Quality Management -- OS licenses

All,
My Customer has a question regarding their QM purchase--
They require  OS license (Windows Server 2003) and a SQL Server license (2005) for Quality Management.  We are currently deploying Windows Server 2008 and SQL Server 2008 for all new installations.  Are these more current versions of the software supported?  If not, when will they be?
Appreciate your help.
Thanks
Pratibha

Officially the documentation states WIndows 2003 and SQL 2005.  But our Cisco Engineer confirmed that Windows 2008 support was "just added".  Still SQL 2005 though.  But with Windows 2008 you'll need to manually install JTAPI (due to increased security).

Similar Messages

  • Licensing Issue Quality Management 9.0 with UCCX 8.5

    Hi guys,
    The UCCX compatibility matrix, Cisco WFO System config Guide plus QM 9.0 installation guide all state QM9.0 is compatible with UCCX 8.5(SU3).
    We have ordered QM9.0 licenses using part number
    L-CCX-90-QM-L-K9=:L-CCX-90-QM-L-K9= : CCX 9.0 Quality Manager Server , 10 Seats LICENSE ONLY
    I am unable to add these licenses to our UCCX server as I am getting:
    Error: The Cisco Unified CCX Quality Manager Seat feature (2nd line) of xxxxx.lic has unsupported version number (9.0)
    Has anyone installed QM9.0 with UCCX 8.5 and if so what licenses did you have to purchase?
    Thanks!

    I have not done this yet, I was looking into getting the license to do same you are doing.  Thanks for the heads up. I will wait to see outcome of your attempt.
    My main drive to go to 9.x is to get IE9 32 bit support with the latest 9.x SR as I have a handful of supervisors who have Windows 7 and using it to play back recordings, etc and I'm tired of the compatibility issues and time spent on their PCs to keep it running after they do other updates, etc.  Was hoping 9.x with the IE9 and 32 bit support would help with those headaches.

  • Cisco Quality Management 8.5 license error

    Dear networkers,
    After installing the Cisco Advanced Quality Management product (from DVD) and while configuring the "site configuration setup" and after clicking on next button; we face the following error message :
    "Invlaid License : The number of maximum users muste be greater than 0" (message attached)
    Can you please advice ?
    thanks in advance.
    Cdt.

    Hi haouaswajih,
    Please check the below errors,
    QMLC2003
    Text:The maximum number of user licenses must exceed zero for the bundle
    Type:Error
    Add’l Info:For the specified bundle, the maximum number of users licensed must exceed zero.
    Action:This should be configured by the system administrator.
    QM1015
    Text:Maximum number of users on the license bundle type {0} is zero.
    Type:Error
    Add’l Info:Maximum number of users on the license bundle type is zero.
    Action:Contact Cisco Technical Support.
    Reference:
    http://www.cisco.com/en/US/docs/voice_ip_comm/cust_contact/contact_center/workforce_optimization/qm_8x/reference/guide/qm852-ecd-cisco.pdf
    Hope this helps.
    Anand
    Pls rate helpful posts !!

  • Quality Manager no record the calls.

    Hi everyone
    I'm Deploying a Recording QM solution and it does't record the calls.
    I'm using a Network Recording enviroment with CUCM 8.6, CCX 8.5(su4) and QM 8.5.2.18
    I've followed the QM Configuration Guide and the CUCM monitoring a recording configuration guide to setup the QM. 
    Postinstall process was good, without any errors.
    Agents have basic license, and workflow is configured.
    I can see RTP packets coming from Agents pohones on call to Windows 2008 QM server using Wireshark.
    But any audio files is saves in the Recording folder.
    I have found some error in log files releated with SQL DB, But I checked the SQL information, and it is ok.
    I have attached a RecordSErver0001.dbd error as well.
    RecordSErver0001.log
    2014-03-23 23:00:14:348 INFO SL4007 The Windows NT service has started.
    2014-03-23 23:00:16:407 INFO SOCKET0000 <RecordService> service on port <59102> has started.
    2014-03-23 23:00:16:469 INFO MS0001 Socket service has been started.
    2014-03-23 23:00:19:932 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:00:23:630 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:00:51:959 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:00:55:657 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:01:24:017 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:01:27:699 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:01:56:075 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:01:59:757 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:02:28:118 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:02:31:784 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:03:00:176 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:03:03:724 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:03:32:131 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:03:35:766 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:04:04:158 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:04:07:808 INFO QM0001 Unable to retrieve 'recording storage location' with error '-1'.  Retries will occur automatically.
    2014-03-23 23:09:43:225 INFO STD0004 Client <Primary_CTI> connected to service at <10.10.10.5>.
    2014-03-23 23:27:01:859 INFO CTI0001 An error was received from the QM CTI Server for client with MAC address '': 'Provider Down.'
    ctiservice.log
    2014-03-23 23:04:44,578 INFO  QMCT0000 Server is listening at port <52102>.
    2014-03-23 23:04:50,022 INFO  QMCT0000 Opening JTAPI Provider Primary='10.10.10.2' Username='QM'...
    2014-03-23 23:04:52,471 INFO  QMCT0000 SQM CTI Service ready.
    2014-03-23 23:05:49,006 INFO  QMCT0000 Client Connected <10.10.10.5>
    2014-03-23 23:05:49,053 INFO  QMCT0000 Sending Response <10.10.10.5>: Head[26,158,1]InvokeId=1;StatusCode=0;StatusText=OK;StatusMemory=0,0439;StatusThreads=0,0033;<
    2014-03-23 23:06:14,590 INFO  QMCT0000 TimeoutTimer[HeartbeatTimer] Timeout Items=0 - FreeMem=4784304 TotalMem=16252928 MaxMem=259522560.
    2014-03-23 23:09:43,225 INFO  QMCT0000 Client Connected <10.10.10.5>
    2014-03-23 23:09:44,223 INFO  QMCT0000 Sending Response <10.10.10.5>: Head[26,158,1]InvokeId=1;StatusCode=0;StatusText=OK;StatusMemory=0,0446;StatusThreads=0,0033;<
    2014-03-23 23:09:44,239 INFO  QMCT0000 <Agent[type=Network,dev=SEP000C298D44C2,ip=10.10.10.5,id=1.PC2]> created successfully.
    2014-03-23 23:09:44,254 INFO  QMCT0000 <Agent[type=Network,dev=SEP000C298D44C2,ip=10.10.10.5,id=1.PC2]> registered successfully.
    2014-03-23 23:09:44,254 INFO  QMCT0000 <Agent[type=Network,dev=SEP000C290478A3,ip=10.10.10.5,id=1.PC3]> created successfully.
    2014-03-23 23:09:44,254 INFO  QMCT0000 <Agent[type=Network,dev=SEP000C290478A3,ip=10.10.10.5,id=1.PC3]> registered successfully.
    2014-03-23 23:09:44,270 INFO  QMCT0000 <Agent[type=Network,dev=SEP000C29B5DB52,ip=10.10.10.5,id=1.PC1]> created successfully.
    2014-03-23 23:09:44,270 INFO  QMCT0000 <Agent[type=Network,dev=SEP000C29B5DB52,ip=10.10.10.5,id=1.PC1]> registered successfully.
    2014-03-23 23:15:43,039 INFO  QMCT0000 Client Connected <10.10.10.5>
    2014-03-23 23:15:43,039 INFO  QMCT0000 Sending Response <10.10.10.5>: Head[26,158,1]InvokeId=1;StatusCode=0;StatusText=OK;StatusMemory=0,0476;StatusThreads=0,0033;<
    2014-03-23 23:27:01,859 INFO  QMCT0000 NT Service requested shutdown <QM CTI Server[Configuration[10.10.10.5:52102][30,3]][running=true]>
    2014-03-23 23:27:01,859 INFO  QMCT0000 Shutting down request handling...
    2014-03-23 23:27:01,859 INFO  QMCT0000 Server no longer listening on port <52102>.
    2014-03-23 23:27:02,124 INFO  QMCT0000 Request handling shutdown complete.
    2014-03-23 23:27:02,124 INFO  QMCT0000 CTI Service shutdown complete.
    2014-03-23 23:27:03,372 INFO  QMCT0000 VERSION INFO: <Quality Management - ctiservice>: Version <8.5.2.18>
    2014-03-23 23:27:03,372 INFO  QMCT0000 NT Service requested start.
    2014-03-23 23:27:03,856 ERROR QMCT2006 Cannot load configuration from Data API Service.
    2014-03-23 23:27:03,856 ERROR QMCT2000 Could not retrieve configuration <Cannot load configuration from DB.>.  Retry in <30000> ms.
    2014-03-23 23:27:33,886 ERROR QMCT2006 Cannot load configuration from Data API Service.
    2014-03-23 23:27:33,886 ERROR QMCT2000 Could not retrieve configuration <Cannot load configuration from DB.>.  Retry in <30000> ms.
    2014-03-23 23:28:03,947 ERROR QMCT2006 Cannot load configuration from Data API Service.
    2014-03-23 23:28:03,947 ERROR QMCT2000 Could not retrieve configuration <Cannot load configuration from DB.>.  Retry in <30000> ms.
    2014-03-23 23:28:34,008 ERROR QMCT2006 Cannot load configuration from Data API Service.
    2014-03-23 23:28:34,008 ERROR QMCT2000 Could not retrieve configuration <Cannot load configuration from DB.>.  Retry in <30000> ms.
    2014-03-23 23:29:04,054 ERROR QMCT2006 Cannot load configuration from Data API Service.
    2014-03-23 23:29:04,054 ERROR QMCT2000 Could not retrieve configuration <Cannot load configuration from DB.>.  Retry in <30000> ms.
    2014-03-23 23:29:32,758 INFO  QMCT0000 NT Service requested shutdown <null>
    2014-03-23 23:29:32,773 INFO  QMCT0000 CTI Service shutdown complete.
    dbproxy.log
    14-03-23 22:02:05,442 INFO  QMDP0000 VERSION INFO: <Quality Management - dbproxy>: Version <8.5.2.18>
    2014-03-23 22:02:05,442 INFO  QMDP0000 NT Service requested start.
    2014-03-23 22:02:05,894 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:02:05,894 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:02:35,924 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:02:35,924 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:03:05,954 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:03:05,954 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:03:35,984 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:03:35,984 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:04:06,015 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:04:06,015 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:04:36,045 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:04:36,045 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:05:06,075 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:05:06,075 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:05:36,105 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:05:36,105 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:06:06,135 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:06:06,135 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:06:36,165 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:06:36,165 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:07:06,195 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:07:06,195 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:07:36,225 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:07:36,225 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:08:06,255 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:08:06,255 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:08:36,285 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:08:36,285 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:09:06,315 ERROR QMDP2001 Unable to load database connection properties from Data API Service
    2014-03-23 22:09:06,315 ERROR QMDP2003 Could not initialize RequestManager. Verify DB connection information is correct. Will retry in 30000ms.
    2014-03-23 22:09:36,626 INFO  QMDP0000 Server is listening at port <52103>.
    2014-03-23 22:14:42,839 ERROR QMDB2001 SQM database execute failed: The INSERT statement conflicted with the FOREIGN KEY constraint "EventAudit_person_FK". The conflict occurred in database "SQMDB", table "dbo.Person", column 'id'..
    2014-03-23 22:16:06,845 ERROR QMDB2001 SQM database execute failed: The INSERT statement conflicted with the FOREIGN KEY constraint "EventAudit_person_FK". The conflict occurred in database "SQMDB", table "dbo.Person", column 'id'..
    2014-03-23 22:16:11,431 INFO  QMDP0000 NT Service requested shutdown.
    2014-03-23 22:16:11,431 INFO  QMDP0000 Server no longer listening on port <52103>.
    2014-03-23 22:16:11,431 INFO  QMDP0000 DB Proxy shutdown complete.
    mana.log
    2014-03-23 23:25:42,626 INFO  MANA0000 Running polling diagnostic...
    2014-03-23 23:26:01,799 ERROR QMMN2016 Unexpected error while getting call data for CM task.
    2014-03-23 23:26:01,908 INFO  MANA0002 Notification: <2014-03-23 23:26:01 QM1000 [CATASTROPHIC] Mana no pudo conectarse a Quality Management CTI Service (10.10.10.3): RECHAZADA>
    2014-03-23 23:26:01,908 INFO  MANA0000 Polling diagnostic finished.
    Any aideas?
    Thank you

    Did you ever get this resolved?  This product is horrible.  I fix one thing and then another is broken.

  • Quality manager Requirements

    One of our Customer is having Contact Center Express 10.x with HA. Number of Agents : 40 , Number of Supervisors : 20.  They have 60 CCX Premium License. Now they need to have Voice Recording Solution for All Agents.Need Help regarding this.
    1. What is difference between Call Recording and Quality Manager ?
    2. What is the Difference Between Quality Manager Base Server and Quality Manager Recording Server ?
    3. Both Quality Manager Base Server and Recording Server is mandatory ? OR Either of the one is only required and not both at the same time ?
    4. Can i Install Both QM Base Server and QM Recording Server inside one Single Windows server OS ?
    5. Can i install CCX Virtual Machine + QM Base Server ( Windows OS) Virtual Machine + QM Rec. Server ( Windows OS ) Virtual Machine in one single UCS Physical Server ?

    You buy QM Enterprise direct from Calabrio, and QM Express from Cisco.

  • Create Quality Management view for a Material in background mode

    I want to know if there is a way to create a Quality Management View (Quality Management tab) on Material Master (material already extended to plant ) in background mode.
    The requirement is to add inspection setup data for a material extended to a particular plant in background. I tried using 'BAPI_MATINSPCTRL_SAVEREPLICA' to add the data and it works perfect as required. Now the problem is this BAPI is creating the inspection setup data only for the material which has QM tab in MM02 for e.g. I manually created the inspection setup for a Material from MM01 and then deleted it , now the BAPI works fine for this material because when I created an inspection setup from MM01 it created the QM tab and after i deleted the entry the tab was still there with no entry in inspection setup.
    I want to create inspection setup for a material which does not have QM tab.
    I have to create everything is background mode. BDC is one option which I am list interested in.
    Thank you for helping in advance.

    Thank you for looking into my issue. I have to do the inspection setup in background without using any front end transaction.

  • Quality Management During Goods Receipt (Inspection Lot)

    Hi all,
    >>>>>>>>>>>>
    REQUIREMENT
    <<<<<<<<<<<<
    I have a requirement that i need to write an interface program which will receive a file from external agency (manufacturer) and process goods receipt until inspection results. The following steps need to be taken care of;
    1) Create a equipment (Utilities - It is an unique identifier for each unit of the material).
    2) Do Goods Receipt for the PO with the equipment numbers created.
    3) Create Inspection Lot for the material document created during the GR for each equipment number.
    4) Execute Inspection Result.
    >>>>>>>>>>>>
    INFO NOW
    <<<<<<<<<<<<
    Inspection lot can be created from MIGO directly by SPRO config and MM master data maintenance.
    >>>>>>>>>>>>
    DONE
    <<<<<<<<<<<<
    Called BAPI to create Equipment.
    Called BAPI to create Goods Receipt.
    Inspection Lot Settings to create lots during MIGO
    1) New Inspection Type Created as SG1 at SPRO->QM->Quality Inspection->Inspection Lot Creation->Maintain Inspection types. The maintenance is a copy of type 01.
    2) Assign Inspection Type to Lot Origin at SPRO->QM->Quality Inspection->Inspection Lot Creation->Maintain Inspection Lot Origins and Assign Inspection Types. SG1 is maintained against lot origin 01 with variant 01.
    3) Set Default values for SG1 at SPRO->QM->Quality Inspection->Inspection Lot Creation->Define Default Values for Inspection Type with parameters same as for 01.
    4) In Material master for the record set the inspection setup in the quality management tab. put SG1 as active and preferred. Also set Post to insp Stock, Insp with task list, Auto Assign, Skips allowed, Serial Numbers poss, Control Insp lot as For each Material Doc Item.
    I have to kow how to select the Inspection Plan for the lot and thus set the status of lot to released and get it ready for results.
    I also have BAPI ready for Inspection Result.
    >>>>>>>>>>>>
    TESTING
    <<<<<<<<<<<<
    I have tested it and was working fine till last thursday. I have the above mentioned settings even now in the system. Can there be anything else which the functional consultants would have change that affected the process. Anyways now the inspection lot is not getting created for the Inspection during MIGO and I am really struggling to find the exact reason.
    For your info, I am working mostly on Utilities and so do not have much idea about the quality management stuff.
    >>>>>>>>>>>>
    QUESTION
    <<<<<<<<<<<<
    Why the inspection lot is not getting created during MIGO for my scenarion?
    How to select the inspection plan in the program?

    deleted

  • Inspection setup in view quality management update in material master

    Hi all,
    We are using BAPI_MATERIAL_SAVEDATA for our material master updation.
    Here one  of the change in the program is to update the inspection setup in the view quality management.
    Can anybody tell in which stucture of the bapi BAPI_MATERIAL_SAVEDATA  i can pass the values of the inspection set up fields.If not is there any other bapi through which can be done?
    Thanks in advance.
    regards
    Nazmul

    Hi,
    To deactivate the Inspection Types for materials, you can use transaction QA08.
    Here use tab "Deactivate insp. type" and specify the inspection type which you want to dactivate.

  • Quality Management v9 - Recording file is .spx and size of 0 kb

    Guys,
    I have theses versions here :
    CUCM v9.1.2
    Quality management 9.0.1.57
    UCCX 9.0.2.11001-24
    Desktop are connected on the PC port of the phone !
    I want to do the desktop recording and I have an issue where the storage location contains only .spx files that are empty with 0 bytes.
    Here is the troubleshoot I did :
    From the Recording interface I can see all the conversation but I can't play it.
    If I use wireshark I can see the RTP on the destop, I can convert it and listen that RTP stream..so the stream is going to PC
    If I run the QMDump on the desktop of the agent I see the G711 Ulaw which is good but I can't find Skinny hearts beats ( logs of QMdump Attatch ).. I rebooted the phone but still..
    I see on the troubleshooting guide, that this situation could be during the conversion process, it says we need to get logs and escalate the case.
    Anyone have a suggestion ?

    Mary,
    this issue pertains to either not receiving a SIP invite to start recording, or not receiving the actual RTP from the phone.  More than likely it is not receiving a SIP invite.  Check the (WFO 9.0 "Recordserver.dbg") or (WFO 10.0 "Ctiservice.dbg") logs , look for INVITE, it should tell you if you received it or not.
    Example of a good SIP invite:
    SIP: IN|INVITE sip:[email protected]:5060 SIP/2.0|6156255c|10.192.252.36:32880->10.32.2.66:5060|Call-ID: [email protected]|From:
    Example of a BAD SIP response:
    type=Network Recording,person=140]] call CiscoCall[Call[2:20211600];ConnectionId=31651532] should have received SIP but didn't!
    If you are getting a SIP invite, then check the ports between Phone and Recordserver to ensure RTP can get through.
    If you are NOT getting a SIP invite, check your CUCM configuration for Recording:
    here is a link to guide you.
    http://www.cisco.com/c/en/us/td/docs/voice_ip_comm/cucm/admin/6_0_1/ccmfeat/cmfsgd601/fsmr.html#wp1047595

  • Is Quality management module required to be used for vendor evaluation?

    Hi,
    There is vendor evaluation functionality in MM. Is use of quality management module is mandatory for this? I wish to track the performance of vendor regarding quality (How much he has supplied, out of which how many are accepted and how many are rejected). Can I get this report without using QM?
    Thanks in advance,
    Satish

    you can enter Quality results manually in vendor evealuation, so QM is not necessary for this, however with QM you can get the scores semi-automatic and  automatically.

  • Function module for Mass uploadnotifications in Quality Management

    Hi  Experts,
    I need function module for quality management which MASS UPLOAD THE QM NOTIFICATIONS.
    Thanks

    Hi,
    For updation use BAPI_QUALNOT_ADD_DATA.
    Hope it helps.
    Regards
    Hiren K.Chitalia

  • SAP TechEd 2011- Data Integration and Quality Managment Sessions

    Looking for answers on "Data Integration and Quality Management," check out the related educational sessions at SAP TechEd 2011 ([Las Vegas|http://bit.ly/qE0dZs], [Bangalore|http://bit.ly/oVdGsM], [Madrid|http://bit.ly/rnSNOT]). [Register today|http://www.sdn.sap.com/irj/scn/sapteched]!

    Hi,
    you must check in sap teched site and register it, the link as below
    [SAP Teched Banglore 2011|http://www2.sapevents.com/SAP/TechEd2011Bangalore/index.cfm?fuseaction=agenda.sessionCatalogueHOS&view=overview]
    Thanks,
    Jansi

  • ADD On of Quality Management

    whr i can find Add on on Quality Management
    Quality Management
    Quality Planning       Need Addon
    Quality Notification          ""
    Quality Inspection (Raw materials in Procurement and Finished products in Production)   "",
    Test Equipment Management

    Hi,
       For Test Equipment Management here is the link for SAP library:
    http://help.sap.com/saphelp_nw04/helpdata/en/2d/352209448c11d189420000e829fbbd/frameset.htm
    For quality notification.
    http://help.sap.com/saphelp_nw04/helpdata/en/8d/3e6143462a11d189000000e8323d3a/frameset.htm
    Hoping this might help you in your query.
    Have a best day ahead.

  • Control Key for Quality Management in Procurement

    if we activate Control Key for Quality Management in Procurement in material master then wether we need  also store a control key at the plant level for quality management in procurement.
    if we want want to maintaine
    pls tell me how it is
    pls expalin
    faisal

    if we activate Control Key for Quality Management in Procurement in material master then wether we need also store a control key at the plant level for quality management in procurement.
    I am not clear about your question. But I guess you want to know about control key function. You activate "proc. asctive" box in QM view of material master, that is always at plant level. When you activate this, system automatically asks for a control key & cert type, thats mandatory field.

  • Warehouse Management (WM) Quality Management Interface

    When receiving materials into quality management from a purchase order the system automatically puts the material into the interim bin 902.   Is it possible to configure the system to automatically create the transfer order (and select the putaway bin) from the Quality management usage decision - moving the material from 902 to the put away bin?  The materials management movement type is 321.

    whenever you recieve material from external supplier, then it goes to 902, this has nothing to do with the stock status.
    At the same time you usually get a transfer request to move the material to the bins.
    When your quality inspection is done, then this will create a so-called posting change notice with a positive quant in urestricted status and a negative quant with Q status, both in storage type 922.
    It does not really matter if your q-status quantity is still in 902 or already in the final bins, when you process the posting change notice in LU04, except you are moving the postive quant manually from the 902 zone and issue already material.
    Both, the automatic creation of TOs for the transfer from 902 to the bin as well as the processing of the PCN can be automated.
    Background jobs are  RLAUTA10 and  RLAUTA11

Maybe you are looking for

  • SCCM 2007 and 2012 coexistence and Cross Forest support

    Hi All I have a question My company has recently acquired another company That company exist of 2 forests (forest A has one domain namely domain A : and forest B has one domain namely domain B) with a two way forest trusts between them Domain A has a

  • How can I show or hide an image based on screen size in CS6?

    I have a web site built using Dreamweaver CS6. I used the fluid grid layout to have different views for each of the 3 types - phone, tablet, desktop. It works well, resizes as it should. I would like to be able to show an image in the desktop version

  • Batch management AR-Invoices.

    Hi everybody, How can I do, when I create an AR-Invoice, to select the  material batches, with an specific criteria? Because the system only permits me take batches in secuencial order

  • Cannot unzip .zip even with Archive Utility

    Hi, I have problem unzipping a .zip file. When I use the Archive Utility to unzip it, it yields a file with the same name with .zip.cpgz on its end. When I subsequently make another trial - to unzip this new file, it yields the very same file only wi

  • Variant problem for 2 ALVs

    hi i have 2 alv's in 1 screen. if i save a layout variant in one of the ALVs, the same shud be applied to 2nd alv also and the screen shud refresh & display with the new variant. how can i do this? tx kiran