Reciever Interface missing in SXMB_MONI

Hi,
When an XML message is generated in my backend ECC 6.0 system, SXMB_MONI does not show any entry in the Reciever Interface coloumn.
Hence the message will never go to the PI server.
SLD & SM59 connections are working fine.
Could we be missing out on something?
Thanks a lot,
Saba.

Hi Saba
Check with Michel's Blog I cannot see some of my messages in the SXMB_MONI
/people/michal.krawczyk2/blog/2005/05/10/xi-i-cannot-see-some-of-my-messages-in-the-sxmbmoni
also Check ur SMQ1 & SMQ2 Transactions.
Suppose if any queues are struck the messages are not coming to Receciver side,.
Check ur XI system & Receiver system
Regards
Abhishek
Edited by: Abhishek Agrahari on Jan 14, 2009 8:23 AM

Similar Messages

  • Wrong Reciever message interface name in SXMB_MONI in PI7.1

    Hi All,
    Some of the interfaces that are getting executed in PI7.1 have wrong reciever message interface name in SXMB_MONI view.
    In SOAP Envelope
    1.Reciever message interface name is getting populated in <SAP:Sender> tag and 
    2. Sender message interface name is getting populated in <SAP:Receiver> tag.
    But the end to end message flow is getting executed succesfully.
    It is not particular to any one of the interfaces. It is occuring randomly.
    Did any one encounter this problem earlier?Please share your inputs to resolve the same.
    Thanks,
    Younus.

    Hi,
    The SAP note mentioned - contains details specific to SOAP Adapter.
    The problem which we have mentioned is occurring across adapters.
    Even in SICF transaction. All the details have been correctly maintained.
    Any further steps to resolve the issue will be helpful.
    Thanks,
    Younus

  • Messages Missing in sxmb_moni

    Hi every one,
    There are some messages missing in sxmb_moni? I have checked the queues: smq1, smq2
    -Naveen.

    Hi,
    did you activate the trace?
    /people/michal.krawczyk2/blog/2005/05/10/xi-i-cannot-see-some-of-my-messages-in-the-sxmbmoni
    BTw
    are you sure those messages should be in the XI?
    do you see your message in:
    http://hostname:portnumber/MessagingSystem/monitor/monitor.jsp
    Regards,
    michal

  • Report -use r interface missing

    hi,
    while executing the report i'm getting message status gui1000 of user  interface missing& standard icons like back/save etc at top are all greyed out.
    PL suggest

    Are executing a custom report ? i think your gui-status is missing or not active.. search thru the code and find where the line
    set pf-status 'gui1000'.
    double click on this line , system will prompt you with instructions to create or activate

  • Entry missing in sxmb_moni

    Hi,
    My interface recived meeages through http and uses a BPM for some other synchronous calls in the flow.
    We were testing negative test cases and asked the sender system to send a wrongly formatted message.
    but the problem now is that a message that was sent by a third party to XI entered the BPM and i can see the entry in the transaction 'sxmb_moni_bpe' but where it failed (as expected) but when i try to see the corresponding entry in transaction 'sxmb_moni' i'm not able to.
    It looks like the message hit the BPE but not the IE !
    However this did not happen in the test environment. Could any one who has a suggestion or experienced similar cases help ?

    Hi Bharath,
    Please check both LOGGING & LOGGING_SYNC parameters configuration on both TEST and PROduction environments
    baiscally these 2 or LOGGING_PROPAGATION parameter used to perform logging/tracing fuctionality globally of IE.
    Parameter LOGGING or LOGGING_SYNC (category RUNTIME) to activate logging of asynchronous or synchronous messages locally for the whole Integration Engine. This means that all service calls of all pipelines of this Integration Engine are logged.
    Parameter LOGGING_PROPAGATION (category RUNTIME) to activate logging globally. This means that message processing is logged until it is complete on all involved Integration Engines.
    And also, check how these 2 parameters are configured TRACE_LEVEL, TRACE_LEVEL_PROPAGATION for category RUNTIME in both the environments.
    Regards
    Sekhar

  • BC new interface - missing manage users

    Hi
    The new interface seems to be missing the "manage users" menu item . This was under admin menu dropdown in the old interface.

    Hi Liam,
    All the Docs for Partners (rebranding sites), Help and the video refer to the old interface (unless I don't know if there is a new location to download ) any plan to update those or I have to manually update all?
    Cheers
    Vince

  • Async Client proxy -PI - File scenario- Pipeline steps missing in SXMB_MONI

    Hi
    I made a scenario where an ABAP client proxy(in a BW system) pulls data from a BW table and push it to PI.
    In PI a Mapping is done to write an XML file and sump it to a desired location.
    It is working fine in the development environment(request send to PI and mapped into an xml file)..so i migrated it to the quality/test environment where it started failing(It is only visible till SXMB_MONI of Client system and not reaching PI in case of quality/test environment).
    I checked SLDCHECK in the Client environments (say DWC for development and DWA for quality) and it looks fine.
    All I could see is:
    In SXMB_MONI of development system DWC--> Steps that are followed are
    Inbound Message
    Call Integration Server
    Response
    In SXMB_MONI of quality/test system DWA-->The only step is
    Inbound Message
    Could this be an Integration Server issue ??
    Please advise !!
    Regards,
    Naina

    check and compare the the parameter are set in SXMB_ADM of Dev system with Quality system.
    u can refer this blog for steps.
    /people/michal.krawczyk2/blog/2005/05/10/xi-i-cannot-see-some-of-my-messages-in-the-sxmbmoni
    chirag

  • Response payload missing in SXMB_MONI

    Dear All,
    I have a query related to Response payload in SXMB_MONI.
    I am using IDOC-XI-FILE & FILE-XI-IDOC asynchronous scenario . Output xml files and idocs are generated properly.
    <b>In SXMB_MONI,when I click on successful processed message it is not showing me the Response payload-MainDocument(application/xml).</b>
    <b>I was able to see response payload in my Development server but in production server I am not able to see the reponse payload.</b>
    I am using SP15.
    I tried to activate services also using t-code SICF but not able to solve the problem yet.
    Can anybody suggest me solution to this problem.

    Hi Prabhat,
    we had the same problem when we upgraded to SP15, we consulted SAP and they came up with the answer that this is a known bug in SP15. This seems to have been fixed in SP16.
    Regards,
    Roberto
    See Re: SXMB_MONI does not show payload after upgrade to SP15
    Message was edited by: Roberto Viana

  • File Missing in SXMB_MONI

    Hi,
    I am reading a fixed width file using File sender adapter.
    The data in the fixed width file is
    Header1
    Item1
    Item2
    Item3
    Header2
    Item1
    Item2
    Header3
    Item1
    In the recordset structure it is defined Header,,Item,
    Header.fieldFixedLengths = 1,22
    Header.endSeparator = 'nl'
    Header.fieldNames = TYPE,CODE
    Header.keyFieldName = 'H'
    Header.lastFieldsOptional = YES
    Header.ignoreRecordsetName = true
    Item.fieldFixedLengths = 1,10
    Item.endSeparator = 'nl'
    Item.fieldNames = TYPE,QTY
    Item.keyFieldName = 'I'
    Item.lastFieldsOptional = YES
    Item.ignoreRecordsetName = true
    In the data type the definition  of file is
    <Message Type>
    <Recordset>
    <Header>            Ocurrance 1 to unbounded
        <TYPE>
        <CODE>
    <Item>              Occurance 1 to unbounded
        <Type>
        <QTY>
    The file is read but not shown in Message monitoring and SXMB_MONI.
    but if i change the cardinality of recordset structure  from Header,1,Item,1
    I get the file in sxmb_moni but the structure is wrong.
    Can any one tell what is wrong ?
    Regards,
    Monzy

    Monzy
    I dont think there is a Name value pair key called..
    <field>.keyFieldName
    Check this one..it should be
    Key Field Name = TYPE in the content conversion params and these entries in the namevalue pairs
    Header.keyFieldValue=H
    Item.keyFieldValue=I
    Remember to remove the quotes - ' from the Value..The records pciked have to be chked for H not 'H'
    Hope this solves ur issue

  • Synchronous interfaces missing in Java proxy generation

    Hi,
    In PI 7.1 ESR, in "Java proxy generation" wizard, it only lists the Asynchronous interfaces from the software component version. None of the synchronous interfaces are listed.  how can I solve this? I need to generate a java proxy for a syncronous interface.
    thanks and regards,
    Raghu

    Make sure that the inteface pattern is "stateless (XI 3.0 compatible)".

  • Outbound Message Missing from SXMB_MONI IN ECC

    Dear PI Experts,
    I have created IDOC to File scenario, But I am facing error when i am sending data from idoc using  tcode we19 . 
    ERROR is whenever
    I have checked tcode SXMB_MONI IN ECC server  but XML message  is not showing in this tcode  ,whereas  XML message is showing in tcode SXMB_MONI  of PI server .
    Please help me .

    Hello Diptee ,
    I have checked both case of IDOC and screenshots are referenced .
    Case 1  .
    Tcode BD10  ,
    Case 2 .
    Tcode WE19,

  • HID interface misses reports if mouse is connected on the same hub

    Hello all,
    I have designed a usb based oscilloscope for my device (HID Full Speed). It works fine. But when i connect the mouse to the same hub as the device, my device starts missing reports frequently. I have verified it both through my own software and a third party
    software (USBLyzer) which shows that the PC doesn't poll my device every millisecond, which it should. 
    I have searched thouroughly but didn't find anyone facing the same problem. It would be very nice of you if you could help me identify and correct the problem. I have tested it on different PC also
    Thanks
    Regards Waqas Ehsan Butt

    Your hub is probably running out of "juice". If you power the hub via the USB cable connected to your PC then it can draw a maximum of 500 mA which it must distribute between its own electronics, the CRO and the mouse. To solve the problem you must use an
    external power supply for the hub (if it has a suitable socket) or purchase a different hub that comes with its own power pack.

  • ITunes COM interface missing

    I have recently updated to iTunes 8 (8.0.0.35 on Windows XP Pro). I was using a little self-written C# application to control iTunes using my mouse's special buttons (the mouse driver supports this out of the box, however not in the way I want it to).
    After the update, the application stopped working throwing an “interface not supported” 0x80004002 E_NOINTERFACE error. When I tried recompiling the tool from source, there was an error loading the iTunes COM interface. When checking the list of available COM interfaces in Visual Studio I noticed the “iTunes {VersionNumber} Type Library” interface was not listed.
    Did Apple remove the iTunes Type Library COM interface or was there just some error while installing iTunes 8 so it did not get registered?
    Btw: You don't need Visual Studio to check whether the COM interface is available; a lot of other applications allow using COM interfaces aswell, i.e. Visual Basic for Office (go to Tools » References and search the list for iTunes; my system lists iTunesAdmin, iTunesOutlookAddIn, iTunesPhotoSupport)

    I have heard of several people having this issue.
    Refer to this thread:
    http://discussions.apple.com/thread.jspa?messageID=8048746&#8048746
    Maybe you can figure out which registry settings to add/delete...
    But you can apparently also fix it by:
    1) uninstalling iTunes 8
    2) Installing iTunes 7.7
    3) Uninstalling iTunes 7.7
    4) installing iTunes 8 again
    (reference http://groups.google.com/group/itunes-com-developers/browse_thread/thread/61918c cf74a32e8)
    Fun, right?

  • XML Error Message for Every one hour in SXMB_MONI

    Hi All,
    I am getting XML error Message for every one hour in PI when I check in SXMB_MONI I can see this.
    Details Below
    Sender Componant : PI
    Sender Interface : SAPCCMS
    Reciever Interface/Reciever Componant : Both are empty.
    PI Version 7.1
    Can anybody help in this.
    Dayakar

    Hi!
    I was just searching this about this problem and found a post that might interest you.
    [urn:SAPCCMS;
    cheers

  • PI 7.1 Sender Interface and Receiver Interface  gets interchanged

    Hi All,
    I m facing a strange problem in PI 7.1
    For many of my scenarios, the Sender Interface, sender namespace and receiver Interface, receiver namespace  information gets interchanged and displayed incorrectly.
    But sometimes its working fine.
    When we analysed the Log messages, found that, after xml validation step, the sender and reciever interface gets interchanged.
    Any idea why this happens?
    How to rectify this error?

    Aarthi,
    Please check your message interfaces once again. Sender is outbound and Receiver is inbound.
    Also please check your receiver determination.
    Regards,
    ---Satish

Maybe you are looking for

  • Safe download box in safari preferences?

    Is it a good idea to uncheck the safe download box the safari preferences?  I 've seen people talk about this & I'm new to the mac world.   THANKS!

  • Organizational structure graphical view

    Hi Friends, we have problem with the organizational structure graphical view in OM. the system can not read the texts fonts, we don't use english characters. what should we do? Thanks

  • Content based retrival in intermedia

    If I have human bodies stored in intermedia. Like for each person one image of his body. Can I go and run a query show me all those bodies that have a particular kind of dot in the body[the real images are more complicated than this we are storing he

  • Foreign apple care + battery issues

    Hi people, I tried searching for similar issues but it seems I have several of them combined. And I've just about gone crazy with this issue so I need to hear your opinion/advice. I was living in the States in 2008 and in September I bought my 15" MB

  • USB mouse disconnects when laptop on battery

    Hello, I am using Gnome 3.6 on 3.6.10-1-ARCH. Whenever I run my laptop on battery power, my external usb mouse disconnects after some inactivity period. If I plug it to external power source, it again starts working fine. I suspect there must somethi