Question about configuring Global IPv6 address on interface

It seems when configuring a global IPv6 address on a layer 3 interface, we cannot specify the whole 128 bit address. We can only specify the prefix and leave the last 64 bits to be generated by the router:
http://www.cisco.com/en/US/docs/ios-xml/ios/ipv6/configuration/12-2sx/ip6-addrg-bsc-con.html#GUID-70188E8F-16D2-4DD1-8DE2-70073FF37CC8
Then how can I specify the router address to the client using DHCPv6? Do I have to keep the router RAs while using DHCPv6 together?
Thanks.
zhenning

Hi Leo,
Where is it stated in this doc that you can't configure a /128 ?
Router(config-if)#ipv add 2001::1/128
Router(config-if)#do sh ipv int lo0
Loopback0 is up, line protocol is up
  IPv6 is enabled, link-local address is FE80::9CD7:2EFF:FEF0:99FA
  Global unicast address(es):
    2001::1, subnet is 2001::1/128
  Joined group address(es):
    FF02::1
    FF02::2
    FF02::1:FF00:1
    FF02::1:FFF0:99FA
  MTU is 1514 bytes
  ICMP error messages limited to one every 100 milliseconds
  ICMP redirects are enabled
  ND DAD is not supported
  ND reachable time is 30000 milliseconds
The IOS accepts it on any interface but it will only work for Loopbacks.
I configured a /126 between 2 serials and it worked without any problem but for prefix-advertisement through RA  to work then you must configure a /64.
Regards.
Alain

Similar Messages

  • Some questions about configuration in MAX.

    Hello,everyone!
    I have some questions about configuration in MAX(I am a jackaroo for motion control development),I hope I can get your help.
    I use PCI-7344+UMI-7764+Servo amplifier+Servo motor,my MAX version is 4.2 and I use NI-Motion7.5
    My question as following:
    1,In Axis Configuration,for motor type,why I must select stepper but not servo?my motor is servo motor!If I select Servo,my motor can't run,I don't know why.
     If I select stepper,though motor can work but I can't test encoder in MAX.
    2,In Stepper settings,for stepper loop mode,why I must select open-loop but not close-loop?If I select close-loop,the servo motor doesn't work too.
    3,If I want my two servo motors run at different velocity,How shoud I do?It seems I just can set the same velocity in MAX for my two servo motors.
     My English is poor,Pls pardon me!I come from China.
    Thank you for your help!
    EnquanLi
    Striving is without limit!

    Hi,Jochen,
    Thank you for your kindly help!
    The manufacturer of the drive and motor that I am using now is Japan SANYO DENKI,drive type is RS1A01AA,motor type is R2AA06020FXP00.
    And I use position control mode,thehe encoder's counts per revolution is 131072.I set the electronic gear ratio to 1:1 for drive.
    Now,I can use Close-Loop to control the motor but still has some problems.When I configure it to run in closed loop mode, the motors behave strangely and never move to the target position.When I configure it to run in closed loop mode, the motors behave strangely and never move to the target position.The detail situation is as following
    1,Motor can't run.
    2, Or motor moves to a position, then moves in the same direction agian and eventually stops.
    Except for the  two points mentioned above,"Following Error" is  occured frequently,I don't know why.
    I am still not clear why I must set the motor type be stepper in MAX .
    And I have another question:what the relationship between the steps and the counts?They have the proportion relations?I notice that there are a section said like this in help document: For proper closed-loop and p-command operation, steps per revolution/counts per revolution must be in the range of 1/32,767 < steps/counts < 32,767. An incorrect counts to steps ratio can result in failure to reach the target position and erroneous closed-loop stepper operation.
    I am verry sorry I have too many questions!
    I am very appreciate for your kingly help!Thanks again!
    EnquanLi
    China
    Striving is without limit!

  • Register global IPv6 Address on NRPT defined DNS-Server

    Hello
    I have implemented IPv6 on my home network and I am using Windows Firewall with IPSec to secure connections from foreign networks to my home network.
    I configured a NRPT with generic rules for my domain so my client is using the home DNS-Server to resolve names of computers on my home network. This is working quite good so far but I it seems like the foreign client does not register his own
    global IPv6 on the home DNS-Server.
    When i run ipconfig /registerdns the list of servers to which the update has been sent to is empty (<?>) while the DNS-Server list does not mention the DNS-Server configured using NRPT. So my very simple question is: How can I configure my Client to
    register DNS based on the NRPT or a static list of DNS-Servers?

    Hi,
    Does the FQDN of the foreign client  match the NRPT rule?
    Please make sure that the FQDN of the foreign client matches the NRPT rule. Then when the client try to send a update packet, it will be redirect to the internal DNS server.
    Best Regards.
    Steven Lee Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • Question about configuring Etherchannel on Catlyst 3750

    Hi, I have a stack witch catalyst 3750, I mean I have 3 switches ( 1 master, 2 slaves)
    My question
    Can I configure an etherchannel having 2 interfaces on each switch?
    How can I do this?
    Thanks
    Regards

    If you have a stack it should present itself as a single switch just put channel-group 1 desirable nonsilent if you are going to another cisco on each of the interfaces you want in the channel . this is for a layer 2 etherchannel . For a layer 3 etherchannel is somewhat more involved and too long to write here , just go to the cisco.com site and search on configuring etherchannels,3750 .

  • I have a question about Configuration of Post with Clearing

    I have a question about confiruation of the post with clearing which is t-doce 'FB05'.
    When I make post with clearing on 'FB05', I can change the additional selections.
    Where can I control the confiruation of the additional selections in t-code 'FB05'
    Please, tell me the menu path.

    Hi,
    In SPRO, go to
    Financial Accounting (New) > Accounts Receivable and Accounts Payable > Business Transactions > Incoming Payments > Manual Incoming Payments > Make Settings for Processing Open Items > Choose Selection Fields
    Hope this helps.
    Thanks

  • Questions about the Global Shipping Program

    Unfortunately, no. "Import fees" are only charged if the seller is using the Global Shipping Program on eBay.com.If you read the fine print in the Buyer's User Agreement for GSP, there is this under paragraph 3: i. Exclusions. You alone are responsible for any customs duties, taxes, surcharges, fines, penalties, or other charges which may be imposed on you by customs or tax officials after a GSP Item has successfully cleared customs and been delivered to (or made available for pickup at) the delivery address specified by you. http://pages.ebay.com/shipping/globalshipping/buyer-tnc.html My interpretation of that, is that if there are any additional charges, the buyer is responsible for paying them, even though you were not informed about them in advance. Personally, I would not use the GSP, for this and other reasons. Your only alternative is not to purchase items that show Import Fees on the shipping and handling tab. Unfortunately, this is not a very good solution. 

    around_again_records wrote:
    When you pay for the item through PayPal, you are authorizing 2 payment transactions. The first payment goes to the seller and consists of the item cost and the domestic shipping costs. The second payment goes to the global shipping provider and consists of the international shipping costs and any import charges.The above quote is from the Global Shipping Help file. My question is: If I were to make a purchase from someone using the GSP (and I won't but...) and I go to the shipping page to calculate my cost. Where do I put that the item is going to be shipped to? IF the first payment goes to the seller and consists of the item cost and the DOMESTIC shipping cost - then to find out the Domestic shipping cost do I enter the location of the Pitney Bowes Shipping depot????
    How do I know what Pitney Bowes (or the Global Shipping Provider) is going to charge me for shipping? I absolutely need to know that before I make any purchases. From what I understand, I will find this all out during checkout. That's a little bit late for me. Same thing with duties and taxes. I need to know what they are going to charge BEFORE i get to the checkout. When parcels go through normal channels USPS/CP I know how much tax I might have to pay and I know how much the duty charge will be. I would never purchase anything without knowing these costs up front. Hi, Round-again.  Hope you and Kalvin don't mind my leaping in here.  I went through a test listing from a seller using the GSP some time ago, so I may have a bit of insight for you. GSP listings have shipping charges and estimated import charges right on them.  Usually, those "estimated" charges are pretty accurate, but I think they have to be considered "estimated" for auction listings where the taxes due on the item are going to go up as the bid price rises. In the case of my test listing, the shipping charge and import charges were just as were mentioned on the listing page and it was a simple matter of going through checkout, agreeing to the terms and conditions of the Global Shipping Program, and almost making my payment. The wrinkle is that since everything but the kitchen sink is thrown into the import charges and they're not itemized, you can't be 100% sure how much is going to taxes, how much to duty (which often isn't applicable anyway), and how much to the Global Shipping Program as an administrative fee.  However, you can calculate the taxes yourself using the tax rate(s) applicable to your province if you need to get an idea of how much is going to whom. This likely isn't a perfect solution for you if you're trying to claim back any taxes (and duties, if applicable) paid on the item, but it's probably the best we can do right now with how the GSP is set up.

  • Question about configuration of NAT on ASA

    Hi all,
    I have ASA config with DHCP and its providing IP to users.
    ASA is connected to 3550 switch it has direct connection or say default static route
    From 3550 switch  connection goes to Router and it does the NAT   and has connection to outside world.
    My question is do i need to configure the NAT inside  and global (outside ) on the ASA  or not?
    As per my understanding NAT is done by router which has connection to ISP.
    Thanks
    Mahesh

    Hi Jennifer,
    Thanks for replied.
    I tested like this  config the NAT on ASA 
    then as per your reply run the command no nat-control as ASA ver is 8.4
    But nat config is still there in ASA.
    I did sh xlate it shows
    ciscoasa# sh xlate
    27 in use, 371 most used
    PAT Global 192.168.11.2(33396) Local 192.168.1.5(57177)
    PAT Global 192.168.11.2(61657) Local 192.168.1.5(57176)
    PAT Global 192.168.11.2(52259) Local 192.168.1.5(57175)
    PAT Global 192.168.11.2(30453) Local 192.168.1.5(57174)
    I did clear xlate still there is output from the sh xlate
    My question is how we test that ASA is nating or not ?
    Which commands can tell us that ASA is doing NAT ?
    Thanks
    MAhesh

  • Ucs question about major code F0283 and dce interfac and chassis number?

    dear,
    Introductions:
    one 6120 connect  chassis 1 one 2104-1 and   chassis 2 one 2104-1
    chassis 1 have sever 3/4/5/6/7/8  (all sever is B200 M3,two 2104)
    chassis 2 have sever 1/2/3/4/5/7 (sever 1/2/3/4 is B200 M3,two 2104)
    question
    1.major code F0283
    all server have  major code F0283 ,but all sever  still can use.what this? How I did it?
    affected object:sys/chassis-1/blade-6/fabric-A/path-1/vc-722
    description: ether vif 1/6 a-722 down,reason: unknown
    chassis 1 have sever 3/4/5/6/7/8
    chassis 2 have sever 1/2/3/4/5/7
    i shutdown all ,and start the problem is also.
    affected 
    i shutdown all ,and start the problem is also.
    2.on chassis 1 sever-1 adapter 1 dce interface (dce interfac 1 and dce interface 5)
    ony one use? 
    3.
    chassis 1 have sever 3/4/5/6/7/8
    chassis 2 have sever 1/2/3/4/5/7
    but i reboot ,
    chassis 2 have sever 3/4/5/6/7/8
    chassis 1 have sever 1/2/3/4/5/7
    so the profile is disorder
    i shtdown all,and start chassis 1 ok ,later chassis 2
    the problem is ok..what this ?

    Hi Hailing,
    The transport VIF for server is down.The Cisco UCS Manager raises this fault when any of the following scenario occur:
    •Endpoint(switch/fabric  interconnect) reports the connectivity state on virtual interface as  one of: a.down, b.errored, c.unavailable.
    Verify  that the blade discovery was completed successfully. Check the states  on all of the communicating ports in an end to end manner.
    If connectivity seems correct, recommision the server.
    Also, please make sure you are using the correct drivers of the OS installed in the server as Padma recommended you.
    I hope this helps.
    David

  • Question about configurations in Old Server

    Dear All,,
    I have a Question !
    How will you find what are the configuration are in a server.. for example..
    Is the DB configured RAC or DATA guard ?
    Is RMAN configured or not ?
    because at any time we have to face this request for Client who they don't have details regarding their Server,, (in Old Support Projects).
    if i have a plan for a upgradation of database what are the documents i have to prepare and what are the steps i have to take at initial stage !
    Regards
    HAMEED

    Hameed,
    This should be documented and those documents should be provided by the clients.
    You could do some investigation but again this will not be correct or complete without the documentation. For example, for RAC you could query the dynamic views (gv$instance, v$instance on each node) but this assume you already know what servers are configured. Or, you could refer to the RAC/DataGuard/RMAN configuration MOS docs for Oracle E-Business Suite and go through the steps to verify if those configurations are presented or not.
    Thanks,
    Hussein

  • Question about configuring REST web service in EBS instance

    I am from EBS SCM team. From one wiki page, it says OA Framework provides REST framework to expose OAF BC4J objects as web services. Can you provide more details about how to configure REST web service for one EBS instance? Any related information is also helpful.
    Edited by: 936859 on Sep 7, 2012 5:45 PM

    IIRC you must activate PAPI-WS for the engine. In Studio you do it by right-clicking on the project, then "engine preferences". In enterprise/standalone you must activate PAPI-WS in the Admin Center.

  • The question about configuration Organization Unit on spro

    Dear all.
    I want to configuration Organization Unit on spro so I have created O.Units, Jobs and positions on Personnel Administration->Organizational Assignment->Organizational Plan  but I can't see these values about O.Unit, job and position on  SAP Access Easy .
    How to see these values on  SAP Access Easy ?
    Can I input these values about O.Units, Jobs and positions on spro ?
    Thanks so much.
    Huyen Nguyen

    instead of that
    Define the Number ranges
    in OOCR
    for all the objects
    Make a Template for Objects and Object Id
    and upload the same thru PP01
    than all the enties will sit in the SPRO
    >note it is not mandatory to create thru SRPO wht in case if u have 4000 to 5000  Employees
    So the best way is upload the Data thru LSMW thru Proper objects and Relatioships

  • Questions about configuring sshd

    I checked the server admin manual and didn't find much detail on this topic. I took a look at the man page for sshd, but didn't really understand everything I read. Hoping someone here can help me understand how to configure sshd in OSX. I'm pretty new to OSX, but I have some experience working with Linux hosts. Working with sshd seems a little different on OSX.
    I need to adjust the system wide setting to timeout inactive SSH sessions. Currently a stale session will hang open for ever. I need to set the timeout to 15 minutes. Where/How is this done? Is this done in /etc/ssh_config by setting a value for "ConnectTimeout?" Is this seconds or minutes?
    How do you restart sshd after making changes to the config?
    What is the difference between /etc/ssh_config and /etc/sshd_config?

    First off, there are two config files of interest here:
    /etc/ssh_config - configuration file for the ssh client
    /etc/sshd_config - configuration file for the ssh server
    If you make a change to sshd_config then the change will apply to all connections made to this server. Making changes to ssh_config affect outgoing connections initiated by this machine.
    So the first question is which file to edit.
    If you want to control this at the server side (so idle connections are terminated by the server) then edit /etc/sshd_config.
    All the options are covered in the sshd_config man page:
    # man sshd_config
    Specifically, I think you're looking for a combination of ClientAliveInterval and ClientAliveCountMax.
    ClientAliveInterval sets how frequently SSHD checks the client connection. If ClientAliveCountMax tests are performed without any response the connection is closed.
    So, for your 15 minute disconnect you could set the ClientAliveInterval to 300 (5 minutes = 300 seconds), with a ClientAliveCountMax set to 3 (you don't want to set it to 15 minutes/1 Max since any temporary network delay could cause the connection to drop).
    To control this from the client side, the corresponding parameters to add to /etc/ssh_config are ServerAliveInterval and ServerAliveCountMax.
    How do you restart sshd after making changes to the config?
    Changes are dynamic, and applied to each new connection (i.e. the next time you log in it will use the current sshconfig/sshdconfig settings).

  • Question about syncing iPhone and Address book

    I recently deleted some unwanted and outdated contact information from my address book on my computer. It synced correctly to my iPhone, but did not prompt me about the lost contact information. I also added one or two new contacts to my iPhone but when synced, it did not transfer these to the address book. Does one device take precedence over the other? Is there a way to set the preferences to prompt me before it deletes contacts from my iPhone? Thanks!

    Ah, never mind. I'll give up on this thread and bug my IT guy instead.

  • Question about configuration (ATI 5770) w/ 3 monitors

    Ok I already know how to get three monitors running on the ATI 5770.  I have one native mini DisplayPort, one mini DisplyPort to VGA and one native  DVI or DVI to HDMI.  What I need to know (before I buy another native mini DisplayPort monitor) is if the 5770 can run two native mini displayPort monitors and a native DVI?  Has anyone done this?

    i am currently running 3 displays on my macpro 1,1 with a 5770 card. here is my setup
    mini display port to dvi (dual link active from monoprice) to an Acer 24" monitor
    mini display port to dvi (sme as about) to and dvi to hdmi adapter to 65" 1080i television
    dvi port to Acer 24" monitor.
    i have to set it up this way because if i set both monitors to mini display port adapters and the tv to the dvi to hdmi adapter one of the monitors will not come on. setting it this way all three monitors are working. the only problem that i have is that my tv monitor flickers like the computer is refinding it all the time. i haven't really had a chance to look into it too much, but i can tell you that without the active link adapters only two of the three connections will work at one time.
    hope this helps

  • Questions about configuring passwords ...

    RAS-ROUTER:(config)#enable secret ?
    0
    5
    LINE
    whats the difference between using the number '0' and then typing the password from just typing the acctual password?
    Thanks

    hi
    AFAIK u can enter the unecrypted string as the password after keying in 0 which we does normally when configuring the password.
    which it does enrypt using md5 algorithm and displays in the running config.
    Router(config)# enable secret cisco
    Router# show running-config
    version 12.1
    no service single-slot-reload-enable
    service timestamps debug uptime
    service timestamps log uptime
    no service password-encryption
    hostname CE
    logging rate-limit console 10 except errors
    no logging console
    enable secret 0 $1$53Ew$Dp8.E4JGpg7rKxQa49BF9/
    when u use keyword 5 in conjuntion with the command then u need to enter the encrypted keystring followed by 5.
    regds