Dear All,
How is the PS module and SD Module are integrated?
I am thinking  the linjk is only through the WBS element .please guide me if am wrong.
But I am not able to get the data flow across these two modules.
Is there any other setting to be done in the IMG ?
My client scenario needs a close interaction(flow) of data from PS to SD
I am trying to establish this llink through DIP profile and RRB .As i am not familiar
either with DIP Profile or with RRB.In these circumstances i seek your help.
Rewards are assured for timely & valuable help.
Thanking you,
Best Regards,
R.Srinivasan

Hi Ramanujam,
Please find below the complete stuff reg PS integration with SD Module:
SD INTGRATON WITH PS (Project Systems)
PS SD integration happens during Milestone billing...
Below is whole process-
Billing Plan for Milestone Billing
Milestone billing means distributing the total amount to be billed over multiple billing
dates in the billing plan.
As each milestone is successfully reached, the customer is billed either a percentage of
the entire project cost or simply a pre-defined amount.
During sales order processing, the system determines from the item category whether a
billing plan is required and, if so, which type of plan
The type of billing plan that is determined at this point is set up in Customizing and
cannot be changed in the sales document.
Billing plans for periodic billing and milestone billing plans for project-related milestone
billing have different overview screens so that you can enter data relevant to your
processing.
For example, for milestone billing, you must be able to enter data to identify the
individual milestones.
IMG configuration requires:-
1. Maintain billing plan types for milestone billing in OVBO.
2. Define date description in SM30 - V_TVTB.
3. Maintain Date Category for Billing Plan Type IN OVBJ.
4. Allocate date category in SM30 - V_TFPLA_TY.
5. Maintain date proposal for Billing Plan Type in OVBM.
6. Assign Billing Plan Type to Sales Documents Type in OVBP.
7. Assign Billing Plan Type to Item Categories in OVBR.
8. Define rules for determining the date in OVBS.
Milestone billing is typically used for billing projects, such as plant engineering and
construction projects. Such projects often include a series of milestones that mark the
completion of different stages of the work. In the SAP R/3 System, milestones are defined
in a network along with planned and actual dates for the completion of work. The milestones
are also assigned to the billing dates in the billing plan.
Each milestone-related billing date is blocked for processing until the Project System
confirms that the milestone is completed.
Delivery-relevant order items for which a milestone billing plan applies are billed on the
basis of the requested delivery quantity and not on the total of the confirmed quantities.
The connection between the project and the sales document item is made in the individual
schedule lines of the item. Each schedule item can be assigned to a network in a project.
To display the project-related data for a schedule line, proceed as follows:
In one of the overview screens of the sales document, select
1. Item -> Schedule lines.
2. Mark the schedule line and select Procurement details.
The following figure shows an example of milestone billing where only the Contract have
been billed :
Order Item Turbine 100,000
Billing Plan
Billing date Description % Value Billing Block Milestone Billing Status
01-10-94 Contract 10 10,000 - x x
01-03-95 Assembly 30 30,000 x x
01-04-95 Maintenance 30 30,000 x x
01-05-95 Acceptance 30 30,000 x x
01-06-95 Final invoice .. .. x
Network/Activities
Milestone Estimate Actual
Assembly 01-03-95 01-03-95
Maintenance 01-04-95
Acceptance 01-05-95
For each billing date in a milestone billing plan, you can specify whether the billing
date is:
1. fixed
2. Always updated with the actual date of the milestone
3. Updated with the actual date of the milestone, if the date is earlier than the
planned billing date for the date
Following is the SD & PS integration scenarios where milestone billing & Periodic billing plays the important role for these integration:
Milestone billing is typically used for billing projects, such as plant engineering and
construction projects. Such projects often include a series of milestones that mark the
completion of different stages of the work. In the SAP R/3 System, milestones are defined
in a network along with planned and actual dates for the completion of work. The milestones
are also assigned to the billing dates in the billing plan. The connection between the project and the sales document item is made in the individual
schedule lines of the item. Each schedule item can be assigned to a network in a project.
PS-SD Integration as below:
A) Billing plan, at each WBS element, network and Activity level.
B)DIP profile which is assigend to item category. DIP for resource related quotation works only with ECP ( easy cost planning).
C)sales pricing - generally, there r 2 types of sales pricing in PS . lumpsum contract and unit rate contract.
D)BOS - bill of Services. which has to be activated. It is industry specific solution. If BOS is activated you also have integration for vendor RFQ and Analysis.
Further pls provide ME ur mail id , will mail some zip files regarding integration of SD module with all other module including PS.
Project System(PS) works for any project e.g construction, operation or any large projects where project management tools are required. it integrates all modules may be like MM for vendor process or for RFQ etc or say may be SD for Resource related quotation with the help of DIP profile or Milestone process etc. IT is largely used in construction projects. IT helps in controlling the whole of project from one single screen and it works with 3 elements WBS element ( work break down structure), Network and Activity.
Please go throgh this Please check this links perhaps they may help.
http://help.sap.com/bp_imcv1500/IMC_US/HTML/preconfigured_scenarios.htm
ETO:
http://help.sap.com/bp_imcv1500/IMC_DE/HTML/E83_EN_DE.htm
http://help.sap.com/bp_bblibrary/500/HTML/E46_EN_DE.htm
MTO:
http://help.sap.com/bp_bblibrary/500/HTML/V66_BB_EN_US.htm
http://help.sap.com/bp_imcv1500/IMC_DE/HTML/E70_MTOQuotProc_EN_DE.htm
PS - SD integration are on
1.Billing pan, at each WBS element, network and Activity level.
2. DIP profile which is assigend to item category. DIP for resource related quotation works only with ECP ( easy cost planning).
3.sales pricing - generally, there r 2 types of sales pricing in PS . lumpsum contract and unit rate contract.
4. BOS - bill of Services. which has to be activated. It is industry specific solution. If BOS is activated you also have integration for vendor RFQ and Analysis.
5. resource related Billing
The specified item was not found.
Please Reward If Really Helpful,
Thanks and Regards,
Sateesh.Kandula

Similar Messages

  • What are the  areas integrated for MM-PP module as well as MM-FI

    Dear    MM experts,
    In what are the  areas integrated for MM-PP module as well as MM-FI ?
    thanks
    saravanakumar

    Dear Saravana Kumar,
    Material Master data is integrated with all the modules not only PP & FI it also integrates with SD, QM, CO, PM and so on.
    (a) MM and PP Integration through MRP Type in material master
    (b) MM and FI Integration through Valuation Class in material master
    Hope this information will be useful
    Regards,
    Muralidhara

  • Ztable and Zfucntion module are stored in which SAP table

    Hi Guys,
    We use to create Ztable and Zfunction module in SAP, In which table are the table and function module name would store?
    Thanks,
    Gourisankar.

    Hi Gowri,
                 Tables stored based on the Package that is how you save if you save under any package it will saved under that package. similarly Function module are saved with respect to Function Group.
    Regards,
    Sathish

  • What modules are available in Ltd CRM, Ltd Logitic and Ltd Finance User.

    Dear All,
             I just want to know what modules are available in Ltd. CRM, Ltd. Logsitic and Ltd. Finance User.
            If possible can anybody give me the link from where i can get information which template is accessble by which user.
    Regards
    Hitesh Parsawala

    Hi Hitesh,
    Complete details about new user types is available in the service
    market place in the path mentioned below
    https://service.sap.com/smb
    > License Key Requests
      > Additional Documentation
        > New Pricing and Licensing structure
    Also, refer to SAP Note : 1223477
    Regards,
    Vijay kumar
    SAP Business One Forums Team

  • WS-X6848-SFP module are supported with LMS Prime 4.1 and 4.2

    Hi,
    I would like to know if WS-X6848-SFP modules are supported with LMS Prime 4.1 and 4.2.
    Thanks for your help,
    SILVIA

    It looks like they just added the WS-X6848-TX variant with the latest C6000IOS CiscoView package update (Version 37, dated 31 July 2012 - readme)
    I'd expect the -SFP variant should be in the next update.
    You should open a TAC case to make sure that it's brought to the attention of the dev team if they aren't already working on it. One of the tenets of Cisco Prime LMS is "Day 1 support" of new devices.

  • PP module is integrated

    How is PP module is integrated with SD?

    Dear Maulik,
    1.Creating production orders for sales orders using CO08 T Code in case of make to order.
    2.Availability checking rule assigned for the order's.
    3.Requirements class - Allocating requirement's type to a requirement class.
    Requirements classes control the creation of planned independent requirements or sales orders and customer requirements. The following is determined by the requirements class, for example;
    the consumption of independent requirements by sales orders
    how warehouse stock is taken into account (net or gross requirements planning)
    inventory management and cost allocation (make-to-order or make-to-stock production)
    the release of the planned order (planning without final assembly)
    requirements distribution (configuration)
    4.Creating Sales order BOM.
    The above are some of the integration between PP and SD Module.
    Regards
    Mangalraj.S

  • How Oracle ASCP and Inventory are integrated ,what are the Integration poin

    Hi All Gurus,
    Can any one tell me..
    How Oracle ASCP and Inventory are integrated ,what are the Integration point of these modules ...?
    Thanks,
    Satyam

    Here is a simplistic explanation on the the integration.
    When you launch data collection from the ASCP side, Oracle launches a Refresh Snapshot process that gathers the latest inventory (and other modules) information into Snapshots. Snapshots are like materialized views. Then the Planning Data Pull is launched. That process pulls information from these snapshots into the ASCP side.
    The following inventory information comes over to ASCP
    Item master data (such as order modifiers, planning exception sets etc. )
    item categories
    Onhand quantities (including consigned invetory quantities) in nettable locations
    subinventories
    reservations
    safety stocks
    forecasts
    item planners
    Quantity in receiving or in transit
    Hope this answers your question
    Sandeep Gandhi
    Independent Consultant
    513-325-9026

  • Memory Slot Utility "memory modules are installed in the recommended slots"

    I've got two Mac Pros that give me this message. Every time I boot them up the Memory Slot Utility gives me the message that my memory modules are installed in the recommended slots.
    This started after I installed an additional 8GB of RAM, bringing them up to 16GB. 8x2GB sticks.
    I checked the login items and it's not there, so what else could I be missing?

    I have this problem too on a Mac Pro Quad Early 2009.
    Has 2x4GB + 2x1GB Runs fine with 10GB, but everytime I log in the memory utility pops up as if I have a problem.
    How do I stop it annoying me?

  • How to find out what modules are used

    In /etc/rc.conf there are a lot of modules that are loaded that don't need to be, like modules related to OSS. Is there some command that'll show me what modules are being used at the moment and/or what they do?

    Yes Thinkpad FTW! Back on topic; so there are three columns: Module, Size and Used By. In the used by column what do the different numbers mean?
    I ran "lsmod | less" to be able to view each individual one. (That "| less" part is really useful)
    Last edited by jordanwb (2008-08-07 01:59:15)

  • Which c-series modules are compatible with Scan Mode?

    OK, so I just wasted 4 hours.
    I started a new Project with a need to use a 9220 analogue input card on a cRIO 9030, but immediately became stuck when I was unable to add the module using the right click Add New C-Series Module wizard to the 9030 chassis.
    My first (and only) assumption was that this was a new card and I needed the latest Device Drivers. So I installed those.
    When that failed I upgraded my LV2014 to LV2014 SP1, and also upgraded the Real-Time and FPGA modules too.
    4 hours later, when that failed, I realised that maybe this isn't a card compatible with Scan Mode so began searching ni.com for information. I've searched a whole raft of terms and I just cannot find information on which modules are supported by Scan Mode (which is presumably nearly all of them). I know it exists somewhere because I one referred to it when I had an RS485 module that was only compatible in FPGA mode, about four years ago.
    So:
    1. Is there an easy way to determine if a C-Series module is compatible with Scan Mode? I still don't know!
    2. Can we please have Scan Mode compatibility shown in the Add C-Seris Module Wizard. When attempting to add a module to a cRIO chassis, the wizard can hint to us that a particular module is not compatible. By not showing the 9220 in the drop down list I was led to believe the module was not a known device (and hence I attempted to upgrade my drivers). It would be better if the module was listed but disabled and not selectable, with some informational text to explain why. It's a fair assumption that a module will be compatible, so we don't expect it to not be listed when we attempt to add it. In fact, the possibility that some modules aren't compatible can evade your consciousness temporarily and make you do stupid things (like upgrade your installation!).
    3. Can we please have Scan Mode compatability information put on each module's description page. That would have made this whole process much quicker.
    Thoric (CLA, CLED, CTD and LabVIEW Champion)

    Well, I definitely agree that finding info about RSI module support is not as easy as it should be. Since I know where to look, I will refer you to this document, which I found linked from this page.
    That's the best document I know of on the topic.
    Cheers!
    TJ G

  • How many types of function modules are there

    hi gurus,
    how many types of function modules are there...
    what type of function module bapi  is....
    i don't know much about that...
    pls help me...
    regards,
    praveen

    hi
    hope it will help you.
    <REMOVED BY MODERATOR>
    Function Modules Used in Script:
    In the Driver Program we must use all or some of the function modules that are listed below to transfer the data.
    • Open_Form
    • Close_Form
    • Start_Form
    • Write_Form
    • Write_Form_Lines
    • End_Form
    • Control_Form
    • Read_Form_elements
    • Read_Form_Lines
    Any driver program must contain Open_Form, Close_Form and Write_Form. Other function modules are optional.
    OPEN_FORM: This function module opens layout set printing. One must call this function module before he uses any of other layout set function modules like Write_Form, Start_Form, Control_Form etc., You need specify a layout set name in the export parameters of this function module. If nothing is passed to Open_Form then one should use Start_Form function module to open layout set before starting the output. The layout set opened by Open_Form should be closed by Close_Form function module, other wise output doesn’t appear. We can use any number of Open_Form, Close_Form functions in one single program. But Close_Form must be there for every Open_Form in the program.
    Some of the important export parameters we have to pass to Open_Form function module.
    Form: Enter the Layout set name here, which then controls the output formatting. If nothing is specified then we must use Start_Form for opening layout set.
    Language: Layout sets are Language dependent. Enter the desired language here. If the entered layout set is not in that language, then the function tries to open the Form entered in its original language. The default value is SY-LANGU.
    Device: SAP Script can format a text on different device types. The device can be ‘PRINTER’ or ‘TELEX’, ‘TELEFAX’, ’ABAP’ and ‘SCREEN’.
    Dialog: Use parameter DIALOG to determine whether to display a dialog box before printing, in which the user can set several spool parameters for print formatting. Possible values: SPACE displays no print parameter screen. 'X' display print parameter screen. Default value: 'X'
    Options: Use parameter OPTIONS to set several options for print formatting. The parameter has the structure ITCPO. The user can change some of the defined settings on the print control screen. The default value for Options is ‘ ‘. We will discuss about ITCPO structure in detail later.
    Other Export, Import and Exceptions are self-explanatory.
    Close_Form: The function module closes the layout set opened using OPEN_FORM. The system executes any terminating processing steps for the last opened layout set. No Export parameters for this Function Module.
    Start_Form: In-between the function modules OPEN_FORM and CLOSE_FORM, we can use different layout sets. This allows us to combine several different layout sets into one print output. However, we can combine only those layout sets that have the same page format. To switch layout sets, use the function module START_FORM. If another layout set is still open, we must close it first using END_FORM. If we specify no layout set name when calling START_FORM, the system restarts the last open layout set. If after OPEN_FORM no layout set was activated yet, the system leaves the function module with the exception UNUSED. Some of the important export parameters for this function module are
    Form: The parameter contains the name of the layout set you want to use for printing. If you specify no layout set here, the system restarts the last active layout set.
    Language: Layout sets are language-dependent. Enter the desired language here. If the layout set does not exist in this language, the system tries to call the layout set in its original language. If the parameter LANGUAGE is empty, the system uses the language of the last active layout set.
    Startpage: Usually, SAP script starts with the page specified as start page in the layout set definition. If we want to start output with another layout set page, enter the name of the desired layout set page here. If the desired page is not defined, the system uses the start page defined in the layout set.
    Program: To replace program symbols, SAP script must know which active program contains the work areas for the values to be passed. If we omit the parameter, the system searches for the field values in the program that was specified in the parameter OPTIONS (field TDPROGRAM) of OPEN_FORM. If we enter a program name, the system replaces the program symbols with the values from this program up to the next END_FORM.
    Exceptions and other Export, Import parameters are self-explanatory.
    Write_Form: The system outputs the layout set element specified in parameter ELEMENT into the currently opened layout set. In the parameter WINDOW we can specify the name of a window for the output. Remember that the layout set element must be defined in this window. The parameter FUNCTION specifies how to merge the text lines to be output with any existing contents in the window. In this case, there are differences between the different window types or areas. Some of the important export parameters used in Write_Form.
    Element: Specify the name of the text element you want to output into the layout set window specified in the parameter WINDOW. The element must be defined in that layout set window. If you specify no element, the system uses the default element, if one is defined in the layout set.
    Window: Specify the name of the window into which you want to output the layout set element specified in the parameter ELEMENT. Default value for Window is ‘MAIN’.
    Function: The parameter determines how to output the text element into the respective window. The output type depends on the window type and area:
    Window Type: MAIN Area: BODY
    SET/APPEND: Appends to previous output.
    Window Type: Main Area: Top/Bottom and
    Window Type: Other than Main and all areas
    SET : Delete the old element contents and prints the new elements
    APPEND: Appends the new content to existing elements.
    Type: The system interprets this parameter only for output to the main window. The parameter determines the area of the main window into which we want to output the element. Possible values: 'TOP' header area
    'BODY' main area
    'BOTTOM' footer area
    Default value: 'BODY'
    Write_Form_Lines: This function module outputs the text lines in table LINES into the specified layout set window. The text lines must have the SAP script ITF format. From the data in the text header, the system uses only the field TDSTYLE to apply the formatting attributes defined in the specified style for this text. If the field is empty, the system uses the identically named formatting attributes (character and paragraph formats) of the layout set.
    Use parameter WINDOW to specify into which of the windows defined in the layout set we want to output the text. We can specify any window used in the layout set. The parameter FUNCTION determines how to merge the text lines to be output with any existing contents in the window. There are differences between the different window types or areas.
    Header: This parameter contains the header of the text module we want to output in the current layout set. For the formatting process, the system uses only the entries in the header fields TDSTYLE and TDFORM. Structure: THEAD
    WINDOW: Enter the name of the window into which we want to output the layout set element specified in parameter ELEMENT. Default value: 'MAIN'
    FUNCTION: This parameter determines how to output the text element into the respective window. The output type depends on the window type and area: Window type MAIN, area BODY: 'SET' append to previous output 'APPEND' same as SET. DELETE' no effect. Window type MAIN, areas TOP and BOTTOM; all other windows: 'SET' delete old window or area contents and output the element 'APPEND' append the element to the existing elements 'DELETE' no effect Default value: 'SET'
    TYPE: The system interprets this parameter only for output to the main window. The parameter determines the area of the main window into which you want to output the element. Possible values: 'TOP' header area 'BODY' main area 'BOTTOM' footer area Default value: 'BODY'
    END_FORM: END_FORM ends the currently open layout set and executes the required termination processing. After calling this function module, no more layout set is active. For further output, we must start a new layout set using START_FORM. No Export parameters.
    CONTROL_FORM: Use this function module to pass SAP Script Control Commands to the layout set. The Control command is passed through the export parameter ‘COMMAND’ in quotes.
    READ_FORM_ELEMENTS: This function module fills a table with all text elements that appear in one layout set. If we specify no layout set name, the system includes all elements of the currently open layout set. If we specify a layout set, the system uses the information about the active version of the layout set, retrieved from the database. Here we have two export parameters, Form and Language and a table parameter Elements.
    READ_FORM_LINES: Use this function module to transfer the lines of a layout set element into an internal table. If we specify no layout set name, the system transfers the text lines of the currently open layout set. If we specify a layout set, the system uses the text lines of the active version of the layout set from the database. The Export parameters are Form, Language, Window and Element. If we pass these 4 parameters the function module returns a table with the lines from layout set.
    Function modules are one element. There are no types. However sometimes an RFC enabled function module is referred to as RFC Function module, but really it is just a function module. Also BAPIs are function modules, but are usually referred to as just BAPI as opposed to BAPI Function module.
    There is no different function module types , but calling the function module will be different.
    check this function calls syntax
    1. Calls a function module:
    CALL FUNCTION func.
    2. Call a function module in a different mode (asynchronous Remote Function Call):
    CALL FUNCTION func STARTING NEW TASK taskname.
    3. Call a function module in the update task:
    CALL FUNCTION func IN UPDATE TASK.
    4. Call a function module in a remote system (Remote Function Call, RFC ):
    CALL FUNCTION func DESTINATION dest.
    5. Asynchronous call to a function module with transactional processing (transactional Remote Function Call):
    CALL FUNCTION func IN BACKGROUND TASK.
    qRFC with output queue
    6. Call a function module that can be activated in the context of enhancements:
    CALL CUSTOMER-FUNCTION func.
    Cheers,
    Chandru
    Edited by: Alvaro Tejada Galindo on Feb 27, 2008 11:53 AM

  • Hi guru's what are the function modules are used in ALV

    hi guru's what are the function modules are used in ALV

    Hi vasu,
    There are some function modules which will enable to produce the  reports without much effort.
    All the definitions of internal tables, structures and constants are declared in a type-pool called SLIS.
    1. SIMPLE REPORT.
    The important function modules are
    a. Reuse_alv_list_display
    b. Reuse_alv_fieldcatalog_merge
    c. Reuse_alv_events_get
    d. Reuse_alv_commentary_write
    e. Reuse_alv_grid_display
    A. REUSE_ALV_LIST_DISPLAY : This is the function module which prints the data.
    The important parameters are :
    I. Export :
    i. I_callback_program : report id
    ii. I_callback_pf_status_set : routine where a user can set his own pf status or change the functionality of the existing pf status
    iii. I_callback_user_command : routine where the function codes are handled
    iv. I_structure name : name of the dictionary table
    v. Is_layout : structure to set the layout of the report
    vi. It_fieldcat : internal table with the list of all fields and their attributes which are to be printed (this table can be populated automatically by the function module REUSE_ALV_FIELDCATALOG_MERGE
    vii. It_events : internal table with a list of all possible events of ALV and their corresponding form names.
    II. Tables :
    i. t_outtab : internal table with the data to be output
    B. REUSE_ALV_FIELDCATALOG_MERGE : This function module is used to populate a fieldcatalog which is essential to display the data in ALV. If the output data is from a single dictionary table and all the columns are selected, then we need not exclusively create the field catalog. Its enough to mention the table name as a parameter(I_structure name) in the REUSE_ALV_LIST_DISPLAY. But in other cases we need to create it.
    The Important Parameters are :
    I. Export :
    i. I_program_name : report id
    ii. I_internal_tabname : the internal output table
    iii. I_inclname : include or the report name where all the dynamic forms are handled.
    II Changing
    ct_fieldcat : an internal table with the type SLIS_T_FIELDCAT_ALV which is
    declared in the type pool SLIS.
    C. REUSE_ALV_EVENTS_GET : Returns table of possible events for a list type
    Parameters :
    I. Import :
    Et_Events : The event table is returned with all possible CALLBACK events
    for the specified list type (column 'NAME'). For events to be processed by Callback, their 'FORM' field must be filled. If the field is initialized, the event is ignored. The entry can be read from the event table, the field 'FORM' filled and the entry modified using constants from the type pool SALV.
    II. Export :
    I_List_type :
    0 = simple list REUSE_ALV_LIST_DISPLAY
    1 = hierarchcal-sequential list REUSE_ALV_HIERSEQ_LIST_DISPLAY
    2 = simple block list REUSE_ALV_BLOCK_LIST_APPEND
    3 = hierarchical-sequential block list
    REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_COMMENTARY_WRITE : This is used in the Top-of-page event to print the headings and other comments for the list.
    Parameters :
    I. it_list_commentary : internal table with the headings of the type slis_t_listheader.
    This internal table has three fields :
    Typ : ‘H’ – header, ‘S’ – selection , ‘A’ - action
    Key : only when typ is ‘S’.
    Info : the text to be printed
    E. REUSE_ALV_GRID_DISPLAY : A new function in 4.6 version, to display the results in grid rather than as a preview.
    Parameters : same as reuse_alv_list_display
    This is an example for simple list.
    2. BLOCK REPORT
    This is used to have multiple lists continuously.
    The important functions used in this report are:
    A. REUSE_ALV_BLOCK_LIST_INIT
    B. REUSE_ALV_BLOCK_LIST_APPEND
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    A. REUSE_ALV_BLOCK_LIST_INIT
    Parameters:
    I. I_CALLBACK_PROGRAM
    II. I_CALLBACK_PF_STATUS_SET
    III. I_CALLBACK_USER_COMMAND
    This function module is used to set the default gui status etc.
    B. REUSE_ALV_BLOCK_LIST_APPEND
    Parameters :
    Export :
    I. is_layout : layout settings for block
    II. it_fieldcat : field catalog
    III. i_tabname : internal table name with output data
    IV. it_events : internal table with all possible events
    Tables :
    i. t_outtab : internal table with output data.
    This function module adds the data to the block.
    Repeat this function for all the different blocks to be displayed one after the other.
    C. REUSE_ALV_BLOCK_LIST_HS_APPEND
    This function module is used for hierarchical sequential blocks.
    D. REUSE_ALV_BLOCK_LIST_DISPLAY
    Parameters : All the parameters are optional.
    This function module display the list with data appended by the above function.
    Here the functions REUSE_ALV_FIELDCATALOG_MERGE, REUSE_ALV_EVENTS_GET, REUSE_ALV_COMMENTARY_WRITE can be used.
    3. Hierarchical reports :
    Hierarchical sequential list output.
    The function module is
    A. REUSE_ALV_HIERSEQ_LIST_DISPLAY
    Parameters:
    I. Export:
    i. I_CALLBACK_PROGRAM
    ii. I_CALLBACK_PF_STATUS_SET
    iii. I_CALLBACK_USER_COMMAND
    iv. IS_LAYOUT
    v. IT_FIELDCAT
    vi. IT_EVENTS
    vii. i_tabname_header : Name of the internal table in the program containing the
    output data of the highest hierarchy level.
    viii. i_tabname_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    ix. is_keyinfo : This structure contains the header and item table field
    names which link the two tables (shared key).
    II. Tables
    i. t_outtab_header : Header table with data to be output
    ii. t_outtab_item : Name of the internal table in the program containing the
    output data of the lowest hierarchy level.
    slis_t_fieldcat_alv : This internal table contains the field attributes. This internal table can be populated automatically by using ‘REUSE_ALV_FIELDCATALOG_MERGE’.
    Important Attributes :
    A. col_pos : position of the column
    B. fieldname : internal fieldname
    C. tabname : internal table name
    D. ref_fieldname : fieldname (dictionary)
    E. ref_tabname : table (dictionary)
    F. key(1) : column with key-color
    G. icon(1) : icon
    H. symbol(1) : symbol
    I. checkbox(1) : checkbox
    J. just(1) : (R)ight (L)eft (C)ent.
    K. do_sum(1) : sum up
    L. no_out(1) : (O)blig.(X)no out
    M. outputlen : output length
    N. seltext_l : long key word
    O. seltext_m : middle key word
    P. seltext_s : short key word
    Q. reptext_ddic : heading (ddic)
    R. ddictxt(1) : (S)hort (M)iddle (L)ong
    S. datatype : datatype
    T. hotspot(1) : hotspot
    some theory regarding alv:
    This table tells ALV which events are processed by the caller by CALLBACK.
    The table of possible events per list type can be initialized using the module REUSE_ALV_EVENTS_GET.
    You can display the names of the constants in the type pools SLIS which represent the individual events using the individual test function in the function module
    REUSE_ALV_EVENT_NAMES_GET. Only events with a form routine name are processed.
    The table structure contains the fields:
    • IT_EVENTS-NAME
    Name of the Callback event.
    Possible Callback events:
    • Action
    USER_COMMAND USING R_UCOMM LIKE SY-UCOMM RS_SELFIELD TYPE SLIS_SELFIELD
    Process actions on the list
    As this is a frequently-used Callback event, the form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_USER_COMMAND.
    PF_STATUS_SET USING RT_EXTAB TYPE SLIS_T_EXTAB
    If a user list status is to be set, it must be done in the form routine assigned to this event. The ALV function codes, which must not be active, are in the Parameter RT_EXTAB. This table must be passed with the SET PF-STATUS command (with inactive user function codes as well, if necessary).
    The STANDARD status of the function group SALV should be used as a template for a user-specific status.
    As this is a frequently-used Callback event, its form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_PF_STATUS_SET.
    ITEM_DATA_EXPAND USING RS_SELFIELD TYPE SLIS_SELFIELD RFLG_ALL TYPE C
    Only relevant for hierarchical-sequential lists using the layout parameter IS_LAYOUT-EXPAND_FIELDNAME of the structure IS_LAYOUT.
    Exit for passing item entries (ITEM table) for a header record which was expanded interactively by the user.
    RS_SELFIELD-TABINDEX contains the header table index for which the item entries are to be put in the global item output table (T_OUTTAB_SLAVE). The Callback is only called if ALV has no items for a header which is to be expanded.
    RFLG_ALL is passed with 'X' if the user shows all items. The application must ensure that entries are not repeated in the item table. RS_SELFIELD is initial in this case.
    CALLER_EXIT USING RS_DATA Is called at the beginning of the function module to make special settings. It is not usually used.
    • List processing events
    IMPORTANT: The application Callback routine must not manipulate the internal output table and/or its header record. This restriction applies to all Callbacks which are called in the list output and run under the 'List processing events'.
    TOP_OF_LIST no USING parameter. Information output at the start of the list
    END_OF_LIST no USING parameter. Information output at the end of the list
    TOP_OF_PAGE no USING parameter
    Equivalent to the list processing TOP-OF-PAGE event
    END_OF_PAGE no USING parameter. Not available for hierarchical-sequential lists.
    Information output at the end of a page. This is only called for printing.
    TOP_OF_COVERPAGE no USING parameter
    The selection information and list status are output together (if they exist) on a separate page by default. See also the documentation of the parameters:
    IS_PRINT-NO_COVERPAGE
    IS_PRINT-NO_PRINT_SELINFOS
    IS_PRINT-NO_PRINT_LISTINFOS
    IS_LAYOUT-GET_SELINFOS
    The user can format the header area of the 'cover page' himself or herself by specifying a Callback routine for this event.
    END_OF_COVERPAGE no USING parameter
    Analogously to TOP_OF_COVERPAGE the user can add other information to the information output by ALV (selection information, list status) at this event.
    FOREIGN_TOP_OF_PAGE no USING parameter
    The Top-of-page event is always processed in ALV and is only passed to the caller via the Callback mechanism. This is still the case if the caller, e.g. by a user action, processes a branch list which was not formatted by ALV (e.g. a popup with additional information about the list record selected and displayed by ALV).
    In this case, top-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event top-of-page still occurs in ALV. When ALV notices a top-of-page which was not caused by an ALV output, the form routine in FOREIGN_TOP_OF_PAGE is called.
    FOREIGN_END_OF_PAGE no USING parameter
    The event end-of-page is always processed in ALV and only passed to the caller via callback. This is still the case, e.g. when the caller processes a details list which was not formatted by ALV (e.g. a popup with further information about selected list records which were displayed by ALV).
    In this case, end-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event end-of-page still occurs in ALV. When ALV notices an end-of-page that was not caused by an ALV output, the form routine in FOREIGN_END_OF_PAGE is called.
    BEFORE_LINE_OUTPUT USING RS_LINEINFO TYPE SLIS_LINEINFO
    Output information before each output line. Should only be used in justified cases because it costs a lot of performance.
    AFTER_LINE_OUTPUT USING RS_LINEINFO TYPE SLIS_LINEINFO
    Output information after each output line. Should only be used in justified cases because it costs a lot of performance.
    • Internal use only
    LIST_MODIFY USING R_TABNAME TYPE SLIS_TABNAME
    R_INDEX LIKE SY-TABIX
    R_INDEX_ITEM LIKE SY-TABIX
    R_INDEX_SUM LIKE SY-TABIX
    • IT_EVENTS-FORM
    Name of the form routine which should be called in the calling program at the event.
    Field_catalog:
    Field catalog with field descriptions
    2.7.1. Description
    Field catalog containing descriptions of the list output fields (usually a subset of the internal output table fields). A field catalog is required for every ALV list output.
    The field catalog for the output table is built-up in the caller's coding. The build-up can be completely or partially automated by calling the REUSE_ALV_FIELDCATALOG_MERGE module
    See also the documentation of the function module REUSE_ALV_FIELDCATALOG_MERGE.
    The minimal field catalog is documented under 'default'. The caller can use the other optional parameters to assign output attributes to a field which differ from the default.
    A field catalog need not be built-up and passed explicitly only under the following conditions:
    • The internal table to be output has the same structure as a Data Dictionary structure which is referred to in the internal table declaration using LIKE or INCLUDE STRUCTURE.
    • all fields in this structure are to be output
    • the structure name is passed to ALV in the parameter I_STRUCTURE_NAME.
    See also the documentation of the IMPORTING paramter I_STRUCTURE_NAME.
    Positioning
    • row_pos (row position)
    value set: 0, 1 - 3
    Only relevant if the list output is to be multi-line (two or three lines) by default.
    A multi-line list can also be defined by the user interactively if the default list is one-line.
    The parameter specifies the relative output line of the column in a multi-line list.
    • col_pos (column position)
    value set: 0, 1 - 60
    only relevant when the default relative column positions differ from the field catalog field sequence. The parameter specifies the relative column position of the field in the list output. The column order can be changed interactively by the user. If this parameter is initial for all field catalog entries, columns appear in the field catalog field sequence.
    Identification
    • fieldname (field name)
    value set: internal output table field name (required parameter)
    Name of the internal output table field which is described by this field catalog entry
    • tabname (internal output table)
    value set: SPACE, internal output table name
    This parameter is used in 'manual' field catalog build-up only for hierarchical-sequential lists.
    Name of the internal output table which contains the field FIELDCAT-FIELDNAME.
    Data Dictionary reference
    • ref_fieldname (reference field name)
    value set: SPACE, Data Dictionary field name
    Name of the Data Dictionary field referred to.
    This parameter is only used when the internal output table field described by the current field catalog entry has a reference to the Data Dictionary (not a program field), and the field name in the internal output table is different from the name of the field in the Data Dictionary. If the field names are identical, naming the Data Dictionary structure or table in the FIELDCAT-REF_TABNAME parameter is sufficient.
    • ref_tabname (reference table/structure field name)
    value set: SPACE, name of a Data Dictionary structure or table
    Structure or table name of the referred Data Dictionary field.
    This parameter is only used when the internal output table field described by the current field catalog entry has a Data Dictionary reference (not a program field).
    Reference to fields with currency/measurement unit
    Each internal output table sum or quantity field whose decimal places are to be formatted appropriately for the unit in the list must follow the convention:
    • the field is of data type QUAN or CURR (internal type P) (the field must really have this physical data type. Overwriting the physical data type with the parameter FIELDCAT-DATATYPE has no effect)
    • There is a field in the internal output table which contains the associated unit.
    • There is also an entry in the field catalog for the unit field.
    (If the unit is not to appear as a column in the list, and cannot be interactively displayed as a column, e.g. because it is always unambiguous and is therefore explicitly output by the caller in the list header, the field catalog units field entry can take the parameter FIELDCAT-TECH = 'X'.
    The association of a value field to a unit affects the output as follows:
    • appropriate decimal places display for the unit
    • an initialized field with a link to a non-initial unit is output as '0' for the unit (if FIELDCAT-NO_ZERO is initial). When this field is summed, this unit affects whether the units are homogeneous.
    • an initialized field with a link to an initial unit is output as SPACE. When this field is summed, the unit SPACE does not affect the homogeneity of the units.
    • When non-initial fields with an initial unit are summed, the unit SPACE is considered to be a unit.
    Link to currency unit
    • cfieldname (currency unit field name)
    value set: SPACE, output table field name
    Only relevant for amount columns with associated unit.
    Name of the internal output table field containing the currency unit associated with the amount field FIELDCAT-FIELDNAME. The field in FIELDCAT-CFIELDNAME must have its own field catalog entry.
    • ctabname (internal currency unit field output table)
    value set: SPACE, output table field name
    only relevant for hierarchical-sequential lists
    Name of the internal output table containing the FIELDCAT-CFIELDNAME field.
    Link to measurement unit
    • qfieldname (measurement unit field name)
    value set: SPACE, output table field name
    only relevant for quantity columns with unit link.
    Name of the internal output table field containing the measurement unit associated with the quantity field FIELDCAT-FIELDNAME.
    The field in FIELDCAT-QFIELDNAME must have its own field catalog entry.
    • qtabname (internal measurement unit field output table)
    value set: SPACE, output table field name
    only relevant for hierarchical-sequential lists
    Name of the internal output table containing the FIELDCAT-QFIELDNAME field.
    Column output options
    • outputlen (column width)
    value set: 0 (initial), n
    For fields with a Data Dictionary link this parameter can be left initial.
    For fields without a Data Dictionary link (program field) the parameter must be given the value of the desired field list output length (column width).
    initial = column width is the output length of the referred Data Dictionary field (domain).
    n = column width is n characters
    • key (key column)
    value set: SPACE, 'X' 'X' = kex field (key field output in color)
    Key fields can not be interactively hidden. Parameter FIELDCAT-NO_OUT must be left initial.
    For exceptions see the documentation of the FIELDCAT-KEY_SEL parameter.
    • key_sel (hideable key column)
    value set: SPACE, 'X'
    only relevant when FIELDCAT-KEY = 'X'
    Key field which can be hidden interactively.
    The key column sequence cannot be changed interactively by the user.
    The output is controlled by the FIELDCAT-NO_OUT parameter analogously to non-key fields.
    • no_out (field in field list)
    value set: SPACE, 'X' 'X' = field is not displayed in the current list.
    The user can interactively choose the field for output from the field list.
    The user can display the contents of these fields at line level using the 'Detail' function.
    See also the 'Detail screen' documentation of the parameter IS_LAYOUT.
    • tech (technical field)
    value set: SPACE, 'X' 'X' = technical field
    Field cannot be output in the list and cannot be displayed interactively.
    Field can only be used in the field catalog (not in IT_SORT, ...).
    • emphasize (highlight columns in color)
    value set: SPACE, 'X' or 'Cxyz' (x:'1'-'9'; y,z: '0'=off '1'=on)
    'X' = column is colored with the default column highlight color.
    'Cxyz' = column is colored with a coded color:
    • C: Color (coding must begin with C)
    • x: color number
    • y: bold
    • z: inverse
    • hotspot (column as hotspot)
    value set: SPACE, 'X'
    'X' = column cells are output as hotspots
    • fix_column (fix column)
    value set: SPACE, 'X'
    Not relevant for block lists (output of several lists consecutively)
    'X' = column fixed (does not scroll horizontally)
    All columns to be fixed must have this flag, starting from the left. If a column without this flag is output, only the columns to the left of this column are fixed. The user can change the column fixing interactively. See also the documentation of the Layout parameter
    IS_LAYOUT-NO_KEYFIX of the IMPORTING paramter IS_LAYOUT.
    • do_sum (sum over column)
    value set: SPACE, 'X' 'X' = a sum is to be calculated over this internal output table field.
    This function can also be called by the user interactively.
    • no_sum (sums forbidden)
    value set: SPACE, 'X' 'X' = no sum can be calculated over this field, although the data type of the field would allow summing.
    • input (column ready for input)
    Function not available
    Format column contents
    • icon
    value set: SPACE, 'X' 'X' = column contents to be output as an icon.
    The caller must consider the printability of icons.
    • symbol
    value set: SPACE, 'X' 'X' = column contents are to be output as a symbol.
    The internal output table column must be a valid symbol character.
    The caller must consider the printability of symbols.
    Symbols can usually be printed, but may not always be output correctly, depending on the printer configuration.
    • just (justification)
    value set: SPACE, 'R', 'L', 'C'
    Only relevant for fields of data type CHAR or NUMC
    ' ' = default justification for this data type
    'R' = right-justified output
    'L' = left-justified output
    'C' = centered output
    The justification of the column header always follows the justification of the columns. Independent justification of the column neader is not possible.
    • lzero (leading zeros)
    value set: SPACE, 'X'
    Only relevant for fields of data type NUMC
    ALV outputs NUMC fields right-justified without leading zeros by default.
    'X' = output with leading zeros
    Note: If a NUMC field is output left-justified or centered by FIELDCAT-JUST, leading zeros are output. If the output of leading zeros is suppressed by a Data Dictionary reference ALPHA conversion exit, the output is always left-justified.
    • no_sign (no +/- sign) Only relevant for value fields
    value set: SPACE, 'X' 'X' = value output without +/ sign
    • no_zero (suppress zeros) Only relevant for value fields
    value set: SPACE, 'X' 'X' = suppress zeros
    • edit_mask (field formatting)
    value set: SPACE, template
    template = see documentation of WRITE formatting option USING EDIT MASK template
    The output conversion conv can be made by template = '== conv'.
    Texts
    The following text parameters should be specified for program fields without a Data Dictionary reference. The texts are taken from the Data Dictionary for fields with a Data Dictionary reference. If this is not desired, the text parameters can also be specified. The Data Dictionary texts are then ignored. If the user changes the column width interactively, the column header text with the appropriate length is always used. The interactive function 'Optimize column width' takes account of both the field contents and the column headers: if all field contents are shorter than the shortest column header, the column width depends on the column header.
    The 'long field label' is also used in display variant definition, sort, etc. popups.
    • seltext_l (long field label)
    • seltext_m (medium field label)
    • seltext_s (short field label)
    • reptext_ddic (header)
    analogous to the Data element maintenance 'Header'
    The specified text is not necessarily output in the list, an optimum among all texts is sought.
    • ddictxt (specify text)
    value set: SPACE, 'L', 'M', 'S'
    You can specify with values 'L', 'M', and 'S', the keyword that should always be used as column header. If the column width changes, no attempt is made in this case to find an appropriate header for the new output width.
    Parameters for program fields without Data Dictionary reference
    see also 'Text' parameters
    • datatype (data type)
    value set: SPACE, Data Dictionary data type (CHAR, NUMC,...)
    Only relevant for fields without Data Dictionary reference
    Program field data type
    • ddic_outputlen (external output length)
    value set: 0 (initial), n
    Only relevant for fields without Data Dictionary reference whose output is nevertheless to be modified by a conversion exit.
    Prerequisites:
    • FIELDCAT-EDIT_MASK = '==conv'
    see also the documentation of the parameter FIELDCAT-EDIT_MASK
    • FIELDCAT-INTLEN = n
    see also the documentation of the parameter FIELDCAT-INTLEN
    n = external format field output length
    The column width FIELDCAT-OUTPUTLEN need not be the same as the external format output length (FIELDCAT-DDIC_OUTPUTLEN).
    • intlen (internal output length)
    value set: 0 (initial), n
    Only relevant for fields without Data Dictionary reference whose output is nevertheless to be modified by a conversion exit.
    Prerequisites:
    • FIELDCAT-EDIT_MASK = '==conv'
    see also the documentation of the parameter FIELDCAT-EDIT_MASK
    • FIELDCAT-DDIC_OUTPUTLEN = n
    see also the documentation of the parameter FIELDCAT-DDIC_OUTPUTLEN
    n = internal format field output length
    • rollname (data element)
    value set: SPACE, Data Dictionary data element name
    F1 help can be provided for a program field without a Data Dictionary reference, or F1 help which differs from the Data Dictionary help can be provided for a field with a Data Dictionary reference, using this parameter.
    When F1 help is called for this field, the documentation of the specified data element is displayed.
    If the FIELDCAT-ROLLNAME is initial for fields with a Data Dictionary reference, the documentation of the data element of the referred Data Dictionary field is output.
    Others
    • sp_group (field group key)
    value set: SPACE, CHAR(1)
    Field group key.
    Keys are assigned to group names in the IT_SPECIAL_GROUPS parameter (see also the documentation of the parameter IT_SPECIAL_GROUPS).
    When such an assignment is made in the field catalog and in IT_SPECIAL_GROUPS, the fields are grouped correspondingly in the display variant popup.
    • reprep (Report/Report interface selection criterion)
    value set: SPACE, 'X'
    Prerequisites:
    • The system contains the Report/Report interface (function group RSTI, table TRSTI)
    • Parameter LAYOUT-REPREP = 'X'
    (see also the documentation of the parameter LAYOUT-REPREP of the IMPORTING parameter IS_LAYOUT )
    'X' = When the Report/Report interface is called, the value of this field is passed in the selected interface start record as a selection criterion.
    2.7.2. Default
    • The following entries are usually sufficient for internal table fields with a reference to a field defined in the Data Dictionary :
    • fieldname
    • ref_tabname
    Notes:
    ALV gets the remaining information from the Data Dictionary.
    If no relative column position (COL_POS) is specified, the fields are output in the list in the order in which they were added to the field catalog.
    REF_FIELDNAME need only be specifid when the name of the internal table field differs from the name of the referred Data Dictionary field.
    Information which is explicitly entered in the field catalog is not overwritten by information from the Data Dictionary.
    Priority rule:
    Entries in the field catalog have priority over differing entries in the Data Dictionary.
    • The following entries are usually sufficient for internal table fields without a reference to the Data Dictionary (program fields):
    • fieldname
    • outputlen
    • datatype
    • seltext_s
    • seltext_m
    • seltext_l
    Notes:
    F1 help can be provided for program fields by assigning a data element to the parameter ROLLNAME.
    If the parameters SELTEXT_S, SELTEXT_M, SELTEXT_L, and REPTEXT_DDIC contain appropriate field labels, the program field column headers are also adjusted appropriately when the column width changes
    sites :
    http://www.sapdevelopment.co.uk/reporting/alv/alv_variousfcat.htm
    <b>plese reward if useful </b>
    Message was edited by:
            sunil kairam

  • What SAP modules are required for insuance sector

    what SAP modules are required for insuance sector

    Hi,
    Following authorizations are required to be able to use all the functions of Support Package Manager:
    S_CTS_ADMI
    S_TRANSPRT
    Additional objects required and which can be used to restrict further the functionality are:
    S_C_FUNCT
    S_CTS_ADMI
    S_DATASET
    S_GUI
    S_RFC
    As available in the SAP help,standard SAP S_A.SYSTEM contains all necessary access for importing support packages.
    Regards,
    Nagendran

  • How SCXI modules are multiplexed into one Channel of the DAQ card?

    Hi all,
    I am Sirisha from Hyderabad.
    I am a new to NI hardware.
    take the below mentioned senario.
    Suppose i am using SCXI-1000 chassis with SCXI-1520 and 3 SCXI-1102 modules and PCI-6070E DAQ card.
    now i know that if i connect the DAQ card to the SCXI chassis through sh-6868 cable and 1349 adapter, all channels of SCXI modules are multiplxed into the 0th channel of DAQ card.
    Here i want the detailed explanation of theory of multiplexion on how all the scxi channels go to 0th channel of DAQ card
    Thanks in advance
    regards
    Preetam

    Sirisha,
    Thank you for contacting National Instruments.
    Here is a KnowledgeBase article entitled "How Are SCXI Channels Multiplexed While Having Other Inputs On The DAQ Card?"
    There is a little more specific information about multiplexed mode here.
    Michael P
    National Instruments

  • What modules are included with my license

    Hi,
    I am using ECC 6.0. I would like to know what modules are included with my license. For eg. SD, MM, FICO and whether we also have CRM or EP with our package? How do we find that out? Please help.
    Cheers

    Call you SAP Account Manager