R/3 database monitoring through RFC

I have code which monitor database.
There are two servers, one is XID and other is ECD. Messages are flowing from ECD to XID.
Code is uploaded in XID server .Code monitor XID database .code hits Standard Sap table i.e. SXMSPMAST, check entries and send alert as per condition.
ECD server requires to monitor ECD database by using same code existing in XID.
ECD server wonu2019t allow deploying code.
Requirement is as follows.
1) Convert code (Existing in XID) into RFC.
2) Call this RFC from ECD server.
3) Pass server name u2018ECDu2019 as import parameter to RFC.
5) Monitor ECD database using same piece of code (Via RFC).
Let me know whether it is possible to monitor R/3 database using RFC?
If possible then what are mandatory object I need to add in RFC?

close

Similar Messages

  • Change database entry through RFC

    how I can change my database entry from RFC by one field as a importing parameter
    please help me out
    Moderator message : Not enough re-search before posting. Thread locked.
    Edited by: Vinod Kumar on Oct 22, 2011 11:15 PM

    close

  • Rz20 remote database monitoring

    Hi girus,
    we have to monitor from our Solution Manager a java remote database. We have followed note 1139623, everything works well in transaction DB02 for this remote system except Alert Monitor Tree under Folder Alert . The icons are inactive and are not showing data.
    We have already set flag "collect alert data" in transaction DBACOCKPIT.
    Any ideas?

    Hello,
    Could you please check note:
    1265134 - DBA Cockpit: Connecting a remote database
    1711688 - DBA Cockpit: RZ20 alerts are not generated
    868063 - Database space statistics monitor for Oracle
    1540222 - DBA Cockpit: Monitoring non-ABAP/Java Oracle databases
    If a database is installed on a remote server than the SAPLOCALHOST parameter should be maintained correctly in the agent profile, the value
    for this parameter should be exactly the same as the SAPDBHOST parameter value in the instance profile. If this is correctly done than in the
    transaction AL15 automatically the flag "DB server" will be selected for the related SAPCCMSR agent RFC destination (note 444947).
    1068204 -  New monitor template for database monitoring
    Monitoring Standalone DB Server using CCMS Agents
    http://scn.sap.com/community/netweaver-administrator/blog/2013/12/18/monitoring-standalone-db-server-using-ccms-agents
    BR
    T

  • Is it possible to use my ipad 4 as a second monitor through a USB connection.

    Is it possible to use my ipad 4 as a second monitor through a USB connection.

    perhaps, but my information was current. I had the same question and was looking for and answer and found it. So I responded in order to help others who found this question and were looking for an answer. This community is made more helpful and kept current by adding new answers with current information.
    imobl... air display was a valid response for 2011 predating the question. Also using Monitor2go was valid in 2012. There were USB mirroring and as a 2nd display for an iPad options at the time the original question was asked.

  • How do I get my Mac Pro to see the second monitor through a video splitter and/or switcher?

    In a recording studio we have a Mac Pro with two video display monitors in the control room and we want to be able to show the content of the second monitor to the person in the recording room on a big display monitor there. However, when we interpose a switcher or splitter between the computer and the second monitor so that we can (with a switcher) switch the second monitor signal from the control room monitor to the record room monitor or (with a splitter) split the signal to go to both monitors, we have no luck. On startup the computer does not see the monitor through the switcher, so it doesn't recognize its existence. If we start the computer up without the switcher in the signal chain, it sees the second monitor just fine, and (weirdly enough) we can then change the cabling to interpose the switch, which then works to switch back and forth between second monitors (control room and record room), but that cable swapping's a royal PITA. We want a simple solution that will allow us to start up the computer, see the second monitor in the control room, then choose to show it to the person in the record room with a simple flip of the switch (or even better, split the signal so it's available both places). The splitter we've tried most recently is this one: http://tinyurl.com/curen39 I'd appreciate any advice from people who have tried this configuration or something similar with success. We have a full ProTools HD Accel 3 system installed, so there's no room to install a second video card. Thanks.
    Mac Pro 8-Core 2.4 GHz, OS 10.6.8

    Christopher Dobrian wrote:
    Thanks for the response! Yes, it's a 5x70 video card, a 5770 I believe. In any case, it does have the three ports, but (a not-well documented fact) that doesn't mean one can really get three full-resolution signals out of it at one time, as you alluded to in your message. So, yes, we did try hooking all three up directly to the computer, but the computer would only recognize two of those monitors, and the only way to get it to "de-recognize" the second monitor and recognize the third monitor was to physically disconnect the second monitor.
    I did say when you want to connect three monitors to 5x70's there are some rules to adhere to.  These are covered in the first two apple docs mentioned above, or by title:
    Mac Pro (Mid 2010), Mac Pro (Early 2009): Issues with three displays and multiple DVI, HDMI connections
    Mac Pro (Early 2009), Mac Pro (Mid 2010): Supported display configurations
    The general gist of these rules is that to drive three monitor son a 5x70 you need two active adapters.  That is why one of your monitors was disabled when you tried to add a third. 
    Here's a good explanation of what's going in here and why you need two active adapters on these cards:
    Active vs. Passive Displayport adapters *the truth*
    If you use DVI monitors and any of them have resolutions less than 1920 x 1200 then you can use single link active adapters. The "AMD Eyefinity Validated Dongles" chart shows some active (and passive) adapters that are acceptable.  For example of a single link DVI active adapter is the Accell B087B-006B.  An example of a dual link DVI active adapter would be the one from monoprice.com if you need to connect monitors with a resolution greater than 1920 x 1200.
    I'm doubtful that SwitchResX would be able to convince the computer that there were only two monitors connected and direct the second monitor signal to the correct place, but it certainly seems worth a try, so thanks for the idea! Any other ideas are still welcome in the meantime.
    I'm not doubtful.  It is a very powerful utility for dealing with all aspects of multiple monitor configurations (they call them "Display Sets") complete with forcing EDID information if necessary.  The different configurations can be controlled with a (contextual) menu and/or hot key.
    SwitchResX is academic at this point if you want to have all three monitors connected.  You would need to get that working first.  Then use SwitchResX to vary the configuration combinations.  So if you go this route the "name of the game" is figure out the active adapters you need.
    I only described in general terms above about the adapters since you never said exactly what kind of connections these monitors require (single link DVI, dual link DVI, hdmi, mini-displayport, vga). 

  • File to RFC, and through RFC response i am trying to trigger the Mail adapt

    Hi All,
    Right now i am doing File to RFC, its working fine but now the requirement is when xi connect to ftp and picks the  file need to send one success mail after the file pickup and data sent to BW system again i need to send one mail and also error alerts to inbox.
    Till now i am not using BPM, can we do this without BPM pls let me know
    now i am trying to achieve this in File to RFC, and through RFC response i am trying to trigger the Mail adapter.
    or else  i need use only BPM pls share  the steps which i need to be configure.
    Am i correct or pls suggest me some idea to achive this and also pls share some smaple ones in BPM .
    Thanks in advance
    Venkat

    With BPm, follow this:
    /people/arpit.seth/blog/2005/06/27/rfc-scenario-using-bpm--starter-kit
    Instead of receiving the response in file, use mail adapter
    Regards,
    Prateek

  • Third party system call function module/BAPI through RFC to update Z table

    Dear Friends,
    We have a third party system which directly inserts a Z table in SAP through its programming, which is an auditing issue.
    We want the third party system should call function module/BAPI through RFC so that the Z table gets updated.
    waiting for inputs..
    Thanks,
    Kumar

    if third party system is capable of making Remote Function call, then writing a Function module & making it remote enable is not difficult task in ABAP.
    You may have to prepare specifications first to decide if third party system is going to Read, insert, update, delete records from Zee table.

  • Viewing Canvas Video Feed on a Seperate Monitor through DVI or Component

    Hey All,
    This is something I have been researching with no simple, possibly cost efficent solution. Basically I would like to view the timeline canvas feed on a seperate monitor without the use of my hvx200. I will be editing in 720p60 and have an 17" hd tv with component and dvi inputs on the way.
    I mainly will be using this monitor on productions as a field monitor but I would like to eventually use it as a second monitor on my mac pro to view only the video timeline feed of final cut pro on it, not mirror desktop and have a somewhat fuzzy (sd on a second monitor through mirroring always seems degraded).
    I have looked at possible devices like the matrox and blackmagics pci cards to either sdi (which I dont have) hdmi and such but those start at $1000, a great deal of money I do not have at the time.
    I would think that since the monitor has both a vga 15pin and digital dvi input there either has to be an option in fcp I have not seen or a device that I have not found.
    Any help would be greatly appreciated,
    Thanks again for everything,
    Tim

    Look at the back of your mac and see if you have two monitor ports on your video card. Depending on the type of card you should be able to connect to your HD monitor as a second screen and then setup FCP to put external video on the digital cinema desktop.
    I am using a siimilar setup, using a Dell Ultra-Sharp flatscreen as both my second computer monitor and my external video. The Dell's have DVI, VGA, component, S-video, and composite inputs, but right now I'm just using the DVI and FCP switches the video back and forth when I turn on external video.
    Hope this helps -
    Max Average

  • Call Transaction Through RFC

    Hi ,
    I am trying to do a call transaction through RFC call from a Middleware which is a CPIC user (only communication Non dialog User ) . 
    Call  transaction does gets executed without any error but it does not update any data.But when I run it through my user id it works absolutely fine .
    I am not sure what is causing the issue
    Security authorization?
    RFC through Non Dialog user ?
    Paramters missing in RFC  ?
    Paramatertes missing in call transaction option?
    If anyone of you has faced a similiar issue then please let me know the path forward.
    Thanks
    Vikas

    Hi Vikas,
        The problem is in Authorization? And check the mode of Process Synchoronus or asynchoronous? Both the RFC and CALL transaction should be Same /
    Thanks
    MAnju

  • Error in Database monitoring in Solution Manager Diagnostic

    Hello All,
    I'm facing issue in configuring Database monitoring for Java system (EP/PI) from Solution manager .
    It could be configured from sol man diagnostic>Diagnostic System>Managed system>Database monitoring, iei'm unable to have java system in DBACOCKPIT system .
    I can have connection as successful, but along with it i'm getting error as "Error in CL_DB6_SYS with return code ADBC error", for this issue, i got note # 1263152, i did applied this note, but still no success.
    I'm having Sol man system, which is on EHP1 SP2 and rest other java systems are at PI 7.1 & EP 7.0, database is Oracle 10.2.0.4.
    Please let me know, if anyone did face such kind of issue & solution for the same...
    Thanks
    Anand.

    I could solve this problem....latest kernel on managing & managed system is thumb rule for this.

  • Enabled monitor through override not visible in custom management pack

    Hello Everyone,
    I've this requirement to enable a monitor which is disabled by default in its source sealed management pack. Using following article; via override; I enable the monitor and place it into a custom unsealed management pack.
    https://technet.microsoft.com/en-au/library/hh212818.aspx
    Now when I try creating subscription based on that monitor; and select the custom unsealed management pack; that monitor is not listed/available. However, this same monitor which is turned enabled by override; is listed; if its parent sealed management pack
    is selected. 
    Questions:
    1) Would selecting this monitor from its sealed management pack; safe to assume this monitor is now enabled? 
    2) Is this default behavior for monitors turned enabled via override? 
    Please provide input to this, how an enabled monitor through override can be referenced to be used? Thank you.

    1) If the override is done properly, yes, it is enabled. You can check that it is actually enabled by opening the health explorer of an object targeted by this monitor : it should be green/yellow/red instead of blank when it was disabled
    2) It is the default behavior. What happens is that you store the override (just a parameter that says "ok, the monitor is now enabled") in the unsealed management pack, not a copy of the actual monitor.

  • Upload and Download file through RFC called by java

    We are trying to download/upload file through rfc function called by java(JCO),In the rfc function,we use WS_DOWNLOAD,but it does not work.
    Any one know about this,Please help ,thanks very much.
    Message was edited by: gw gw

    Hi gw,
    This question looks a little confusing to me.
    WS_DOWNLOAD is used to download files from SAP to the presentation server (your PC).  It will not work through RFC.
    BUT, also if you want to access a function module via RFC is must be RFC enabled (as Anand pointed out).
    AND WS_DOWNLOAD uses a PUSH approach.  It pushes a file to the PC from ABAP.  So even if the two points above weren't a problem it still would not be suitable for what you are doing.
    Perhaps you could explain a little what you are trying to achieve.
    Cheers,
    Brad

  • Spool Error Monitoring through CCMS not available in Standard Delivered MTE

    Hi Everyone,
    My Client requirement is to monitor SPOOL Errors through CCMS. But Standard Monitoring Tree Elements (MTEs) does not capture the Spool Errors .
    Can anybody Please let me know , How Can I setup Spool Error Monitoring through CCMS.
    Thanks & Regards
    Deepak Gosain

    Deepak,
    Check this One...
    //help.sap.com/saphelp_nw70/helpdata/en/34/658a3b15566262e10000000a11402f/content.htm]
    Hope this Helps....
    Happy Learning
    Chander N Purna

  • Using monitor through tape deck

    I want to use an LCD tv I have for an external video monitor. I have a Sony HVR-M15 deck connected by fire wire to my Mac. I have RCA, S-video and Component outputs on the deck. I can playback tapes on the external LCD monitor through the deck but how do I use it as a Full quality playback monitor in FCP?

    I can playback tapes on the external LCD monitor through the deck but how do I use it as a Full quality playback monitor in FCP?
    Isn't that what you're doing already?
    -DH

  • Why T430 connect with monitor through VGA can only have 60 fps refreash rate?

    I have a T430 and T420.
    When I connect the T420 with monitor through VGA, the refreash rate of the monitor can be 75 fps in 1600*900. But When I connect the T430 with the same monitor through VGA, the refresh rate can only be 60 fps, no 75 fps option in the list, Anybody has idea why it works like this?
    Thanks very much.

    Actually, on second thought, does the external monitor show up as "Generic PnP monitor" in Device Manager? Or does it show up as the correct model number?
    W520: i7-2720QM, Q2000M at 1080/688/1376, 21GB RAM, 500GB + 750GB HDD, FHD screen
    X61T: L7500, 3GB RAM, 500GB HDD, XGA screen, Ultrabase
    Y3P: 5Y70, 8GB RAM, 256GB SSD, QHD+ screen

Maybe you are looking for

  • BI portal error while trying to export to excel

    Hi All, In BI portal, I am getting an error message when trying to export the report to excel. Following is the error message: 500 Internal Server Error   BEx Web Application Failed to process request; contact your system administrator Information fo

  • How can i edit Iweb published page to open as a Popup?

    I want to edit my iWeb site so that when a link is clicked it opens a different page as a popup with no other toolbars, scrollbars etc - just the image i want to show. I found some code online (http://www.quackit.com/html/codes/html_popup_window_code

  • English version of Firefox in China

    I am an English speaker working and living in China. I just updated firefox (while on my VPN) for Windows 7 to Firefox 24 English version and I am now somehow running the Chinese version. I have uninstalled and reinstalled multiple times and checked

  • Dented Macbook Pro. Screen seems fine, but damamge in the future

    Okay, so this morning. I find my Macbook Pro on the ground, and unfortunately it had a small, (but deep) dent. It isn't touching the display, but every time I open and close the lid, and when it gets shaken up from typing, I can see the pressure mark

  • When is resetlogs option used in alter database

    Hi Could anybody explain when alter database open resetlogs statement is used? Thanks in advance