Regarding RFC Channel

hi ,
    to all the experts of XI .
i need a suggestion on using the RFC channel .
is is feasible to use single RFC channel for 10 Different Scenarios ...
i tried doing that but then at any point in time for any particular scenario my RFC channel starts giving me error ............
so i need u people  suggestion on whether to go for different RFC channel in every scenario or use the same one  .
With Regards
Bhawarlal Choudhary

Hi,
I think you can use same communication channel for more n more scenarios.
Currently, we are following same approach in our project. till now we didn't got any kind of errors for the same.
We are re-use our Idoc( receiver) and RFC( sender/ receiver) channels.
So, you can re use them.
Cheers.,
Stallin

Similar Messages

  • Regarding RFC Sender Communication Channel

    Hi All,
      I am working on RFC sender channel, need some important information.
    1). Can i use single RFC Sender Channel in Multiple Sender Agreements.
    2). Can i use Program ID in Multiple Sender RFC Channels. I am having one RFC to File interface and another  RFC to JDBC interface.
         Do i need to create 2 sender channels and 2 RFC destinations with 2 Program Ids????.
    Please give me clarifications.
    Regards,
    Balu

    If i will use single sender RFC channel and Single Program ID for my all sender agreements, how that Single RFC channel
    will identify the information like
    In our sender agreement we configure not only the channel but also the Sender Interface (in your case RFC)......this is the factor which defines what to accept......in broader term we use the same concept of channel re-use in other cases also and the same work fine because of this Sender Interface.
    I found Q28 interesting: https://service.sap.com/sap/support/notes/730870
    In first read it may sound confusing...but after some more rreads you will know what the answer means in the SAP note.
    Regards,
    Abhishek.

  • Getting the following error in receiver RFC channel

    Hi Folks,
    Iam having two RFC channels one as SENDER and other as RECEIVER.Ensuring that all the required data is perfectly given while creating these two channels...the SENDER RFC channel status is green in channel monitoring and RECEIVER RFC channel is red!
    Iam gettiing follwing error against RECEIVER RFC channel -
    <b>"Receiver channel 'Receiver_RFC' for party '', service 'BXT_100_IS'
    Error can not instantiate RfcPool caused by:
    com.sap.aii.adapter.rfc.RfcAdapterException: error initializing RfcClientPool:com.sap.aii.adapter.rfc.core.repository.RfcRepositoryException: can not connect to destination system due to: com.sap.mw.jco.JCO$Exception: (103) RFC_ERROR_LOGON_FAILURE: Name or password is incorrect. Please re-enter"</b>
    Even iam pretty sure about the user and pwd used in RECEIVER RFC channel...
    and also i noticed "perform notification" status is failed in cache notification against my user id...
    Can anyone help me in resolving this issue..
    Thanks in advance..
    Regards,
    Ram.

    Hi Ram,
    Please change your password to UPPERCASE and try.
    I have came across few instances where SAP converts passwords to uppercase while storing and so they dont match.
    Hope this helps.
    Regards,
    Rahul.

  • Regarding RFC Communication from SAP R/3 to SAP J2EE Engine 6.40

    Hello,
         We have an application deployed in SAP J2EE engine 6.20. From SAP R3 (SAP R/3 version is 6.4C), We are communicating to the application deployed in SAP J2EE Engine 6.20 using RFC protocol. EJB module (Deployed in SAP J2EE Engine 6.20) which is being invoked from a Function Module using RFC protocol has the same name as the Function Module name. We were able to communicate to SAP J2EE Engine 6.20 this way.
         Currently, I have deployed the same application in SAP J2EE Engine 6.40.  I have followed the same procedure which i have used while depolying and working with SAP J2EE Engine 6.20. But, it is not working, and i was not able to communicate to SAP J2EE 6.40, the same way i did in SAP J2EE Engine 6.20. 
       Please let me know whether the procedure for communicating to SAP J2EE Engine 6.40 has changed in comparison with SAP J2EE Engine 6.20.
    Also,Any pointers regarding RFC and JCO implementation in SAP J2EE Engine 6.40 willl be helpful.
    Thank you.
    Regards,
    -Shabir Rahim.

    Hello ,
          The Connection in sm59 is established successfully> there were no Error thorwn in SAP when testing the connnection. But when i am making background call using a Function Module in SAP R3, the calls reaches Application deployed in SAP J2EE Engine 6.40, But it is failing with the error as,
    #1.5#005056A24413003C000000240000126000042853BD899290#1170240034258#/System/Server##com.sap.engine.services.dsr####sstra902_IPC_2629150#Guest#6813e650a93f11dba9f5005056a24413#Thread[JCO.ServerThread-1,10,SAPEngine_System_Thread[impl:5]_Group]##0#0#Error#1#/System/Server#Plain####
    #1.5#005056A244130042000000000000126000042853CFDB80F8#1170240341655#/System/Server##com.sap.engine.services.dsr#Guest#2####322aaa71b11811db85e1005056a24413#SAPEngine_Application_Thread[impl:3]_36##0#0#Error#1#com.sap.engine.services.dsr#Java#DSR_36#com.sap.engine.services.dsr.res.DSRResourceBundle#Error while taking over external passport null#1#null#
    #1.5#005056A244130042000000030000126000042853CFDB86BD#1170240341671#/System/Server##com.sap.engine.services.jndi#Guest#2####322aaa71b11811db85e1005056a24413#SAPEngine_Application_Thread[impl:3]_36##0#0#Info#1#com.sap.engine.services.jndi#Plain###Incorrect name parameter rfcaccessejb//DCEUR/Z_AIS_IPC_CFG_PRICE in naming operation.#
    #1.5#005056A244130042000000040000126000042853CFDB8745#1170240341671#/System/Server##com.sap.engine.services.jndi#Guest#2####322aaa71b11811db85e1005056a24413#SAPEngine_Application_Thread[impl:3]_36##0#0#Info#1#com.sap.engine.services.jndi#Plain###Incorrect name parameter java:rfcaccessejb//DCEUR/Z_AIS_IPC_CFG_PRICE in naming operation.#
    #1.5#005056A24413003C000000280000126000042853CFDBC4AA#1170240341686#/System/Server##com.sap.engine.services.dsr####sstra902_IPC_2629150#Guest#6813e650a93f11dba9f5005056a24413#Thread[JCO.ServerThread-1,10,SAPEngine_System_Thread[impl:5]_Group]##0#0#Error#1#/System/Server#Plain####
    Here, //DCEUR/Z_AIS_IPC_CFG_PRICE is the Funcrtion module name in SAP R/3 6.4C.
    Also Please let me know whether is there any Operating Differences between WAS 6.20 and WAS 6.40, for JCO/RFC based Communication( ie Comunicating with WAS 6.40 from SAP r/3 using RFC Protocol). Any materials and Information on how to work on SAP J2EE Engine 6.4 will also be very helpful.
    Thank you.

  • RFC channel error

    Hi Experts,
    First time, transport objects form DEV to QTY server in SAP PI 7.31 dual stack.
    My scenario is RFC to JDBC. Activation is done, but when try to test RFC destination from ECC qty (which freshly created in ECC QTY) getting some error in sender channel.
    RFC destination error
    for Unicode test
    Any suggestion to resolve this issue?
    Thanks,
    Arthita

    Hi
    Two check if the program is registered go to SMGW.
    Go to --> Logged on clients.  Here must appear your PROG_ID
    If not, check authorizations to register external programs (RECINFO and SECINFO)
    Regards
    Javi

  • Regarding communication channel

    we will not create communication channel while
       using HTTP/Idoc Adapter. but why should we require comm channel while receiver is SAP system?

    Hi Praveen,
    IDoc Adapter resides on ABAP stack and hence can communicate directly with Integration Server, for the conversion from IDoc to IDoc XML.Communication Channel is used for communication with the Integration Server which is obtained directly in case of IDoc .Hence Sender idoc adapter is not required and therefore no Sender Agreement.
    In case of IDOC adapter as receiver to tell the XI where he should
    send the data - there are many systems to which we can connect our XI and somewhere there has to be an object which will tell thx XI "where to" -> which RFC destination should it use.
    Regards,
    Vinod.

  • Regarding RFC adapter

    Hi
        when we r using RFC adapter on sender side it asks fgor 'RFC  Program id' what we have to mention in it.
       Regards
      maheswararao

    Hi
    While creating the Communication channel using RFC adapter, you need to specify a Program ID , it can be any value. The same program ID u have to use when u are creating a RFC destination from your sender system to XI.
    With Regards
    K.Varadharajan
    Award points if it solves your problem

  • Regarding RFC to RFC Process

    Hi I want to configure the below scenario's
    First Process
    1) RFC->XI->RFC (In the beginning I need to receive the RFC from the sender and then do an RFC to the receiver)
    Second Process
    2) RFC->XI,  XI ->RFC,  XI->File.
    Do I need to Create Any Data Types?. What are all the mappings I need to Define, How many Interface Mappings required.
    Regards,
    Varun

    Hi,
    >>Moreover, I dont see any messages in Message Monitoring (SXMB_MONI) or in Runtime Workbench for the Sender and Receiver RFC Communication Channels.
    That means Your Process is itself Wrong.
    So please try to make sure that your RFc is carrying the data and sending to XI.
    For this u shld be able to see the message in XI's MONI.
    Make sure abt your RFC Triggering Process, then afterwards you can check in tables whether those are updated or not
    Regards
    Seshagiri

  • Regarding RFC connection in File to IDOC Scenario

    Hi everyone,
               I was configuring file to Idoc Scenario, i have made all the required configurations in SLD, IR and ID, in XI system and in R/3 System. i have created RFC connection from XI to R/3 system, and its working fine. i have created an Partner profile in WE20 with sender file system name with inbound parameters. <i>But still i am getting error as EDI Partner Profile not defined in WE05- iDOC ADDED WITH ERRORS. </i><b>Do we need to create an RFC connection from R/3 system to XI for file to Idoc Scenario</b>
         <b>!!! Note:  RFC connection from R/3 system to XI is not working, will this be a problem for file to idoc scenario. !!!</b>
    Regards,
    Varun Reddy.K

    Hi Varun
    Follow these steps
    First - Maintain the Sender R/3 System:
    SM59 : Create a RFC destination to XI
    WE21 : Create a TRFC Port ->Specify the RFC Destination Created
    BD54 : Create a Logical System for the Idoc Receiver
    WE20 : Create Partner Profile ->Maintain Outbound and the Inbound Parameters
    Second - Log on to XI System:
    SM59 : RFC Destination for Sender System
    IDX1 : Create the port to get Idoc Metadata from Sender System ( The Port Name must match the port name in the idoc header - Usually in format SAP<System ID>. eg. SAPID1 [Optional Step. Not mandatory]
    IDX2 : Maintain the Idoc Metadata. This is needed only by XI, and not by other SAP systems. IDX2 is needed because XI needs to construct IDoc-XML from the IDoc. No other SAP system needs to do that.
    Regards,
    Santosh

  • Query regarding RFC Call from R3 to BW

    Hi
    i have one scenario. during running the delta program in R3, and at the end of the code, send an RFC message to BW, which can trigger a job in BW which will start 1 meta chain.
    please let me know how this can be done and what ABAP code needs to be written there.
    Regards
    Atul

    Hi ,
    you can read  data related to  RFC connection  using sm59  with destination   for BW
    http://aq33.com/human-resources/Articles-006159.html
    http://it.toolbox.com/wiki/index.php/Re-Connect_R/3_and_BW
    we have done this   only  for .net  /BIZTALK  . so for BW you have to read ...
    regards
    Deepak.

  • Regarding Communication Channel Error in Component Monitoring(RWB) in Dev

    Hi,
    In my XI dev Server when I check Component monitoring....Adapter Engine and CC monitoring are showing errors ( showing red
    symbol)......
    I think my RFC to File Scenario cannot be executed  due to this.......I cant receive any messages in SXMB_MONI.....
    Please help me......
    Thanks,
    Sudheer

    Hi...
    Still I am not getting any messages in the MONI.....
    In communication Channel Monitoring it is showing green.......
    In Component Monitoring Integration Engine:XID showing red.....CCMS Status: showing red and Adapter Engine Showing red......
    Created RFC destination at ECC(of 'T' type) and gave ECC details....Then gave same details in Communication channel in XI.......
    I did not created RFC Destination at XI.......
    Should data to be passed to RFC or XI automatically pings the data......
    When ABAPer executed RFC Connection its successful...but when he executes Functional module i.e test it is showing 'SYSTEM_FAILURE'.....
    Thanks,
    Sudheer

  • Regarding RFC for SD n MM related to RFID

    hi all
    Will anybody give RFC for delivry of goods in Retail m using RFID technology
    Regards
    Abhijeet

    try to make use of Tcode BAPI
    or
    search in SE37 with search terms delivery.
    Regards
    Prabhu

  • Some PI questions regarding RFC and  receiver determination

    If we import the design objects in one customer system from another customer system , and in the original system there is an imported RFC ,
    This RFC has been created in the new SAP customer system.
    My question is do we have to import the RFC again , as it is already in the imported design objecs.
    My second question is , di we need to create a receiver determination for the answe in a synchronous send step of the BPM ,
    Thanks

    My question is do we have to import the RFC again , as it is already in the imported design objecs
    Yes....the RFC/ IDOC should be imported from the system to/ from which you will send/ receive the data.
    If the RFC was in system1 earlier and now in system2.....then you have to delete the RFC imported from system1 (if it is not used) and then import it from system2
    My second question is , di we need to create a receiver determination for the answe in a synchronous send step of the
    BPM ,
    Irrespective of sync/ async send step.....you should create Receiver Determination....which will have BPM as sender and the TO_SYSTEM as receiver.....not separately for response....just once
    Regards,
    Abhishek.

  • Regarding  RFC [ URGENT ]

    Hello Experts
    I am updating a table in SCM server with the data from R/3 tables. I am using RFC with destination.
    I created an FM[RFC] in R/3
    I created a program in SCM, in that i am calling that RFC.
    I created a dummy RFC in SCM with the same paramters.
    When i am executing the FM in R/3 i could able to fetch the data as output including some return value.
    But when i am executing the program which is calling the RFC i am not getting the data.
    But i am able to get the return value in R/3 FM[RFC]*
    So i am sure that logical destination name is working
    [ call  'FM' destination 'dest name' ].
    My problem is i am not getting the data to the SCM server eventhogh i could able to get data in R/3 and I could able to connect to remote server.
    *Guys Kindly let me know the solution for this it's a bit urgent
    thanks in advance
    Pramod

    Hi Pramod,
    In the RFC function place the code as infinate loop. like
    Data : x type c.
    do.
    if not x is initial.
    exit.
    endif.
    enddo.
    when you execute this the process will stop in this loop. Go to SM50 and select the process in debug mode. And in the debug mode you can change the value of x. then you can continue from that step in debug mode and you can trace.
    Regards
    Ganesh

  • Regarding RFC creation

    hi all,
    after creation of RFC,we have to release the RFC or not.
    regards,
    subba reddy

    Hi Subbareddy,
    Yes you have to release the RFC after compeltion of creation.
    After creation of RFC first import it into XI system and then test it once.If everything is working fine then you have to create a request for transporting this RFC from Dev system to QUALITY system.After creatiing the transport request then you can release the RFC with that transport request.With out releasing the RFC you can't move from Dev system to Quality system.
    Plz close this post if you got the answer.
    Regards,
    Raju.

Maybe you are looking for

  • Automatic Rule Determination Based on Service Order Type

    Hi Experts, I have a requirement to determine the rule based on the custom service order type. I have created 2 custom rules which are then assigned to 2 different org units as needed. Now the thing is i want to avoid putting condition step if else b

  • Need help with fillable pdf to be made into e-book format

    I have made a fillable pdf form using livecycle. I want this form to be used an an e-book. I have contacted kindle and they advised they can't a pdf file from me and it needs to be in html or microsoft word format. How can i convert my pdf form to a

  • IMovies in my 'Movies' folder don't appear in "Media Movies" in iDVD

    I am creating a DVD with 16 small iMovie files. They have been saved into the 'Movies' folder on my computer and play fine. When I am in iDVD, I can't add these movies. I have tried importing them from iDVD, they don't import. I have tried dragging t

  • Separate blend mode for each clone source

    If each clone source could have it's own blend mode (not to mention its own opacity and hardness) setting it would be more effective. The current blend mode setting in the clone source affects the preview only. I often have to jump back and forth bet

  • Song credit question

    Hi, I have a credit on my account for 1 song. If I purchase an album (songs are available for individual purchase) will the credit be applied to the overall album price? Any info is appreciated. Thanks