless inside of the Timeout event case.
    I HATE telling the consumer loop to stop by destroying the queue.  You can look data that way.  Instead, send something an empty array.  In the consumer, check for an empty array.  If it is empty, stop.  Destroy the queue only AFTER BOTH LOOPS HAVE COMPLETED.
    You should also report your errors in some way.  Simple Error Handler at the minimum.
    Since you are using Continous Samples, don't limit the buffer.  Leave the Samples per Channel unwired on the DAQmx Timing VI.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Could Buffer replace the Queue in Producer/Consumer Design Pattern

    Hello,
    I have a question that the task of Buffer is to store the data and the queue is also of the same so could we use the Buffer inplace of queue in a Producer/Consumer Design Pattern.
    Solved!
    Go to Solution.

    No, those buffer examples are not nearly equal to a queue and will never ever "replace" queues in producer/consumer.
    The most important advantage of queues for producer/consumer (which none of the other buffer mechanics share) is that it works eventbased to notify the reader that data is available. So if you would simply replace the queue by overly elaborate buffer mechanics as you attached to your last post, you will lose a great deal of the the purpose using producer/consumer.
    So, to compare both mechanics:
    - Queue works eventbased, whereas the buffer example does not.
    - Queue has to allocate memory during runtime if more elements are written to the queue than dequeued. This is also true for the buffer (it has to be resized).
    - Since the buffer is effectively simply an array with overhead, memory management is getting slow and messy with increasing memory fragmentation. Queues perform way better here (but have their limits there too).
    - The overhead for the buffer (array handling) has to be implemented manually. Queue functions encapsulate all necessary functionality you will ever need. So queues do have a simple API, whereas the buffer has not.
    - Since the buffer is simply an array, you will have a hard time sharing the content in two parallel running loops. You will need to either implement additional overhead using data value references to manage the buffer or waste lots of memory by using mechanics like variables. In addition to wasting memory, you will presumably run into race conditions so do not even think about this.
    So this leads to four '+' for the queue and only one point where "buffer" equals the queue.
    i hope, this clears things up a bit.
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • State Machine and producer consumer design patterns

    Hi!
    In my application I am using state machine(for top level VI) and producer consumer(for subVIs) design patterns throught out.
    If there is no activity on the front panel for 1min then the ideal state is invoked. Following are the situation of the ideal state:
    1. It checks for any hardware present on the network . If no hardware is found on the network within 1 min then the application and LabVIEW exits.
    2. While the ideal state checks for the hardware, and user clicks on any front panel button then it should exit the ideal state. The control
    should be in the respective button state.
    I am able to achive the point#1 mentioned above but could not get the point #2 to work. I am including the snap shot of
    the state machine(default case) and prouducer consumer(deafualt state).
    Each screen has the concept of the ideal state. The only additional step in the subVIs is that when the ideal state is reached and the time has expired then it will close the subVIfront panel.It will go to the exit state of the Main(top level) VI. Thus closing the application and quitting LabVIEW.
    Any ideas or suggestions. Will multithreading and notifiers help?
    TIA
    Rachana
    Attachments:
    Sanpshot_Of_Design.zip ‏75 KB

    Hi Rachana,
    I was thinking about using event structures wherein there would an event case that would handle any value change event for any of the buttons on the front panel. But before suggesting that, I would need to know more about the Ideal State subvi( more specifically, how is it checking for any hardware present on the network and where is the one minute wait coming from?).
    Please feel free to respond to this post with your questions/comments.
    Regards,
    Ankita A.

  • Register event in producer consumer design pattern

    Hello wire workers,
    I am fairly green when it comes to dynamic event registration, so my understanding of it is probably quite flawed, but what I have implemented seems to work fine.
    Assuming a fairly typical queued producer/consumer state machine architecture.
    Up till now, I have done the dynamic event registration outside (i.e. to the left of) the UI loop, so all events get registered before the UI loop starts to run.
    My question is:
    How can I register events from inside one of the consumer loops? I cannot wire it...
    Maybe an example will make my scenario more clear.
    I have a DAQ loop (queued state machine). In the init state of this loop I want to register a digital input such that changes on a line are handled by my main event structure (in the totally separate UI loop). Is this possible?
    I look forward to hearing positive answers
    nrp
    CLA

    The best way to send data from the Consumer Loop to the Producer Loop is through User Events. What you will want to do is create a User Event whose data type is the registered DAQmx event refnum. Then when you register the DAQmx event in the Consumer Loop, fire the User Event with that new refnum and update the registration in the Producer Loop. That's probably hard to wrap your head around in words, so I'll attach a dummy example and pic below. Hope this helps!
    VI Saved in LV85.
    Message Edited by Jarrod S. on 04-21-2008 12:54 PM
    Jarrod S.
    National Instruments
    Attachments:
    DAQmx Event.vi ‏30 KB
    DAQmx Event Pic.PNG ‏38 KB

  • Producer/ Consumer Design error?

    I am learning labview as I go and little errors keep stumping me. I set up the producer/consumer design and it reads the two while loops like I want. However, when I stop the program to save it to the write to measure it gives me an error saying invalid input and highlights the dequeue. I have to queues running (one for a button and one for data) and they both do this. I tried connecting it different ways but its always the same error. Any ideas? 
    Attachments:
    2whlloopprgrm.vi ‏392 KB

    Dublicate post
    Stick to one post at a time. Do not post the same question on two different threads. 

  • First attempt at Producer Consumer Architectu​re: continuous read and dynamicall​y update parameters​.

    Hello,
    I am currently working with two instruments; an Agilent E3646A and an NI 6212 BNC. My objective is to have the 6212 to be continuously taking measurements according to predefined parameters while the E3646A's parameters can be continuously updated. This simple instrument combination is intended to help me learn the necessarry achitecture; continuous measurement, dynamic output control, and more instruments will be added in the future.
    I've previously posted on a similar, but more complicated, setup (http://forums.ni.com/t5/Instrument-Control-GPIB-Se​rial/Split-second-lag-when-controlling-two-instrum​... and was advised to try the Producer Consumer Architecture. I've found relevant literature on the site (http://www.ni.com/white-paper/3023/en/, https://decibel.ni.com/content/docs/DOC-2431), searched the forums and constructed my own VI. While my first attempt at a Producer Consumer Architecture has resolved some of the issues I was having when I first posted on the subject, however, new issues have arisen with regard to reading and stopping the VI.
    I am currently able to run the VI and update the device parameters. Previously, I would get a freeze while the instrument was being updated and could not toggle parameters until it was done. This has been resolved although the read only updates when a parameter has been updated although it is outside of the event structure. Furthermore the Stop button does not work in any context. I've also gotten occasional errors regarding the Deqeue Element but the bulk of the trouble is Error -200279 "Attempted to read samples that are no longer available" at DAQmx Read. I realize that there is a problem in my Producer Loop but haven't been able to figure out how to resolve it.
    This is my first attempt at a Producer Consumer Architecture and already I can see that it is a powerful tool. I read as much as I could and looked at the relevant examples but expected to have some issues in the beginning. Would really appreciate any advice so I can take full advantage of the architecture.
    Hope to hear from you,
    Yusif Nurizade
    Solved!
    Go to Solution.
    Attachments:
    DCe3646A_DAQ6212_Prod_Con_4_13a_2014.vi ‏89 KB

    Jon,
    Thank you for the response and the suggestions.
    I created the Local Variable for the Stop Button and moved the original into its own Event Case. It is now able to stop VI execution although I get Warning -1073676294 which I understand to be the buffer issue. The warning says that this was incurred on VISA Open for the E3646A's Initialize VI which is outside both loops, however, which I don't understand.
    I tried increasing buffer size by decreasing the Number of Samples as per suggestions I found on NI forum threads. I've brought it down as low as 1 but the graph still only updates when an Event occurs and I keep getting the same buffer error. You suggested that the problem could be that they are in the same loop; does this mean that the DAQmx read should be outside both Producer and Consumer Loops or moved into the Consumer Loop? I found a couple of links ( http://forums.ni.com/t5/LabVIEW/Producer-Consumer-​Design-Pattern-DAQmx-Event-Structure/td-p/2744450 ,  http://forums.ni.com/t5/LabVIEW/Producer-Consumer-​Architecture/td-p/494883 -first response) on dealing with an Event Structure that my own VI is based. Alternatively, I found another link ( http://forums.ni.com/t5/LabVIEW/Producer-Consumer-​Design-Pattern-DAQmx-Event-Structure/td-p/2744450 - first response) on a DAQmx Read with an Event Structure that places the graph in the Consumer Loop.
    The core of my purpose in setting up this Producer Consumer Architecture is so that I could read continuously while the instrument parameters are updated dynamically so it's very important that I understand how this works. I am particularly struggling with how the Event Structure is controlling the While Loop's Execution.
    Hope to hear form you,
    Yusif Nurizade
    Attachments:
    DCe3646A_DAQ6212_Prod_Con_4_14a_2014_Edit_I.vi ‏90 KB

  • Is this a good design pattern?

    Hi,
    I am working with a team to create an application that can acquire data from up to 24 thermcouple channels.  We plan to create a wizard to assist the user in setting up the test (specifiying stop conditions, sample rate, channels to sample, output file, and email/text notifications).  After the setup, if the user does not cancel out, then the program continues.  We have defined parallel loops and their roles, trying to fit into a producer/consumer design pattern.  I have attached the main file which shows the structure of the program.  We are trying to keep it clean and modular.  Before diving into development, we are finalizing a detailed design specification so that different people can work on each of the loops' subvis.  I was hoping that people could review the block diagram and offer suggestions for improvement or validate that we have chosen a good method of implementation.
    Notes about the block diagram
    The plan is for data driven stop conditions to be detected by Event Notifier, handled by the Main UI event, and then the Data Collector is instructed to stop (as well as the Main UI loop).  When Data Collector stops, it releases queues, the queue reference becomes invalid, and then the loops with the Dequeue will be stopped.
    I am not sure if an additonal event structure should be in the DataCollector to specifically handle the Stop button on the UI because if it is in the Main UI event structure, the DataCollector would not be stopped immediately.  This is important to stop quickly because the sample rate could be VERY long.  I understand about using an event structure instead of WAIT, but didn't know if there is an efficient way leaving it down in the Main UI event structure....????
    Data Collector is the producer, it currently only collects data and passes it on.  If the program is going to contain a start collection button, or pause/resume, I need to figure out how to handle this with the Main UI event structure.
    Event Notifier consumes data from the Data Collector.  It looks at all data and should set a flag if a stop condition is met.  The flag will be handled by the Main UI event structure to tell Data Collector to stop.  The event notifier also sends a notification to the Email/Text Caller when thresholds have been exceeded warranting a reason for the user to be notified via text or email.
    Email/Text Caller waits for notification and then calls a subVI to send an email or text with certain data and channel information.  The subVI call is lengthy, so we decided to put this in its own loop instead of a case structure inside the Event Notifier.
    Report Generator logs all collected data to a file.  A second queue was used, but uses the same data as the first.  Is this the correct implementation since two consumers need the same data?
    Main UI - handles changing of sample rate, possibly the stop button, possibly start/pause/resume of data collection.  Also handles when Event Notifier sets flag for a data driven stop condition, which then should provide a mechanism to stop the Data Collector.
    A big question that i have is.... Should the Main UI event structure just be in the Data Collector so that the loop can be stopped immediately?  All of the UI events (stop button, start/pause/resume data collection) directly effect the Data Collector.  Should the data Collector have a state machine instead?
    I feel that the 3 consumer loops (Event notifier, Email/Text Caller, and Report Generator) seem like a good implementation, but i am not confident about the Data Collector and Main UI loops.  Should they be combined?
    Solved!
    Go to Solution.
    Attachments:
    updatedMain.vi ‏13 KB

    A couple of thoughts:
    Overall it looks workable- remember to name your queus and notifiers- then you can depop the BD and launch each loop in its own sub-vi without wiring all those queues between loops- Just obtain ref to named queue.
    "Data collector" needs a supervisor to control how often the data is collected- I'm thinking a QSM with "init- collect- stop" states.  A simple timed loop could produce the "time to acq ticks" under control of the sample rate control. This puts both the DAQ init and cleanup functions within the Data Collector's perview so it aids coehesion and solves the exit without waiting for the loop to iterate.
    I'm not a fan of duplicating data- I assume analisys is pretty much just some comparisons- so it is pretty quick- Why not append summary data to the same queue? And make it a single element queue- the report loop can then inspect the queue and look for a summary data "index" - if its greater than the last index written append the darn data to the report?  Preview queue works great for these situations.
    Do not combine the UI handeler with anything else! Do you see the snag?- hint: here thar be spaghetti.  keep the functions seperated for solid scalable and maintainable code.
    One last thought:  Its getting less popular to stop loops on the error out of a dequeue.  First it returns a default element that can cause your listeners some headaches.  Second it doesn't let you run cleanup code.  Use a stop command <enum> built into the element data as an executive to determine when to stop.  We'll try to get the examples updated to show current best practices.
    Jeff

  • Producer consumer "clean up diagram" puts consumer on top of producer

    I do File > New... > VI > From Template > Frameworks > Design Patterns > Producer/Consumer Design Pattern (Events)
    Then without doing anything to the block diagram or front panel, I click on the "clean up diagram" which does the auto block diagram cleanup.  Bam! Consumer loop is put on top of Producer. 
    I tried a bunch of combinations of the Block Diagram options settings (wire spacing, move controls left, etc.) , but the "clean up diagram" always wants to put consumer loop on top of the producer loop.  How can I get labview to maintain the original loop positions?

    There is a reason a lot of use do not like to use the Block Diagram Cleanup.  It generally works for simple VIs.  But I would not use it on my top level architecture.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Recommend design pattern books

    Hi
    I work at a university and I am looking for some books on design patterns in LabVIEW, preferably for 2009.
    I am interested in state machine and master/slave design and perhaps also producer/consumer design pattern.
    Can you recommend some books on these techniques.
    Simon
    LabVIEW 8.6 / 2009 / 2010
    Vision Development Module 8.6 / 2009 / 2010
    VBAI 3.6 / 2010

    The LabVIEW Style Book by Peter Blume has a chapter devoted to discussing patterns in LV.  If you want to go generic and not pin yourself to one language, the classic of the subject is Design Patterns by Gamma, Helm, Johnson & Vlissides - that book has been on my shelf ever since I used it as a textbook over a decade ago.
    Greg
    Certifed LabVIEW Developer

  • Time Stamps in Producer/Consumer Setup

    I am trying to acquire signal from a Gas Analyzer, Flow Meter, and 3 RTDs.  My hardware is a NI 9215 and NI 9217.  I need to write the data to a file with a time stamp at which the sample was read.  The program is written in a producer/consumer setup in which the data is being acquired in the prodcuer loop and sent to the consumer loop to be written.  I can get the samples written to the file okay. However, I have not figured out how to put the time stamp in the data file correctly. I thought the time stamp was created with the corressponding measurement at the Data Acquisition VI. However, whenever I open the data file, there are only 0s in the time column.  So, I've tried to use Format/Date String to add the time stamp. I can get it to work if I place it in the consumer loop. However, the time stamp is not accurate.  It puts the same time stamp up to six digits of precision for two consecutive samples. I've tried to figure out how to add it to the producer  loop, but I don't know how to add it and the measurements to the queue at the same time. Please tell me the best way to acquire signals with the exact time stamp and write them to a file using a producer/consumer design.
     Example:
    Date             Time               RTD1     RTD2      RTD3     CO2      Flow
    5/26/07      5:20:01.25       57         56         56.5      100       0.5
    5/26/07      5:20:01.30       57         56         56.5      100       0.5
    5/26/07      5:20:01.35       57         56         56.5      100       0.5
    Attachments:
    Producer-Consumer From Scratch2.vi ‏75 KB

    Okay, I've put it in a For Loop and it will connect now. However, whenever it runs the time stamp increments for a couple seconds and then it just repeats. How do I correct this?
    Attachments:
    Producer-Consumer From Scratch2.vi ‏88 KB
    pleasework.txt ‏20 KB

  • QSM (Producer/Consumer) Template

    Hello everyone. Before I start with my project (instrument control and data acquisition) I made a template using the JKI State machine template and converted to queued based state machine with producer/consumer loop. Basically, I wanted to separate the processing i.e.. data acquisition etc. from any front panel activity i.e. button press etc. Since I've worked with JKI template quite a lot, I'm used to the idea of string based queues and the layout of the template itself, so I just modified it to better suit my needs.
    I checked the JKI Producer/Consumer design at: http://forums.jki.net/topic/1347-jki-state-machine-producer-consumer-loop/, but it wasn't quite what I wanted since if my hardware (i.e. motor) reaches a certain limit (safety issue) I have to terminate the process (easily accomplished with the above example), however, if user decides to intervene (HARD STOP), then the process wouldn't terminate on the second loop. 
    Anyway, above is just an idea of what I'm in to and attached is a template I decided to do with QSM Producer Consumer style.
    I would appreciate any comments/improvements that you might be able to do in this template.
    Thanks 
    Kas
    Attachments:
    Qued State Machine.zip ‏96 KB

    Thanks anyway.
    Regards
    Kas

  • Producer/Consumer-QSM

    Hi,
    This VI performs a instrument control. Some parameters need to be adjusted while VI is running.
    Producer/Comsumer design pattern is used to implement it. The producer catches the events of
    value change of parameters. The comsumer goes to corresponding state to deal with the change.
    VI has been attached please give any your comments, suggestions, and advices. THANK YOU.
    Guoguang Qian
    Attachments:
    PC-QueuedStateMachine-IETS.zip ‏1417 KB

    I have not looked at your code from a functionality point of view (plus I did not run it).
    However, I must say that it is among the cleanest, well organized code that I have read on this forum.  Great job.
    Your code is readable, scalable and maintainable.  3 important attributes.
    You are relatively new on this forum.  How long have you been coding?  Very nice code.
    There is only one minor thing that I might change.  Not important, really...
    Instead of reading the entire cluster, I would simply read the needed values in the states where they are needed.
    If your code grows, you may need that real-estate in the future.
    Nevertheless, it is a minor point.  I still like the way you wrote your code.

  • Running one sub vi in background while the main vi uses it's generated data, producer/consumer?

    Hi,
    I would like to have a subrutine running at the same time as the rest of the main vi. The subrutine will be constantly producing data, and the main rutine should do different tasks depending on which data has generated the subrutine in that instant. I have read about producer/consumer design http://zone.ni.com/devzone/cda/tut/p/id/3023 but I don't know how to implement this with LV 5.1   Somebody know if it's possible, or there is something missing in my old LV version? The name of the sub vi about queues mentioned in the link are different than the one I have, and I don't achieve to connect correctly the ones I have... (that are create queue, destroy queue, insert element queue and remove element queue).
    Or, does anybody know other way to do what i want?
    Please, some help..
    Thanks a lot.

    Hi javivi,
          The queues in 5.1 are capable of supporting the producer-consumer model.  See the queue example under "Execution Control Examples".  It's showing a simple string value being "inserted" and "removed". To insert non-string data-types, use "Flatten to String" before "Insert Queue Element" then "Unflatten from String" after "Remove Queue Element".
    What "different tasks" will you do based on the data?  How is the data being read by the program - are you reading an analog-input?  Is it a "continuous" acquisition? 
    Cheers!
    "Inside every large program is a small program struggling to get out." (attributed to Tony Hoare)

Maybe you are looking for

  • How do I change text in a pdf file

    How do I change text and info on a pdf file?

  • Inventory Management Collection run

    We would like to increase our Inventory Management Collection run to every 5 minutes (currently every hour).  Can anyone forsee a problem with this or have experienced a problem We have an Unserialized V3 update Thanks

  • Simple Roll over help

    Basically I have a picture of myself... with my head looking at 4 different angles from up to down.. I attached a screenshot... I want the whole flash mapped so that when you mouse is in the upper portion the head is looking up then when you scroll d

  • Dual Display view under Windows XP

    Does my Notebook display dual view under Windows XP?

  • Duplicate columns created in Document Libraries

    Hi, We are having issues with duplicate columns being created in document libraries after copying/moving documents between libraries (SharePoint 2013): Unable to find any users with similar issues on forum Thanks in advance K