Quick Edit mode with Aperture

Using Elements 11 as an external editor for Aperture. In Quick mode the changes are not saved to Aperture. Expert mode works fine and Quick worked ok using Elements 9, What's up with the new program?

Hi , 
It's by design that the Managed Metadata column in Quick Edit doesn't support the data paste from excel and will display this
validation message.
It seems you would use the third party tool suggested by teylyn to bulk update the list Managed Metadata column vallues as a workaround per the following similar
post.
Thanks
Daniel Yang
TechNet Community Support

Similar Messages

  • How to get out of tex edit mode with a single button?

    Hey,
    Is there a way to escape from text edit mode with a single click or button?
    So far I always hit CTRL+Enter, then V and then I click away from the canvas so that the paragraph ain't higlighted no more. But thats a pain in the butt! Cant there be a single button for this?
    Thaks
    AO

    Something interesting I just noticed: Double-clicking outside a text box can have different effects according to context.
    With the Pointer tool selected, double-clicking on a text box allows you to edit the text. In this "quick edit" mode, double-clicking outside the text box will return you to the Pointer tool.
    If the Text tool has been selected manually, double-clicking outside a text box will create a new text box.

  • The error message "No more virtual tiles can be allocated" appears when I try to use the effects in the quick editing mode in my Elements 13. The baton OK has to be pressed several times for loading all effect patterns. The error returns when selecting th

    The error message "No more virtual tiles can be allocated" appears when I try to use the effects in the quick editing mode in my Elements 13. The baton OK has to be pressed several times for loading all effect patterns. The error returns when selecting the particular pattern.
    The problem does not appear, if PH Elements 13 is executed in the administrator mode.
    The available computer resources are rather  large enough: CPU INTEL i7 4 cores,  16GB RAM, 1TB HDD + 32GB SSD, Windows 8.1.
    Please, advice how to solve this problem? Maybe, there is patch or updating available?

    Dear n_pane,
    Thank you for the quick answer. In the meantime I found other way to pass by the problem. I increased the cache level up to the maximum value 8.
    The errors reported as "No more virtual tiles can be allocated" vanish, but I still do not understand, why PSE 13 cannot work properly by the lower cache levels, having available maximum resources it needed (10443 MB RAM and 26.53GB SSD space for scratches), or cannot collaborate with the fast SSDs properly.
    I wish you all the best in the New Year 2015!

  • Urg:Dos windows settings (Quick Edit Mode)

    Hi All
    I want to disable the DOS Windows Quick Edit Mode settings while launching my Java application.Is there anyway so that I can disable the DOS windows Quick Edit Mode settings from command while running my Java Program.This is reqd as my java application hangs and keeps waiting if someone presses mouse click for copying in the dos window.
    Any help apprecaiated
    thx
    Raj

    Hi
    With javaw the dos console still comes up for the first time and if i close it the javaw.exe keeps running in the background.
    So I would expect that dos console not come up for the first time also.Also when I use javaw -help it gives me an error pop up message.
    By the way I modified the sortcut batch file for my java appln and then in the dos window the qick edit mode is disabled.
    If u have any other idea its apprecaited
    Thx
    Raj

  • File too large for quick edit mode

    just bought a 12 mega pixil camera. using the photoshop album has been great until now. i can not use the files for quick edit. i can import the files from my camera after doing the recomended steps but in quick edit mode i am not able to do anything with the files. I can totogglento CS and that's the only way to do any editing but it is time consuming. After a wedding i have about 2000 photos to edit and it's just fufrustratingo have to toggle each time for a quick fix like auto balance, i have 1G of RAM and i have version 3 and have had no luck.
    Thank you for your help. if you have been successful in editing a 12 megapixil file please let me know....
    Zoya

    More information on this issue....
    I am importing them as JPEG.
    I have cropped the photos by 1/100th of it's original size so by definition i am reducing the pixels.
    ie, original jpg file is 3.5 MG photo:4368x2912 file type is jpg
    camera canon eos 5d
    error message is: "the photo you are tying to edit is too large and cannot be eidited. please try usign adobe photoshop or adobe photoshop element s to eidt this photo."

  • Quick Edit Mode and InfoPath form

    I have a SharePoint list that has a InfoPath customized form.
    The InfoPath form has two drop down fields that have a Data Connection to a another support SharePoint list
    The connection allows the second drop down list to be filtered by what the user chooses in the first drop down list (cascading fields).
    The data in the support SharePoint list is updated.
    If a user edits an item using the InfoPath form all is good BUT if a user edits an item in the Quick edit mode the drop down list fields are not updated with the changes in the support list.
    I think this is because if InfoPath is not used the data connection is not invoked and the support list changes are not pushed down to the consuming SharePoint list.
    Is there anyway a user can edit an item directly in the SharePoint list and still get the data updated in support lists that use a data connection in the InfoPath form?

    Hi,
    Yes,it is by default that the Quick Edit feature cannot consume InfoPath data connection. Cascaded Lookup function is not supported on Quick Edit Mode in SharePoint 2013.
    As far as I know, there is no solution to enable cascaded lookup function on Quick Edit Mode.
    For more information, you can have a look at the blog:
    https://spservices.codeplex.com/discussions/457245
    http://www.codeproject.com/Tips/758909/Two-Level-Cascading-Drop-Down-in-SharePoint-using?msg=4849625#xx4849625xx
    Best Regards,
    Eric
    TechNet Community Support
    Please remember to mark the replies as answers if they help, and unmark the answers if they provide no help. If you have feedback for TechNet Support, contact
    [email protected]

  • How to get the view in editable mode with OCA button.

    Dear Experties,
    I am new to CRM WEB UI ,I have got the requirement to develope a view with OCA button on it and when i click on the button it should direct to the second view  and it should open with edit mode.
    The Source view is table type and target view is form type.
    I am able to achieve this but unable to get it in editable mode.
    I have added the below code in do_prep_output method but getting dump  at the line
    lr_entity ?= me->typed_context->EMAINLEG->collection_wrapper->get_first( ).
    The error message is
    Long text During a 'CAST' operation ('?=' oder 'MOVE ? TO')a type conflict occurred. The source type '\CLASS=CL_BSP_WD_MIXED_NODE' is not compatible for assigning with the target type '\CLASS=CL_CRM_BOL_ENTITY'.
    Please somebody help me on this
    lv_display = me->view_group_context->is_view_in_display_mode( me ).
      IF lv_display EQ abap_false.
      ELSE.
         me->view_group_context->set_view_editable( me ).
      ENDIF.
      DATA:    lr_tx           TYPE REF TO if_bol_transaction_context,
              lr_entity       TYPE REF TO cl_crm_bol_entity,
               lr_comp type REF TO ZL_BT131QI__BSPWDCOMPONEN_IMPL.
      lr_comp ?= me->comp_controller.
      Check lr_comp is BOUND.
      lr_entity ?= lr_comp->typed_context->BTADMINI->collection_wrapper->get_current( ).
      CHECK lr_entity IS BOUND.
      IF lr_entity->lock( ) = abap_true.
        me->view_group_context->set_view_editable( me ).
      ENDIF.
      lr_entity ?= me->typed_context->EMAINLEG->collection_wrapper->get_first( ).
      WHILE lr_entity IS BOUND.
        lr_entity->lock( ).
        lr_entity ?= me->typed_context->EMAINLEG->collection_wrapper->get_next( ).
      ENDWHILE.
    The following error text was processed in the system:
    Source type \CLASS=CL_BSP_WD_MIXED_NODE is not compatible, for the purposes of assignment, with target type \CLASS=CL_CRM_BOL_ENTITY
    Exception Class CX_SY_MOVE_CAST_ERROR
    Error Name MOVE_CAST_ERROR
    Program ZL_ZBT131QI_EMAINLEG_IMPL=====CP
    Include ZL_ZBT131QI_EMAINLEG_IMPL=====CM00C
    ABAP Class ZL_ZBT131QI_EMAINLEG_IMPL
    Method EH_ON_EDIT
    Line 33 
    Long text During a 'CAST' operation ('?=' oder 'MOVE ? TO')a type conflict occurred. The source type '\CLASS=CL_BSP_WD_MIXED_NODE' is not compatible for assigning with the target type '\CLASS=CL_CRM_BOL_ENTITY'.
    Thanks in advance!!!

    Hi,
    in CRM a context can consist of model nodes,  value nodes and, unfortunately, mixed nodes. While mixed nodes implement the same interface as model nodes they can't be casted into a CL_CRM_BOL_ENTITY directly. Instead you need to perform the following conversion in order to get the model node from the mixed node:
    DATA:  mixed_node     TYPE REF TO cl_bsp_wd_mixed_node,
               entity              TYPE REF TO cl_crm_bol_entity.
    mixed_node = me->typed_context->EMAINLEG->collection_wrapper->get_first( ).
    entity = ?= mixed_node->if_bsp_wd_ext_property_access~get_model_node( ).
    Best,
    Christian

  • In List, How to modify the Link in Quick Edit Mode?

    In List, How to modify the Edit in Quic Mode Link? Instead of opening Quick view mode, to open in InfoPath customized form?

    Hi Eugene,
    According to your description, my understanding is that you want to midify the link of "Edit" and set it linking to a InfoPath Form which can bulk edit your List.
    You can use the code above to modify the Edit's hyperlink and set it linking to your InfoPath form.
    <script src="http://code.jquery.com/jquery-1.10.2.min.js" type="text/javascript"></script>
    <script type="text/javascript">
    $(document).ready(function () {
    $("#idHomePageNewItem").next("a").attr("href","the URL of your InfoPath form");
    $("#idHomePageNewItem").next("a").removeAttr("onclick");
    </script>
    For more information about bulk updating a SharePoint list using InfoPath form, you can have a look at the blog:
    https://social.msdn.microsoft.com/Forums/sharepoint/en-US/c05983fc-d992-49ff-8d18-fa8f70777d66/using-infopath-2010-to-bulk-update-a-sharepoint-list?forum=sharepointcustomizationprevious
    http://infopath.wordpress.com/2013/09/23/infopath-repeating-table-add-edit-delete-sharepoint-list-items-bulk/
    http://sharepointknowledgebase.blogspot.com/2011/10/updating-sharepoint-list-by-using.html#.VGFsKHkcSM8
    If any misunstanding, please feel free reminding me and provide more detail for your issue.
    Best Regards,
    Eric
    Eric Tao
    TechNet Community Support

  • Why is the photo only black in Edit mode with iPhoto 11?

    Why is the photo only Black in Edit mode?
    Everything works fine, except when I try to edit a photo, it shows as only Black.
    I have tried every fix talked about on this forum, and some others - nothing fixes it.
    Is this a Feature ? or is it a bug that no one is interesteed in fixing? It doesn't fill me with confidence in Apple when I see such random little glitches remaining unfixed.

    Is it the same for newly created slideshows?  Although a long shot give this a try:
    1 - delete the iPhoto preference file, com.apple.iPhoto.plist, that resides in your
         User/Home/Library/ Preferences folder.
    2 - delete iPhoto's cache file, Cache.db, that is located in your
    User/Home/Library/Caches/com.apple.iPhoto folder (Snow Leopard and Earlier).
    or with Lion and Mt. Lion from the User/Library/Containers/com.apple.iPhoto/
    Data/Library/Caches/com.apple.iPhoto folder
    3 - launch iPhoto and try again.
    NOTE 1: If you're moved your library from its default location in your Home/Pictures folder you will have to point iPhoto to its new location when you next open iPhoto by holding down the Option key when launching iPhoto.  You'll also have to reset the iPhoto's various preferences.
    NOTE 2:  In Lion and Mountain Lion the Library folder is now invisible. To make it permanently visible enter the following in the Terminal application window: chflags nohidden ~/Library and hit the Enter button - 10.7: Un-hide the User Library folder.
    If the above fails as a test launch iPhoto with the Option key held down and create a new, test library.  Import some photos and test to see if the same problem persists. Does it?
    If it doesn't then the following my be your next step:
    Starting over from scratch with new library
    Start over with a new library and import the Originals (iPhoto 09 and earlier) or the Masters (iPhoto 11) folder from your original library as follows:
    1. Open the library package like this.
    2. Launch iPhoto with the Option key held down and, when asked, select the option to create a new library.
    3. Drag the subfolders of the Originals (iPhoto 09 and earlier) or the Masters (iPhoto 11) folder from the open iPhoto Library package into the open iPhoto window a few at a time.
    This will create a new library with the same Events (but not necessarily the same Event names) as the original library but will not keep the metadata, albums, books slideshows and other projects.
    Note:  your current library will be left untouched for further attempts at a fix if so desired.

  • Table in edit Mode with infinite lines ?

    Hi,
    We are designing an application, where as one of the requirement is to have a table with infinite open lines for user input.
    By Default table should be in EDIT mode and user should be able to enter values without the need to click on a line to insert a new row every time he/she wants to input a value.
    How can we acheive this requirement in WDA. In classical dynpro it is very easy to do this.. but I am struggling to find a way around for this..
    Thanks in advance.
    Regards
    Rohit Chowdhary

    Hi Rohit,
    >My experience with tables that are over 1000 lines, showed performance and
    >even stability issues for IE.
    I can only emphasize what Phil said. Especially, in your case with an editable table, displaying more than 50 rows at a time (depending on the number of columns) can cause a bad user experience, because the browser needs to handle all the html and javascript we throw at it.
    Imho there are two solutions:
    (a) Try to use the ALV
    (b) In case you would like to use the table ui element, you could add enough empty context elements to the context node where the table binds to, so that a user has always plenty of empty rows available. A toolbar button could provide the user with more initial lines.
    Best regards,
    Thomas

  • "Bad" colors/banding when going into Edit mode with Canon RAW files

    Just got my iLife '06 suite yesterday and ran into something very disturbing: something wrongwith the colors of RAW files once you go into editing mode. In the library view, they're fine. Try to edit one, and after a few seconds, there's a final refresh of the image window that heavily alters and bands the colors. (Looks almost like a poor conversion down to 256 colors or less - it's that bad).
    This is happening on Canon 300D and 20D raw files, and did NOT happen with iPhoto 5. The RAW files open up and display just fine in Preview (as well as 3rd party apps) - problem is in iPhoto 6 only. I've already sent in a bug report - has anyone else tried double-clicking on a RAW file to go into Edit mode yet?
    David Miller

    I use Huey from Pantone to calibrate my monitor for consistancy in different lighting situations and across applications. But the same effect happens by choosing any one of the non-standard monitor calibrations.
    Try this:
    Choose a RAW photo and monitor calibratioin that causes the banding and discoloration.
    Open the RAW photo in Edit mode and wait the couple of seconds for banding to appear.
    Next, adjust the image size slider so that scroll bars appear at the bottom and right side of the photo. It doesn't take much. Notice the banding disappears!
    Now grab one of the scroll bars and move it. Observe the banding and discoloration. And, when you release the scroll bar the banding disappears again.
    I don't remember this happening with iPhoto 5.
    I think it has something to do with the display
    calibration. After I first saw this I switched back
    to my default iMac G4 profile, and the problem wasn't
    there anymore. I'm not sure what the difference is. I
    set up several different profiles, each with
    different choices for Advanced, White Point and
    Gamma, and some trigger this banding, and some do
    not.
    Anybody have any similar experiences?

  • Change edit mode with clasic FM REUSE_ALV_GRID_DISPLAY

    Hello,
    I'm using the function "REUSE_ALV_GRID_DISPLAY", in the classic method. I want to switch from display to edit mode when the user press the edit mode button. But I don't get it to work.
    So far as I know building up the ALV is correct so I don't put all the source code here.
    What's wrong in my code?
    FORM BUILD_ALV_REPORT.
    perform build_field_cat.
    After building the field catalog (e.g., from a DDIC structure), we can
    modify these settings in the following subroutine.
    PERFORM modify_fieldcatalog.
    IF Not fieldcatalog is initial.
    perform collect_data
    TABLES it_collector
    USING werks
    lgort
    s_jaar
    s_mnd.
    PERFORM t_sort_build USING gd_sort.
    perform build_layout CHANGING gd_layout.
    Table ta_comment is used to display header information in the
    top-of-page of the ALV output.
    PERFORM build_comment CHANGING ta_comment[].
    Table gd_tab_group wordt gebruikt om een groepering op te bouwen.
    PERFORM build_group CHANGING gd_tab_group[].
    SET PF-STATUS 'STANDARD_FULLSCREEN'.
    gx_variant-report = gd_repid.
    CALL FUNCTION 'REUSE_ALV_VARIANT_DEFAULT_GET'
    EXPORTING
    I_SAVE = 'A'
    CHANGING
    CS_VARIANT = gx_variant
    EXCEPTIONS
    WRONG_INPUT = 1
    NOT_FOUND = 2
    PROGRAM_ERROR = 3
    OTHERS = 4.
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
    EXPORTING
    I_CALLBACK_PROGRAM = gd_repid
    I_CALLBACK_PF_STATUS_SET = 'STANDARD_FULLSCREEN'
    I_CALLBACK_USER_COMMAND = 'R1_PROCESS_USER_COMMAND'
    I_CALLBACK_TOP_OF_PAGE = co_rout_top_of_page
    I_BACKGROUND_ID = 'ALV_BACKGROUND'
    I_GRID_TITLE = 'Lijst goedgekeurde ATBs'
    I_GRID_SETTINGS =
    IS_LAYOUT = gd_layout
    IT_FIELDCAT = fieldcatalog
    IT_EXCLUDING =
    IT_SPECIAL_GROUPS = gd_tab_group[]
    IT_SORT = gd_sort[]
    I_SAVE = 'A'
    IS_VARIANT = gx_variant
    I_SCREEN_START_COLUMN = 0
    TABLES
    T_OUTTAB = it_collector
    EXCEPTIONS
    PROGRAM_ERROR = 1
    OTHERS = 2
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    ENDIF.
    SET PF-STATUS 'xxxxxxxx'.
    SET TITLEBAR 'xxx'.
    ENDFORM. " BUILD_ALV_REPORT
    Setting the column to edit mode
    ls_fieldcat-fieldname = '3_ATWRT'.
    ls_fieldcat-seltext_m = 'WBS-NRG'.
    ls_fieldcat-seltext_l = 'WBS-element NRG'.
    ls_fieldcat-row_pos = 0.
    ls_fieldcat-col_pos = 30.
    ls_fieldcat-outputlen = 4.
    ls_fieldcat-emphasize = 'X'.
    ls_fieldcat-key = 'X'.
    ls_fieldcat-do_sum = 'X'.
    ls_fieldcat-edit = 'X'.
    append ls_fieldcat to fieldcatalog.
    clear ls_fieldcat.
    ENDFORM. " modify_fieldcatalog
    FORM r1_process_user_command "#EC CALLED
    USING utp_ucomm TYPE syucomm
    utp_selfield TYPE slis_selfield.
    DATA: ltp_repid TYPE syrepid.
    Handle the specific user-commands.
    CASE utp_ucomm.
    Handle double click or hotspot on a specific field. *
    These are some examples *
    WHEN co_double_click.
    WHEN OTHERS.
    ENDCASE.
    WHEN 'SWITCH'.
    IF V_EDIT = ' '.
    V_EDIT = 'X'.
    ELSE.
    V_EDIT = ' '.
    ENDIF.
    PERFORM modify_edit_mode.
    utp_selfield-refresh = 'X'.
    WHEN OTHERS.
    ENDCASE.
    ENDFORM. "R1_PROCESS_USER_COMMAND
    FORM modify_edit_mode .
    DATA: ls_fieldcat TYPE slis_fieldcat_alv.
    LOOP AT fieldcatalog into ls_fieldcat.
    CASE ls_fieldcat-FIELDNAME.
    WHEN '3_ATWRT'.
    ls_fieldcat-edit = V_EDIT.
    gd_layout-edit = V_EDIT.
    gd_layout-edit_mode = V_EDIT.
    ENDCASE.
    modify fieldcatalog from ls_fieldcat.
    clear ls_fieldcat.
    ENDLOOP.
    ENDFORM. " modify_edit_mode

    Vasanth,
    This is what I'm already doing in the program by setting the edit mode for the column '3_ATWRT'. But I want to switch from edit to display mode and back again. This is not working. Only when I buildup the fieldcatalog this is working?
    Kind regards,
    Richard Meijn

  • Cannot use edit mode with zebra layout in alv

    Hi,
    I am using 'REUSE_ALV_GRID_DISPLAY' for the ALV genration,
    I found that I cannot use
              it_layout-edit_mode = 'X'.
              it_layout-zebra = 'X'.
    simultaneously..
    Only zebra layout come up and not the edit mode...
    Is there a wrk around to solve this
    Thank you,
    Arjun.G

    try removing
    it_layout-edit_mode = 'X'.
    from ur code..
    and add
    is_fieldcat-edit = 'X'   " for all columns...

  • Editing photos with Aperture....how to...?

    Ok so I have two photos, I want to put them both together...one completes the other or is a continuation...how in heavens do I do this with Aperture? can I even do this? I am used to photoshop...I am not sure how to go about combining two photographs into one. Please help!!!!

    That is not a feature of Aperture - you need a third party editor like Photoshop or PS Elements - or search MacUpdate or version tracker
    LN

  • Totals Missing from Datasheet (Quick Edit) Mode

    After migrating a site to 2013, there are issues with Datasheet Mode. There were Totals at the end of a few columns on it but now they are missing. I have tried re-creating the views etc and turning off and on the Totals options on the columns but they are
    still missing. This is a massive problem for a lot of our users. Has anyone got any ideas on how to switch these back on? Thanks

    Hi,
    Please go to edit view page of datasheet view > Totals > select the total you would like to display for this list.
    Regards,
    Rebecca Tu
    TechNet Community Support

Maybe you are looking for