QM/WM- LT05 Screen after QM stock posting

Hi
Is there anyway to trigger the LT05 screen appearing after a stock posting in the inspection lot ? We have it working when doing a partial UD using the follow-on action, but when we want to just pre-release part of the inspection lot we can't get the 321 movement from within QM to trigger this screen appearing.
Any ideas ? Or do we need to do this via a user exit?
thanks in advance.
Al

Well, i thought about your suggestion too. It seems a good alternative. Another option is during GR in quality inspection stock to create a TO towards a workcenter. But, like the sample bin solution you suggest, i still have no physical transfer of the sample quantity to the other storage location.
The reason my client wants this is to have better insight in what stock is physically in which storage location. The storage location where the materials are tested is physically 100 km from the central warehouse. So the sample has to be shipped from the central warehouse (WM managed) towards the warehouse where they test the samples.
As you describe we can put the sample in the storage bin in Q stock and wait for them to be approved and the post them to unrestriced use stock by the user decision. But still the physical transfer is not solved in my opinion. What am i missing?
We have other non WM managed storage locations too which we supply from the central (WM) managed warehouse with materials (via MRP run). The (UB) purchase reqs result in a (UB) purchase order, then we convert them into a (NL) delivery with VL10B and create a shipment and a pick (transfer) order and ship them from the WM stor loc to the other non WM stor locs.

Similar Messages

  • Blank screen after hibernate, no post

    Toshiba satellite l505d-s5983
    I have had this laptop for 4 years, and recently i was running into an issue where my laptop may die in hibernation during my commute.
    Usually, I could pop the battery out, use wall power, and windows would resume...
    However, one day it just wouldnt come back.
    I have tried draining the battery, taking it out, draining the laptop and plugging it back into the wall with no progress.
    On boot, LED, USB, DVD, Fans, all work...  caps lock and numberlock flash, and go out....
    Screen remains black, no post. I have a toshiba windows 7 disc, but it does no good.
    I bought a usb/sata cable and I can access my HD and save my data, so the HD is good
    I swapped ram chips one at a time in alternating slots and received nothing.
    I plugged the ram into my girl friend's toshiba and it boots fine. So the ram is good.
    I attempted using her powercord,  and got nothing.
    I plugged up my desktop monitor and got nothing.
    I have tried fn/f5 as well and got nothing.
    I took apart the laptop, cleaned it up... stripped it down to the basics, plugged in the power and still nothing on the screen.
    Having given up,  I bought the exact same laptop on ebay, thinking I could swap the HD's and be good to go...
    When I received the laptop, exact same situation... alternated hd, ram, nothing. 
    It appears to be stuck in hibernation, but I would assume that some combination of wall power, or draining/chargining would fix it on at least one of the two laptops.
    Thoughts?

    Thanks for the quick response...
    Hi You said you have the Windows 7 disc, but it does no good. Are trying to boot from the disc. What actually happens. Do you have the boot order set to boot from CD/DVD first and HD second. Are you powering off your PC with Bothdisc in CD Rom and then powering on your PC? 
    I get a blank screen and I do not even make it to post (toshiba screen) to change boot order. When I power on the laptop, and put the disc in you can hear it spin as if it is attempting to load, but nothing ever comes on the screen. I have also tried leaving the disc in, and powering on the laptop.  - With both, my laptop, and the ebay laptop.
     If you can't boot with the disc and the disc is good, you could be looking at a power supply problem, could have a bad power jack or the worst, a bad mother board. You said you tried her power cord. Not wise unless they are the same model.
    I have 2 off brand power cords, specifically for my laptop. Both cords receive power at the box, and seem to do fine charging the batteries  for both as well. As a side note, booting with AC unplugged doesn't result in any changes. Her laptop (the 3rd toshiba) is an A205, and seems to have no problem using one of my cords.
    Can you borrow a external monitor??
    I have a monitor for my HP desktop, which is functioning. When I plug it into the wall, and into either laptop (and attempting fn+f5) I get nothing. No signal from the monitor.
    PS Did you get a power adapter with your ebay PC?
    It was suppose to be missing a power adapter and an OS. The seller is a computer repair place. There were pics of the laptop at post, and it is the same laptop because it shares a scratch with what was received. The guy is willing to refund me, but it just seems odd that I would come across 2 laptops of the same model with the same problem. 
    I spoke to another repair person on FB that suggested taking out the cmos to drain the board, but it is soldered in. I have also left the battery and plug out for 24 hrs, thinking it may help drain some juice, to no avail.
    I have been googling for almost 2 days, between msg boards/youtube etc... and i'm pretty stumped. I am not taking apart the ebay model, but i have tried practically everything i can think of, as far as disconnecting components on mine, and hoping for a post.
    ultimately, I want to be able to use my hard drive as is, in a laptop, primarily because of the programs that are installed, with the least expense attached as my job will not replace the laptop.

  • GR Cancellation after stock posting

    Hi Gurus,
    QM persons have done result recording and posted the stock to unrestricted stock.Now the production person want to cancel the GR. But system is not allowing cancellation of GR.Is there any way to cancel GR after stock posting.
    Regards
    Amit

    Dear,
    T. Code MB1B & movement type 344, you can transfer the Material from Unrestricted use to Block Stock.
    Or MBST and reverse the GR you have done , then use movement type 102 in the MIGO or MB31.
    Please check SAP note note 33924 Reversing the UD and 175842-QM lot stock reversal.
    Regards,
    R.Brahmankar

  • Stock posting screen

    I am doing UD and stock posting of FG material (04 insp type). I wounder "proposal" button is not coming in stock screen. What could be reason?
    Can you suggest?

    In mb51 enter material , pant anf f8
    click on current display variant , 2 tabs wil appear header and position , click on position- if u select Document Header Text header text will appear and select Text for item text and click on copy
    stored in Text - SGTXT field in MSEG TABLE
    for this u have to enter both the texts and ppost some quatity, so that mvt. happens in background anf for that mvt. type text will appear in mb51

  • QM-result recording after doing usage dcision and stock posting.

    HI gurus,
    My client is steel manufacturing industry.The requirement of client is that, after doing usage decision and stock posting they want to do result recording.Thy want it like this because in case of urgency they pass the material and afterward they do the result recording.Is such a scenario is possible in standard sap.If yes pls. provide me the solution.
    Thanks in advance.

    I wouls suggest you look at Jan's suggestion.  Setting everything as LT characteristics is
    1) not a good quality practice
    2) you would still have to manually to the UD I believe, auto UD won't work.  So if you have to manually process the lot anyway, you may as well just make the sotck posting and leave the lot open for results recording.
    Craig

  • Changing result Recorded after UD and Insp Stock posted.

    Hi,
    Is it possible to revoke or change the result recorded after UD is given and also stock posted for material.
    In inspection plan i have activated the  long term inspection check box for that particular MIC for which i want to change the results.
    I have done UD reversal, stock reversal etc.
    Then
    I hv tried through QE02 but its showing:
    Short term Inspection Completed.
    All Insp.Completed.
    UD has been Made.
    pls suggest the possible solution on this.
    Rgds,
    Yogesh

    Dear sujit,
    We have Ztcode developed for Stock posting reversal not for UD reversal.
    Just want to know inspite of checking box for Long term planning in MIC also in Inspection plan.
    Is there any provision for reentering results for already closed MICs.
    User has made wong input entry while recording results.
    Rgds,
    Yogesh

  • Inspection lot summary after UD and stock posted

    lot summary level '2' had maintained in material record, when GR, lot summary work rightly.
    But after UD and stock post to unrestricted stock and new GR, no inspection lot generated and stock were posted to  unrestricted stock  directly.
    My question is ,why system does not generate new inspection lot?
    I also found it in document that , lot summart does not take place if "A previously created inspection lot has already been completely credited from the stock", is that means system will create new lot in this situation?
    Regards,
    Denis.

    Denis,
    After UD
            If the UD is accept, SAP will not create new inspection lot.
            If UD is reject SAP will create a new inspection lot.
    If UD is not made but 'Qty to be posted' is zero then also SAP will create new inspection lot for subsequent goods receipts.
    AKM

  • Stock posting through mb1b

    Hi gurus,
    My client manufactures 10 steel plates from 1 slab.Every plate has different batch no.In material master QM view is maintained.
    Clients requirement is that he must be able to do stock posting for all batches through MB1B mvmt type 321 after Result Recording.But when we try to do this we get error message posting can be done through QM only.
    Is it possible to do stock posting for automatically created lots through MB1B.
    Regards
    Amit

    Hi Amit,
    Since quality management is active for the said material, you cannot use MB1B transaction to post until you make a decision on the usage of the material/batch.As you have mentioned, these inspection lots are stock-relevant or these were created automatically as a result of goods movement. This setup were defined in the Quality management screen (inspection set-up).For you to make posting stocks from quality, you need first to release the materials by QA11 whether you are to accept or reject. In QA11, you can then post the stocks to other stock types manually or automatically. Hope this helps.
    Edited by: Jay Pee Salilig on Oct 5, 2008 5:21 PM

  • Inspection lot stock posting issue

    Hi
    My inspection lot  for qty 23 no's was created after doing GR against PO. While doing Usage decsion for the same, I wanted to post  20 qty to unresticted and 3 qty to reurn to vendor .when I went to the ispection stock tab page in UD , and tried doing the same  there was an error while saving the same.
    However the ispection lot status changed to UD ICCO SPST.
    The stock is still lying in QI stock.I can see that in the stock report MMBE
    Now my issue is that I am not able to post the quantity to unresticted stock. While i try to change the inspecton lot in QA12 transaction , the system issues a message that UD is done and hence cannot change.
    Please do suggest how I can over come this issue and post stocks to Unresticted stocks
    would request you pls provide input for the same
    Thanks
    Vikrant

    What you don't tell us is what does your stock overview report show?  The status SPST indicates that stock posting has been started which means that something has been posted somewhere.
    Go and display the UD.  Look at the stock posting screen and see what it says has been posted.  Verify that it matches what you see in MMBE in the stock overview.
    Did you access QA12 directly or via the QA32 worklist.  Try using QA12 in the command line and see if you can get into it.  Typically you should always be able go back and change the UD code.
    Report back to use what you find.
    Thanks,
    Craig

  • Auto stock posting based on Calculation

    Hello to all,
    Client receive a raw material, Quality checks impurity level. 2% is acceptable impurity. If impurity is within 2% stock posting is done for total GRN qty.
    If impurity is more than 12%, lot is rejected and entire qty send back to vendor.
    Now my scenario is if QC records impurity as example 7% the they
    calculate 7-2=5% here 2 is earlier mentioned allowable/acceptable impurity.
    Then they have to deduct 5% from total qty and post it to
    Unrestricted stock. Client is asking for this automatic calculation and auto stock posting to Unrestricted stock based on deduction calculation.
    Can any one suggest a solution for this.
    Here I am giving an example.
    Impurity= 7%
    Impurity above allowance= 7-2=5%
    GRN qty=1000 kg
    Calculation for deduction = [1000- (1000*(5/100) )]= 950 kg = qty needs to be posted to unrestricted stock.
    Client needs this calculation to happen automatic and this qty
    should be automatically posted to unrestricted stock. He is not willing to calculate this and put qty manaully.
    Is there any solution available.
    Thx in advance

    Did you read the help on the enhancement?  This is from 6.0.
    If you use this, you must do the posting via posting line VMENGE08 and only the posting from this line will be affected by the User exit.
    Description
         The customer exit enables the control of a separate quantity posting in the usage decision.
         A prerequisite for activating the exit function is that you use the quantity postings to other stock on the stock overview screen of the usage decision transactions.
         To do this, you must activate the fields for quantity bookings to other stock for the inspection type field using the transaction SFAC (Customer field selection). After they are activated, a new quantity appears in the stock overview for the usage decision.
         In addition, in view TQ07M  you need to maintain the movement types for field RQEVA_VMENGE08 .
         The exit permits you to influence the quantity posting using structure QBEFU. Here, additional data can be determined and returned.
         The posting is then carried out according to the changed data as part of the normal usage decision postings.
    Edited by: Craig Snyder on Apr 1, 2008 9:29 PM

  • Black screen after windows auto update

    New laptop in use for 3 weeks.  After Windows auto update restart I get to splash screen and am able to enter Windows password to log onto desktop.  After successfully entering password I am not able to view my desktop; I get the black screen with cursor function; cursor disappears when moved within an inch of left or right of screen (seems to go behind something).  I believe I am at the desktop but just not able to view it, because I receive app popups on the black screen (need to update McAfee, etc).
    In safe mode I restored to pre auto update date; manually installed all Windows updates;  worked fine until NEXT auto update, same problem.
    Graphics Card:  Stock Intel HD Graphics
    Monitor:  Generic PnP
    Why would it be fine with the manual update and not after auto update?
    I do not have an external monitor to attach this laptop for diagnosis.  I have run windows partition checks and hard drive partition checks with no issues to resolve.
    I did get an error message once when running a diagnosis (can't remember which) : Windows Update Error 0x80070490
    No real luck finding anyway for me (the average Joe) to resolve this issue.
    If this is a harddrive issue I don't want to keep pussyfooting around while my warranty window shrinks. 
    I have downloaded driver updates from HP, but cannot get the Synaptics Touchpad driver to download.  I don't think this is my issue though.
    I am going to manually update all my drivers then manually update Windows.  We will see what happens on the next auto update.
    Please advise if this is an issue I need to just give up on and return this laptop for replacement.  It seems like this is not a completely unheard of issue, but I'm shocked at what we are asked to do to attempt to resolve it.  Out of my depth.

    Hi @Justanothermom 
    Welcome to the HP Support Forums!
    I understand that you are having troubles with a black screen after an update. I am happy to help you with this.
    Firstly, there is nothing wrong with modifiying your update settings. I was going to suggest it myself as I read through your post, and then saw you ask the question. Sometimes updates can have unintended results by the creator. With all the different combinations of  hardware, and the fact that updates come from different sources, it is one of those things that is hard to completely control.
    Please see the following for how to make adjustments to your update settings.
    Turn automatic updating on or off - windows.microsoft.com 
    Or if you know which update seems to be causing the issue you can take a look at this page:
    win 8.1 August 12 updates - black screen after 2nd reboot - answers.microsoft.com
    Let me know if this helps at all.
    Malygris1
    I work on behalf of HP
    Please click Accept as Solution if you feel my post solved your issue, it will help others find the solution.
    Click Kudos Thumbs Up on the right to say “Thanks” for helping!

  • 270X Gaming - Black screen after driver install

    I just recently purchased an MSI R9 270X Twin Frozr Gaming.
    I physically installed the board and booted my PC. Windows started fine, albeit in VGA mode. I then proceeded to install the latest AMD drivers for the card (13.11 Beta). I made it through installation and then rebooted. When I rebooted, I got a blank, black screen after the "Starting Windows" screen. I was unable to boot windows, so I restored to last known configuration and tried again with different drivers (13.9) with the same result.
    Does anyone know why windows hangs when it loads the display driver? Any help would be much appreciated.
    Thanks
    Windows 7 x64 SP1 (fresh install)
    ASRock Z77 Extreme4
    Core-i5 3570K (no overclock)
    4x4GB Corsair Vengeance (stock profile)
    Rosewill CAPSTONE 550W ([email protected])
    MSI R9 270X Twin Frozr Gaming (S/N 602-V303-03SB1309077057)

    Hi everyone. I just wanted to give you an update. It seems I have resolved the problem.
    After attempting other fixes (fresh Windows install, MB BIOS update, etc), flashing the BIOS of the video card fixed the problem. I used the BIOS version
    015.040.000.000.002887. I believe the BIOS the card shipped with is 015.039.000.000.002887. Anyway, there are no problems now. I was able to install Catalyst 13.11 Beta 9.5 with no problems and no black screens.
    I got the BIOS and ATIWinflash from TechPowerUp. I'd post links, but I am too new to the board.
    Thanks guys.

  • Samsung Galaxy S4 stuck on Verizon boot screen after installing update

    A few days ago my phone prompted me to install a software update, which I did. Since then, the phone (which was functioning perfectly fine before I installed the update) started acting up. I kept getting messages about apps that stopped working, then the phone started randomly rebooting itself, and now it has been stuck on the Verizon Startup screen. After reading several posts on this site I tried the following: (1) remove battery and reboot; (2) try reboot in safety mode keeping the volume button down during start up; (3) empty cache using menu that appears when holding volume button up during reboot; and finally (4) delete all data and restore factory settings (using same method as under (3)). All of this didn't work and I'm still stuck on the same white Verizon screen.
    Of course this happens while I am travelling abroad for 10 days and have no access to Verizon until I'm back. Is there anything I can do that I haven't tried yet? Or is my only option to get a new phone?
    Reading some of the other posts, it seems that more and more people are having the same issue after the latest software update. VERIZON - PLEASE HELP!!!

        Hello Flying_Dutchman
    I never want our customers to be without a device. Thank you for all the troubleshooting you've done. I'm sorry to say since a hard reset has been done. The next step will be to replace the device. Please reach out to us as soon as your back and we can get a replacement sent out.
    JoeL_VZW
    Follow us on Twitter @VZWSupport

  • Lenovo G560 - Issue with won't boot and black screen after HDD upgrade

    Lenovo G560 - Issue with won't boot and black screen after HDD upgrade.
     What happen: My laptop was working fine, no blue screen issue, no funny business at all. I bought a new SSD Intel 120 GB and thought it would be a good idea to replace the HDD. I shutdown and disconnected the power adapter, waited a couple of minutes and removed the battery. I opened up the back case and replaced the HDD. And put all the screws back and put the battery back in.
    Problem: The very first time I turned the power on, nothing happens besides a black screen. I pressed the dvd drive it works and opens up and closes. I waited for about 30 mins and still has blac screen. When I mean black screen, no bios menu, no logo, just a black screen with the fan sound on.
    I have tried these:
    1. Unplugged everything - battery, adapter, and pressed the power on button for about 60 seconds, nothing, the laptop turns on with the LED display on for both on and battery LED's. But nothing but black screen, no sound of windows loading just the fan and black screen.
    2. I tried putting back my old 2.5" and nothing but black screen.
    Thoughts and suggestions?
    Solved!
    Go to Solution.

    Hi Autoexit173,
    Welcome to Lenovo Community!
     As per the query we understood that you are facing issue with system not booting in your Lenovo G560 laptop.
    As you have mentioned that the system not booting, please try to remove the RAM and  turn on the system and check if you can hear any beep sound. Also try to clean the RAM slots and check for the issue.
    Click here for the steps to remove the RAM and refer page number 40.
    Hope this helps. Do post back if issue persists!
    Best regards,       
    Ashwin.S
    Did someone help you today? Press the star on the left to thank them with a Kudo!
    If you find a post helpful and it answers your question, please mark it as an "Accepted Solution"! This will help the rest of the Community with similar issues identify the verified solution and benefit from it.
    Follow @LenovoForums on Twitter!

  • A/P invoice and stock posting

    Hi
    I have some issues with understanding the following:
    I have received some item without having issued a PO for them. For these items, master data exists .
    As common practice with a lot of suppliers, there is no Invoice attached to the shipping, only a delivery note.
    If I post the items to stock using 'Goods receipt' and use A/P invoice some days after when the invoice arrives, I have doubled the received quantity by posting the items to the stock twice.
    What is the solution to have the items posted to stock immediately for further usage and adding the A/P invoice later but without stock posting?
    Thanks
    Franz

    Hi Franz,
    When an AP Invoice is based on a Goods Receipt PO there will be no double posting, not for Warehouse quantites or in the accounting.
    An AP Invoice that is based on a Goods Receipt PO where nothing was changed between the Goods Receipt and the Invoice the AP Invoice will NOT post to stock. The stock posting was already done on the Goods Receipt.
    Most documents can be cancelled, either by basing a reverse documents or by cancelling. For every each one of them the quantities and accounts postings follow the logic of continuous stock.
    Goods Receipt PO -> Reversed by a Goods Return
    AP Invoice -> Reversed by an AP Credit Note.
    Please note that there are NO double entries anywhere when a document is based on another.
    I hope it helps.
    Jesper

Maybe you are looking for

  • Lightroom 2 quit unexpectedly - will not load

    I am receiving an error when trying to open Lightroom 2 on my iMac,  I have been using it ofr years with no issues, all of a sudden it won't open.  Last week I had a virus that was hijacking my email so I loaded a MacKeeper antivirus software and ran

  • PI E-filing GB SWCV Issue

    PI E-filing GB SWCV Issue I am currently experiencing an issue with E-filing in PI. We are getting various error messages from the message mappings... e.g.Target message Message Type: HR_GB_EFI_DPSrequestToken_Response does not exist in software comp

  • General question about webservices

    I hava a file "Test.java" (which attempts to test a webservice) and a XML-File. I compiled the Test-class successfully and now I'm wondering what are the next steps to be able to send a request to the webservice and get a response. I know that I will

  • MySQL syntax error with TestStand 4.0 database logging

    I had been using MS Access database to log results which worked fine but the access database is too limited. Switched to MySql. Database works fine and I can query it from Visual C++ and was able to create all my result tables fine from TestStand. I

  • Clear the selection screen

    In a report, after executing the program,  when the back button is pressed, the selction secren should not contain the previous value. Satis