Reg: Cache settings

Hi,
We have a database of size 15KB only but has data from 1999 to 2008.The main issue is retrieval performance is too low.To increase the performance of the database retrieval can we increase the below cache size's or is there any other option?
Our database has the below settings:
Mode:Buffered I/O
Existing blocks: 1900000
Index cache:30000KB,Data cache:200000KB
Please suggest on this.

Hi,
Below is some tuning info which you will hopefully find of interest:
1 - The index cache setting should equal the size of your index files (ess000001.ind). Note that you you may have several essxxxx.ind files in your environment since a new file is created for every 2GB.
In the Database Properties screen, select the Storage tab and check the size of each .ind file. Remove the last 3 digits to obtain the value to enter in the Index Cache field (convert from KB to MB)
2 - The Data File Cache is only used with Direct I/O (No need to set it when using Buffered I/O). It should equal the data file size (ess000001.pag). Remember 1 .pag file is created for every 2GB.
3 - The data cache should be set to 0.125 times the values of the data file size (ess000001.pag). Again you may have several essxxxxx.pag files in your environment, 1 for every 2 GB.
You then need to restart the databases for the changes to take effect.
You may need to look at your isolation mode to improve performance maybe?
Committed Isolation: the calculation is stored to a temp directory before being written to the server. => Better data consistency
Uncommitted Isolation: Essbase releases a block after it is updated but does not commit blocks until the transaction is completed or until a specified limit is reached => Better performance and data concurrency
Hope this helps.
Seb
www.taysols.com.au

Similar Messages

  • Cache settings in BI7. Data still not displayed correctly in RSRT

    Good day
    Please assist? I did scan SDN for a similar problem and did check the CACHE settings in RSRT etc.
    My problem is: If I check the data in the DSO, then the updated information that was loaded yesterday is displayed. When I run the query, it does not display the last loaded information. I have run the query in RSRT and the updated information does not display either. I have changed the cache properties of this query to different settings already, and running the query from RSRT, with no success.
    I also checked the query itself (design) It is not restricted to anything. User selects 0CALMONTH as variable only. I have logged out and in again after each Cache setting, no success of displaying the updated DSO information.
    Can anyone please tell me why the query does not pick up the latest information from the DSO?
    Thanks in advance.
    Cj

    Hi Cj,
    Is the last request marked as Ready for Reporting? This needs to be the case before the latest data comes up in the query.
    Hope this helps!
    Regards,
    Saurabh

  • LR 5.5 - Camera RAW Cache settings reset non-stop

    Lightroom doesn’t remember the folder path in Camera RAW Cache Settings section in File Handling tab in Preferences window. I want to set my own folder Camera Raw Cache and its maximum size but every time Lightroom sets default path (C:/Users/Name/AppData/Local/Adobe/CameraRaw/Cache/) and also maximum size as 1GB. When I set all the parameters Camera RAW Cache and click OK or switch between the tabs in Lightroom preferences window or restart Lightroom and I return to the File Handling tab all the data is reset to default. The same happens when I want to change the parameters Camera RAW Cache from Adobe Bridge and Photoshop.
    Second question:
    When I use DNG file format with Embed Fast Load Data option in the folder Camera RAW Cache the “DAT” files doesn’t appear. Is it connected with the use of Embed Fast Load Data option? When I use the original NEF files from my Nikon “DAT” files appear.
    [Win 7 64-bit, LR 5.5, Web&Design CS6]

    I have no trouble placing my Camera Raw cache where I want to put it. Perhaps deleting your Preferences file would help with that problem.
    Yes, if you embed fast-load data in your DNGs, LR will use that instead of the CR Cache.
    Hal

  • PS CS6 / Bridge / ACR 8.5 - Camera RAW Cache settings reset non-stop

    Adobe Bridge/Photoshop doesn’t remember the folder path in Camera RAW Cache Settings in Camera RAW Preferences window. Every time when I want to set my own folder Camera Raw Cache and its maximum size, I click OK and return to Camera RAW Preferences, I see default path (C:/Users/Name/AppData/Local/Adobe/CameraRaw/Cache/) and maximum size as 1GB.
    [Win 7 64-bit, LR 5.5, Web&Design CS6]

    Problem is solved!
    I delete folder "C:\Users\USERNAME\AppData\Roaming\Adobe\CameraRaw\". Then I start Lightroom and I pick my own folder in Camera Raw Cache Settings, set 20GB size and click OK. Now everything works fine. Bridge and PS also fine.

  • Properly and accurately calculating application cache settings

    Hello everyone.
    We are running Hyperion Planning 11.1.2.1 and one of the dataforms we have set up is quite heavy (it includes several DynamicCalc members with considerable ammount of scripting) and it fails to load from time to time, just saying "Cannot open dataform X. Check logs" and such.
    I have tried to increase cache sizing in the databases of the Essbase application (right clic on each database > edit > properties > caches), as well as buffer sizes and commit blocks.
    Little by little I have managed to improve performance by modifying the above mentioned caches (it crashes less often), but still I guess it's nuts to infinitely increase caches to make sure it works.
    So, my question is: Is there a way to calculate the accurate cache settings for a given application?
    My current settings are:
    Buffer size: 200 KB
    Short buffer size: 200 KB
    Index cache setting: 30720 KB
    Data file cache setting: 61440 KB
    Data cache setting: 51200 KB
    Commit blocks: 30000
    Do you think these are accurate?
    Thanks a lot,
    G.S.Feliu

    You haven't really provided enough information to be honest, for example are you running a 64bit system?
    But that is rhetorical, as usual the first port of call is the DBAG. I don't see why a link should be posted, you must have access to it already if you're administering a production system. That will point out things like that the Data file cache setting is only relevant if Direct I/O is being used and that the index size should be at least as big as the file if memory allows.
    Commit blocks....is interesting, personally I have set it to 0 in some projects and seen some improvement but as usual testing is the key.
    However their is a performance tuning guide out there that you may find very useful:
    https://blogs.oracle.com/pa/entry/epm_11_1_2_epm1
    that focuses on the infrastructure a bit more. Bit complicated though and I would thoroughly recommend recording a set of benchmarks before applying any of those changes, and applying said changes one by one or you'll never know what is good and what is not so good.
    Learn from the pain others have already endured ;-)
    Good Luck
    Steve

  • Need to knw how to maintain cache settings for infoprovider in one go

    Hi,
    We are trying change the OLAP cache settings for the queries, as we know queries inherit the properties of InfoProvider so instead of changing for queries we need to change it for infoprovider. But we have 1000+ infoproviders, i want to know is there any way to change for all the infoproviders at one go"
    we have around 1100+ infoproviders in our BW system
    we would like to know what is the option to activate all the queries at
    a time
    Can you please let us know how to maintain the cache settings for all
    the infoproviders in one go
    and also like to know whether this will change the cache settings of
    the queries present now in the system
    Thanks & Regards,
    Syeda Nausheen Sulthana
    SAP BASIS | AtoS

    Hi Nausheen,
    You capture the steps that you do in changing the infocube properties in BDC.
    Create an upload file with all the cubes technical names and execute the BDC program in automated way.
    You can take help from ABAP expert in your team.
    Let me know, if you need more details.
    Thanks,
    Krishnan

  • Data Cache Settings

    Hello,
    I am coming up with the spreadhseet retreival error very frequently and get Essbase Error 1130203. I went through the Error interpretation and found that Data Cache might be causing it. Here are the details of cache settings on my
    databases currently. Can somebody please help me understand if they are right or need some changes:
    DataBase A:
    Data File Cache setting (KB) 32768
    Data cache setting (KB) 100000
    Block Size: (B) 143880
    Number of existing blocks: 7266
    Page file size: 40034304
    DataBase B:
    Data File Cache setting (KB) 32768
    Data cache setting (KB) 300000
    Block Size: (B) 91560
    Number of existing blocks: 1912190
    Page file size:2147475456--1
    Page file size: 500703056
    DataBase C:
    Data File Cache setting (KB) 300000
    Data cache setting (KB) 37500
    Block Size: (B) 23160
    Number of existing blocks: 26999863
    Page File Size: 21 page file =21 * 2= 42 GB
    If this might not be the issue then please let me know what might be causing it?
    Thanks!
    Edited by: user4958421 on Dec 15, 2009 10:43 AM

    Hi,
    1. For error no 1130203, here are the possible problems and solutions, straight from document.
    Try any of the following suggestions to fix the problem. Once you fix the problem, check to see if the database is corrupt.
    1. Check the physical memory on the server computer. In a Windows environment, 64 MB is the suggested minimum for one database. In a UNIX environment, 128 MB is the suggested minimum for one database. If the error keeps occuring, add more memory to the server computer.
    2. If you are on a UNIX computer, check the user limit profile.
    3. Check the block size of the database. If necessary, reduce the block size.
    4. Check the data cache and data file cache setting. If necessary, decrease the data cache and data file cache sizes.
    5. Make sure that the Analytic Services computer has enough resources. Consult the Analytic Services Installation Guide for a list of system requirements. If a resource-intensive application, such as a relational database, is running on the same computer, the resource-intensive application may be using the resources that Analytic Services needs
    Sandeep Reddy Enti
    HCC
    http://hyperionconsultancy.com/

  • Cache Settings

    Hello,
    I am coming up with the spreadhseet retreival error very frequently and get Essbase Error 1130203. I went through the Error interpretation and found that Data Cache might be causing it. Here are the details of cache settings on my
    databases currently. Can somebody please help me understand if they are right or need some changes:
    DataBase A:
    Data File Cache setting (KB) 32768
    Data cache setting (KB) 100000
    Block Size: (B) 143880
    Number of existing blocks: 7266
    Page file size: 40034304
    DataBase B:
    Data File Cache setting (KB) 32768
    Data cache setting (KB) 300000
    Block Size: (B) 91560
    Number of existing blocks: 1912190
    Page file size:2147475456--1
    Page file size: 500703056
    DataBase C:
    Data File Cache setting (KB) 300000
    Data cache setting (KB) 37500
    Block Size: (B) 23160
    Number of existing blocks: 26999863
    Page File Size: 21 page file =21 * 2= 42 GB
    If this might not be the issue then please let me know what might be causing it?
    Thanks!

    You have posted the same question on the essbase forum > Data Cache Settings
    You are more likely to get more responses on the essbase forum to this question.
    From the docs
    Error - 1130203     
    Essbase is unable to allocate memory.
    Possible solutions
    Try any of these suggestions to fix the problem. After you fix the problem, determine whether the database is corrupt (see Checking for Database Corruption).
    Check the physical memory on the server computer. In a Windows environment, 64 MB is the suggested minimum for one database. In a UNIX environment, 128 MB is the suggested minimum for one database. If the error keeps occurring, add more memory to the server computer.
    If you are on a UNIX computer, check the user limit profile (see Checking the User Limit Profile).
    Check the block size of the database. If necessary, reduce the block size.
    Check the data cache and data file cache setting. If necessary, decrease the data cache and data file cache sizes.
    Ensure that the Essbase computer has enough resources. Consult the Oracle Hyperion Enterprise Performance Management System Installation Start Here for system requirements. If a resource-intensive application, such as a relational database, is running on the same computer, the resource-intensive application may be using the resources that Essbase needs.
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • Database cache settings for 4.13 on NT 4

    The database cache settings and the documentation have always been
    confusing.
    I have about 35000 entries in my directory. If I have enough available ram
    should I try to put all the entries into ram? The default setting is a 1000,
    should I change it to 35000? Will I notice any great speed increases.
    And the second setting has to do with index cache. Should I try to get that
    into ram also? My id2entry.db2 file is about 40MBs. Should I change the
    default from 10MBs to 40MBs? Will there be a significant increase in speed?
    Thanks.

    Thanks Russ H for your quick reply.  I am still fairly new to FCP X coming from using FCE not iMovie.
    The project I'm working on I had already started before posting yesterday.  Is it possible to change the settings for what I have already done, or no I need to start all over again?
    Thanks again
    Matt

  • BW cache settings and WebI

    Hello,
    we're trying to tune the BW cache for WebI queries, we'd like to change the default cache settings for a number of queries, including ones used for BO universes.
    I'd like to know if this changes will be picked and used by WebI or if it is not sensitive to such changes (Cache Mode and Persistence Mode).
    Thanks in advance for your help.

    Hello Pablo,
    I haven't tried yet but the OLAP cache should be used by WebI when it accesses the queries. You can ensure it does in transaction RSRCACHE by looking at the last access of a cached query. Could also look at the BI stats (if you have installed them and turned then on of course).
    Regarding the cache settings, I would personally recommend using the persistent cache (across App Servers if you have more than one app server) into a Cluster table (or Transparent table if the data set is quite large). Can find more details here: http://help.sap.com/saphelp_nw70ehp1/helpdata/en/d9/31363dc992752de10000000a114084/frameset.htm
    You could also look into MDX cache instead of OLAP cache, but I haven't played with it yet so I'm not sure it would help with WebI. Anyone else did?
    Hope it helps...

  • How can I configure Cache settings ? Frequency , capacity ?

    How can I configure cache settings like capacity and frequency? System is very slow . We experience system degradation.

    # type about:config in the browser's location bar, and then press Enter.
    # If a warning displays, click I'll be careful, I promise!.

  • Tuning search server cache settings

    In search cluster manager under WCI Administration utilities in WCI Portal console, we see a warning msgs as below:
    -Docset cache size used does not match the recommended size for this configuration
    -Index cache size used does not match the recommended size for this confguration
    How to tune the search server cache settings?

    Actually, I think these configurations should be done (in WCI 6.5 or higher) in the configuration.xml located in /alui/settings.
    See Search Service Will Not Start, Token Count Exceeds Default Threshold [ID 879512.1]
    Contents in the file
    <component name="searchserverinternal" type="http://www.plumtree.com/config/component/types/searchserverinternal">
    <setting name="RFINDEX">
    <value xsi:type="xsd:string">index</value>
    </setting>
    <setting name="RF_CLUSTER_HOME">
    <value xsi:type="xsd:string">../alui/ptsearchserver/6.5/cluster/</value>
    </setting>
    <setting name="RFPORT">
    <value xsi:type="xsd:integer">15250</value>
    </setting>
    <setting name="RF_DOCUMENT_TOKEN_CACHE_SIZE">
    <value xsi:type="xsd:integer">250000</value>
    </setting>
    <setting name="RF_SPELL_TOKEN_CACHE_SIZE">
    <value xsi:type="xsd:integer">50000</value>
    </setting>
    <setting name="RF_MAPPING_TOKEN_CACHE_SIZE">
    <value xsi:type="xsd:integer">2500</value>
    </setting>
    <setting name="RF_INDEX_CACHE_BYTES">
    <value xsi:type="xsd:integer">78643200</value>
    </setting>
    <setting name="RF_DOCSET_CACHE_BYTES">
    <value xsi:type="xsd:integer">26214400</value>
    </setting>
    <setting name="RF_TOKEN_LEXICON_REBUILD_LIMIT">
    <value xsi:type="xsd:integer">[INCREASED VALUE]></value>
    </setting>
    <clients>
    <client name="searchnode01"/>
    </clients>
    </component>

  • LR4 cache settings...not staying?

    So...I know...LR4 is acting slow...
    But part of the problem is that when I change the cache settings in my preferences, they're not being remembered after I close the preference box.
    By default, the settings are for a 1GB cache in a folder: user/Library/Caches/Adobe Camera Raw.
    I go in, change them to a new location, increase the size to something more effective...and then open up preferences again, only to have them dumped back to the default.
    The only reason I'm still using this program (and not jumping back to LR3) is that it's the only thing that will read my 5DIII files!
    Does anybody have a similar issue?
    John

    Nobody has a similar issue??

  • Firefox cache settings no longer working

    Firefox cache settings that were working are no longer working, in Windows XP (x86) and Windows 7 (64).
    By this I meant that I had set the cache to a ram-drive, but that is no longer being used, the cache is being written to disk instead in what is apparently the new default location, and my customized cache settings are ignored.
    I've tried resetting Firefox to default and then re-applying them, but the problem still exists.
    This is for FF 19+, but not sure when the problem first occurred - perhaps an earlier version too.
    Is it no longer possible to re-direct the cache directory? How do you do it?

    For jumpListCache , I found that setting browser.taskbar.lists.enabled to false prevents their capture:
    http://forum.palemoon.org/viewtopic.php?f=13&t=1985&start=10

  • Cache settings impact

    Hi experts,
    I d like to know if cache settings in a cube have impact on the retreival performance as well?? or it impacts only the calcs performance ??
    tried searching the forum but cud nt find a solution

    Hi Dave,
    Good question,
    1) Calculations performance depends on your cache ettings.
    http://docs.oracle.com/cd/E17236_01/epm.1112/esb_tech_ref/frameset.htm?maxl_export.html
    2) Retrieval performance is based on member storage properties.
    Also cache settings impact your calculation performance as well retrieval performance.
    Thanks.

Maybe you are looking for

  • Problems with updates after upgrading to CS4

    I am experiencing update problems after upgrading from CS3 to CS4. After completing the upgrade, I opened CS4 and then clicked on 'Help' and 'Updates'. The download was 280MB of updates, which duly started to install. However, during the install proc

  • Using a camcorder to record video and an interface to capture the audio

    Here is what I am trying to do: Use my camcorder to record the video and use a mic connected to an audio interface to record the audio portion of the video. Here is how my set up looks like: I have an M-Audio firewire audio interface connected to my

  • Dv7-3065dx esata port multiplier

    Anyone know if the dv7-3065dx esata port hardware can function as a port multiplier? I want to purchase a Thermaltake BlacX Duet USB 2.0 Portable External Hard Drive but it requires a port multiplier. I have the single slot thermaltake blackx right n

  • I lost my files - How to get them back?

    HI GUYS, Recently I realized that some videos and picture's files simply disappear from my HD. I need a Disaster Recovery Software, Quick file recovery I think it was an accident file deletion or a hardware failure, but not a virus attack! What shoul

  • CS3 Web Standard to CS4 Design Premium

    Hi All, I'm having problems trying to install CS3 Web Standard and CS4 Design Premium. I bought CS 3 Web Standard Upgrade Version and CS4 Design Premium Upgrade, to update my old CS2 Standard. My question is: Can I install CS4 Upgrade If I don't have