How do I select quarter bridge completion settings for 9237 with 9944?
Message Edited by Frederico Barros on 09-28-2007 09:02 AM

The 9237 is capable of full and half bridge measurements without addition equipment. In order to take quarter bridge measurements with the 9237 you need a quarterbridge completion resistor component (like the ni 9944). This turns your quarterbridge configuration into half bridge, which the 9237 can do. You will need one of these completion components for each of your strain gauges.
[will work for kudos]

Similar Messages

  • How to connect 2-wire strain gage to NI 9237 by quarter bridge

    I have a Strain Gage: KYOWA KFG-20-120-C1-11 (2 wire) http://www.kyowa-ei.co.jp/english/products/gages/pdf/kfg-01.pdf, NI 9237 on a Compact DAQ (cDAQ 9174) and RJ-50 (10-pin modular plug to pigtail wires).
    Strain Gage features:
    Gage Factor: 2.08 +/- 1.0%
    Gage Resistance: 120.2 +/- 0.2 Ohms
    I'd like to connect them to measure the strain with quarter bridge configuration but I have some doubts about which line goes to which terminal.
    Thanks.
    Solved!
    Go to Solution.

    You can find the manual for the NI 9237 module here
    It's a good idea to buy an NI 9944 or NI 9945 Quarter Bridge Completion Accessory if you're planning on using this module with a quarter bridge configuration, but  you can look at the following diagrams to see what kind of internal connections are implemented: Connecting Strain Gauges and Shunt Resistors to the NI 9237
    PS Posting in the DAQ or signal conditioning forums instead of Labview may get you better/faster answers. 
    Cheers
    Message Edited by mishkin on 03-11-2010 02:40 PM
    Misha

  • Selecting bridge type for 9237 module on cRIO

    How do you select 1/2 or Full bridge completion and Shunt settings for 9237 Bridge module on cRIO? The getting started example only seems to set the data rate?. The FPGA Property Node only has Data Rate, Excitation, and ID params available as choices? Am using 8.2.1. Other discussion threads talk about configuring with MAX but for cRIO/8.2.1 MAX doesn't show modules, just the remote system top level.
    Thanks,
    Bruce

    Hi Bruce,
    The Half vs Full Bridge as well as the Excitation Voltage settings live in the properties page for the NI 9237 module in the LV Project (right-click module item>>Properties). See attached image.
    JMota
    Attachments:
    9237 properties page.JPG ‏36 KB

  • Correct Choice of the QUARTER Bridge Type

    Hello,
    We have to measure 80x SG (strain gauge) channels with 20x NI-9237 modules in 3x cDAQ-9188 chassis. The CEng guy wants to use a passive SG for temperature compensation in all channels (although not needed because we use self compensating SGs in their temperature range). So he will glue the active SGs on the tested model, and he will glue the passive SGs on pieces of same material AWAY FROM THE MODEL - NO THERMAL CONTACT WITH THE MODEL!
    This configuration for me is QUARTER Bridge Type 1 since the passive SGs (dummies) are just resistors unaffected by the seismic activities on the model.
    However, he insists on Type 2 guided by its definition ("Strain Gauge Configuration Types" Tutorial) which sounds like his comprehension of his bridge. I stay with Type 1 because the dummies are not in a close contact to the tested model - I see them just as bridge completion resistors.
    Can someone with expertise in SG conditioning and measurements help in solving this dilemma?
    Thanks in advance,

    OK, let me paraphraze my questions.
    1. RemoteSensing
    NI-9237 documentation says RemoteSensing is meant for HALF and FULL bridges, and for QUARTERs we should use shunt calibration. Since I plan to use Q2 which is not a HALF bridge will RemoteSensing be performed by the NI-9237 or not? If NOT, will measuring lead resistance do the job instead? I find it very awkward that this crucial info is missing from the NI-9237 documentation!
    2. Brdge balancing
    NI-9237 documentation says this module needs to know the "initial voltage" measured on disconnected ETERNAL part of the bridge to compensate for offset. I have used the "DAQmx Perform Bridge Offset Nulling Calibration.VI" to balance all my bridges in COMPLETED status prior to any acquisition. Is this doing the job so I do not have to measure the "initial voltages"?
    The tasks of interest are the 3x cDAQ. The PXI task needs some IEPE current sources to be switched on for 60sec prior to the acquisition so that the PCB accelerometers can be initialized.
    Thanks in advance,
    Attachments:
    SaveNullsFile.png ‏57 KB

  • SCXI 1520 quarter bridge setup will not output excitation voltage, but full bridge will

    My SCXI system will not output an excitation voltage to the quarter bridge(verified with voltmeter). It works for a full bridge setup. When connected to a 'quarter bridge I' configuration, I can use MAX to null and shunt calibrate. The quarter bridge circuit appears to be balanced after the calibration, but the calibration results post a software gain factor close to zero, as well as a close to zero excitation voltage (eventhough I have the voltage configured for 5 volts). I have the SCXI 1520 module, the virtual channels, and the wiring properly configured (several years experience with this device). I'm using an old E series DAQ card AI-16XE-50, with the 50 pin cable that plugs in the back of the SCXI chassis. I noticed I had two bent pins with the cable connector module that plugs into the SCXI backplane.  I was able to straighten them, so the cable connects properly, but I suspect the bent pin incident caused electrical circuit damage. Any suggestions on trouble shooting? None of the three 1520 modules I have will output an excitation voltage for a quarter bridge.

    Sorry that I don't have an answer for you tyea, but I'm interested in your thread because I have a similar issue with a 1520. My excitation votltage, as measured with a DVM, is always 1V. I've tried 0V, 1V, 5V --- it's always 1V, on Full or Quarter bridge. I'm using a similar DAQ to yours - a PCI 16XE-10 (and a PCI-6030E on antother system).
    I don't have a lot of experience with these modules. This could be a wiring or programmatic thing I'm doing wrong.
    Richard

  • How do I wire my SCXI-1520 quarter bridge completion in parallel?

    I have a quarter bridge set-up using the qtr completion in the system. In parallel with my strain gauge I'd like to have another resistor. I'm using the strain gauge as a dummy, and am interested in the current traveling in a parallel path through a film resistor as I change the film thickness. However, I'm not convinced that what I've wired has the strain gauge and other resistor in parallel. I have the strain gauge wired to: P+, QTR, S+ and the other gauge wired to QTR, S+.
    Thanks!

    Greetings,
    You will want to wire the other gauge between P+ and QTR or between P+ and S+. To make this decision, you will need to determine how the lead resistances will affect your measurement. Page 2-4 of the SCXI-1520 User Manual (link available below) contains the wiring diagram for Quarter-Bridge Configuration I.
    SCXI-1520 User Manual
    Good luck with your application.
    Spencer S.

  • How do I connect 16 strain gauges in quarter bridge arrangement to a SCXI 1322 connecter block?

    Specifically, do I connect 4 bridge completion resistors to each VEX- channel or do I need to wire them together somehow first?

    I have attached a bitmap image that explains how to wire a quarter-bridge strain gauge to the SCXI-1122 (with 1322 terminal block.) The 1122 only provides half-bridge completion, so you have to wire an extra resistor into the circuit to complete the bridge.
    You can find this image in the SCXI-1122 User Manual, which is available for download at:
    http://search.ni.com/search/query.html?col=alldocs&qp=%2Bcontenttype%3Aproductmanual&lk=2&layout=ProductManual&qt=1122
    Attachments:
    1122_strain.bmp ‏920 KB

  • Detailed Software Repair Instructions using Pc Companion(Win)or Bridge for MAC. (Update 8/5/2014)

    We have an extended guide that should help you repair the system of your phone. This instructions are valid for all Android based units and for some legacy Sony Ericsson models(The list of phones that can be used with the application is displayed in Step 9 of the process). please follow the instructions carefully: Turn the phone off and disconnect it from the computer.  1. Visit this link:http://www.sonymobile.com/us/tools/pc-companion/Click on Download PC companion2.Run the software After the installation the first screen will show you the PC Companion Startup Guide which gives you a brief explanation on the main modules of PC companion (Support Zone, Xperia Transfer, Contact setup and Media Go) Keep clicking next.3.Now you will see the screen with the different modules.Select Support Zone> Click Start.  The program will download the module. Then click on start on Phone/Tablet Software update. (Here you can choose to update an accessory, go to step 14 for instructions) Note: At this point if you get an error stating that "unable to install update components" or "server is busy" Please proceed to step 13 . If you not see that error then continue with step 4.
    4. The program will show a window saying "could not find phone/Tablet” Do not Connect phone instead select Repair my phone/tablet. This will bring you to a window with a warning that says "data will be lost" (do you want to continue) Select to continue (Data in the phone will be deleted, only data in the SD card will remain. Make sure you have done all proper backups if possible)6. The program will issue a second warning stating that “data saved in the phone /tablet will be overwritten during the update of your phone”. Click on the checkmark box next to the acceptance text and select Next to continue.7. Next the computer will download the necessary files (Prepare stage, this can take several minutes depending on the speed of your connection) and then its done it will show you a list of recommendations for a successful update operation. When you are done reading this section click on the checkmark box and press Continue8. Next you will get a Battery level warning that states that your phone should have at least 80% battery. (If the issue in the phone does not permit the unit from turning on, then charge it connected to the wall charger for at least 2 hours and then comeback to this step) Then click on the checkmark and select Next9. Choose the Phone from the list then click on "next" then you will see a new section telling you how to connect the phone. (don't connect it yet) Again, at this point the phone must be off and disconnected from the PC. 10.. Connect the cable to the PC not to the phone, then while pressing and holding the indicated button (in the steps on screen an specific button will be shown for you to press on the phone) connect the cable to the phone and keep holding the indicated button until the program says "the update of your phone has started..." (in some cases a message of  "Installing drivers" will appear before the message of "the update of your phone has started..."  is shown.) 11. If you failed to follow the steps correctly the phone will turn on. If this happens disconnect the phone from the cable, turn it off and repeat from step 10). 12. If the phone is connected properly, PC Companion will proceed with the update ( It will tell you to let go of the key) then wait for the update to finish and follow instructions on screen to disconnect the unit.  End of process. ----------------------------------------------------------------------If the software fails to install:13. If "unable to install update components" 1. Close Pc companion 2. Install Java from: http://www.java.com 3. start Pc companion again and try to do the software unlock process once more. 14.Select Accessories software update. Click on start and the computer will download the necessary files (Prepare Stage) it will take several minutes. Then follow the instructions from step 8.  Note: Some computers may block the installation of the update service, if this happens use this:http://www.sonymobile.com/us/tools/update-service/ this is the Standalone update software. (Not globally available)If the Phone is unresponsive (Then do this extra step and when done proceed to redo the repair process:Press and hold the power button and the volume up button at the same time for 10 to 15 seconds. This will reset the unit)Note: This procedure does not work for the Xperia Play R800x (Verizon and other Non SIM card variants of the Xperia play that lack MTP support.  It does work for the R800a At&t's model)Bridge For Mac instructions on my post below. Valid for all Android based units and most java Sony Ericsson units. 

    Here are the basic Steps for Bridge for MAC.Download Bridge for MAC from:http://www.sonymobile.com/gb/tools/bridge-for-mac/The phone should not be connected to the MAC.
    The phone should be off.After the Download unzip the file and drag the bridge for MAC icon to the Applications folder. (install then use finder to locate icon)In the Main "No phone connected" window, on the top menu (top application menu) Select "Phone" and scroll down to "Repair phone"
    This will open the Phone Software Restore window with the 3 sections for Start, Prepare and Update.
    Click on continue bellow. Doing so will popup a window warning you about the loss of your personal info. Click on the checkmark signaling that you understand the data loss situation,
    This will take you to the Connection Procedure Screen. Follow the instructions in the screen and click on continue*.
    *One key aspect of the last step to keep holding the indicated button before and after you connect the phone to the MAC until the update starts. IF this is not done correctly then the phone won't connect to the MAC

  • Help for using camera raw in PSE 8/Bridge for Mac for the Canon 7D

    Recently purchasing the Canon 7D, taking a few test photos in Raw, then trying to use Camera Raw in PSE8/Bridge for Mac is a problem.  I cannot figure it out.  Can anyone help this frustrated, novice computer user?

    You need to update the camera raw plug-in for bridge and PSE 8 separately (they use two different copies). In Bridge, just go to Help>Updates which will install, I think, ACR 5.7, which  works with your camera. (You can't update bridge beyond that version).
    For PSE 8, go here, download the latest version and follow the instructions in the readme file.
    http://www.adobe.com/support/downloads/product.jsp?product=40&platform=Macintosh
    Note that the directions may tell you that you can overwrite the old plug-in. That isn't true--you must remove it before putting the new one in there.

  • Setting up Bridge for multiple users on a network

    New Bridge user here
    Can anyone give me some advice on how to set up Bridge for use by multiple users over a network / server?
    We have a large image bank stored on a server and ideally if any one user adds keywords or other metadata to an image I would like the rest of the users to be able to view that data and be able to use it in searches. AS more than one user could add keywords at any time I was wondering is it possible to set up a central keyword file or cache so any updates are available to all users.
    Do I set up a shared cache? What happens if it becomes corrupted and has to be rebuilt, do the keywords disappear as well?
    Are the keywords associated with that particular cache or are they stored in a separate file?
    Thanks,
    Hazel

    Curt
    how do you know if your using the
    Central cache all distributed cache ?
    and are they both stored in the same place ?

  • How to open a zip-file in Bridge for PC?

    How to open a zip-file in Bridge for PC?

    I think it's built in, just double click on it and it should open with Archive Utility. I dunno, maybe Unrar X might work for you>
    JB

  • Unable to perform update with Sony Bridge for Mac

    I have not been able to update my Xperia Z1 (model C6906) through Sony Bridge for Mac.
    While attempting this in SBM version 3.5 the following messages would appear:
    There was an issue with the update engine. Please contact technical support. (reason:failed to start local server)
    then:
    There was an issue with the update engine. Please contact technical support. (reason:failed to parse installer XML(code 11))
    SBM has now updated to version 3.6(3602) and still no luck. The software is able to download the update engine but then remains stuck in the initializing phase, talking to update engine.
    My phone is at build# 14.1.G.2.257. The proposed update seems minor, as the build # doesn't change but it would be great to have this issue resolved in time for kitkat 4.4
    There doesn't appear to be a problem with the phone as the staff at the Sony Store were able to perform my initial out of the box update with PC Companion.
    My Mac is running  OS10.9 and the java version is 1.6.0_65
    Any advice would be much appreciated

    In the mean time it would be worth updating the version of java you are running on your MAC:
    http://www.java.com/en/download/help/mac_java_update.xml
    Don't forget to mark posts that answers the topic as Accepted Solution. 
    If you find any post helpful, press Kudos.
    What are your thoughts about this forum? Let us know by doing this short survey.
     - Official Sony Xperia Support Staff
    If you're new to our forums make sure that you have read our Discussion guidelines.
    If you want to get in touch with the local support team for your country please visit our contact page.

  • Using libraries vs. Bridge for graphics in placeholder frames

    Hi,
    I do not understand the advantanges of using libraries vs. Bridge for my purpose:
    Purpose:
    I am working with templates using graphic placeholder frames. The frames are anchored in table cells and have object styles applied defining e.g. the placement of the graphic within the graphic frame.
    I want to set up central graphic library for all graphics used in all my documents.
    The graphics should then be linked into the documents
    Idea:
    set up various InDesign libraries and then drag the graphics into the placeholder frames. Then, when the graphic needs to be changed, do the changes in the library and have all my documents updated at once.
    Problem:
    Dragging graphics from the library into the placeholder frames does not seem to work. They are simply placed onto the page and NOT in the graphic frame. On the other hand when I simply store the graphics in various subdirectories in my file system and drag the graphics onto the page using Adobe Bridge, they ARE placed in the graphic placeholder frames.
    The library therefore seems a disadvantage, so why should I use a library instead of the Bridge?
    Also, will be upgrading to CS5 soon an want to use the live-linking caption feature. Should I use libraries or the Bridge approach?
    Stumped on this issue

    I like the idea with the snippet, but when dragging a snippet from Bridge there is still the same problem as with the library item: The graphic is NOT placed into the graphic placeholder frame of my template but is a free-flowing new graphic item which has to be placed manually.
    Interestingly, a JPG-file simply saved in the filesystem and dragged from Bridge and dropped over the placeholder frame WILL place the JPG into the frame!
    Why won't snippets do this??

  • Does adobe photo downloader come preinstalled with Bridge for cs6

    If bridge for photoshop cs6 does not have "adobe photodownloader pre installed . How do I get this software.

    It comes with every install of Bridge. Nothing else required. You jsut need to enable it from within the program's options, if you want to use it.
    Mylenium

  • Problems with Bridge for Mac 3.7

    I've been using Bridge for Mac for a while without any problems, but since it downloaded the 3.7 update it won't recognize my phone. When I connect, it thinks for a few seconds, then says it cannot connect. I've tried deleting and redownloading the app, and deleting any relevant system files I can find. If I connect it in Windows with the same cable and through the same USB port, PC Companion recognizes it no problem. Any idea what's going on here?

    Hi mcilwr01,
    I'm sorry Bridge isn't working for you, and I understand you're upset. 
    Could you please send me error logs that I can forward to the development crew? Otherwise it's near impossible to tell what's causing your problems.
    Here’s how to get error logs from Sony Bridge for Mac:
    1. In BfM, hold the "alt" key down while selecting the "Phone" menu. Select "Clear logs" to remove all old logs and get a clean start
    2. Reproduce the problem you're having, whether it's connecting the phone, importing photos, doing backup...
    3. In BfM, hold the "alt" key down while selecting the "Phone" menu. Select "Export logs"
    4. On the computers desktop there should now be a file named "SonyBridgeForMacLogs_[date].zip
    5. PM that file to me or post the contents here 
    We are working on solving the problems of 3.7 as fast as possible, I apologize for not having a solution for you right now.
    Best Regards,
    David

Maybe you are looking for

  • Monitoring Adapter Engine J2SE

    Hi, I have setupt he SLD Accessor on the J2SE Adapter Engine. If one check in the log the connecting to the SLD is successful. Also the Adapter Engine is registered in the SLD as type XI Adapter Engine in Technical Systems > Process Integration. I ca

  • Green Screen can't see video

     Hi guy's ,  I've bought a new laptop and now all of a sudden I can't watch a video as it's a green screen. is there any obvious reason for this ? Thanks Diane This question was solved. View Solution.

  • Error in Posting Periodic Postings for Assets

    Hi I have an error in processing periodic posting of Assets. We have three depreciation areas. Depreciation Area 01 calculates the depreciation as per local reporting requirements and updates the GL. We have depreciation area 15 which calculates the

  • Db2 - bea jdbc type 4 driver error - cursor not in a prepared state

    Hi I am getting this error from BEA DB2 Driver in weblogic console. java.sql.SQLException: [BEA][DB2 JDBC Driver][DB2]CURSOR C02 NOT IN A PREPARED STATE This problem occurs frequently almost everyday. When this error happens we clear the statement ca

  • Windows 2008 r2 64 bit with 64 bit CF 8 - ODBC drivers missing excel

    We installed a 64 bit CF8 enterprise server on our 2008 r2 64 bit system and we can't seem to figure out the ODBC problems. Most of the solutions we find online seem to apply to 32 bit versions of CF (on 64 bit 2008) - not x64 on x64 2008. We've alre