Questions about configuring passwords ...

RAS-ROUTER:(config)#enable secret ?
0
5
LINE
whats the difference between using the number '0' and then typing the password from just typing the acctual password?
Thanks

hi
AFAIK u can enter the unecrypted string as the password after keying in 0 which we does normally when configuring the password.
which it does enrypt using md5 algorithm and displays in the running config.
Router(config)# enable secret cisco
Router# show running-config
version 12.1
no service single-slot-reload-enable
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
hostname CE
logging rate-limit console 10 except errors
no logging console
enable secret 0 $1$53Ew$Dp8.E4JGpg7rKxQa49BF9/
when u use keyword 5 in conjuntion with the command then u need to enter the encrypted keystring followed by 5.
regds

Similar Messages

  • Some questions about configuration in MAX.

    Hello,everyone!
    I have some questions about configuration in MAX(I am a jackaroo for motion control development),I hope I can get your help.
    I use PCI-7344+UMI-7764+Servo amplifier+Servo motor,my MAX version is 4.2 and I use NI-Motion7.5
    My question as following:
    1,In Axis Configuration,for motor type,why I must select stepper but not servo?my motor is servo motor!If I select Servo,my motor can't run,I don't know why.
     If I select stepper,though motor can work but I can't test encoder in MAX.
    2,In Stepper settings,for stepper loop mode,why I must select open-loop but not close-loop?If I select close-loop,the servo motor doesn't work too.
    3,If I want my two servo motors run at different velocity,How shoud I do?It seems I just can set the same velocity in MAX for my two servo motors.
     My English is poor,Pls pardon me!I come from China.
    Thank you for your help!
    EnquanLi
    Striving is without limit!

    Hi,Jochen,
    Thank you for your kindly help!
    The manufacturer of the drive and motor that I am using now is Japan SANYO DENKI,drive type is RS1A01AA,motor type is R2AA06020FXP00.
    And I use position control mode,thehe encoder's counts per revolution is 131072.I set the electronic gear ratio to 1:1 for drive.
    Now,I can use Close-Loop to control the motor but still has some problems.When I configure it to run in closed loop mode, the motors behave strangely and never move to the target position.When I configure it to run in closed loop mode, the motors behave strangely and never move to the target position.The detail situation is as following
    1,Motor can't run.
    2, Or motor moves to a position, then moves in the same direction agian and eventually stops.
    Except for the  two points mentioned above,"Following Error" is  occured frequently,I don't know why.
    I am still not clear why I must set the motor type be stepper in MAX .
    And I have another question:what the relationship between the steps and the counts?They have the proportion relations?I notice that there are a section said like this in help document: For proper closed-loop and p-command operation, steps per revolution/counts per revolution must be in the range of 1/32,767 < steps/counts < 32,767. An incorrect counts to steps ratio can result in failure to reach the target position and erroneous closed-loop stepper operation.
    I am verry sorry I have too many questions!
    I am very appreciate for your kingly help!Thanks again!
    EnquanLi
    China
    Striving is without limit!

  • Hi, I have answered no to the question about saving password for one spesific site. I have changed my mind and would like Firefox to save the password. How do I reactivate the password saver for one spesific site?

    Hi, I have answered no to the question about saving password for one spesific site. I have changed my mind and would like Firefox to save the password. How do I reactivate the password saver for one spesific site?

    Check exception list of your Firefox password Manager and check if your site is there or not?
    * http://kb.mozillazine.org/User_name_and_password_not_remembered#Password_Manager_settings

  • 2 questions about SmartWare (password protection, resume after standby)..

    Hi guys, 2 quick questions about the SmartWare utility. I have searched for previous answers, but couldn't find any. Might be that I uses the wrong search terms though, so sorry in advance if this had been asked (and aswered) before. When I create a backup, it is being stored file-by-file in the "SmartWare" folder on the NAS. Since the SmartWare folder is public, all users with access to the drive can access this folder. Ultimately this means that ALL users of the drive can access the backup files of ANY user. If someone performs a full backup, this means that anyone has access to ALL the data of that person. I could't find any option in SmartWare to password-protect backups or something. From a security point of view, I would consider this as a worst-case scenario. Even worse is that there is no mentioning of this in the user's manual. Am I missing something here? Is there a way to protect backups against access by any other user? If this is really not possible, I would consider this application to be pretty much useless, to say the least. "Dangerous" would be a better description... My 2nd question is only relevant if there's a solution for the first one, because else I would't use this tool anyway: Does it automatically resume a backup if the machine is put to standby or hibernation mode during a backup operation, or will it restart from the start, or will the backup be interrupted (and thus useless)? Many thanks in advance!

    One can create a Private Share on the WD My Cloud, configure it so only one user has access (password protected), then one can configure the SmartWare software to backup to that private share folder. One changes the backup location in the SmartWare program by selecting the dropdown selector box below the "WD My Cloud" on the Smartware "Home" screen. The Smartware User Manual explains this process under Chapter 5, Backing up Files, step 2, substep c. Smartware should resume the backup when ever it is interrupted. Here is how it is explained in the Smartware User Manual:Note: Backup protection is automatic for as long as the backup source and target devices are connected to your computer. Then, whenever you disconnect and reconnect either device, the WD SmartWare software rescans the backup source device for new or changed files and resumes automatic backup protection. 

  • Question about using passwords on Visio

    I have another question about the Vision:M. I was curious if you're able to password protect certain folders so that in order to access them, you have to put in a password. I know you can password protect files so it can't be messed with or whatever, but it doesn't stop the files from being viewed. Is there any way to do this?

    jessevsm wrote:
    I have another question about the Vision:M. I was curious if you're able to password protect certain folders so that in order to access them, you have to put in a password. I know you can password protect files so it can't be messed with or whatever, but it doesn't stop the files from being viewed. Is there any way to do this?
    there is an option somewhere in the settings menu to hide protected files, so you can't see them or edit them till the password is entered.

  • I have a question about Configuration of Post with Clearing

    I have a question about confiruation of the post with clearing which is t-doce 'FB05'.
    When I make post with clearing on 'FB05', I can change the additional selections.
    Where can I control the confiruation of the additional selections in t-code 'FB05'
    Please, tell me the menu path.

    Hi,
    In SPRO, go to
    Financial Accounting (New) > Accounts Receivable and Accounts Payable > Business Transactions > Incoming Payments > Manual Incoming Payments > Make Settings for Processing Open Items > Choose Selection Fields
    Hope this helps.
    Thanks

  • Question about configurations in Old Server

    Dear All,,
    I have a Question !
    How will you find what are the configuration are in a server.. for example..
    Is the DB configured RAC or DATA guard ?
    Is RMAN configured or not ?
    because at any time we have to face this request for Client who they don't have details regarding their Server,, (in Old Support Projects).
    if i have a plan for a upgradation of database what are the documents i have to prepare and what are the steps i have to take at initial stage !
    Regards
    HAMEED

    Hameed,
    This should be documented and those documents should be provided by the clients.
    You could do some investigation but again this will not be correct or complete without the documentation. For example, for RAC you could query the dynamic views (gv$instance, v$instance on each node) but this assume you already know what servers are configured. Or, you could refer to the RAC/DataGuard/RMAN configuration MOS docs for Oracle E-Business Suite and go through the steps to verify if those configurations are presented or not.
    Thanks,
    Hussein

  • Question about configuring REST web service in EBS instance

    I am from EBS SCM team. From one wiki page, it says OA Framework provides REST framework to expose OAF BC4J objects as web services. Can you provide more details about how to configure REST web service for one EBS instance? Any related information is also helpful.
    Edited by: 936859 on Sep 7, 2012 5:45 PM

    IIRC you must activate PAPI-WS for the engine. In Studio you do it by right-clicking on the project, then "engine preferences". In enterprise/standalone you must activate PAPI-WS in the Admin Center.

  • The question about configuration Organization Unit on spro

    Dear all.
    I want to configuration Organization Unit on spro so I have created O.Units, Jobs and positions on Personnel Administration->Organizational Assignment->Organizational Plan  but I can't see these values about O.Unit, job and position on  SAP Access Easy .
    How to see these values on  SAP Access Easy ?
    Can I input these values about O.Units, Jobs and positions on spro ?
    Thanks so much.
    Huyen Nguyen

    instead of that
    Define the Number ranges
    in OOCR
    for all the objects
    Make a Template for Objects and Object Id
    and upload the same thru PP01
    than all the enties will sit in the SPRO
    >note it is not mandatory to create thru SRPO wht in case if u have 4000 to 5000  Employees
    So the best way is upload the Data thru LSMW thru Proper objects and Relatioships

  • Questions about configuring sshd

    I checked the server admin manual and didn't find much detail on this topic. I took a look at the man page for sshd, but didn't really understand everything I read. Hoping someone here can help me understand how to configure sshd in OSX. I'm pretty new to OSX, but I have some experience working with Linux hosts. Working with sshd seems a little different on OSX.
    I need to adjust the system wide setting to timeout inactive SSH sessions. Currently a stale session will hang open for ever. I need to set the timeout to 15 minutes. Where/How is this done? Is this done in /etc/ssh_config by setting a value for "ConnectTimeout?" Is this seconds or minutes?
    How do you restart sshd after making changes to the config?
    What is the difference between /etc/ssh_config and /etc/sshd_config?

    First off, there are two config files of interest here:
    /etc/ssh_config - configuration file for the ssh client
    /etc/sshd_config - configuration file for the ssh server
    If you make a change to sshd_config then the change will apply to all connections made to this server. Making changes to ssh_config affect outgoing connections initiated by this machine.
    So the first question is which file to edit.
    If you want to control this at the server side (so idle connections are terminated by the server) then edit /etc/sshd_config.
    All the options are covered in the sshd_config man page:
    # man sshd_config
    Specifically, I think you're looking for a combination of ClientAliveInterval and ClientAliveCountMax.
    ClientAliveInterval sets how frequently SSHD checks the client connection. If ClientAliveCountMax tests are performed without any response the connection is closed.
    So, for your 15 minute disconnect you could set the ClientAliveInterval to 300 (5 minutes = 300 seconds), with a ClientAliveCountMax set to 3 (you don't want to set it to 15 minutes/1 Max since any temporary network delay could cause the connection to drop).
    To control this from the client side, the corresponding parameters to add to /etc/ssh_config are ServerAliveInterval and ServerAliveCountMax.
    How do you restart sshd after making changes to the config?
    Changes are dynamic, and applied to each new connection (i.e. the next time you log in it will use the current sshconfig/sshdconfig settings).

  • Question about configuration of NAT on ASA

    Hi all,
    I have ASA config with DHCP and its providing IP to users.
    ASA is connected to 3550 switch it has direct connection or say default static route
    From 3550 switch  connection goes to Router and it does the NAT   and has connection to outside world.
    My question is do i need to configure the NAT inside  and global (outside ) on the ASA  or not?
    As per my understanding NAT is done by router which has connection to ISP.
    Thanks
    Mahesh

    Hi Jennifer,
    Thanks for replied.
    I tested like this  config the NAT on ASA 
    then as per your reply run the command no nat-control as ASA ver is 8.4
    But nat config is still there in ASA.
    I did sh xlate it shows
    ciscoasa# sh xlate
    27 in use, 371 most used
    PAT Global 192.168.11.2(33396) Local 192.168.1.5(57177)
    PAT Global 192.168.11.2(61657) Local 192.168.1.5(57176)
    PAT Global 192.168.11.2(52259) Local 192.168.1.5(57175)
    PAT Global 192.168.11.2(30453) Local 192.168.1.5(57174)
    I did clear xlate still there is output from the sh xlate
    My question is how we test that ASA is nating or not ?
    Which commands can tell us that ASA is doing NAT ?
    Thanks
    MAhesh

  • Question about configuring Etherchannel on Catlyst 3750

    Hi, I have a stack witch catalyst 3750, I mean I have 3 switches ( 1 master, 2 slaves)
    My question
    Can I configure an etherchannel having 2 interfaces on each switch?
    How can I do this?
    Thanks
    Regards

    If you have a stack it should present itself as a single switch just put channel-group 1 desirable nonsilent if you are going to another cisco on each of the interfaces you want in the channel . this is for a layer 2 etherchannel . For a layer 3 etherchannel is somewhat more involved and too long to write here , just go to the cisco.com site and search on configuring etherchannels,3750 .

  • Adobe Reader Question about protected password

    I have adobe reader on my computer and I need to email an pdf file and password protect it, is that possible with the reader version?

    Kimberly,
    Moving this question to the Adobe Acrobat forum, since it's not related to CreatePDF.
    No, you cannot password protect a PDF with Reader. This requires Adobe Acrobat. See the "Protect" section here. A trial is here.
    Dave

  • Equium L10-300 - Question about BIOS password

    Hey all hope you can help a new user please.
    Had a customer bring in an Equium L10-300 notebook. Somehow a password has been put on the BIOS and the boot up so I cannot do anything with it. I cannot boot from a CD and Ive tried a USB floppy, it looks at the floppy once and then just carries on to the password area. I was going to attempt a BIOS flash you see.
    Im guessing maybe taking the bios battery out might help? But not sure where it is or how to get to it. Any links to manuals etc would be nice. Ive read that some newer Toshibas have special security chips now that hold the passwords etc.
    Any help would be great thanks, really need to get this fixed.
    Mark

    Hello Mark
    If you have customer I presume you work for one authorized service. The fact is that every authorized service has exact description how to remove BIOS password on each notebook model.
    So if you are trying to remove BIOS password I cannot imagine you work for some baker. So much about your job.
    Other important thing is that BIOS removal procedure is kind of top secret information and cannot be theme for public discussion. This information cannot be posted here. This will be great help for all people who try to enter stolen notebooks. Do you agree with me?
    If your customer needs professional help send him to nearest Toshiba authorized service provider. They will know how to remove BIOS password.

  • Question about configuration (ATI 5770) w/ 3 monitors

    Ok I already know how to get three monitors running on the ATI 5770.  I have one native mini DisplayPort, one mini DisplyPort to VGA and one native  DVI or DVI to HDMI.  What I need to know (before I buy another native mini DisplayPort monitor) is if the 5770 can run two native mini displayPort monitors and a native DVI?  Has anyone done this?

    i am currently running 3 displays on my macpro 1,1 with a 5770 card. here is my setup
    mini display port to dvi (dual link active from monoprice) to an Acer 24" monitor
    mini display port to dvi (sme as about) to and dvi to hdmi adapter to 65" 1080i television
    dvi port to Acer 24" monitor.
    i have to set it up this way because if i set both monitors to mini display port adapters and the tv to the dvi to hdmi adapter one of the monitors will not come on. setting it this way all three monitors are working. the only problem that i have is that my tv monitor flickers like the computer is refinding it all the time. i haven't really had a chance to look into it too much, but i can tell you that without the active link adapters only two of the three connections will work at one time.
    hope this helps