RD640 power supply monitoring ( WMI) status

hiFor RD640, if monitoring of the status of Power supply ( hot swap?)  need to be done, what is the WMI namespace/class/path that will return the status? I have already attempted to query by cim_powersupply but nothing returns.  wmic path cim_powersupply get *  Does easy manage monitors the power supply at all? Thanks     

hiFor RD640, if monitoring of the status of Power supply ( hot swap?)  need to be done, what is the WMI namespace/class/path that will return the status? I have already attempted to query by cim_powersupply but nothing returns.  wmic path cim_powersupply get *  Does easy manage monitors the power supply at all? Thanks     

Similar Messages

  • SNMP power supply monitoring an XR 12404

    I'm trying to monitor basic health status of the Power Supply on a 12404. However, I cannot find the relevant information from the ENTITY MIB or it's Cisco extensions.

    Thanks Joel. Here is the output from a walk of entPhysicalDescr:
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.1 = STRING: "Cisco 12404 80Gbps fabric"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.2 = STRING: "Line Card/RP slot "
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.3 = STRING: "Cisco 12000 Series Performance Route Processor  2"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.4 = STRING: "host__PLIM_V7_HDD_5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.5 = STRING: "host__PLIM_V6_1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.6 = STRING: "host__PLIM_V4_1.3V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.7 = STRING: "host__PLIM_V5_1.8V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.8 = STRING: "host__PLIM_V3_2.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.9 = STRING: "host__3.3V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.10 = STRING: "host__5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.11 = STRING: "host__Mbus5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.12 = STRING: "host__InletTemp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.13 = STRING: "host__HotTemp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.14 = STRING: "Line Card/RP slot "
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.15 = STRING: "Cisco 12000 Series - Multi-Service Blade "
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.16 = STRING: "host__12V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.17 = STRING: "host__0.75V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.18 = STRING: "host__1.2V_MPU"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.19 = STRING: "host__1.2V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.20 = STRING: "host__1.25V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.21 = STRING: "host__1.25V_IXP1"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.22 = STRING: "host__1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.23 = STRING: "host__MB_PLL_1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.24 = STRING: "host__1.8V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.25 = STRING: "host__2.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.26 = STRING: "host__3.3V_DB1_AUX"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.27 = STRING: "host__3.3V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.28 = STRING: "host__5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.29 = STRING: "host__Mbus5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.30 = STRING: "host__HotTemp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.31 = STRING: "host__InletTemp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.32 = STRING: "Line Card/RP slot "
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.33 = STRING: "Cisco 12000 Series - Multi-Service Blade "
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.34 = STRING: "host__12V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.35 = STRING: "host__0.75V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.36 = STRING: "host__1.2V_MPU"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.37 = STRING: "host__1.2V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.38 = STRING: "host__1.25V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.39 = STRING: "host__1.25V_IXP1"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.40 = STRING: "host__1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.41 = STRING: "host__MB_PLL_1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.42 = STRING: "host__1.8V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.43 = STRING: "host__2.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.44 = STRING: "host__3.3V_DB1_AUX"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.45 = STRING: "host__3.3V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.46 = STRING: "host__5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.47 = STRING: "host__Mbus5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.48 = STRING: "host__HotTemp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.49 = STRING: "host__InletTemp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.50 = STRING: "Line Card/RP slot "
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.51 = STRING: "Cisco 12000 Series SPA Interface Processor-  401"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.52 = STRING: "Shared Port Adapter(SPA) Bay"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.53 = STRING: "2-port Gigabit Ethernet Shared Port Adapter_V2"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.54 = STRING: "Shared Port Adapter(SPA) Port Slot"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.55 = STRING: "Shared Port Adapter(SPA) Port Slot"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.56 = STRING: "Shared Port Adapter(SPA) Bay"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.57 = STRING: "Shared Port Adapter(SPA) Bay"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.58 = STRING: "Shared Port Adapter(SPA) Bay"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.59 = STRING: "host__DtrCard_Tcam3"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.60 = STRING: "host__DtrCard_Tcam2"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.61 = STRING: "host__DtrCard_Tcam1"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.62 = STRING: "host__DtrCard_1.2Vs2"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.63 = STRING: "host__DtrCard_1.2Vs1"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.64 = STRING: "host__DtrCard_Wwolf"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.65 = STRING: "host__DtrCard_PLL"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.66 = STRING: "host__DtrCard_0.75V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.67 = STRING: "host__DtrCard_1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.68 = STRING: "host__DtrCard_1.8V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.69 = STRING: "host__DtrCard_1.25V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.70 = STRING: "host__DtrCard_2.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.71 = STRING: "host__DtrCard_Sonet"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.72 = STRING: "host__DtrCard_3.3V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.73 = STRING: "host__DtrCard_12V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.74 = STRING: "host__MB_Tcam3"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.75 = STRING: "host__MB_Tcam2"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.76 = STRING: "host__MB_Tcam1"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.77 = STRING: "host__MB_1.2Vsupply2"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.78 = STRING: "host__MB_1.2Vsupply1"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.79 = STRING: "host__MB_CPU_1.3V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.80 = STRING: "host__MB_PLL_1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.81 = STRING: "host__MB_0.75V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.82 = STRING: "host__MB_1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.83 = STRING: "host__MB_1.8V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.84 = STRING: "host__MB_1.25V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.85 = STRING: "host__MB_2.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.86 = STRING: "host__MB_3.3V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.87 = STRING: "host__MB_12V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.88 = STRING: "host__Mbus5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.89 = STRING: "host__InletTemp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.90 = STRING: "host__HotTemp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.105 = STRING: "spa0__3.3V_AUX"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.106 = STRING: "spa0__12V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.107 = STRING: "spa0__1.2V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.108 = STRING: "spa0__1.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.109 = STRING: "spa0__2.5V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.110 = STRING: "spa0__3.3V"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.111 = STRING: "spa0__DownStream_Temp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.112 = STRING: "spa0__UpStream_Temp"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.113 = STRING: "GE SX"
    SNMPv2-SMI::mib-2.47.1.1.1.1.2.114 = STRING: "GE SX"
    The "sh power status power-supply" isn't available, but I do have the following:
    #show env power-supply detail
                          48V       Current
    R/S/I     Module      (V)           (A)
    0/24/*    PEM1         52             8
              PEM2         52             8
        Total Power Supplies:                  2200W
            PEM  Description  Watts
            PEM1 Smart  AC    1100
            PEM2 Smart  AC    1100
        Redundant Power Supplies:              1100W
        Worst Case Power Used:                 1125W
         Slot Description                                        Max Watts
            0 Cisco 12000 Series Performance Route Processor            60
            1 Cisco 12000 Series - Multi-Service Blade                 250
            2 Cisco 12000 Series - Multi-Service Blade                 250
            3 Cisco 12000 Series SPA Interface Processor-              240
           17 GSR 12404 Consolidated Fabric/Alarm Card                 117
           24 Alarm Board(404)                                         208
        Worst Case Redundant Power Available:  None
        Worst Case Total Power Available:      1075W

  • RD640 power supply

    Does anyone know if the firmware referenced in this article has been released yet?
    http://support.lenovo.com/en/documents/ht100737?tabName=Solutionshttp://support.lenovo.com/en/docume...
    Thanks!
    Solved!
    Go to Solution.

    Hello,
    Yes, this firmware was released in November of 2014, however a newer version was released in December (version 20.00).  You can find it here.  This is the Windows Version of the update.  There are also BMC WebUI and DOS / Linux Options available.

  • Solution for monitor power supply and raid 5 on x4150 server

    Hi everybody,
    a simple question :
    my compagny have some server SunFire x4150 in some Datacenter, and there is a thing that we cannot really monitored remotly : the status of the 2 power supply and the status of the raid 5 of the server.
    (i want to know if a power is down or if a disk is "dead")
    We are using Nagios, cacti and munin actually, so can we use these interfaces for that?
    if the answer is no, a script can be developed , if only i knew the command that can be used to take informations from the state of the raid5, i'll comunicate later the type of the raid card.
    what are the best solutions availables for monitor those things?
    thanks by advance

    We have some x4150s but they're running Linux. There are separate solutions for each of the 2 problems.
    1. For the power supplies, you can use the ELOM/ILOM system management interface (also used for monitoring the fans and temperature). If you've got it configured and connected to the network, you can set it up to email you about any events. We have the older ELOM firmware running, which includes the ability to add some actions to take in response to specific events. The new and supposedly better ILOM firmware doesn't seem to include this. Since this is IPMI compatible you can probably also hook into this using ipmitool or SNMP tools.
    2. For the RAID card, assuming it's the standard Adaptec (rebranded as StorageTek) controller, you can install and use StorMan software (it's on the tools & drivers CD if not pre-installed). Once again you can configure email notification from the StorMan GUI, but this time it relies on OS host services to do the mail forwarding via the host NIC.
    I'm not familiar with the details of your network system admin tools, but hopefully these tips will provide pointers on what hooks are available for these tools to tie into. Presumably there's also Sun N1 management software which can probably do this in a more built-in way, but it sounds like you've already got more than enough management tools.

  • ISR 3945 second power supply...

    ... is plugged in, cable is connected to the power socket, and CLI output still shows:
    SYSTEM POWER SUPPLY STATUS
    ==========================
    Internal Power Supply 1 Type: AC
    Internal Power Supply 1 12V Output Status: Normal
    Internal Power Supply 2 Type: Unknown
    Internal Power Supply 2 Input Status and 12V Output Status: Fail
    I never dealth with physical aspects of Cisco devices before, and I`m not sure is there anything specific that needs to be done except plugging in the second PSU?

    Hi Milos im having the same problem than you, I have two C3945 and both of them presents the problem.
    The power supply is power on and connected in both sides of the cable (green led), but in CLI it shows fail status. It occurrs in the second power supply.
    Did you solved the problem? Could you help me please
    SYSTEM POWER SUPPLY STATUS
    ==========================
    Internal Power Supply 1 Type: AC
    Internal Power Supply 1 12V Output Status: Normal
    Internal Power Supply 2 Type: AC
    Internal Power Supply 2 12V Output Status: Fail
    Thanks in advance
    Regards

  • Use SNMP to monitor the power supply status of stacked switches

    Does anybody know how to use SNMP to monitor the status of the internal power supplies of a group of stacked Cisco 3750 switches?
    The switch stack has three 3750-48PS-E switches inter-connected by Cisco StackWise cable. IOS ver 12.1(19)EAlc. A single IP address is used to identify the switch stack. Every time I poll the OID chassisPs1Status (1.3.6.1.4.1.9.5.1.2.4.0 in CISCO-STACK-MIB), I only got the status for the Master switch of the switch stack. Is there any way to poll the power supply status of other switches in the switch stack?
    Thanks a lot!

    Sorry to refresh such an old topic - but I am stuck with exactly this: Monitoring power supplies of a stacked Cisco Catalyst 3750-E.
    I'm using the exact same OID's as described, but the problem is, the information shown on the SNMP output is not correct.
    This morning, a power supply of the first switch failed and switched to RPS. Here the information I got on SNMP:
    snmpwalk -v 2c -c public 192.168.1.50 1.3.6.1.4.1.9.9.13.1
    SNMPv2-SMI::enterprises.9.9.13.1.1.0 = INTEGER: 13
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.2.1006 = STRING: "SW#1, Sensor#1, GREEN "
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.2.2006 = STRING: "SW#2, Sensor#1, GREEN "
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.1006 = Gauge32: 41
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.2006 = Gauge32: 40
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.4.1006 = INTEGER: 59
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.4.2006 = INTEGER: 59
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.5.1006 = INTEGER: 0
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.5.2006 = INTEGER: 0
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.6.1006 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.3.1.6.2006 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.4.1.2.1060 = STRING: "Switch#1, Fan#1"
    SNMPv2-SMI::enterprises.9.9.13.1.4.1.2.2059 = STRING: "Switch#2, Fan#1"
    SNMPv2-SMI::enterprises.9.9.13.1.4.1.3.1060 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.4.1.3.2059 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.2.1059 = STRING: "Sw1, PS1 Normal, RPS NotExist"
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.2.2060 = STRING: "Sw2, PS1 Normal, RPS NotExist"
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.3.1059 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.3.2060 = INTEGER: 1
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.4.1059 = INTEGER: 2
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.4.2060 = INTEGER: 2
    As you see, both PS1 (for both switches) are appearing normal. It doesn't even recognize RPS:
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.2.1059 = STRING: "Sw1, PS1 Normal, RPS NotExist"
    SNMPv2-SMI::enterprises.9.9.13.1.5.1.2.2060 = STRING: "Sw2, PS1 Normal, RPS NotExist"
    The first switch's power supply died and now the cable is disconnected. LED's of the power supply are out. And still: The switch happily announces by SNMP it's power supplies are up.
    Is this a known bug? If yes, has it been fixed?
    Model  WS-C3750E-48TD
    Firmware 12.2(37)SE1
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
    mso-para-margin:0cm;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;
    mso-bidi-font-family:"Times New Roman";
    mso-bidi-theme-font:minor-bidi;}

  • ASA 5512 - monitor power supply status via snmp oid

    Device – ASA 5512 running 9.1(1).
    Show version:
    ASA-1# sh ver
    Cisco Adaptive Security Appliance Software Version 9.1(1)
    Device Manager Version 6.6(1)
    Compiled on Wed 28-Nov-12 11:15 PST by builders
    System image file is "disk0:/asa911-smp-k8.bin"
    Config file at boot was "startup-config"
    ASA-1 up 8 hours 38 mins
    Hardware:   ASA5512-K7, 4096 MB RAM, CPU Clarkdale 2792 MHz, 1 CPU (2 cores)
                ASA: 2048 MB RAM, 1 CPU (1 core)
    Internal ATA Compact Flash, 4096MB
    BIOS Flash MX25L6445E @ 0xffbb0000, 8192KB
    Issue: looking for a snmp OID to poll power supply status (Inbuilt Power Supply -  no redundant power supply in this scenario). Possibly what we see in show environment.
    CSE analysis:
    I tried using the OIDs belonging to CISCO-ENTITY-FRU-CONTROL-MIB , like cefcFRUPowerOperStatus and cefcFRUPowerAdminStatus but it didn’t return anything.
    NOTE: I have done all the snmp walks from the Linux server. Do I doubt it’s something to do from the snmp manager side.
    Couple of observations. The  CISCO-ENTITY-FRU-CONTROL-MIB talks about the field replaceable power supplies, so I doubt if it’s going to return the value for inbuilt power supply.
    Second, I noticed that there are snmp traps supported for power supply and threshold setting. See configuration below. Is it that only traps works for power supply and environment related details?
    Snmpwalk on cefcFRUPowerStatusEntry returns nothing:
    [root@tonbenso-eagle bin]# ./snmpwalk -v2c -c public 172.16.169.29 1.3.6.1.4.1.9.9.117.1.1.2.1
    SNMPv2-SMI::enterprises.9.9.117.1.1.2.1 = No Such Object available on this agent at this OID
    Snmpwalk on cefcFRUPowerOperStatus returns nothing:
    [root@tonbenso-eagle bin]# ./snmpwalk -v2c -c public 172.16.169.29 1.3.6.1.4.1.9.9.117.1.1.2.1.2
    SNMPv2-SMI::enterprises.9.9.117.1.1.2.1.2 = No Such Instance currently exists at this OID
    Snmpwalk on cefcFRUPowerAdminStatus returns nothing:
    [root@tonbenso-eagle bin]# ./snmpwalk -v2c -c public 172.16.169.29 1.3.6.1.4.1.9.9.117.1.1.2.1.1
    SNMPv2-SMI::enterprises.9.9.117.1.1.2.1.1 = No Such Instance currently exists at this OID
    [root@tonbenso-eagle bin]#
    login as: root
    I tried polling the ciscoEntityFRUControlMIB to see what all values it return. It just returned enterprises.9.9.117.1.3.1.0 = INTEGER: 2. Meaning cefcMIBEnableStatusNotification is FALSE (value 2). Meaning cefcModuleStatusChange, cefcPowerStatusChange, cefcFRUInserted, cefcFRURemoved, cefcUnrecognizedFRU and cefcFanTrayStatusChange are prevented from being sent.
    Snmpwalk on ciscoEntityFRUControlMIB
    [1]+  Stopped                 ./snmpwalk -v2c -c public 172.16.169.29
    [root@tonbenso-eagle bin]# ./snmpwalk -v2c -c public 172.16.169.29 1.3.6.1.4.1.9.9.117
    SNMPv2-SMI::enterprises.9.9.117.1.3.1.0 = INTEGER: 2
    Object
    cefcMIBEnableStatusNotification
    OID
    1.3.6.1.4.1.9.9.117.1.3.1
    Type
    TruthValue
    Permission
    read-write
    Status
    current
    MIB
    CISCO-ENTITY-FRU-CONTROL-MIB ;   -   View Supporting Images
    Description
    "This variable indicates whether the system
    produces the following notifications:
    cefcModuleStatusChange, cefcPowerStatusChange,
    cefcFRUInserted, cefcFRURemoved,
    cefcUnrecognizedFRU and cefcFanTrayStatusChange.
    A false value will prevent these notifications
    from being generated."
    Found couple of bugs:
    CSCty32558 – but then this is for 5585 and I see it is fixed in 8.4
    CSCul90037 – New state
    Show snmp-server oidlist:
    http://www-tac.cisco.com/Teams/ks/c3/getLargeFile.php?srId=632222409&fileName=20141030-013905_ASA-show-snmp-server-oidlist.txt
    Show tech:
    Sh run | in snmp:
    ASA-1# sh run | in snmp
    snmp-server host asa 172.18.123.228 community *****
    no snmp-server location
    no snmp-server contact
    snmp-server community *****
    snmp-server enable traps entity power-supply-presence power-supply-temperature  -----à I was talking about this trap above
    any help will be appreciated.

    Hi
    I've got an ASA with redundant power supplies. An ASA5585. So I have the need to monitor them. :-) So how can we do it?
    Also I've made a SNMP-Walk through the ASA v8.4(2)8 and it doesn't show up any ENV-MIB values. The
    1.3.6.1.4.1.9.9.13 tree is not available. Are you shure it's available on the ASA?
    Funny is also that the command "show snmp-server oidlist" from the 8.4 configuration guide is not available on the real CLI. I think the documentation guys were faster than the coders. ;-)
    Kind regards
    Roberto

  • Monitoring 3750x and 3560x Redundant Power Supply and Fans

    I need help for monitoring the redundant power supply of my switches (3750x and 3560x)
    I have configured my snmp on my switches and is able to monitor interfaces, temperature and etc.
    The problem is when I am monitoring the redundant power supply and fans.
    I am using two Cisco C3KX-PWR-350WAC Modular Power Supply per switch.
    The OID I use to monitor the PSU are the following:
    Power Supply 1
    .1.3.6.1.4.1.9.9.13.1.5.1.3 Instance: 1003
    Power Supply 2
    .1.3.6.1.4.1.9.9.13.1.5.1.3 Instance: 1004
    When I do an SNMP walk, the value is showing (1) which means normal.
    When I simulate a power outage on power supply 1 or 2 by unplugging the power source, the value doesn't change and is still (1).
    Values: normal(1), warning(2), critical(3), shutdown(4), notPresent(5)
    As for the Fans:
    When I remove the fan module, I am able to get a notification that the fans are down, but when I plug back the fan module it is now using a different instance.
    Below is my config for SNMP:
    snmp-server community XXXXXXXXXXXXXX RO
    snmp-server location XXXXXX
    snmp-server contact XXXXXX
    snmp-server chassis-id Cisco3560X
    snmp-server enable traps snmp authentication linkdown linkup coldstart warmstart
    snmp-server enable traps transceiver all
    snmp-server enable traps tty
    snmp-server enable traps license
    snmp-server enable traps cpu threshold
    snmp-server enable traps syslog
    snmp-server enable traps vlancreate
    snmp-server enable traps vlandelete
    snmp-server enable traps port-security
    snmp-server enable traps envmon fan shutdown supply temperature status
    snmp-server enable traps errdisable
    snmp-server enable traps vlan-membership
    snmp-server host X.X.X.X version 2c XXXXXXXXXXXXXX
    Note: This problem is the same for all of my 3560X switches and 3750X switches. I am not sure if I am monitoring the wrong OID. 
    Thanks in advance

    Hi ,
    You are running an old IOS code , definitely you are hitting a BUG .
    there is no workaround or I would say unfirtunetely you will not be able to get the correct power supply status via SNMP.
    you need to use command line for this.
    I mean "show env all "
    **** if you want to know the Excat BUG that your code is hitting ,please contact TAC.
    Thanks-
    Afroz
    **Ratings Encourages Contributors ****

  • Power Supply Status Changed - every 12 seconds

    Server Monitor shows all green for all components, but the log shows a red message every 12 seconds "Power Supply Status Changed". The power is coming through an APC UPS device, which also appears to be working fine. Any ideas?
    Xserve G5 Dual   Mac OS X (10.4.5)  

    Last night I got an Email:
    Subject: Server Problem Notification
    A problem has been detected on this server.
    ============================================================
    Status Summary
    Reason(s) for notification:
    Power
    Server:
    Host : geekho
    Model : RackMac3,1
    Uptime : 17952 minutes
    OS version : Mac OS X Server 10.4.6 (8I127)
    Processor : 1 x 2000 MHz
    Memory : 2048 MB
    BootROM : $0005.17f2
    Serial : QP6170FQSLX
    Memory:
    Memory Slot "DIMM0/J11" : 1024MB, ECC DDR SDRAM, PC3200U-30330
    Memory Slot "DIMM1/J12" : 1024MB, ECC DDR SDRAM, PC3200U-30330
    Drives:
    Drive 1 (disk0) : Normal
    Drive 2 (disk1) : Normal
    Network:
    en0 ( active) : Normal
    Sensors:
    CPU 1 Power : 12.55 watts
    1.5v : 1.49 volts
    3.3v Trickle : 3.30 volts
    5v : 5.04 volts
    12v Trickle : 12.06 volts
    1.2v : 1.18 volts
    Behind the DIMMs : 52.00 C
    1.8v : 1.80 volts
    System Bus IO VDD : 1.46 volts
    PCI Slots : 45.00 C
    DDR IO : 2.63 volts
    DDR IO Sleep : 2.63 volts
    3.3v : 3.30 volts
    3.3v Sleep : 3.28 volts
    5v Sleep : 5.07 volts
    12v : 12.00 volts
    System Controller Vcore : 1.71 volts
    1.5v Sleep : 1.51 volts
    1.2v Sleep : 1.18 volts
    Between the Processors : 34.00 C
    CPU 1 Internal : 46.02 C
    CPU 1 12v : 0.94 amps
    CPU 1 Vcore : 1.27 volts
    CPU 1 Core : 9.89 amps
    System Controller Internal : 55.75 C
    CPU 1 Ambient : 38.00 C
    System Controller Ambient : 44.00 C
    CPU 1 Inlet : 30.00 C
    CPU 2 Inlet : 27.50 C
    Controls:
    CPU A1 : 3973 RPMs
    CPU A2 : 3988 RPMs
    CPU A3 : 4002 RPMs
    CPU B1 : 3992 RPMs
    CPU B2 : 4017 RPMs
    CPU B3 : 3982 RPMs
    System Controller : 5585 RPMs
    PCI Slot : 3890 RPMs
    Clock Slew :
    Security:
    Enclosure Intrusion : No
    ============================================================
    I don't see anything wrong (CPU power?), and the Server Monitor app shows all green lights and everything "Normal" except CPU Core amps at 7 amps peaking to 10.25 or so, which it calls "High".
    What (if anything) is wrong, and what (if anything) should/could I do to fix it? Is this related to the original problem?
    Thanks!

  • HP vs15 monitor audio power supply voltage and amps

    I have a HP vs15 monitor that I need to know the audio power supply voltage and amperage.

    HI grizspeck:
    Thank you for your inquiry.
    I am sending you a link to the specifications of he HP Pavilion vs15 monitor  click here.
    Sparkles1
    I work on behalf of HP
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    Click the “Kudos, Thumbs Up" on the bottom right to say “Thanks” for helping!

  • I need a monitor power supply for HP2711X. Where can I buy one?

    I need a monitor power supply for HP2711X. Where can I buy one?
    This question was solved.
    View Solution.

    Because the XP597A3 (actually any of these product numbers; XP597AA, XP597A3, XP597AS) is a HP 2011x 20" LCD/LED widescreen monitor. The OP was looking for an A/C adapter power supply for the HP 2711x 27" LCD/LED widescreen monitor, which is product # XP600AA or XP600A3. The adapter power supply I linked to, is the correct part for the 2711x monitor.... that is why not those other parts.
    Frank
    {------------ Please click the "White Kudos" Thumbs Up to say THANKS for helping.
    Please click the "Accept As Solution" on my post, if my assistance has solved your issue. ------------V
    This is a user supported forum. I am a volunteer and I don't work for HP.
    HP 15t-j100 (on loan from HP)
    HP 13 Split x2 (on loan from HP)
    HP Slate8 Pro (on loan from HP)
    HP a1632x - Windows 7, 4GB RAM, AMD Radeon HD 6450
    HP p6130y - Windows 7, 8GB RAM, AMD Radeon HD 6450
    HP p6320y - Windows 7, 8GB RAM, NVIDIA GT 240
    HP p7-1026 - Windows 7, 6GB RAM, AMD Radeon HD 6450
    HP p6787c - Windows 7, 8GB RAM, NVIDIA GT 240

  • How to check Temp/Power supply status like V210 in T2000

    Hi
    As I would like to know what is the command to check the Power Supply Status/Temp Status like V210 in T2000. I tried with /usr/platform/sun4v/sbin/prtdiag –v command like V210 but it disaplys only below details.
    System Configuration: Sun Microsystems sun4v Sun Fire T200
    System clock frequency: 200 MHz
    Memory size: 8184 Megabytes
    ================================ Virtual CPUs ================================
    CPU ID Frequency Implementation Status
    0 1000 MHz SUNW,UltraSPARC-T1 on-line
    1 1000 MHz SUNW,UltraSPARC-T1 on-line
    2 1000 MHz SUNW,UltraSPARC-T1 on-line
    3 1000 MHz SUNW,UltraSPARC-T1 on-line
    4 1000 MHz SUNW,UltraSPARC-T1 on-line
    5 1000 MHz SUNW,UltraSPARC-T1 on-line
    6 1000 MHz SUNW,UltraSPARC-T1 on-line
    7 1000 MHz SUNW,UltraSPARC-T1 on-line
    8 1000 MHz SUNW,UltraSPARC-T1 on-line
    9 1000 MHz SUNW,UltraSPARC-T1 on-line
    10 1000 MHz SUNW,UltraSPARC-T1 on-line
    11 1000 MHz SUNW,UltraSPARC-T1 on-line
    12 1000 MHz SUNW,UltraSPARC-T1 on-line
    13 1000 MHz SUNW,UltraSPARC-T1 on-line
    14 1000 MHz SUNW,UltraSPARC-T1 on-line
    15 1000 MHz SUNW,UltraSPARC-T1 on-line
    ========================= IO Configuration =========================
    IO
    Location Type Slot Path Name Model
    IOBD/NET0 PCIE IOBD /pci@780/pci@0/pci@1/network@0 network-pciex8086,105e
    IOBD/NET1 PCIE IOBD /pci@780/pci@0/pci@1/network@0,1 network-pciex8086,105e
    IOBD/PCIE PCIE IOBD /pci@780/pci@0/pci@9/scsi@0 scsi-pciex1000,56 LSI,1064E
    IOBD/NET2 PCIE IOBD /pci@7c0/pci@0/pci@2/network@0 network-pciex8086,105e
    IOBD/NET3 PCIE IOBD /pci@7c0/pci@0/pci@2/network@0,1 network-pciex8086,105e
    IOBD/PCIE1 PCIE 1 /pci@7c0/pci@0/pci@8/network@0 network-pciex108e,abcd SUNW,pcie+
    IOBD/PCIE1 PCIE 1 /pci@7c0/pci@0/pci@8/network@0,1 network-pciex108e,abcd SUNW,pcie+
    IOBD/PCIE1 PCIE 1 /pci@7c0/pci@0/pci@8/network@0,2 network-pciex108e,abcd SUNW,pcie+
    IOBD/PCIE1 PCIE 1 /pci@7c0/pci@0/pci@8/network@0,3 network-pciex108e,abcd SUNW,pcie+
    IOBD/PCIX PCIX IOBD /pci@7c0/pci@0/pci@1/pci@0/isa@2 isa
    IOBD/PCIX PCIX IOBD /pci@7c0/pci@0/pci@1/pci@0/usb@5 usb-pciclass,0c0310
    IOBD/PCIX PCIX IOBD /pci@7c0/pci@0/pci@1/pci@0/usb@6 usb-pciclass,0c0310
    IOBD/PCIX PCIX IOBD /pci@7c0/pci@0/pci@1/pci@0/ide@8 ide-pci10b9,5229
    ========================= HW Revisions =======================================
    System PROM revisions:
    OBP 4.25.12 2008/03/23 13:27
    IO ASIC revisions:
    Location Path Device Revision
    IOBD/SAS-SATA-HBA /pci@780 SUNW,sun4v-pci 0
    IOBD/SAS-SATA-HBA /pci@780/pci@0 pciex10b5,8532.bc 188
    IOBD/SAS-SATA-HBA /pci@780/pci@0/pci@9 pciex10b5,8532.bc 188
    IOBD/IO-BRIDGE /pci@7c0 SUNW,sun4v-pci 0
    IOBD/PCI-SWITCH1 /pci@7c0/pci@0 pciex10b5,8532.bc 188
    IOBD/PCI-BRIDGE /pci@7c0/pci@0/pci@1/pci@0,2 pciex8086,341.9 9
    IOBD/GBE0 /pci@780/pci@0/pci@1/network@0 pciex8086,105e.108e.105e.6 6
    IOBD/GBE0 /pci@780/pci@0/pci@1/network@0,1 pciex8086,105e.108e.105e.6 6
    IOBD/GBE1 /pci@7c0/pci@0/pci@2/network@0 pciex8086,105e.108e.105e.6 6
    IOBD/GBE1 /pci@7c0/pci@0/pci@2/network@0,1 pciex8086,105e.108e.105e.6 6
    IOBD/SAS-SATA-HBA /pci@780/pci@0/pci@9/scsi@0 pciex1000,56.1000.1000.2 2
    I am interested in getting the same o/p which also gives status on Fan Status/Power Supplies etc.
    Please let me know do we need to upgrdae the OBP Version else ?
    Thanks
    Rajan

    Hi
    In thee same ref. I would like to know the comand from OS/Bash prompt so that I can write the script in which it will compare the values and alert me accordingly.
    In case sc> prompt there is commnand "show environment" which give all details.
    Thanks
    Rajan

  • Display the power supply status in the IPS 4270

    How to display the status of the power supply on the IPS 4270
    since the IPS has two power supplies and one has failed, so i want to check what is causing this failure (i am looking for a message from the CLI describing that the IPS power were failed).

    At this time, there is no method to display the status of the power supply from the CLI or IDM GUI of the IPS-4270.  There is an open enhancement request to have this capability added in a future release of the IPS software.
    Scott

  • Power Supply Status Changed

    A while back our Xserve G5 went on UPS power for a few seconds. No big deal just a power blip.
    Since then we get a "Power Supply Status Changed" message in the server log ever 12 seconds. I can't get it to go away. Server has been rebooted multiple times.
    The OS Version is 10.4.1
    Everything is functioning normally and there are no power problems. How do I stop this message?

    We are also using the APC. Not sure which model, but we are also getting the same messages. We disconnected the cable early last week and the message is still going. We have been investigating all logs on our server for another problem which is where the server just stops being available on the network. To fix requires a restart using the power button to turn if off and then on again.
    Then all is normal except for the "Power Supply Status Changed" error.
    So far this is the only error we get that shows a problem exists.
    Is anyone else also having the lockup problem?
    X Serve G5   Mac OS X (10.4.3)   RAID

  • X99S Gaming 9 ACK - power supply compatibility - JPWR2 and JPWR3- Status code 00

    Hello,
    Setting up a newly purchased X99S Gaming 9 ACK, and would appreciate any help.  Can't get past status code 00 and am in debug mode.
    First step in my debug process, I'm trying to confirm power supply requirements.   The board has two 12V input connectors - JPWR2 and JPWR3.  The manual mentions them both.  However, my power supply only has one 12V "EPS12V" cable with an 8 pin connector that can be separated into 4+4. 
    A quick search did not turn up any power supplies that come stock with two 12V cables.  This seemed odd, so I searched for information for JPWR2 and JPWR3 hoping to find something and what turned up was somewhat contradictory.  Some info out there seems to suggest that powering one of the two would be OK if not overclocking.  So I tried that - first just JPWR3, then split the power connector and did just JPWR2, then did JPWR2 and part of JPWR3....and then just to confirm what I thought I was seeing (that 00 status is telling me the CPU's not active) I removed everything from both JPWR2 and JPWR3.  In all cases, the status code was 00.
    So I'm looking to find out how folks with this MB actually working have connected the power.
    Question 1:  Does anyone run it without having both JPWR2 and JPWR3 connected?  If so, what approach do you use?
    Question 2:  Does anyone run it having them both connected?  If so, please let me know what power supply you use.  I am guessing maybe a configurable cable sort could be set up with two 12V lines?
    I know, it's possible with no known-good components (well, the power supply is freshly removed from a happily functioning PC, so it's not suspect) I may have either a bad CPU or a bad MB.  And they are both brand new and eminently returnable.  But I don't want to do that till I know I've got them powered correctly.  I'm relatively confident (well, hopeful) that having the correct power supply setup will let me get past 00 status code and see what else I get to debug.
    Thanks in advance for any and all help.

    Thanks for the input.  Reset CMOS, removed all but the first stick of RAM.  No change.  Status code 00.
    Initial PS was the Corsair TX750W.  I got another power supply to test that has cables to fill both JPWR2 and JPWR3.  No change.  Status code 00.
    So, apparently a DOA Motherboard.  Was afraid of that.  Sending it back to try again.

Maybe you are looking for

  • BAPI for outbound delivery without order reference - VL01NO

    Hi , I need a BAPI to create a outbound delivery without a Order reference ( transaction VL01NO ). Please provide the BAPI. Sample code will be helpful. Thanks, R~

  • Using my iPhone 4s (AT&T) in London

    Traveling to London soon and curious if I can simpy purchase a pre-paid sim card in London and use it inside my iPhone 4s. Is this the best bet? Surely this is cheaper than subscribing to one of AT&T international plans. Thanks for your help! *Side q

  • ME21N

    Dear All, Can I check the price, quantity in last three purchase orders for a particular material at the time of PO creation. My client requires the information in the same screen of PO creation, not in any other T-code. Regards Prabhjot Singh

  • Where can I file bug reports?

    Hi all, Just got back from Day 3 of the Toronto Code Manuvers (Kick ass show). I've been playing with Creator 2 early access and have found many bugs that I want to check on/report on. Can someone please tell me where I can get/set bugs? Cheers

  • Command to delete Doubles

    Is there a quick way to delete double, triple even quadriple copies of songs in my music library?