Project Server On-line 2013 Web error

Hello, Everybody
My environment
is Project Server 2013 On-line but when i tried to access to PWA  i receive the following error:
Error de elemento web: Ocurrió
un error. Id. de correlación: f26ecd9c-c0f2-1000-9e8b-56e221baacb5.
Help me please
marylu

Hello. Do all users get this error? Tried a different machine and or browser? Paul
Paul Mather | Twitter |
http://pwmather.wordpress.com | CPS |
MVP

Similar Messages

  • How to Migrate MS Project Server 2007 to 2013

    Hi
    Can any one share some reference for migrating Project Server 2007 to 2013.
    As in general process--
    We can take the backup and and restore it in 2013 environment.
    How to migrate Portfolio Server?
    After restroring any steps need to be followed.
    Please guide.
    Thanks
    Geeth If you feel that the answer which i gave you is Helpful please select it as Answer/helpful.

    Hello,
    For Portfolio Server 2007 options, review this guide:
    http://www.microsoft.com/en-us/download/details.aspx?id=20815
    Also see:
    http://blogs.technet.com/b/projectadministration/archive/2010/07/21/anouncing-project-portfolio-server-2007-migration-documentation-to-project-server-2010-just-released.aspx
    Paul
    Paul Mather | Twitter |
    http://pwmather.wordpress.com | CPS

  • What Project Server 2010 and 2013 make possible in terms of timesheeting, "freezing" timesheets and expenses.

    We have recently gone live on a Timesheeting system based on Project Server 2007.
    I now want to know how the system could be improved using 2010 or 2013.
    But first you would need to know our requirements and what we did in 2007 ...
    We needed the GUI of My Timesheets and the Admin tasks but approvals based on what project/task it was. Ie PM approval not line management approval.
    We managed it by entering timesheets in My Timesheets, importing to My Tasks and then regularly picking up published Task Updates in the Table EPMAssignmentByDay and capturing them in an added table in the Reporting database. We had a few key requirements
    which required some customisation:
    Need to capture the timestamp of when approved. to nearest hour. plus approver ID (ie status manager) and the cost centre at that time of the resource (they can move sometimes)
    Need to be able to freeze approved records - so that after that point they can't be changed. And financial reports can run and know the data won't change.
    2 - is a headache for us. There is no mechanism to stop a user from trying to update frozen records. We currently have to just ignore the updates
    We also wanted expenses - but that wasn't possible in 2007.
    The new "Single Entry" mode looks like it will make life easier for the users.
    But:
    Is there any concept of timestamping the approvals?
    Is there any concept of freezing the approved data?
    The new Timesheet user-defined fields. Could these be used to add an expense amount and comment?
    I now know my way around the 2007 Reporting Database (at least parts of it) - but haven't found documentation to tell me what changed at the level need to answer the questions above.
    Thank you
    MikeCro
    MikeCro

    One of my colleagues pointed me to the MSFT paper "Managing timesheets in Microsoft Office Project Server 2007"
    It tells me that there is a field called "Processed" in the timesheet tables in 2007.
    It also says "This block is designed to indicate when a timesheet has been transferred to a third-party system. 
    Customers may also use this field to block the timesheet from being recalled." - which feels like MSFT are trying to give the hooks I need. This could enable me to close off changes - at least at timesheet level if not timesheet line level.
    But which field is it in which database table?
    I also notice that there is a tantalising comment for one value of the enumeration TimesheetEnum.Status in EPM 2013:
    PendingSubmit: Value=5. Pending submission; used when one or more timesheet lines are pending approval after a timesheet is submitted and project manager coordination is required.
    This sounds very like it would support what we want: each of the lines in a timesheet week to be approved by the different approvers and then lock the timesheet.  (Even better would be to lock a row after PM has approved and a weekly processing
    day reached)
    Can anyone point me to this level of detail of what is in project Server 2013. or is this in 2010 as well.
    MikeCro
    MikeCro

  • Upgrading from Project Server 2010 to 2013 ConvertTo-SPProjectDatabase gives error (Convertto-SPProjectDatabase : Action 15.0.38.0 of Microsoft.Office.Project.Server.Upgrade.PublishedDatabaseSequence)

    Getting the error on subject line when I try to upgrade from Project 2010 to 2013

    Hi,
    Do you get and error when the command is executed or when you try to start the execution (the command is not valid)?
    If you get the error when you try to start the execution, I would suggest re-typing the command and make sure all parameters are valid.
    Please give us the error details if you get the error when the command is running
    Paul

  • Project Server 2013 migration workspace error

    Project Server 2013 migration workspace error
    Hello all,
    I have just completed my Project Server 2010 to 2013 migration. All look OK until I tried using Project Professional 2013 and opening a project with about 25
    Users (Enterprise Resource) . Opening took about 7 min. I tried creating a new project with 5 users and still took longer then is should. 
    I decided to run the below command and I received a lot of errors about missing workspace.  Please help if anyone can.
    Thank you in advance !!!
    Test-SPProjectWebInstance -Identity http://XXXXXXXX.XXXXXX | Format-Table -Wrap -AutoSize | Out-File -FilePath c:\
    Rule                                                                        
                     TimeStamp             Message                          
    Microsoft.Office.Project.Server.HealthRules.ProjectBICenterExistenceHealthRule                4/16/2014 12:05:57 AM                              
                                              The following ProjectBICenters   
                                              have missing lists:              
                                              (/projectserver/ProjectBICenter, 
                                              Reports).                        
    Microsoft.Office.Project.Server.HealthRules.ProjectWorkspacesExistenceHealthRule              4/16/2014 12:05:58 AM The following projects are       
                                              missing the workspace webs: 'cf8f
                                              0345-c4b5-e311-a4d0-0019b93bec52'
                                              , '52babaa6-c4b5-e311-a4d0-0019b9
                                              3bec52', '37ff2ac5-37bc-e311-b0a9
                                              -0019b93bec52', '17fe20c2-38bc-e3
                                              11-b0a9-0019b93bec52', 'b7faad6a-
                                              39bc-e311-b0a9-0019b93bec52', 'c9
                                              a70e95-a3b3-e311-b36f-0019b93bec5
                                              2', 'fdf3c3f9-86ba-e311-b3d2-0019
                                              b93bec52', 'ee95175e-f4bc-43f6-a9
                                              c9-02837b5791bc', '5e2cbc54-4114-
                                              4f24-af05-03e024c85046', 'bfd9e49
                                              5-2a42-405c-9035-04e51f4afb2b', '
                                              e381d24d-e82d-452b-b1ae-04f74e215
                                              fd8', 'b85dc99a-0989-4fe1-af0a-05
                                              c6b9448991', 'f2e1c579-2493-4ffd-
                                              99a0-072b7f5f527f'

    All,
    Bulk update and post up gradation tasks was completed at time of migration.
    I did notice that when opening Project Professional 2013 and unselecting
    Load Resource Assignments, everything opens and runs as it should. Not sure why ? So I think for now, I'll run Project Professional 2013 without Load Resource Assignments until I find a fix.
    As for (The following projects are missing the workspace webs) error, still getting them.
    Thanks all for the Quick Reply's.
    JBAE

  • Error creating Project Server 2013 Server Side Event Handlers

    Hi,
    I have created a WCF service and deployed it successfully.  Now when trying to add a new event receiver for Project CheckIn event, nothing happens.  Checking the service using Services panel, it shows Microsoft Project Server Events Service 2013
    is started.  I check the ULS logs and see exception:
    System.Data.SqlClient.SqlException (0x80131904): Could not find stored procedure 'pub.MSP_ADMIN_SetEventReceivers15RTM'
    I have service pack 1 installed for Project Server and SharePoint, version 15.0.4571.1502.  Any ideas?  I see there is a stored procedure without '15RTM' suffixed in PWA database.  I read another post on the forum relating to this same issue
    but didn't want to create each additional item in the DB (table, data type, stored procedure, etc).  Am I missing something?  Looking for suggestions here.  Your help is always appreciated.
    Thanks,
    kashif

    Hi Gokulraj,
    What permission mode are you using in project server 2013? Is it "project permissions mode" or "SharePoint permissions mode"?
    If you are using "project permissions mode", then go to Server Settings -> Manage users and click on the user with "team member" permissions to edit.
    In the next page, expand "Global Permissions" and "View Approval" permission.
    It could be the issue with the categories and category level permissions.
    Happy troubleshooting...
    Vikram Daruru - MSFT

  • Problems installing Project Server 2013 SP1

    Hi,
    I have an issue installing Project Server SP1 (KB2880553). The history of this installation is as follows below:
    I have one App Server and one Web Server (test environment)
    On February I installed the mistaken SharePoint 2013 SP1, Project Server SP1 and Language Pack SP1 in both servers, followed by SharePoint Config Wizard. No problem here, other than the mistaken SP1's
    The current week I've installed SharePoint SP1 (KB2880552) in both servers, followed by SharePoint Config Wizard. No problem here.
    Then I installed Project Server SP1 (KB2880553) in both servers, it got installed in both servers apparently, but when I run the SharePoint Config Wizard in the APP server I get the error below and I can't continue:
    If I try to install Project Server SP1 in the Web Server it tells me that the product is alteady installed there, if I try to install the Language Pack SP1 KB2880554, it tells me that there is nothing to be installed  in that Web server.
    If I check the Patch Status in Central Admin, this is what I get regarding the Web server, the APP server is apparently ok:
    So the problem is that I can do nothing, as it doesn't allow me to install anything anywhere.
    Please, do you know what to do in this case?
    Thank you for your help and regards,
    José Espases

    Hi,
    thank you for your answer.
    Maicco, I've already tried to follow the links but as I said initially there is nothing that I can install, as you can see in the second picture that I sent before, the KB2880553 is installed partially (last line) but missing/required in other lines, so
    when I try to install it again it keeps saying that it has been already installed, but when I execute the Config Wizard it says that it is missing and required.
    The Uninstallation/installation is what I try to avoid.
    Raymundo, regarding the post http://www.maadarani.com/Blog/Lists/Posts/Post.aspx?ID=12&mobile=0 it
    doesn't work, probably something is missing in the link, please, can you send it again?
    Thank you and regards,
    José Espases

  • Project Server 2013 Upgrade

    Hi everyone.
    I'm having trouble upgrading my databases from project server 2010 to 2013.
    I followed all steps, but when i get to the
    Convertto-SPProjectDatabase
    part, i always get this error:
    ConvertTo-SPProjectDatabase : A parameter cannot be found that matches parameter name 'Lcid'.
    At line:1 char:391
    + ... eDbname SynPDE -Lcid 1033
    +                    ~~~~~
        + CategoryInfo          : InvalidArgument: (:) [ConvertTo-SPProjectDatabase], ParameterBindingException
        + FullyQualifiedErrorId : NamedParameterNotFound,Microsoft.Office.Project.Server.Cmdlet.PSCmdletConvertToProjectServiceDatabase
    What am i doing wrong, it always complaints about the LCID parameter.
    This is my script:
    Convertto-SPProjectDatabase-WebApplicationhttp://mywebapp-Dbserver mysqlserver-ArchiveDbnamePWA_Archive_DF0B957B_A7F1_4EFC_BCFB_12E0B22DA329-DraftDbnamePWA_Draft_DF0B957B_A7F1_4EFC_BCFB_12E0B22DA329-PublishedDbnamePWA_Published_DF0B957B_A7F1_4EFC_BCFB_12E0B22DA329-ReportingDbnamePWA_Reporting_DF0B957B_A7F1_4EFC_BCFB_12E0B22DA329-ProjectServiceDbnameSynPDE-Lcid1033
     Can someone help? is this a bug with the script?
    Thank you.

    Executing command without LCID parameter obtain an error in the upgrading of Reporting database. Looking for in Sharepoint Logs:
    The upgrading Published Database is OK
    "Finished upgrading ProjectDatabase Name=MIGRA_ProjectServer_Published. 466d2d71-332e-4930-bbf3-d65b7dd1b28a"
    The upgrading Reporting Database is ERROR
    "ERROR Action 15.0.10.0 of Microsoft.Office.Project.Server.Upgrade.ReportingDatabaseSequence failed. 466d2d71-332e-4930-bbf3-d65b7dd1b28a
    ERROR Exception:The conversion from data typevarchar
    to datetime produced a value out of range. 466d2d71-332e-4930-bbf3-d65b7dd1b28a
    ERROR    en System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction)     en System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj,
    Boolean callerHasConnectionLock, Boolean asyncClose)     en System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj,
    Boolean& dataReady)     en System.Data.SqlClient.SqlCommand.RunExecuteNonQueryTds(String methodName, Boolean async, Int32 timeout)     en System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(TaskCompletionSource`1
    completion, String methodName, Boolean sendToPipe, Int32 timeout, Boolean asyncWrite)     en System.Data.SqlClient.SqlCommand.ExecuteNonQuery()     en Microsoft.Office.Project.Server.Data.SqlSession.ExecuteNonQuery(SqlCommand
    command)     en Microsoft.Office.Project.Server.Upgrade.ProjectDatabaseUpgrader.ExecuteUpgraderSqlScript(String sql)     en Microsoft.SharePoint.Upgrade.SPActionSequence.Upgrade() 466d2d71-332e-4930-bbf3-d65b7dd1b28a"

  • Project Server 2013: Empty issues, questions and documents list in the PWA task details pane

    Project Server 2012, SharePoint 2013
    I have a task with a few attached issues, risks and documents. And I see links to that in the PWA project plan (as icons).
    But when resource open his PWA task pane attachment lists (issues, risks and documents) are empty.
    Why? How to add documents in that lists?

    Hi,
    I have a solution that might work for you, please follow steps below:
    1) Go to your project schedule, make a small modification to any task on schedule and 'Publish' the project.
    2) While your project is being published and saved, open another window 
    Server Settings -> Manage Queue Jobs
    3) Here you can view the progress of your current Project Publishing update, check if all goes smooth and your project is published successfully without indicating any errors of issues like :
    Reporting transfer WSS links failed ( to view any error look at the last column of table on Manage Queue Job page)
    4) Also in your Project window see if the project is published and not saved as Draft.
    Basically this will give you a fair idea of your project being published or not, if not that there is some problem with your Lists ( Risks, Issues and Documents).
    Regards

  • Project Server 2013 Anonymous Access (SP or PS modes)

    Greetings,
    This has become quite painful.  I have two tickets opened with M$ and I've never witnessed that with which I am witnessing.
    Simple question, how to enable Project Server 2013 Anonymous Access...I've been at it for over a week, I've tried in both SP perms mode and PS perms mode.  And I've built a bone stock SP/PS server to determine if my farm's jacked or not.  I get
    the exact same behavior...prompt for creds.  M$ told me today that anon has never ever been something offered in SP or PS today or at any point in the past.  A simple gotomeeting sent that group reeling out off into outer space.  I'm glad I
    could help them on their technical journey, but damn't if I don't feel used for spending $1000 on two tickets.
    Tried everything I could possibly think of...Please help, before I eat a bullet.

    When you enable anonymous access to a Web site, you allow anonymous users (and authenticated users who have not been granted access to the site) to browse the entire Web site, including any list, library, folder within a list or library, list item, or document
    that inherits its permissions from the Web site
    I think you are referring to PWA/_layouts/15/user.aspx if I understood your query correctly.
    As you could read, its referring to SharePoint list and libraries and not Project Webpart data.
    Anonymous Access: Specify what parts of your Web site (if any) anonymous users can access. If you select Entire Web site, anonymous users will be able to view all pages in your Web site and view all lists and items which inherit permissions
    from the Web site. If you select Lists and libraries, anonymous users will be able to view and change items only for those lists and libraries that have enabled permissions for anonymous users. 
    So this anonymous doesn't mean users can access, PWA pages like Projects.aspx with anonymous account. If this happens all anonymous users would see all projects...
    Project PWA site, has pages like tasks.aspx, projects.aspx, Timesheets.aspx, etc. Users who access Project Server 2010 through the Web interface (Microsoft Project Web App) use these pages that are composed of Web Parts, which are modular elements that present
    information on SharePoint pages. Now, to get users based data, this checks for user role, permission and data is rendered.
    http://technet.microsoft.com/en-us/library/gg314584(v=office.14).aspx
    I am curious to know if you would like all users who have not been granted access to the site also access your projects? What is the objective or business requirement you are trying to solve here.
    Shazeb Khan

  • Error TF282808 'TaskNotFound' error after admin restore on Project Server

    We have an integration between TFS 2012 and Project Server 2010 (SP2, with CU).
    After an administrative restore of a project on Project server, the workitems that were added to TFS after the point of the backup now fail to synchronise with the following error in the workitem history:
    TF282808: An error occurred when sending status update to Project Server during
    synchronization. Returned error code: "TaskNotFound". Contact your Project
    Server administrator and report the error code.
    Workitems that were present before the time of backup sync normally. Workitems that were added after the restore also function normally. It appears as if the sync does not understand that an item from TFS that synced in the past can be new on Project Server
    (due to the restore).
    I have already tried deleting the webcache on the SharePoint server (C:\ProgramData\Microsoft\Team Foundation\Web Access\Cache_v11.0.xxx) followed by an IISReset.

    Hi guys, I am getting this too. 
    I have this for several PBI in one team site, and this came out of nowhere. 
    TF282808: An error occurred when sending status update to Project Server during synchronization. Returned error code: "TaskNotFound". Contact your Project Server administrator and report the error code.
    I also get this when I try to publish the project Ms Project PRO
    TF80070: Team Foundation encountered an error while performing the operation. It is recommended that you save your work and restart the application.
    This is the tfs_msproject log
    Exception:  {
    Exception Message: Värde får inte vara null.
    Parameternamn: key (type ArgumentNullException)
    Exception Stack Trace:    vid System.Collections.Generic.Dictionary`2.FindEntry(TKey key)
       vid Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectAllowedValues.GetMappingOfValuesToIndex(PjCustomField pjCustomField)
       vid Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectServerIntegration.WorkItemTypeFieldManager.SetupWorkItemTypeField(Project project)
       vid Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectServerIntegration.PrePublishValidationManager.Validate(Project project)
       vid Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectServerIntegration.ProjectServerIntegrationAddIn.OnProjectBeforePublish(Project project, Boolean& cancel)
    WINPROJ.EXE Error: 0 : [Error, PID 3844, TID 8296, 2014/02/28 11:56:43.233, 8009313 ms, General] TF80070: Team Foundation encountered an error while performing the operation. It is recommended that you save your work and restart the application.
    WINPROJ.EXE Error: 0 : [Error, PID 3844, TID 8296, 2014/02/28 11:56:46.016, 8012096 ms, General] UIHost.ShowMessageBox: result=OK caption='Microsoft Office Project' text='TF80070: Team Foundation encountered an error while performing the operation. It is recommended
    that you save your work and restart the application.'
    WINPROJ.EXE Information: 0 : [Info, PID 3844, TID 8296, 2014/02/28 11:56:46.073, 8012153 ms, General] Whole publish-to-tfs tree validation!

  • Error Message " An error occured while running the detection " Sharepoint 2010 & Project Server 2010

    i am trying to Update the Service Pack of sharepoint & Project
    Server (SP2) . i got an error while running the Package " An error occured while running the detection " ... I searched a bit and ran ROISCAN.vbs script which is by provided by MS to identify any issues ... i Found that few MSI files of sharepoint
    are missing from WINDOWS Installer folder.... My Question is Should i repair the Sharepoint or any tool that i can use to get the MSI ?

    There is a MS internal tool for fixing this issue but for this may be you need to contact MS, refer to below links:
    Utility Name: OPUtil.vbs
    http://social.technet.microsoft.com/Forums/en-US/a7919b10-e4fe-4911-9016-bb6b81cf4194/sharepoint-patch-update-issue
    http://blogs.technet.com/b/paulpaa/archive/2010/03/26/sharepoint-2007-hotfix-failed-with-an-error-the-detection-failed-this-can-be-due-to-a-corrupted-installation.aspx
    Please ensure that you mark a question as Answered once you receive a satisfactory response.

  • Trying to add Admin account in project server 2010 via powershell

    Dear All
    Unfortunately some one removed admin account from PWA 2010 so i have tried to add admin account via powershell command
    New-SPProjectSiteAdministrator -AdminAccount "dir\santosh" -Url "https://myserver/PWA"
    New-SPProjectSiteAdministrator : <nativehr>0x80070005</nativehr><nativestack></nativestack> At line:1 char:31 + New-SPProjectSiteAdministrator <<<<  -AdminAccount "dir\santosh"
    -Url "https://myserver/PWA"     + CategoryInfo          : InvalidData: (Microsoft.Offic...ewAdministrator:PSCmdletNewAdministrator) [New-SPProjectSiteAdministrator], Unaut   
    horizedAccessException     + FullyQualifiedErrorId : Microsoft.Office.Project.Server.Cmdlet.PSCmdletNewAdministrator
    Getting above error
    Help me
    Regards
    Santhu

    Hello,
    Can't you log in with an account that is already in the Administrators group then add the new account? I think you will need to run the command with a user account that already has admin access to PWA - I don't currently have an environment to test this
    on.
    Paul
    Paul Mather | Twitter |
    http://pwmather.wordpress.com | CPS

  • Workflow Start "Failed But Not Blocking Correlation" - Project Server workflow for Demand Management

    Hi,
    I'm trying to "Create a Project Server workflow for Demand Management" with project server 2013 just like is explained
    here.
    But when I try to create a new project the implemented workflow failed to start with the follow state message in the job queue: Failed But Not Blocking Correlation.
    The detailed error display the follow message:
    Exception Starting Workflow: The scope _/SharePoint/default/139e833f-7a85-4ccf-b7a2-b3fea9ce50b9/6799b7e5-e519-40f4-9371-0b3bc3d5c208_ has no workflows under it. HTTP headers received from the server - ActivityId: 52fef415-409b-4545-a9f6-ed75519b425c.
    NodeId: My-Computer-Name. Scope: /SharePoint/default/139e833f-7a85-4ccf-b7a2-b3fea9ce50b9/6799b7e5-e519-40f4-9371-0b3bc3d5c208. Client ActivityId : 9ded4d9c-7733-7004-2661-c8977270af98.. Trace:    at Microsoft.Workflow.Client.ClientHelpers.SendRequest[T](HttpWebRequest
    request, T content)   at Microsoft.Workflow.Client.WorkflowManager.StartInternal(String workflowName, WorkflowStartParameters startParameters)   at Microsoft.SharePoint.WorkflowServices.FabricWorkflowManagementClient.StartInstance(String
    serviceGroupName, String workflowName, String monitoringParam, String activationKey, IDictionary`2 payload)   at Microsoft.SharePoint.WorkflowServices.FabricWorkflowInstanceProvider.StartWorkflow(WorkflowSubscription subscription, IDictionary`2 payload)  
    at Microsoft.Office.Project.Server.BusinessLayer.Workflow.StartWorkflow(Guid projectGuid, Guid enterpriseProjectTypeUid, Boolean isNewProject, Guid previousEntepriseProjectTypeUid, Boolean skipStage, Guid stageToSkipTo):
    WorkflowExceptionStartingWorkflow (35115). Details: id='35115' name='WorkflowExceptionStartingWorkflow' uid='e3bbb06b-1d38-e311-940a-001cc094718e'.
    Error:
    WorkflowCannotStartWorkflow (35100). Details: id='35100' name='WorkflowCannotStartWorkflow' uid='e4bbb06b-1d38-e311-940a-001cc094718e'.
    Queue:
    GeneralQueueJobFailed (26000) - WorkflowStartWorkflow.WorkflowStartWorkflowMessage. Details: id='26000' name='GeneralQueueJobFailed' uid='e5bbb06b-1d38-e311-940a-001cc094718e' JobUID='68ee1040-1d38-e311-940a-001cc094718e'
    ComputerName='90f7432c-fbc8-4ebd-86f3-0236ce62661c' GroupType='WorkflowStartWorkflow' MessageType='WorkflowStartWorkflowMessage' MessageId='1' Stage='' CorrelationUID='9ded4d9c-7733-7004-2661-c8977270af98'. For more details, check the ULS logs on machine
    90f7432c-fbc8-4ebd-86f3-0236ce62661c for entries with JobUID
    68ee1040-1d38-e311-940a-001cc094718e.
    with this detailed entries in the log file
    10/18/2013 13:47:57.38  Microsoft.Office.Project.Server (0x0948) 0x14F0 Project Server                 Queue                        
     ad3fy Critical Standard Information:PSI Entry Point: <unknown>  Project User: <unknown>  Correlation Id: <unknown>  PWA Site URL:   SA Name: <unknown>  PSError: <unknown> A queue job
    has failed. This is a general error logged by the Project Server Queue everytime a job fails - for effective troubleshooting use this error message with other more specific error messages (if any), the Operations guide (which documents more details about queued
    jobs) and the trace log (which could provide more detailed context). More information about the failed job follows. GUID of the failed job: 68ee1040-1d38-e311-940a-001cc094718e. Name of the computer that processed this job: 90f7432c-fbc8-4ebd-86f3-0236ce62661c
    (to debug further, you need to look at the trace log from this computer). Failed job type: WorkflowStartWorkf... 9ded4d9c-7733-7004-2661-c8977270af98
    10/18/2013 13:47:57.38* Microsoft.Office.Project.Server (0x0948) 0x14F0 Project Server                 Queue                        
     ad3fy Critical ...low. Failed sub-job type: WorkflowStartWorkflowMessage. Failed sub-job ID: 1. Stage where sub-job failed:  (this is useful when one sub-job has more than one logical processing stages). 9ded4d9c-7733-7004-2661-c8977270af98
    10/18/2013 13:47:57.38  Microsoft.Office.Project.Server (0x0948) 0x14F0 Project Server                 Queue Jobs                   
     ad3fy Medium   Error is: GeneralQueueJobFailed. Details: Queue Attributes:  68ee1040-1d38-e311-940a-001cc094718e  90f7432c-fbc8-4ebd-86f3-0236ce62661c  WorkflowStartWorkflow  WorkflowStartWorkflowMessage  1   
    9ded4d9c-7733-7004-2661-c8977270af98  . Standard Information: , LogLevelManager Warning-ulsID:0x000DD158 has no entities explicitly specified. 9ded4d9c-7733-7004-2661-c8977270af98
    Any idea?
    Thanks in advance,
    Alexander.

    Hi Alexander,I have seen that error when the workflow manager has not been registered correctly with the PowerShell command - that should be in the docs referenced - or
    http://technet.microsoft.com/en-us/library/jj663115.aspx.  Let me know if that doesn't appear to be the issue here and I can dig deeper.  Best regards,  Brian
    Blog |
    Facebook | Twitter | Posting is provided "AS IS" with no warranties, and confers no rights.
    Project Server TechCenter |
    Project Developer Center |
    Project Server Help | Project Product Page

  • Project was not able to connect to project server

    We have a user running Project 2007 who gets the following error when trying to open Project:
    "Project was not able to connect to project server because of the following error: the credentials you used to login may not be correct."
    The users PC had been disjoined and rejoined to our domain to fix a separate issue and since doing that she is getting this error when trying to open project. We have confirmed her network credentials are good and she is able to access other network resources
    with no problem.
    Thanks
    Hank Vare

    Sorry for the abbreviation used, by PWA i mean Project Web Access, which is the other interface for Project server essentially the IE where you open the Project Web App
    I asked this based on the assumption given the error "Project was not able to connect to project server "
    Hence assuming you are trying to connect to project server and you have a project server environment, if that's not the case and you are working standalone then navigate to Start >> All programs >> Microsoft office >> Microsoft Office tools
    >> Microsoft Project Server Accounts >> Select the computer and Set it as default
    Thanks | epmXperts | http://epmxperts.wordpress.com

Maybe you are looking for

  • SQL Server 2012 not auto-shrinking logfile

    We recently deployed SQL Server 2012 Standard on a Server 2008 R2 SP1 machine and, for the most part, everything behaves the same as SQL 2008 R2 (no surprise there). However, one issue I've been experiencing is that the transaction logs will not auto

  • When I export an email as a PDF it only displays the sender details not the content

    I normally export any email I wish to save as a PDF, for some reason a tax receipt I've just received, when exported as PDF, displays only as the sender's details, i.e. name, address, date sent etc. I've tried saving as RTF and converting but when it

  • MINUS IN SQL PLUS

    Hi I have this query and it returns 4 records one of those is a duplicate SQL> col adjustment_reason format a30 SQL> SELECT account_no ,descr as adjustment_reason, 2 gl_id,amount as adjustmentamount 3 FROM src_misc_adj_rpt; ACCOUNT_NO ADJUSTMENT_REAS

  • RFC connection for nonSAP system

    Hi all i want to send and receive data from b/w SAP and NON-SAP systems. plz tell me which type of RFC connection i will use. Regard Imran Khan

  • Random number issue

    I'm making a mobile game and I can't seem to generate a random number successfully Game.java: import javax.microedition.lcdui.*; import javax.microedition.midlet.*; public class Game extends MIDlet implements CommandListener { private Display theDisp