Regarding RF screen
Hi,
Can u please give an idea about RF Screen. Am new to it.
Regards,
Vijay.
hi
good
Most corporations who implement an ERP system are confronted with the issue of how to simplify and streamline the logistics process utilizing radio frequency (RF) technology. For SAP R/3® users in particular, this issue has always been addressed by selecting and implementing a 3rd party RF Middleware system. Since SAP did not offer any type of RF solution, this became the only choice. In the latter part of 1999, SAP quietly introduced a product named SAPConsole to finally address the issue of supporting character-based RF devices from SAP R/3. The question that now needs to be answered is, What is SAPConsole and will it work for my application.
This guide will clear up the mystery about SAPConsole and describe the benefits and limitations when evaluating an SAPConsole Approach to RF Data Collection.
For RF SAPConsole to work companies will need, along with the SAPConsole implementation, to also implement a WLAN network using the appropriate technology, frequency, compatibility and so on. The SAPConsole consultant should be able to provide advice on this.
History of SAP Console
Several years ago SAP partnered and subsequently purchased OFEK-tech, an Israeli company specializing in Warehouse Management and Control. As SAP OFEK-tech, one of the main objectives of this new partnership was to develop native support for radio frequency (RF) devices for the SAP R/3 Warehouse Management Module.
Parallel to the OFEK-tech effort, SAP initiated a new more comprehensive Warehouse Management systems strategy starting with R/3 version 4.5 known collectively as the Logistics Execution System (LES). LES integrates the applications of Warehouse Management, Shipping and Transportation, and can operate in an integrated mode similar to all the other modules (MM, PP, etc.) or as a stand-alone system (Decentralized WM).
These two initiatives finally came together starting with LES in version 4.6B. The new RF solution for LES offers several new Mobile Data Entry transactions specifically designed for RF users and the supporting operations. This whole suite of functionality including business transactions, configuration, and RF device support is sometimes mistakenly referred to as SAPConsole, since it was first released with version 4.6B. Technically, it is more correct to call this RF solution the SAPConsole Approach.
thanks
mrutyun^
Similar Messages
-
Can you giv me a brief introduction regarding selection screen with one eg:
Hello
can you giv me a brief introduction regarding selection screen with one eg:Hi Ranjith,
Selection Screens
Selection screens are one of the three types of screen in the R/3 System, along with dialog screens and lists. You use them whenever you want the user to enter either a single value for a field or fields, or to enter selection criteria.
Function
ABAP programs use screens to obtain input from users. The most general type of screen is a dialog screen, which you create using the ABAP Workbench tools Screen Painter and Menu Painter These tools allow you to create screens for data input and output. However, each of these screens requires its own flow logic.
Defining and Calling Selection Screens
You often use screens purely for data input . In these cases, you can use a selection screen. Selection screens provide a standardized user interface in the R/3 System. Users can enter both single values and complex selections. Input parameters are primarily used to control the program flow, while users can enter selection criteria to restrict the amount of data read from the database. You can create and save predefined sets of input values in the ABAP Editor for any selection screen. These are called variants. Texts on the selection screen are stored as language-specific selection texts in the program text elements. If you start an executable report using the SUBMIT statement, the input fields of the selection screen also serve as a data interface.
Defining and Calling Selection Screens
You define selection screens using ABAP statements in a program. Simple statements allow you to create input fields, checkboxes, and radio buttons, and design the screen layout. If you want to create a screen exclusively for data input, you do not need to create it using the normal dialog programming tools. When you create a selection screen, the system automatically assumes the tasks of the Screen Painter and Menu Painter.
The rules for calling and defining selection screens in ABAP programs depend on the program type:
· Executable program (type 1) without logical database
You can use a single standard selection screen and as many user-defined selection screens as you wish. The standard selection screen is called automatically when you start the program. User-defined selection screens, on the other hand, are called using the CALL SELECTION-SCREEN statement in a program. The standard selection screen always has the screen number 1000. User-defined selection screens can have any screen number except 1000.
· Executable program (type 1) with logical database
The standard selection screen for an executable program linked to a logical database is made up of the logical database selections and the program selections.
· Module pools (type M) and function modules (type F)
You can only use user-defined selection screens in module pools and function modules. These can have any number apart from 1000. You can only call a selection screen from a function module using the CALL SELECTION-SCREEN statement. You can also define selection screens as Subscreens and incorporate them in screens or tabstrip controls.
Hope this is useful.
regards
Ram
Message was edited by:
Ramanujan Chitrakootam -
Regarding Safari; (screen goes crazy when I press the Top Sites bottom)
Regarding Safari; When I open safari everything works fine, but when I press the top sites bottom, the screen goes crazy for a second and then goes to the top sites. It is not fading or dimming from one screen to the other like it use to do. any sugestions. Thanks
Nope, it isn't normal, but I don't know the cause. You might have better luck posting in the Safari forum:
https://discussions.apple.com/community/mac_os/safari -
Regarding selection screen output
hi,
i have created ALV report by using selection screen.in this i have displayed kunnr field from kna1 table.
but it is showing someextra zero's and then code now i want to display only code not extra zero.here below i am giving example:----
sap code
00001562
but i want like this....
sap code
1562.
thanx/regards,
vaneet thakurTABLES : VBRK,KNA1.
TYPE-POOLS : SLIS.
DATA : T_FIELDCAT TYPE SLIS_T_FIELDCAT_ALV,
L_FIELDCAT TYPE SLIS_FIELDCAT_ALV, "DECLARATION OF FIELDCAT FOR OUTPUT DISPLAY
T_LAYOUT TYPE SLIS_LAYOUT_ALV.
DATA : BEGIN OF ITAB OCCURS 0,
VBELN LIKE VBRK-VBELN, "PO NUMBER
VTEG LIKE VBRK-VTWEG, "DC
SPART LIKE VBRK-SPART, "DIVISION
FKDAT LIKE VBRK-FKDAT, "DATE
KUNRG LIKE VBRK-KUNRG, "CUSTOMER PLANT
WERKS LIKE VBRK-WAERK, "SITE
VKORG LIKE VBRK-VKORG, "SALE ORGANIZATION
NAME1 LIKE KNA1-NAME1,
ORT01 LIKE KNA1-ORT01,
END OF ITAB.
SELECTION-SCREEN : BEGIN OF BLOCK VANEET WITH FRAME TITLE TEXT-001.
*SELECT-OPTIONS : SITE FOR VBRK-WAERK.
SELECT-OPTIONS : PCODE FOR VBRK-KUNRG.
*SELECT-OPTIONS : INVOICE FOR VBRK-VBELN.
SELECT-OPTIONS : S_ORG FOR VBRK-VKORG OBLIGATORY.
SELECT-OPTIONS : DC FOR VBRK-VTWEG OBLIGATORY.
SELECT-OPTIONS : DIVISION FOR VBRK-SPART obligatory.
*SELECT-OPTIONS : PO_DATE FOR VBRK-FKDAT.
SELECTION-SCREEN : END OF BLOCK VANEET.
SELECTION-SCREEN : BEGIN OF BLOCK VANEET1 WITH FRAME TITLE TEXT-002.
SELECT-OPTIONS : INVOICE FOR VBRK-VBELN.
SELECT-OPTIONS : PO_DATE FOR VBRK-FKDAT.
SELECTION-SCREEN : END OF BLOCK VANEET1.
*PERFORM TOP-OF-PAGE.
PERFORM FETCH-DATA.
*PERFORM DISP_DATA.
PERFORM T_FIELDCAT.
PERFORM REUSE_ALV.
**& Form TOP-OF-PAGE
text
--> p1 text
<-- p2 text
*FORM TOP-OF-PAGE .
*FORMAT COLOR 3 INTENSIFIED OFF.
*FORMAT COLOR 5 INTENSIFIED OFF.
*write : /48(120) 'NAHAR RETAIL LTD'.
*FORMAT COLOR 3 INTENSIFIED OFF.
*write : /48(120) 'FOCAL POINT'.
*FORMAT COLOR 6 INTENSIFIED OFF.
*write : /48(120) 'LUDHIANA'.
*write : / sy-uline.
*format color 4.
**WRITE: /1(20) 'INVOICENO',
25(15) 'SAP CODE',
55(15) 'PARTYNAME',
100(50) 'LOCATION'.
format color 7 INTENSIFIED ON.
*ENDFORM. " TOP-OF-PAGE
*& Form FETCH-DATA
text
--> p1 text
<-- p2 text
FORM FETCH-DATA .
REFRESH ITAB.
SELECT AVBELN AKUNRG AFKDAT AWAERK BNAME1 BORT01 INTO CORRESPONDING FIELDS OF TABLE ITAB
FROM VBRK AS A INNER JOIN KNA1 AS B
ON AKUNRG = BKUNNR
WHERE
A~VBELN IN INVOICE
and
A~FKDAT IN PO_DATE
and
B~KUNNR IN PCODE
GROUP BY AVBELN AKUNRG BNAME1 BORT01 AFKDAT AWAERK.
SORT ITAB ascending BY VBELN.
*ENDSELECT.
ENDFORM. " FETCH-DATA
**& Form DISP_DATA
text
--> p1 text
<-- p2 text
*FORM DISP_DATA .
*loop at itab.
*write :/1(18) itab-VBELN,
27(5) ITAB-KUNRG,
55(25) ITAB-NAME1,
100(50) ITAB-ORT01.
*endloop.
*ENDFORM. " DISP_DATA
*& Form T_FIELDCAT
text
--> p1 text
<-- p2 text
FORM T_FIELDCAT .
PERFORM fill_field USING 'VBELN' 'PO NO'.
PERFORM fill_field USING 'KUNRG' 'CUSTOMER PLANT'.
PERFORM fill_field USING 'NAME1' 'PARTY NAME'.
PERFORM fill_field USING 'ORT01' 'LOCATION'.
PERFORM fill_field USING 'BASME' 'UOM'.
PERFORM SELECTION_WIDTH.
ENDFORM. " T_FIELDCAT
*& Form fill_field
text
-->P_0267 text
-->P_0268 text
FORM fill_field USING p_fieldname
p_seltext.
L_FIELDCAT-FIELDNAME = p_fieldname.
L_FIELDCAT-TABNAME = 'ITAB'.
L_FIELDCAT-SELTEXT_M = p_seltext.
L_FIELDCAT-OUTPUTLEN = 10.
APPEND L_FIELDCAT TO T_FIELDCAT.
CLEAR L_FIELDCAT.
ENDFORM. " fill_field
*& Form REUSE_ALV
text
--> p1 text
<-- p2 text
FORM REUSE_ALV .
CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
EXPORTING
I_INTERFACE_CHECK = ' '
I_BYPASSING_BUFFER = ' '
I_BUFFER_ACTIVE = ' '
I_CALLBACK_PROGRAM = ' '
I_CALLBACK_PF_STATUS_SET = ' '
I_CALLBACK_USER_COMMAND = ' '
I_CALLBACK_TOP_OF_PAGE = ' '
I_CALLBACK_HTML_TOP_OF_PAGE = ' '
I_CALLBACK_HTML_END_OF_LIST = ' '
I_STRUCTURE_NAME =
I_BACKGROUND_ID = ' '
I_GRID_TITLE =
I_GRID_SETTINGS =
IS_LAYOUT = T_LAYOUT
IT_FIELDCAT = T_FIELDCAT
IT_EXCLUDING =
IT_SPECIAL_GROUPS =
IT_SORT =
IT_FILTER =
IS_SEL_HIDE =
I_DEFAULT = 'X'
I_SAVE = ' '
IS_VARIANT =
IT_EVENTS =
IT_EVENT_EXIT =
IS_PRINT =
IS_REPREP_ID =
I_SCREEN_START_COLUMN = 0
I_SCREEN_START_LINE = 0
I_SCREEN_END_COLUMN = 0
I_SCREEN_END_LINE = 0
I_HTML_HEIGHT_TOP = 0
I_HTML_HEIGHT_END = 0
IT_ALV_GRAPHICS =
IT_HYPERLINK =
IT_ADD_FIELDCAT =
IT_EXCEPT_QINFO =
IR_SALV_FULLSCREEN_ADAPTER =
IMPORTING
E_EXIT_CAUSED_BY_CALLER =
ES_EXIT_CAUSED_BY_USER =
TABLES
T_OUTTAB = ITAB
EXCEPTIONS
PROGRAM_ERROR = 1
OTHERS = 2
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
ENDFORM. " REUSE_ALV
*& Form SELECTION_WIDTH
text
--> p1 text
<-- p2 text
FORM SELECTION_WIDTH .
CALL FUNCTION 'CONVERSION_EXIT_ALPHA_INPUT'
EXPORTING
INPUT = itab-kunrg
IMPORTING
OUTPUT = itab-kunrg -
Regarding Selection-Screen Field Display
Hi All,
I have issues with Selection-Screen field display.
The Actual issue is i had declared a selection screen field as: <b>s_exgen FOR embk-exgen</b>.
<b>EMBK-EXGEN</b> is actually <b>20</b> Char length field.
But in output display it is being shown as <b>18</b> Char field though i can type in all <b>20</b> characters.
But <b>display</b> restricted to <b>18</b> Characters only.
Can anybody give me the solution for the same!
Thanks in advance.
Thanks & Regards,
Prasad.Hi,
You can decrease the visible length of the field but you can not increase more than database field length. check SAP help on this :
select-options: s_exgen FOR embk-exgen VISIBLE LENGTH 5.
... VISIBLE LENGTH vlen
Effect
This addition allows you to shorten the visible length of the corresponding screen field on the selection screen to vlen.
Variant 2
SELECT-OPTIONS sel FOR (f).
Additions as in variant 1.
Effect
In this variant, (f) must be a field containing the name of the actual reference field at runtime. The system creates the LOW and HIGH fields as character fields with length 45. However, their appearance on the selection <b>screen is inherited from the reference field whose name is contained in field f at runtime.</b>
Regards
Appana -
Query regarding selection screen
Hi experts,
I have a requirement that once I get my output on a selection screen, suppose it has just 1 row and 4 columns. If I click on each of these 4 columns, a new transaction/report etc. needs to be called. How can I achieve this functionality?
Thanks,
Ajay.Hi,
Say you have an internal table with fields as:
VBELN (sales order)
POSNR (sales order line item)
WERKS (plant)
MATNR (matnr)
And you write all these fields on output screen using reporting and when you click on any column field then a particular transaction/report should be called, then follow the below mentioned logic:-
DATA : BEGIN OF it_final OCCURS 0,
vbeln TYPE vbap-vbeln,
posnr TYPE vbap-posnr,
werks TYPE vbap-werks,
matnr TYPE vbap-matnr,
END OF it_final.
DATA : fldname(25) TYPE c,
fldvalue(25) TYPE c.
START-OF-SELECTION.
"select query into it_final internal table
AT LINE-SELECTION.
GET CURSOR FIELD fldname VALUE fldvalue.
CASE fldname.
WHEN 'IT_FINAL-VBELN'.
WRITE : / fldvalue.
"code to call transaction/report
WHEN 'IT_FINAL-POSNR'.
WRITE : / fldvalue.
"code to call transaction/report
WHEN 'IT_FINAL-WERKS'.
WRITE : / fldvalue.
"code to call transaction/report
WHEN 'IT_FINAL-MATNR'.
WRITE : / fldvalue.
"code to call transaction/report
ENDCASE.
END-OF-SELECTION.
ULINE.
FORMAT HOTSPOT.
LOOP AT it_final.
WRITE : /1 it_final-vbeln, 10 it_final-posnr, 20 it_final-werks, 30 it_final-matnr.
HIDE : it_final-vbeln, it_final-posnr, it_final-werks, it_final-matnr.
ENDLOOP.
ULINE.
Now to call a transaction user:-
SET PARAMETER ID '<param_id>' FIELD '<field_value>'.
CALL TRANSACTION '<t_code>' AND SKIP FIRST SCREEN.
To call a report use:-
SUBMIT <report_name> WITH <parameter_name1> = <field_value1>
WITH <parameter_name2> = <field_value2>
"and so on use parameters
AND RETURN.
<paramater_name> refer to the parameter of the called report <report_name>
and <field_value> refer to value for the parameter to be passed.
Hope this helps you.
Regards,
Tarun -
Regarding the screen problem in 'back' command
Hi Experts,
I am doing project on data scrambling an using the ldb PNP . currently i am facing one problem regarding the' BACK'.
i am calling one screen program in main program. when i am clicking on back button from screen program ,the control flow back to the main program and the rest of the lines of the main program gets executed.
i want the control must go back to the default selection screen.
i have tried using leave to screen 0,leave program and exit.But these command are not working as per the requirement.
thanks in advance.Hai,
Please check the fct code for BACK button. if the fctcode is exist then use the following code.
if sy-ucomm = 'BACK'. " USE CAPITAL LETTERS ONLY
LEAVE TO SCREEN 0. -
Regarding slection-screen problem
Hi,
I have one requirement in selection-screen.if I enter the period from 04 to 03 with fiscal year from 2006 to 2007 as in put parameters in selection-screen, getting error message as 'From period is greater than To period'.
Can any body please respond to my question..
Regards,
Suresh Kumar.Say you have the selection fields
SELECTION-SCREEN BEGIN OF BLOCK block
[WITH FRAME [TITLE title]]
[NO INTERVALS].
parameters: per1 fiscyr1 per2 fiscyr2
SELECTION-SCREEN END OF BLOCK block.
SELECTION-SCREEN END OF BLOCK block.
AT SELECTION SCREEN ON BLOCK block.
data: num1 type n, num2 type n.
CONCATENATE fiscyr1 per1 into num1.
CONCATENATE fiscyr1 per1 into num2.
if num1 > num2.
message: from period greater than to period
endif. -
Regarding Selection Screen in smartforms
Hi:
I got the following requirement.
I've to make a smartform & do the coding in smartform itself. I'm not sure that how to populate a selection screen. I need to populate a Select-options. Please help me out.HI,
You can create the Selection screen in a program and call the Smartform function module in the Program and you can pass the Selection screen parameters to the Smartfor, if you create the Fields in FROM INTERFACE in Smartfroms, then that become import paramters in the function module and you can pass the selection screen fields to this paramters
Look at the below link, it is having the Program and the Progam using the select-options also
http://www.erpgenie.com/abap/smartforms.htm
Regards
Sudheer -
Regarding Sub Screen Moving problem
Dear All,
I created 9 subscreen and assigned to different tabs.
Each and every sub screen have 3 to 4 text blocks (i.e. Custom Controls).
after moving one tab to another tab scroll the sub screen down , all text blocks also moving with scroll bar.
how to resolve this problem. Due to this problem saving also not working..when text blocks are study text save in ibject id and text id..But when moving saving not happend.
Regards,
Reddy NaraHai,
Please check the fct code for BACK button. if the fctcode is exist then use the following code.
if sy-ucomm = 'BACK'. " USE CAPITAL LETTERS ONLY
LEAVE TO SCREEN 0. -
Query regarding selection screen layout
i want to knw how to put a blank line / how to skip a line in selection screen...
like
in Block 1
Presentn filepath
Application filepath
(1 line skipped)
Log filepath
end of block 1Hi ,
use <b>SELECTION-SCREEN SKIP 2</b>. statement.If u want to skip two lines .
check this code.
selection-screen begin of block B1 with frame title text-d01.
selection-screen SKIP 3.
parameters : p_lifnr type lifnr.
parameters : p_kunnr type kunnr.
parameters : p_count(2) type n.
selection-screen SKIP 3.
selection-screen end of block B1.
regards
reena -
Regarding selction screen values
Hi ,
In my report there are two parameter
1. country
2.airport code
when i enetred country , then the airport will display the corresponding airports and description only,
there is a table where i get the country , airports and descriptions,
Please suggest how to solve this
regards,
krishnaHi,
as per my understanding you have to provide the F4 help for airport based on the country code entered, if my guess is correct follow the below procedure.
write the code in "at selection-screen on value-request for airport"
1) use the function module "DYNP_VALUES_READ" function module to capture the country entered on the selection screen.
2) select the airports based on the country code entered.
3) us the function moduel "F4IF_INT_TABLE_VALUE_REQUEST" to display the airport list in list of possible window.
Refer the below code you will understand.
here i am taking material and material description, based on the entered material i am fetching the material description on F4 help.
TABLES: mara.
DATA:
BEGIN OF x_matnr OCCURS 0,
matnr LIKE mara-matnr,
maktx like makt-maktx,
END OF x_matnr.
DATA:
l_dynprofld TYPE help_info-dynprofld,
l_matnr(7) TYPE c VALUE 'P_MATNR',
l_prog TYPE sy-repid,
l_dynnr TYPE sy-dynnr.
PARAMETERS: p_matnr LIKE mara-matnr,
p_maktx like makt-maktx.
AT SELECTION-SCREEN ON VALUE-REQUEST FOR p_maktx.
PERFORM f_get_values.
FORM f_get_values.
DATA: i_return LIKE ddshretval OCCURS 0,
i_dynpfields like DYNPREAD occurs 0 with header line,
l_repid like sy-repid.
l_repid = sy-repid.
i_dynpfields-fieldname = 'P_MATNR'.
APPEND I_DYNPFIELDS.
CALL FUNCTION 'DYNP_VALUES_READ'
EXPORTING
dyname = l_repid
dynumb = '1000'
tables
dynpfields = i_dynpfields .
IF sy-subrc = 0.
READ TABLE I_DYNPfields INDEX 1.
IF SY-SUBRC = 0.
CALL FUNCTION 'CONVERSION_EXIT_MATN2_INPUT'
EXPORTING
input = I_DYNPfields-FIELDVALUE
IMPORTING
OUTPUT = I_DYNPfields-FIELDVALUE.
select matnr maktx from makt into table x_matnr
where matnr = I_DYNPfields-FIELDVALUE.
ENDIF.
ENDIF.
IF NOT X_MATNR[] IS INITIAL.
l_prog = sy-repid.
l_dynnr = sy-dynnr.
l_dynprofld = l_matnr.
CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
EXPORTING
retfield = 'MAKTX'
dynpprog = l_prog
dynpnr = l_dynnr
dynprofield = l_dynprofld
value_org = 'S'
TABLES
value_tab = x_matnr
return_tab = i_return.
IF sy-subrc NE 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
ENDIF.
ENDFORM. " F_GET_VALUES
Reward if useful.
Thanks,
Sreeram.
Edited by: Sreeram Prasad on Jan 3, 2008 11:38 AM
Edited by: Sreeram Prasad on Jan 3, 2008 11:39 AM -
Hi,
I am using ADFBC.
I am developing search screen.when page loading all the recored are displayed initially as table.I want to hide this table when page loading.when submit button clicked then show the table.How can i do this?
Thanks,Hi
Go through the link given below :
How to create a search help for my own fields in selection screen
F4 search help on report selection screen
also try :
CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
EXPORTING
DDIC_STRUCTURE = ' '
RETFIELD = 'VKORG'
PVALKEY = ' '
DYNPPROG = SY-REPID
DYNPNR = SY-DYNNR
DYNPROFIELD = 'P_VKORG'
STEPL = 0
WINDOW_TITLE =
VALUE = ' '
VALUE_ORG = 'C'
TABLES
VALUE_TAB = T_TABLE1
FIELD_TAB = field_tab
RETURN_TAB = RET_TAB
DYNPFLD_MAPPING = DYN_TAB
EXCEPTIONS
PARAMETER_ERROR = 1
NO_VALUES_FOUND = 2
OTHERS = 3
With Regards
Nikunj shah -
hi,
how to increase the size of the screen horizontally and vertically while creating the screen.Hi,
For report program you can use the skip command in ABAP code to increase the length vertically..
For module pool you can use the screen painter..
regards,
mahantesh -
Regarding selection screen fields
hi gurus,
i have to show three city names like delhi,bombay n cuttack in selection screen one field under one ball symbol so that when the user click on this ball the three city name will appear and the user select any one out of these three names,which method will i use plz help me ,,,i m working on module poolsorry i am not enough clear with your requirement..
you can a give a pushbutton with the symbol and assign fncode for that.
now in a int table take the three city values.
in your PAI
case ok_code.
when 'BALL'.
call fn module POPUP_WITH_TABLE_DISPLAY_OK
or
POPUP_WITH_TABLE_DISPLAY
or
POPUP_WITH_TABLE
and pass your int table.
endcase.
regards
shiba dutta
Maybe you are looking for
-
Connecting a Local Java Program with a Mysql Database Hosted on the Interne
I need help. I want to connect a java program running on local user computers to read and write to a mysql database hosted in my domain by an internet service provider. What code do i use? How do i connect?
-
Volume higher level in Vista than OSX?
Hi everyone, this isn't a major issue but I'm really wondering why does my integrated speakers goes to an much higher level with windows vista than with OSX??? It's the same hardware and so should have the same sound level on both os... and it's not
-
I have Nokia 6300 and I don't have serbian language in it, language I speak. I don't have a problem with that, use english, but I do have a problem becouse characters like č, ć, ž, š, are not supported. Word like Čačak I have to type Cacak !?! Is the
-
The latest version of java?
What is offically the latest release version of java? It seems that sun has recently been pushing more to consolidate all the locations an end user can get the "latest version" of java. As recently as a few months ago different entry points from sear
-
why access such a small database can provide cross tab query facility and not by oracle, if somebody knows the real and flexible method of doing this plz be informs us.I will be highly oblized thanks