Question on delta from ODS

Hi,
I've a question.
Lets say I'm doing a full load to a ODS (say ODS1). From this ODS1, can I do delta loads to say another ODS2 or a Cube?
Regards,
Vikrant

Hi Vikrant......
Whenever we load data to an ODS..........data will first com in the Activation Queue............after activation of the ODS........data will moved in the Active table and the Change log table.......Now suppose a particular value is changed......that that change will overwrite the value in the Active table............and the changes will get recorded in the Change Log table.........
Check this Example.........
http://help.sap.com/saphelp_nw04/helpdata/en/f9/45503c242b4a67e10000000a114084/frameset.htm
So ......first when u did Full upload............all the data loaded in both the Active table and the Change log table.......after that u hav'nt done any changes.........right?......So in ur case no of records in ACtive table and the Change log table is same..........U can cross check it.........Go to the Manage screen......Contents tab >> there Check the Active table : Active data..............and Change Log table : Change log.............there click on No of Records.........
Regards,
Debjani...

Similar Messages

  • Doubt on Deltas from ODS to CUBE

    Hello Experts.
    I have few Questions on Deltas.  from ODS to CUBE
    I have 3 Cubes ( X, Y, Z )  which gets Deltas from ODS ( A ) .  i have extended the cube X so i have deleted data and Reloaded it.  I have to do Deltas from ODS to Cubes from now on.
    in the ODS manage ( there is Tick all connected data Targets to this Request is been Delted now ). 
    if i reinitalize the delta with out Data Transfer.  will only the data which come now on to ODS(  A ) will be going to cubes( X,Y,Z ) are all the data in ODS will go to Cubes.
    Please Advice me.
    Thanks
    Sharp

    Hi,
    When you are loading the delta from the ODS, the data is taken from the changelog. These records are the + and - records generated as a result of the new data loaded and activated in the ODS. So, if there were any changes made to the existing records these will flow to the cubes as well.
    If you do the init without data transfer, you need to couple that with the full load to create the initial status of data in the cubes.
    Hope this helps...

  • Restore failed delta from ODS to cube

    Hi All,
    I have started a delta load from ODS to cube but it has failed abruptly, for some reason, with out extracting even a single record.
    I want to restart/re-schedule the load but I am confused how to do that(just a delta or repair/repeat delta).
    Can someone please suggest how to proceed.
    Rgds,
    RPK.

    Hi Ravi,
    I had to stop the request because of some other issues and now I have to start it again. There is no particular error.
    Hi PB,
    Thanks a lot for the reply. Are you sure that I have to delete this failed request first? Will it prompt for a repeat delta when I try to schedule it again?
    Sorry for asking these questions but just want to make sure about it.
    Rgds,
    RPK.

  • Error 8 while do init delta from ODS to ICube

    I got error while was trying to load Init data by InfoPackage from ODS to Cube:
    Error                                                   8 when starting the extraction program
    Message no. R3019
    Diagnosis
    Error                                                   8 occurred when starting the data extraction program.
    System Response
    The data extraction is terminated.
    Procedure
    Check for relevant OSS Notes, or create a problem message of your own.
    There is no any OSS notes regarding this error, I checked forums - non of the answers didn't work for me.
    Additional info:
    I got this error after canceling Init Load to the same Cube (by changing load Status to red). After that I deleted all data from Cube, also did reset Delta Init in InfoPackage. I suspect this job cancellation caused this problem. How can I repair it?

    Hi,
    Check this Note 147104 to edit table ROIDCPRMS.
    Regards
    Lavanya

  • Short Dump while loading Delta from ODS to ODS

    Hi Experts,
    I have run into a short dump error while loading delta from one ODS to another via a process chain.
    Following is the error message:
    Error analysis                                                                               
    Short text of error message:                                                                 
        Request 0000259294 is not completely activated. Please activate it again                     
    Technical information about the message:                                                     
         Diagnosis                                                                               
    Activation of request 0000259294 has terminated, or is not yet                          
             complete.                                                                               
    System response                                                                               
    Procedure                                                                               
    If the process has terminated, all of the requests that the system                      
             was unabe to activate in the most recent activation process have to                     
             be reactivated before the new requests can be activated.                                
             If you are not able to carry out this activation step, delete the                       
             relevant requests from the administration of the ODS object (on the                     
             Requests tabstrip).                                                                     
         Procedure for System Administration                                                         
        Message classe...... "RSM1"                                                                  
        Number.............. 180                                                                     
        Variable 1.......... 0000259294                                                              
        Variable 2.......... " "                                                                     
        Variable 3.......... " "                                                                     
        Variable 4.......... " "                                                                     
        Variable 3.......... " "                                                                     
        Variable 4.......... " "                                                                     
    Can someone help me resolve this?
    Thank you

    Check the status of request SID 259294  in ODS, whether the Activation got completed or not. If not wait till the activation completes.
    If there is any problem in the activation process, correct that complete the activation process and load the ne request that you want to load..
    Regards
    VJ

  • Question : Init delta in ODS

    Hello,
    I have a doubt regarding init delta in ODS...
    I have done following steps :
    1)delete ODS and cube data (right click on ODS -> delete data)
    2) did full load in ODS and to cube till date ....
    3) delete Initialisation from infopackage schedular by making forced red...
    Now i am getting different suggestions from my seniors that....
    <b>a></b>   I should do repair full request in ODS ...before starting init delta....
    <b>b></b>  No need to do repair full request -> just start init without data transfer  -> it will give error in activation of data  ->  manually activate the ODS data -> update it to cube...
    Can anybody please tell me what i should do....?
    Thanks.

    hi preeti,
      Please follow the steps...
      1) Delete the data in ODS and CUBE completely.
      2) Do Init without data transfer to ODS first from source system.
      3) Then do the full load into the ODS from source system....
      4) Follow the same steps from ODS to Cube as well.
          Do the init without data transfer to CUBE from ODS and then do the full load
           from ODS to CUBE...
      Believe me this will work fantastic.....
      Hope it helps.....

  • Init delta from ods to two cube seperately

    Hello,
    Can we run init seperately two times for the two different cubes from a ODS which is used as an staging ODS?
    ODS1-> for cube1 initialise delta with data transfer
    ODS1-> for Cube2 initialise delta without data transfer
    is it possible to do like this?
    Thanks in advance!
    Points will be assigned!
    Regards
    Ram

    Hi Rakesh,
    I think it should not have been possible to do initializing with data transfer and without data transfer for the same data target.
    I mean init with data transfer to cube 1 and init without data transfer to cube 2 from ODS.
    Not to the same Cube. Will it be possible like this?
    Regagrds
    Ram
    Points will be assigned

  • Repeat delta from ODS to Cube.

    Hello All,
    The data is coming from ODS to InfoCube...
    Load for 24.05, 25.05 and 26.05 is successfully uploaded in ODS (full Upload) from R/3 system.
    But the load for date 25.05 failed in InfoCube due to invalid chs. in one of the field.
    The infocube is Z_CAD (Delta upload) and is fetching data from ODS Z_AD.
    How do I make sure that I delete the request in InfoCube. and repeat the load from ODS for 25.05 and 26.05.
    Kindly explain step wise.
    I also have to make sure that the data mart status is set for further loads.
    Kindly reply.
    Regards,
    Nikekab

    Hi,
    Since your data is available in ODS.
    Delete the request for that day from Cube by making the request red in both Manage and Monitor screen.
    Then rectify the invalid characters issue either by maintaining it in Tcode RSKC or by writing routine for it.
    Then you can do a reconstruction as the reconstruction tab will available in the  manage screen.
    Kindly let me know in case further details are required.
    Thanks,
    Amit Kr.

  • Reg Delta from ODS to Cube

    Hello , experts.
    I am doing delta Load  from ODS1 to Cube1, delta got failed.  and in the ODS we have data.  i want to reload it or i want to do repeat delta .
    Problem is in the ODS its Marked that request as updated to data targets.  in this case how should i proceed to repeat delta.  i need steps to do this.
    Thanks
    Sharp

    Hi Sharp,
    try to remove the mark (via ODS - manage - remove the 'mark' and update the data from ODS to the target cube again (ODS - right mouse click - check delta update option).
    Hope it helps.
    Li

  • Mixed Full and Delta from ODS to Cube

    Hi,
    we're facing the following problem:
    We're loading data from an ODS to a Cube via Delta, every night. Due to reporting needs it's
    nessesary we have to write some Infoobject-attributes to the cube. 
    This attributes will change sometimes. To display the current truth, we have to delete the old
    assignments from the cube and update them with the new attribute values.
    My idea was the following:
    1. Identify the lines in the cube with the old attributes
    2. Delete them via "selective deleting"
    3. Load the lines with the new attributes from the ODS to the Cube
    4. Proceed with delta upload from the ODS.
    Is it a possible way or any better ideas.
    Kind regards
    Lars

    Hi,
    thanx for your reply. Of course we update the attributes:
    For example:
    Today Infoobjekt IO (Value IO-Value) has Attribute A with the value B.
    Row in Cube:   IO-Value, B, Keyfigure.
    Tomorrow: Today Infoobjekt IO (Value IO-Value) has Attribute A with the value C.
    So I have to correct the value of the attribute in the Cube.
    Navigation Attributes can't be used.
    Lars

  • Delta from ODS to cube

    Hello Gurus:
    Is it possible to give slection criteria during 'Delta Initialization process' ?
    I just saw that -- for full load, I see selection criteria in Infopackage. But, for Delta Init selection criteria is protected. Can you suggest why?
    I will be happy to assign points.
    Thanks

    Dear KK,
    From what i know ..
    Due to it's delta ..
    Delta is the methods for fetching the data that has a new/modified type. So off course it will be protected ..
    It will be different w/ full-upload, where you can define the selection as you wish..
    Hopefully it can help you a lot.
    Regards,
    Niel
    thanks for the points you choose to assign.

  • Automatic loading from ODS to Cube in 3.5

    Hi All
    I was under the impression that in version 3.5 in order to load delta from ODS to Cube you had to run the 8 series Ipak.
    However I have recently noticed that this ipak is running automatically after a delta load into the ODS even when the load is not via a process chain.
    Can somebody where and how this setting is maintained.
    Regards
    A

    Hi,
    Go to ODS display mode and check if "Update Data Automatically" is ticked in Settings.
    Regards,
    Kams

  • Question on Deltas after Init and Full load

    Hi
    We have an ODS X pushing data to two cubes A & B. ODS X data is initialized to Cube A long back and deltas are loading every day. Now We have recently created Cube B and made a fulll load from ODS X and loading the Deltas from ODS X with same info package we are using to load the deltas in to cube A. Do we get any data inconsistencies if we load like this ? Do I need to make a new init for Cube B to get proper deltas ? I'm hoping that Deltas will automatically take care of reversal in Cube B too...Please advice.
    Thanks
    Sam

    This looks fine, since u have already done full load from X to B, and currently loading delta to both A n B , it is fine, no need for new init.
    Regards,
    Rathy

  • Delta Upload request from ODS is not including the Data target of planning

    Hi,
    I have a process chain in which there is a delta upload from ODS to 3 different data target.  One of the data target is the planning cube. last 2days back i have changed the process chain schedule after was the Delta request is not hapenning for Planning cube.  The process chain contains the changing the planning to load mode and load to planning mode.  Every thing is working fine but the Delta is not happening for the Planning cube.  Delta request are going correctly to the Other 2 data targets.  Now it was like Delta has excluded the Planning cube.  Another this there is nto planning package is appearing in the Infousources.  and when I am trying to upload manually from ODS to Data targets it say that No delta is there.  Please help me in this.  This is a production problem.   I have checked all the data monitors every thing is from but no delta is hapenning for the planning cube.   
    Thanks
    Naveen.

    Resolved

  • Deactivate delta update before deleting the request from ODS

    Hi all,
    Happy New Year wishes to all.
    I have a scenario, where I am feeding the data to ODS from flat file and from ODS to Cube. Here ODS is a Data mart. Flat file to ODS full update and ODS to Cube First Initialization and Delta.
          I deleted the latest request from ODS, at the I got the message dialog box and it is saying that
    “Request 98888 already retrieved by data target BWVCLNT”
    “Delta update in data target BWVCLNT must be deactivate before deleting the request
    “Do you want to deactivate the delta update in data target BWVCLNT?
    So I pressed Execute changes, then after I loaded the data in to ODS and when I am trying to load the data into Cube, once I pressed execute button it is displaying the message dialog box like
    “Delta request is incorrect REQXXXXXXX in the monitor”
    “A repeat needs to be requested”
    “Data target still include delta request REQXXXXX”
    “If the repeat is now loaded, then after the load”
    “There could be duplicate data in the data targets”
    “Request the repeat?”
    After execute changes it is showing only “zero” Records only.
    What is that mean and why zero records it is displaying instead of delta records.
    Anybody faces this type of problem please let me know. This is somewhat urgent to me
    Thanks and Regards
    Satish Chowdary

    <i>Hi Satish,
    First Switch off the ODS ( automatic Update of Datatarget ) , though not really necessary. delete the Req from the Infocube, then delete from the ODS . Now delete the Init Req from the Infopackage for datamart infopackage.then Do an Init without datatransfer into Infocube. Later load data into ODS and then go for delta update to Infocube.
    I hope this helps.
    Thanks,
    Krish
    Dont Forget to assign Points.</i>
    Dude, you just repeated my answer I gave a few hours ago. Are you hungry for points?

Maybe you are looking for

  • What happened to my pics in the camera roll (4s)???

    Pictures taken today are showing up normal and clear as a group under camera roll.  But they are fuzzy and unclear when each picture is clicked on individually.  Some pictures are even "hidden" under older pictures and are only "uncovered" when I cli

  • How to Batch change dates?

    I have a cannon rebel t1i and am using the latest version of iPhoto ( as of 7/10/10 ). I went to China recently and use two cameras. I changed the date and time settings on the other camera, but not on this one. When importing, in my China event, the

  • How to Track 57 A4 no.

    Hello The Jobwork Process is Handled by Production and Inventory Transfer Documemt. 1. Purchase Raw Material From Supplier and receive it to your Premises 2 .inventory Transfer it to Jobwork warehouse like send for Jobwork and Print the Form 57F4Chal

  • Portal integration with Busniess Objects

    Hi, I have a customer who is looking for Oracle portal solution. They have an sso in place using Business Objects and they also have Active Directory for storing user information. They just want to login to Portal through SSO and access their Busines

  • Using APIs with Edge (JQuery and JSON)

    Hi I am very new to APIs but I have a pretty basic understanding and I want to figure out how I could use them in Edge. I following the following tutorial and have tried to modify it for my liking: http://www.gotoandlearn.com/play.php?id=168 Essentia