Regarding message popup

hi experts,
i am updating the database table with the help of
pushbutton ,what i want that after pressing the
button a message will come out that "data for particular employee number 00000021
has been saved ,means in a  popup for message i want different employee number,
how will i pass different employee number while showing the message.
plz help me to sort out this problem......

Hi,
SE91 for message class, choose a message number with two& & minimum
Suppose if u have taken message number 200 from ZX message class.
Message i200(ZX) WITH text-001 itab-empno .
text-001 - data for particular employee number
In this way you can get the pop-up message with emp number.

Similar Messages

  • Message popup

    Is it possible, after the error message popup,
    a) I want to print out a message in the report after the flow completed. If yes, how would i do it?
    b) I had an existing interactive flow. After the message popup, i want the user to re-enter/change some of the parameters and only continue the flow. How would i do that?
    Thank you!

    Hi faithict,
    What error message popup are you getting?  Is it a TestStand error, or are you using a Message Popup step to create your own error message?
    What is the message that you want to add to the report?  Is it error message information, user entered information, step results, or something else?  You can find more information about adding results to a report here.
    Do you already have something in place that allows the user to set the parameters?  If so, you can probably call the same module to allow the parameters to be set again.
    Regards,
    Brandon V.
    Applications Engineering
    National Instruments
    www.ni.com/support

  • Message popup add more buttons than six

    Hi,
    On TestStand 4.2.1, I encounter a limit of 6 buttons. 
    How can I add more buttons ?
    Or, can I replace message popup by list ?
    Thank you 

    Hi,
    Have you thought of using LabVIEW to create something?
    I have attached a simple VI that you can pass an array of string data from TestStand to LabVIEW..
    Regards,
    Shane.
    Attachments:
    PopUp.vi ‏25 KB

  • Regarding Messages Display

    Hi..
    I am taking the LIFNR as input through Select-Options. In the LPS i'm displaying his purchase header details.
    If no purchse data exists for particular vendor...then Im diaplaying  one information message.
    But after clicking on message popup box....its going to LPS and displaying TOP-OF-page.
    How can I avoid TOP-OF-PAGE execution.
    I hope U understood my requirement.
    Regards
    Sandeep Reddy.

    Hi Sandeep,
    Write this message under <b>AT Selection-Screen</b> event.
    After that add <b>STOP</b>, it will work exit immediately.
    Hope it will solve your problem.
    Regards
    Krishnendu

  • Deal with teststand message popup

    when I add a message popup in my sequence,I need two button: Ok(button1) and Cancel(Button2).and set timeout.
    My question is like this; I need get the status when execute,if uesr click ok,the sequence should go to next step,the other stauts,the sequence should abort executing.
    example:
    Message Popup
    if(RunState.Sequence.Main["Message Popup"].Button1Label=="OK")
       call sequence   //this action need execute when click "OK"
    else
       break        //this is a action ,without any connection of message popup
    end
    but no matter what button I click ,the sequence always execute break,that's means the if condition can't get the status of message,where is my error.
    any one help me ,thanks very much

    duplicate post see the following link
    http://forums.ni.com/ni/board/message?board.id=330&message.id=21602&jump=true
    Regards
    Ray Farmer

  • How to open a message popup and keep the sequence running ?

    I have some steps in my sequence to initialize communication ports that takes a few seconds. As i have the trace off i want to display a message popup to tell the user that the sequence is doing the init. After the init steps are done i want to close the popup out of the sequence without pressing any button.
    Is there a possibility in TestStand to do this ?
    The normal Message popup stays until a key is pressed and even pauses the sequence while active.
    Thank for help.

    You could call your message popup in a subsequence as new execution and terminate this execution programmatically after your init steps have finished.
    In order to do this you have to specify (module) the sequence call step that calls your subsequence:
    -Multithreading and Remote Execution = Run in a New Execution
    -Settings: Initally Hidden and Tracing disable, Restartable, Close Window when done, Wait for Execution to complete: Do not wait, Process Model Option: Do not use a Process Model
    -Store an Object Reference to the New Execution in: e.g. Locals.ExecutionRef
    After your Init steps you insert a ActvieX/COM Action Step that terminates the new execution:
    -Object Reference: Locals.ExecutionRef
    -Automation Server: NI TestStand API 3.1
    -Object Class: Execution
    -Call Method or Access Property: Call Method
    -Method: Terminate
    This will terminate your new execution showing the message popup.

  • Regarding Messages to Job Log

    Hi,
    What is a Job Log.
    i have to write messages to job log.
    how to do this.
    how can i see that messages whether it is written or not.
    how it can be seen to the client/user.
    regards,
    kiran

    Hi Kiran
    Use 'write' to display the message in the job log.
    write : / log_message.
    Place this statement after the block of statements in your program where you want the message to be displayed in the log.
    You can see the job log in SM37 transaction.
    hope this helps you.
    regards
    Message was edited by:
            Sarah Bollavaram
    Message was edited by:
            Sarah Bollavaram

  • Is there a way to center the text on a message popup

    Looking for a way to center multiple lines of text on a Message Popup.

    sdrochek3 -
    The step type does not export any option to center text that it displays. If centering text is a requirement, you will need to create a custom dialog in your ADE of choice and display that instead.
    Scott Richardson
    National Instruments

  • HT204204 i tried to update to ios 8.2 on my iphone 5s when message popup to me now my iphone not working, please help i dont want to lose my data

    hi
    i tried to update to ios 8.2 on my iphone 5s when message popup to me now my iphone not working, please help i dont want to lose my data

    What is the exact text of the message you got? And did you not back up before you updated?

  • Adding a variable in a Message Popup

    Hi guys, how to get a local variable in a message Popup? I try "string text"+ Runstate.Caller.Locals.foo ... Coz runstate is while program is running, Caller is the calling step and then local variable.
    But this give an error. Where to access my local variables while running?

    First of all, it depends on the data type of the variable. String can be added "similar" to the way you described. Numeric and boolean has to be cast.
    Second, you seem to misunderstand the concept of the RunState-property. If you want to insert a local variable of the sequence you are currently running, the expression should be:
    "My Dialog Text " + Locals.<localname>
    Don't forget type casts if not working with string variables!
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • Message popup not appearing

    I created a dll that had a message popup (userint.h) using Cvi version 6 on Windows XP, then using the Cvi runtime module and everything was good. I am now using Windows 7 (32 bit) and the latest Cvi runtime module and the dll partly works, does not give any errors, but the message popup does not appear.
    My guess is the new Cvi runtime module maybe does not support the older message popup, but really dont know, could be the Windows version; anyone know about this?

    Hi,
    I don't believe MessagePopup has changed since CVI 3.0 as stated here: http://zone.ni.com/reference/en-XX/help/370051V-01/cvi/uiref/cvimessagepopup/
    I would recommend stripping it down to the barebones and see if you can get it functioning that way.

  • Control Buttons in message popup with Digital I/O

    In my Test system the   operator  can use only the Start Stop Quit buttons on the Panel.
    He  aint have any mouse
    That means I have to provide him wit all  the control power  thr' these 3 digital I/Ps
    There are many message popups in the SequentialModel.seq  file 
    The OPERATOR will  respond to them with the 3 H/W buttons.
    OK= Green
    Terminate = Red
    how can I assign my  Buttons to all  Popup messages on teststand Irrespective of their .(i.e handling them Individually) 

    My plan is to control the whole testsystem, with  Hardware buttons (On off S/Ws for Operator) (operator wont be using mouse- it takes timeto scroll & prod is slow).
    The H/W buttons r read thr   Labview. The file is a member function of the class that I call In teststand seq.
    I am trying to  read and respond to Teststand  dialogues thr'  the Operator Interface using these 3   buttons 

  • Excel 2007 Not allowing message popup when double clicking

    Hello,
    We have recently upgraded to Office 2007 and are using IP workbooks.  When a user gets the "messages available; double click to display" the message box is not popping up.  Does anyone know how to fix this issue?  Not sure if it is an excel issue or a BEx issue.
    Thanks,
    Cherie

    SAP Note 1299828 mentions that it has been fixed with BI Addon Support Package 9.
    SAP Note 1294382 - SAPBINews NW7.0 BI Add-On Frontend SP900 - GUI 7.10 says:
    Fixed in Bex Analyzer: "Message popup is not shown on double click in Excel 2007. Please read note 1299828."
    I have it installed now but it does NOT work either (for me)!
    At least in the global settings the option automatically popup messages works. Each action brings up the messages then.
    Cheers,
    Lars

  • Message popup timeout - time left

    Can we get from the sequence context the time left (or time elapsed) of a timeout enabled message popup.
    For example,
    If the message popup is set to timeout after 120 sec and the operator responded when there are 50sec left for the step to timeout,
    does any built-in variable have the value 50 (seconds left) or 70 (seconds elapsed)?
    I know there are workarounds like calling Seconds() function in pre- and post-expressions and taking the difference but I wonder if it is already implemented or not.
    Thanks.
    S. Eren BALCI
    www.aselsan.com.tr

    This information is not stored in the step properties.  It is possible to change the step type to get this information.  The source code for MessagePopup is included with TestStand at <TestStand>/Components/NI/StepTypes/MsgBox/ if you have Labwindows/CVI.
    Your suggestion of using Seconds() is much easier to implement and be accurate enough for your use cases.
    Allen P.
    NI

  • Can't edit the Message Popup in TestStand 3.5

    I'm using TestStand 3.5/Labview 8, and when I inserted a Message Popup in my sequence, I found that I'm unable to edit it.
    I started with a new sequence file, right click->Insert Step->Message Popup, then right clicked the message popup and select Edit Message Settings.  I then get the following error (see err1.jpg attachment for actual error popup):
         SeqEdit.exe
         Error in call to LoadPanelEx.
         Parent Panel Handle: 1
         UIR File Name: editmsg.uir
         Panel Resource ID: 1
         hInstance: 0x597F0000, D:\...\TestStand 3.5\Components\NI\StepTypes\MsgBox\msgbox.dll
         Error Code: -143
         ActiveX control error
    Then when I click OK in that error I get another error (see err2.jpg attachment for actual error popup):
    Sequence Editor
    Program Error.
    Error Code: -17001
    I verified that the msgbox.dll file exists, and from reading some posts on the forum thought it wasn't properly registered.  When I tried to register it using regsvr32 I got the following message:  "msgbox.dll was loaded, but the DllRegisterServer entry point was not found.  This file can not be registered."  See err3.jpg attachement for actual error popup.
    Any ideas what is going on here and what I need to do to correct it?
    Thanks,
    -Bill
    Attachments:
    err3.JPG ‏15 KB
    err1.JPG ‏20 KB
    err2.JPG ‏11 KB

    Unfortunately that didn't work.  I went to Start->Programs->National Instruments->TestStand 3.5->Operator Interfaces->LabWindows-CVI and got the following error message:
    Test Executive
    Error in call to LoadPanelEx
       Parent Panel Handle: 0
       UIR File Name: TestExec.uir
       Panel Resource ID: 4
       Hinstance: 0x00400000, D:\...\OperatorInterfaces\NI\Full-Featured\CVI\TestExec.exe
    Error Code: -143
    Active X control error
    The actual error window is attached.  Looks like my installation has other problems?  With the way our IT department operates, if there is a way to fix this without reinstalling, that would really be helpful... :-)
    Attachments:
    err4.JPG ‏20 KB

Maybe you are looking for

  • Your email address has changed or is invalid -iTunes won't let me change it

    Help. I've tried everything including logging a request with Apple iTunes support - through the usual means, filling out the online request form. Still to no avail. The story goes like this, I changed my ISP about three weeks ago. I'm pretty sure my

  • Looking for some BAPIs to do some simple things

    Hello I am looking for someone to help me identify some BAPI function modules that will get me what I need.  Here is the information that I need, if you are able to identify a function module I can use, please let me know: Identify if a quotation num

  • JDBC connector help

    Ok here we go, I want to work with MySQL and JSP from Dreamweaver . I installed TOMCAT 5.0 and everything is working fine. But... I can't connect to my MySQL. I have downloaded the connector from MySQL, Install it and here is my CLASSPATH : C:\Progra

  • Sun java Messaging Server queries

    Hi, We are currently evaluating Sun java Communication suite. There are some doubts we are having about the system. 1) How can an admin block incoming/ outgoing mail from the internet for a specified user or domain ? 2) how can an admin backup and re

  • Sounds like iPods aren't so hot.....

    From the discussions I've read on this site, it sounds like iPods (or other mp3 players) aren't the hot item everyone seems to think they are. I just got one (as a gift) and really like the concept, but all these glitches and required update download