QA32 DATA

Sir.
ply help me in the following tables which are linked to QA32 tcode where all the data gets stored
regards
amey

Amey,
QALS table would contain almost all data and status you can pickup from JEST table.
Other Important Qm tables,
QAMB                           QM: Link Between Inspection Lot and Mater
QAMR                           Characteristic results during inspection
QAMV                           Characteristic specifications for inspect
QAPP                           Inspection point
QASE                           Results table for the sample unit
QASH                           Quality control chart
QASR                           Sample results for inspection characteris
QASRMS                         Confirmation Data for Multiple Specificat
QAST                           Control chart track
QASV                           Sample specifications for inspection proc
QAVE                           Inspection processing: Usage decision
Regards,
Prasobh

Similar Messages

  • Regarding Credit Date in QA32.

    Dear All,
                   I am creating a daily credit  report , for this is am giving input as i.e. selection-options as credit date, my data is comming properly for certain date span but for 1 day date the data is nothig , i.e. : blank.
                   I am fetching inspection lot number , assembly date , serial no , code ,production ord no and much more, but my credit date is wrong, i think so . i am taking date as field-budat table-qals, plz give me correct table name and field name.

    > plz give me correct table name and field name.
    I had the same problem and found this usefull thread. It was like "Wahhaaaaa!"  ---> F1!
    Cool... It is even on the keyboard!! It's like everywhere!!! I'm free... (in development systems...
    Cheers,
    Julius

  • Badi or user-exit for QA32 after save

    I need a badi or user exit to execute exactly after save in QA32 ..I tried belows but they are not that i want
    QPL1_SUBSCREEN_ADDON
    INSPECTIONLOT_UPDATE
    Check these Exits:
    QEVA0004 Exit for changing information line in usage decision he
    QEVA0005 User subscreen for displaying add. data for usage decis
    QEVA0006 Entry to usage decision transactions
    QEVA0007 UD: Control of compulsory comment or long text presetti
    QEVA0008 Usage decision: Customer function key (e.g. to cancel U
    QEVA0009 UD: Predefinition of quantity to be posted to sample st
    QEVA0010 UD: Usage decision check
    QLCO0001 QM: Call alternative costs report from UD
    QSS10001 Possibility of calling a different print report

    Hello Tuncer,
    have you checked the BADI QE_SAVE? This is the last possible chance of changing data on saving a QM transaction and should be active in QA32.
    The only other solution I can come up with is a follow-up action i.e. for the UD-code
    Hope this information proves usefull.
    Regards
    Isabelle

  • Run time error QA32 of QM

    We are geting following run time error when executeing QA32 t-code of QM , error as follows ,
    Error analysis
    After a specific time, the program is terminated to make the work area
    available to other users who may be waiting.
    This is to prevent a work area being blocked unnecessarily long by, for
    example:
    - Endless loops (DO, WHILE, ...),
    - Database accesses with a large result set
    - Database accesses without a suitable index (full table scan)
    The maximum runtime of a program is limited by the system profile
    parameter "rdisp/max_wprun_time". The current setting is 600 seconds. If this
    time limit is
    exceeded, the system attempts to cancel any running SQL statement or
    signals the ABAP processor to stop the running program. Then the system
    waits another 60 seconds maximum. If the program is then still active,
    the work process is restarted.
    How to correct the error
    Programs with long runtime should generally be started as background
    jobs. If this is not possible, you can increase the system profile
    parameter "rdisp/max_wprun_time".
    Depending on the cause of the error, you may have to take one of the
    following measures:
    - Endless loop: Correct program;
    - Dataset resulting from database access is too large:
    Instead of "SELECT * ... ENDSELECT", use "SELECT * INTO internal table
    (for example);
    - Database has unsuitable index: Check index generation.
    If the error occures in a non-modified SAP program, you may be able to
    find an interim solution in an SAP Note.
    Runtime Errors TIME_OUT
    Date and Time 30.06.2009 10:17:31
    Short dump has not been completely stored (too big)
    If you have access to SAP Notes, carry out a search with the following
    keywords:
    "TIME_OUT" " "
    "SAPLBSVA" or "LBSVAU14"
    "STATUS_PRE_READ"
    If you cannot solve the problem yourself and want to send an error
    notification to SAP, include the following information:
    1. The description of the current problem (short dump)
    To save the description, choose "System->List->Save->Local File
    (Unconverted)".
    2. Corresponding system log
    Display the system log by calling transaction SM21.
    Restrict the time interval to 10 minutes before and five minutes
    after the short dump. Then choose "System->List->Save->Local File
    (Unconverted)".
    3. If the problem occurs in a problem of your own or a modified SAP
    program: The source code of the program
    In the editor, choose "Utilities->More
    Utilities->Upload/Download->Download".
    4. Details about the conditions under which the error occurred or which
    actions and input led to the error.
    System environment
    SAP-Release 700
    Application server... "GALT"
    Network address...... "202.54.13.238"
    Operating system..... "Windows NT"
    Release.............. "5.2"
    Hardware type........ "2x Intel 80686"
    Character length.... 8 Bits
    Pointer length....... 32 Bits
    Work process number.. 0
    Shortdump setting.... "full"
    Database server... "GALT"
    Database type..... "ORACLE"
    Database name..... "PRD"
    Database user ID.. "SAPSR3"
    Char.set.... "English_United State"
    SAP kernel....... 700
    created (date)... "Oct 13 2006 00:08:41"
    create on........ "NT 5.0 2195 Service Pack 4 x86 MS VC++ 13.10"
    Database version. "OCI_10201_SHARE (10.2.0.1.0) "
    Patch level. 80
    Patch text.. " "
    Runtime Errors TIME_OUT
    Date and Time 30.06.2009 10:17:31
    Short dump has not been completely stored (too big)
    Database............. "ORACLE 9.2.0.., ORACLE 10.1.0.., ORACLE 10.2.0.."
    SAP database version. 700
    Operating system..... "Windows NT 5.0, Windows NT 5.1, Windows NT 5.2"
    Memory consumption
    Roll.... 8112
    EM...... 16724736
    Heap.... 0
    Page.... 450560
    MM Used. 6688784
    MM Free. 626280
    User and Transaction
    Client.............. 400
    User................ "MGMTSER"
    Language key........ "E"
    Transaction......... "QA11 "
    Program............. "SAPLBSVA"
    Screen.............. "SAPMQEVA 0200"
    Screen line......... 41
    Information on where terminated
    Termination occurred in the ABAP program "SAPLBSVA" - in "STATUS_PRE_READ".
    The main program was "SAPMQEVA ".
    In the source code you have the termination point in line 61
    of the (Include) program "LBSVAU14".
    Source Code Extract
    Line SourceCde
    31
    32 OBJNR_TAB[] = JSTO_PRE_TAB[].
    33
    34 * Merken: jeweils bisherige Anzahl Einträge im Puffer
    35 DESCRIBE TABLE JSTO_BUF LINES JSTO_BUF_LINES.
    36 DESCRIBE TABLE JEST_BUF LINES JEST_BUF_LINES.
    37 DESCRIBE TABLE OBJNR_TAB LINES OBJNR_TAB_LINES. "Note978655
    38 ADD 1 TO JSTO_BUF_LINES.
    39
    40 l_percentage = OBJNR_TAB_LINES * 100 / JSTO_BUF_LINES. "Note978655
    41 * Small number of object numbers to be read, insert records "Note978655
    42 * sequentially to avoid expensive SORT on JSTO_BUF,JEST_BUF "Note978655
    43 IF ( l_percentage <= 1 OR OBJNR_TAB_LINES < 20 ) AND "Note978655
    44 get_change_documents IS INITIAL. "Note978655
    45 LOOP AT objnr_tab. "Note978655
    46 SELECT * FROM JSTO CLIENT SPECIFIED "Note978655
    47 FOR ALL ENTRIES IN OBJNR_TAB "Note978655
    48 WHERE MANDT EQ CLIENT "Note978655
    49 AND OBJNR = OBJNR_TAB-OBJNR. "Note978655
    50 READ TABLE JSTO_BUF WITH KEY MANDT = JSTO-MANDT "Note978655
    51 OBJNR = JSTO-OBJNR "Note978655
    52 BINARY SEARCH. "Note978655
    53 IF SY-SUBRC <> 0. "Note978655
    Runtime Errors TIME_OUT
    Date and Time 30.06.2009 10:17:31
    Short dump has not been completely stored (too big)
    54 JSTO_BUF = JSTO. "Note978655
    55 CLEAR JSTO_BUF-MOD. "Note978655
    56 JSTO_BUF-STSMA_OLD = JSTO_BUF-STSMA. "Note978655
    57 INSERT JSTO_BUF INDEX SY-TABIX. "Note978655
    58 ENDIF. "Note978655
    59 ENDSELECT. "Note978655
    60 "Note978655
    >>>>> SELECT * FROM JEST CLIENT SPECIFIED "Note978655
    62 FOR ALL ENTRIES IN OBJNR_TAB "Note978655
    63 WHERE MANDT EQ CLIENT "Note978655
    64 AND OBJNR = OBJNR_TAB-OBJNR. "Note978655
    65 READ TABLE JEST_BUF WITH KEY MANDT = JEST-MANDT "Note978655
    66 OBJNR = JEST-OBJNR "Note978655
    67 STAT = JEST-STAT "Note978655
    68 BINARY SEARCH. "Note978655
    69 IF SY-SUBRC <> 0. "Note978655
    70 JEST_BUF = JEST. "Note978655
    71 CLEAR JEST_BUF-MOD. "Note978655
    72 JEST_BUF-INACT_OLD = JEST_BUF-INACT. "Note978655
    73 INSERT JEST_BUF INDEX SY-TABIX. "Note978655
    74 ENDIF. "Note978655
    75 ENDSELECT. "Note978655
    76 ENDLOOP. "Note978655
    77 CLEAR: JSTO_BUF,JEST_BUF. "Note978655
    78 EXIT. "Note978655
    79 ENDIF. "Note978655
    80
    Contents of system fields
    Name Val.
    SY-SUBRC0
    SY-INDEX0
    SY-TABIX15
    SY-DBCNT15
    SY-FDPOS1
    SY-LSIND0
    SY-PAGNO0
    SY-LINNO1
    SY-COLNO1
    SY-PFKEYA101
    SY-UCOMMBU
    SY-TITLE Record Usage Decision: Characteristic Overview
    SY-MSGTY
    SY-MSGID
    SY-MSGNO000
    SY-MSGV1
    SY-MSGV2
    SY-MSGV3
    SY-MSGV4
    SY-MODNO0
    SY-DATUM20090630
    SY-UZEIT101723
    SY-XPROGSAPLQAMB
    SY-XFORMCONVERSION_EXIT
    Edited by: Raghavendra Balegar on Jul 3, 2009 12:21 PM

    No Dear,
    Not at all. I think it should work for atleast one month period.
    But sometimes depending on the database size and hardware, this criteria can vary.
    Regds,
    Anil

  • Inspection lot not appearing in QA32

    Dear Experts,
    We have transfered a batch  from a storage location of one plant to the storage location of another plant through movement type 909 with all require datas entered and saved the transaction . But while we checked in MB51 and QA32 , no material document or a Inspection lot for stock transfer not appearing.
    When checked for the logs Message QA 150 appearing for ' Errror inserting QALS as update was terminated ' . What to do ?
    Thanks.

    Hi
    Is 909 is SAP's standated Mvt type?
    Check the setting for this mvt type in QCC0->Qulity inspection->Inspection for goods Mvt.--->Inspection lot origine & Deactivate Quality inspection.
    I have a suggesion.for transfering Material from one plant to other SAP has own Mvt type:301(single step--->Without purchse Order).You can active 08 inspection type for Material at receiving plant.It will create a lot at receiving plant.
    In addition to this 351& 352 are used when purchse order(STO) is there.
    In hop this will help me.
    revert back for any Querries.
    Regards
    Sujit Gujar

  • How to differentiate defects in QA32 using Traffic light

    Hi QM Experts,
    My scenario is,
    How to set Monitor control in QA32 screen.
    In the QA32 screen list of inspection lot will be displayed, for that inspection lot if any characteristics value is within / outside the limit, ie. for example specification is A2,R3 and i found 1 defect also defect is 4.
    how to differentiate this with the help of Traffic light.
    Regards,
    Krish

    Hi Krish,
    As per best of my information, the traffic lights in QA32, depends on the Start Sate and End Date of the inspection lot.
    If the End Date is not passed away (the current date is between the Start Date and End Date) it will be yellow.
    If the End Date is Passed away and UD is not not for the Lot then the traffic light will be RED and as soon as UD done at any date/stage the light will become Green.
    Conclusively, the light can't be linked with Defect Codes.
    Regards,
    Shyamal

  • New lot not appearing in qa32 - v urgent

    Hi all,
    I have an urgent issue to resolve. we have developed a report that shows those batches
    -for which UD has been done 8 days before but no despatch till date  OR
    -for which no UD has been done and date of production is 8 days before from today.
    User wants that a new lot for above batches should appear for UD again in qa32.
    For this i have defined procedure as:
    1.  Run REPORT  Which will identify batches older than 8 days (from the days of production or last UD date).
    2.Go to QA07 Enter material codes, Batch numbers, and plant and select the option of Block Batch at lot creation.This will transfer all the mentioned batches to blocked stock and create an inspection lot automatically.simultaneously an inspection lot will start appearing in transaction QA32, against this batch for inspection.
    Now the issue is that after QA07, I can see in mb52 that stock of the batch move to restricted, but no inspection lot appears in qa32. a new inspection lot should appear in qa32.
    any ideas ? have i missed anything? i have also done changes in inspection plan,
    cant figure out what i missed. pls respond.
    Regards,
    Aisha Ishrat
    ICI Pakistan Ltd.

    Let me simplify my question:
    i have some batches in system for which UD had been done 8 days
    before but no despatch has been done against those batches.User
    want to give UD again for those batches.
    what i advised him to change the inspection plan of those
    materials by putting '9' in 'usage' and '4'in 'status' fields in
    qp01 and then go to qa07 and enter material codes, Batch
    numbers, and plant and select the option of Block Batch at lot
    creation.The batches automatically transferred to blocked stock.
    Now the issue is that after batches transferrence to block stock,
    new lot should appear in qa32 but its not appearing.any ideas??
    Have I missed any thing? Kindly give a prompt reply.

  • QA32 spreadsheet needs to unmark the button "always use selected format"

    Hello Experts.
    I am currently doing some testings in QA32, i want to transfer my list in printable documents, when i am in the menu LIST- EXPORT - SPREADSHEET , then the list for choices appears if(excel, all available formats)then there is this button box "always use selected format" which i have marked it and saves..then when after i proceed to QA32 again, i can't choose the format that i want in the selection.I believe it is the result of marking the button "always selected use format"
    how can i unmarked the  button "always selected use format" so i can have the chance to choose again?
    Thanks

    Exporting to Spreadsheets  
    Use
    You can export the list as various spreadsheet formats. The following list summarizes the most important of these formats and the corresponding file name extension for the files:
    Format
    File Name Extension
    Excel (in MHTML format)
    MHTML
    Excel (in MHTML format for 2000/97)
    MHTML
    Star Office (in ODS format 1.0)
    ODS
    Excel (in Office 2003 XML format)
    MHTML
    SAP-internal XML format
    XML
    SAP standard (internal table)
    XML
    Excel (in previous XXL format)
    XLS
    A format is only included in the selection options if it is available on your PC. The system administrator can also restrict the list of possible formats or even reduce the export to a certain format.
    When you export the list in one of these formats, the system automatically generates a file with the name export and with the corresponding file name extension. Exactly which parts of the list are exported to the file depends on the format.
    Exactly which data is exported to the file depends on the format:
    ●      In MHTML and XML formats, for example, you export the data that is displayed in the list on the screen. The number, selection, and sequence of columns as well as the sorting, filter, and calculation settings are all included in the export.
    ●      In Excel XXL format, any functions that you executed on the list are not included in the export. The file contains all the columns that you have displayed, but your sorting, filter, and calculation settings are ignored.
    Prerequisites
    To be able to display and, where necessary, further edit the file that you have generated with the export, the relevant program must be installed.
    Procedure
    Exporting the List
           1.      Choose  with the quick info text Export and select Spreadsheet in the selection list. In full-screen mode, choose List ® Export ® Spreadsheet.
    If you have a choice of more than one format, the Select Spreadsheet dialog box opens.
           2.      In the Select Spreadsheet dialog box, select the format in which you want to save the exported data.
           3.      Confirm the settings.
           4.      In the dialog box that appears, specify the path and name of the file and save the file.
    For some formats, you also need to specify other settings for the file that is saved.
           5.      Make the required settings, where applicable.
    If an installed program is linked to the selected file name extension, this program is started automatically and the generated file is opened.
    Keeping Settings
    If you plan to reuse the same spreadsheet format, you can save the settings for the format. By doing this, you can omit the step with the Select Spreadsheet dialog box and can export the list more quickly.
           1.      Proceed as described above in steps 1 and 2.
           2.      In the Select Spreadsheet dialog box, select Always Use Selected Format.
           3.      Confirm your settings and continue as outlined above.
    From now on, whenever you export your list as described above, you bypass the Select Spreadsheet dialog box step and proceed immediately to saving the data.
    4.      If you want to display the Select Spreadsheetdialog box again during the export, in the context menu for the list, choose Spreadsheet.
    The dialog box opens; the Always Use Selected Format indicator is not set.

  • Not able to see inspection lot in QA32

    i did MIGO, but i could not see the inspection lot in QA32.so i checked it in MMBE.
    there material is showing in Quality inspection stock.

    Hi Sandeep,
    Check the folowing points,
    See date range, secondly select radio button as lots without UD in list setting,
    or check your input parameters.
    Reward points if useful.

  • Need to Change Result in Transaction QA32

    Hi all,
    Is it possible to change my Result value in transaction QA32 after save all data and post data. Means i can save my data but now i have to change my RESULT VALUE in QA32 so it's possible .
    And it's possible then please kindly describe me step for change this.
    Thanks in Advance.
    Keyur

    Hello Keyur,
    You can change the inspection results. There are 2 cases.
    You have recorded, valuated results and stock posting done but UD not given
    1.     Go to QA32 again and click on result tab
    2.     Here select the parameter that you want to change
    3.     After selection the line click on unlock symbol (Just right to lock symbol)
    4.     The window will turn in to editable mode
    5.     Change the readings, valuate, lock again and save
    You have recorded , valuated results and stock posting done and UD also given
    1.     This is possible only if you have ticked on  long term inspection of MIC that you use.
    2.     This setting has to be done before lot creation. I mean if you tick this now, this will take effect from next lot and not for existing lot.
    3.     By means of this even if you have given UD, you can change the results.
    Please get back in case of further doubts.
    Best Regards,
    Anand Rao

  • QA32: Stock In Quality But no Inpsection Lot

    Greeting..
                I have raw maetrial which i recievd against Purchase order , and its showing under qulity stock in stock overview.....But in QA32 i m not getting the Lot for this..no where i m founding the Lot of this material..
    How to make this stock to Unrestricted stock ????
    what is wrong???? what are the possible reaon??

    Hi,
    In QA32 also, you can get the lot number with the material doc number.
    In QA32, there is an option called dynamic selection ( a red color option on the top of the screen ) there you will find the option " procurement".under procurement you get the option " material document".
    double click on that option...........material document option will come in the selection screen.......put the material doc no  there......erase all other default values, i.e. lot creation date ( the date range from the present date to previous 7 days ago).........
    even if you dnt know the material doc and you know the PO no.,under the option procurement, you will get purchasing doc option............if you put the PO number, system will give you the lot no.
    you are getting the error in mb1b , because the material is subjected to QM..as you have assigned required inspection type ( 01) in the material master....you can not do stock transfer from unrestricted to QI
    ......partha mukherjee
    Edited by: partha mukherjee on Apr 10, 2009 7:22 AM

  • Want to add new field in QA32/QA11 transaction under inspection lot stock

    Dear Experts,
    I want to add new field in QA32 transaction under inspection lot stock tab or under characteristic tab.
    The reason behind is: Depends upon UD decision i want to assing customer name. So already we are having one Z Report for all the lots against this lot we have to display customer name.
    So in order to fetch customer name in the Z report we want to assing customer through F4 selection in the usage decision  screen.
    I know this is possibe for Make to order scenario, but our senario is make to stock.
    Please advice your valuable inputs.
    Regards.

    Hi Sujit,
    Can you please elaborate it,coz i'm using the same but if i place the break-point in PBO of sub screen,the break-point won't be triggered.and is there any additional step to get the data from function group? if yes, please explain me indetail.
    If possible please provide the sample code for this.
    Thanks Inadvance.
    Madan
    Edited by: Madan.ngt on Mar 3, 2011 7:16 AM
    Edited by: Madan.ngt on Mar 3, 2011 7:17 AM

  • BADi in QA32 and COR3

    Dear All
    I am searching for badi in QA32 and COR2 .IF any one have done this please do let me know.
    As well i serached for badi
    These are the BADI's:Check once.
    QPL1_SUBSCREEN_ADDON
    INSPECTIONLOT_UPDATE
    Check these Exits:
    QEVA0004 Exit for changing information line in usage decision he
    QEVA0005 User subscreen for displaying add. data for usage decis
    QEVA0006 Entry to usage decision transactions
    QEVA0007 UD: Control of compulsory comment or long text presetti
    QEVA0008 Usage decision: Customer function key (e.g. to cancel U
    QEVA0009 UD: Predefinition of quantity to be posted to sample st
    QEVA0010 UD: Usage decision check
    QLCO0001 QM: Call alternative costs report from UD
    QSS10001 Possibility of calling a different print report
    but then too my req was not done
    i want to add fields in qa32 which are there in MIGO (in migo down in general i want to get Delivary Note, Doc Header text,
    DOWN in where tab i want to get goods recpipent,unloading point)
    Thanks in advance
    Sravya

    no answer from long time

  • Inscrease the decimal Places in Tcode QA32(UD)

    Hi Guys,
    I want to increases decimal point in Tcode QA32 .
    My user requirement is to increases the decimal places from 3 to 4 in Inspection lot stock / to be posted.
    We maintain 3 decimal places & I want 5 decimal places at the time of Usage Decision. But I couldn't found the required customizing setting.
    Please suggest me....

    Hello,
    Changing Data Types and Lengths of Existing Fields
    If a data element is assigned to the field, you must change the technical field attributes (data type, length, number of decimal places) in the domain of the data element.
    Procedure for Fields with Data Elements
    Double-click on the name of the data element.
    The data element maintenance screen appears.
    Double-click on the name of the domain.
    The domain maintenance screen appears.
    Choose Domain ® Display ® Change.
    Make the required changes and save your entries.
    Note that this change affects all the table fields that refer to the particular domain. Foreign keys could become inconsistent and conversions required. You should therefore consider the effects of this action before changing the domain by choosing in the maintenance screen of the domain and checking if the domain is used in other tables.
    Choose .
    The table is activated again and the table field is adjusted to the domain change.
    Procedure for Fields with Direct Type Entry
    Place the cursor on the field and choose Data element / Direct type.
    Values can now be entered in fields Data type, Length, DecPlaces and Short text.
    Change the entries for the data type, length and possibly the number of decimal places.
    Save your entries.
    Choose .
    Note that a table conversion will normally be necessary (see Adjusting Database Structures) if you change the field attributes
    NOTE: You need to have Access key.
    Regards,
    Alok Tiwari

  • Additional columns in QA32

    Hi,
    Is it possible to include new columns like Production Work Center, Personnel No., Personnel Name, Execution Start Date and Time, Execution Finish Date and Time in QA32. The same data were already entered in CO11N.
    Kindly help me.
    Regards
    V. Devaraj

    Dear Deveraj
    I will suggest you to create a  Zreport for this. QA32 is a standard screen , so avoiding any developments will be always better
    Regards
    Gajesh

Maybe you are looking for

  • Page item validation

    I created a page in APEX Express 4.2.3.00.08.  On the page there are two items: a text field named P55_KEY_ID and an LOV named P55_REASON with the values LOST, BROKEN, OTHER.  I created a dynamic action that enables P55_REASON when P55_KEY_ID changes

  • Syncing multiple iPhones with iCal and contacts

    My roommate just bought an iPhone and synced it for the first time with my iMac, but now he has all of my contacts and calendar appointments and none of his own. Do iCal and Contacts support multiple profiles? Is it possible for him to store his cont

  • Vat report for Poland

    HI! I´m using the report S_ALR_87012385 - VAT Register (Poland), and it seems it work correctly, but how can i prevent the documents from being caught twice in both report's executions to the same date? there is same way for the knows that the docume

  • [ACE] Real servers and VIP in the same VLAN

    Hello. I´m facing an issue because the real servers and the VIP address are in the same VLAN, when a request comes from an external client to the VIP (crossing an ASA firewall) , the ACK gets back using the IP of one of the real servers instead of th

  • IPad 3 16GB; 6GB free; hard restart; upgrade via wifi to 8.1.2 failing, plugged in; scrolled to end of T

    iPad 3 16GB; 6GB free; hard restart; upgrade via wifi to 8.1.2 failing, plugged in; scrolled to end of T&Cs before clicking on Agree.