Quantity available to putaway in a storage bin

Experts,
Is there any way to find the quantity we can putaway in a storage bin? i.e say 50 more pc can be putaway on a storage bin.
regards,
James....

Jürgen L.
Thanks for your quick reply.....
Let me explain more detail.
I have created a new storage bin with a maximum storage weight as 10000Kgs. And some TO has been created for putaway on the bin with 1500kgs. And now the occupied weight of the storage bin is displayed as 1500kgs.
I want to know the remaining amount/qty of material I can putway for this particular material? Is it equals to 10000 - 1500 = 8500kgs ?
And also I want to find the list of materials can be stored on a storage bin. i.e what are all the materials we can store in a particular storage bin. 
Thanks!
James

Similar Messages

  • Putaway Block in Storage Bin for any specific Material Code

    Hi Experts,
    We have a problem, we have allowed mix storage, addition to stock in the storage type, our requirement is this, that we want to block one bin aa-01-01 for some specific material code xxxxx, but we want to allow putaway other material codes to that bin.
    How can we achieve this. Can we use LS07 or some other solution. Please suggest at the earliest.
    Regards
    Ishu

    Hi,
    In standard system, you can block one specific bin for the specific material with Putaway strategy "Fixed bin" by maintaining this bin in material master. It is unclear that you set "allowed mix storage" and again required material specific putaway in bin.
    You can change "Mixed storage" indicator to blank. Which explains "___"  Mixed storage is not allowed
           All storage units in a storage bin must contain the same material and batch (one quant).
    If you don't want to change any of current setting you'll need to use the user exit and maintain custom table where you can maintain specific bin for the material for the warehouse. After determination of the bin to putaway in the standard code you can check if it is conflicting to the entry in your custom table.
    Hope this'll help.
    Regards,
    Sudhir

  • Storage bin issue -

    hi friends
    storage bin 01-01-01 stock is 1000 quantity...After PO-GRN all stock is updated in same storage bin  01-01-01...
    my querys is i want to fill 100 qty should be filled in 01-01-01 storage bin , if quantity excess means remaining quantity should be
    fill in another storage bin 01-01-02  ...
    where is the control in wm
    pls helpme for this issue
    with regards
    dinesh
    Edited by: code acess on Jun 13, 2011 12:42 PM

    HI FRIENDS
    I Have the issue, PO order quantity 5000 number. i did GRN.iam trying to do transfer order ..system is update the stock 1000 qty is
    updated  01-01-01.. system is automatically remaining quantity 4000 is updates in return stock bin in transfer order..i want to 1000
    qty should be updated in 01-01-01 and remainin quantity should be update the sequence of BIN Like  01-01-02.
    where i made mistake the configuration....
    pls suggest me
    with regards
    dinesh
    Edited by: code acess on Jun 14, 2011 8:51 AM

  • Error storage bin

    movement type 311
    tcode mb1b
    from sloc 00
    to slco  01
    quantity  20 pc
    error is coming storage bin Z1 not found
    settings i have done in warehouse
    in 311
    destination storage type   :  921
    in material master  :  stock placement (maintianed)
                                    stock removal (maintianed)
                                   storage section (maintianed)
    search atrategy  for storage type (maintained for high rack and goods are to be removed from here )
    search strategy removal and Putway BOTH ARE MAINTAINED FOR HIGH RACK AND SHELF STORAGE
    Edited by: Rahul Tyagi on Feb 12, 2008 11:56 AM

    i have created 4 storage types  IN my warehouse Z1 and asigned this Z1 to plant and sotrage location SLOC 00 & SLOC 01 in spro>ep>assignment>le
    now both the sloc are assigned to the same warehouse that is z1 so it means boththe sloc have same sotrage area avilable
    goods are lying at high rack(storage area) for sloc 00
    in material master storage indictor for stock placemnt mentioned sz1
    entry in storage type seach is like this
    Z1(WH)   E(STOCK REMOVE)    ZSI(STORAGE TYPE INDICATOR)     HIGH RACK (STORAGE TYPE)
    FOR STOCK REMOVAL ENTERYS ARE IN STORAGE TYPE SEARCH LIKE THIS
    Z1(WH)   A(STOCK PUTWAY)         ZRI(INDICATOR FOR STOCK PUTWAY)       SHELF STORAGE
    I HAVE ALSO CREATED THE STORAGE BINS FOR ALL THE STORAGE TYPES
    AND POINT TO NOTE IS Z1 IS NTO A BIN ITS THE NAME OF WAREHOUSE  
    IF ASSIGN INTERIM STORAGE AREA IN 311 N FIELD SOURCE THEN IT WORKS FINE
    BUT IF I ASSIGN INTERIM AT DESTI THEN THE ERROR COMES AS GIVEN IN THE VERY BEGI.
    AND THE RIGHT WAY IS TO ASSIGN THE SINTERIM IN THE DEST. IN 311
    PLEASE SUGGEST THE SOLUTIONI CAN ALSO SEND U THE SCREEN SHOT IF U CAN PROVIDE U RMAIL ID (IF IT IS POSSIBLE FOR U)
    Edited by: Rahul Tyagi on Feb 12, 2008 12:08 PM

  • Putaway quantity does not show in Interim Storage Type 916

    Hi all,
    It could be a silly quesiton however would need your help with the issue below.
    When I create Picking TO from Outbound Delivery, usually I will see the Pick Quantity from Source Storage Bin and Putaway Quantity showed in Interim Storage Type 916. However, for the warehouse I'm working on I could not see the Putaway Quantity showing in Sty 916, only Picking Quantity displayed from source storage bin.
    For example, I created picking TO# 17439 to pick stock from storage type 001 to destination storage type 916. Here I only see the 'Pick Quantity' showing in storage type 001. I don't see 'Putaway Quantity' shows in Storage Type 916.
    Would appreciate if anyone can provide some advices. Thanks.
    Khanh Ngo

    Hi Jurgen, I have cancelled the TO above for some other tests. I have created a new delivery, please see the new TO#17442 with LT21:

  • Storage bin available when posting change is not confirmed completely

    Dear Gurus, I have a question for you:
    My costumer wants to do a posting change when the material is released from QM with a decision usage from Q to unrestricted use. The process is done in two steps: with LU04 the TO is generated and with LT12 is confirmed. When the TO is generated the position is half confirmed. With LT21 we can see the row for the ST (lets say ST 504 Open Storage type) and a second row 922 TR-ZONE. The first row appears green (as confirmed) and the second row appears red (Not confirmed).
    My costumer says that " beacause of the strategy given for the storage entry, the storage bin released in the TO (not confirmed completely yet)   is available at this moment.
    If the storage bin is still physically full, the carrier will found not space for leaving the goods even SAP is telling him there is space available at this storage bin."
    I have read that once yo start a TO the storage bin is blocked until the transaction is fully confirmed.
    If this is correct I need to demostrate it and I don not find the way to do it.
    I hope you understand my explanation and give me any clue.
    I appreciate very much some help.
    Al

    agmogena wrote:
    Ok, I will tell you the configuration I have. Lets point in a movement 921 quality to unrestricted use.
    > Type Storage origin: 902  EQ and RC flags are set on. (confirmation control for storage type)
    > Type storage TR: 922 are set on.
    >
    > Movement type 921 the flags for Confirm immed and Propose confirm are NOT set.
    >
    > I do a LU01 to create a intruction to change a material from Q to Unrestricted.
    > with LT05 I create the TO.
    > At this time if I look LT21 the TO created I see the tag source with two positions one for TS 902 green color and the second 922 in red.
    > For the tag of target We can see the first position 922 In red and the second position 902 in green color.
    >
    > Perhaps this detailed explanation will help you to fully understand the scenario.
    >
    > Thank you again,
    >
    > Al.
    From the above it isn't entirly clear that the first part of the T.O. is actualy confirmed, my settings are to autoconfirm this so I have no example to look at in my system. Perhaps the display shows the first line green before any actual confirmation..
    I assume the stock status has not changed when you first view the T.O.? If the t.o. is partly confirmed I would expect to see the stock status changed and a neg in 922 until the second part is confirmed. Perhaps there is no confirmation at all yet, in LT21 what is the confirmation status? If you view the transfer order header there would be a partial confirmation showing with a yellow triangle, do you see this or no confirmation indicated at all?

  • Available stock shortfall of & in Interim storage bin message in BAPI_GOODSMVT_CREATE

    Hello Abapers,
    I have created a Zprogram and used a standard function module BAPI_GOODSMVT_CREATE.
    while processing this FM, Iam getting error messages in return table as "Available stock shortfall of & in Interim storage bin".
    Please help or suggest.
    Regards
    Pradeep

    Searching on the forum you can find threads about WM/PP interface settings.
    (Re: WM Staging - Supply area to Production prder)
    Whether WM/PP interface is active it depends on your config and master data as well.
    You should check:
    - config: SPRO > LE > WM > Interfaces > Define Production
    - master data: routing (proper work center is assigned), work center (proper production supply area), material master(FG) (production scheduling profile), control cycle (components)
    In standard system storage type 100 is defined as an interim storage type (you can compare it to storage type 902, 914, 916, etc). In control cycles (WM master data; LPK1/LPK2/LPK3) you define for each components which is the production storage type.
    In standard system storage type 914 is not used with material staging. 914 s.t. related scenario: GI (261) --> stock removel from normal storage type to interim storage type (914).
    100 s.t. related scenario: stock removal from normal s.t. to interim s.t. 100 --> GI (261).

  • Available stock in interim storage bin

    Dear all
    I Create GR Returns 161 with MIGO, I have message error
    "50012541 ; available stock in interim storage bin around  1,000.000 KG below target
    Message no. L9040
    Diagnosis
    In Customizing, the setting is such that no negative stock is allowed in storage type 916.  However, this posting will cause negative stock to exist in storage bin 0000000000 of storage type 916. "
    Can anyone help me ?
    thanks
    imron

    Dear
    I created cutomazing in Spro>Logistic Execution>Warehouse management>Activities>Transfer>Define Movement types :
    - Movement Type  = 161  (Returns PO)
    - Dest                  = 916
    - Shipment Type   =  A (Stck removal)
    - Requirement type =    B Purchase Order
    - manual TO creation not allowed
    - manual TR creation not allowed
    And then I created TO with LT01 using move type 161 and requirement type = B
    Now stock in Storage Type 916 was there with qty 1000
    But When try again to Create GR (MIGO-161- PO return)
    the error still  "50012541 ; available stock in interim storage bin around 1,000.000 KG below target
    Message no. L9040
    Diagnosis
    In Customizing, the setting is such that no negative stock is allowed in storage type 916. However, this posting will cause negative stock to exist in storage bin 0000000000 of storage type 916. "
    Can u help me, please
    thanks

  • Auto-copy putaway quantity in Inbound for Non-WMS storage location

    Dear All SAP Gurus,
    I need to create an inbound delivery document for non-WM managed storage location and "copy" the quantity into the "putaway quantity" field automatically. Is there any setting to do this automatic assignment? As far as I know, if the storage location is non-WM managed, we usually need to manually enter the putaway quantity as part of the verification process during the PGR (goods receipt).
    Please help.
    Thank you and appreciated for your efforts.
    Best Regards,
    Edwin

    Dear All,
    Before this, I can't find any similar topic posted before, perhaps I was using an incorrect/not-so-meaningful keywords (although I've tried a lot of keywords). However, I've finally found the same topic in the following link. Anyone who is interested, may proceed to the following link.
    Re: Regarding Automatic Picking Setting in Deliveries
    Regards,
    Edwin Fu

  • Available stock shortfall of & in interim storage bin

    Hi gurus,
    I am doing the movement type 261 in MIGO with reference to a reservation.
    I am working with Warehouse Management and I want to know why the system is defined in automatic the storage type 100?
    When I am doing the movement 261, I know that I have stock in the storage type 007 and I am putting this, but, the system is showing the following error message:
    100000000026; Available stock shortfall of         10.000 M2 in interim storage bin
    Message no. L9040
    Diagnosis
    In Customizing, the setting is such that no negative stock is allowed in storage type 100.  However, this posting will cause negative stock to exist in storage bin HE01 of storage type 100.
    For my storage type 100 I do not have defined any strategy in the customising.
    Could you help me with this, please?
    Kind regards.
    SP

    Searching on the forum you can find threads about WM/PP interface settings.
    (Re: WM Staging - Supply area to Production prder)
    Whether WM/PP interface is active it depends on your config and master data as well.
    You should check:
    - config: SPRO > LE > WM > Interfaces > Define Production
    - master data: routing (proper work center is assigned), work center (proper production supply area), material master(FG) (production scheduling profile), control cycle (components)
    In standard system storage type 100 is defined as an interim storage type (you can compare it to storage type 902, 914, 916, etc). In control cycles (WM master data; LPK1/LPK2/LPK3) you define for each components which is the production storage type.
    In standard system storage type 914 is not used with material staging. 914 s.t. related scenario: GI (261) --> stock removel from normal storage type to interim storage type (914).
    100 s.t. related scenario: stock removal from normal s.t. to interim s.t. 100 --> GI (261).

  • Putaway-P & storage BIn clarrification

    Hello Friends,
    Am new to WM, can you pl help me in understanding the below scenario's??
    Say We have 2 materials, MATERIAL-X & MATERIAL-Y.
    Will assume ABC as storage type with putaway strategy say" P" - Storage unit type , and bin capacity is 20.
    Scenario: 1
    On 15.10.2010 we received MATERIAL-X  = 10 qty, and moved to storage bin XYZ
    On same day on 15.10.2010 we received another MATERIAL-Y =10 qty.
    can we send MATERIAL-Y to bin XYZ?
    What is the config required in storage type for moving it to same bin or to next bin?
    Scenario: 2
    On 15.10.2010 we received MATERIAL-X  = 10 qty, and moved to storage bin XYZ
    On same day another consignment received 15.10.2010 same material MATERIAL-X  = 10 qty,
    Can we move MATERIAL-X to bin XYZ Bin?
    What is the config setting required for moving to same bin or to another bin?
    Scenario: 3
    On 15.10.2010 we received MATERIAL-X  = 10 qty, and moved to storage bin XYZ
    on 16.10.2010 same material MATERIAL-X  = 10 qty,
    Can we move MATERIAL-X to bin XYZ Bin?
    What is the config setting required for moving to same bin or to another bin?
    Regards
    Suresh

    Hi,
    It depends upon strategy maintained for storage type ,check in config. what strategy you have maintained for particular storage type where material will be stored.

  • Dest.storag bin change during putaway foreground in LT04

    HI
    For creating TO from TR , we run LB10, and select "TO in foreground", open (LT04), when we create TO (LT04 ) - on first item, we select "Putaway foreground" (icon >lifter with plus sign), shows Palletization screen, here system automatically purposes, 
    Destination storage type, storage section and storage bin.
    also purposes quant, storage unit .
    Here (in the same screen) can we change destination storage section(allowed) and bin(allowed) ?
    Storage type setting:
    Putaway strategy is : I > addition to existing stock
    Destination bin change during confirmation = 1  allowed  ( i understand , it means we can change distination storage bin during TO confirmation )
    Secondly, i know we can enter storage type, section and bin in LT04 main screen, and go to "Palletization".
    it purposes remaining elements like Quant, storge unit.
    thanks
    james

    Hi All
    question is
    CAN we change destination storage section and storage bin   on  " PUTAWAY FOREGROUND" screen ( that comes on clicking icon Lifter Plus sign) , where system purposes \ recommended based on master data defined for that material .
    I know we can change it on LT04 , main screen . and its working.  my focus is , "Putaway foreground" screen is more appropriate for changing sections or bin.
    i have carefully configured storage types setting, material master , storage indicator , section indicator , Storage unit type, Storage bin type etc.
    thanks
    James

  • Dest.storag bin change during putaway foreground

    HI
    For creating TO from TR , we run LB10, and select "TO in foreground", open (LT04), when we create TO (LT04 ) - on first item, we select "Putaway foreground" (icon >lifter with plus sign), shows Palletization screen, here system automatically purposes, 
    Destination storage type, storage section and storage bin.
    also purposes quant, storage unit .
    Here (in the same screen) can we change destination storage section(allowed) and bin(allowed) ?
    Storage type setting:
    Putaway strategy is : I > addition to existing stock
    Destination bin change during confirmation = 1  allowed  ( i understand , it means we can change distination storage bin during TO confirmation )
    Secondly, i know we can enter storage type, section and bin in LT04 main screen, and go to "Palletization".
    it purposes remaining elements like Quant, storge unit.
    thanks
    James
    Edited by: Csaba Szommer on Jan 6, 2012 8:10 AM

    Hi All
    question is
    CAN we change destination storage section and storage bin   on  " PUTAWAY FOREGROUND" screen ( that comes on clicking icon Lifter Plus sign) , where system purposes \ recommended based on master data defined for that material .
    I know we can change it on LT04 , main screen . and its working.  my focus is , "Putaway foreground" screen is more appropriate for changing sections or bin.
    i have carefully configured storage types setting, material master , storage indicator , section indicator , Storage unit type, Storage bin type etc.
    thanks
    James

  • More than one Quant in a Storage bin section (Strategy P)

    Dear all,
    We have a Storage type with Putaway strategy P, the SUT check active but no SU Management active, Mixed storage = X and Addition to stock = X.
    For this Storage type, our Storage bin type and SUT we have set up in customizing a Bin sectioning 3 meaning the Storage bin is divided into 3 sections so a maximum of 3 Quants per Storage bin. Note that other Bin sectionings have also been set up.
    During testing I found out a Storage bin section can only contain one Quant at a time.
    Because of Addition to stock = X we can add more quantities of the same Material/Batch to a Storage bin secion that already contains stock of this particular Material/Batch.
    If I try to add a Material/Batch to a Storage bin section that already contains stock of another Material/Batch (so, a different Quant), the system gives me an error:
    Bin item X in storage bin Y already occupied
    Message no. L3063
    Now physically for the mentioned SUT our Storage bin is divided into 3 Storage bin sections/pallet places and on a pallet it should be allowed to put multiple Materials/Batches at a time, that is why we set Mixed storage = X in customizing.
    Now we can only put one Quant (so one Material/Batch) in a Storage bin section at a time;
    We want to be able to put more Quants into a Storage bin section at a time.
    How can we achieve this?
    Note we rather donu2019t want to use Storage Unit Management.
    Thanks for any clues!
    Kind regards,
    Bart

    Hi Bart,
      As a thumb rule you cannot have one quant with multiple Materials. Ofcourse you can keep on adding same material /batch is the same quant i.e. in the same Bin section where you already put the material.
    Quick win for your case is Increase the number of quants allowed say 15. In this case you can keep on storing different material / batches on the same pallet but system will keep on generating sections.
      At any point of time you can easily track how many quants (Mat + quantity)  are stored in that Bin & relevant section.
      For strategy P , SUT check must be activated you cannot skip it.
    If Business is not ready to work with more number of sections , you can always think of mapping another startegy ..you could do more test with Bulk Storage.
      To my knowledge Strategy I i.e. Addition to existing stock with Mixed storage Indicator will work very well here.
      You just need to map appropriate Capacity check as startegy I goes with active capacity.
    Thanks,
    Mahesh

  • Report to see the value of material at storage bin level

    Hi,
    The requirement is to see the quantity and value of material stored at storage bin level.
    Is there any standard report available to see the same.
    thanks

    Hi,
    Check on it:-
    Storage bin should display in MB52
    pherasath

Maybe you are looking for

  • Does GTC generate default value for Password attribute.??

    I am using GTC as trusted source reconciliation. My doubt is if I don't map the password attribute does it generate default value to the password attribute in user form?? I have a random password generator in pre-insert, first i tried as below which

  • I have Windows 98 and need Acrobat to open up the pdf files for 5.0

    I have the old system, Windows 98 and presently have the free Adobe 5.0 version on my Compaq Presario Computer, and it is a 5242 model desktop. I have inadvertanly switched over to Compaq Carbon Copy 32 Version 5.0 but since, have uninstalled it and

  • Ipod screen on while connected to mac

    Screen stays on when connected to my mac, seems to prevent it from getting a full charge. If I eject ipod and leave connected, the screen dims, then it will charge. Is this normal? I wish the screen would dim, I use it as a external disk too.

  • Itunes missing remote speakers airport express

    I have windows xp & itunes. When I updated to itunes 7.1 my remote speakers were missing and i am unable to retrieve them.

  • Ask the Expert: Cisco Prime Infrastructure - Implementation and Deployment

    Welcome to the Cisco Support Community Ask the Expert conversation. This Ask The expert Session will cover questions spanning Cisco Prime Infrastructure on Implementation and Deployment on Wired and Wireless. This will be more specific to Customer’s