Pwd change option in Hyperion 9.3.1

Hi All,
i created a user in Shared services and exported to WebAnalysis till now this is fine....
is there any option for user to change Password
Vijay.....

Hi Vijay,
There is no such option in Web analysis Studio to allow user to change his password. But he is accessing reports developed in web analysis studio from workspace then there is an option in workspace under link 'Preference' to allow a user to change his password.
Hope it will help you.
Atul K,

Similar Messages

  • How to track changes in a hyperion application for SOX control?

    Hello all,
    We have been working on identifying the best way on how to track changes in a hyperion application in regards to the SOX control.
    The following areas have been identified as the main areas of an application where the changes are to be tracked:
    Monthly data load from ODI
    Calculation of data
    Metadats change
    Formula edit
    Changes to reports
    Changes to security
    Can anybody please suggest the best ways to do this? Has anyone experienced this issue before?
    Somebody suggested that there is hyperion auditing available.
    Is there any other software that is available that can do this or just documenting the changes would be the best option?
    Please suggest. Toyr response would be appreciated.
    Thanks.

    Shared Services allows the auditing of provisioning and life-cycle management activities to track changes to security objects and the artifacts that are exported or imported using Lifecycle Management Utility.
    For Shared Services auditing, refer Page 129 of http://download.oracle.com/docs/cd/E12825_01/epm.111/epm_security.pdf
    Planning Administrators can select aspects of the application for change tracking. For example, you can track changes to metadata, such as when users change a member property or add a currency. You can also track changes in data forms, business rules, workflow, users, access permissions, and so on.
    For Planning auditing, refer Page 56 of http://download.oracle.com/docs/cd/E12825_01/epm.111/hp_admin.pdf
    HTH-
    Jasmine.

  • Fast change option in Sales order-Additiinal field required

    Dear al
    We want to add schedule line category field in Fast change option in Sales order as we have a requriment of changing schedule line category for more than 20 lines in sales order...After sales order is created ,we go and change the schedule line category ...
    Tried using MASS transaction but this doesn't have Schedule line category field.(VBEP table)
    Table name-VBEP
    Field name-ETTYP
    In VA05 also there is no option to change schedule line category mass update...
    Should we have to do in screen painter only for adding this field...
    Please confirm
    Regards
    Sudha

    Hi Sudha
    It would be better if you tell with which Ztable you have updated the data and how. It would be better if you share what you have done
    Regards
    Srinath

  • "Open in Smart View" option. Hyperion Planning version 11.1.1.3

    Failure to download planning form to Smart View using the "Open in Smart View" option. Hyperion Planning version 11.1.1.3. Error message "Web launch operation has been cancelled.
    Your feedback is appreciated.

    I understand you are on 11.1.1.3.
    However, this is documented in the Known Issues section of the Smart View 11.1.2.1 readme and could be worth a try: 
    When you try to open a Planning web form in Smart View through Workspace, you may get this error: “Web launch operation has been cancelled.” This happens if Essbase has not been added as a server in Shared Connections. Workaround: Open the Smart View Panel in Smart View and add an Essbase server as described in the online help or "Adding Essbase Servers" in chapter 2 of the Smart View User's Guide. 
    HTH-
    Jasmine.

  • Changing option in function module

    sir,
      plz explain the role or importance of changing option in function module SE37

    hi check this example it had the usage of the changing option..
    here the using will input the value to the perform and do some prosses and output some value..
    PERNR               TYPE P0001-PERNR                           Personnel Number                  
    PLANS               TYPE P0001-PLANS                           Position                          
    ORGEH               TYPE P0001-ORGEH                           Organizational Unit               
    DATE                TYPE SY-DATUM       SY-DATUM               Date and time, current (applic    
    PLVAR               TYPE PLOG-PLVAR     '01'                   Plan Version                      
    ISTAT               TYPE PLOG-ISTAT     '1'                    Planning Status                   
    MANAGER     TYPE     ZHMSS_MANAGER     Structure for manager for MSS
    NO_PERNR_PLANS_ORGEH_SPEC     No pernr, position or org unit specified
    NO_EXIST_PLANS                Position does not exist                 
    INVALID_PLANS                 Position invalid                        
    NO_EXIST_ORGEH                Org unit does not exist                 
    NO_EXIST_PERNR                Personnel number does not exist         
    function z_get_orgunit_manager_info.
    ""Local interface:
    *"  IMPORTING
    *"     REFERENCE(PERNR) TYPE  P0001-PERNR OPTIONAL
    *"     REFERENCE(PLANS) TYPE  P0001-PLANS OPTIONAL
    *"     REFERENCE(ORGEH) TYPE  P0001-ORGEH OPTIONAL
    *"     REFERENCE(DATE) TYPE  SY-DATUM DEFAULT SY-DATUM
    *"     REFERENCE(PLVAR) TYPE  PLOG-PLVAR DEFAULT '01'
    *"     REFERENCE(ISTAT) TYPE  PLOG-ISTAT DEFAULT '1'
    *"  EXPORTING
    *"     REFERENCE(MANAGER) TYPE  ZHMSS_MANAGER
    *"  EXCEPTIONS
    *"      NO_PERNR_PLANS_ORGEH_SPEC
    *"      NO_EXIST_PLANS
    *"      INVALID_PLANS
    *"      NO_EXIST_ORGEH
    *"      NO_EXIST_PERNR
      if pernr is initial and
         plans is initial and
         orgeh is initial.
        raise no_pernr_plans_orgeh_spec.
      endif."pernr is initial and
      if not pernr is initial.
        if pernr cn '0123456789'.
          exit.
        endif.
    *-- See if pernr exists
        call function 'P_EMPLOYEE_CHECKEXISTENCE'
             exporting
                  object_id          = pernr
                  date               = date
             exceptions
                  employee_not_found = 01.
        if sy-subrc ne 0.
          raise no_exist_pernr.
          exit.
        endif.
    *-- Obtain pernr position
        call function 'HR_READ_INFOTYPE'
             exporting
                  pernr           = pernr
                  infty           = c_infty_0001
                  begda           = date
                  endda           = date
             importing
                  subrc           = g_retcd
             tables
                  infty_tab       = i0001
             exceptions
                  infty_not_found = 01
                  others          = 02.
        if sy-subrc eq 0.
          describe table i0001 lines g_lines.
          if g_lines > 0.
            read table i0001 index 1.
    *-- Got position now find org unit
            perform zf_proc_get_om_objects tables i_objects
                                           using c_otype_position
                                                 i0001-plans
                                                 plvar
                                                 c_rsign_a
                                                 c_relat_003
                                                 istat
                                                 date
                                                 date
                                                 c_otype_orgunit
                                        changing g_retcd.
            if g_retcd eq 0.
              read table i_objects index 1.
              g_orgeh = i_objects-sobid(8).
            endif. "g_retcd eq 0.
          endif. "g_lines > 0. for i0001
        endif.  "sy-subrc eq 0 hr_read_infotype
      elseif not plans is initial.
        if plans co '9' or
           plans co '0'.
          raise invalid_plans.
          exit.
        endif.
        call function 'RH_READ_OBJECT'
             exporting
                  plvar     = plvar
                  otype     = c_otype_position
                  objid     = plans
                  istat     = istat
                  begda     = date
                  endda     = date
                  langu     = sy-langu
             exceptions
                  not_found = 1
                  others    = 2.
        if sy-subrc <> 0.
          raise no_exist_plans.
          exit.
        endif.
    *-- Find org unit
        perform zf_proc_get_om_objects tables i_objects
                                       using c_otype_position
                                             plans
                                             plvar
                                             c_rsign_a
                                             c_relat_003
                                             istat
                                             date
                                             date
                                             c_otype_orgunit
                                    changing g_retcd.
        if g_retcd eq 0.
          read table i_objects index 1.
          g_orgeh = i_objects-sobid(8).
        endif."g_retcd eq 0.
      elseif not orgeh is initial.
        call function 'RH_READ_OBJECT'
             exporting
                  plvar     = plvar
                  otype     = c_otype_orgunit
                  objid     = orgeh
                  istat     = istat
                  begda     = date
                  endda     = date
                  langu     = sy-langu
                  CHECK_STRU_AUTH   = space              "ASikaria, 10/15
             exceptions
                  not_found = 1
                  others    = 2.
        if sy-subrc <> 0.
          raise no_exist_orgeh.
          exit.
        endif.
        g_orgeh = orgeh.
      endif. "not pernr is initial.
      if not g_orgeh is initial.
        manager-orgeh = g_orgeh.
    *-- Got org unit now find manager
        perform zf_proc_get_om_objects tables i_objects
                                       using c_otype_orgunit
                                             manager-orgeh
                                             plvar
                                             c_rsign_b
                                             c_relat_012
                                             istat
                                             date
                                             date
                                             c_otype_position
                                    changing g_retcd.
        if g_retcd eq 0.
          read table i_objects index 1.
          if sy-subrc eq 0.
            manager-plans = i_objects-sobid.
            call function 'Z_GET_POSITION_HOLDER'
                 exporting
                      plans              = manager-plans
                      plvar              = plvar
                      istat              = istat
                      date               = date
                 importing
                      pernr              = manager-pernr
                 exceptions
                      position_not_exist = 1
                      position_invalid   = 2
                      others             = 3.
            if sy-subrc <> 0.
              clear: manager-pernr.
            endif.
            if not manager-pernr is initial.
    *- BOC RTDK902962
    *-- Obtained formatted name
              clear: i0001.
              refresh: i0001.
              call function 'HR_READ_INFOTYPE'
                   exporting
                        pernr           = manager-pernr
                        infty           = c_infty_0001
                        begda           = date
                        endda           = date
                   importing
                        subrc           = g_retcd
                   tables
                        infty_tab       = i0001
                   exceptions
                        infty_not_found = 1
                        others          = 2.
              if sy-subrc eq 0.
                read table i0001 index 1.
                if sy-subrc eq 0.
                  manager-ename = i0001-ename.
                endif.
              endif.
    *- EOC RTDK902962
    *-- Obtain pernr information
    *- Get 0002 data
              clear: i0002.
              refresh: i0002.
              call function 'HR_READ_INFOTYPE'
                   exporting
                        pernr           = manager-pernr
                        infty           = c_infty_0002
                        begda           = date
                        endda           = date
                   importing
                        subrc           = g_retcd
                   tables
                        infty_tab       = i0002
                   exceptions
                        infty_not_found = 1
                        others          = 2.
              if sy-subrc eq 0.
                read table i0002 index 1.
                if sy-subrc eq 0.
                  manager-inits = i0002-inits.
                  manager-vorna = i0002-vorna.
                  manager-nachn = i0002-nachn.
                  manager-midnm = i0002-midnm.
                endif.
              endif.
    *- Get 0105 data
              clear: i0105.
              refresh: i0105.
              call function 'HR_READ_INFOTYPE'
                   exporting
                        pernr           = manager-pernr
                        infty           = c_infty_0105
                        begda           = date
                        endda           = date
                   importing
                        subrc           = g_retcd
                   tables
                        infty_tab       = i0105
                   exceptions
                        infty_not_found = 1
                        others          = 2.
              if sy-subrc eq 0.
                describe table i0105 lines g_lines.
                if g_lines > 0.
    *- SAP usrid
                  loop at i0105 where subty = c_0105_usrid_subty.
                    manager-usrid = i0105-usrid.
                  endloop.
    *- Email address
    *// not sure where email is going to be stored but assume it is subtype
    *// 0010
                  loop at i0105 where subty = c_0105_email_subty.
                    manager-email = i0105-usrid_long.
                  endloop.
                endif. "g_lines > 0
              endif."sy-subrc eq 0.
            endif. "not manager-pernr is initial.
          endif. "sy-subrc eq 0.
        endif."g_retcd eq 0.
      endif. "not g_orgeh is initial.
    endfunction.
    zposition holder
    PLANS     TYPE     PLOG-OBJID                               Object ID
    PLVAR     TYPE     PLOG-PLVAR     '01'     Plan Version
    ISTAT     TYPE     PLOG-ISTAT     '1'     Planning Status
    DATE     TYPE     SY-DATUM     SY-DATUM     Date and time, current (application server) date
    PERNR               TYPE      P0001-PERNR                 Personnel Number                
    POSITION_NOT_EXIST            Position does not exist                 
    POSITION_INVALID              Invalid position                        
    function z_get_position_holder.
    ""Local interface:
    *"  IMPORTING
    *"     REFERENCE(PLANS) TYPE  PLOG-OBJID
    *"     REFERENCE(PLVAR) TYPE  PLOG-PLVAR DEFAULT '01'
    *"     REFERENCE(ISTAT) TYPE  PLOG-ISTAT DEFAULT '1'
    *"     REFERENCE(DATE) TYPE  SY-DATUM DEFAULT SY-DATUM
    *"  EXPORTING
    *"     REFERENCE(PERNR) TYPE  P0001-PERNR
    *"  EXCEPTIONS
    *"      POSITION_NOT_EXIST
    *"      POSITION_INVALID
      if plans cn '0123456789'.
        raise position_invalid.
      endif."plans cn '0123456789'.
      if plans co '9'.  "default position
        exit.
      endif.
      call function 'RH_READ_OBJECT'
           exporting
                plvar     = plvar
                otype     = c_otype_position
                objid     = plans
                begda     = date
                endda     = date
           exceptions
                not_found = 01
                others    = 02.
      if sy-subrc ne 0.
        raise position_not_exist.
      else.
        perform zf_proc_get_om_objects tables i_objects
                                       using c_otype_position
                                             plans
                                             plvar
                                             c_rsign_a
                                             c_relat_008
                                             istat
                                             date
                                             date
                                             c_otype_pernr
                                    changing g_retcd.
        if g_retcd eq 0.
          sort i_objects by begda descending. "get earliest rec
          read table i_objects index 1.
          if sy-subrc eq 0.
            pernr = i_objects-sobid(8).
          endif.
        endif. "g_retcd eq 0.
      endif. "sy-subrc ne 0.
    endfunction.
    regards,
    venkat

  • Remote content bar does not appear for some emails with images specifically daily Twitter updates. Changing options to allow all remote content has no effect

    The broken image symbol appears in place of the images but associated web links do work ok.
    Changing options to allow all remote content has no effect. Senders' addresses are in my address book and on the exceptions list.
    Some emails (from other sources) load perfectly. Using Kaspersky Internet Security 2015 on Windows 8.1. Thunderbird 31.4.0
    Any help appreciated.

    You only need to post a URL to your web site. We can see your code in Browser.
    So, your page looks OK to me in Firefox, but when I tried to check it in IE, it choked my browser and closed it.
    You have quite a few code validation errors - no document type declaration, etc... Start by fixing these reported errors.
    http://validator.w3.org/check?verbose=1&uri=http%3A%2F%2Fntp.neuroscience.wisc.edu%2F
    Nancy O.
    Alt-Web Design & Publishing
    Web | Graphics | Print | Media  Specialists
    www.alt-web.com/
    www.twitter.com/altweb
    www.alt-web.blogspot.com

  • Client Change options in SCC4 (SAP ECC 6.0)

    Hi,
    Our SAP Development system SCC4 settings are as mentioned below:
    1.Changes and transports for client-specific objects : Automatic recording of changes
    2.Cross-client object changes : Changes to repository and cross-client customizing allowed
    3.Protection regarding client copy/comparison,: Protection level 1: No overwriting
    Please suggest me , above mentioned settings are correct?
    Development users are complainting that they are getting error "SAP System has status 'not modifiable'", Can anyone please help me how to solve this problem?
    Thanks in advance!!!!
    Regards
    Veera

    SE06
    @ clieck on
    system change option
    @ go to EDIT
    software Comonents Modifiable
    Name sapces Modifiable
    own name space Modifiable
    but if it is PRD system then i will Not suggest for client Modifiable..
    Best of Luck
    Thanks
    Mithun Das

  • The system and namespace change option

    Hi Experts,
    I want to integrate a certain SAP Source System within RSA1. After submitting the correct settings for Background User and RFC connection the process leads me to the Source System where I logon with an User which has authorizations in SM59. From there on (the RFC Connection backwards is already defined) I got asked whether I want to user/check/cancel this existing RFC Connection. I click on use, wait for a while and then the error (please see below) appears.
    When proceeding with the steps mentioned in the error message (transaction SE03, Administration node, ...) I cannot find any IDOC Object ZSSA009. I think maybe it's related to some software component or somenthing like that which should be set as "modifiable" but I don't know which....
    Any Ideas on this?
    Many thanks in advance.
    Best regards
    Tobias
    Error Message:
    Message no. TO128
    Diagnosis
    The system and namespace change option set for this SAP System does not allow any changes to be made to object IDOC ZSSA009.
    System Response
    Editing is terminated, the object can only be displayed.
    Procedure
    If you want to edit the object IDOC ZSSA009 in this SAP System, have your system administator set the SAP System to "modifiable" for this object.
    This can affect the modifiability of the namespace &1 or the namespaces that correspond to the pattern &1, as well as the global setting of the system change option.
    The system change option is set using the Transport Organizer tools (Transaction SE03). Expand the Administration node and execute the program Set system change option. The options are described there.

    HI,
    Attached link may help you in configuring the source system.
    http://www.sdn.sap.com/irj/scn/index?rid=/library/uuid/908836c3-7f97-2b10-4cb8-e6790361c152
    Thanks,
    Arun

  • New field in ME22n - Fast change option

    Hi Experts,
    I have a requirment to add new field (SLFDT - Statistical delivery date)  in ME22N fast change option.Since the customer don't want to change the standard structures ,I have created append structure for MEPOITEM and MEGUI_MASSCH_ALLOWED_FIELDS. But the new field doen't display in the output, even it doesn't come in debugging mode.
    I have added this field in debugging mode in both structures , at that time this field displays in fast change list.Kindly suggest me on this.
    Also I am not able to find any relevent sap note for this scenario.
    Regards,
    Sreeja

    Hello ,
    Good News on fast change layout .
    i am able to add new fields on the layout and working .
    we have to append structure with new fields in MEGUI_MASSCH_ALLOWED_FIELDS and MEPOITEM.
    after that we have to reset the buffer .
    regards,
    Reddy

  • Software components can keep modifiable in bw 3.5 system change options

    hello experts,
    can we keep software components modifiable in bw 3.5 production in system change option (se06)
    it very urgent

    Hi
    Transaction SE06 - Processing After Installation of the CTO
    Transaction SE06 has to be executed once in every newly installed R/3 System. This applies to an R/3 standard installation as well as the installation of a copy of an existing R/3 system.
    Transaction SE06 provides the following functions for processing after installation:
    Generating basic settings of the Change and Transport Organizer Closing other requests and tasks  Setting the system change option
    Meaning of the system name The system name (SID) is defined during the installation with R3setup and cannot be changed subsequently.
    When you choose names, make sure that there are no naming conflicts with existing systems. Under no circumstances may two systems within an SAP system group have the same name.
    The installation type of the R/3 System is specified in the initial screen:
    R/3 standard installation
    The R/3 System was installed from the SAP CD using R3setup. It is assumed that the system is running on a correct, delivered version of the R/3 System. No adjustments based on corrections or repairs have been made.
    If you set up an R/3 System that originated from a database copy using this option, problems could arise when you upgrade or modify objects with the Change and Transport Organizer.
    Database copy or database migration
    The R/3 System was created on the basis of a copy. R3setup provides utilities to do this. The R/3 System needs to be assigned a new and independent role within the SAP system group or outside of it.
    Before you connect the new R/3 System to the SAP system group, you have to give it a name that has not yet been used in the group.
    You should avoid using a previously used system name as this could cause serious complications and may also lead to the loss of information.
    If you have installed your SAP System as a copy of an existing SAP System then you must configure the CTS after installation.
    In SAP Systems installed with R3setup from the SAP CD the basic settings for the CTS are generated during the configuration of the  Transport Management System. You do not need to perform any processing after installation.
    Transaction SE06 provides the following functions for processing after installation:
    Generating basic settings of the Change and Transport System
    Setting the system change option
    Closing foreign requests and tasks
    You must specify the installation type of the SAP System on the initial screen:
    Standard installation
    The SAP System was installed from the SAP CD using R3setup. It is assumed that the SAP System is running as a correct, delivered version. No adjustments based on corrections or repairs have been made.
    If you set up an SAP System that originated from a database copy using this option, problems could arise when you upgrade the system or modify objects with the Transport Organizer.
    Database copy or database migration
    The SAP System was created on the basis of a copy. R3setup provides utilities to do this. The SAP System needs to be assigned a new and independent role within the SAP system group or outside of it.
    Before you connect the new SAP System to the SAP system group, you have to give it a name that has not yet been used in the group.
    Do not use an existing system name since this could cause serious conflicts and may lead to the loss of data.

  • SE03 / SE06 System Change Option Scope

    Hi All,
    We are creating a source system from R/3 to BW in some specify step we need to change the System Change Option of the sistem in a particular client (SE06 -> System Change Option -> No Modifiable to Modifiable and Modifiable to No Modifiable).
    My question is: This changes are Cross Client?
    Or only apply to the specify client where you are logged?
    Best Regards,
    Erick Ilarraza

    On their own, Global and Compenent specific change options are not client dependent as they are not related to the logical system of the ABAP user nor the master and transaction data (tables with field MANDT as key).
    Personally, I think of it as a "call stack" of checks on whether and what you can modify. Perhaps "System Change Update-ability" would have been a better label, but that is not good English.
    As the stack is released for a user in a client (a logical program system), the system determines what can be updated at different levels of the stack as it unfolds, a bit like a spring. At the top there is SE06. At the bottom of the spring there are individual authority-checks which are system, client, program flow and context, and user access dependent.
    Depending on where in the stack you release the spring from and how you got there, your user can update parts of the stack. Often the term "logical systems" is used in connection with the client (SCC4 client), but also many others such as workflow etc.
    => If the user can pass authority-checks for access at the bottom of the stack (S_DEVELOP is the key control here), then they can also change that which the top of the stack was designed to control. If you can debug, then there is nothing which will stand in your way.
    > My question is: This changes are Cross Client?
    It depends. You still need to control access via authorizations within the client to secure access to the whole system.
    Cheers,
    Julius

  • Publishing Error, and I have tried the Publish Site Changes option

    I tried to update my website for the first time since upgrading and couldn't. I have tried the "Publish Site Changes" option as well as publishing the entire site, but am getting this error message:
    An error occurred while publishing file “/private/var/folders/7R/7Ry8Tbdf2RW72E8ZQJxeU++TI/TemporaryItems/com.apple.iWeb636_TEMP_255615036_7/sites/Site/Musashino_Monday_4/Musashino_Monday_4files/Simps CloseUp.png”. Try publishing again later.
    This has been going on for a couple of days...any idea what gives?

    Hi,
    Error 7 is "No Data for 10 Secs" and is related to bandwidth issues.
    It generally means the bandwidth dropped as you made the call.
    This can be due to a number of factors.
    As it is Comcast I would reboot your modem first as some peopel report thsi gets them their dful speed back.
    After that talk to Comcast. They will not admit anything but things do seem to change.
    10:02 PM Saturday; August 18, 2007

  • What is System Change Option Used For?

    Hi,
    I need help on security.
    we use scc4 settings for client protection. the settings are 'No changes allowed' for client-specific objects and 'No Changes to Repository and cross-client customizing objects' for cross-client object changes.
    system change options are set to 'Modifiable'. what is the difference between these settings? Is there any situation that may cause problems?
    thanks,
    - ferudun

    Hi ,
          No Changes allowed flag is explained as below
    This flag means that changes in the customizing settings of the client
    are not permitted (client lock).
    However, customizing settings can be exported from the client by manual
    creation of a transport request. A manual transport can be carried out
    in the particular transaction for settings with the function Transport,
    which places the selected customizing settings in a transport request.
    In a productive client, the customizing settings that can be maintained
    as "current settings" are excluded from the client lock; this means that
    current settings (e.g. exchange rates, posting periods) can always be
    maintained in the productive client
    For 'No changes to Repository and cross cleint customizing objects' explained below
       o   Changes to the Repository and cross-client Customizing permitted
           There are no restrictions on the maintenance of cross-client object
           for the client when this setting is used. Both cross-client
           Customizing objects and objects of the SAP Repository can be
           maintained.
       o   No change to cross-client Customizing objects
           Cross-client Customizing objects cannot be maintained in the client
           with this setting.
       o   No change to Repository objects
           With this setting, objects of the SAP Repository cannot be
           maintained in the client.
       o   No change to Repository and cross-client Customizing objects
             Combination of both restrictions: Neither cross-client Customizing
    objects nor objects of the SAP Repository can be maintained in the
    client.
    Please reward if useful.

  • Workflow notification mailer not starting after APPS pwd change

    Workflow notification mailer not starting after APPS pwd change
    The error in the WFMAILER log is
    [appprod@nalinoes04 ABPROD_nalinoes04]$ cat WFMAILER1300061.txt
    wferr:
    - WFXXX_DB_CONNECT CODE=1017 CONNECT=APPS
    cpid=1300061, logfile=/abprod/comn/admin/log/ABPROD_nalinoes04/WFMAILER1300061.txtparams=, status=Running, debuglevel= Error Done.[appprod@nalinoes04
    Can you please advice ?
    EBS 11.5.10.2
    DB 11.2.0.1                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           

    There is no upgrade, just a usual APPS password changeYou still need to bounce the application services.
    The error you have posted above does not tell much about the issue. Please clear the log file, reproduce the issue, and check the log file then.The FNDCPGSC log file
    [Oct 23, 2012 12:42:42 PM CDT]:1351014162195:Thread[BES Dispatch Thread,5,main]:0:-1:nalinoes05:172.25.80.54:-1:-1:EXCEPTION:[SVC-GSM-WFMLRSVC-1327162 : oracle.apps.fnd.cp.gsc.SvcComponentStateMachine.updateComponentStatus(Logger, Connection, int, String, String)]:BEGIN (Logger{mLog=[$Header: AppsLog.java 115.76 2004/07/27 17:30:17 kkapur ship $ @16720915 {oracle.apps.fnd.profiles.ExtendedProfileStore@9980d5}],mUniqueId=SVC-GSM-WFMLRSVC-1327162,mLevel=4}, oracle.jdbc.driver.OracleConnection@76ab2f, 10006, DEACTIVATED_SYSTEM, This automatic Service Component has been restarted the maximum of 10 times after stopping with error. Thus, it has been system deactivated -> oracle.apps.fnd.cp.gsc.SvcComponentContainerException: Could not start component; performing rollback -> oracle.apps.fnd.cp.gsc.SvcComponentException: Validation failed for the following parameters -> {OUTBOUND_SERVER=Unable to make a network connection.}. Parameters were -> {INBOUND_MAX_IGNORE_SIZE=1000, INBOUND_MAX_LOOKUP_CACHE_SIZE=100, ATTACH_IMAGES=Y, ALLOW_FORWARDED_RESPONSE=Y, INBOUND_UNSOLICITED_THRESHOLD=2, NODENAME=WFMAIL, SEND_UNSOLICITED_WARNING=Y, AUTOCLOSE_FYI=Y, INBOUND_PROTOCOL=IMAP, PROCESSOR_READ_TIMEOUT_CLOSE=N, ATTACHED_URLS=WFMAIL:ATTACHED_URLS, TEST_ADDRESS=NONE, PROCESSOR_OUT_THREAD_COUNT=1, EXPUNGE_ON_CLOSE=Y, ATTACH_STYLESHEET=Y, OUTBOUND_CONNECTION_TIMEOUT=120, INBOUND_MAX_RET_EMAIL_SIZE=100, MAX_INVALID_ADDR_LIST_SIZE=100, PROCESSOR_MAX_LOOP_SLEEP=60, SEND_ACCESS_KEY=N, PROCESSOR_IN_THREAD_COUNT=1, FRAMEWORK_APP=1, CLOSED=WFMAIL:CLOSED, INBOUND_FETCH_SIZE=100, SUMMARY=WFMAIL:SUMMARY, ENABLE_STYLESHEET=N, PROCESSOR_ERROR_LOOP_SLEEP=60, OPEN_MAIL_FYI=WFMAIL:XXAB_OPEN_IBE_WF_MAIL, FRAMEWORK_RESP=20420, ALTERNATE_EMAIL_PARSER=oracle.apps.fnd.wf.mailer.DirectEmailParser, INBOUND_PASSWORD=_!08^@@690^6@6$$^#9^#6#!0$04868!@$^86$!!`}0$8|&%%+++|9|*@, HTTP_USER_AGENT=Mozilla/4.76, RESET_NLS=N, PROCESS=PROCESSED, OPEN_MAIL_DIRECT=WFMAIL:OPEN_MAIL_DIRECT, PROCESSOR_LOOP_SLEEP=5, MESSAGE_FORMATTER=oracle.apps.fnd.wf.mailer.NotificationFormatter, [email protected], FRAMEWORK_USER=0, CANCELED=WFMAIL:CANCELED, OUTBOUND_PROTOCOL=SMTP, ACCOUNT=svc_oracle_mail, DISCARD=DISCARD, FROM=ACCO Workflow Mailer, PROCESSOR_DEFER_EVTDATA_READ=Y, SEND_CANCELED_EMAIL=Y, WARNING=WFMAIL:WARNING, PROCESSOR_MAX_ERROR_COUNT=10, INBOUND_CONNECTION_TIMEOUT=120, HTMLAGENT=http://nalinoes04.abd.ad.acco.com:8000/pls/ABPROD, INBOX=Inbox, OPEN_INVALID_MORE_INFO=WFMAIL:OPEN_INVALID_MORE_INFO, INBOUND_SERVER=lin-hera.na.acco.com, OUTBOUND_SSL_ENABLED=N, OPEN_MORE_INFO=WFMAIL:OPEN_MORE_INFO, MAILER_SSL_TRUSTSTORE=NONE, INLINE_ATTACHMENT=N, OPEN_INVALID=WFMAIL:OPEN_INVALID, EMAIL_PARSER=oracle.apps.fnd.wf.mailer.TemplatedEmailParser, DIRECT_RESPONSE=N, OPEN_MAIL=WFMAIL:OPEN_MAIL, MORE_INFO_ANSWERED=WFMAIL:MORE_INFO_ANSWERED, HTML_DELIMITER=DEFAULT, FRAMEWORK_URL_TIMEOUT=30, COMPONENT_LOG_LEVEL=5, SUMHTML=WFMAIL:SUMHTML, PROCESSOR_READ_TIMEOUT=10, DEBUG_MAIL_SESSION=Y, OUTBOUND_SERVER=nalinoes04.abd.ad.acco.com, INBOUND_SSL_ENABLED=N})
    Please see these docs.
    How to Troubleshoot 'Validation failed' Errors when Starting the Mailer [ID 463354.1]
    Unable To Make A Network Connection For IMAP Username/Password In Workflow Mailer Configuration [ID 784247.1]
    Workflow Cannot Connect to IMAP Sever: "Unable to Make a Network Connection" [ID 577592.1]
    Error Validation Error Has Occurred: Unable To Make A Network Connection During Mailer Setup [ID 834054.1]
    Unable To Connect To The Mail Account. Check The Host, User Name And Password [ID 1123684.1]
    How to Perform a Meaningful SMTP Telnet Test to Troubleshoot Java Mailer For Sending Email Notifications [ID 753845.1]
    Workflow Mailer Will Not Start Stays In Starting Status [ID 837893.1]
    Thanks,
    Hussein

  • Please Confirm:  Can  a user change options in Viewer?

    In Discoverer 4i Viewer, can the user change options such as show null values as blank and warn me if the query will take longer than 'n' seconds?
    Thanks,
    -DG

    Yes.
    Click on the 'Options' icon in the upper right hand frame of the window (not the presentation options link above the worksheet, but rather the Viewer options).
    This will let you set both the query governor and null settings you are interested in.

Maybe you are looking for

  • IDE drives not being detected

    Yesturday I built a computer from all brand new parts listed in my sig. However, the motherboard can't seem to detect any IDE drives. It is not crashing, it just says 'None' on the 4 IDE devices. I even tried connecting just the one DVD drive as the

  • Delivery creation date field in STO

    Friends, I have created 2 STO's ...for 1st STO i can see the delivery creation date in Shipping tab......however for 2nd STO shipping tab is there but  the delivery creation date field is blank... what could be the reason...how this gets calculated ?

  • CLID restriction for Contact Center Calls

    Hi, One of our customers has a stalker and they have asked from the telco to send the Calling Line ID for the mobile calls which are normally blocked by the calling person. When these calls are to a Callmanager user, they cannot see the caller ID as

  • ICal - Migration from 10.4.11 to 10.5.2

    Hi ! I have just moved from a 10.4.11 system to a new Intel Xserve 10.5.2 Most of my users are still using 10.4.11 client systems. On my original 10.4.11 server, users published their calendars to /Library/WebServer/Documents/Calendars where the publ

  • Streaming freezing while playing, unless I touch the screen every few seconds to keep the streaming actively flowing.

    Streaming from iPad, through an app and the streaming will stop unless I touch the screen which seems to wake it up and will begin from where it stopped. Can anyone tell me why it does this? Kind of makes watching something a little annoying. It's as