Promise 378 - RAID 0 - Recovery settings required

I have a K8T NEO FISR motherboard with two Samsung 80gb SATA drives connected in RAID 0. Things were going along fine for the last several months and suddenly a couple of days ago, something went wrong and one of my drives dropped out of the array. Yes, it was stupid not having a current back-up of my hard drive, but regardless I am now trying to recover my files. They seem to be there, and a couple of different programs I'm playing with seem to be able to recover the files but they are corrupted. In looking at the files, especially JPG's it seems like the way the files are meshed is incorrect, and so I'm trying to find the default settings for the Promise 378 RAID 0 configuration.
I'm trying a program called  File Scavenger and its asking for:
First Sector for both drives
Striping Block Size - I believe this is 128kb per the information displayed in the Promise 378 raid configuration
Data Blocks per Parity Group
Boot Sector - defaults to 319 but not sure if this is correct
From the way the pictures look, I think perhaps the setting that is causing me the most trouble is the First Sector location for the second drive... but being able to confirm all settings would be rather nice also.
Any help or suggestions are appreciated,
Cheers,
Arba

Yep - both drives got the long version of the Seagate Disk Tools test, and both passed without a hitch. That's five hours of my life I'll never get back.
Anyway - the Promise TX2300 RAID card arrived yesterday, so I disabled the motherboard Promise in the BIOS, installed the card in a spare PCI slot (my last one!), and connected the drives. It turns out that this card also wont recognise the cards at 3 Mb/s, but they worked instantly when the drive jumper was replaced to limit them to 1.5 Mb/s. Partitioned and formatted I now have a working 2 x 500 Gb RAID 1, though I'm going to leave it a week before I move anything important onto it.... er, 'just in case'.
To summarise, the motherboard Promise and this new Promise RAID card use different silicon so their implementations could be different, but neither would talk to the drives at 3 Mb/s. I strongly suspect the Seagate drives have a SATA2 problem. I could easily be wrong of course, but I'm off to the Seagate forums now to try and pin it down.
Dufflepod.

Similar Messages

  • Promise 378 RAID controller wierdness

    Motherboard:        MS-6728  865PE Neo2
    Main BIOS:           AMI v2.5 29th Sep 2004
    Promise 378 BIOS:  v1.00.0.27
    Disks connected to promise S-ATA RAID connectors:  2 x Seagate ST2500630 500 Gb SATA2
    Serious instability in Promise 378 raid. Over a few cold reboots, can get each of the following in the BIOS screen, with no way of predicting which:
        RAID OK and functional
        Channel 1 fail array critical
        Channel 2 fail array critical
    I have replaced SATA leads, swapped the disk connectors around, and beefed up the power supply to 850 Watts, but with no joy, and this is before we even get into windows.
    If the array actually does identify OK and XP boots, trying to format the drive gives lots of these device timeouts in the system event log:
        The device, \Device\Scsi\fasttx2k1, did not respond within the timeout period.
    I have downloaded the lowlevel drive utility S/W from the Seagate website, and both drives have checked out OK when connected through the 'normal' ICH5 SATA connectors..
    So I've basically I've bought 1 Tb of disk space and an 850W power supply and can't do anything with it. Are the any issuse with these BIOS versions? Any help/suggestions all gratefully received.
    Many thanks,
    Tony

    Yep - both drives got the long version of the Seagate Disk Tools test, and both passed without a hitch. That's five hours of my life I'll never get back.
    Anyway - the Promise TX2300 RAID card arrived yesterday, so I disabled the motherboard Promise in the BIOS, installed the card in a spare PCI slot (my last one!), and connected the drives. It turns out that this card also wont recognise the cards at 3 Mb/s, but they worked instantly when the drive jumper was replaced to limit them to 1.5 Mb/s. Partitioned and formatted I now have a working 2 x 500 Gb RAID 1, though I'm going to leave it a week before I move anything important onto it.... er, 'just in case'.
    To summarise, the motherboard Promise and this new Promise RAID card use different silicon so their implementations could be different, but neither would talk to the drives at 3 Mb/s. I strongly suspect the Seagate drives have a SATA2 problem. I could easily be wrong of course, but I'm off to the Seagate forums now to try and pin it down.
    Dufflepod.

  • Promise 378 SATA Raid question

    Can someone tell me if my SATA drives are setup correctly given the details below?  The only driver that works is the FastTrak 378 (not the SATA 378 driver).  I want to make sure I am taking full advantage of my SATA drives.  In the Promise setup it shows them operating as "Mode U5".  What is this?
    Any help appreciated.
    My Drive COnfiguration is as follows:
    SATA Drives are on SATA3 & SATA4 (Promise 378 Controller)
    (as RAID 0 for performance)
    Primary IDE Master - Sony DVD/RW
    Primary IDE Slave - not used
    Secondary IDE Master - ASUS DVD ROM
    Secondary IDE Slave - ATA 133 Drive bay (Empty)
    3rd IDE Master&Slave - not used
    On Board Promise settings
    FastTrak 378 BIOS Ver 1.00.0.27
    2+0 Stripe - Functional
    HIT CTRL+F for setup and
    (in the setup it shows RAID 0 Drive Array as Mode U5)
    Bios Settings
    Boot Device Priority
    1 - Floppy
    2 - ASUS DVD ROM
    3 - BBS-0(RAID):FT 378 Ary 1
    On Board Promise IDE - As RAID
    On Chip ATA's Operation Mode - Legacy Mode
    ATA Configuration - PATA only
    SATA Keep enabled - no
    * PATA Keep enabled - no
    PATA channel selection - both
    * Combined Mode Option - PATA First Channel
    * SATA Ports Definition - P0-3rd/P1-4th
    * Configure SATA as Raid - no
    (where * is greyed out)
    Bios sees both DVD ROM & Sony DVD/RW
    Boot to CDROM
    Start Windows 2000 install
    F6
    "S"
    load Promise FastTrak 378 Controller
    Windows 2000 setup continues...

    Everything looks good to me. Like Danny said though, you will need to change Bios to "Native Mode" for the Intel controller if you ever intend to use the Serial connectors. If not you're fine.
    Also it's not clear from your post if you understand that you are using the 2 SATA drives as a Raid array. This gives you better drive performance but increases the chance of losing data. MAKE REGULAR BACKUPS.
    The Promise SATA drivers are for using the Serial1&2, IDE3 connectors with single/separate drives where Raid arrays are not used.

  • HT4718 No 1.    I can not activate Filevault : FileVault can't be turned on for the disk "Macintosh HD". Some disk formats don't support the recovery partition required by encryption. To use encryption, reinstall this version of Mac OS X on a reformatted

    I have TWO PROBLEMS
    No 1.  I can not activate FileVault. It displyas as follows :
    FileVault can’t be turned on for the disk “Macintosh HD”.
    Some disk formats don’t support the recovery partition required by encryption. To use encryption, reinstall this version of Mac OS X on a reformatted disk.
    No 2. I can not activate Find My Mac service. It displays as follows :
    Find My Mac requires a recovery partition
    Some configurations, such as software or hardware RAID, do not support a recovery partition and can't be used with find my mac

    Restart holding down the option/alt key and see if you have a Recovery Volume.
    Recovery Partition – Recreate Without Reinstalling
    Recovery Partition – Recreate Without Reinstalling (Requires Installer)
    Recovery Drive – Restore Missing
    Recovery Disk Assistant

  • Intel ICH5R or Promise 378 as S-ATA HDD controller?

    Which one is better and faster choice? My pc configuration is shown in my signature.
    Which of the controllers will give me better performance?
    Thanks in advance...

    hey guys, I have a theory.
    Since Promise 378 s running on PCI bus, while ICH5R SATA has its 100MHz clock locked and independent of overclocking, I am interested to know whether overclocking the PCI bus and hence increase the performance of Promise 378 SATA RAID devices would show any improvement over the ICH5R? ATA100 or ATA133 doesn't make much difference as our HDD nowadays are still running quite slow.

  • Promise 378

    Hi there, I have installed Vista home Premium on my Neo 875 mobo. It holds a intel RAID and a promise 378 controller. Everything works, but the promise controller. I have tryed several drivers included the latest I could find. the 1.0.0.39/41 driver. Vista accepts the driver, but is not finalising the installation and freezes. No error codes.
    Does anybody have a driver or a workaround, that lets me install so that I can connect my SATA drive on the controller? I am not going to use it in raid, but only as sata controller.
    Regards
    Neo

    Quote from: Neiwintro on 15-February-07, 15:23:08
    Hello - I have checked the promise website, but no findings there. as I wrote, i do not use the controller as RAID. I have enabled it in bios as SATA and Vista finds the controller. When I load the driver Vista accepts it, but dont finalize the installation. I have tryed the newest driver from MSI with no luck and a driver 39/41 that others seam to have gotten to work.
    I haven´t tryed the one MJ is using. But i will to night - thx.
    I have a single 320 GB SATA1 disk on the controller. I worked fine when i had XP installed.
    My system is as following:
    2 80 GB SATA 1 disks in raid 1 on the intel controller.
    a pioneer DVD burner on the first pata controller
    1 80 GB PATA om the second pata controller
    a 320 sata 1 on the promisecontroller
    P4 3 Ghz cpu
    1 Gb RAM
    And I hope that I can use it until this summer. when I plan to build a new PC
    Thx
    Neo
    I have successfully installed Vista Ultimate on 2xSATA raid 1 on intel controller for testing purpose.  The Promise controller without RAID works perfectly with the driver version 1.0.0.26 (which I have used earlier) without any problem.  If you need the driver, please drop me an email via emailremovedbymoderator.  The driver version 1.0.0.39 has a problem in starting up.
    Regards,
    MJ
    I removed your email address from the post to protect you from spam and such. PM the guy your address to give him the contact.
    Frankenputer

  • Icloud find my mac recovery partition required

    Hey People
    I just saw that in my Icloud settings.
    Find my mac and grayed out and show a error saying recovery partion required. how do i fix this?
    here a screen shot.

    Kappy wrote:
    If you can open the App Store now, see if you are able to download the Lion installer. If you can (it's not likely) then do so. After the installer is downloaded it will open automatically. You need to Quit the installer at that point - DO NOT install. Copy the installer to your Downloads folder. Then see the following:
    Make Your Own Mountain/Lion Installer
    1. After downloading Mountain/Lion you must first save the Install Mac OS X Mountain/Lion application. After Mountain/Lion downloads DO NOT click on the Install button. Go to your Applications folder and make a copy of the Mountain/Lion installer. Move the copy into your Downloads folder. Now you can click on the Install button. You must do this because the installer deletes itself automatically when it finishes installing.
    2. Get a USB flash drive that is at least 8 GBs. Prep this flash drive as follows:
    Open Disk Utility in your Utilities folder.
    After DU loads select your flash drive (this is the entry with the mfgr.'s ID and size) from the left side list. Click on the Partition tab in the DU main window.
    Under the Volume Scheme heading set the number of partitions from the drop down menu to one. Set the format type to Mac OS Extended (Journaled.) Click on the Options button, set the partition scheme to GUID then click on the OK button. Click on the Partition button and wait until the process has completed.
    Select the volume you just created (this is the sub-entry under the drive entry) from the left side list. Click on the Erase tab in the DU main window.
    Set the format type to Mac OS Extended (Journaled.) Click on the Options button, check the button for Zero Data and click on OK to return to the Erase window.
    Click on the Erase button. The format process can take up to an hour depending upon the flash drive size.
    3. Locate the saved Mountain/Lion installer in your Downloads folder. CTRL- or RIGHT-click on the installer and select Show Package Contents from the contextual menu. Double-click on the Contents folder to open it. Double-click on the SharedSupport folder. In this folder you will see a disc image named InstallESD.dmg.
    4. Plug in your freshly prepared USB flash drive. You are going to clone the content of the InstallESD.dmg disc image to the flash drive as follows:
    Double-click on the InstallESD.dmg file to mount it on your Desktop.
    Open Disk Utility.
    Select the USB flash drive from the left side list.
    Click on the Restore tab in the DU main window.
    Select the USB flash drive volume from the left side list and drag it to the Destination entry field.
    Drag the mounted disc icon from the Desktop into the Source entry field.
    Double-check you got it right, then click on the Restore button.
    When the clone is completed you have a fully bootable installer that you can use without having to re-download Mountain/Lion.
    Note: The term Mountain/Lion used above means Lion or Mountain Lion.
    Now boot the computer from your USB flash drive.
    Erase the hard drive:
    Select Disk Utility from the main menu and click on the Continue button.
    After DU loads select your startup volume (usually Macintosh HD) from the left side list. Click on the Erase tab in the DU main window.
    Set the format type to Mac OS Extended (Journaled.) Click on the Erase button and wait until the process has completed.
    Quit DU and return to the main menu.
    Reinstall Lion: Select Reinstall Lion and click on the Install button.
    Note: You will need an active Internet connection. I suggest using Ethernet if possible because it is three times faster than wireless.
    I under stand it a good idea to keep a backup of loin install. But why do i have to. Not hard just to redownload it. only 3.8 Gb.
    Dont have a usb can you do it on a DVD still? do i need to do this?

  • What are the settings required for QM in procurement

    Hi Team,
    What are the settings required for QM in procurement. I have  set indicator for QM in procurement in QM view in material master.
    I am not clear about  following fields to be maintained in QM view.
    QM Control Key
    Certificate type
    Target QM system
    Tech. delivery terms Indicator.
    Please suggest me in which case to be used this fiels. Is it relivant to Quality Certificates.
    Thanks

    Hi,
    All meaning are
    QM Control Key :
    If you activate the indicator for QM in procurement in the material master record at the client level, you must also store a control key at the plant level for quality management in procurement.
    Certificate type :
    Certificate types applies to the Certificate processing in procurement  &  Certificate creation
    Target QM system :
    whether the vendor's verified QM system, according to vendor master record or quality info-record (for a combination of vendor/material) meets the requirements for QM systems as specified in the material master
    -  If you activate the indicator for QM in procurement in the material master record at the client level, you must also store a control key at the plant level for quality management in procurement. If you want Procurment control then accordingly define Control Key.
    -  If you want Vendor's perticular certificate for Material then you have to define Certificate type.
    Also, you have to maintain Material, Vendor's Info record at plant level.
    Thanks,
    JM

  • Error during Backup/Recovery settings configuration

    Hi all,
    Using the Oracle Enterprise Manager 10g Application Server control,
    i am configuring backup/recovery settings for my infrastructure tier in a 10g Rel 2 application server environment. however after specifying the various locations for Log Files, Configuration files, Metadata repository database backup etc i get the following error after clicking the 'Ok' button.
    An Internal Error has occurred while performing the operation.
    Performing configuration ...
    oracle_sid: cinfra
    The command /oracle/appn/oracle/infra/perl/bin/perl /oracle/appn/oracle/infra/backup_restore/bkp_restore.pl -m configure -h /oracle/appn/oracle/infra -f > /infrahome/backups/log_files/2009-12-06_17-13-38_output.log failed with return code 255
    i am at a loss as to why i am having this error and how to fix it.
    I examined the log file and saw an error snippet saying
    *"Unable to get dbid from the database. Please ensure that ORACLE_HOME and ORACLE_SID are set to the same values used when starting up the database and that the database is open.... Failure: Configure failed"*
    Also examined another file generated at the same time as the output log file and in there i saw the following
    *"ld,so.1: oracle: fatal: relocation error: file /oracle/appn/oracle/product/10.2.0/cm2t/lib/libjox10.so: symbol kgestKguard_: referenced symbol not found*
    *ERROR:*
    *ORA-12547: TNS: lost contact*
    *SP2-0751: Unable to connect to oracle. exiting SQL*Plus"*
    Apart from the infrastructure database, i have another database with SID 'cm2t' on the same machine and i am suspecting that OEM Application server control is referencing the wrong file while it's doing it's work. How do i tell it to look in the right place if indeed that is the cause of my problem?
    In my config.inp file all the right parameter values are in place.
    Thanks.
    Steve.

    Hi AMN,
    Thanks for your reply. I managed to solve it by taking the following steps.
    I use the runstartupconsole.sh script to start up my infrastructure tier. At startup it was using an LD_LIBRARY_PATH pointing to that used by an existing Oracle database instance on the same machine.
    I set ORACLE_HOME, ORACLE_SID, LD_LIBRARY_PATH etc correctly before running the runstartupconsole.sh script and after that i was able to setup my backup/recovery settings properly.
    I hope this will be useful to others.
    Steve.

  • What are the settings required to block a particular IP to make connection on particular port no running on another IP?

    Problem:
    -   What are the settings required to block a particular IP to make connection on particular port no running on another IP?
    Environment:
    Operating System            : - Windows XP Service
    Pack 1
    System type                     : - 32 – bit Operating System
    Description: - We
    have requirement to block Port access from particular IP. It is specific requirement for a machine.
    We have service which is running on
    Server with IP: - 10.14.15.116 on
    Port Number 3366 and we need to
    block Client Machine IP: - 10.14.15.114 to make
    any connections with server on this port. Not even client machine
    should be able to telnet on server on port 3366.
     I
    will be really thankful.
    For any kind of input which can assist us to complete the requirement.

    Does it allow in same way with firewall setting in Windows Server 2008?
    I will read in details shared link, but as a matter of urgency; kindly let us know, if we can follow some concise instruction to do above activity.
     I
    will be really thankful

  • BW settings required when we change the host name in R/3

    Hi All,
    we had a test system in R/3 and we are planning to change the Host name in R/3 and this is connected to bw test.after basis change the host name in r/3 test what are settings required to be done in BI .
    Regards,
    jasmine.

    after name change check the RFC connection in SM59 and then see if you data sources are anabled from new source system.

  • How to put restriction/variable in BI 7.0 ? Is there any settings required?

    Hello,
    I am working on BI 7. I want to know ""How to put restriction/variable in BI 7.0 ? Is there any settings required? I am putting some variables in BI 7.0 while making some query""
    amit shetye.

    Hi Amith,
              just create a new query  like a previous  versions how u create..  and  now  select particular charecterstic  in the  left side window itself.. and drill down it.. and create  a variable..  and assign all the properties to that variable.. now  drag that particular variable.. in to the Rows  or filters..
         for Restrictions...  put any charecterstics into Free charecterstics.. and right clcik that and select  Restriction. now you need to give  the  values.. based on that  it will  RESTRICT THE VALUES..
    BI 7.0 reporting features
    http://searchsap.techtarget.com/cgi-bin/rd.pl/ftID-1121728-ctID-1064004?//expert/KnowledgebaseAnswer/0,289625,sid21_gci1064004,00.html
    http://help.sap.com/saphelp_nw04s/helpdata/en/9d/24ff4009b8f223e10000000a155106/content.htm
    https://www.sdn.sap.com/irj/sdn/developerareas/bi?rid=/webcontent/uuid/ba95531a-0e01-0010-5e9b-891fc040a66c [original link is broken]
    http://help.sap.com/saphelp_nw04s/helpdata/en/43/F9D041D6392AE3E10000000A422035/frameset.htm
    BI7.0
    For greater information on reporting.....
    Good Knowledge in BW Reporting
    regards
    @jay

  • Customization settings required for Extenal service managment

    Hi,
    Till now we are not using External managment , now we want to confifure this  , so what are the settings required for this.
    regards,
      zafar

    Hi,
    1. If you are selling the Service , Use Material Type u201CDIENu201D and for billing with SD module ,u have to use MM with HR module like (Time & Material ) ie…..Expense recording (PR05) then PRRW and PRFI.
    2 .If vendors provide service for you and you can procure the service and pay to vendor.
    The configuration required are:
    2.1. Define organization status for service category
    SPRO u2013>MM-> ESM->Service master- >Define organization status for service category
    2.2. Define Number Ranges
    SPRO u2013>MM-> ESM->Service master- >.Define Number Ranges
    2.3. Define Service Category
    SPRO u2013>MM-> ESM->Service master- > Define Service Category
    & you can do assignment of cost object ( cost center, project, sales order) with co.code with G/L account in OKB9 t.code and in t.code OBYC account assignment of GBB,WRX with G/L.
    ***After above you can create Master data as Service master AC03
    & the transactions are
    A. Create PO ME21N (Acc,assment cat. K or P or C as required and item category D) and enter other detail with service master.
    B. Create SES w.r.t. PO in ML81N
    C. MIRO w.r.t. SES
    D. Payment to vendor in F-53
    For more Check the link:
    http://sapmm.wordpress.com/category/esm/
    Regards,
    Biju K

  • Initial settings required for Made to Stock -10 strategy.

    Dear Frndz,
    Kindly help me with the step by step procedure to do the initial (SPRO) settings required in SAP PP to carryout the Made to Stock -10 strategy in the system.
    Regards,
    Srini

    Hi,
    For MTS, maintaining the Planning Starategy 10 in Mtrial MAster is the Only thing we need to do.
    System by default will do the rest of the things for you.
    In MD61, system will propose Requirements Type LSF.
    Sales Order will be for Inforamtion Purpose.
    PIR will be reduced after PGI to the SO.
    If you require any specific thing pl. inform.
    Regards,
    Siva

  • Spro settings required to do Reservation?

    Hi Gurus,
    what are the settings required to do reservation?
    pls help..

    Hi, 
    you need to check the customization settings in SPRO  MM --  Inventory Management and Physical Inventory ---  Reservation
    Most imp is in  OMBK it chould be checked against your t- code