Read only derived atribute

Hi,
Is it possible to have a read only derived attribute with toplink? For instance the attribute managerName on the employee would be populated by a pl/sql function.
The generated SQL would have to look like this
EMPNO, JOB, COMM, MGR, SAL, HIREDATE, ENAME, DEPTNO,
manager_api.get_managerName(EMPNO) MANAGER_NAME
FROM EMP
Would I be able to build something like this by extending DirectToFieldMapping or is it not meant to be used that way?
I don't want to use custom select SQL because then ExpressionBuilder won't work anymore.
Thank you,
Calin Medianu

I thought of that, but can not do it. I am generating my mappings from a legacy repository that looks very much like an oracle designer repository + a lot of other metadata. I'd rather not create a view because then I have to generate views + insteadof triggers for all my tables and cannot do that for some non-technical reasons.
I'm not necessarily looking for an easy solution, I kind of need to get it right. In my case the requirement is to populate the attribute from a pl/sql function that I call with the PK of the current row as an argument.
I solved this by using a converter that converts that PK column to a QueryBasedValueHolder, then my program works but uses lazy fetching (which I don't want) and I could not get it to use bind variables (which annoys the DBA). I wrote about this in here populating attribute from result of pl_sql function another limitation of this solution is that I can not use more that one column as input to the pl/sql function, which would be a nice thing to have.
Thanks a lot for taking the time to respond.
Calin

Similar Messages

  • Can't mount USB disk with the atribute of  fix and read-only

    Hello All,
    I have a usb disk which is set as fix(non-removalbe) and read-only. I tried to connect it to Macbook version 10.4.11 ,but it failed to mount the disk. However, connecting to 10.5.X and windows XP work fine. I am wondering is it a bug specifically in 10.4.11 only ? Could I get any patch for this problem ?
    Thanks,
    Ying

    HI Ying and Welcome to Apple Discussions ...
    Try repairing disk permissions.
    Quit any open applications/programs. Launch Disk Utility. (Applications/Utilities) Select MacintoshHD in the panel on the left, select the FirstAid tab. Click: Repair Disk Permissions. When it's finished from the Menu Bar, Quit Disk Utility and restart your Mac.
    Carolyn

  • I am in the process of expanding a database of chemistry journal articles.  These materials are ideally acquired in two formats when both are available-- PDF and HTML.  To oversimplify, PDFs are for the user to read, and derivatives of the HTML versions a

    I am in the process of expanding a database of chemistry journal articles.  These materials are ideally acquired in two formats when both are available-- PDF and HTML.  To oversimplify, PDFs are for the user to read, and derivatives of the HTML versions are for the computer to read.  Both formats are, of course, readily recognized and indexed by Spotlight.  Journal articles have two essential components with regards to a database:  the topical content of the article itself, and the cited references to other scientific literature.  While a PDF merely lists these references, the HTML version has, in addition, links to the cited items.  Each link URL contains the digital object identifier (doi) for the item it points to. A doi is a unique string that points to one and only one object, and can be quite useful if rendered in a manner that enables indexing by Spotlight.  Embedded URL's are, of course, ignored by Spotlight.  As a result, HTML-formatted articles must be processed so that URL's are openly displayed as readable text before Spotlight will recognize them.  Conversion to DOC format using MS Word, followed by conversion to RTF using Text Edit accomplishes this, but is quite labor intensive.
      In the last few months, I have added about 3,500 articles to this collection, which means that any procedure for rendering URL's must be automated and able to process large batches of documents with minimal user oversight.  This procedure needs to generate a separate file for each HTML document processed. Trials using Automator's "Get Specified Finder Items" and "Get Selected Finder Items", as well as "Ask For Finder Items"  (along with "Get URLs From Web Pages") give unsatisfactory results.  When provided with multiple input documents, these three commands generate output in which the URLs from multiple input items are merged into a single block, which yields a single file using "Create New Word Document" as the subsequent step.  A one-to-one, input file to output file result can be obtained by processing one file at a time, but this requires manual selection of each item and one-at-a-time processing. What I need is a command that accepts multiple input documents, but processes them one at a time, generating a separate output for each file processed.  Is there a way for Automator to do this?

    Hi,
    With the project all done, i'm preparing for the presentation. Managed to get my hands on a HD beamer for the night (Epason TW2000) and planning to do the presentation in HD.
    That of course managed to bring up some problems. I posted a thread which i'll repost here . Sorry for the repost, i normally do not intend to do this, but since this thread is actually about the same thing, i'd like to ask the same question to you. The end version is in AfterEffects, but that actually doesn't alter the question. It's about export:
    "I want to export my AE project of approx 30 min containing several HD files to a Blu Ray disc. The end goal is to project the video in HD quality using the Epson  EMP-TW2000 projector. This projector is HD compatible.
    To project the video I need to connect the beamer to a computer capable of playing a heavy HD file (1), OR burn the project to a BRD (2) and play it using a BRplayer.
    I prefer option 2, so my question is: which would be the preferred export preset?
    Project specs:
                        - 1920x1080 sq pix  (16:9)
                        - 25 fps
                        - my imported video files (Prem.Pro sequences) are also 25 fps and are Progressive (!)
    To export to a BRD compatible format, do i not encounter a big problem: my projectfiles are 25 fps and progressive, and I believe that the only Bluray preset dispaying 1920x1080 with 25 fps requests an INTERLACED video  (I viewed the presets found on this forum, this thread)... There is also a Progr. format, BUT then you need 30 fps (29,...).
    So, is there one dimension that can be changed without changing the content of the video, and if yes which one (either the interlacing or the fps).
    I'm not very familiar with the whole Blu-ray thing, I hope that someone can help me out."
    Please give it a look.
    Thanks,
    Jef

  • Session state protection and read-only items

    I have a requirement to create a report + form for a database table. In the form, there is mandatory database column that needs to be displayed but it should be read-only and its value derived using values entered elsewhere on the screen.
    It tried Display Only, Read Only and Disabled but they either fall foul of session state protection violation or ORA-01400: cannot insert NULL. The best method that I've found was to add readonly="readonly" the item element, but this causes the input item to lose its APEX classes and I'd prefer a declarative solution anyway.
    Anyone know the best approach?
    I've created a DEMO - http://apex.oracle.com/pls/apex/f?p=READONLY - which demonstrates the 4 methods.
    Edited by: KGelling on 17-May-2012 06:10

    KGelling wrote:
    The best method that I've found was to add readonly="readonly" the item element, but this causes the input item to lose its APEX classes and I'd prefer a declarative solution anyway.Looks like a bug to me. However a possible explanation/justification for this behaviour is that the HTML Form Element Attributes are often used to specify a custom class for the item, so the default class is removed to prevent any conflicts. IMO APEX needs to provide declarative support for the use of multiple, space-separated class values in page, region, item etc attributes.
    As a workaround in this case, just include the class in the HTML Form Element Attributes:
    class="number_field" readonly="readonly"
    I've created a DEMO - http://apex.oracle.com/pls/apex/f?p=READONLY - which demonstrates the 4 methods.
    Thanks for making the effort.

  • Trying to modify PDF w/ no security, says it's opened as "read only to prevent modification"

    what am I missing here?
    The PDF in question can be found here:
    http://wndw.net/
    The PDF has a Creative Commons license saying I can:
    "Copy, distribute and display the book. Make derivative works, including books and articles. Make commercial use of the book"
    When I download and open the PDF, it is listed as having no security, but there's a blue info bar along the top in Acrobat X saying "The file you have opened complies with the PDF/A standard and has been opened read-only to prevent modification."
    I actually just trying to remove any hyperlinks and color information on some of the pages so we can reduce our printing costs.
    any ideas on how to open this NOT in read-only mode?

    You can temporarily disable PDF/A mode in Acrobat and/or remove the PDF/A information: http://blogs.adobe.com/acrolaw/2011/05/how-to-remove-pdfa-information-from-a-file/

  • Database open for read-only access ORACLE

    while building a universe with a dblink betweens oracle databases, i try to create a derived table in the form
    select field1 from table@db_to_db2
    but i get the following message:
    Exception: DBD, ORA-16000: database open for read-only acces State N/A.
    I understand the statement "Set Transaction for read only"  must be set before any transaction during the session, but still dont know how to trigger it in bo universe designer.
    Can someone know how to solve it?

    I suggest you fill-in the BEGIN_SQL parameter on the Universe to turn on the read-only transaction.
    Here is an excerpt from the Universe Designer guide:
    The BEGIN_SQL parameter allows you to prefix SQL statements with the same parameters each time a SQL statement is generated.
    1. Open the "Universe Parameters" dialog box in Designer.
    2. Click the Parameter tab.
    3. In the "Parameter" list, select the BEGIN_SQL parameter and enter the
    appropriate prefix commands.
    4. Save the settings.
    5. Save the universe.

  • Iomega external hard drive either 'not found' by Time Machine or is now in 'read only' format

    I don't know what's going on with my iomega external hard drive.  Sometimes the HD is recognised by the computer; other times it isn't; if it isn't I can restore to an earlier back up via Time Machine app; but it's like the disk isn't writable.
    Ten days ago, I had trouble backing up my iMac using Time Machine.  After turning it off and restarting my external hard drive, it backed up successfully.
    However, today I am trying to back up my files, and TM tells me it can't find the external hard drive.  Nothing has changed -- I have been out of town this past week -- but somehow my HD now seems to be in 'read only' format.  It does turn on, and I could restore my computer to an earlier back up.
    "Mac OS X can't repair the disk.  You can still open or copy files on the disk, but you can't save changes to files on the disk.  Back up the disk and reformat it as soon as you can."
    Annoyingly, despite my HD not showing in Finder or on my Desktop (as it usually does), when I simply turn it off I get that warning message "The disk was not ejected properly".
    Have tried verifying and repairing using Disk Utility, to no avail. 
    Am prompted to reformat but I don't have a good understanding of what this means and how to do it.  I'm guessing this would wipe the disk clean and I'd have to create the initial back up image all over again -- I'm reluctant to do this since this HD is my only back up and if it all goes tits up I'll be up that famous creek without a paddle.
    Thoughts, suggestions, input all welcome and deeply appreciated -- thank you!

    fzgy wrote:
    "Mac OS X can't repair the disk.  You can still open or copy files on the disk, but you can't save changes to files on the disk.  Back up the disk and reformat it as soon as you can."
    It's possible a heavy-duty 3rd-party disk repair app can fix it, but they're expensive (DiskWarrior is about $100), and there's no guarantee it can do it.
    Am prompted to reformat but I don't have a good understanding of what this means and how to do it.
    That will erase it.  See Time Machine - Frequently Asked Question #5.
    It sounds very much like the disk is beginning to fail, although it's possible there's a bad port, cable, connection or power supply (if it has its own).
    I'd suggest getting a new one, and using it for your Time Machine backups; once you have a good backup there, reformat the old one (and select Security Options to write zeros to the whole drive -- if that fails, you know the drive is toast).  Use it for secondary backups, per FAQ #27.   If it has failed, get a second new one for secondary backups. 

  • Fields for creation of BP in cProjects front-end are read-only

    Hi everyone,
    I'm a beginner in SAP-Development/Customizing so I hope this question isn't too easy
    I can't create a Business Partner using the cProjects front-end (Ressources > Staffing) because the necessary fields and buttons are read-only... (> web-Dynpro Component: DPR_ROL_STAFF; View-Info: VI_SEARCH_CREATE)
    I'm using CPRXRPM 450_700 patch 0006
    The field-control is standard-SAP (0SAP).
    My user-account has all cProject-roles + SAP-ALL
    I assume i can change the behaviour of these fields in the Field Control but I can't identify which is the corresponding Object Category to apply the changes.
    - Is there a documentation which field belongs to which Object Category in Field Control?
    - Or can somebody tell me a procedure to find it out on my own?
    Thanks in advance

    Hi,
    generally it is recommended to use transaction BP or ALE distribution to get the business partner be created.
    If you would like to create the BP in web UI directly, the user must have the Structural Authorization, see customizing path:
    Collaboration Projects -> Resource Management -> Organizational Management.
    It is very HR related topic, you may contact a HR consultant to know more details about it.
    Kind regard,
    Zhenbo

  • Generally when creating a Word file from either a Mac or Win7 pc and opening it on two different machines (either one first) it always prompts that the file is open and will be opened as read only. However opening a CSS file does not prompt that it is alr

    Generally when creating a Word file from either a Mac or Win7 pc and opening it on two different machines (either one first) it always prompts that the file is open and will be opened as read only.
    However opening a CSS file does not prompt that it is already open on or from any machine which is causing code edits to be lost.
    What we found from out testing:
    - The file can be saved from one user to the server and WILL NOT PROMPT on other machines until the saving machine has the Dreamweaver program closed completely
    - The file can be closed and  Dreamweaver minimised to the launch bar but it still will not register on other machines that it has been changed.
    - Also, until the  Dreamweaver program is closed on the machines, it will continue to open it's saved version of the file. 
    Example Scenario:
    - User 1 opens test.css (which is 2000 lines) and adds some code to the end of the file to bring it up to 2500 lines
    - Meanwhile User 2 opens test.css as well (opens as 2000 lines as User 1’s edits have not yet been saved) and adds in code to bring it to 2300 lines
    - User 1 saves his file and closes it - but  Dreamweaver is still open.
    - User 2 also saves his file and leaves  Dreamweaver  open.
    - The server will report the size and last edit of the file the same as User 2 as he was the last person to save it (and if you open from the Win7 Machine it will show as User 2’s 2300 line version)
    - If User 1 then open's the file again (from either the 'recent' in Dreamweaver OR clicking on the file directly in Finder...which version opens.... The version that User 1 saved! Not the true version on the server, but the version that User 1 edited and saved with 2500 lines in it.
    - Same for User 2, he will open 'his' version with 2300 lines in.
    Other information:
    - Files are opened directly from the server
    - Sometimes the users will save incrementally and re-open
    - Most of the time users will save incrementally and keep the files open
    - The users will never not save incrementally and just save when closing the file once finished
    - The users are usually working on the files all day
    - It is always the bottom lines of code that are lost. It could be a case of the two versions being mixed up and cutting off the newly added lines based on the line count (possibly).
    It is as if Dreamweaver is holding a cache of the version locally and then only properly looking back to the server when it has been completely closed. It is very difficult to see how the server is causing such an impact on these files, there are very few logs which are giving any indication to the root cause of the problems.
    Anyone know if this is a known issue?
    Is there a way that there can be a featured implemented on the server that doesn't allow another user to open a file if it is already open on another machine?
    Thanks

    Your server file handling has nothing, and really nothing to do with Adobe software. If files don't get locked for (over-)writing and/or lose connection to the program opening them, then your server is misconfigured. It's as plain and simple and that. Anything from "known file types"/ file associations not being set correctly, MIME types being botched, crooked user privileges and file permissions, missing Mac server extensions, delayed file writing on the server, generic network timeout issues and what have you. Either way, you have written a longwinded post with no real value since you haven't bothered to provide any proper technical info, most notably about the alleged server. Either way, the only way you can "fix" it is by straightening out your server and network configuration, not some magic switch in Adobe's software.
    Mylenium

  • Read Only access for a Maintenance view

    Hi All,
    I have a requirement like this.
    There is a Z Maintenance View (namely ZVHR_GRD_TARGET), for this i have to maintain the status as Read Only, and have to create a transaction code for this view with only SE16 access.
    I am doing like this.
    In the Z view, in the tab "Maint. Status", i have selected the radio button "Read Only" and saved it.
    I have created a transaction code for this view with SE16 access with the inputs
    Transaction                                                           SE16
    Selected the check box "Skip Intial Screen"
    Selected the check box for GUI status
    Name of the Screenfield                                          DATABROWSE-TABLENAME
    value                                                                      ZVHR_GRD_TARGET (i.e, view name)
    But the transaction code is not executing.
    So can any help me out in the requirement
    Regards
    Srinivas Kodukula

    Anchorage,
    Please refer to the following link:
    Read Only Schema in Oracle APPS 11i
    http://oracle.anilpassi.com/read-only-schema-in-oracle-apps-11i.html
    You may also search this forum as the same topic was discussed here many times before.

  • Can no longer select text in email template or read only field with mouse using IE or Firefox?

    Hi Guys,
    I can no longer select text in email template or read only field using my mouse in IE or Firefox anymore. We are using CRM 2011 rollup 18 applied with IE 11 and the latest version of Firefox. We only applied roll up 18 in Feb when this issue began.
    Thanks
    Dave
    David Kelly

    When you have a problem with one particular site, a good "first thing to try" is clearing your Firefox cache and deleting your saved cookies for the site.
    (1) Bypass Firefox's Cache
    Use Ctrl+Shift+r to reload the page fresh from the server.
    (You also can clear Firefox's cache completely using:
    orange Firefox button ''or'' Tools menu > Options > Advanced
    On the Network mini-tab > Cached Web Content : "Clear Now")
    (2) Remove the site's cookies (save any pending work first) using either of these. While viewing a page on the site:
    * right-click and choose View Page Info > Security > "View Cookies"
    * Alt+t (open the classic Tools menu) > Page Info > Security > "View Cookies"
    Then try reloading the page. Does that help?
    These features rely on JavaScript, and it sounds as though you have scripting enabled if you get (the wrong) color changes. Some add-ons might alter the way scripts operate, so a standard diagnostic to bypass interference by extensions (and some custom settings) is to try Firefox's Safe Mode.
    First, I recommend backing up your Firefox settings in case something goes wrong. See [[Backing up your information]]. (You can copy your entire Firefox profile folder somewhere outside of the Mozilla folder.)
    Next, restart Firefox in Firefox's Safe Mode ([[Safe Mode]]) using
    Help > Restart with Add-ons Disabled
    In the dialog, click "Start in Safe Mode."
    If those features work correctly, this points to one of your extensions or custom settings as the problem.
    To also disable plugins, you can use this page:
    orange Firefox button ''or'' classic Tools menu > Add-ons > Plugins category
    Any change?

  • Read Only Display of Radio group and Text area with counter not working

    Hello,
    I am using Apex 3.2, with 10g for the database
    I have this form, with fields that will set to read only when status = 'closed'
    All of the fields display as read only except for 2. I cannot figure out why this is not working correctly.
    1st field is Issues that is a text area with character counter, with a sql query behind it, that is set to null unless the query is pulling in the data.
    2nd field is Status which is a radio group that will not display as read only when status = 'closed'
    I have other fields on the form with the same format and they change to read only when the status = 'closed', I have even copied the pl/sql expression from one field to these fields and it still doesn't work correctly. I have also tried javascript for an on load event, which works, but once I click on the save button, it disables all of the page items, which works correctly, but I purposely forget to enter information, to make sure the validations are firing correctly, which it does, but the script disables everything, not allowing me to correct the errors. The javascript is firing on the on page load event.
    Any help on this is greatly appreciated.
    Mary

    Dung,
    That API seems to have a bug, it returns true/false/null, so you could use 'return not nvl(htmldb_util.current_user_in_group(p_group_name => 'APP Admin'),false)' to get a false value.
    Unfortunately there's another problem: using the read-only attributes for checkbox or radiogroup item makes them hidden. My suggestion would be to create another item that has disabled="disabled" in the HTML Form Element attribute in the item definition and display that item or the non-disabled item alternately, using conditions based on the current_user_in_group logic.
    Scott

  • Fields appear as "Read Only" in an Int.Form called from a WD

    Hi Experts!
    I am having a doubt in an Adobe Int.Form, that is called from a WD application.
    The fields that are in my Form, always appear as a "read only". It is not possible to modify anything there.
    Here, I describe the steps that I follow.
    I create a very simple WD application. In its WD View, exist an unique Object (Adobe Interactive Form).
    In that object, I set the properties:
    "Data source": a context variable type "my structure". "My structure", is a simple structure with a couple or three fields, let´s say PERNR, BUKRS, WERKS... It is linked to the Form Interface (ABAP DICTIONARY-BASED INTERFACE). So in this way, the link between my WD and the AdobeInt.Form is working.
    "PDF Source": a context variable type XSTRING.
    "Template Source": here I have set my Int.Form. Currently, it only contains a couple of fields
    "Enabled": True.
    "Read Only": False.
    In the AdobeForm, I have drag & droped those 2 or 3 fields, save it, and activate it. I guess nothing more is needed, for my test.
    And at last, in the View´s method WDDOINIT, I am reading one of those fields, let´s say the employee number (PERNR), and I set by hardcoding its number (let´s say -> 00000001).
    Until here, everything seems to work fine. When I launch the WD test, the Adobeform appears, at the moment, with only one of my fields (Employee - PERNR), and its value is filled in with '00000001'.
    But now, I would like to write something by myself. And when I try to do it, it is not possible! Field PERNR, is displayed as a "READ ONLY".
    Someone knows what is happening here? I guess it should be possible, to activate as a "EDITABLE" that field in my Form.
    So here is my doubt.
    Am I doing anything wrong? Or am I doing any mistake?
    Thank you very much in advance!

    Finally I think I have found the problem.
    In the View where I am printing the ADOBEFORM, it is needed this code under the method WDDOMODIFYVIEW.
    method WDDOMODIFYVIEW .
      DATA: LV_INTERACTIVE_FORM   TYPE REF TO CL_WD_INTERACTIVE_FORM,
                 LV_METHOD_HANDLER     TYPE REF TO IF_WD_IACTIVE_FORM_METHOD_HNDL.
      LV_INTERACTIVE_FORM ?= VIEW->GET_ELEMENT( 'INT_FORM' ). "   adobeform object in view
      IF LV_INTERACTIVE_FORM IS NOT INITIAL.
          LV_METHOD_HANDLER ?= LV_INTERACTIVE_FORM->_METHOD_HANDLER.
          LV_METHOD_HANDLER->SET_LEGACY_EDITING_ENABLED( ABAP_TRUE ).
          LV_METHOD_HANDLER->SET_HIDE_NAVIGATION_PANEL( ABAP_TRUE ).
          LV_METHOD_HANDLER->SET_DISABLE_PRINT_BUTTON( ABAP_TRUE ).
          WD_THIS->M_METHOD_HANDLER ?= LV_INTERACTIVE_FORM->_METHOD_HANDLER.
          WD_THIS->M_METHOD_HANDLER->SET_HIDE_TOOLBARS( ABAP_TRUE ).
        ENDIF.
    endmethod.
    Regards,
    Carles

  • Read only user creation for Oracle EM Console 11.1.1.5

    Dear All.
    I have created Read only user for Oracle EM Console.
    I have followed below link to do the same
    http://moshe-soa.blogspot.com/2011/09/blog-post.html.
    I have noticed with read only user is that TEST button in EM Console is active means user with read only user can create a trans, in Prod scenario it is a risk.
    Raised a CR with Oracle and found that it is a bug
    Bug 14082464 - CANNOT DISABLE TEST/TEST WEB SERVICE BUTTON IN SOA EM COSOLE is there in Metalink.
    So my question is there any way by which i can disable the TEST button in EM Conasole.
    I think there are some WLST script or servlet java class available to resolve this issue.
    Can any one confirm this and please suggest if any one aware of any alternative method.
    Thanks,

    Hi, have you got any solution to this problem? I am having exact the same issue in 11.1.1.6.

  • Fields in read-only mode for BP transaction in upgrade from 4.72 to ECC6.0

    Hello,
    This is regarding the query for BP transaction in upgrade from 4.72 to ECC 6.0.
    While creating BP / Changing BP system is disabling the fields in compnay code & sales area option. There is a SAP not provided 907860; and specified that the proplem is because of the delta customizing.
    All the customization settings are as per the note. And the Synchronization Control is also activated. But still the fields are disabled only.
    I have checked the field settings also in Cross-Application-Components & Logistic-Genral.
    But these are not working for compnay code & sales area data.
    please let me know if anyone has faced this type of problem / found any solution on this.
    Best Regards,
    Shubhada

    SAP IMG  -> Cross Application Components -> Master Data Synchronization  Synchronization Control -> Synchronization Control -> Activate Synchronization options
    This setting allows you to activate synchronization of BP with R/3. Not maintaining the values may result in certain fields being read-only in BP.
    Suggested Values:
    Source Object: BP | Target Object: CUSTOMER | Active Indicator : X
    Source Object: BP | Target Object: VENDOR | Active Indicator : X
    Source Object: CUSTOMER | Target Object: BP | Active Indicator : X
    Source Object: VENDOR | Target Object: BP | Active Indicator : X
    Have you set all of the above settings??
    BHARATH