Regarding Logical systems
Hi all,
when i was trying to create new logical systems in trnsaction code BD54. It is said that you are not authorization to create logical systems. To get authorize what should i required?
venkat
Hi Venkatravi,
You can Create Your Own Logical System when you have an Access from the Basis People in our Company, They have to give You the Access.
<REMOVED BY MODERATOR>
Naresh.
Edited by: Alvaro Tejada Galindo on Apr 25, 2008 1:31 PM
Similar Messages
-
PLEASE HELP ME TO FIND THE SOLUTION REGARDING "LOGICAL SYSTEM CHANGED"
HAI EVERYBODY,
PLEASE HELP ME TO FIND THE SOLUTION REGARDING "LOGICAL SYSTEM CHANGED" during the material master replication by using middleware parameters.
step1 : i have taken SRM client 810 and named it as CHINNISRM
step2 : i have taken r3 client 810 and named it as CHINNIR3
step3: During material master replication i maintained tables like crmconsum,crmrfcpar,crmparoltp in r3 and smofparsfa in srm client and filtered the objects and loaded the objects through r3ac3,r3ac1,r3as.
step4 : And later i have checked in r3 queues to activate the objects,but i have seen a message like "LOGICAL SYSTEM CHANGED:SEE 588701".according to the oss instructions i have checked in CRMPRLS table in se16 in R3 .there i found out there is one logical client named with T90CLNT810.
oss :588701
Solution
There are different cases in which different forms of processing are
required or where several options exist:
- The logical system name of an R/3 Backend client was changed in
current operation. In this case, the data hangs in the outbound
queues of the R/3 Backend system as specified under point 1 of
the symptom. In this case, the logical system name must be
changed back to the original value. Then the outbound queues
can be reactivated. If no data was transferred to the EBP/CRM
server before the change, also a correctioin of the check table
is possible.
- The same logical system name was used again in a new client of
an R/3 Backend system that was linked to the EBP/CRM server. In
this case, the data is in the inbound queue of the EBP/CRM
server with the exception GUID_FOR_LOGSYS_CHANGED. In this
case, the queue entries which have status SYSFAIL must be rejected, however, not the entire queues. If the new client of the R/3 Backend system you have linked has exactly the same
data as the old client and if it is meant to replace the old
client (that is, this was deactivated), also a correction of
the check tables is possible. In this case, the inbound queues
can be reactivated after the correction.
oss:765018
1. If the situation in your system corresponds to the situation described
under "Reason and Prerequisites" and if symptom 1 occurs, you can
delete the table entry from table CRMPRLS table (there is just one
entry). Since there is no maintenance dialog for this table and you
cannot maintain it using transaction SE16, you must use a report to
delete it. This report is attached to this note as correction
instructions.
Create the report ZZ_DELETE_CRMPRLS in your system and copy the source
code from the correction instructions. You cannot implement this
source code using transaction SNOTE.
You can use the report in every plug-in or plug-in basis system, even
if it is not specified in the validity section.
After you have run the report, you can trigger existing queues again
in transaction SMQ1.
2. If the situation in your system corresponds to the situation described
under "Reason and prerequisite" and if symptom 2 occurs, you can
delete the entry from table CRMMLSGUID (there is just one entry).
Since there is no maintenance entry for this table and you cannot
maintain it using transaction SE16, you must use a report to delete
it. This report is attached to this note as correction instructions.
If they do not yet exist, add the following messages to message class SMOF in your logon language:
Message Message short text
303 User &1 is not allowed to change table &2.
304 User &1 IS not allowed to display table &2.
305 Logical system &1 was not found in table &2.
306 System error! The current client was not
found in table T000.
Create the report ZZ_DELETE_CRMMLSGUID in your system and copy the
source code from the correction instructions. You cannot implement
this source code using transaction SNOTE.
You can use the report for every release of the CRM system, even if it
is not specified in the validity section. The only exceptions are CRM
releases with Support Package versions that are too low such as CRM
Release 3.0 with Support Package 12.
After you have run the report, you can trigger existing queues again
in transaction SMQ1 of the R/3 back-end system or transaction SMQ2 of
the CRM system.
so what should i do to do the replication.please suggest me .untill and unless i solve my problem i cant move to the further activity.i hope you people can solve my problem.thanks in advance.
thanks and best regards,
n.chakradharHi chakradhar,
Did you find a solution to your issue? We are facing a similar issue and looking to figure out how this can be resolved.
BR// 420 -
Clarification Regarding Logical System Names
HI all,
I read the blogs regarding Logical System Name, even I am having the some problems in my system.
For PI system client is 100.
R/3 System Client is 100 is created.
IN PI when I checked the sale->basic setting-> LOgical Settings-> Assign Logical Systems
I found there is only one client 100, and it is having the same logical system name as 'PICLNT100'.
In SLD one Business System is created for Client 100 and having the Logical System Name is 'PICLNT100'.
When I checking in the R/3 system that logical system Name ('PICLNT100') is not there and for r/3 client 100 having the different logical system name.
IN ID when I found the Goto ID->File Buinsess system and Menu ->Services->Adapter Specific Identifiers->Logical Ssytem,
It is different from the SLD logical System Name.
How Can I know in PI, that Logical System is belongs to r/3 or PI client 100,
when I running the sceanrio it is giving error as ATTRIBUTE_INV_SND_SERV while doing the file to Idoc scenario.
How I have to maintain the logical system names in this case?
please help me in this.
Regards,
Sreehi.
each r3 system has his own SLN (PI,BI,ECC,etc). this name identify each R3 sytem.
http://help.sap.com/saphelp_nw04/helpdata/en/78/217dc151ce11d189570000e829fbbd/frameset.htm
IN ID when I found the Goto ID->File Buinsess system and Menu ->Services->Adapter Specific Identifiers->Logical Ssytem,
to export data of your R3 system to SLD, just do it from TCODE RZ70 in your r3 system, not PI.
once you configure it all data from r3 system is exported to SLD.
if the SLN does not match in Adapter Specific Identifiers->Logical Ssytem, edit the Bussines System (press in the little pencil) go to Adapter Specific Identifiers->Logical Ssytem and prees in the little hand icon. in the SLN in not refresh, go to menu enviroment--> CLEAR SLD DELTA CACHE. and repeat the steps before.
each time you send data to an R3 system and the sender system is a legacy. in your receiver communication channel>header mapping>sender system--> select the PI Bussines system and try again.
hope its helps
Rodrigo
PD: rewards points if useful -
Regarding logical system assigining to transport request
hi, all,
how to assign the transport request for logical system.,....because i transported the interfaces to quality system..please guided me in thisHello Sai
I am not sure about the meaning of your question.
You do no assign any logical system to a transport request but you must define the target system (see Properties of request). Calling the search help for this field you see that the target systems are coming from the active transport configuration (STMS).
Perhaps your question is about how to set the client in which the request is imported. Regarding workbench request containing client-independent objects it does not matter whether you import into client '000' or your productive client.
For customizing requests containing client-dependent objects you set the client when executing the import (either in STMS or via command line when calling the tp command directly).
Regards
Uwe -
Regarding logical system function module....
hi all,
i migrated one interface program from 4.7 to ecc...both are seperate servers.....its working fine in 4.7 system...when it came to ECC.there s no errors...but in testing they found tat some system id is missing like tat...in RFC they called one FM OWN_LOGICAL_SYSTEM_GET........please guided me in this....Ok sai. This interface is working in 4.7 why because it has the logical system name has been created and assigned to the client there. So, what you will do is take the logical system name given in 4.7. You can do that by going in to SALE tcode...under Basic Settings>Logical Systems>Assign Logical Systems
Here select the client name, and click on the button next to "change/display", that is the Details button. Here you can see the logical system name. Note that.
Now, in ECC 6.0, go into SALE tcode and then follow the same path...But instead of assign logical systems,select define logical systems. Now, click on New Entries button and then give the name you have in 4.7 and then give the same name in 6.0...and give a description. Save it..
Come Back,, now click on assign logical systems and then move into change mode....then select the client u logged in with and then click on details tab and here change the logical system name. Give the logical system name you just defined. Save it...and come out.
Now, try executing the Interface you migrated. And revert back with the error if there is any.
Vishwa. -
Hi can any body help me how to assign logical system to business system in SAP XI.please send me screen shots if anybody have it.
Hi,
Refer the below step by step help:
http://help.sap.com/saphelp_nw70/helpdata/en/42/c817d9d2296bb2e10000000a1553f6/frameset.htm
Also check the below link for screen shot:
SLD preparation very good:
https://www.sdn.sap.com/irj/sdn/wiki?path=/display/xi/flatFILETOFLATFILE&
Working with System Landscape Directory (SLD) :
https://www.sdn.sap.com/irj/sdn/wiki?path=/display/xi/workingwithSystemLandscapeDirectory+%28SLD%29&
Configuring SLD in Sneak Preview SAP NetWeaver '04 Sneak:
/people/sugree.phatanapherom/blog/2005/08/14/configuring-sld-in-sneak-preview-sap-netweaver-04-sneak
XI Software Logistics 1: SLD Preparation:
/people/sap.india5/blog/2005/11/03/xi-software-logistics-1-sld-preparation
Thnx
Chirag -
Confusion in Logical System, port & RFC Destination
hi,
I have still few doubts regarding Logical System, port and RFC destication
My SAP ECC6.0 and XI configuration is:
For ECC 6.0 : Logical system name : T03CLNT400
Client : 400
RFC Dest : XIDEST
Port : XIPORT
For XI 3.0 : Logical System name : WXI
client : 400
RFC Dest : ECCDEST
Port : SAPEC3
now my confusion is, in t-code WE19, when sending IDOC to XI (idoc - file scenario), which entry i've to use in prot and Partner No in Receiver side and which port and partner no i've to use in Sender Side.
also in XI side when creating Technical sys for web as ABAP which logical system name i've to use and in File to Idoc Scenario which logical system i've to use as sender business system (third party file business system)
If possible please give me detail idea to clarify my cofusion.
thanks
riteshRitesh,
<b>now my confusion is, in t-code WE19, when sending IDOC to XI (idoc - file scenario), which entry i've to use in prot and Partner No in Receiver side and which port and partner no i've to use in Sender Side.</b>
If you are sending from R3 then give the sender details as R3 and the receiver side as XI where you have created the port from R3 to XI etc.
Check this help for clear understanding on all this settings:
https://www.sdn.sap.com/irj/sdn/wiki?path=/display/xi/sapR3%28Idocs%29ToXI--Steps+Summarized&
Also can you check this weblogs on the same:
/people/swaroopa.vishwanath/blog/2007/01/22/ale-configuration-for-pushing-idocs-from-sap-to-xi
/people/venugopalarao.immadisetty/blog/2007/01/24/troubleshooting-file-to-idoc-scenario-in-xi
/people/michal.krawczyk2/blog/2005/03/29/xi-error--unable-to-convert-the-sender-service-to-an-ale-logical-system
/people/ravikumar.allampallam/blog/2005/02/23/configuration-steps-required-for-posting-idocsxi
/people/saravanakumar.kuppusamy2/blog/2005/01/20/configuration-tips-for-a-business-serviceintegration-process-to-send-back-ale-audit-idoc
---Satish -
HAI EVERYBODY,
PLEASE HELP ME TO FIND THE SOLUTION REGARDING "LOGICAL SYSTEM CHANGED" during the material master replication by using middleware parameters.
step1 : i have taken SRM client 810 and named it as CHINNISRM
step2 : i have taken r3 client 810 and named it as CHINNIR3
step3: During material master replication i maintained tables like crmconsum,crmrfcpar,crmparoltp in r3 and smofparsfa in srm client and filtered the objects and loaded the objects through r3ac3,r3ac1,r3as.
step4 : And later i have checked in r3 queues to activate the objects,but i have seen a message like "LOGICAL SYSTEM CHANGED:SEE 588701".according to the oss instructions i have checked in CRMPRLS table in se16 in R3 .there i found out there is one logical client named with T90CLNT810.
can anyone please give me the solution
thanks and regards
n,chakradharAlso u need to delete the entry with the old logical system name in TABLE CRMPRLS in MM.
Check SAP Note # 765018 -
Regarding "Error An SLD system has not been assigned to logical system "
Hi all,
I am trying to connect SRM system to an XI system. All the settings are done (or I thought so). When I try to send a PO via XML/XI to the XI system in SRM Web UI, it gives me the following error:
nformation Processing BBP_PO_SEND_XML Is Started
Error An SLD system has not been assigned to logical system
Error Action could not be successfully executed
The backend systems are defined in spro. When I debugged the coding, I find that the right Logical system itself is not picked up - is there any thing missed out?
Thanks,
VijayHi,
You should assign this here:
Supplier Relationship Management -> SRM Server -> Technical Basic Settings -> Define Backend Systems.
Here you should fill the "System Landscape Directory Name" for the systems you have defined.
Regards
Kathirvel -
Regarding problem while assigning logical system
Hi Friends,
I had a problem while assigning logical system to the client where in both of my systems are having same client number which belong to 2 different systems.
while assigning the sender and receiver logical system to the same client i am facing problem stating that an entry has already been made for the same key.
could any one plz give me a clear idea...while assigning logical systems (cross clients) for 2 different systems having same client number.
Regards,
MadhuHello Madhusree,
I'm running with same problem. I've created two logical systems and assigned them to two different clients. But here pops up the issue while generating partner profiles, throwing error "No active plan version exists". Later when I researched about the issue, I came to know that T77S0 table doesn't have any entries regarding plan versions. Basically, I created two clients by doing "client copy" from source client (800 & 100). And I could see plan version entries in the T77S0 of client 800. So, I thought of assigning just defined logical system to the source client 800 itself. But it throws error saying "entry already exists"; as client (800) is already assigned with other logical system.
By coming across your post, gives me leap of hope that two logical systems can be assigned to same client. Could you please share me those troubleshooting steps concerning this issue. Points will be awarded.
Regards, Anil. -
Regarding Error: Unable to Convert Sender System to ALE Logical System
Hi friends,
in File to IDoc scenario, i created a sender business system called bs_filetoidoc_send based on Standalone technical system and a receiver business system based on ABAP r/3 system. in my SAP IDES system which is dual stack (abap+java), XI client is 001 (LS: devclnt001) and r/3 client is 800 (LS: t90clnt090) i.e i'm posting idoc to t90clnt090.
I tried to send a text file. but while processing xml message in XI, i got an error saying "Unable to Convert Sender System to ALE Logical System".
then i searched the blogs and forum and found the solution. it was saying LS name was not assigned to BS bs_filetoidoc_send. so i went to SLD and tried to assign LS devclnt001 to my sender BS bs_filetoidoc_send, but got an error saying that "A business system with LS devclnt001 already exists". when i checked which is that BS, it is supposed to be the INTEGRATION SERVER itself with BS name INTEGRATION_SERVER_DEV.
then i configured my sender BS as INTEGRATION_SERVER_DEV itself which picked up the text file successfully and also receiver abap server received the IDOC with correct data and format with status 51. so scenario worked fine when i used my sender BS as INTEGRATION SERVER itself.
please clear my following doubts which arose after this scenario.
1) why the scenario didn't work when I used only standalone sender business system?
2) why should we assign a LS name of XI server to sender business system only in this scenario?
scenario worked according to my requirement, but using integration server itself as a sender BS confused though.
Many Thanks.1) I can create any no of LS names using SALE
Yes you can create.
> 2) But I can assign a client to any one of those LS names (or 1 client will have only one LS name associated with it)
One Client will have one LS associated to it...and that can be any one of the LS..created.. use SCC4 to find the associated Ls for all the clients of a system
3) So anyways INTEGRATION_SERVER_DEV has to associated with the client 001 only, so finally I have to use INTEGRATION_SERVER_DEV only as my sender BS. Probleum is that I can't remove the LS name DEVCLNT001 from INTEGRATION_SERVER_DEV and assign it to bs_filetoidoc_send BS right. If I do so, I think I would get an error saying that INTEGRATION_SERVER_DEV is not associated with the LS name of client 001.
As the logical system defined in Partner profile is expected to arrive in Control record of IDoc..it should be passed in that...
Did u checked this blog../people/rajeshkumar.pasupula/blog/2009/03/16/unable-to-convert-the-sender-service-to-an-ale-logical-system so as per you need the explaination in the blog need to associate the logical system name .
HTH
Rajesh -
Logical System in IDOC-XI scenario
Hi,
I need help to understand few things in IDOC-XI scenario, could any one help me in this regard.
we use Adapter specific identifiers to map services, we have following type of identifiers 1) Sys.ID & Client No. 2) Logical System.
my questions are
a) Are we use Logical System in B to B scenario ?
b) Are we use LS in reference to the SAP system or Non SAP system ? if a non SAP system....how a non SAP system send an IDOC and why a non SAP system receive an IDOC ( conversion is possible in XI ) ?
Thanks and Regards
Mahesh.Hay Kumar,
Logical systems can also be used for SAp sytems wich are not installed yet as a virtuall placeholder.
a) yes. if on of your business is a non sap system or a propritery system that you developed yuo'll ue LS.
b) non SAP system can send and recieve IDOCs. so it's possiable to get an IDOC from a system and turn it into an RFC for SAP or get an IDOC from an SAP system and then turn it into something else for another system.
Have a Good One,
Uri Lifshitz. -
An RFC destination could not be specified for the logical system
Hello Experts,
I am trying post goods receipt in EWM system in a simple inbound delivery process. It is not getting posted back in ECC. I have my RFC connection setup properly(I assume since I was able to transfer inbound delivery to EWM in first place).It seems some setting related to Outbound queue in EWM is missing.Can anyone tell me in detail what settings are required?Is it something to do with WE20 transaction?I am not sure what settings should be done there.The error log is as below-
An RFC destination could not be specified for the logical system
SB3CLNT011
Message No. B1550
Diagnosis
An RFC destination should be specified for the logical system SB3CLNT011.
This could not be done in this case. SB3CLNT011 is not your local logical system
and this system is not included in the relevant Customizing tables.
Procedure
Check:
RFC
destination
Port
definitions
oubound partner profile of
message type SYNCH for this logical system
Regards,
KhushbooHi Oritra and Suraj,
I have checked remote connection in SM59 for both the logical system.It works fine.I understand this is more of a technical issue,but I don't have A local basis team to help me so reaching out to experts here.Can you guide me what technical settings could be checked for EWM-->ECC connection?When I execute BD82 for SB3CLNT011 it shows me green status with message "No messages have been defined for the selection conditions in the model".
Although when I do this for EWM logical system SB3CLNT012 it shows me this with all green status-
System SB3CLNT011 as a partner type already exists
System SB3CLNT012 as a partner type already exists
Port A000000018 with RFC destination SB3CLNT011 already exists
Outbound parameters for message type SHP_IBDLV_CHANGE SHP_IBDLV_CHANGE01 already
Outbound parameters for message type SHP_IBDLV_SAVE_REPLICA SHP_IBDLV_SAVE_REPLI
Outbound parameters for message type SYNCH SYNCHRON already exist
Am I missing something in WE20?
Regards,
Khushboo -
Logical system name for acknowledgement in BPM
Hi,
I have a szenario:
IDOC --> BPM --> MAIL
Inside BPM I check the message and depending on an xml-element I stop the process or I send the message by mail.
When I stop the process the BPM sends back an acknowledgement and in SXMB_MONI I can see an error of the acknowledgement:
"Sender Test_BPM_IDOC_TO_MAIL kann nicht in ein ALE Logisches System umgeschlüsselt werden" (Sender can not convert in a ALE logical system)
What can I do?
Possible Solution 1:
I can define my BPM "Test_BPM_IDOC_TO_MAIL" as a logical system (including WE20 for ALEAUD).
Possible Solution 2:
I can enter an existing logical system name in the "adapter specific attributes".
BUT it is not use the same logical system name twice (BAD ... or is there a workaround?
Is Solution 1) a common way?
Thanx
Regards
Wolfgang HummelHi,
there are many ways:
some for aleaud are described in my book:
<a href="/people/michal.krawczyk2/blog/2006/10/11/xi-new-book-mastering-idoc-business-scenarios-with-sap-xi"><b>Mastering IDoc Business Scenarios with SAP XI</b></a>
>>>>Is Solution 1) a common way?
no this is not good a good idea
BTW
you can also supress aleaud raport IDX_NOALE
Regards,
michal
<a href="/people/michal.krawczyk2/blog/2005/06/28/xipi-faq-frequently-asked-questions"><b>XI / PI FAQ - Frequently Asked Questions</b></a> -
Logical System Name Not appearing in the Business System
Hi,
Initially we had created a Technical system with Client 700 without a "Logical System Name" in SLD. hence the 'logical system name' in 'business system' was also Blank.
Now, since we are implementing the IDOC to file scenario; we need to maintain the "Logical System Name" in the client and which in turn should reflect in our Business System in SLD.
Though we maintained the Logical System Name in the Technical System --> Client --> Logical System Name; we are unable to see the same(Logical System Name) in Business System ('Integration' tab)
Please also note that Business System is of the ROLE: Integration server.
When we go to business system in SLD ---Integrtaion tab ---Logical System Name -- is still blank.
Can anyone please help us to update the 'Logical system name' in Business System in SLD?
Regards,
RehanHi Sunil,
I followed your link till
Bussiness System -> select your bussiness System -> in Below pane u will find Details of your bussiness system ->amongs the various tabs available select Integration Tab->U will See option for technical system beside that u will see option for change ->click this ->u will be taken to Logical system ->there u define u r logical syatem name and then save the entries.
When I clicked the option chnage ---> "Change Associated Technical System" appeared, It didn't take me to Logical system.
But in turn I clicked hyperlink corresponding to Technical systems, it took me to technical system --> clients tab --I have entered the Logical system name.
When I go back to Business system again its not showing the Logical system name in Integration tab.
regards,
rehan
Maybe you are looking for
-
I downloaded opera mini for my phone and started downloading games from the opera store I played one of them When i exited it my phone shut down Now when i turn it on the tmobile or nokia image doesn't show up just a lil blue question mark I cant acc
-
Black spot on the center screen
Hi I have baught blackberry curve 9300 from Bahrain Airport last week.. now my berry shows a black spot on the center in 1.5 Cm lenght its visible when screen is dark but the white screen doesnt shows clearely. I am afraid whether any daamage happend
-
Easiest way to open CS 5.5 files in CS 5?
Does anyone happen to know if CS 5.5 users can save files back to CS 5? If so, how is that accomplished? Have their been any known issues?
-
Hi Experts, I am very much confused about t-code LS07, can you confirm me what is the actual use of LS07. Regards Ishu
-
OS: AIX 5.2 DB: 10g release Two Can any one share with me his experience to install Oracle Database on AIX? ** I will be thankful if you recommend any installation docs or url available for that. DN