Regarding Cisco 4500/6500 Power Supply

Hi ,
I am Rajesh, I want to know that can we check Cisco 4500/6500 power supply whether it is working or dead by connecting it directly with power source and without attching it to chassis.
Regards,
Rajesh

Hi ,
I am Rajesh, I want to know that can we check Cisco 4500/6500 power supply whether it is working or dead by connecting it directly with power source and without attching it to chassis.
Regards,
Rajesh

Similar Messages

  • Cisco 4500/6500 switch

    Hello Freinds,
    I have two querries:-
    1)
    a) What would be the effect if one SUP is removed (out of two) from Cisco 4500/6500 series switch.
    b) what is the result after removing both SUP from cisco 4500/6500 switch.
    ++++++++++++++++++++++++++++++++++++
    2) PLease share the step wise process for upgrading IOS on 4500 switch (with 2 SUP card).

    http://www.cisco.com/en/US/products/hw/switches/ps663/products_configuration_example09186a00801461ef.shtml

  • Cisco 6500 power supply and module (hot-swappable?)

    Hi everyone!
    We have currently a Cisco 6500 with 2 power supply of 3000w. We want to replace these PS for 2 new ones, which have higher wattage: 6000w. 
    Can we replace them without needing to turn the 6500 off?. I mean, What happens if we insert a 6000w PS and the switch is working with one 3000w PS?
    Is it possible to do this replacement "on hot"?
    And second, we also have a ws-x6708-10g-3c module. Can we insert this module "on hot"? Without needing to turn the Catalyst 6500 off? 
    Thanks a lot! and looking forward to an answer.

    Depends on your setup the table should be able to help:
    http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst6500/ios/12-2SX/configuration/guide/book/pwr_envr.html#wp1020384
    Configuration Change
    Effect
    Redundant to nonredundant
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Nonredundant to redundant (both power supplies must be of equal wattage)
    •System log and syslog messages are generated.
    •System power is decreased to the power capability of one supply.
    •If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in theshow power oper state field.
    Equal wattage power supply is inserted with redundancy enabled
    •System log and syslog messages are generated.
    •System power equals the power capability of one supply.
    •No change in module status because the power capability is unchanged.
    Equal wattage power supply is inserted with redundancy disabled
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Higher or lower wattage power supply is inserted with redundancy enabled
    •System log and syslog messages are generated.
    •The system does not allow you to operate a power supply of different wattage even if the wattage is higher than the installed supply. The inserted supply shuts down.
    Higher or lower wattage power supply is inserted with redundancy disabled
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Power supply is removed with redundancy enabled
    •System log and syslog messages are generated.
    •No change in module status because the power capability is unchanged.
    Power supply is removed with redundancy disabled
    •System log and syslog messages are generated.
    •System power is decreased to the power capability of one supply.
    •If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in theshow power oper state field.
    System is booted with power supplies of different wattage installed and redundancy enabled
    •System log and syslog messages are generated.
    •The system does not allow you to have power supplies of different wattage installed in a redundant configuration. The lower wattage supply shuts down.
    System is booted with power supplies of equal or different wattage installed and redundancy disabled
    •System log and syslog messages are generated.
    •System power equals the combined power capability of both power supplies.
    •The system powers up as many modules as the combined capacity allows.

  • Cisco 3850 Redundant Power Supply Reporting Issue

    We have deployed several Cisco 3850's. Several are showing the following symptom
    ont2-tc3-es01#sh env power
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    1A  PWR-C1-715WAC       DCB1702G0QU  OK              Good     Good     715
    1B  PWR-C1-715WAC       DCB1702G0G6  No Response     Good     Good     715
    Every single switch at this particular location has the same status on the B power supply. The problem was there on the previous code level (3.2.2) and we recently upgraded to 3.3.5 to resolve some SNMP bugs on the switches we also expected the latest Assurewave version to fix this issue also. So couple questions:
    1. Anyone else seeing this?
    2. Anyone found a fix for it?
                   Thanks!
                              Marty

    Hi Zabeel,
                       I did talk with TAC - per the engineer there are two bugs that cause the issue and one was fixed in 3.3.5 - so we upgraded all our 3850's to that code level. Unfortunately for us, that still didn't fix the issue. TAC suggested that it may be fixed in rev 3.7.0, but that has not officially been confirmed by Cisco's developers.
             We're waiting for the official "fix" before going through another round of switch upgrades.
            TAC did suggest reseating the power supply if you still have the issue after the upgrade to 3.3.5 - but that's not really an option for me since my switches are geographically spread out.
       HTH
                 Marty

  • Cisco 3850 Dual Power Supply - One No Response

    Hey Guys,
    I am getting multiple switches on my network showing "power supply failure" from Solarwinds.
    I am running Cisco 3850s running v 03.02.03.SE cat3k_caa-universalk9 iOS, and they all have dual power supplies. When i do the sh env power, I get this output.
    SWITCH1#sh env power
    SW  PID                             Serial#     Status               Sys Pwr  PoE Pwr  Watts
    1A  PWR-C1-715WAC       xxxx           OK                 Good     Good           715
    1B  PWR-C1-715WAC       xxxx         No Response   Good     Good           715
    SWITCH2#sh env power
    SW  PID                              Serial#     Status           Sys Pwr    PoE Pwr     Watts
    1A  PWR-C1-715WAC       xxxx           OK                   Good     Good          715
    1B  PWR-C1-715WAC       xxxx         No Response     Good     Good          715
    When I physically go down to look at the switches, they have green lights, so they are receiving power, but I keep getting the PSU failure alerts.
    Do you think it is an iOS issue, and should I upgrade? Or has anyone else seen this?

    Hi,
    I think below Bug could match with your issue.
    "power supply B is not responding" reoccurring on Catalyst switches
    https://tools.cisco.com/bugsearch/bug/CSCun41735/?reffering_site=dumpcr
    And we can see workaround of this issue is HW workaround.
    Thanks,
    Jack

  • Ciscoview Cisco 6509 VSS power supply LED indicators incorrect

    Hello all
    i am experiencing the following problem.
    In the Ciscoview, the LED indicators of the power supply of Cisco 6509 VSS are represented incorrectly. All power inputs and fans are okay actually. however, in the ciscoview, there is only 1 green "INPUT OKAY" for each power supply. And "FAN OKAY" LEDS are off on Active chassis.
    Any assistance would be greatly appreciated.
    LMS 4.1
    IOS Version 12.2(50)SY1
    Device Package:
    38.
    Cat6000
    12.0
    Cat6000 Package
    39.
    Cat6000IOS
    37.0
    Cat6000IOS Device Package

    Check the PS at the back, is there a light?  If there's no light, then you need to RMA the PS as it could be faulty.
    If there's a light on the PS, then you need to RMA the switch. 

  • Cisco 7603-S power supply

    Hi,
    i have cisco 7603-S router with 1500W DC power supply. As per documentation, there is one input per power supply. I want to know the Electrical Cable specification (thickness of the cable in Sqmm)for the 1500W DC power supply, also type of lugs if required.
    Regards

    Hi Zabeel,
                       I did talk with TAC - per the engineer there are two bugs that cause the issue and one was fixed in 3.3.5 - so we upgraded all our 3850's to that code level. Unfortunately for us, that still didn't fix the issue. TAC suggested that it may be fixed in rev 3.7.0, but that has not officially been confirmed by Cisco's developers.
             We're waiting for the official "fix" before going through another round of switch upgrades.
            TAC did suggest reseating the power supply if you still have the issue after the upgrade to 3.3.5 - but that's not really an option for me since my switches are geographically spread out.
       HTH
                 Marty

  • Cisco 6500 Power Supply and related configurations if any?

    Hi,
    My query is with regards to the best practices deployed for connecting Cisco 6509 switches in the DC, attached is the existing and proposed setups, also would appreciate getting the related switch configs to acheive redundancy and high availability of the switches in the DC network.
    Regs,
    Mahesh

    Hi,
    this depends on what power-supplies you have and how loaded your chassis is.
    For Example:
    When your chassis is loaded with
         1x Sup720
         8x GE-TX Linecard (WS-X6748)
         2x 3kW Power-Supplies (WS-CAC-3000W)
    Then you have to run the chassis in Combined-Mode because, even if there is no second Sup, the same power is allocated to the second sup-slot as if there were one installed.
    Having 2x 6kW Power-Supplies, then you should run your chassis in Redundancy-Mode and go with your proposed setup.
    for combined-mode use:
    cat6k(config)# power redundancy-mode combined
    for redundancy-mode use:
    cat6k(config)# power redundancy-mode redundant
    verify with:
    cat6k# show power
    system power redundancy mode = combined
    Hope this helps!
    regards,
        Dirk

  • Power supply from a Dell

    Hi Everyone
    So i just ordered a W540 as my work PC too swap out my old Dell latitude.
    My company is trasferring from Dell to lenovo setups in all the offices.
    We move arround with our laptops so we have a lot of extra power supplys from Dell (19.5 V 3.34A with round plugs).
    My question is, will we be able to use an adapter like this one (http://www.ebay.com/itm/2PCS-New-Power-converter-Cable-Adapter-For-Lenovo-ThinkPad-Carbon-0B47046-/3...) to power our laptops instead of buying loads of new power supplies?
    Best Regards
    Kim
    Solved!
    Go to Solution.

    kimdt27 wrote:
    Hi Everyone
    So i just ordered a W540 as my work PC too swap out my old Dell latitude.
    My company is trasferring from Dell to lenovo setups in all the offices.
    We move arround with our laptops so we have a lot of extra power supplys from Dell (19.5 V 3.34A with round plugs).
    My question is, will we be able to use an adapter like this one (http://www.ebay.com/itm/2PCS-New-Power-converter-Cable-Adapter-For-Lenovo-ThinkPad-Carbon-0B47046-/3...) to power our laptops instead of buying loads of new power supplies?
    Best Regards
    Kim
    No. That power supply will supply 65 W at the most, which is nowhere near the amount of power required for the W540. You could try to rig it to work on an X240, which takes about that much power, but a W540 requires a 170 W supply due to its power hungry CPU and GPU.
    W540: i7-4700mq, K2100m, 8 GB DDR3L, 512 GB SSD
    T510: i7-620m, NVS 3100m, 8 GB DDR3, 512 GB SSD

  • ASUS U81A Power Supply- Extra Adapter

    Just ordered an extra U81A Power Adapter from http://jacobsparts.com/
    We'll see if they are legit (only $18.00)

    kimdt27 wrote:
    Hi Everyone
    So i just ordered a W540 as my work PC too swap out my old Dell latitude.
    My company is trasferring from Dell to lenovo setups in all the offices.
    We move arround with our laptops so we have a lot of extra power supplys from Dell (19.5 V 3.34A with round plugs).
    My question is, will we be able to use an adapter like this one (http://www.ebay.com/itm/2PCS-New-Power-converter-Cable-Adapter-For-Lenovo-ThinkPad-Carbon-0B47046-/3...) to power our laptops instead of buying loads of new power supplies?
    Best Regards
    Kim
    No. That power supply will supply 65 W at the most, which is nowhere near the amount of power required for the W540. You could try to rig it to work on an X240, which takes about that much power, but a W540 requires a 170 W supply due to its power hungry CPU and GPU.
    W540: i7-4700mq, K2100m, 8 GB DDR3L, 512 GB SSD
    T510: i7-620m, NVS 3100m, 8 GB DDR3, 512 GB SSD

  • Cisco Power Supply error

    What does out of regulation limits means ?
    1 red "OUTPUT FAIL," normally is off but illuminates when power supply outputs are out of regulation limits
    Thanks
    Rosa

    Hi,
    Seet this:
    LED
    Meaning
    INPUT OK
    AC-input power supplies:
    •Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.)
    •Off—Source AC voltage falls below 70 VAC, is not present, or the PEM is turned off.
    DC-input power supplies:
    •Green—Source DC voltage is OK. (-40.5 VDC or greater.)
    •Off—Source DC voltage falls below -33 VDC or is not present at the PEM.
    FAN OK
    Green—Power supply fan is operating properly.
    Off—Power supply fan failure is detected.
    OUTPUT FAIL
    Red—Problem with one or more of the DC-output voltages of the power supply is detected.
    Off—DC-output voltages within acceptable margins.
    Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal.
    This is for 6500 switches but apply to almost all models.
    http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Chassis_Installation/Cat6500/0apwsply.html#wp1025570
    Hope this helps.

  • Power supply of Cisco WVC210 Camera with batteries

    I want to use my new WVC210 Wireless-G PTZ Internet Video Camera on my wheeled robot, so I would like to provide a  separate power source for this camera.
    Can I use 4 "D" batteries for it? They give 6 V DC, not 5 V as written  on the camera.
    I've measured the voltage coming out from the power supply, which came  with the camera. In Switzerland it outputs 5.39 V DC.
    I am afraid 6 V DC may damage the camera. Or is it OK?
    If 6 V is not OK, then another possibility is 4 x 1.2 V DC researchable  batteries. But it gives only 4.8 V DC.
    Can camera be supplied with only 4.8 V DC? Or is it better to use 6 V DC?
    Or I shall build DC-DC converter outputting exactly 5 V?
    In specifications for the Cisco WVC210 it is written: "5V DC 2.0A switching power supply". But how tolerrant is the switching power supply? Will it work safely with 6 - 5.8 V?

    I'm afraid we can't recommend using any power source other than the AC adapter included with the camera.  Using anything else would likely void your warranty also.
    Regards,

  • Power supply part number for Cisco 2900

    I need to know what are the part numbers for installing the redundant (second) power supply.

    Hi,
    Have you tried sh inventory.
    I am able to see with same command on some different platform
    #sh inventory | inc Power|SN
    NAME: "slot 24", DESCR: ***** AC Power Supply"
    PID: 34-0820-01 rev B0 dev 0, VID: V01, SN: CAB014501HN
    Regards
    Mahesh

  • Odd power supply fault callhome emails on Cisco 2232 FEXs?

    We recently enabled smtp callhome for our ucs pod a few days ago. Since then, we've received more than a dozen email bursts about power supply failures in each of the four Cisco Nexus 2232TP FEXs in our pod. In each case, we get a "Recovered" email within a minute or two, and we're not seeing power supply failure emails for any other devices within the UCS pod.
    Here's a sample email burst from this morning, showing the subject lines within my email inbox:
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 power: error
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 power: error
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:01:27 GMT-00:00 Recovered : Power supply 2 in fex 6 power: error
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 operability: inoperable
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 power: error
    System Notification from atl01-ucsf01a-A - environment:major - 2012-10-23 06:00:58 GMT-00:00 Power supply 2 in fex 6 power: error
    If we were seeing this from just one fex, I'd suspect a hardware issue. If any of the other UCS devices (rackmount/blade servers, fabric interconnects, etc) reported similar issues, I'd suspect a power feed problem within the DC.
    But this has me baffled. If it helps, the UCS pod is running firmware 2.0.3c
    Cheers,
    Paul

    Thanks Paul,
    It is known ( cosmetic ) issue with power supply model. 
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCtz84683
    The above is resolved in recent version of Nexus 5K switch software. New defect to port the fix to UCSM has been submitted today
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCuc87547
    It will take a while to get published on web site.
    Even though they are cosmetic, I would suggest you open a TAC SR with UCSM, FEX tech support and above bug IDs so that we can track the resolution.
    HTH
    Padma

  • Power supply error, Cisco switch 3750

    Hello,
    Can someone help me with a  power supply problem...?
    Switch cisco WS-C3750-24P is showing "Unavail" from sh env all
    Switch3750#sh env all
    FAN is OK
    TEMPERATURE is OK
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    1  Built-in                                         Unavail
    2  Built-in                                         Good
    3  Built-in                                         Good
    4  Built-in                                         Good
    Does it means that power supply 1 was removed? failed?
    Do you know about another command to see more details?
    Thanks,

    Hi All,
    Can you please help to fix the issue,
    sw03#sh env all
    FAN is OK
    TEMPERATURE is OK
    Temperature Value: 45 Degree Celsius
    Temperature State: GREEN
    Yellow Threshold : 58 Degree Celsius
    Red Threshold    : 68 Degree Celsius
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    1  Built-in                                         Unavail
    SW  Status          RPS Name          RPS Serial#  RPS Port#
    1   Active          <>
    sw03#sh env st
    SWITCH: 1
    FAN is OK
    TEMPERATURE is OK
    Temperature Value: 45 Degree Celsius
    Temperature State: GREEN
    Yellow Threshold : 58 Degree Celsius
    Red Threshold    : 68 Degree Celsius
    POWER is FAULTY
    RPS is SUPPLYING
    As per the sh env stack, seem like power is faulty ?. Can Someone please tell how to rectify the problem.
    Madan

Maybe you are looking for

  • IMac Thunderbolt ports stopped working

    I have a late 2012 iMac 27". Both Thunderbolt ports no longer work. Have tried an external monitor and hard drive. Nothing happens. Both work on another iMac. Reset PRAM (left cmd+option+p+r), but nothing changed.

  • PS Extended Video Import Problem

    I cannot find any other reference to this problem in the FAQs or FORUMS. I cannot import any video files into PS Extended (10.0.1) without a Photoshop crash. The crash is caused by quicktime.qts file. I have tried to re-install quicktime several time

  • Translation add-ons for safari

    I'm looking for an add-ons for Safari to traslate by selecting and right-clicking over word or phrase. I used Firefox with add-ons gTranslate that use Google Translate service. Exist something for Safari too?

  • Received Error: Platformvwersion "7.0.1" not compatible with Minversion:1.9.2.13 Maxversion:1.9.2.13 Can't get Firefox to work and no email with Thunderbird?

    Firefox running well on IBM compat Windows 7/64 bit. No Outlook so adding Thunderbird. Added Thunderbird and received the Error: Platform version "7.0.1" NOT compatible with: Minversion: 1.9.2.13 Maxversion: 1.9.2.13

  • Workflow / Early archiving

    Hi Workflow and Archiving Experts - We are currently doing early archiving with workflow for Incoming Invoices, using the "Store for Subsequent Entry Option". The process is as follows: 1. Document is scanned 2. Using Transaction OAWD the scanned doc