Regarding Enhancing Standard Infotype

Dear All,
We have a requirement where in we need to enhance a Infotype which already got enhancement.
I have added a new field in ci_xxxx include of that infotype through PM01. It alreay has a custom field called A and now I want to add Custom field B. But I do not see that field when I open this infotype using PB30. Please advice whether I need to regenerate this infotype or what I need to do so that existing development ( validations or checks) will not get effected and I should be able to see my field there.
Thank you very much in advance.
Waiting for your response.
Best Regards,
Amar

Hello,
You need to regenerate the Infotype for the new field to reflect in the Infotype screen.Add the custom changes again.
Hope you have selected both radio button for generating the Infotype for applicant as well employee data.
Alternate way is you need to add the new field to the Infotype screen manually .You can do this from SE51.From PM01 you can dierctly goto screen painter by chosing the Screen radiobuton.
Once You have added the field to the screen ,you also need to make the declarations for the field in the module pool program.
Regards,
Malathi V

Similar Messages

  • Enhance Standard Infotype 1005 in HR

    Dear All,
    Please suggest how to enhance standard infotype 1005 - Planned Compensation in HR.Transcation PM01 is not allowing to do so ...as no CI include is attached for the same.
    Please guide.
    Regards,
    Subhash

    hi,
      maybe you can achieve your requirement by creating a new custom OM infotype
    ( if the custom information are linked to the OM entity :  org unit, positions.. ) or a new PA infotype ( if the custom information are linked to the employee ) .
    Regards luigi
    Edited by: luigi la motta on Sep 2, 2011 11:46 AM

  • Impact of enhancing standard infotypes on service pack upgrade

    Hi SAP experts,
    I have a situation where in we had enhanced standard infotype 14 ( added custom fields to structure CI_P0014) in development systems and moved to production systems. Now these changes should be moved to project system in which the service pack upgrade is in progress. Will it impact the SP upgrade if I move my transports to these systems? Will it overwrite the sp changes for IT14?
    P.S : The support pack was not applied to the system in which the std infotype was enhanced.
    Regards,
    Sameena

    You should re-apply any customer enhancements etc to your development environment after SP's are applied - But only after you have a developer review potential impacts from SP and your development.
    I think you would be fine as IT14 isn't updated often in SP's.
    Cheers,
    Brad

  • Enhancment to standard infotype

    I have an urgent question.
    While mapping to legacy table, they have fields of char 180.
    Hence we need to enhance standard Infotype.
    However, I like to check if there is any screen design constraint.
    Also what is the total length/bytes of an infotype?
    How to check?

    ECC6.0 enhancement to the infotype is max of 500 btyes ie only 250 chars

  • Facing problem with call subscreen area in standard infotype

    Dear SAP Guru's,
    I have enhanced standard infotype 0185 from PM01, in assign enhancement tab it create multiple screens ,
    my program name ZP018500, screen number 0200 generated,
    on  0200 screen i need to display two subscreens tfor that
    i have created subscreen area  on srcreen 0200 which is already a subscreen.
    and i am calling two subscreen 0201 and 0202 on that  subscreen area.
    while creating entries for 0185 infotype  my screen keep going in continious loop for call subscreen statement on 0200 screen number.
    roll in fail, session terminated error coming because of this.
    is it correct to create subscreen area on subscreen and calling subscreen on that.
    Guide me to solve the issue.
    Thanks and Regards,
    Syed

    Dear Gopal,
    Thanks for the reply,
    But i can't make 0200 screen as normal screen because it is automatically generated by system while enhancing the standard infotype,
    Please let me know any other solution.
    Regards,
    Syed Taj

  • How copy changes in standard infotype using scc1

    hi,
    i m enhancing standard infotype 0022 adding single field using pm01 .
    changes are showing in our development client in pa30 screen,
    but when i copy the request to other client changes are not reflecting in pa30 screen.
    i checked changed screen layout it is showing that additional field but it is not showing in pa30.
    pls help.
    regards,
    sudhir ghag.
    SAP ABAP HR Consultant.

    Hi ,
    Pls check the entry in V_T582A in 2 different clients.
    This must be missing in other client.
    Transport this table entry.
    Hope this will work.
    Thanks
    Partha.

  • HELP CREATING ADDITIONAL FIELDS  WITH  DROPDOWN IN STANDARD INFOTYPE

    HI ALL,
    I AM IN ABAP-HR.
    I HAVE 2 THINGS 2 ASK MY FRIENDZ..
    1). I WANT TO ENHANCE STANDARD INFOTYPE...
    I  WANT TO PUT ADDITINAL FIELD WITH DROPDOWN...
    I CAN PUT ADDITIONAL FIELD BUT I DONT KNOW HOW CAN I DO WITH DROPDOWN...
    2).
    OTHERTHING I WANT TO CHANGE THE TEXTFIELD OF STANDARD INFOTYPE..
    I MEAN 2 SAY CHANGE TEXT 'BIRTHDATE' TO 'DATE'..
    CAN U PLZ HELP ME OUT 4 THIS....
    WAITING 4 FAVOURABLE REPLY..
    BBYE..

    Hello Bhumit,
    1) to check how to bring values to a dropdown please refer the standard demo report programs in se38
    a)DEMO_DROPDOWN_LIST_BOX
    b)demo_dynpro_dropdown_listbox.
    2)We need to understand that if the field label 'BIRTHDATE' is from a standard screen then the approach is to go to that particular screen ...delete the text and put our own text there as 'DATE' ..otherwise if the field is a custom field we can change the name in the field level or domain level
    Pls check,revert and reward if helpful
    Regards
    Byju

  • Enhance screen for standard infotype

    I need to enhance screen for standard infotype. I follow docs but nothing happens.
    Here is my process by steps:
    1. PM01 - select infty number
    2. PM01 - generating CI_PXXXX (customer include)
    3. create structure for this include
    4. create customer screen for this include
    5. PM01 - generate objects.
    Then I am redirected to SE19 - BAdI-Builder. What should I do follow?
    Created screen hasn't appear in se80 (MPXXXX00).
    Thank you in advance!

    I suggest you place your question in [ERP HCM forum|SAP ERP Human Capital Management (SAP ERP HCM);,

  • Enhancement to a standard infotype

    Hi all,
    I have added a check box to the standard infotype 0022
    provided with function code.
    i have used
                           program : ZP002200
                           screen : 200
    but it is inactive when i try to create a record in pa30
    so i want to know how to make these radiobuttons and check boxes active.

    Hi all,
    I have added a check box to the standard infotype 0022
    provided with function code.
    i have used
                           program : ZP002200
                           screen : 200
    but it is inactive when i try to create a record in pa30
    so i want to know how to make these radiobuttons and check boxes active.

  • PPCI  Tcode to enhance OM infotypes

    Hi All,
    I want to change the screen layout of a particular OM infotype ..say 1005 . And make one existing field as mandatory which is optional in the standard.
    In PA infotypes , there is an option to make this requirement satisfy  in customizing .
    Considering the OM infotype is there any way of doing it . Through PPCI how to do it . When the enhancement option is chosen , it navigates altogether to a new structure . A help is required regarding the OM infotype  giving a general view on it .
    Regards
    Gajalakshmi

    I am not sure but try the Badi HRBAS00INFTY method Before Output
    Balaji

  • Copy Standard infotype screen for country purpose

    Hi,
    I am trying to copy the Standard screen (2007) for the infotype IT0002 to make some country specific modification.
    However I am not able to copy the standard screen as it is asking for the Access Key.
    Can you please suggest if there is a way to copy the standard infotype screen without providing the access key.
    Regards
    Bharath

    Hi,
    Why don't you just enhance the infotype via PM01 - Enhance single screen?
    (MP000200 screen 2007)
    Regards,
    Dilek
    Edited by: Dilek Ersoz Adak on Feb 8, 2010 6:53 PM

  • Enhancing PD Infotype

    Hi all,
    How to enhance the Table Infotype in PD (as I know to enhance Field Infotype through PPCM) and may I know is it possible to enhance Table Infotype. If possible, pls help in this regard.
    Regards,
    V Kumar

    Hi nachiappan mv,
        Thanks for the reply and there is no information in the material of how to enhance the standard table Infotype and tried with PPCI and it seems there is no CI Include for Table Infotype and may I know how can I enhance the standard Table Infotype. Pls help in this regard.
    @ pratyush v
    I tried in PPCI but there is no CI Include for Table Infotype and may I know how can I enhance the standard Table Infotype. Pls help in this regard.
    Regards,
    V Kumar

  • Enhancing an Infotype

    Hi ,
    I need to enhance a standard infotype(0743 - Discipline Infotype) .This Infotype has subscreens(tabs).I need to add fields in these subscreens(tabs) . Going through transaction PM01 and enhancing an infotype allows new fields to be added in the main screen ( the common area) , and not the individual tabs .Is there any way to add fields in the tabs of a Standard Infotype ?
    Thanks in advance .
    Regards,
    Sujata

    search this question in the HR forum, this has been answered before
    SAP ERP Human Capital Management (SAP ERP HCM)

  • Enhancement in infotype 0006

    Hello,
    How to add custom address fields (Building and Apt No) to Infotype 0006. Could you give me the approach and sequence steps to accomplish this task.
    Regards
    RM

    Hi Ratnakar,
    To create custom fields in standard infotype 0006,
    Go to PM01 T-code.
    Go to enhance infotype tab.
    Enter your infotype number 0006 and choose "ALL" on the right of infotype's input box,instead of "CREATE" at bottom.
    This will lead you to the CI include structure creation.
    Here enter the fields that you want to add to your infotype and save and activate it.
    Chhosing "ALL" instead of "CREATE" all the components one by one will reduce the complexity and labour of your work.
    Chhosing "ALL" creates all the modules of the Module Pool program itself and appends the CI include in the table PA0006 itself.
    Thats It!!
    Regards,
    Tejas.

  • Regarding Enhancements in ECC 6.0

    Hi,
               This is Pavan. Can anyone explain in steps how to standard infotype in SAP ABAP-HR in ECC 6.0
    Thanks in advance

    Hi PavanVelamuri,
    Hope this would help you ,
    http://sample-code-abap.blogspot.com/2008/06/hr-abap-02-getting-started-ldb-pnp.html?showComment=1214678040000
    http://sapient.wordpress.com/category/abap-hr-development/
    Regards,
    Sreekar.Kadiri.