Re:why unit of measure is changed in miro

Hi guru's,
My user has made a P.O. migo & miro, for the required material
P.O. unit is box
GR   unit is box
I.V    unit is changed to Pcs.
the alternate unit of measure maintained for the said material is Pcs & Box.
Can anybody advise me what to do to get the same unit as P.O. & Migo.
thanks
tuljasingh.

Order unit is the unit in which the material will be ordered to procure.
An alternative unit of measure that can be used for ordering purposes.
The purchase order price unit enables you to express the purchase order price in a unit that differs from the order unit.
Example
Ordered: 100 m2;    Price: $24.20 for 10 kg.
The order unit is m2. The purchase order price unit is kg.
regards,
indranil

Similar Messages

  • Why will my units of measure not change

    I have an old ai file created in CS5 and am opening in CS6 is comes in with cm even though I have changed the units of measure with the file open and also with no files open. Yet every time I open the file it is still in cm. Any ideas?

    Hi Jacob,
    Tried that already no go. Have tried changing with no documents open, with documents open saved as CS6. All my other files seem fine but this one will not update.
    Thanks
    Emma
    On 2014-07-10, at 11:02 AM, Jacob Bugge <[email protected]<mailto:[email protected]>>

  • SAPscript unit of measurement (UoM) changed during print

    Hi Experts,
    I am doing my SAPscript and its print program for Invoice printing (VF02/VF03). The problem only occurs when its UoM is BOX. It will display in the Invoice printing as '012' instead of BOX. When I debug in the print program, in structure VBDPR (field VRKME), it has the correct UoM which is BOX. When I debug my SAPscript, it will give me 012 as its UoM!! I don't know what is the reason behind this behavior. Please advice.
    Points will be given....Thanks in advance.
    Regards,
    Fauzah.

    hi
    For all other UoM is it coming correct ?
      there is two table fields for UoM MEINS n GEWEI , check which one ur displaying in Sap Script.
        try with do change in that field , thic can solve ur problam .

  • Extrude Depth Unit of Measurement: Can you change it?

    When using the Bevel and Extrude function in Illustrator, can the unit of measurement be changed to inches instead of points?
    Doesnt appear to be possible.

    You can type "in" after the number and AI will convert inches to points.

  • Material Master Unit Of Measurement Changes Clarification

    Hi
    We have a material master with base unit of measurement as FT in basic data 1 view.
    For this we have already some purchsing documents like PO's and PR's
    But currently we dont have any open PO (or) PR and stock in system.
    Still we could not change the base unit of measurement from FT to M..
    Why?
    Vijay

    Hello All,
    The error shows some of PR's and PO's numbers.
    when i check the material in table MBEWH i can see some of the stocks for previous period like year 2009 and the period 06 and some of the previous year like 2008 and 2007 also having some stocks.
    Now advise.
    Vijay

  • Change for Unit of measure in condition master

    Hi, gurus..
    I want to know this is SAP error or not..
    I created condition for material H20.
    H20     70500 usd  per 1 SET
    and edited the unit of measure in addtion of material master record.
    1 EA - 1EA
    1 SET - 6 EA
    then I create SO in VA01 with line item
    H20   1EA   ...
    but condition record showed me a wrong value..
    H20    11774  usd  per 1EA...
    70500 / 6  = 11750  usd..Why  11774...??
    So, I changed the condition for more test..
    H20  11750 usd per 1EA...
    After input line item in VA01.
    H20  1 Set...
    then condition was 70500 usd per 1 SET ..Right result..
    I tried it on other system ( Best Practices 1606) once more  but result was same.
    This is SAP ERROR ??? or not..
    Plz..give me your ideas..

    Dear Kim,
    this error will come due to conversion factor at sales order level .kindly check in the item level how the conversion factor will take the system and also try to change the Quantity and check once again. this will come rare case , if you want to check the conversion error ,debug at the sales order level . for your reference I am attachment the conversion factor path .
    Regards,

  • While making changes in alternate Unit of measure CAR it makes changes

    While making changes in alternate Unit of measure CAR it makes changes in other alternate Unit of measure KAR.
    Both are having same ISO unit CT.Please suggest why it is happening.

    your units have probably a conversion rate to the SI unit in its definition.
    you can see this in CUNI, open your unit in detail and look at the lower left  part

  • Unit of Measure issue - Need to be changed from volume to no dimention.

    Hi Experts,
               I have a unit of measure as TB, which is tube. This is a volume unit. The user want to change this as "Pls have this be corrected as a non-dimensional unit of measure ". For this what is impact on system.
              Precautions to be taken to change this unit of measure. what are all we have to do. like closing all open POs, PR, RFQ,SO , production order, planned orders etc.
              And what about the stocks for these materials which are using these UOM.
              Please suggest me, what are all we have to do, before going for a change.
    Thanks & Regards,
    Poorna.

    Dear,
    The base unit of measurement for a material cannot be changed due to movements history exists. This will result to inconsistency in reports and data.
    Suggested to create similar new material with new user desired UOM.
    Please find the SAP HELP on this as below:
    Diagnosis:  You wanted to change the base unit of measure. However, you can do so only under certain circumstances, including the following:
    - If there are no stocks of the material in the current period and in the previous period.
    - If there are stocks in the previous period, you can clear them as follows:
    a) Post the stock in the previous period to the current period (for example, using movement type 561 Posting date 30.06.XX ) so that the stock for the previous period is the same as the stock for the current period.
    b) Clear the stock with the posting date in the previous period (for example, using movement type 562 Posting date 30.05.XX).
    - If no purchase requisitions, purchase orders, or scheduling agreements exist for the material.
    Procedure :  Choose Display errors to see why you cannot change the base unit of measure for this material.
    The pushbutton Display errors appears only in dialog mode, not in data transfer or in mass maintenance. If this message appears in data transfer or in mass maintenance, and you want to know why the base unit of measure cannot be changed, access the material in dialog mode using the relevant transaction below, try to change the base unit of measure as required, and then choose Display errors:
    Lastly, you can considered an Alternate Unit of Measure to do the Conversion from KG to Liter. You then could use your Alternate Unit of Measure as your 
    Purchased UoM and PLant UoM.
    Given the level of activity sometimes required to change the base UOM, it often makes more sense just to add an alternative UOM on the material master. 
    Maintain the relationship between the Base UOM and the new UOM on the material master and then continue to procure the material in the new UOM rather than the base UOM. If stocks exist I would think it is unlikely that their existing UOM is incorrect as they must have been receipted in that UOM at some point.
    Regards,
    Syed Hussain.

  • Why do units of measurement in paragraph tab and character tab differ?

    Why do units of measurement in paragraph tab and character tab differ?
    In Indesign CC 2014.1 when I set the units for type to be in points and all other measurements apart from strokes to be in mm, why are the units for the paragraph tab also in mm?
    In both Photoshop CC and Illustrator CC, whatever units you assign for type also are used for the paragraph settings, which makes sense.
    I want everything to do with type to be in points and pretty much everything else in mm, yet the only way I can have the paragraph tab units as points is for all measurements to be in points!
    Does this sound right or is something wrong with my Indesign?
    Thanks
    Keith

    Glu Design wrote:
    Ok guys I see. I just wondered why InDesign differed to both Photoshop and Illustrator in this respect.
    Thanks
    Keith
    They are made by Adobe, and Adobe has different teams for different applications.
    Sometimes the same feature in multiple applications is designed slightly differently than the way other teams would handle it.
    This may be down to:
    Time constraints to get the feature in - compared to other top priority items
    Having to make a decision on whether to do it one way or another way - 50/50 type thing
    Due to the limitations of how the program was designed and how the feature ties in with other features etc.
    And many many more programming reasons. It may be the guy doing the photoshop changes wasn't as well versed in typography needs as the indesign guy.
    Who knows - but there are differences in lots of areas between all apps.

  • To Change Basic Unit of Measure

    Dear Sappers,
    With refernce to my previous posted thread, below  I am giving the detailed copy of *PERFORMANCE ASSISTANCE*
    The Performance Assistance is giving me solution to proceed but for proceeding further is not possible. As max no of sessions are 2.
    Also massege is generated by MM02 & solution given is also same MM02.
    Please find below pasted Performance assistance.
    The base unit of measure cannot be changed; choose "Display errors"
    Message no. M3189
    Diagnosis
    You wanted to change the base unit of measure. However, you can do so only under certain circumstances, including the following:
    If there are no stocks of the material in the current period and in the previous period
    If there are stocks in the previous period, you can clear them as follows:
    a) Post the stock in the previous period to the current period (for example, using movement type 561) so that the stock for the previous period is the same as the stock for the current period.
    b) Clear the stock with the posting date in the previous period (for example, using movement type 562).
    If no purchase requisitions, purchase orders, or scheduling agreements exist for the material
    Procedure
    Choose Display errors to see why you cannot change the base unit of measure for this material.
    The pushbutton Display errors appears only in dialog mode, not in data transfer or in mass maintenance. If this message appears in data transfer or in mass maintenance, and you want to know why the base unit of measure cannot be changed, access the material in dialog mode using the relevant transaction below, try to change the base unit of measure as required, and then choose Display errors:
    Industry
    Proceed
    Retail
    Proceed

    Dear Friend,
    Please do the following:
    1. MM02 + material number, select basic view 1
    2. Change the BUoM + press enter
    3. A button called 'Display error' will appear between the description of the transaction and 'basic view 1' tab. ( left from 'Additional data' button ) > please click on it
    4. Examine the message
    If you have question please come back!
    BR
    Csaba

  • T006-Decan change after users have used the TO unit of measure

    Currently in our system for TO (tonnes) it has T006-Andec as 3 and T006-Decan as 0 and it issues the users a warning message "Order quantity violates rounding rule" if they type in decimals in the purchase order quantity.  We have been asked to change T006-Decan to a 3 and do away with the warning message.  What happens if you change T006-Decan from 0 to 3 after users have already used the unit of measure (TO) in the R/3 SAP_APPL 470 system on materials, purchase orders, sales documents, receipts, etc...?  I don't want to impact our users in production since I do not where this unit of measure has been used.  Any advice is welcomed.  Thank you.

    Hi
    If you are changing the decimal places in T006 - DECAN , the number which was 1000 would show as 1,000... so previously it was 1000 tonnes now it will show as 1 tonne.... such things happen....Check with SAP before doing changes to the Standard UOM's...
    I am not able to find the correct SAP note for this.... but its there hope you get it
    Thanks & Regards
    Kishore

  • In RG1 ,Unit of measurement is KG,User want to change as MR

    Hi Experts,
    In RG1,user want to change unit of measurement as KG to MR.Now its showing KG but in billing there is unit of measurement is MR .I have checked material master.I found following:
    base unit of measurement is KG
    sales Unit: SM
    while creating order system default unit of measurement showing SM.In Additional data there are some conversion factors.
    Please help me gurus
    how can i covert KG to MR in RG1? as in billing it is MR.
    Thanks & Regards,
    Ravindra

    Hi Ram,
    Thanks for the reply.
    Problem coming in RG1 as UOM comming  KG.user already billed in MR as there is conversion factor in material master MR to KG.
    According to your suggetion if i changed sales unit as MR it comes defaulted in order then in invoice.but in RG1 still it showing KG as UOM.
    Can you explain about RG1? In RG1 may be system catch only base unit of measurement which is KG.
    Thanks & Regards,
    Ravindra

  • How can i change unit of measurement in sales order on header

    Dear all,
    I have material master with base unit of measurement " Ea ".
    I have to take unit Pc in sales order.
    how can i change unit on header in sales order.
    i changed unit on line item in sales order by setting in sales unit field in material master.

    Hi,
    You can very well do it, please do the following steps,
    Go to material master and select the Sales Org.1 and 2, here maintain the sales unit PC and
    it will ask you for the conversion, so maintain your conversion for PC to EA. Then maintain
    the Division, delivery plant, material pricing group and account assignment group(if not maintained) and save it
    Now create the sales order for that resp. material, you will find that system will pick up
    the sales unit which is maintained in the material master's sales orgnization tab.
    For this you need not to change at the header level of sales order
    Please check and revert.
    Thanks,
    Hrishi

  • Changing Base Unit Of Measure in Material Master

    Dear All,
                  We need to change the base unit of measure of certain materials who have been assigned inspection plan. We have deleted the material from Inspection Plan and later even the plan. But still the system not allowing to change the BASE UNIT OF MEASURE. The error thrown by the system is : Material is assigned to inspection Plan.
    Please guide in this regard as changing the material for us will be a very cumbersome act.
    Regards

    Hi Rohan,
    Please check 'display errors' in MM02 when you are trying to change the BUoM. It will say what prevents you from doing that.
    Please check:
    http://www.sap-img.com/materials/change-base-unit-of-measure.htm
    BR
    Csaba

  • Met problem to change unit of measure in material master

    Our prime made mistake when creating material master with MM01. He used wrong unit of measure EA instead of right one M. And when he recognized this issue and tried to change it with MM02 in view Basic1, system prompt him an error message that "Standard cost estimates for the current period already exist".
    So, please help to let me know how can I delete related records about cost estimates and avoid this error. Thanks a lot.

    Robbie,
    You can delete Cost estimates using T-code:  CKR1 , I am not sure if you can change UoM if you have any goods movements  on the material. The best option would be create new material with correct UoM and transfer stock from old Material to New one with proper Conversion.
    Thanks
    Sivaram

Maybe you are looking for

  • Currency type in COPA report

    I created a form to generate a COPA report.  I selected "both company code and operating concern currency types while creating the form.  Now, I need to be able to give the currency type as variable to have the user print the copa report whatever cur

  • How to improve the execution time of my VI?

    My vi does data processing for hundreds of files and takes more than 20 minutes to commplete. The setup is firstly i use the directory LIST function to list all the files in a dir. to a string array. Then I index this string array into a for loop, in

  • Internet radio no longer works on E1000 network

    My E1000 no longer works with my Livio Internet Radio although it worked perfectly for many months and my Mac Book continues to work perfectly accessing the Internet. The third time I called Cisco tech support  they told me the E1000 was discontinued

  • Cant get macbook pro to send midi signals

    I have a new Macbook pro running 10.8.2 and I am trying to send midi singals to an Elation Magic 260 light controller. I have an M-Audio Midisport USB Uno connected from the macbook to the magic 260. I have installed the drivers for the uno, I can se

  • Material PO Text in display mode