Project Server 2013 - Cannot Create Site

When creating and publishing a project, Project Server is set up to create a site URL as part of the process. Since the middle part of this week 12/16/14 this functionality
stopped working and we need it to be working.
Here are the error messages and logs pulled from Project Server and SharePoint Central Admin
Project Server Manage Queue Jobs
Queue:?GeneralQueueJobFailed (26000) - CreateWssSite.CreateWssSiteMessage. Details: id='26000' name='GeneralQueueJobFailed' uid='5461af96-1787-e411-80e9-001dd8b71f51' JobUID='aa2d518a-1787-e411-80e9-001dd8b71f51'
ComputerName='bbe43e90-a923-40ac-8ca7-e8953ab95807' GroupType='CreateWssSite' MessageType='CreateWssSiteMessage' MessageId='1' Stage='' CorrelationUID='9722d79c-33d8-a082-9580-749b949e39eb'. For more details, check the ULS logs on machine bbe43e90-a923-40ac-8ca7-e8953ab95807
for entries with JobUID aa2d518a-1787-e411-80e9-001dd8b71f51.
ULS Logs from SharePoint
Standard Information:PSI Entry Point: <unknown>
Project User: <unknown>
Correlation Id: <unknown>
PWA Site URL:
SA Name: <unknown>
PSError: <unknown>
A queue job has failed. This is a general error logged by the Project Server Queue everytime a job fails - for effective troubleshooting use this error message with other more
specific error messages (if any), the Operations guide (which documents more details about queued jobs) and the trace log (which could provide more detailed context). More information about the failed job follows. GUID of the failed job: aa2d518a-1787-e411-80e9-001dd8b71f51.
Name of the computer that processed this job: bbe43e90-a923-40ac-8ca7-e8953ab95807 (to debug further, you need to look at the trace log from this computer). Failed job type: CreateWssSite. Failed sub-job type: CreateWssSiteMessage. Failed sub-job ID: 1. Stage
where sub-job failed:  (this is useful when one sub-job has more than one logical processing stages).
Any assistance you can provide at this point will be key as our services are impacted with this error.

Hi Mike. Have you changed / modified the project site template recently? If you set the EPT to use the default project site template does it work? Paul
Paul Mather | Twitter |
http://pwmather.wordpress.com | CPS |
MVP | Downloads

Similar Messages

  • Project Server 2013 - Cannot see project schedule in PWA

    Project Server 2013 and Project Pro 2013
    I have admin authority but for some of the projects loaded to the server, and published, i cannot see the Schedule option in the left frame. At least on project has this option available but several others do not. For the projects where I can't see the schedules:
    - Some of these projects were created with imported MPP files from Project 2010, and imported using the wizard,
    - Some were created with imported XML files from Project 2010, and imported using the wizard
    - Some were created with Project Pro 2013 and saved, published to the P13 server.
    Are there some obvious things that I should check as a new admin to this version of Project Server? I'm stumped.
    For all of the above projects (with the issue or not) I can succesfully see everything in Project Professional 2013, and everything seems to function normally in the publish process.

    Hi,
    the first thing to check would be the EPT (Enterprise Project Type) of those projects. Go to server settings, Enterprise Project Types, select the appropriate project type and ensure that the Schedule page is on the left side of the section "New Project
    Page/Project Detail Pages".
    Hope this helps,
    Guillaume Rouyre, MBA, MVP, MCP |

  • Project Server 2013, cannot open project plan in pwa

    I have a clean installation of Project Server 2013 and am able to save project plans, send assignments and receive task updates.
    The one error so far i'm running into is when I try to open any project plan from PWA - I get the following error:
    "we couldn't find the project detail page for this project. see the system administrator."
    Can someone assist in resolving this issue?
    Thank you,
    Damon Curtin | New Signature

    Damon,
    Navigate to Project Web App>>PWA Settings
    Select Enterprise Project types option from "Workflow and Project Details Pages" section
    Validate "available project details page section" by default schedule and project details should be selected in right hand side column, if it is not then add these two pages and click save.
    Hrishi Deshpande – Senior Consultant DeltaBahn
    Blog | < |
    LinkedIn
    Please click Mark As Answer; if a post solves your problem or Vote As Helpful if a post has been useful to you.This can be beneficial to other community members reading the thread.

  • How do I create a project site after I publish a project in Project Server 2013?

    How do I create a project site after I publish a project from project pro 2013 in Project Server 2013? I'm trying to look for an option in the ribbon but haven't found any. 
    Thanks
    James T.F

    Hi James,
    See in the article the procedure for site provisionning settings.
    Note that the project site is created based on the template associated to the chosen project type (EPT) when the user first publishes his project. Be aware that if you allow the user to choose weither or not he'll create a sharepoint site when publishing
    his project, he will be prompted in Project Pro with a dialog box giving the choice to create or not the site.
    Hope this helps,
    Guillaume Rouyre, MBA, MCP, MCTS |

  • Error when create a project in newly Enabled features for Project Web App site collection in Project Server 2013

    I Enable the Project Web App site collection features in Project Server 2013 based on
    http://technet.microsoft.com/en-us/library/jj200305.aspx
    when i try to create a project i get error "GeneralUnhandledException"
    Yasser

    Also, after you provisioned PWA, are you able to get to the server settings? Did you do any configurations with PWA or using the defaults?
    Are you trying to add the project using the FarmAdmin account or did you add yourself as a resource with project manager role?
    Cheers!
    Michael Wharton, MVP, MBA, PMP, MCT, MCTS, MCSD, MCSE+I, MCDBA
    Website http://www.WhartonComputer.com
    Blog http://MyProjectExpert.com contains my field notes and SQL queries

  • Getting Project Site Provisioning Pop-up even after Operational Policies set as Do not create a sites in project server 2013.

    In Project server 2013, users are getting Project Site Provisioning Pop-up even after Operational Policies set as Do
    not create a sites. 
    We can use “Deny” Global Permission, “Manage SharePoint Foundation”, which controls Project site creation/ delete
    as temporary workaround however want to know is this know defect in Project server 2013? 
    Any suggestion would be highly appreciated.
    Thank you

    Hi Raushan,
    I can reproduce the same behaviour in my environment. It pops-up the dialog box when Project Site Provisioning settings set to 'Do Not Create' in the Central admin for the Project Web App.
    As you mentioned already you can control it via permissions as an work-around.
    Alternatively, you can also ask users to select the check box 'Don't show this again for this project'
    Cheers, Badal

  • Project Server 2013 - User cannot create or see his timesheet

    Hi everyone,
    One of my project server user has a little problem with his timesheet.
    When he try to create a timesheet, he has an error message :
    "Sorry ... We can not create the timesheet, because we have encounter a problem with Project Web App or with the data validations,
    especially resources who are users or work resources invalid. Please check
    your environment and try again."
    Or with timesheet which was create before encounter this error, he has this message :
    "Failed while loading the view. Press OK to reload this view with default parameters. Press Cancel to sélect an other view."
    I'd try to check every project where he is as a resource but I didn't found something wrong.
    Maybe it's because one of the custom field is required but other user have no problem to create and view their own timesheet.
    If you have any idea to help me.
    Thanks,
    Patmol

    Please be sure about the permission required for users. If your users are having permission then Check URl which is talking about your issue which is common in PWA 2013
    http://sharing-the-experience.blogspot.in/2013/10/project-server-2013-timesheetaspx-view.html
    http://blogs.technet.com/b/projectsupport/archive/2013/12/11/project-server-2013-error-loading-views-if-the-default-view-is-missing.aspx
    http://carldalton.tumblr.com/
    Hot fix is talking about issue and having Resolution http://support.microsoft.com/kb/2760261/pt
    Cause of the issue
    Run the Sql
    Profiler 
    The timesheet contained two tasks were the value of ASSN_ACT_WORK was NULL instead of 0.00000.
    This caused the System.InvalidCastException in the ULS log and the user error the view failed to load. 
    Remove this kind of entry then you will not face the issue 
    kirtesh

  • Error while creating a Timesheet - Project Server 2013

    Hi everyone,
    One of user of PWA encounters an issue when he tries to create a timesheet. This error only occurs with a timesheet of
    a specific period, he can create all the other timesheet.
    So, when he creates the timesheet, this error occurs : "The timesheet creation failed, because of problems with Project Web App or with data validations"
    After reloaded the list of the timesheets, a link to go to the specific timesheet
    is available but if we click on it, we have this error :
    "View Failue - The view failed to load"
    I think , this error occurs
    because the timesheet is not realy existing even if we have a link to it.
    In the log (full log at the end), I've got this error :
    Exception occured in method 'TimeSheet.CreateTimesheet' System.ArgumentException: These columns don't currently have unique values.
    I've found this link with the same kind of problem :
    http://social.technet.microsoft.com/Forums/projectserver/en-US/b0a92afc-11fc-40ef-9a44-357d953b31f6/unable-to-open-or-create-timesheets-these-columns-dont-currently-have-unique-values?forum=projectserver2010general but I've checked and published all the
    user project but still have the error.
    Have you got any idea where are these columns ? How can I found them without checked every project of PWA ?
    Thanks,
    Patmol
    Full logs, for information :
    [bucketHash:E3B9DED0] Exception occured in method 'TimeSheet.CreateTimesheet' System.ArgumentException: These columns don't currently have unique values. at System.Data.ConstraintCollection.AddUniqueConstraint(UniqueConstraint constraint) at System.Data.ConstraintCollection.Add(Constraint constraint, Boolean addUniqueWhenAddingForeign) at System.Data.DataTable.set_PrimaryKey(DataColumn[] value) at Microsoft.Office.Project.Server.DataAccessLayer.Generated.TimesheetDalBase.ReadCustomFieldsForAssignments(ISet`1 assignmentUids) at Microsoft.Office.Project.Server.BusinessLayer.Timesheet.ImportCustomFields(HashSet`1 assignmentUids) at Microsoft.Office.Project.Server.BusinessLayer.Timesheet.ImportActualsAndCustomFields(IEnumerable`1 assignmentUids, ISet`1 userImported) at Microsoft.Office.Project.Server.BusinessLayer.TimesheetLoaderForGrid.Load() at Microsoft.Office.Project.Server.BusinessLayer.TimeSheet.CreateTimesheet(TimesheetDataSet dsDelta, PreloadType preloadType) at Microsoft.Office.Project.Server.Wcf.Implementation.TimeSheetImpl.<>c__DisplayClass45.<CreateTimesheet>b__44() at Microsoft.Office.Project.Server.Wcf.Implementation.WcfMethodInvocation.InvokeBusinessObjectMethod(String businessObjectName, String methodName, IEnumerable`1 actions) StackTrace: at Microsoft.Office.Project.Server.Native.dll: (sig=6ea170d1-988e-4153-9f1d-0305c0ea0309|2|microsoft.office.project.server.native.pdb, offset=3C1E) at Microsoft.Office.Project.Server.Native.dll: (offset=1255D)
    Watson bucket parameters: Microsoft Project Server 2013, ULSException14, 070f6ea0 "project server", 0f0011db "15.0.4571.0", ea364808 "system.data", 0400766f "4.0.30319.0", 52310bef "thu sep 12 02:33:51 2013", 00000e02 "00000e02", 00000020 "00000020", 44395864 "argumentexception", 00101621 "aeby7"
    Error is: GeneralUnhandledException. Details: General Unhandled Exception in _TimeSheet.CreateTimesheet_ Attributes: System.ArgumentException: These columns don't currently have unique values. at System.Data.ConstraintCollection.AddUniqueConstraint(UniqueConstraint constraint) at System.Data.ConstraintCollection.Add(Constraint constraint, Boolean addUniqueWhenAddingForeign) at System.Data.DataTable.set_PrimaryKey(DataColumn[] value) at Microsoft.Office.Project.Server.DataAccessLayer.Generated.TimesheetDalBase.ReadCustomFieldsForAssignments(ISet`1 assignmentUids) at Microsoft.Office.Project.Server.BusinessLayer.Timesheet.ImportCustomFields(HashSet`1 assignmentUids) at Microsoft.Office.Project.Server.BusinessLayer.Timesheet.ImportActualsAndCustomFields(IEnumerable`1 assignmentUids, ISet`1 userImported) at Microsoft.Office.Project.Server.BusinessLayer.TimesheetLoaderForGrid.Load() at Microsoft.Office.Project.Server.BusinessLayer.TimeSheet.CreateTimesheet(TimesheetDataSet dsDelta, PreloadType preloadType) at Microsoft.Office.Project.Server.Wcf.Implementation.TimeSheetImpl.<>c__DisplayClass45.<CreateTimesheet>b__44() at Microsoft.Office.Project.Server.Wcf.Implementation.WcfMethodInvocation.InvokeBusinessObjectMethod(String businessObjectName, String methodName, IEnumerable`1 actions) . Standard Information: PSI Entry Point: Project User: i:0#.w|wavenet\cev Correlation Id: 9709e41b-9a18-e411-941e-00155d029b05 PWA Site URL: http://intranet.wavenet.lan/PWA SA Name: Project Server Application PSError: GeneralUnhandledException (42), LogLeve...

    Hi Patmol,
    Have you tried to go to the previous or next timesheet and then navigate with the "previous period" or "next period" to the timesheet in question.
    Also have you tried to open it using a delegation session?
    Hope this helps,
    Guillaume Rouyre, MBA, MCP, MCTS |

  • Can new PWA views be created whereby a filter can be set and associate to the view by default? (Project Server 2013 ONLINE)

    My main question is: Can new PWA views be created whereby a filter for that view can be set, and associate to the view by default? (Project Server 2013 ONLINE)? and can I have a filter set to filter on person logged on to...
    In previous versions of Project Server, when CREATING a PWA view, we were able to apply/ define a filter for that view.  Does not seem like it is the case in Project Server 2013 Online.  And if I remember, we could also use the URL Guid_view_id. 
    Please confirm; and / or tell me how-to.
    What I was hoping to do is the following... Given that our standard that we have adopted for reporting time is 'My Timesheets' (fyi, Single Mode Entry=ON), we have some resources who have others who do it on their behalf via 'My Tasks' (ie., accomplished
    by using the 'Assignment Owner' field, accordingly).  Therefore, when entering time on someone else's behalf within 'My Tasks', we like to present the user that is logged in only the tasks that they are are assigned to update on others' behlaf.
    I know that there is another more elegant approach to doing this which may be to use the Delegation feature. But since we are trying to stick to Sharepoint Security mode for now, this is not an option for the time being.
    Any help appreciated would be greatly appreciated.
    \Spiro Theopoulos PMP, MCITP. Montreal, QC (Canada)

    Hi Spiro,
    1- You still can define in Project Online a filter in the view settings, it is located just above the category setting. Here is a screenshot of the summary project center view:
    2- The view GUID is not anymore in the URL, since the URL triggers an action only on the webpart and not on the whole page. I agree this is annoying since it was great to send a URL with a specific view.
    3- Concerning the access to my timesheet versus my task, I'm not sure to get a full understanding but on a general way, it is much more easy to deal with those situation using categories which you cannot do with the SP permission mode.
    Hope this helps,
    Guillaume Rouyre, MBA, MVP, P-Seller |

  • Creating custom Category for Risk & Issue in Project Server 2013

    Dear All,
    How to Change Risk & Issue Category default as per business requirement when selecting them through drop down or radio button?
    I can do only Project wise from project site & then setting changes. But i want to customize it for all projects which are getting published in Project Server 2013. So doing manually every time project wise not making sense & consuming time also.
    Kindly help..

    I have created custom template but not getting as demonstrated in  blog
    post from Prasanna  specially
    end part where Risk, Issue n all content can be seen. In My case only simple 3-4 items can be seen apart from risk, issue etc.
    After that i saved this custom template to my
    one of EPT in Project Server 2013. But unable to customize my Risk & Issue Category options for all projects. However, i have gone through that post & unable to understand as described in 2010 & i am using 2013 version.
    Kindly let me know after saving custom Template
    to EPT how to move further to customize these risk & issue categories globally.!!

  • Project Server 2013 Tasks differ in project site and plan

    I have an Project Server 2013 enterprise plan that I created with an associated project site. The plan has tasks added to the timeline. The project site has a timeline webpart but the problem is the tasks added to the timeline differ.
    Does anyone have any ideas what could be the problem here? I checked the timeline webpart and it's correct.
    Thanks!
    [Images below].
    The following image is taken from the schedule PDP.
    This image taken from the project site depicts what is out of sync.

    Hi Guillaume,
    Yes, I've checked the queue while publishing the project. It's successful without any errors. I don't remember if I checked the ULS logs, but what I suspect is that it will say something along the lines of orphaned tasks in the project site.
    Anyways I've tried a number of things and I think the only 2 options I have are:
    Re-create the project site then sync the plan to it
    Ask MSFT for a script to resolve the orphaned tasks
    For the same of time, I'm going to assess how long it would take to re-create the project site.
    Thanks,
    Roland

  • Project Server 2013 Project Site Permission

    Hi All,
    Q1: We are using project server 2013, most of the time the projects are created by the PMO coordinators and it will be assigned to the project manager. Project coordinator and Project Manager belongs to "Project Manager" group. After assigning
    the project when the project manager tries to access Project Site, he is getting "why you want to access this site". When I checked project site permission only project coordinator name is added to the Owners group. Normally the project owner should
    have the permission to the project site, how to fix it.
    Q2: We have different enterprise project type with different site templates. When the project type is changed from one type to another, is it possible to delete and recreate the respective project sites automatically.
    Thanks in advance, Taj

    Taj,
    Q1) this is a question related to how your security is set up. If you are using Project Server Permission mode, people in Project managers groups, who have edit ability on your project will get added to the Project manager Synchronized group on the project
    site upon publish. You just need to make sure your secueiry ctegories and groups are set up as such.
    Alternatively, you could set the owner of the project to be the project manager once they take ownership.
    Q2) This will be a manual activity. You need to disconnect the site under server settings, then delete site. Then you can create the site, which will pickup the new EPT set project site template automatically.
    Cheers,
    Prasanna Adavi, Project MVP
    Blog:
      Podcast:
       Twitter:   
    LinkedIn:
      

  • Project Server 2013 Project Site Documents

    Hi All,
    We are using project server 2013. The project site (template) document library is configured with the project folders and templates. i.e. when the project is created, the project site will be created with required project document templates. We want to delete
    the project document templates from the projects sites which was created already, how can we achieve this.
    Thanks in advance, Taj

    Taj,
    The simplest way I can think of is to use PowerShell. Be careful with it, though, and test in a test enviroment, so that you do not end up deleting files that you actually want.
    This article should give you a good start: https://habaneroconsulting.com/insights/Delete-SharePoint-Files-With-PowerShell#.VOGMePnF-So
    Cheers,
    Prasanna Adavi, Project MVP
    Blog:
      Podcast:
       Twitter:   
    LinkedIn:
      

  • Project Server 2013 project site navigation

    Hi All,
    We are using project server 2013. We have customized the project site template. We want to display the Project Web App navigation (link) in the top of the project site. While customizing the project site it is showing the Project Web App link at the
    top. Once it is configured in the project enterprise project type and created project the Project Web App link is not appearing. It is showing only the project name.
    Thanks in advance, Taj

    Hi Taj,
    Have you followed procedure below from Prasanna post?
    http://www.prasannaadavi.com/2013/05/project-site-navigation-in-project.html
    Was the link correctly working in the project site before saving it as a template? Try creating a project site directly from the template (without creating a project first). Also be sure that you associated the correct site template to the EPT you chosen
    in PWA project center for creating the new project.
    Hope this helps,
    Guillaume Rouyre, MBA, MCP, MCTS |

  • Need to create a TASKS page with a filter default in PWA Project Server 2013 (Online)

    Never done this so, I am wondering How to go about or what I would need to create a simple PWA page like "Tasks" in Project Server 2013 online where it default to a filter that is set to not equal to the user that is logged on?
    \Spiro Theopoulos PMP, MCITP. Montreal, QC (Canada)

    Hi Spiro,
    The "my tasks" page or "my timesheet" are automatically filtered on the user currently connected. Unless you are using workarounds such as status manager or delegation, I see no way to bypass this.
    Hope this helps,
    Guillaume Rouyre, MBA, MVP, P-Seller |

Maybe you are looking for